Dec 2008 Water Analysis

  • Uploaded by: Ryan Howrish
  • 0
  • 0
  • May 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Dec 2008 Water Analysis as PDF for free.

More details

  • Words: 653
  • Pages: 2
Page 1 of 2

Analytical Report Bill To: Pure Spirit Water Services Report To: Pure Spirit Water Services Spirit River, AB, Canada T0H 3G0 Attn: Vern Howrish Sampled By: Company:

Project: ID: Name: Location: LSD: P.O.: Acct code:

Reference Number Sample Date Sample Time Sample Location Sample Description Sample Matrix Analyte Physical and Aggregate Properties Colour Apparent, Potable Turbidity Routine Water pH Temperature of observed pH Electrical Conductivity Calcium Extractable Magnesium Extractable Sodium Extractable Potassium Extractable Iron Extractable Manganese Extractable Chloride Dissolved Fluoride Nitrate - N Nitrite - N Nitrate and Nitrite - N Sulfate (SO4) Hydroxide Carbonate Bicarbonate P-Alkalinity as CaCO3 T-Alkalinity as CaCO3 Total Dissolved Solids Hardness as CaCO3 Ionic Balance

Units

Lot ID: Control Number: Date Received: Date Reported: Report Number:

DE-I Plant

660579 A 050162 Dec 16, 2008 Dec 18, 2008 1183490

660579-1 December 16, 2008 NA Deionized Water Water Nominal Detection Limit Result

Colour units NTU

6 0.1

5 0.1

°C

6.32 19.8

µS/cm at 25 C mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L mg/L %

4 <0.2 <0.2 0.6 <0.4 <0.03 <0.005 <0.4 <0.05 <0.01 <0.005 <0.01 <0.9 <5 <6 <5 <5 <5 <1 <1 >4

1 0.2 0.2 0.4 0.4 0.03 0.005 0.4 0.05 0.01 0.005 0.01 0.9 5 6 5 5 5 1

Guideline Limit

Guideline Comments

15 5

Acceptable Acceptable

6.5 - 8.5

Low n/a

200 0.3 0.05 250 1.5 10 1 10 500

500

Approved by: Darren Crichton, BSc, PChem Operations Chemist Bodycote Testing Group www.bodycote.com www.bodycotetesting.com 7217 Roper Road NW · Edmonton · AB · T6B 3J4 · Canada · Tel: +1 (780) 438-5522 · Fax: +1 (780) 438-0396 Terms and Conditions: www.bodycotetesting.com/terms&conditions

n/a n/a n/a Acceptable n/a Acceptable Acceptable Acceptable Pass Pass Pass Pass Acceptable n/a n/a n/a n/a n/a Acceptable Soft n/a

Page 2 of 2

Methodology and Notes Bill To: Pure Spirit Water Services Report To: Pure Spirit Water Services Spirit River, AB, Canada T0H 3G0 Attn: Vern Howrish Sampled By: Company:

Project: ID: Name: Location: LSD: P.O.: Acct code:

DE-I Plant

Lot ID: Control Number: Date Received: Date Reported: Report Number:

660579 A 050162 Dec 16, 2008 Dec 18, 2008 1183490

Method of Analysis Method Name

Reference

Alkalinity, pH, and EC in water

APHA

Alkalinity, pH, and EC in water Alkalinity, pH, and EC in water

Method

Date Analysis Started

Location

* Conductivity, 2510

17-Dec-08

BTG Edmonton

APHA

* Electrometric Method, 4500-H+ B

17-Dec-08

BTG Edmonton

APHA

* Titration Method, 2320 B

17-Dec-08

BTG Edmonton

Anions (Routine) by Ion Chromatography

APHA

* Ion Chromatography with Chemical Suppression of Eluent Cond., 4110 B

17-Dec-08

BTG Edmonton

Approval-Edmonton

APHA

Checking Correctness of Analyses, 1030 E

17-Dec-08

BTG Edmonton

Chloride in Water

APHA

* Automated Ferricyanide Method, 4500- 18-Dec-08 Cl- E

BTG Edmonton

Colour (Apparent) in water

APHA

* Visual Comparison Method, 2120 B

18-Dec-08

BTG Edmonton

Metals Trace (Extractable) in water

APHA

Hardness by Calculation, 2340 B

17-Dec-08

BTG Edmonton

Metals Trace (Extractable) in water

APHA

* Inductively Coupled Plasma (ICP) Method, 3120 B

17-Dec-08

BTG Edmonton

Turbidity in Water

APHA

* Nephelometric Method, 2130 B

18-Dec-08

BTG Edmonton

* Bodycote method(s) based on reference method

References APHA Guideline

Standard Methods for the Examination of Water and Wastewater Guidelines for Canadian Drinking Water Quality, 6th Edition, May 16, 2006

Comments: • Sample 660579-1; 2934985 The ion balance was outside the range 90 - 110% for sample 660579-1. The ion balance can be variable in samples with TDS less than 100 mg/L.

Please direct any inquiries regarding this report to our Client Services group. Results relate only to samples as submitted. The test report shall not be reproduced except in full, without the written approval of the laboratory. Bodycote Testing Group www.bodycote.com www.bodycotetesting.com 7217 Roper Road NW · Edmonton · AB · T6B 3J4 · Canada · Tel: +1 (780) 438-5522 · Fax: +1 (780) 438-0396 Terms and Conditions: www.bodycotetesting.com/terms&conditions