01. Profil Organisasi Up2d Rev 3.docx

  • Uploaded by: Septian Alif Farhansyah
  • 0
  • 0
  • June 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View 01. Profil Organisasi Up2d Rev 3.docx as PDF for free.

More details

  • Words: 2,798
  • Pages: 17
PROFIL PLN UP2D SULUTTENGGO

PLN UP2D SULUTTENGGO EXCELLENT

PROFIL PLN UP2D SULUTTENGGO

VISI DAN MISI VISI Diakui Sebagai Perusahaan Kelas Dunia Yang Bertumbuh Kembang, Unggul Dan Terpercaya Dengan Bertumpu Pada Potensi Insani MISI 1. 2. 3. 4.

Menjalankan Bisnis Kelistrikan Dan Bidang Yang Lain Yang Terkait Kepuasan Pelanggan, Anggota Perusahaan Dan Pemegang Saham Menjadikan Tenaga Listrik Sebagai Media Untuk Meningkatkan Kualitas Kehidupan Masyarakat Mengupayakan Agar Tenaga Listrik Menjadi Pendorong Kegiatan Ekonomi Menjalankan Kegiatan Usaha Yang Berwawasan Lingkungan

FUNGSI DAN TUGAS POKOK Mengelola kegiatan Operasi Sistem Distribusi, Gardu Induk, Scada dan Telekomunikasi didaerah kerjanya secara efisien guna menjamin mutu dan keandalan sistem pendistribusian tenaga listrik untuk mencapai kinerja Unit MOTTO PLN UP2D Suluttenggo Operational and Maintenance Excellent GAMBARAN UMUM PLN UP2D SULUTTENGGO PLN UP2D Suluttenggo adalah salah satu unit pelaksana dari PT. PLN (Persero) Unit Induk Wilayah Suluttenggo berkedudukan di Manado, yang pada awal pembentukannya sesuai dengan surat keputusan direksi Nomor : 0169.K/DIR/2015 tanggal 14 Agustus 2016 Tentang Organisasi PT PLN (Persero) Area Pengatur Distribusi Sulawesi Utara, Sulawesi Tengah dan Gorontalo pada PLN (Persero) Wilayah Sulawesi Utara, Sulawesi Tengah dan Gorontalo dan dalam perkembangan organisasinya berubah nama menjadi PLN Unit Pelaksana Pengatur Distribusi Suluttenggo disingkat UP2D. Daerah pelayanan PT PLN (Persero) UP2D Suluttenggo meliputi 3 Provinsi yaitu Sulawesi Utara, Gorontalo, dan Sulawesi Tengah dengan total luas wilayah pelayanan mencapai 88.128 km2. yang terbagi menjadi tujuh Unit Pelaksana Pelayanan Pelanggan (UP3) yaitu : 1. 2. 3. 4. 5. 6. 7.

UP3 Manado UP3 Kotamobagu UP3 Gorontalo UP3 Tolitoli UP3 Palu UP3 Luwuk UP3 Tahuna

1

PROFIL PLN UP2D SULUTTENGGO

PLN UP2D Suluttenggo dibagi menjadi 3 wilayah operasi yaitu UP2D Opsis 1, UP2D Opsis 2, dan DCC Gorontalo sesuai dengan peta wilayah kerja PT PLN (Persero) UP2D Suluttenggo pada gambar berikut : Peta Wilayah Operasi PLN UP2D Suluttenggo

PLN UP2D Suluttenggo bertanggungjawab atas pengoperasian dan pemeliharaan sistem distribusi 20 kV dan peralatan switching (Kubikel Gardu Hubung, LBS Motorized, dan Recloser) serta perangkat SCADA di peralatan tersebut. Berikut adalah data pengusahaan PLN UP2D sampai dengan bulan Desember 2018. Data Pengusahaan UP2D Suluttenggo

NO 1 2 3 4 5 6 7 8 9 10

URAIAN PMT 20 KV GI/PLTD BEROPERASI PMT 20 KV GI/PLTD (TERSCADA) GARDU HUBUNG GARDU HUBUNG (TERSCADA) KUBIKEL GH KUBIKEL GH (TERSCADA) KEYPOINT LBS MOTORIZED DAN RECLOSER KEYPOINT LBS MOTORIZED DAN RECLOSER (TERSCADA) PRK INVESTASI NILAI INVESTASI JASA DAN MATERIAL NON MDU (Rp Milyar)

2018 132 159 35 32 206 129 195 185 18 22,86

2

PROFIL PLN UP2D SULUTTENGGO

PRODUK YANG DITAWARKAN Kualitas dan Keandalan Sistem Distribusi Tegangan Menengah Sistem distribusi tegangan menengah merupakan subsistem tersendiri yang terdiri atas : Pusat Pengatur Distribusi (Distribution Control Centre/DCC), saluran tegangan menengah 20 kV yang merupakan saluran udara atau kabel tanah, peralatan proteksi, dan peralatan switching (Kubikel Gardu Hubung, LBS Motorized, dan Recloser). Keandalan merupakan tingkat keberhasilan kinerja suatu sistem atau bagian dari sistem untuk dapat memberikan hasil yang lebih baik pada periode waktu dan dalam kondisi operasi tertentu. Ukuran keandalan dan kualitas tenaga listrik yang pencapaiannya berada dalam lingkup kerja UP2D adalah : 1)

Kualitas tegangan PLN UP2D Suluttenggo melaksanakan operasi sistem distribusi dengan menjaga kualitas tegangan pada jaringan distribusi tenaga listrik tegangan menengah (TM) tetap berada pada range yang diizinkan dalam kondisi normal yaitu +5% dan -10%. Parameter kualitas yang juga menjadi perhatian adalah fluktuasi tegangan atau ketidakstabilan tegangan operasi. Fluktuasi tegangan seperti adanya tegangan lebih (over voltage), tegangan turun (drop voltage), dan tegangan getar (flicker voltage). Kondisi gangguan berupa fluktuasi tegangan ini akan mengakibatkan adanya resiko kerusakan pada peralatan dan menurunnya kualitas tenaga listrik yang dirasakan oleh pelanggan. Pengaturan tegangan untuk menjaga keandalan dan kualitas dilakukan dengan cara koordinasi sistem proteksi distribusi, pemeliharaan peralatan baik yang bersifat preventif maupun korektif, lokalisir titik gangguan, serta manuver tegangan untuk mengalihkan tempat gangguan atau beban melalui jaringan lainnya.

2)

Keseimbangan beban Ketidakseimbangan beban (unbalance voltage) umumnya terjadi di sistem distribusi karena adanya pembebanan fasa yang tidak merata. Kondisi ini juga dapat memicu munculnya masalah tegangan seperti yang sudah disebutkan di poin pertama di atas. Tindakan yang dilaksanakan oleh PLN UP2D Suluttenggo untuk mengurangi ketidakseimbangan beban ini adalah dengan melakukan perhitungan pemecahan beban distribusi yang kemudian dilanjutkan dengan melakukan pemasangan titik manuver berupa LBS atau Sectionalizer sesuai perhitungan untuk memudahkan pemecahan beban atau manuver jika terjadi kondisi tidak seimbang atau dibutuhkan pengaturan tegangan.

3

PROFIL PLN UP2D SULUTTENGGO

3)

Interupsi atau pemadaman listrik Interupsi ini dapat dibedakan menjadi : a.

b.

Pemadaman yang direncanakan (planned interruption/scheduled interruption), yaitu pemadaman yang terjadi karena adanya pekerjaan perbaikan atau perluasan jaringan pada sistem tenaga listrik, Pemadaman yang tidak direncanakan (unplanned interruption), yaitu pemadaman yang terjadi karena adanya gangguan pada sistem tenaga listrik seperti hubung singkat (short circuit), atau gangguan yang bersumber dari pembangkit dan transmisi yang berdampak ke sistem distribusi.

Untuk meminimalisir dampak dari interupsi ini PLN UP2D Suluttenggo melakukan langkah-langkah pengaturan operasi seperti : a.

b. c.

Pengaturan jadwal pekerjaan pemeliharaan berdasarkan kepada prioritas kebutuhan pemeliharaan dengan mengacu kepada laporan dan analisa kejadian gangguan pada operasi real-time. Pengaturan lokasi pemadaman otomatis untuk kejadian gangguan yang disebabkan oleh pembangkit dan transmisi Manuver tegangan jaringan distirbusi untuk mengalihkan sumber tegangan ke area yang terdampak padam atau untuk meminimalisir luas area yang terkena pemadaman.

SCADA (Supervisory Control And Data Acqusition) Untuk melaksanakan pengaturan sistem distribusi dalam mencapai kondisi operasi yang optimal dan efisien, PLN UP2D Suluttenggo melengkapi fasilitas pendukung keperluan pengaturan operasi dengan melakukan pemasangan dan pengelolaan perangkat SCADA dan telekomunikasi. SCADA pada sistem distribusi difungsikan mulai dari pengambilan data pada peralatan switching 20 kV yang berada di gardu induk (GI), pembangkit yang terhubung ke sistem 20 kV, sampai ke titik-titik manuver jaringan yang berada di GH, LBS/Sectionalizer, serta Recloser, kemudian dilanjutkan dengan pengolahan informasi yang diterima dan reaksi yang ditimbulkan dari hasil pengolahan informasi tersebut. Fungsi SCADA yang diambil dari setiap peralatan switching adalah : 1) 2) 3) 4)

Penyampaian data Proses kegiatan dan monitoring Fungsi kontrol seperti Open dan Close Perhitungan dan pelaporan

4

PROFIL PLN UP2D SULUTTENGGO

Data-data yang diambil dari setiap titik switching kemudian dikirimkan ke Master Station yang berada di DCC untuk menjadi panduan pengoperasian real-time oleh Dispatcher baik dalam kondisi normal maupun gangguan. Sedangkan fungsi telekomunikasi baik berupa telekomunikasi suara maupun data difungsikan untuk menghubungkan perangkat-perangkat sistem pengendalian khususnya antara Master Station dengan perangkat di Remote Terminal Unit (RTU) yang terpasang di setiap titik switching. Telekomunikasi suara digunakan sebagai media komunikasi dan koordinasi antara operator-operator pengatur sistem dan operator di lapangan. Dengan adanya perangkat SCADA dan telekomunikasi ini diharapkan dalam pengoperasian sistem distribusi tegangan menengah akan tercapai kondisi sebagai berikut : 1) 2) 3) 4) 5)

Kecepatan dan kemudahan dalam memperoleh data atau informasi yang dibutuhkan Penyajian data dan informasi bagi pengatur sistem sesuai dengan kondisi atau konfigurasi di lapangan Keandalan media data, terutama dalam kondisi gangguan Kemudahan komunikasi dalam koordinasi pengaturan sistem Kualitas data yang ditampilkan selalu merupakan kondisi yang mutakhir (terbaru).

5

PROFIL PLN UP2D SULUTTENGGO

STRUKTUR ORGANISASI PT PLN UP2D SULUTTENGGO MANAJER UP2D SULLUTTENGGO

SSII/AN/AS KINERJA

SEII/EN/AS PERENCANAAN PENGATUR DISTRIBUSI

MANAJER BAGIAN

MANAJER BAGIAN

MANAJER BAGIAN

MANAJER BAGIAN

PEJABAT PELAKSANA

PEJABAT PELAKSANA

FASILITAS OPERASI

OPERASI SISTEM DISTRIBUSI 1 1

OPERASI SISTEM DISTRIBUSI 2 1

KEU, SDM & ADM. 1

PENGADAAN

K3L

SUPERVISOR

SUPERVISOR

SUPERVISOR

SUPERVISOR

RTU DAN PERIPHERAL

PERENCANAAN DAN EVALUASI OPERASI

OPERASI

KEUANGAN DAN AKUNTANSI

AE/JE/AT/JT

AE/JE

AE/JE

AS/JA

PEMELIHARAAN RTU

PERENCANAAN OPERASI

PERENCANAAN OPERASI

KEUANGAN DAN AKUNTANSI

1

1

AN/AS

AE/JE/AT/JT

PELAKSANA PENGADAAN

K3L

OF/AF/JF

ADMINISTRASI PENGADAAN AE/JE/AT/JT

AE/JE

AO/JO/AE/JE

SUPERVISOR

INSTALASI INTERFACE RTU

EVALUASI OPERASI

PENGATURAN OPERASI

SDM DAN ADMINISTRASI

AE/JE/AT/JT

SUPERVISOR

AE/JE/AT/JT

POWER SUPPLY & PERLK. PENDUKUNG

OPERASI

ANALISA & EVALUASI GANGGUAN

AF/JF/AS/JA LOGISTIK

SUPERVISOR

AO/JO/AE/JE

SUPERVISOR

AF/JF/AS/JA

PERENCANAAN SCADA

PENGATURAN OPERASI

PEMELIHARAAN & PROTEKSI

ADMINISTRASI UMUM

AE/JE/AT/JT PERENCANAAN SCADA

SUPERVISOR

AE/JE/AT/JT

AE/JE/AT/JT

ANALISA & EVALUASI GANGGUAN

PEMELIHARAAN ELEKTROMEKANIK

SUPERVISOR

AE/JE/AT/JT

PENGELOLAAN DATA & GAMBAR

PROTEKSI

SCADA & TELEKOMUNIKASI

AE/JE/AT/JT

AE/JE/AT/JT

SUPERVISOR

DATA DAN GAMBAR

RTU & PERIPHERAL

SCADA & TELEKOMUNIKASI SUPERVISOR

AE/JE/AT/JT

PEMELIHARAAN ELEKTROMEKANIK

PEMELIHARAAN RTU

AE/JE/AT/JT

SUPERVISOR

PEMELIHARAAN ELEKTROMEKANIK

SCADA & TELEKOMUNIKASI

SUPERVISOR

AE/JE/AT/JT

PROTEKSI & METER

SCADA & TELEKOMUNIKASI

AE/JE/AT/JT

PROTEKSI

AE/JE/AT/JT

METER & TRANSAKSI ENERGI

SUPERVISOR

OPERASI DCC GORONTALO

AO/JO/AE/JE

PENGATURAN OPERASI

SUPERVISOR

PEMELIHARAAN & PROTEKSI

AE/JE/AT/JT

PEMELIHARAAN ELEKTROMEKANIK

AE/JE/AT/JT

PEMELIHARAAN RTU

6

PROFIL PLN UP2D SULUTTENGGO

PROFIL TENAGA KERJA Keragaman Tenaga Kerja UP2D SULUTTENGGO KELOMPOK PENDIDIKAN

KELOMPOK USIA

KELOMPOK LEVEL KOMPETENSI

URAIAN SD SLTP SLTA D1 D2 D3 S1 S2 S3 URAIAN ≤25 26 - 30 31 - 35 36 - 40 41 - 45 46 - 50 51 - 56 URAIAN ITG ADV OPT SYS SPE BAS

JUMLAH PEGAWAI 0 0 20 2 0 8 15 0 0 JUMLAH PEGAWAI 20 14 2 3 1 2 3 JUMLAH PEGAWAI 0 0 0 1 17 27

7

PROFIL PLN UP2D SULUTTENGGO

KELOMPOK JENIS KELAMIN

KELOMPOK JENJANG JABATAN

KELOMPOK STATUS

KELOMPOK PENSIUN

URAIAN PRIA

JUMLAH PEGAWAI 40

WANITA

5

URAIAN

JUMLAH PEGAWAI

MA MM MD SA SD F2 F3 F4 F5 F6

URAIAN

0 0 1 2 17 0 0 0 6 19 JUMLAH PEGAWAI

LAJANG

25

MENIKAH

19

LAINLAIN

1

2018

JUMLAH PEGAWAI 3

2019

1

2020

0

URAIAN

8

PROFIL PLN UP2D SULUTTENGGO

KESELAMATAN, KESEHATAN KERJA, KEAMANAN (K3) Komitmen PLN UP2D pada aspek K3 melibatkan setiap insan yang terlibat dalam kegiatan operasional PLN UP2D. Kebijakan dan standar K3 dipersyaratkan kepada seluruh pelaksana pekerjaan. Kebijakan pengelolaan K3 melalui implementasi Sistem Manajemen K3 (SMK3) sesuai PP No. 50 tahun 2012 dan Sistem Manajemen Pengamanan (SMP). Dalam menumbuhkan budaya sadar K3, PLN UP2D pada tahun 2017 telah melaksanakan assesmen SMK3 dengan hasil skor 94.57 dan pada tahun 2018 telah mendapatkan penghargaan Implementasi SMK3 dari Menteri Ketenagakerjaan RI untuk kategori tingkat lanjutan. ASET PLN UP2D Suluttenggo memiliki aset sebagai berikut, sebagian Aset ini belum sepenuhnya menjadi Aset riil UP2D Suluttenggo, karena sebagian masih asset milik Area dan belum semuanya tercatat di SAP: NO.

LOKASI

GH

1 2 3

MANADO KOTAMOBAGU GORONTALO TOTAL

17 7 11 35

LBS MOTORIZED RECLOSER REMOTE LOCAL TOTAL REMOTE LOCAL TOTAL 74 21 68 6 21 0 39 6 34 5 3 3 45 10 37 8 10 0 139 19 158 34 3 37

Data aset dalam rupiah sampai dengan 17 Desember 2018 : NO

ASET

RUPIAH

1 2 3

Bangunan & kelengkapan halaman Jaringan Distribusi Gardu Distribusi

4

Perlengkapan Lain-Lain Distribusi

2.826.529.200

5 6

Perlengkapan Pengelolaan Data Perlengkapan Telekomunikasi

33.596.947.642 308.622.200

7

Perlengkapan Umum Total

46.420.000 76.227.785.789

1.232.934.322 46.750.002 38.169.542.423

Pertumbuhan jumlah aset Distribusi UP2D Suluttenggo dan wilayah kerja yang luas serta tuntutan peningkatan pelayanan akan sangat berdampak pada pola pengoperasian sistem distribusi. Parameter SAIDI (System Average Interruption Duration Index), Recovery Time, Biaya Pokok Penyediaan, Susut, Penenkanan Biaya Pemeliharaan, Revenue, peningkatan mutu pelayanan serta citra PLN terhadap masyarakat wajib untuk dilakukan. Maka dalam

9

PROFIL PLN UP2D SULUTTENGGO

hal ini, dibutuhkan pengembangan struktur organisasi agar beban kerja pegawai seimbang dengan bertambahnya jumlah aset yang beroperasi dan perlu dipelihara untuk kontinyunitas pelayanan. Seiring dengan terbentuknya Sub Unit UP2D Opsis 2 untuk wilayah kerja Sulawesi Tengah (Area Palu, Area Luwuk dan Area Toli-Toli), dibutuhkan sistem operasional dan pemeliharaan terpadu. Sistem Operasional dan Pemeliharaan terpadu yang dimulai dari sisi Perencanaan, Pemeliharaan, Operasi Sistem, Fasilitas Operasi dan Sumber Daya Manusia (SDM). Tahun 2018, sistem SCADA Area Palu sudah mulai dibangun dengan Anggaran Investasi, antara lain Upgrade Master Station, Integrasi SCADA GI Palu – Poso, Scada GH Palu dan Integrasi Key point. Ditahun yang sama, area Luwuk yang sudah sudah memiliki Sistem Scada Mini (dibangun oleh Team UP2D pada tahun 2015), memulai menambahkan Key Point untuk terintegrasi dengan Scada dan pada tahun 2019 dalam usulan RKAP akan dilakukan Upgrade Master Station Area Luwuk. Sama dengan Area Luwuk, Area Toli-Toli pada Tahun 2019 juga diusulkan pembangunan Sistem Scada Mini . Berikut adalah Data Pengusahaan UP2D Suluttenggo dan beberapa grafik Pertumbuhan Asset UP2D dari tahun 2016 sampai dengan sekarang.

NO 1 2 3 4 5 6 7 8 9 10

URAIAN PMT 20 KV GI/PLTD BEROPERASI PMT 20 KV GI/PLTD (TERSCADA) GARDU HUBUNG GARDU HUBUNG (TERSCADA) KUBIKEL GH KUBIKEL GH (TERSCADA) KEYPOINT LBS MOTORIZED DAN RECLOSER KEYPOINT LBS MOTORIZED DAN RECLOSER (TERSCADA) PRK INVESTASI NILAI INVESTASI JASA DAN MATERIAL NON MDU (Rp Milyar)

2016 98 44 32 1 173 6 78 21 -

JUMLAH PER TAHUN RENCANA 2017 2018 2019 103 132 184 103 159 184 34 35 60 12 32 42 193 206 233 77 129 156 89 195 322 75 185 297 13 18 30 8,11 22,86 41,83

10

PROFIL PLN UP2D SULUTTENGGO

1. Jumlah PMT 20 kV GI / PLTD

2. Jumlah Gardu Hubung

3. Jumlah Kubikel Gardu Hubung

11

PROFIL PLN UP2D SULUTTENGGO

4. Jumlah LBS Motorized dan Recloser

5. Jumlah PRK Investasi

6. Jumlah Nilai Investasi Jasa dan Material Non MDU (RP. Milyar)

12

PROFIL PLN UP2D SULUTTENGGO

KOMUNIKASI PLN UP2D dalam berkomunikasi baik internal pegawai maupun dengan mengunakan berbagai media komunikasi baik secara langsung maupun tidak langsusng Internal :

Eksternal

1. Email 2. Group WA 3. CoC (Code of Conduct) 4. CMC (Coaching Mentoring Counseling) 5. Rapat 6. e-Porcelen

1. Email 2. Surat 3. Surat Kabar 4. e-Porcelen

PERBAIKAN KINERJA Perencanaan, Monitoring dan evaluasi pencapaian Kinerja PLN UP2D Suluttenggo dilakukan melalui : 1. Raker Rapat kerja dilaksanakan setiap triwulan atau sesuai kebutuhan dalam rangka mengevaluasi dan perencanaan kinerja 2. Rapat Bulanan Rapat yang dilaksanakan setiap bulan oleh manajemen dalam rangka mengevaluasi secara bulanan 3. 4DX Penerapan 4DX di PLN UP2D Suluttenggo ini membantu dalam pencapaian kinerja utama PLN UP2D Suluttenggo yaitu Waktu Remote Kontrol Pada Kesempatan Pertama Dibawah 4 Menit, % Kegagalan Proteksi Penyulang 20 kV, Meningkatkan Rasio Keberhasilan RC dari 96,94% ke 97,00%, Meningkatkan Keypoint Terintegrasi dari 0 ke 100. 4DX terdiri atas 4 Disiplin yang harus dijalankan secara terus-menerus yaitu: 1) Fokus pada sasaran paling penting (Focus on the wildly important goals-WIGs) 2) Bertindak berdasarkan lead measure (Act on the lead measure) 3) Terus menggunakan papan skor yang menggugah (Keep a compelling scoreboard) 4) Menciptakan irama pertanggung-jawaban (Create a cadence of accountability) 4. Budaya unggul Semanggi (Semangat Pagi) dan News Flash (Sekilas Info) Implementasi Program Budaya unggul Semanggi dan News Flash sebagai upaya untuk meningkatkan Engagement/Keterikatan pegawai di lingkungan PT. PLN (Persero). Program Semanggi (Semangat Pagi) adalah proses melayani pelanggan dalam hal ini pelanggan internal yakni pegawai, dimana setiap pegawai struktural membuat Job Delegation kepada semua bawahannya masing-masing, dalam form Job Delegation

13

PROFIL PLN UP2D SULUTTENGGO

setiap bawahan mengetahui tugas dan tanggung jawabnya masing-masing, support/dukungan masing-masing pegawai ke bagian lain dan target pelaksanaan pekerjaan. Sedangkan program News Flash (Sekilas Info) proses penyampaian informasi dan motivasi oleh senior leader kepada seluruh pegawai sehingga semua pegawai termotivasi dan merasa mendapat dukungan penuh dari Senior Leader dalam hal melaksanakan pekerjaan masing-masing.Serta merupakan salah satu upaya dalam hal memperoleh sosok Senior Leader yang dapat menginspirasi dan menjadi INFLUENCER di lingkungan kerja.

TANGGUNG JAWAB KEMASYARAKATAN Dalam berkomunikasi dengan pelanggan PLN UP2D Suluttenggo secara rutin melaksanakan pertemuan dengan masayarakat seperti berkunjung ke Universitas, SekolahSekolah Melalui UP2D Goes To Campus dan UP2D Goes To School juga masyarakat dilingkungan sekitar instalasi milik PLN UP2D Suluttenggo. PLN UP2D Melaksanakan penanaman pohon Mangrove di daerah pantai Likupang sebagai wujud kelestarian terhadap lingkungan hidup

ROAD MAP PLN UP2D SULUTTENGGO

14

PROFIL PLN UP2D SULUTTENGGO

Continuous Improvement 2018 - 195 Keypoint (LBS Motorized/Recloser) di SulutGo 158 LBS Motorized (136 terintegrasi SCADA) 37 Recloser (34 terintegrasi SCADA) - 35 Gardu Hubung di SulutGo (32 Gardu Hubung terintegrasi SCADA) - 206 Kubikel di SulutGo (129 terintegrasi SCADA)

Operational & Maintenance Excellent

Performance Excellent

2019 - Penambahan Keypoint : 76 LBS Motorized 9 Recloser

2020 - Penambahan Keypoint : 50 LBS motorized 13 Recloser

2021 2022 2023 - Penambahan Keypoint 21 Keypoint (LBS Motorized/Recloser)

- Pembangunan Gardu Hubung : Pembangunan 1 GH baru Pemasangan 27 kubikel baru Penggantian 11 kubikel lama

- Penggantian Kubikel GH : 29 kubikel

- Penggantian Kubikel GH : 25 kubikel

- Integrasi SCADA : 5 Gardu Induk/Extention 10 Gardu Hubung 63 Keypoint (LBS Motorized/Recloser)

- Integrasi SCADA : 9 Gardu Induk/Extention 7 Gardu Hubung 21 Keypoint (LBS Motorized/Recloser)

- Pemasangan 40 Disconnecting Switch di Tiang Pertama GI Sulteng - Implementasi SCADA Luwuk - Implementasi Mini SCADA Tolitoli - Go-Live APKT SCADA Sulteng - Implementasi CBM (Condition Based Maintenance )

- Pemasangan 40 Disconnecting Switch di Tiang Pertama GI Sulteng - Implementasi CBM (Condition Based Maintenance) - PERFORMANCE EXCELLENT

- Integrasi SCADA : 5 Gardu Induk 10 Gardu Hubung 108 Keypoint (LBS Motorized/Recloser)

- Integrasi APKT SCADA SulutGo - Persiapan Organisasi UP2D - Pembangunan SKTM untuk OPSIS 2 dan DCC Gorontalo perkuatan keandalan sepanjang 20,86 kms - Pembangunan 4 unit Repeater Link - Pemasangan 33 Disconnecting Switch di Tiang Pertama GI Kotamobagu dan Gorontalo - Upgrade Master Station SCADA Palu - Pembangunan Master Station SCADA Luwuk - Pembangunan Mini SCADA Sistem Tolitoli - Go-Live UP2D Opsis 2 dan DCC Gorontalo - Go-Live APKT SCADA Sulutgo - Integrasi APKT SCADA Sulteng - Pemeliharaan rutin menggunakan sistem KHS dengan menggunakan SLA

15

PROFIL PLN UP2D SULUTTENGGO

LAMPIRAN FOTO PLN Mengajar (PLN UP2D Goes To School)

Pelestarian Lingkungan (Penanaman Mangrove)

5R Gardu Hubung (Pemasangan Apar dan Kotak P3K)

16

Related Documents

Profil=
December 2019 59
Profil
November 2019 69
Profil
December 2019 57

More Documents from "Audyna ShidQi"