ILUMINACIÓN

LAURA JULIET MANCIPE PIÑA ID 637654

Presentado a JORGE EDWIN FABER SANCHEZ MARROQUIN

UNIVERISIDAD MINUTO DE DIOS RIESGOS FÍSICOS NRC 134813 2019

MEDICIÓN DEL AREA DE CORDINACIÓN

MEDIAS

Constante - Formula L: 5,70 mts W: 4,48 mts Hm: 1,52 mts

𝐶𝑠 =

4,48 mts ∗ 4,48 mts 1,52 mts ( 4,48 mts + 4,48 mts )

20.07 𝑚𝑡𝑠 2 𝐶𝑠 = 1,52 mts ( 8,96 mts )

𝐶𝑠 =

20.07 𝑚𝑡𝑠 2 13,61 𝑚𝑡𝑠 2

𝐶𝑠 = 1,47 ~ 9

Número mínimo de puntos - Formula

𝑁𝑚𝑃 = 9 =

4,48 mts ∗ 5,70 mts 4,48 mts ∗ 4,48 mts

25,53 𝑚𝑡𝑠 2 𝑁𝑚𝑃 = 9 = 20,07 𝑚𝑡𝑠 2 𝑁𝑚𝑃 = ( 9 ∗ 1,27 ) 𝑁𝑚𝑃 = 11,43 ~ 12

W = 4,48 mts L = 4,48 mts L = 5,70 mts

Iluminación Promedio – Formula

Ventana

P2 Luminaria

P3

P6

P1

P4

P5

P8 Luminaria

P9

P12

P7

P10

P11 Ventana

Puerta

Promedio Puntos – Formula

𝑃1 = 113,2 lux – 113,4 lux – 113,1 lux = 113,23 lux

𝑃2 = 126,3 lux – 128,1 lux – 127,3 lux

𝑃4 = 89,7 lux - 88,5 lux - 86,9 lux = 88, 36 lux

𝑃5 = 200,2 lux – 182,4 lux – 184,9 lux

= 127,23 lux

=189,16 lux

𝑃3 = 59,5 lux – 54,2 lux – 55,9 lux

𝑃6 = 244,2 lux – 243,8 lux – 244,1 lux

= 56,53 lux

= 244,03 lux

𝑃7 = 240,2 lux – 239,0 lux – 239,8 lux

𝑃10 = 116,2 lux – 117,1 lux – 117,3 lux

= 239,66 lux

= 116,86 lux

𝑃8 = 319,0 lux – 319,0 lux – 318,6 lux

𝑃11 = 118,9 lux – 119.9 lux – 120,8 lux

= 318,86 lux

= 119,86 lux

𝑃9 = 98.8 lux – 98,9 lux – 98,6 lux

𝑃12 = 137,8 lux – 138,0 lux – 136,1 lux

= 98,76 lux

= 137, 3 lux

𝐸𝑝 =

1 (113,23 lux + 127,23 lux + 56,53 lux + 88, 36 lux + 189,16 lux + 244,03 lux 12 + 239,66 lux + 318,86 lux + 98,76 lux + 116,86 lux + 119,86 lux + 137, 3 lux )

𝐸𝑝 =

1 12

(1849,84 lux)

𝐸𝑝 = 0,08 (1849,84 lux) 𝐸𝑝 = 147, 98 lux

Factor de Uniformidad – Formula

𝐹𝑢1 =

113,23 𝑙𝑢𝑥 = 0, 76 147,98 𝑙𝑢𝑥

𝐹𝑢7 =

147,98𝑙𝑢𝑥 = 0, 61 239,66 𝑙𝑢𝑥

𝐹𝑢2 =

127,23 𝑙𝑢𝑥 = 0, 85 147,98 𝑙𝑢𝑥

𝐹𝑢8 =

147,98𝑙𝑢𝑥 = 0, 46 318,86 𝑙𝑢𝑥

𝐹𝑢3 =

56,53 𝑙𝑢𝑥 = 0, 38 147,98 𝑙𝑢𝑥

𝐹𝑢9 =

98,76𝑙𝑢𝑥 = 0, 66 147,98𝑙𝑙𝑢𝑥

𝐹𝑢4 =

88,36𝑙𝑢𝑥 = 0, 59 147,98 𝑙𝑢𝑥

𝐹𝑢10 =

116,86𝑙𝑢𝑥 = 0, 78 147,98𝑙𝑙𝑢𝑥

𝐹𝑢5 =

147,98𝑙𝑢𝑥 = 0, 78 189,16 𝑙𝑢𝑥

𝐹𝑢11 =

119,86𝑙𝑢𝑥 = 0, 80 147,98𝑙𝑙𝑢𝑥

𝐹𝑢6 =

147,98𝑙𝑢𝑥 = 0, 60 244,03𝑙𝑢𝑥

𝐹𝑢12 =

137,3 𝑙𝑢𝑥 = 0, 92 147,98𝑙𝑙𝑢𝑥

PUNTOS A INTERVEINR P3 = 0,38

P7 =0.61

P4 = 0,59

P8 = 0,46

P6 = 0,60