OSP FTTH TECHNICAL SPECIFICATION AERIAL INSTALLATIONS
1
Table of Contents
PAGE 1 PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 PAGE 12 PAGE 13 PAGE 14 PAGE 15 PAGE 16 PAGE 17 PAGE 18 PAGE 19 PAGE 20 PAGE 21 PAGE 22 PAGE 23 PAGE 24 PAGE 25 PAGE 26 PAGE 27 PAGE 28
General Information OSP FTTH PROJECT_1 General Information OSP FTTH PROJECT_2 General Information OSP FTTH PROJECT_3 Installation Underground To Aerial Temberang Sokong Temberang Tarik Pole Labeling Pole Installation Position On Pedestrian Area_1 Pole Installation Position On Pedestrian Area_2 Pole Installation Position On Pedestrian Area_3 Cable Installation Route ODC24 Installation On Pole ODP Installation On Pole Pole Color Installation Pole Specification Pole Installation Pole Installation Distance One Line Diagram Cable Synoptic Cable Core Management for Backbone and Feeder Optical Fiber Cable Specification Fiber Testing ODC72 Labeling ODP Labeling Inside ODC72 Labeling Inside ODC24 Installation ODC24 Labeling Standard Frame A3 As Plan Drawing For Vendor
1. Persamaan Terminology: - Feeder -> Fiber optic dari Sub Hub/OLT ke ODC - Distribution -> Fiber Optic dari ODC ke ODP - Drop Cable -> Fiber Optic dari ODP ke ONT 2. 1 ODP standard adalah untuk 8 rumah, untuk kavling/tanah kosong akan menggunakan core spare yang disediakan di ODP. 3. Untuk lebar jalan >12 meter jalan raya menggunakan tiang & ODP dimasing masing sisi jalan. 4. FO Feeder (OLT to ODC) jumlah core harus 264 core dengan design Planning MNC Kabel Mediakom. 5. Kabel yang digunakan untuk input 1 ODC adalah 48 core. 6. Dalam Gambar As Plan harus tergambar jelas info dan legend seperti format dibawah : Keterangan Gambar/Legend, Posisi ODC, ODP & Handhole, Jalur kabel serta jalur pembagian IKR (untuk Underground sampai As depan/antara 2 rumah), Nama ODP. 7. Kode ODC: Jenis ODC . Kode Kelurahan . Nama RW . No ODC . Contoh: ODC72.KYP.01.01 Penjelasan : ODC 72 untuk kelurahan Kayu putih RW.01, ODC yang pertama 8. Kode ODP: Kode Kelurahan . Nama RW . No ODC. No Spliter di ODC - No Output spliter di ODC. Contoh: KYP01.01.01.01 KYP01.01.01.01 Coding Increment untuk No.output Spliter di ODC (1 s/d 8) Coding Increment untuk No. Spliter ODC Ke_01 Coding Increment untuk No.ODC Ke_1 Coding Increment untuk Nama RW_01 Coding Increment untuk Lokasi kelurahan_(Kayu Putih)
Type ODC yang digunakan untuk jenis jaringan kabel udara adalah ODC 72 core. Type ODC yang digunakan untuk jenis jaringan kabel tanam adalah ODC 96 s/d 512 Core tergantung dari banyaknya homepass yang di layani.
GENERAL INFORMATION OSP FTTH PROJECT_1 PAGE 1
9. Seluruh core output spliter pada ODC yang menuju ke spliter distribusi ODP harus di terminasi di ODC dengan tidak lebih dari dua titik sambungan yaitu 1 di ODC (output spliter ODC) dan 1 lagi di input spliter pada ODP. Contoh: apabila ada 512 HP, menggunakan spliter pada ODC 1:8 sejumlah 8 unit dan 64 unit spliter pada ODP type 1:8 ODP per 8 rumah maka membutuhkan 8 + 64 = 72 spliter type 1:8 modular, dimana tiap spliter ODP terdapat 1 core yang diterminasi pada pigtail type SC/APC untuk input dan 64 core diterminasi pada output spliter OD C, sehingga total terminasi adalah 64 x 2 +12 (input ODC+sphare) = 140 core. 10. Apabila jumlah rumah yang akan dicover ODC melebihi 512 HP untuk type jaringan kabel udara, maka bisa propose menggunakan 2 ODC dalam 1 tempat atau titik berbeda tergantung dari design, atau pada type jaringan kabel tanam menggunakan type ODC yang lebih besar. 11. Type ukuran ODC yang digunakan disesuaikan dengan jumlah rumah yang dicover. 12. Lokasi ODC propose ditanah kosong dekat Gerbang masuk cluster/Pos security atau di area utilitas yang strategis. 13. Jenis Konektor dan adapter yang digunakan di ODC adalah type SC/APC 14. Pemasangan ODC atau ODP harus menghadap jalan. 15. Penamaan atau labeling pada box harus sama dengan kode ODC atau ODP 16. Basemap menggunakan warna grey, no rumah menggunakan warna hitam.
GENERAL INFORMATION OSP FTTH PROJECT_2 PAGE 2
Under Ground: 1. Pada jaringan Feeder setiap crossing harus ada Handhole ukuran 80 x 80 x 80 cm di kedua sisi. 2. Pada jaringan distribusi setiap ODC harus ada Handhole ukuran 60 X 60 x 60 cm. 3. Pada Jaringan distribusi setiap ODP harus ada Handhole ukuran 40 x 40 x 40 cm dan ditempatkan di batas persil rumah pada jalan. 4. Pada Jaringan distribusi setiap batas persil rumah per 2 rumah harus ada bak control dengan ukuran 20 x 20 x 20 cm, yang diperuntukan sebagai jalur IKR untuk 2 rumah dengan jalur pipa diameter 1 inchi menuju ODP,yang berbeda dengan jalur distribusi menggunakan HDPE. 5. Pada Jaringan distribusi pada crossing tidak diperlukan handhole kedua sisi (HDPE tanam langsung), kecuali ada jalur IKR. 6. Tidak diijinkan ada crossing didepan rumah, kecuali sudah terdapat existing handhole. Aerial: 1. Kabel yang digunakan adalah type Aerial/Kabel Udara/menggunakan type ADSS G652. 2. Untuk Feeder, setiap 5 tiang harus terdapat spare kabel dengan panjang 15 meter. 3. Jumlah kabel aerial dari ODC maksimal dalam 1 tiang adalah 5 kabel, apabila melebihi harus melalui underground sampai ke tiang dimana terdapat FAT. 4. Drop Cable dari tiang tidak boleh langsung melintang kearah rumah, melainkan harus menyusuri Distribution Cable kemudian baru berbelok didepan rumah menggunakan Q-Span. Messenger yang menempel di rumah juga diikat menggunakan screw eye hanger. 5. Pemasangan ODP adalah di Tiang, dimana posisi pemasangan tiang harus berdekatan atau bersebelahan dengan tiang PLN atau Telkom yang sudah ada serta harus dikordinasikan & mendapat persetujuan dari MKM dan pengelola kawasan.
GENERAL INFORMATION OSP FTTH PROJECT_3 PAGE 3
85
Slack Support
85
Spare In : 10 m Spare Out : 10 m
411
Stainless Steel Belt Buckle
Stainless Steel Belt Buckle
Handhole 40x40x40 cm
25
25
Berfungsi sebagai bak kontrol peralihan jalur
120
Pipa Galvanis 2 x 1,25 inch
Bellmouth
PERALIHAN JALUR KABEL TANAM KE KABEL UDARA SCALE : N.T.S
INSTALLATION UNDERGROUND TO AERIAL PAGE 4
137
63.5
137
101.6
Klem dobel 127.0
4"
700
Tiang Penahan
Fondasi, Beton 1:2:3 426
45
135
50
50
Muka Tanah
Dasar penahan fondasi : batu kali
TEMBERANG SOKONG PAGE 5
Kawat Baja
10 mm
Lapis HDPE Subduct 40 mm panjang 3 m Jepit / Klip Kabel
16mm, panjang 75 cm
200
Angkur galvanis
Muka Tanah
1500
Muka Tanah
750
TEMBERANG TARIK PAGE 6
format : ABC00.000 ABC - Nama Kelurahan, 00 - No. RW, . 000 - No.Tiang 1, mulai dari ODC, diurutkan sesuai jalur, kemudian dilanjutkan ke jalur berikutnya. Penomoran dilakukan per ODC dengan meneruskan urutan no. dari ODC sebelumnya.
PENULISAN LABEL TEGAK LURUS MENGHADAP KE ARAH ATAS. AWAL LABEL PADA 10 cm DARI SAMBUNGAN TIANG PERTAMA PELABELAN DILAKUKAN DENGAN CAT SEMPROT ATAU MENGGUNAKAN SPON
SAG17.1
5 cm 10 cm
10 cm
SAG17.1
5 cm
PELABELAN TIANG BERDASARKAN NO. TIANG YANG TERCANTUM PADA AS BUILT DRAWING. format = ABC00.000,
detil 1
UKURAN : LEBAR : 5 cm TIPE HURUF : ARIAL BLACK WARNA : PUTIH
detil 1
PEMBERIAN 2 RING BERWARNA BIRU LANGIT UKURAN : TEBAL RING & JARAK ANTAR RING : 2 CM JARAK DARI UJUNG BAWAH TIANG : 2 CM
2 cm 2 cm 2 cm 20 cm
14 cm
detil 2
2 cm 2 cm 2 cm 20 cm
14 cm
detil 2
PAVING BLOK
JALAN RAYA
POLE LABELING PAGE 7
63,5
1370
1370
63,5
101,6
1370
1370
101,6
127
JALAN RAYA
JALAN RAYA
PAVING BLOK
600
1350
600
1350
700
700
PAVING BLOK
500
TYPE SALURAN TERBUKA
500
TYPE SALURAN TERBUKA
4260
4260
7000
7000
127
POLE INSTALLATION POSITION ON PEDESTRIAN AREA PAGE 8
63,5
1370
1370
63,5
101,6
1370
1370
101,6
127
4260
4260
7000
7000
127
500 KERAMIK
1350
1350
600
700
JALAN RAYA TYPE SALURAN TERTUTUP
BETON
TYPE SALURAN TERTUTUP
JALAN RAYA
700
500
BETON
600
POLE INSTALLATION POSITION ON PEDESTRIAN AREA PAGE 9
penyebrangan kabel menggunakan tiang 9 m
pada tarikan lurus tanpa tracking messenger pada 2 gawang kabel antara 2 tiang yang di tracking. pemasangan accessories pada posisi antara 2 tiang yang messenger-nya di-tracking
Tiang 9 m
Tiang 9 m messenger
pada tarikan lurus tracking messenger per 3 gawang
pole strap 2,5 inch j-clamp buldog grip
kabel fiber optik
pemasangan accessories pada posisi tracking messenger
span wartel 16 mm
cable ties 45 cm
Tiang 7 m Tiang 7 m
Pedestrian
Pedestrian
JALAN RAYA
Pedestrian
Pedestrian
POLE INSTALLATION POSITION ON PEDESTRIAN AREA PAGE 10
CABLE INSTALLATION ROUTE PAGE 11
3
ODC24 Diletakkan berpunggungan pada tiang
Masing-masing ODC24 dipasang sesuai standar pemasangan ODP/FAT. Masing-masing diawali pemasangan slack support dengan panjang slack sekitar 15 m dan kemudian ODC diletakkan di atasnya.
ODC24 INSTALLATION ON POLE PAGE 12
300 850
Fixed Clamp
Suspension
Slack Support ODC+ODP Slack Kabel 15 m Kiri-Kanan
Slack Support
64,25
Slack Cabel 15 m Kiri-Kanan
ODP INSTALLATION ON POLE PAGE 13
30 cm 200 cm 200 cm
30 cm
137 cm
TIANG 9 m 137 cm
TIANG 7 m
Tiang seluruhnya dicat dengan cat dasar, dilanjutkan dengan cat semprot warna hitam. 900 cm
426 cm
Merk Cat Nippon Paint
Cara pengecatan semprot
500 cm
Cara pengecatan semprot
700 cm
Tiang seluruhnya dicat dengan cat dasar, dilanjutkan dengan cat semprot warna hitam.
Merk Cat Nippon Paint
POLE COLOUR INSTALLATION PAGE 14
TIANG 9 M
pasak
pasak
OD= 4 inch tebal : 3,2 mm
pasak
pasak
700 cm
900 cm
30 cm
OD= 4 inch tebal : 3,2 mm
OD= 2,5 inch tebal : 2,9 mm
30 cm
200 cm
30 cm
OD= 2,5 inch tebal : 2,9 mm
30 cm
700 cm
137 cm
137 cm
200 cm
TIANG 7 M
25
lakop pelapisan oleh pipa 4,5 mm
160 cm
25
120 cm
25
25
426 cm
OD= 5 inch tebal : 4,5 mm
500 cm
OD= 5 inch tebal : 4,5 mm
POLE SPECIFICATION PAGE 15
TIANG 7 M
TIANG 9 M OD= 2,5 inch
OD= 2,5 inch
OD= 4 inch
OD= 5 inch
900 cm
700 cm
OD= 4 inch
OD= 5 inch
10 cm
25 cm
COR
MUKA TANAH
25 cm
COR
160 cm
25 cm
120 cm
25 cm
10 cm
POLE INSTALLATION PAGE 16
40 - 45 meter .
96 Core F.O.
40 - 45. meter
48 Core F.O.
48 Core F.O.
300
40 - 45 meter .
40 - 45. meter
Fixed Clamp
850
85
85
85
85
96 Core F.O.
Slack Support
Slack Support
Slack Kabel 15 m Kiri-Kanan
Slack Cabel 15 m Kiri-Kanan
85
85
85
85
Slack Cabel 15 m Kiri-Kanan
Slack Support ODC/ODP
CLOSURE 96c
CLOSURE 296c
264 Core F.O.
411 120
411
411 120
411
Stainless Steel Belt Buckle
Stainless Steel Belt Buckle
Handhole 40x40x40 cm
25
25 25
25 25
25
25 25
Berfungsi sebagai bak kontrol peralihan jalur
120
Bellmouth
120
Pipa Galvanis 2 x 1,25 inch
PERALIHAN JALUR KABEL TANAM KE KABEL UDARA SCALE :
POLE INSTALLATION DISTANCE PAGE 17
CYBER LN.10
CIRANJANG
B
PLAZA INDONESIA
MNC
CYBER LN.3
ARIOBIMO
A
CYBER
HH.01
HH.06 SJ.96/02
SJ.96/01
B
SJ.96/03
A
INDOVISION 2 INDOVISION 1
MCR RCTI GD. KOPERASI
B
B
A
SJ.96/07
SJ.96/06
SJ.96/05
SJ.96/04
A
ONE LINE DIAGRAM CABLE PAGE 18
PLAZA INDONESIA
MNC
ARIOBIMO
CYBER
CIRANJANG KFD 24" - 2.823 m
KFD 96" - 3.708m KFD 96" - 3.044m
KFD 96" - 3.264m
HH. 75 KFD 96" - 2.456m
HH. 06
HH. 33
HH. 27
HH. 11 HH. 01
KFD 96" - 3.319m
KFD 96" - 3.016m
JOINT ALL CORE
HH. 18
HH. 22
JOINT ALL CORE
JOINT ALL CORE
KFD 96" - 1.574m
KFD 96" - 3.296m
INDOVISION 2
INDOVISION 1
RCTI GD. KOPERASI
KFD 24" - 637m
KFD 96" - 3.259m KFD 96" - 3.939m
KFD 96" - 3.191m
KFD 96" - 3.174m
HH. 68
HH. 62 JOINT ALL CORE
KFD 96" - 3.307m
HH. 56 JOINT ALL CORE
HH. 35 HH. 50
HH. 44
JOINT ALL CORE
SYNOPTIC CABLE PAGE 19
Kabel yang digunakan dalam setiap tarikan adalah kabel 264 (22 tube @12 core)
Dari OLT keluarannya 2 kabel (2xFO264), rincian penggunaan masing-masing kabel : 8 Tube sebagai Backbone (Menghubungkan OLT dengan BRAS, harus kembali dari BRAS menuju BRAS lagi / membentuk ring) 14 Tube sebagai Feeder (supply ke ODC-ODC di tiap RW, idealya untuk RW yang berhomepass <512 dapat dicover oleh 1 ODC. Input untuk 1 ODC = 1 Tube kabel Feeder) 1 Tube untuk input tiap ODC 72 core hanya dipakai 8 core, jadi masih sisa 4 core yang dapat dimanfaaatkan untuk input FTTB 1 tarikan kabel dari 1 BRAS kembali ke BRAS lagi dapat mengcover minimal/ efektif 8 OLT, maksimal 16 OLT (dengan syarat HP tidak melebihi HP maksimal kapasitas OLT). Kapasitas OLT dihitung sbb : 1 ODP = 8 HP 1 ODC = 64 ODP x 8 HP = 512 HP 1 OLT = 2 x 14 ODC x 512 HP = 14336 HP 1 BRAS =2 x 8 OLT x 14336 HP = 229376 HP
Penembatan OLT sebaiknya berada di tengah-tengah dari beberapa target perumahan-perumahan yang akan dicover. Idealnya dari tiap tarikan menyupply 14 ODC, jadi total supply = 28 ODC.
CORE MANAGEMENT FOR BACKBONE & FEEDER PAGE 20
PAGE 21
PAGE 22
PELABELAN PADA ODC BAIK TIPE TIANG MAUPUN TIPE PEDESTAL DILAKUKAN BERDASARKAN NO. ODC HASIL AS BUILT DRAWING.
ODC24.SAG17.01A
LABEL ODC DITULISKAN PADA BAGIAN TENGAH PERMUKAAN DAN DI ATASNYA DIBERI LOGO PLAYMEDIA. PELABELAN DILAKUKAN DENGAN CAT SEMPROT ATAU MENGGUNAKAN SPON SEMENTARA LOGO DAPAT BERUPA STIKER
ODC72.SAG17.01
UKURAN : TINGGI : 5 cm - tipe 72 2,5 cm - tipe 24 TIPE HURUF : ARIAL BLACK WARNA : HITAM
PAGE 23
PELABELAN PADA ODP BAIK TIPE TIANG MAUPUN TIPE PEDESTAL DILAKUKAN BERDASARKAN NO. ODP HASIL AS BUILT DRAWING. LABEL ODP DITULISKAN PADA BAGIAN TENGAH PERMUKAAN DAN DI ATASNYA DIBERI LOGO PLAYMEDIA. SAG17.01.01.01
SAG17.01.01.01
PELABELAN DILAKUKAN DENGAN CAT SEMPROT ATAU MENGGUNAKAN SPON SEMENTARA LOGO DAPAT BERUPA STIKER UKURAN : TINGGI : 2,5 cm TIPE HURUF : ARIAL BLACK WARNA : HITAM
PAGE 24
FDT TYPE : GXF147-FDT2115D-72
PIGTAIL CORE INPUT TO ODP FEEDER
1 2 3
SPLITTER RACK 1 1 2
KASET FEEDER
3 4
KASET SAMBUNGAN CORE INPUT
2
5 6
3
7 4 8 9 5 10
KASET SAMBUNGAN CORE OUTPUT
11 6 12
KASET DISTRIBUSI
13
7
14
PIGTAIL KABEL OUTPUT TO ODP DISTRIBUSI
15
8
16 17
9
18 D
C
B
A
SPLITTER 1:8 x 5 KABEL DISTRIBUSI KABEL DISTRIBUSI
KABEL FEEDER
KABEL FEEDER
ODC 72 LAYOUT DIAGRAM 01
ODC 72 LAYOUT DIAGRAM 02
SCALE : N.T.S
SCALE : N.T.S
INSIDE ODC LABELING PAGE 25
ODP TYPE : ZTE - ZXA 10 ODN
SPLITER 1 PORT 1
XXX00.00.00.00
SPLITER 1 PORT 5
XXX00.00.00.00
SPLITER 1 PORT 2
XXX00.00.00.00
SPLITER 1 PORT 6
XXX00.00.00.00
SPLITER 1 PORT 3
XXX00.00.00.00
SPLITER 1 PORT 7
XXX00.00.00.00 XXX00.00.00.00 XXX00.00.00.00 XXX00.00.00.00
SPLITER ODC 1 PORT 1-8 SPLITER ODC 2 PORT 1-8 SPLITER ODC 3 PORT 1-8
SPLITER 1 PORT 4 SPLITER 1 PORT 8 SPLITER 2 PORT 1 SPLITER 2 PORT 5
XXX00.00.00.00 SPLITER 2 PORT 2
XXX00.00.00.00 XXX00.00.00.00
SPLITER 2 PORT 3 SPLITER 2 PORT 7
XXX00.00.00.00
SPLITER 2 PORT 4
XXX00.00.00.00
SPLITER 2 PORT 8
XXX00.00.00.00
SPLITER 3 PORT 1
XXX00.00.00.00
SPLITER 3 PORT 5
XXX00.00.00.00
SPLITER 3 PORT 2
XXX00.00.00.00 XXX00.00.00.00
SPLITER ODC 1
SPLITER 2 PORT 6
XXX00.00.00.00
TX . C X TX . C X TX . C X
SPLITER ODC 2
SPLITER 3 PORT 6
SPLITER 3 PORT 1-8 SPLITER 3 PORT 3
SPLITER 2 PORT 1-8 XXX00.00.00.00
SPLITER 3 PORT 7
XXX00.00.00.00
SPLITER 3 PORT 4
XXX00.00.00.00
SPLITER 3 PORT 8
SPLITER 1 PORT 1-8
XXX00.00.00.00
SPLITER ODC 3
KONEKTOR ATAS
KABEL FEEDER
Masukan maksimum 3 core
KABEL DISTRIBUSI
Keluaran maksimum 24 core
KABEL FEEDER
Masukan maksimum 3 core
KABEL DISTRIBUSI
Keluaran maksimum 24 core
ODC 24 mini memiliki : 1 lubang masukan kabel 1 lubang keluaran kabel
Kapasitas maksimum pelanggan terlayani sesuai port splitter cascade 2 adalah - satuan port: 24 x 8 = 192 port pelanggan - subscriber .
Total Penggunaan Core maksimum pada ODC 24 adalah sbb. : Masukan maksimum 3 core Keluaran maksimum 24 core Total penggunaan maksimum = 27 core
ODC 24 dapat digunakan secara serial : disesuaikan jumlah core pada kabel distribusi yang digunakan.
Kapasitas maksimum splitter digunakan : 3 spliter pada modul sebagai splitter cascade 1 24 splitter pada outside plant sebagai splitter casacade 2
INSIDE ODC24 INSTALLATION PAGE 26
ODC24 = modifikasi ODP TYPE : ZTE - ZXA 10 ODN
keluaran
masukan DETIL 2
SPLITER 1 PORT 1
XXX00.00.00.00
SPLITER 1 PORT 5
XXX00.00.00.00
SPLITER 1 PORT 2
XXX00.00.00.00
SPLITER 1 PORT 6
XXX00.00.00.00
SPLITER 1 PORT 3
XXX00.00.00.00
SPLITER 1 PORT 7
XXX00.00.00.00 XXX00.00.00.00 XXX00.00.00.00 XXX00.00.00.00
SPLITER ODC 1 PORT 1-8 SPLITER ODC 2 PORT 1-8 SPLITER ODC 3 PORT 1-8
keluaran
masukan
SPLITER 1 PORT 4 SPLITER 1 PORT 8 SPLITER 2 PORT 1 SPLITER 2 PORT 5
XXX00.00.00.00 SPLITER 2 PORT 2
XXX00.00.00.00
SPLITER 2 PORT 6
XXX00.00.00.00
SPLITER 2 PORT 3
XXX00.00.00.00
SPLITER 2 PORT 7
XXX00.00.00.00
SPLITER 2 PORT 4
XXX00.00.00.00
SPLITER 2 PORT 8
XXX00.00.00.00
SPLITER 3 PORT 1
XXX00.00.00.00
SPLITER 3 PORT 5
XXX00.00.00.00
SPLITER 3 PORT 2
XXX00.00.00.00
SPLITER 3 PORT 6
XXX00.00.00.00
SPLITER 3 PORT 3
XXX00.00.00.00
SPLITER 3 PORT 7
XXX00.00.00.00
SPLITER 3 PORT 4
XXX00.00.00.00
SPLITER 3 PORT 8
SPLITER ODC 1
masukan TX . C X TX . C X TX . C X
SPLITER ODC 2
SPLITER 3 PORT 1-8 SPLITER 2 PORT 1-8 SPLITER 1 PORT 1-8
keluaran DETIL 1
XXX00.00.00.00
DETIL 3 SPLITER ODC 3
KONEKTOR ATAS
KABEL FEEDER
KABEL DISTRIBUSI
KABEL FEEDER
RAK SISI LUAR
RAK SISI DALAM
SKALA : N.T.S
SKALA : N.T.S
KABEL DISTRIBUSI
Pelabelan dilakukan pada tiap posisi berlabel pada gambar. Tiap posisi berlabel diterangkan secara detil pada gambar Detil 1, Detil 2 dan Detil 3 pada halaman berikutnya. Pelabelan dilakukan dengan Cable Ties tipe khusus pelabelan ODC24 LABELLING PAGE 27
STANDARD WARNA TUBE VISUAL
WARNA
= BIRU
NO. TUBE
KAP. KABEL
=
TUBE 1
6 CORE
= ORANGE =
TUBE 2
12 CORE
= HIJAU
=
TUBE 3
= COKLAT =
TUBE 4
= ABU
=
TUBE 5
= PUTIH
=
TUBE 6
= MERAH
=
TUBE 7
= HITAM
=
TUBE 8
= KUNING =
TUBE 9
24/48 CORE
96 CORE
=
TUBE 10
= PINK
=
TUBE 11
= CYAN
=
TUBE 12
= PERAK
=
TUBE 14
= EMAS
=
TUBE 15
= BIRU
= UNGU
=
TUBE 16
= ORANGE =
TUBE 17
=
TUBE 18
= COKLAT =
TUBE 19
= ABU
=
TUBE 20
= PUTIH
=
TUBE 21
= MERAH
=
TUBE 22
= HIJAU
144 CORE
264 CORE
STANDARD WARNA CORE VISUAL
NO. CORE
WARNA =
BIRU
=
CORE 1
=
ORANGE
=
CORE 2
=
HIJAU
=
CORE 3
=
COKLAT
=
CORE 4
=
ABU
=
CORE 5
=
PUTIH
=
CORE 6
=
MERAH
=
CORE 7
=
HITAM
=
CORE 8
=
KUNING
=
CORE 9
=
UNGU
=
CORE 10
=
PINK
=
CORE 11
=
CYAN
=
CORE 12
KETERANGAN:
TUBE KABEL CORE KABEL JAKET KABEL
ODP/FAT ALOKASI CORE IN SPLITER JUMLAH HOMEPASS YANG DILAYANI JUMLAH DAN SPLITER YANG DIPASANG
ODP NAMA ODP/FAT
ALOKASI CORE:
FOxx-Tx-Cx
KAPASITAS CORE KABEL NO. TUBE KABEL NO. CORE KABEL
KAPASITAS KABEL, TUBE DAN CORE A. 6 CORE / 1 TUBE, 1 TUBE = 6 CORE B. 12 CORE / 2 TUBE, 1 TUBE = 6 CORE C. 24 CORE / 4 TUBE, 1 TUBE = 6 CORE D. 48 CORE / 4 TUBE, 1 TUBE = 12 CORE F. 96 CORE / 8 TUBE, 1 TUBE = 12 CORE G. 144 CORE / 12 TUBE, 1 TUBE = 12 CORE H. 264 CORE / 22 TUBE, 1 TUBE = 12 CORE
I
AS PLAN DRAWING RETAIL DISTRIBUTION FIBER TO THE HOME
G N
W A A E R R D _ _A L A T C U I O H Y C A E L T
AS PLAN NUMBER DATE
: :
Logo Of VENDOR or CONTRACTOR
LEGEND
G
IN A W E A R R A D _ L T_ A G IC U IN H O C Y W A A E E R T A R D _ L A L _ A T C U I O H Y C A E L T
QUANTITY
HUB OLT FIXING SLACK JOIN CLOSURE
ODC ODP
ODC/FDT/FIBER DISTRIBUSTION TERMINAL ODP/FAT/FIBER ACCESS TERMINAL
ODC ODP
ODC DISALLOWED ODP DISALLOWED
HANDHOLE EXISTING HANDHOLE 80X8080 CM HANDHOLE PIT 60X60X60 CM HANDHOLE PIT 40X40X40 CM CR
CABLE RISER
BA
RILLING ASPHALT (BORING ASPAL)
GA
EXCAVATION ASPHALT (GALI ASPAL)
GT
EXCAVATION LAND (GALI TANAH)
GR
EXCAVATION GRASS (GALI RUMPUT) POLE 9 METER POLE 7 METER GALVANIZED PIPE 6 METER POLE 9 DISALLOWED POLE 7 DISALLOWED DROP WIRE FIBER 6/2T FIBER 12/2T FIBER 24/4T FIBER 48/4T FIBER 72/6T FIBER 96/8T FIBER 144/12T FIBER 264/22T HOMEPASS
HUB AREA
:
NODE AREA
:
CITY AREA
:
PROVINCE AREA :
ASCERTAIN : PT. MNC KABEL MEDIAKOM
PT. MNC KABEL MEDIAKOM
OSP DIVISION HEAD
OSP DIVISION
CONSENT : PT. MNC KABEL MEDIAKOM
PT. MNC KABEL MEDIAKOM
OSP PLAN DEPT. PIC REGION
OSP PLAN DEPT. MANAGER
DRAWING NAME
SCALE
PAGE
NTS
OF SHEET
PT. MNC KABEL MEDIAKOM NAME
REVISION
DATE
SIGNATURE / CP
APPROVED BY CHECKED BY
DRAWN BY CONTACT PERSON
PAGE 28