05-349-952-34-05

For Residential, Light Commercial, and Snowmelt Applications Job Name –––––––––––––––––––––––––––––––––––––––––––

Contractor ––––––––––––––––––––––––––––––––––––––––––––

Job Location –––––––––––––––––––––––––––––––––––––––––

Approval

Engineer –––––––––––––––––––––––––––––––––––––––––––––

Contractor’s P.O. No. –––––––––––––––––––––––––––––––––––

Approval –––––––––––––––––––––––––––––––––––––––––––––

Representative

–––––––––––––––––––––––––––––––––––––––––––––

––––––––––––––––––––––––––––––––––––––––

HydroNex P-Series Panel Sizes: 1-1/4" Trunk P-Series Panels are primary panels designed to supply down-stream panels with boiler water, which will in turn distribute boiler water to the radiant or other hydronic heating zones. They also remove air and provide essential service and monitoring capabilities. They are available with or without outdoor boiler reset controls and auto-fill assemblies. D-Series and P-Series panels include only the supply portion of the primary loop. The return portion of this loop must always be field piped in 1-1/4” copper back to the boiler or dedicated heat source. All P-Series panels are designed to connect directly to any D-Series panel via the included union. Control logic is transferred from the D-Series panels to the P Panel via the included CAT5 cable connection. Optional accessories include auto-fill assembly (shown) and a boiler reset module. Reset should not be used if using an injection D Series panel as these already contain a reset feature on the included Tekmar 361.

Installation Make sure an electrical outlet is within 3 feet of where the P-Series panel will mount. If there are no outlets nearby, one will need to be added. Install and level Z-Bracket with 1/4” x 2-1/2” lag screw to studs. Hang the P-Series panel on the Z-Bracket. Optional lag screws may be added to the bottom of the panel, further securing the panel to the wall. Hang cover from top down. If using injection mixing D-Series panel, do not use reset on the P-Series panel. Refer to the installation manual for further details.

Features – Wall mounted white powder coated back panel and cover. – Easy access to all components. – Pre-wired circulators and controls. – Simple CAT 5 jump wiring to connect panels. – Single union connection between panels. – Integrated leveling system. – Z-Bracket for simplified mounting.

Specifications Supply Voltage . . . . . . . . . . . 120 Volts Circulator Type. . . . . . . . . . . . Watts Radiant 15-58 . . . . . . . . . . . . . . . . . . . Taco 008, 0011 . . . . . . . . . . . . . . . . . . . Bell and Gossett NRF-22, PL-30 Fill Assembly . . . . . . . . . . . . . Manual Only . . . . . . . . . . . . . . . . . . . Manual and Autofill Electrical . . . . . . . . . . . . . . . . Relay and CAT 5 Connection Reset Control . . . . . . . . . . . . Tekmar 256

Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

Hydronex P-Series with a manual fill assembly.

Hydronex P-Series with an autofill and manual fill assemblies.

Product Options Qty.

Description

Part #

Order #

Panel Size

P Panel, Manual Fill, Watts Radiant 15-58 Pump P Panel, Manual Fill, Taco 008 Pump P Panel, Manual Fill, Taco 0011 Pump P Panel, Manual Fill, Bell & Gossett NRF-22 Pump P Panel, Manual Fill, Bell & Gossett PL-30 Pump P Panel, Auto Fill, Watts Radiant 15-58 Pump P Panel, Auto Fill, Taco 008 Pump P Panel, Auto Fill, Taco 0011 Pump P Panel, Auto Fill, Bell & Gossett NRF-22 Pump P Panel, Auto Fill, Bell & Gossett PL-30 Pump

PManWR1558 PManTA008 PManTA0011 PManBGNRF22 PManBGPL30 PAutoWR1558 PAutoTA008 PAutoTA0011 PAutoBGNRF22 PAutoBGPL30

81005806 81005808 81005809 81005810 81005811 81005800 81005802 81005803 81005804 81005805

28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5”

P Panel, Manual Fill, Outdoor Reset, Watts Radiant 15-58 Pump P Panel, Manual Fill, Outdoor Reset, Taco 008 Pump P Panel, Manual Fill, Outdoor Reset, Taco 0011 Pump P Panel, Manual Fill, Outdoor Reset, Bell & Gossett NRF-22 P Panel, Manual Fill, Outdoor Reset, Bell & Gossett PL-30 P Panel, Auto Fill, Outdoor Reset, Watts Radiant 15-58 Pump P Panel, Auto Fill, Outdoor Reset, Taco 008 Pump P Panel, Auto Fill, Outdoor Reset, Taco 0011 Pump P Panel, Auto Fill, Outdoor Reset, Bell & Gossett NRF-22 P Panel, Auto Fill, Outdoor Reset, Bell & Gossett PL-30

PManRWR1558 PManRTA008 PManRTA0011 PManRBGNRF22 PManRBGPL30 PAutoRWR1558 PAutoRTA008 PAutoRTA0011 PAutoRBGNRF22 PAutoRBGPL30

81005895 81005896 81005897 81005898 81005899 81005900 81005901 81005902 81005903 81005904

28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5” 28” x 31.5”

USA: 4500 East Progress Place, Springfield, MO 65803; www.wattsradiant.com Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca