For Residential and Light Commercial Applications Job Name –––––––––––––––––––––––––––––––––––––––––––
Contractor ––––––––––––––––––––––––––––––––––––––––––––
Job Location –––––––––––––––––––––––––––––––––––––––––
Approval
Engineer –––––––––––––––––––––––––––––––––––––––––––––
Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––
Approval –––––––––––––––––––––––––––––––––––––––––––––
Representative
–––––––––––––––––––––––––––––––––––––––––––––
––––––––––––––––––––––––––––––––––––––––
HydroNex Z-Series Panel Sizes: 1-1/4" Trunk; 1" Stainless Steel Manifold Z Series panels are zone specific distribution panels. These panels include stainless steel manifolds to distribute water to radiant circuits, baseboard or other single temperature hydronic equipment. Z Panels are supplied with or without zone pumps, water temperature mixing, and zone actuators. All Z Series panels come pre-installed in a wall enclosure with lockable access cover. Z Series panels are available in 2-12 circuit configurations.
Installation Make sure an electrical outlet is within 3 feet of where the Z-Series panel will mount. If there are no outlets, one will need to be added. Install enclosure in 4-1/2” deep wall (minimum). ZPanels are available with or without the zone circulator. Non-pump ZPanels are designed to be used with P and D series Hydronex panels. ZPanels with pumps are zone based panels designed on the assumption the main mechanical room piping will be field constructed. Options for ZPanels include mixing devices, circulators, manifolds, differential by-pass valves, vent/purge assemblies, and individual thermal actuators, depending on the style chosen. 1. 2. 3. 4. 5. 6. 7.
Remove and set aside the door. Adjust box height. Adjust frame depth to wall requirements. Secure the Main Box in the frame wall. Secure the manifold brackets to the Manifold Support Bracket using the Locking Rail Nut and Hex Head Bolt. Knock out the supply /return knock-outs on either side, as needed. Install the door frame by resting it on the lower rail of the frame and lift. Secure door via the lock.
Features – Wall mounted white powder coated enclosure with locking access cover. – Pre-wired actuators (specific models only). – Fully enclosed circulator and/or mixing valve (specific models only). – Stainless Steel manifolds.
Specifications Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Volts Circulator Type . . . . . . . . . . . . . . . . . . . . .Watts Radiant 15-58 Electrical . . . . . . . . . . . . . . . . . . . . . . . . . Zone Valve Relay Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Isolation Relay
Refer to the installation manual for further details.
Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
Hydronex Z-Series Basic.
Hydronex Z-Series Pump with actuators and differential by-pass valve.
Hydronex Z-Series Pump Mix with actuators and differential by-pass valve.
Product Options Qty.
Description
Part #
Order #
Panel Size
2 Circuit Stainless Steel Manifold 3 Circuit Stainless Steel Manifold 4 Circuit Stainless Steel Manifold 5 Circuit Stainless Steel Manifold 6 Circuit Stainless Steel Manifold 7 Circuit Stainless Steel Manifold 8 Circuit Stainless Steel Manifold 9 Circuit Stainless Steel Manifold 10 Circuit Stainless Steel Manifold 11 Circuit Stainless Steel Manifold 12 Circuit Stainless Steel Manifold
ZZone2 ZZone3 ZZone4 ZZone5 ZZone6 ZZone7 ZZone8 ZZone9 ZZone10 ZZone11 ZZone12
81005851 81005852 81005853 81005854 81005855 81005856 81005857 81005792 81005793 81005794 81005795
29.25" x 25.5" x 4.5" 29.25" x 25.5" x 4.5" 29.25" x 25.5" x 4.5" 29.25" x 25.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5"
2 Circuit Stainless Steel Manifold with ZonePump 3 Circuit Stainless Steel Manifold with ZonePump 4 Circuit Stainless Steel Manifold with ZonePump 5 Circuit Stainless Steel Manifold with ZonePump 6 Circuit Stainless Steel Manifold with ZonePump 7 Circuit Stainless Steel Manifold with ZonePump
ZPumpZone2 ZPumpZone3 ZPumpZone4 ZPumpZone5 ZPumpZone6 ZPumpZone7
81005865 81005866 81005867 81005868 81005869 81005870
29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5"
2 Circuit Stainless Steel Manifold, ZonePump, Mix Valve 3 Circuit Stainless Steel Manifold, ZonePump, Mix Valve 4 Circuit Stainless Steel Manifold, ZonePump, Mix Valve 5 Circuit Stainless Steel Manifold, ZonePump, Mix Valve 6 Circuit Stainless Steel Manifold, ZonePump, Mix Valve 7 Circuit Stainless Steel Manifold, ZonePump, Mix Valve
ZMixPumpZone2 ZMixPumpZone3 ZMixPumpZone4 ZMixPumpZone5 ZMixPumpZone6 ZMixPumpZone7
81005879 81005880 81005881 81005882 81005883 81005884
29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5" 29.25" x 41.5" x 4.5"
Differential By-Pass Valve Thermal Actuator
D4402050 PZ656104
81005345 81001541