March 2009 Water Analysis

  • Uploaded by: Ryan Howrish
  • 0
  • 0
  • May 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View March 2009 Water Analysis as PDF for free.

More details

  • Words: 659
  • Pages: 2
Page 1 of 2

Analytical Report Bill To: Culligan Water Conditioning Report To: Culligan Water Conditioning

Attn:

Project: ID:

Lot ID: Control Number:

12821 - 100 Street

Name:

Grande Prairie, AB, Canada T8V 4H3

Location: LSD:

Terry Boyd

P.O.:

Sampled By:

Pure Spirit Water Services

Date Received:

672336 A050554 Mar 11, 2009

Date Reported: Mar 17, 2009 Report Number: 1198233

Acct code:

Company:

Reference Number Sample Date Sample Time Sample Location Sample Description Sample Matrix Analyte

672336-1 March 11, 2009 NA Deionized Water Water

Units

Result

Nominal Detection Limit

Guideline Limit

Guideline Comments

Colour units NTU

<5 <0.1

5 0.1

15 5

Acceptable Acceptable

6.5 - 8.5

Low

°C

20.1

Physical and Aggregate Properties Colour Turbidity

Apparent, Potable

Routine Water pH Temperature of observed pH Electrical Conductivity Calcium Magnesium Sodium Potassium Iron Manganese Chloride Fluoride Nitrate - N Nitrite - N Nitrate and Nitrite - N Sulfate (SO4) Hydroxide Carbonate Bicarbonate P-Alkalinity T-Alkalinity Total Dissolved Solids Hardness Ionic Balance

5.91

Extractable Extractable Extractable Extractable Extractable Extractable Dissolved

as CaCO3 as CaCO3 as CaCO3

µS/cm at 25 C mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L %

n/a

2 <0.2 <0.2 <0.4 <0.4 <0.01 <0.005 0.5 <0.05 <0.01 <0.005 <0.01 <0.9 <5 <6 <5 <5 <5 <1 <1 <1

1 0.2 0.2 0.4 0.4 0.01 0.005 0.4 0.05 0.01 0.005 0.01 0.9 5 6 5 5 5 1

200 0.3 0.05 250 1.5 10 1 10 500

500

Approved by: Laurie Brown, MSc Client Services Manager Bodycote Testing Group www.bodycote.com www.bodycotetesting.com 7217 Roper Road NW · Edmonton · AB · T6B 3J4 · Canada · Tel: +1 (780) 438-5522 · Fax: +1 (780) 438-0396 Terms and Conditions: www.bodycotetesting.com/terms&conditions

n/a n/a n/a Acceptable n/a Acceptable Acceptable Acceptable Pass Pass Pass Pass Acceptable n/a n/a n/a n/a n/a Acceptable Soft n/a

Page 2 of 2

Methodology and Notes Bill To: Culligan Water Conditioning Report To: Culligan Water Conditioning

Attn:

Project: ID:

12821 - 100 Street

Name:

Grande Prairie, AB, Canada T8V 4H3

Location: LSD:

Terry Boyd

P.O.:

Sampled By:

Lot ID: Control Number: Pure Spirit Water Services

Date Received:

672336 A050554 Mar 11, 2009

Date Reported: Mar 17, 2009 Report Number: 1198233

Acct code:

Company:

Method of Analysis Method Name

Reference

Alkalinity, pH, and EC in water

APHA

Alkalinity, pH, and EC in water

APHA

Alkalinity, pH, and EC in water

Method

Date Analysis Started

Location

* Conductivity, 2510

13-Mar-09

BTG Edmonton

* Electrometric Method, 4500-H+ B

13-Mar-09

BTG Edmonton

APHA

* Titration Method, 2320 B

13-Mar-09

BTG Edmonton

Anions (Routine) by Ion Chromatography

APHA

* Ion Chromatography with Chemical Suppression of Eluent Cond., 4110 B

12-Mar-09

BTG Edmonton

Approval-Edmonton

APHA

Checking Correctness of Analyses, 1030 E

12-Mar-09

BTG Edmonton

Chloride in Water

APHA

* Automated Ferricyanide Method, 4500- 13-Mar-09 Cl- E

BTG Edmonton

Colour (Apparent) in water

APHA

* Visual Comparison Method, 2120 B

16-Mar-09

BTG Edmonton

Metals Trace (Extractable) in water

APHA

Hardness by Calculation, 2340 B

12-Mar-09

BTG Edmonton

Metals Trace (Extractable) in water

APHA

* Inductively Coupled Plasma (ICP) Method, 3120 B

12-Mar-09

BTG Edmonton

Turbidity in Water

APHA

* Nephelometric Method, 2130 B

16-Mar-09

BTG Edmonton

* Bodycote method(s) based on reference method

References Guideline APHA

Guidelines for Canadian Drinking Water Quality, 6th Edition, May 16, 2006 Standard Methods for the Examination of Water and Wastewater

Comments: • Sample 672336-1; 2989445 The ion balance was outside the range 90 - 110% for sample 672336-1. The ion balance can be variable in samples with TDS less than 100 mg/L.

Please direct any inquiries regarding this report to our Client Services group. Results relate only to samples as submitted. The test report shall not be reproduced except in full, without the written approval of the laboratory. Bodycote Testing Group www.bodycote.com www.bodycotetesting.com 7217 Roper Road NW · Edmonton · AB · T6B 3J4 · Canada · Tel: +1 (780) 438-5522 · Fax: +1 (780) 438-0396 Terms and Conditions: www.bodycotetesting.com/terms&conditions

Related Documents