SYSTEM PANELCONTROL SYSTEM PANELCONTROL PROVIDES. -AUDIBLE & VISUAL INDICATIONS OF ALARMS & ADVISORIES ON SYPD & SYSD . -DISPLAYS C.P. LOAD. -DISPLAYS EXTERNAL ALARMS -IN EWSD SYSTEM FAULT DETECTION, FAULT ANALYSIS AND SIGNALLING IS DONE BY THE SYSTEM . -THEN ALARM CONFIRMATION AND FAULT CLEARANCE IS THEN PERFORMED BY THE MAINTENANCE STAFF. .

1

TOPICS FOR DISCUSSION A. OVERVIEW OF SYSTEM PANEL CONTROL C. SYSTEM PANEL CONTROL MODULE D. ALARM LEVELS. E. FUNCTIONS OF KEYS & LEDS OF SYPD. E. SUPERVISION OF SYP. F. OPERATING STATUS OF SYP. G. ADMINISTRATION OF SYP ALARMING 2

Subs

LTG:B

DLU

Dig: Trunks

LTG:C CCNC

SYPD

SN MB

SYPC

CP CCG

SYSD

OMT MDD

MTU ALARAM CONSOLE

PRINTER

3

LED of System Panel Display

Month

Day

Time Fire

Line/trunk

Switching network SN

4

groups LTG 3

:

-

2

5

1

Maintnance Service External alarm equipm alarm

Coordination porcessor CPCentral units ERL

Processor load System Panel SYP Update

External alarms

16

32

DC power supply 17 Air conditioning 18

Message 8 9

Text Accept

31

supervision

33

Power failure

7

Common channel buffer signalling 6

Trunk group alarm Line lockout Sinnaling links Call idnentification

11 12 13 14

Trunk group External 27 DLU alarms blocked Cat.1 28 AdministraCat.2 tive alarm 29 Recovery System operator 30 Time insecure

SYSTEM PANEL

34 35

19

Clock

10

Entry 15

36

20 21

37

22

38

23 HW units

39

Signalling

24 links blocked 40 Alarm

25 Indications 41 26

Suppressed

42

4

Type of

Horn R L 2 LEDs

1 LED

signalalarm Critical

Alternating flashing at

unaccepted

f=2.5 Hz

Continuous f=488 Hz off

accepted at SYPD

f=2.5 Hz

off

accepted by MML command Major alarm unaccepted accepted at SYPD by command

--------

f=1.25 Hz

Flashing at f=2.5 Hz f=2.5 Hz

accepted f=1.25 Hz MML

off

Flashing at Hz

Clocked tone

f=2.5 800/800 ms off

f=2.5 Hz

off

f=1.25 Hz 5

Minor alarm

off

unaccepted

Continu Continuous -ous

accepted at SYPD

Pulse * 800 ms

Continuous

accepted by MML command Indication

Continu- Continuous ous

off

ContinuContinuous ous

Off

6

ALARM LEVELS. THERE ARE THREE LEVELS OF ALARMS:A. CRITICAL ALARMS - REPRESENTS SERIOUS DEGRADATION OF SERVICE. B. MAJOR ALARMS -

NO DIRECT INFULENCE ON SERVICE.

C. MINOR ALARMS -

NO EFFECT ON SERVICE.

-

ALARM WITH HIGHEST PRIORITY FOR A FUNCTIONAL UNIT DISPLAY FIRST AT SYPD.

-

CRITICAL ALARM IF NOT ACCEPTED WITHIN 5 MINUTES, THE HORN SOUNDS AT MAXIMUM 7 VOLUME.

CRITICAL ALARMS IT REPRESENTS SERIOUS DEGRADATION OF SERVICE REQUIRES IMMEDIATE ACTION FROM O & M PERSONAL. THIS ALARM APPEARS WHEN ACTIVE & REDUNDANT EQUIPMENT HAVE FAILED . IN THIS TWO LEDS FLASH ALTERNATELY AND HORN SOUNDS CONTINUOUSLY. EXAMPLES: •

SN0 / SN1 HAVE FAILED & ONE OF THEM IS IN OPERATING STATE UNA.



BOTH DLU SYSTEM 0 & 1 HAVE FAILED & ONE OF THEM IS IN OPERATING STATE UNA.



CP TO SYPC INTERFACE IS FAULTY . 8

MAJOR ALARM •MAJOR ALARM HAS NO DIRECT INFULENCE ON SERVICE. •BUT THIS KIND OF ALARMS HAS TO BE TREATED IMMEDIATELY SINCE REDUNDANT SYSTEM UNIT HAS FAILED. •

IN THIS CASE LEFT LED OUT OF TWO LEDS AND SINGLE LED FLASH AND HORN GIVES A CLOCKED TONE OF 800/800 ms .

EXAMPLES. •

SN0 OR SN1 IS IN OPERATING STATE UNA.



ONE CCG IS IN OPERATING STATE UNA.



ONE SYPD IS FAULTY. 9

MINOR ALARM ON

MINOR ALARM HAS LITTLE OR NO INFLUENCE SERVICE.

IN THIS CASE HORN SOUNDS FOR 800 ms ONLY, SINGLE LED LIGHTS AND RIGHT LED OF THE TWO LEDS LIGHTS.

EXAMPLES: • -

ONE OF THE FOLLOWING FAULT HAS OCCURRED ON A PCM LINK OR IN A DLU. ALARM INDICATION SIGNAL IN MULTIFRAME. -ALARM INDICATION SIGNAL IN PULSE FRAME

10

FUNCTIONAL OVERVIEW OF SYSTEM PANEL SYSTEM PANEL CONSISTS OF :(I)

SYSTEM PANEL CONTROL (SYPC), WHICH IS HOUSED IN R:MB/ CCG

(II)

SYSTEM PANEL DISPLAY (SYPD) / (SYSD). THERE CAN BE A MAXIMUM OF 8 SYPDs. ONE IS CONFIGURED AS MASTER. HOWEVER SEVERAL OR ALL CAN BE CONFIGURED AS MASTER IN EXCEPTIONAL CASES. ALARMS AND INDICATIONS APPEAR SIMULTANEOUSLY ON ALL SYPDs. GENERALLY ONLY ONE SYPD IS PROVIDED 11

D C C

I O C S Y P C

C O M S Y P C

R M E A

T/ T/ T RM RM X A S S S Y Y Y

C D E X 0

C D E X 1

C C C C C D D D D D E E E E E X X X X X 2 3 4 5 6

C D E X 7

C C D D D E E C X X C 8 9

P P P C C C Module frame 0 A1for system panel control, F:SYPC

12

SYP SYPD0

7-segment displays

LEDs

Display

Pushbutton Panel

External horn*)

Internal horn

•• •

To up 24 to external signaling units*) Tofault up 24 to external SYPC

supervisory units

IOP:MB0

•• • • ••

SYPD 1 TO 3

SYPD 1 TO 7

IOP:MB1

Structure of the system panel

13

FUNCTION OF KEYS & LEDs OF SYPD PUSH BUTTON KEYS 1.

UPDATE KEY

2.

TEST KEY

3.

ACCEPT KEY

PRESSING ACCEPT KEY SWITCHES OFF HORN, BUT DOES NOT ACTULLY ACCEPT ALARM.

7-SEGMENT DISPLAY -TIME -MONTH-DAY -PROCESSOR LOAD (UPDATED EVERY 4 SEC. )

SYSTEM DISPLAYS

14

ACCEPT KEY IS PROVIDED ON EACH SYPD. PRESSING OF ACCEPT KEY STOPS THE AUDIBLE SIGNAL OF PARTICULAR SYPD. PRESSING ACCEPT KEY Of MASTER SYPD CAUSES AUDIBLE SIGNAL TO BE SWITHCED OFF CENTRALLY BY THE CO-ORDINATION PROCESSOR . IN CASE OF ALARM AT SYPD DUE TO FAULT, THE OBJECT CAN BE LISTED WITH

DISP ALARM IN CASE OF INDICATIONS, CAUSED BY CONFIGURATION OF HW UNIT TO STATE MBL OR CBL , THE LIST OF HWUNITS CAN BE DISPLAYED BY

DISP INDIC: 15

LEDS & DIGITAL DISPLAYS SYSTEM PANEL DISPLAY IS DIVIDED INTO SIX FUNCTIONAL AREAS. 1.

LINE/TRUNK GROUP

2.

SWITCHING NETWORK

3.

CO-ORDINATION PROCESSOR

4.

SYSTEM PANEL

5.

EXTERNAL ALARMS

6.

MISCELLANEOUS FUNCTIONS

THERE IS DIGITAL DISPLAY OF MONTH, DAY, TIME & PROCESSOR LOAD. 16

SUPERVISION OF SYP CP (IOP: MB) SUPERVISED BY CP & SYPC I.E. CP SUPERVISES SYPC & SYPC SUPERVISES QP SELFSUPERVISION

SYPCO

SYPC

SYPCN

MODULE ALARMS & ITS MEANING

SUPERVISED BY CP & SYPC I.E. CP SUPERVISES SYPD & SYPD SUPERVISES SYPC

LEP - SYP IS FLASHING - > SYPC HAS DETECTED THE UNAVAILABILITY OF ONE SYPD & INDICATES THIS ON17 ALL OTHER SYPD.

LED - SYD & LED – CP ARE FLASHING AT ALL SYPD SYPC HAS NO CONNECTION TO CP . (INTERFACE OR CP PROBLEM)

LED- SYP IS FLASHING & CP- LOAD SEGMENT IS OFF THIS SYPD HAS POWER BUT NO CONNECTION TO SYPC. (IF THIS HAPPENS TO ALL SYPD, THEN SYPC IS FAULTY).

18

SYSTEM PANEL CONTROL MODULES SYPC IS NOT DUPLICATED & IS INSTALLED IN F: SYPC

IOC: SYPC IT IS USED TO CONNECT SYPC TO CP . ON THIS INTERFACE IT RECEIVES NECESSARY DATA FROM CP. IT USES THESE DATAS TO DETERMINE SIGNALS I.E. CRITICAL /MAJOR OR MINOR ALARMS / DAY /TIME OR PROCESSOR LOAD.

RM : FA RECEIVES EXTERNAL ALARMS DIRECTLY VIA THE EXCHANGE OR MDF. IT SUPPLIES DATAS TO SYPC, THE OST OF EXTERNAL EQUIPMENT. 19

COM : SYPC PROCESSOR OF SYSTEM PANEL CONTROL

TXA : SYPC ALLOWS SYPD SIGNALLING TO BE FORWARDED TO EXTERNAL FAULT DEVICE

T/RM: SYPC TRANS / RECEIVES MODULE T/RM0 : SYPC --- > SYPD0 ---- SYPD3 T/RM1 : SYPC ----> SYPD4 ---- SYPD7

20

Administration of External Alarm Lines and Texts EAL DLU EXCH DLU A L E DLUC X

LTG

GP SYPD

EAL EXCH

SN

SYPC RM:EA

OMT

CP

SGC 21

Administration of External Alarm Lines (FOR EXCH SITE) SYPC 0 • Contect • RM: •

(e.g• EA door) 23

CP

COM: SYPC

User EPROM

SYPD

OMT 22

ASSIGNMENT OF INDIVIDUAL EXTERNAL ALARM LINES (EAL) TO THE PINS OF THE MODULE RM:EA

EDL No.

1 2 3 4 5 6 7 8 9 10 11 12

PIN No.

SYPD- LED

EDL No.

RE:EA

34567891011121314-

15 16 17 18 19 20 21 22 31 32 33 34

13 14 15 16 17 18 19

PIN No.SYPD- LED

4344454647 48 49 50 51 52 53 54

35 36 37 38

23

OPERATING STATUS OF SYP

STAT SYP ; UNA MBL ACT HOW TO CONTROL REPORT/ALARM MESSAGES ON OMT-0

ACTOUTSUP; DACTOUT SUP:DEVICE = SYSTEMDEVICE-FUOMT; . 24

ADMINISTRATION OF SYP ALARMING I. ALARM PRIORITIES DISP ALPRIO ; ENTR ALPRIO II. ALARM MODE USED FOR TWO SERVICE FEATURES

STATUS AND HLIM

DISP ALMODE ; ENTR ALMODE III. ALARM DISPLAYS DACT ALDISP; ACT ALDISP;

25

LEVELS FOR EXTERNAL DLU ALARMS

DISP EAL LVL : DLU=-----, EAL= ---; CR EAL LVL : DLU = -------

(910 TO 2550)

EAL = -------

(! TO 16)

LVL = -------

(HIGH /LOW )

26

ALARM AND ARCHIVE FILES HF ARCHIVE

(SYSTEM ARCHIVE FILE)

- STORES ALL MAINTENANCE MESSAGES OF THE SYSTEM - CONTAINS ADDITIONAL INFORMATION ALSO WHICH IS REQUIRED FOR SPECIAL FAULT CLEARANCE BY THE SYSTEM SPECIALIST E.G RECOVERY MESSAGE, AUDIT MESSAGES. -HF ALARM IS A DUIPLICATED CYCLIC FILE. HOW TO READ THE CONTENTS OF ANY ARCHIVE FILE

DISP AENTRY: AFILE=--- , [AENTRY] = ,[TOC]= ; SEL AENTRY : AFILE = , [TIME]= ,[ DATE] = MSG = , [ALPRIP] =---; [ DIR= ]!

27

CR A FILE

AM . ALARM

ALARM FILE

- CONTAINS ALL FAULT MESSAGES WHICH BELONG TO NOT YET CLEARED SYPD ALARMS - CAN ONLY BE READ BY THE OPERATOR WITH COMMAND DISP/SRCH ALARM

THE

- IS A DUPLICATED SYSTEM FILE AUTOMATICALLY CREATED BY THE SYSTEM. - TO READ THE CONTENTS OF AM. ALARM FIL; DISP ALARM : [OBJECT = ] [ ALSTAT=] [ ALPRIO=] SRCH ALARM: [OBJECT=] [ ALSTAT=] [ALPRIO=] [MSGNO=]

28

ASSIGN ALARM TEXT AND ALARM PRIORITY DLU CR EAL SITE = ------

( EXCH / DLU )

EAL = ----- (1 TO 24 FOR EXCH OR 1 TO 16 FOR DLU ) TEXTNO. =

---- (1 TO 40)

ALPRIO = ------( CRITICAL / MAJOR / MINOR )

DISP / CAN EAL SITE = ------

( EXCH / DLU )

EAL = ----- (1 TO 24 FOR EXCH OR 1 TO 16 FOR DLU )

29

ENTER / CANCEL ALARM TEXT ASSIGNMENT DISP AL TEXT : TEXTNO =XX; ENTR AL TEXT : TEXTNO =XX (1 TO 40 ), TEXT=“--”; CAN AL TEXT : TEXTNO =XX;