PHASED ARRAY ULTRASONIC TESTING NDT PROCEDURE

NDE Procedure for Ultrasonic Testing of Plate to Plate Butt Weld Using Phased Array Ultrasonic Testing Technique

Procedure Details Procedure Name

PAUT-01 R-00 ; Issue-1

Test Detail Product for PAUT Examination

Plate

Material

Carbon Steel

Weld Detail Plate thickness to be PAUT examined 12mm Technique

Phased Array Ultrasonic Test Manual Pulse echo Contact 0

Scanning Method

Scanning Encoder included

Total no of Pages along with cover page

Prepared By Name Level-III Signature

Page 1 of 32

Reviewed & Approved Customer /Client By Approved By

Contents No table of contents entries found.

1) SCOPE 1.1.Examination & Weld Detail 1.2.Table-1No table of figures entries found. 2) NORMATIVE REFERENCES 2.1. Table-2 No table of figures entries found. 3) NDT PERSONNEL 4) MATERIALS AND EQUIPMENT 4.1. Main NDT Equipment(PAUT Flaw Detector,Probe-wedges,Encoder & Batteries) 4.1.1. SIUI PAUT EQUIPMENT 4.1.2. PAUT 64 elementProbe 4.1.3. PAUT-Wedge 4.1.4. Encoder 4.1.5. Manual Scanner 4.1.6. Calibration Status 4.2. Calibration Status 4.3. Pre-Serviceability Checks 4.3.1. Active element check 4.3.2. Horizontal Display (Screen) -Height Linearity Check 4.3.3. Amplitude Control Linearity Check 4.3.4. Time Base Linearity Check 4.3.5. Data Display & Recording 4.4. ANCILLARY EQUIPMENT 4.4.1. PAUT Basic Calibration Block 4.4.2. IIW PAUT Reference Block 4.4.3. Couplant 4.4.4. Measuring Equipment (Tapes,500mm Ruler) 4.4.5. Magnetic Guides 4.4.6. Data Storeage Memory card 4.4.7. Viewing Aids (Tomoview Software)

5) TEST PIECE /SPECIMEN 5.1. Physical Condition and Surface Preparation 5.1.1. Surface Temperature 5.1.2. Scanning surface preparation 5.1.3. Scanning Access 5.1.4. Surface Roughness 5.1.5. Removal of Protective coatings 5.2. VOLUME /AREA to be Tested 5.2.1. Scan Plan Figue-1No table of figures entries found. 5.2.2. Scan Plan for Parent metal,HAZ 10mm either side & Weld metal. 5.2.3. Reference Datum 5.2.4. Discontinuities Sought 5.3. Performance of the Test 5.3.1. NDT Methods /Technique to be used. 5.3.2. Setting –up of the PAUT Apparatus 5.3.3. Active Element Check 5.3.4. Velocity Calibration 5.3.5. Wedge Delay Compensation 5.3.6. Sensitivity Delay Compensation 5.3.7. Time Corrected Gain (TCG) 5.4. Conducting the PAUT Test 5.4.1. PAUT NDT Written Instructions 5.5. Characterization of Discontinuities 6) ACCEPTANCE CRITERIA 7) POST TEST PROCEDURE 7.1. Disposition of Non-Conforming Product 7.1.1. Labelling 7.1.2. Segregation 7.2. RESTORATION OF PROTECTIVE COATINGS 8) TEST REPORT 9) Overall Presentation.

Related Documents

Paut Nots-krishnan.pdf
November 2019 12
Table
November 2019 80
Table
November 2019 78
Table
May 2020 28

More Documents from ""

Snt-tc-1a.pdf
October 2019 11
Api-653-nav-63052.pdf
October 2019 14
Cv-ndtl3 Tpi-nav.docx
October 2019 17
Isl-aut-hydroform.pdf
October 2019 15
Lt Sg Iii.pdf
October 2019 16