RULES CHANGE NOTICE No.1

October 2018

Part 1 Seagoing Ships

Volume I

RULES FOR CLASSIFICATION AND SURVEYS

2018 Biro Klasifikasi Indonesia

Copyright © 2017 Biro Klasifikasi Indonesia Jl. Yos Sudarso No. 38-40, Tanjung Priok Jakarta 14320 - Indonesia

[email protected] www.bki.co.id

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

Rules Changes Notice No. 1 – October 2018 Table 1 – Amendments Incorporates in This Notice These amendments are affective from 1 January 2019 Paragraph

Title/Subject

Section 3 – Surveys – General Requirements A General Information 1.9 Surveys for Maintenance Class

8.

Remote Inspection Techniques (RIT)

B 1.7.3

Surveys for Maintenance Class Performance of survey

Status/Remark

To add new provision for commercial ships owned or chartered rby governments, which are utilized in support of military operations or service. To add new requirement for remote inspection techniques (RIT).

To add new requirements for performance of InWater Survey. C Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels A-B 2.4 Pressure Relief Valves To change terms of “a random selection of pressure” is replaced with terms “pressure” Section 4 – Surveys I Additional Requirements for Ships with ESP Notation A. General 5. Access to Structures 5.5 No title To add new provision for The use of hydraulic arm vehicles or aerial lifts (“Cherry picker”) B. Oil Tankers 2. Annual Surveys I 2.1.2 No title To add new items that should be considered for annual surveys. C. Double Hull Oil Tankers 2. Annual Surveys I 2.1.2 No title To add new items that should be considered for annual surveys. 4. Class Renewal Surveys Table 4-I.4 Class Renewal Surveys of Double Hull Oil Tankers, Ore/Oil Ships etc. To change the meaning of Minimum Requirements for Close-Up Surveys ballast tank in note 1. D. Chemical Tankers 2. Annual Surveys I 2.1.2 No title To add new items that

B iro Klasifi kasi Indonesia – 2018

Page 1

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

Paragraph

Title/Subject

Status/Remark should be considered for annual surveys.

E. 2. 2.1.2

Bulk Carriers Annual Surveys I No title

2.3.4

Repairing of cargo hatch securing system

F. 2. 2.1.2

Double Skin Bulk Carriers Annual Surveys I No title

2.3.4

Repairing of cargo hatch securing system

Annex 5 A.5

Annexes to Section 1-3 Definition Remote Inspection Techniques (RIT)

B iro Klasifi kasi Indonesia – 2018

To add new items that should be considered for annual surveys. To change references for the strength of securing devices.

To add new items that should be considered for annual surveys. To change references for the strength of securing devices.

To add new definition for Remote Inspection Techniques (RIT)

Page 2

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

Section 3

Surveys – General Requirements

A.

General Information

1.

Surveys for Maintenance Class

1.9 Special consideration may be given in application of relevant sections of this Rules for commercial ships owned or chartered by governments, which are utilized in support of military operations or service s. (IACS UR Z3, Z7, Z18, Z21) 8.

Remote Inspection Techniques (RIT)

8.1 Remote Inspection Techniques (RIT) are permitted as an alternative to close-up survey. The RIT shall provide the information normally obtained from a close-up survey. RIT surveys shall be carried out in accordance with the requirements given here-in and the requirements of IACS Recommendation 42 Guidelines for Use of Remote Inspection Techniques for surveys. These considerations shall be included in the proposals for use of a RIT which shall be submitted in advance of the survey so that satisfactory arrangements can be agreed with BKI. 8.2 Consideration may be given by the attending Surveyor to allow use of Remote Inspection Techniques (RIT) as an alternative to close-up survey. Surveys conducted using a RIT are to be completed to the satisfaction of the attending Surveyor. 8.3 The equipment and procedure for observing and reporting the survey using a RIT shall be discussed and agreed with the parties involved prior to the RIT survey, and suitable time shall be allowed to set-up, calibrate and test all equipment beforehand. 8.4 When using a RIT as an alternative to close-up survey, if not carried out by BKI itself, it shall be conducted by a firm approved as a service supplier according to Rules for Approval Manufacturers and Service Suppliers (Pt.1, Vol. XI) and shall be witnessed by an attending surveyor of BKI. 8.5 The structure to be examined using a RIT shall be sufficiently clean to permit meaningful examination. Visibility shall be sufficient to allow for a meaningful examination. The classification society shall be satisfied with the methods of orientation on the structure. 8.6 The surveyor shall be satisfied with the method of data presentation including pictorial representation, and a good two-way communication between the surveyor and RIT operator shall be provided. 8.7 If the RIT reveals damage or deterioration that requires attention, the surveyor may require traditional survey to be undertaken without the use of a RIT. 8.8 For surveys conducted by use of a remote inspection technique, one or more of the following means for access, acceptable to the surveyor, shall be provided: –

unmanned robot arm



remotely operated vehicles (ROV)



unmanned aerial vehicles /drones



other means acceptable to BKI.

B iro Klasifi kasi Indonesia – 2018

Page 3

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

B.

Surveys for Maintenance of Class A-B

1.7

In-Water Surveys

1.7.3

Performance of survey

1)

The diving firm assisting in in water surveys shall be approved by BKI for this purpose in accordance with Rules for Approval Manufacturers and Service Suppliers (Pt.1, Vol. XI).

2)

Validity of an approval granted will depend on the continued qualification for satisfactorily carrying out the work required. The approval will have to be renewed after a period not exceeding 3 years.

3)

Unless accessible from outside with the aid of the vessel's trim and/or heel, underwater parts are to be surveyed and/or relevant maintenance work is to be carried out with assistance by a diver whose performance is controlled by the Surveyor, using an underwater camera with monitor, two– way communication and recording systems.

4)

The In-water Survey is to be carried out with the ship in sheltered water and preferably with weak tidal streams and currents. The in-water visibility and the cleanliness of the hull below the waterline is to be clear enough to permit a meaningful examination which allows the surveyor and diver to determine the condition of the plating, appendages and the welding. BKI is to be satisfied with the methods of orientation of the divers or Remotely Operated Vehicle (ROV) on the plating, which should make use where necessary of permanent markings on the plating at selected points.

5)

The equipment, procedure for observing and reporting the survey are to be discussed with the parties involved prior to the In -water Survey, and s uitable time is to be allowed to per mit the in -water survey f irm to test all equipment beforehand.

6)

The underwater pictures on the surface monitor screen shall offer reliable technical information such as to enable the Surveyor to judge the parts and/ or the areas surveyed.

7)

Documentation suited for video reproduction including voice is to be made available to BKI.

C.

Periodic Survey of Fuel Installations on Ships other than Liquefied Gas Carriers utilizing gas or other low flash point fuels A-B

2.

Class Renewal Survey

2.4

Pressure Relief Valves

i.

Fuel Storage Tank Pressure Relief Valves. The pressure relief valves for the fuel storage tanks are to be opened for examination, adjusted, and function tested. If the tanks are equipped with relief valves with non-metallic membranes in the main or pilot valves, such non-metallic membranes are to be replaced.

ii.

Fuel Supply and Bunkering Piping Pressure Relief Valves. A random selection of Pressure relief valves for the fuel supply and bunkering piping are to be opened for examination, adjusted, and function tested. Where a proper record of continuous overhaul and retesting of individually identifiable relief valves is maintained, consideration will be given to acceptance on the basis of opening, internal examination, and testing of a representative sampling of valves, including each size and type of liquefied gas or vapour relief valve in use, provided there is logbook evidence that the remaining valves have been overhauled and tested since crediting of the previous Class Renewal Survey.

B iro Klasifi kasi Indonesia – 2018

Page 4

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

iii.

Pressure/Vacuum Relief Valves. The pressure/vacuum relief valves, rupture disc and other pressure relief devices for inter-barrier spaces and hold spaces are to be opened, examined, tested and readjusted as necessary, depending on their design.

Section 4

Surveys

I.

Additional Requirements for Ships with ESP Notation

A.

General

5.

Access to Structures

5.5

Notwithstanding the above requirements:



The use of a portable ladder fitted with a mechanical device to secure the upper end of the ladder is acceptable for the "close-up examination of sufficient extent, minimum 25% of frames, to establish the condition of the lower region of the shell frames including approx. lower one third length of side frame at side shell and side frame end attachment and the adjacent shell plating of the forward cargo hold" at Annual Survey.



The use of hydraulic arm vehicles or aerial lifts ( “Cherry picker ”) may be accepted by the attending sur veyor for the close -up survey of the upper part of side shell frames or other structures in all cas es where the maximum working height is not more than 17 m.

B.

Oil Tankers

2.

Annual Surveys

2.1

General

2.1.2 The survey is to consist of an examination for the purpose of ensuring, as far as practicable, that the hull and piping are maintained in a satisfactory condition and should take into account the service history, condition and ex tent of the corrosion prevention system of ballast tanks and areas identif ied in the survey report f ile.

C.

Double Hull Oil Tankers

2.

Annual Surveys

2.1

General

2.1.2 The survey is to consist of an examination for the purpose of ensuring, as far as practicable, that the hull and piping are maintained in a satisfactory condition and should take into account the service history, condition and ex tent of the corrosion preve ntion system of ballast tanks and areas identif ied in the survey report f ile.

B iro Klasifi kasi Indonesia – 2018

Page 5

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

4.

Class Renewal Surveys

Table 4-I.4 Class Renewal Surveys of Double Hull Oil Tankers, Ore/Oil Ships etc. Minimum Requirements for Close-Up Surveys Class Renewal Survey No. I age ≤ 5

Class Renewal Survey No. II 5 < age ≤ 10

Class Renewal Survey No. III 10 < age ≤ 15

Class Renewal Survey No. IV and Subsequent age > 15

One web frame (1), in a ballast All web frames (1), in a ballast All web frames (1), in all bal- As for Class Renewal Survey tank (see Note 1) tank (see Note 1) last tanks for age from 10 to 15 years The knuckle area and the upper part (5 metres approximately) of Additional transverse areas one web frame in each remainas deemed necessary by BKI ing ballast tank (6) One deck transverse, in a cargo One deck transverse, in two All web frames (7), including oil tank (2) cargo oil tanks (2) deck transverse and cross ties, if fitted, in a cargo oil tank One web frame (7), including deck transverse and cross ties, if fitted, in each cargobulkheads, oil tank in One transverse bulkhead (4), in One transverse bulkhead (4), in remaining All transverse a ballast tank (see Note 1) each ballast tank (see Note 1) all cargo oil (3) and ballast (4) tanks One transverse bulkhead (5), in One transverse bulkhead (5), in a cargo oil centre tank two cargo oil centre tanks One transverse bulkhead (5), in One transverse bulkhead (5), in a cargo oil wing tank (see Note a cargo oil wing tank (see Note 2) (2), (3), (4), (5), (6) and (7) are 2) (1), areas to be subjected to close-up surveys and thickness measurements (see Fig. 4-I.2 and 4(1):

(2): (3): (4): (5): (6):

(7):

I.3). Web frame in a ballast tank means vertical web in side tank, hopper web in Hooper tank, floor in double bottom tank and deck transverse in double deck tank (where fitted), including adjacent structural members. In fore and aft peak tanks web frame means a complete transverse web frame ring including adjacent structural members Deck transverse, including adjacent deck structural members (or external structure on deck in way of the tank, where applicable) Transverse bulkhead complete in cargo tanks, including girder system, adjacent structural members (such as longitudinal bulkheads) and internal structure of lower and upper stools, where fitted Transverse bulkhead complete in ballast tanks, including girder system and adjacent structural members, such as longitudinal bulkheads, girders in double bottom tanks, inner bottom plating, hopper side, connecting brackets Transverse bulkhead lower part in cargo tank, including girder system, adjacent structural members (such as longitudinal bulkheads) and internal structure of lower stool, where fitted The knuckle area and the upper part (5 metres approximately), including adjacent structural members. Knuckle area is the area of the web frame around the connections of the slope hopper plating to the inner hull bulkhead and the inner bottom plating, up to 2 metres from the corners both on the bulkhead and the double bottom Web frame in a cargo oil tank means deck transverse, longitudinal bulkhead structural elements and cross ties, where fitted, including adjacent structural members

Note 1: Ballast tank: means double bottom tank plus double side tank plus double deck tank, as applicable, even if these tanks are separate Apart from the fore and aft peak tanks, the term "ballast tank" has the following meaning: .1 all ballast compartments (hopper tank, side tank and double-deck tank, if separate from double-bottom tank) located on one side, i.e. portside or starboard side, and additionally double-bottom tank on portside plus starboard side, when the longitudinal central girder is not watertight and, therefore, the double-bottom tank is a unique compartment from portside to starboard side; or .2 all ballast compartments (double-bottom tank, hopper tank, side tank and double-deck tank) located on one side, i.e. portside or starboard side, when the longitudinal central girder is watertight and, therefore, the portside double-bottom tank separate from the starboard-side double-bottom tank. Note 2: Where no centre cargo tanks are fitted (as in case of centre longitudinal bulkhead), transverse bulkheads in wing tanks are to be surveyed

B iro Klasifi kasi Indonesia – 2018

Page 6

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

D.

Chemical Tankers

2.

Annual Surveys

2.1

General

2.1.2 The survey is to consist of an examination for the purpose of ensuring, as far as practicable, that the hull and piping are maintained in a satisfactory condition and should take into account the service history, condition and ex tent of the corrosion prevention system of ballast tanks and areas identif ied in the survey report f ile.

E.

Bulk Carriers

2.

Annual Surveys

2.1

General

2.1.2 The survey is to consist of an examination for the purpose of ensuring, as far as practicable, that the hull and piping are maintained in a satisfactory condition and should take into account the service history, condition and ex tent of the corrosion preve ntion system of ballast tanks and areas identif ied in the survey report f ile. 2.3.4 Where the cargo hatch securing system does not function properly, repairs should be carried out under the supervision of the BKI’s surveyor. Where hatch covers or coamings undergo substantial repairs, the strength of securing devices should be upgraded to comply with Annex 13 of IMO-Resolution A.744(18) as amended Annex 11 of IMO Resolution MSC 261 (84) as amended or Rules for Hull (Pt.1, Vol. II), Sec. 17.B. 5.

F.

Double Skin Bulk Carriers

2.

Annual Surveys 2.1

General

2.1.2 The survey is to consist of an examination for the purpose of ensuring, as far as practicable, that the hull and piping are maintained in a satisfactory condition and should take into account the service history, condition and ex tent of the corrosion prevention system of ballast tanks and areas identif ied in the survey report f ile. 2.3.4 Where the cargo hatch securing system does not function properly, repairs should be carried out under the supervision of the BKI’s surveyor. Where hatch covers or coamings undergo substantial repairs, the strength of securing devices should be upgraded to comply with Annex 13 of IMO-Resolution A.744(18) as amended Annex 11 of IMO Resolution MSC 261 (84) as amended or Rules for Hull (Pt.1, Vol. II), Sec. 17.B. 5.

B iro Klasifi kasi Indonesia – 2018

Page 7

Pt Vol

1 I

Seagoing Ships Rules for Classification and Surveys

Rules Changes Notice No. 1

Annexes to Section 1-3 A.5

Definition

Remote Inspection Techniques (RIT) Remote Inspection Technique is a means of survey that enables examination of any part of the structure without the need for direct physical acces s of the surveyor (refer to Rec.42).

B iro Klasifi kasi Indonesia – 2018

Page 8

Related Documents


More Documents from "eunice demaclid"