National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Item Address
Details of location
Type of building
Service provided
Public accommodation
Bedroom accommodation
1
Present situation
Proposed future development
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Item
Present situation
Staffing
Management
Proposed future development PT
FT
Date PT
FT
Reception
Catering
Cleaning
Gardener/Maintenance/General
2
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 1 Pre-arrival, arrival & reception
Accessibility standards for M3i, M3a & AE
M3/ AE
Advertising to contain information on equipment and services
M3/ AE
Lower section of reception and or separate desk or clipboard provided. 800mm height, 750mm wide, 500mm deep
M3/ AE
Reception clutter free Unobstructed space 1200x1200mm recommend 1500x1500mm
M3/ AE
Lighting diffuse, non glaring and appropriate
M3/ AE
Facilities available made known to guests on or prior to arrival
M3/ AE
Familiarisation tour offered Key to accessible facilities provided Larger properties to have signage to facilities
M3/ AE
3
Additional room key
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 1 Pre-arrival, arrival & reception (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Written record of guest
M3/ AE
Familiar with BS 5588 part 8: Means of escape for disabled people
M3/ AE
Fire evacuation point indicated and access clear
M3/ AE
Evacuation procedures agreed with guest
M3/ AE
If entry is by phone it must be 900 1200mm high
Present situation
Intended action
Cost
Date
requirements and room number
4
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
5
Standard
Section 2 Ramps (must be provided)
Accessibility standards for M3i, M3a & AE
M3
Maximum gradient 1:12, recommend 1:15 Maximum length 10m, rise no greater than 500mm
AE
Gradient 1:15, 1:12 if shorter than 2m long
M3
Minimum width 1.2m (Width 750mm if shorter than 2m long)
M3/ AE
Total series no more than 2m high
M3i
Landings min 1.2m long
M3a/ AE
Landings min 1.5m long
M3/ AE
Raised edge at least 100mm along any open edge.
M3/ AE
A continuous handrail as Section 4
M3/ AE
Slip resistant finish
M3/ AE
Good, evenly distributed lighting at night
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 3 Steps
Accessibility standards for M3i, M3a & AE
M3/ AE
Handrails
Stepped alternative provided
AE
No projecting nosing. Risers closed.
AE
Uniform height (max 170mm), no less than 250mm deep. Depth more than height
AE
Landing at least 1.2m between sets/flights
Standard
Accessibility standards for M3i, M3a & AE
M3/ AE
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
Ramp or level access
AE
Section 4
Present situation
Where practical continuous handrails should be provided on both sides of steps, stairs and ramps. At least one rail provided
M3
Recommend height 900mm1000mm (stairs, ramps), 900mm1100mm (landings)
AE
Height 900mm-1000mm (stairs, ramps), 900mm-1100mm (landings)
6
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
7
Standard
Section 4 Handrails (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Handrails should extend horizontally 300mm beyond the top and bottom of each flight and terminate with a closed end that does not project into a pedestrian route (where practical and safe)
M3/ AE
Handrails easy to grip.
M3
Recommend with a diameter of 40mm-50mm
AE
Diameter 40mm-50mm
M3
Recommend the gap between handrail and wall to be between 50mm-60mm
AE
Gap between handrail and wall between 50mm-60mm
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 5 Approach/ car parking
Accessibility standards for M3i, M3a & AE
M3/ AE
Lighting around bays and route to entrance.
M3i
If parking not in close proximity to entrance a setting down point as close as possible to the entrance with dropped kerb required
M3a
Setting down point required with dropped kerb
AE
Setting down point with dropped kerb at all entrances
M3
The route from the setting down point to the entrance should be free from steps, smooth, no gradient over 1:12 and slip resistant.
AE
Route free from steps, less than 1:15 gradient or flat, firm, slip resistant and smooth surface.
M3/ AE
Where parking is provided a reserved bay at least 3.6m wide should be located as close as possible to the entrance or entrance route.
M3/ AE
One parking space per accessible bedroom.
Present situation
Intended action
Cost
Date
8
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Section 5 Approach/ car parking (cont.)
Standard
Accessibility standards for M3i, M3a & AE
M3/ AE
Parking bays should allow for rear access to vehicle.
M3
Recommend covered area for transfer to wheelchair
AE
Covered area for transfer
M3/ AE
Maximum distances from car park to entrance: Covered 100m Open-air 50m
M3/ AE
Designated bay and entrance clearly signposted
AE
Number to call for assistance visible from parking bay
Standard
Section 6 Thresholds
9
Accessibility standards for M3i, M3a & AE
M3
Recommend flush thresholds throughout but should not exceed 25mm. If more than 5mm the threshold should have chamfered or pencil round edges.
AE
Thresholds must be flush
Present situation
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 7 Doors main entrance and internal (refer to table page 41)
Accessibility standards for M3i, M3a & AE
M3
AE
Where possible, automatic doors with delay mechanism provided.
M3/ AE
Easily operated, prefer push door or double acting.
M3
Recommend allow 300mm between wall and door. Allow 300mm between wall and door
M3/ AE
Door handles, lock and key holes
Cost
Date
Present situation
Intended action
Cost
Date
Recommend open door edge to corridor wall min 750mm
Standard
Section 8
Intended action
Minimum single leaf clear opening not less than 750mm, recommend 800mm. Turning space outside door not less than 1200mm Minimum single leaf clear opening not less than 850mm. Turning space outside door not less than 1200mm recommend 1500mm
AE
AE
Present situation
Accessibility standards for M3i, M3a & AE
M3/ AE
Door handles easy to grip with minimal twist.Horizontal pull or lever action 900mm-1200mm above floor level
M3/ AE
Long vertical pull handles acceptable in public areas.
M3/ AE
Lock and keyholes 900mm1200mm above floor level
10
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 9 Interior – general (for reception refer to Section 1)
Accessibility standards for M3i, M3a & AE
M3/ AE AE
Internal passageways & corridors
11
Cost
Date
Present situation
Intended action
Cost
Date
Seating available Accessible facilities clearly signed and read from wheelchair
AE
Signs at an accessible height for all Lighting appropriate for purpose intended
Standard
Section 10
Intended action
Fixed, slip resistant floor surface Avoid rugs and mats
M3/ AE
M3/ AE
Present situation
Accessibility standards for M3i, M3a & AE
M3/ AE
Corridors must be clutter free, have an unobstructed width not less than 1200mm (SC 850mm).
M3
Permitted narrowing to 800mm for no more than 1500mm at the location of immovable structural or service items (eg radiators, fire extinguishers).
AE
Permitted narrowing to 900mm for no more than 1500mm at the location of immovable structural or service items (eg radiators, fire extinguishers).
M3/ AE
Protrusions or overhangs removed. Care taken with housekeeping trolley/items.
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 11 External paths and roadways
Accessibility standards for M3i, M3a & AE
M3/ AE
Present situation
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
Routes to all facilities firm, sound and free from obstacles No incline/ramp steeper than 1:15 (1:12 existing) Where path longer than 15m resting places every 10m, at least 900mm wide No steps unless ramped alternative. Level gap at least 750mm in speed limiting devices.
AE
Standard
Section 12 Lifts (where provided)
Footpaths to all facilities, no gradient steeper than 1.20, no longer than 10m.
Accessibility standards for M3i, M3a & AE
M3
Door clear opening width not less than 750mm, recommend 800mm.
AE
Not less than 850mm
M3
Space outside, opposite door not less than 1200mm, recommend 1500mm
M3
Recommend a grab rail or handrail to at least one side of the lift car 900mm-1200mm above the floor.
AE
Grab or handrail on at one side 900mm-1200mm above floor.
12
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 12 Lifts (where provided) (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Lift with automatic doors or purpose built for wheelchair users
M3/ AE
Lift car minimum 1400mm deep x 1100mm wide
M3/ AE
All controls between 900mm1200mm above floor and minimum 400mm from return wall.
M3i
Recommend where only one entrance, mirror fitted to back wall, bottom max 900mm above floor level.
AE
Where only one entrance, mirror to be fitted to back wall, bottom max 900mm above floor level.
Standard
Section 13 Switches, control panels, power sockets, window catches, hairdryers, hooks and curtain pulls.
13
Accessibility standards for M3i, M3a & AE
M3/ AE
Height 900mm-1200mm
Present situation
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 14 Bedrooms
Accessibility standards for M3i, M3a & AE
M3
AE M3 AE
Present situation
Intended action
Cost
Date
Door clear opening width not less than 750mm, recommend 800mm Not less than 850mm. Space outside, opposite door not less than 1200mm Not less than 1200mm, recommend 1500mm
M3 AE
Unobstructed space 1200x1200mm Unobstructed space 1500x1500mm
M3/ AE
Firm bed surface between 450mm540mm above the floor. Height adjustment to be available if necessary. Bunk/sofa/folding beds not acceptable.
AE
Recommend electronically operated bed
M3a /AE
Clear space of 150mm under bed
M3i
800mm unobstructed transfer space to one side of the bed. Full length of bed unobstructed.
M3a/ AE
Unobstructed transfer space to one side of the bed 900 x 1500mm clear space for turning mobile hoist. Full length of bed unobstructed.
M3/ AE
Recommend moveable furniture eg. ziplink
14
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
15
Standard
Section 14 Bedrooms (cont.)
Accessibility standards for M3i, M3a & AE
M3
AE
Unobstructed route to all principle furniture and fittings at least 800mm wide, recommend 900mm At least 900mm
M3/ AE
TVs must have remote control. Recommend subtitles.
M3
Bedside lights within reach of head end of beds – Max 500mm stretch (switches to be easily reached)
AE
Main lights to be controllable from the bed.
M3/ AE
Tables/desk to have underspace 650 high and 750mm wide. Work surface height max 850mm
M3/ AE
Chair with rigid arms available
M3/ AE
Where provided spy holes in doors between 1100mm - 1200mm above floor. Recommend two spy holes with one at standing height, one sitting.
AE
Two spy holes one at standing and one at sitting height
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 14 Bedrooms (cont.)
Accessibility standards for M3i, M3a & AE
M3
Where telephone is not provided there must be an emergency alarm call system in reach from floor.
AE
Emergency alarm call system in reach from floor.
M3/ AE
Beverage facilities where available should provide a cordless kettle at table level close to an electrical socket.
M3/ AE
Emergency evacuation notice clearly positioned between 900 – 1200mm above floor level.
M3/ AE
Wardrobe door handles easy grip and involve minimal twisting 9001200mm from ground
M3/ AE
Clothes rail fittings adjustable or 2 levels or lower level max 900mm Adjustments made for individual guests. Hanger no higher than 1200mm for ambulant guests
AE
M3/ AE
Seating level mirror with bottom edge no more than 900mm above the floor (where provided)
M3/ AE
Full length mirror, at least 1800mm high with bottom edge 400mm max above floor (where provided)
Present situation
Intended action
Cost
Date
16
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 14 Bedrooms (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Recommend windows at least 800mm from floor. Ease of access to and use of windows and controls
AE
Ability to see through one window whilst sitting down. One window catch 800mm-1000mm, max reach 400mm
M3/ AE
Bathroom/ shower room general
Accessibility standards for M3i, M3a & AE
M3/ AE
En-suite bathroom must be available. (SC only–can be within 10 metres of bedroom and on same floor)
M3
Door clear opening width not less than 750mm, recommend 800mm Not less than 850mm.
AE
17
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
Phones with large buttons recommended
Standard
Section 15
Present situation
M3/ AE
If open outwards, rail on inside.
M3/ AE
Space outside, opposite door not less than 1200mm, recommend 1500mm
M3a M3i/ AE
Recommend: Door emergency release mechanism
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 15 Bathroom/ shower room general (cont.)
Accessibility standards for M3i, M3a & AE
M3
AE M3/ AE
Present situation
Intended action
Cost
Date
Unrestricted floor space 1200mm x 1200mm, recommend 1500mm x 1500mm 1500mm x 1500mm Wash basin with lever taps, not more than 1/4 turn At least 500mm wide, 430mm-510mm projection. Recommend straight front & adjustment in height
M3/ AE
Clear under-space, no pedestal, vanity unit or boxing
M3/ AE
Hot pipes etc that may come into contact with arms and legs should be well insulated/protected.
M3
A vertical rail on at least one side of the wash basin. 600mm long, midpoint 1100mm above floor.
AE
Vertical rail on both sides of wash basin. 600mm long, midpoints 1100mm above floor.
AE
Towel rail, soap dispenser 900-1200mm high, accessories and fittings between 750mm - 1200mm above floor
M3/ AE
Emergency alarm call/pull cords should be in reach of the floor and coloured red. (SC only–method of attracting attention recommended)
M3 AE
Recommend: Direction of transfer - shower, toilet, bath consistent
18
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 15 Bathroom/ shower room general (cont.)
Accessibility standards for M3i, M3a & AE
M3a/ AE
Recommend tracked hoist
M3/ AE
Swing top bin
M3/ AE
Where hairdryer provided 800mm1200mm high and near mirror
M3/ AE
Full length mirror lower edge max 400mm - min 1800mm top (where provided). Mirror above basin lower edge level with basin to min 1600mm top (where provided)
19
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 16
Accessibility standards for M3i, M3a & AE
Bath or bath with overhead shower
M3
Unobstructed space to side of bath at least 800mm wide, recommend 900mm.
Where both shower and bath are provided both must must meet the criteria.
AE
At least 900mm wide.
M3/ AE
Height from floor to rim of bath between 450mm - 500mm (unless hoist available). Lever taps or attachments max 1/4 turn.
M3a/ AE
Clear space of at least 150mm under bath
M3/ AE
Horizontal or angled support rail opposite bath transfer space between 150mm - 250mm above bath rim. At least 450mm-600mm long. Rail extends full length of bath.
M3/ AE
Slip resistant bath or bath mat. Bathing board or seat provided.
Present situation
Intended action
Cost
Date
Where a bath only is provided, there must be some means of entering and/or bathing in a sitting position at rim height AE M3/ AE
Bath stool provided A slip resistant vertical rail between 900mm - 1400mm above bath base and 450mm - 600mm long towards tap end.
20
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 17 Shower (where provided) Where both shower and bath are provided both must must meet the criteria.
Accessibility standards for M3i, M3a & AE
M3i
Where only one accessible facility it must be a shower with level entry
M3/ AE
A separate shower or shower only bathroom provided and must have a level entry
M3/ AE
A hinged shower seat at 450mm 500mm above shower base (or shower wheelchair), transfer space 800mm wide, recommend 900mm Transfer space 900mm
AE M3i/ AE AE
Shower stool available.
M3/ AE
Surface of seat at least 400 x 400mm
M3/ AE
Centreline of shower seat not more than 500mm from wall opposite transfer space.
M3/ AE
Horizontal support rail opposite transfer space at least 450mm long and between 200mm-300mm above seat.
AE
21
If a shower wheelchair is used it must be self propelled
Vertical rail by shower 800mm1400mm above base
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 17 Shower (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
A hinged rail on the transfer side of the seat between 350mm-400mm from centreline of seat and 200mm - 300mm above seat (unless shower wheelchair provided)
M3/ AE
Controls and detachable shower head adjustment height between 900mm-1200mm used in standing and sitting position.
Present situation
Intended action
Cost
Date
Consider two showerheads – one sitting and one standing. M3 AE
Recommend lever or button controls Lever or button controls
M3/ AE
Towel rail 900mm -1200mm above floor. Prefer in reach from showerseat
M3/ AE
Thermostatic mixer or limiter with o water temperature control to 41 C
M3/ AE
Emergency alarm call system provided. Pull cords should be in reach of the floor and coloured red.
M3a/ AE
Recommend tracked hoist
M3/ AE
Shelf/soap dish provided in reach whilst sitting
22
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
23
Standard
Section 18 WC
Accessibility standards for M3i, M3a & AE
M3/ AE
Shelf or level surface in reach from WC
M3
Clear transfer space to side of WC at least 800mm, recommend 900mm
AE
At least 900mm wide
M3
Recommend front edge of WC rim to project at least 750mm
AE
Front edge of WC rim to project 750mm
M3/ AE
Centreline of WC not more than 500mm from wall opposite. Support rail 350mm - 400mm of centreline
M3/ AE
WC seat height between 450 500mm above floor, with or without raiser
M3/ AE
A seat height adjuster available on request.
M3/ AE
Flushing handle on most accessible side of cistern, recommend spatular shaped.
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 18 WC (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Vertical rail to side of WC 600mm long and top 1400mm max. If a hinged rail it must lock.
M3/ AE
Horizontal support rail fixed to wall opposite transfer space. 450mm 600mm long, 200mm - 300mm above seat 600mm long
AE M3/ AE
A hinged rail on transfer side between 350mm - 400mm from centreline of WC and between 200mm - 300mm above WC seat. Must lock.
M3/ AE
Toilet paper holder within easy reach. Recommended usable with one hand.
M3/ AE
Swing top bin and/or swing top sanitary bin provided.
M3/ AE
Recommend wash basin in reach whilst on WC.
Present situation
Intended action
Cost
Date
24
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 19 Kitchen area (where provided)
Accessibility standards for M3i, M3a & AE
M3/ AE
Minimum clear floor space 1200mm in front of units and work surfaces.
M3i/ AE
At least one work surface or table must have a clear under space between 650 high and 800 wide. Max work surface height 850mm. Preferred.
M3a
25
M3/ AE
The hob should be no more than 850mm high and have a clear under space or space along side, and accessible controls.
M3a
Maybe a portable hob.
M3/ AE
The oven should have front controls no higher than 1150mm and a base between 650mm - 800mm above floor. Alternatively a combined microwave oven no more than 850mm high. Work surface close for hot dishes.
M3 AE
Recommend: o Doors swing 180 .
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 19 Kitchen area (where provided) (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Sink with lever taps or attachments
M3i/ AE
Clear space under sink of 650mm 750mm. Underside of sink to be insulated. Recommend sink height 800mm900mm and 150mm deep Preferable
M3a
M3/ AE
The base of wall cupboards and shelves should be no more than 1200mm above floor. Preferable, but with adequate provision of storage Crockery and utensils placed at desired height on arrival
AE
Perching stool must be provided
M3i/ AE M3a
M3/ AE
Light switches, door handles, power sockets height 900mm – 1200mm
M3i/ AE M3a
Powersockets not more than 1200mm, recommend 900-1200mm Preferable
M3/ AE
Fire extinguisher/fire blanket between 900mm - 1200mm above floor and between cooker hob and doorway and easily accessible
Present situation
Intended action
Cost
Date
26
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 19 Kitchen area (where provided) (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
At least one shelf of fridge and freezer 600mm - 1200mm
M3/ AE
Where provided, electric kettles must be cordless
M3i/ AE
Controls for general appliances no higher 1200mm or 1150mm across work surface.
M3a
Preferable
Standard
Section 20 Public area WC
27
Accessibility standards for M3i, M3a & AE
M3
Door with opening at least 750mm, recommend 800mm. Outside opposite door 1200mm.
AE
At least 850mm clear opening. Outside opposite door 1200mm.
M3
Recommend emergency door release and rail on outside/inside door depending on direction of opening.
AE
Emergency door release and rail on outside/inside door.
Present situation
Intended action
Cost
Date
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 20 Public area WC (cont.)
Accessibility standards for M3i, M3a & AE
M3i
Present situation
Intended action
Cost
Date
Unobstructed floor space clear of any door swing 1200mm x 1200mm
M3a/ AE
1500 x 1500mm
M3/ AE
Wash basin with lever taps, with no more than 1/4 turn and clear under space. Recommend basin in reach whilst on WC. Hot pipes insulated. Recommend straight edge and adjustable height.
M3
Vertical support rail 600mm long on at least one side of basin 1100mm above floor.
AE
Vertical rail each side of basin.
M3/ AE
Towel rail/hand drier 900mm 1200mm above floor. In reach of basin. Use single handed.
M3
Clear transfer space to side of WC at least 800mm wide, recommend 900mm.
AE
At least 900mm
M3i
Recommend front edge of WC rim to project at least 750mm from back wall.
28
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 20 Public area WC (cont.)
Accessibility standards for M3i, M3a & AE
M3a/ AE
Front edge of WC rim to project at least 750mm from back wall.
M3/ AE
Centreline of WC not more than 500mm from wall opposite transfer space. Support rails 350mm-400mm of centreline
M3/ AE
WC seat height between 450mm 500mm with/out raiser. Seat height raiser to be available on request
29
M3/ AE
Flushing lever to be on most acceptable side of cistern. Recommend spatula shaped handle
M3/ AE
Shelf or level surface provided in reach from WC
M3/ AE
Vending machines accessible and not obstructing routes/transfer
M3/ AE
Seat to be a continuous ring. Toilet seat to have no lid.
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 20 Public area WC (cont.)
Accessibility standards for M3i, M3a & AE
M3/ AE
Swing top bin and/or swing top sanitary disposal
M3/ AE
Clothes hooks 1050mm and 1400mm
M3/ AE
Mirrors – lower edge no higher than basin – min 1600mm top. Full length max 600mm bottom – min 1600mm top
M3/ AE
Horizontal support rail opposite transfer space at least 450mm long (600mm recommended) 200mm 300mm above seat level.
M3/ AE
Vertical rail beside WC 600mm long, top no higher than 1400mm. If hinged, it must lock.
M3/ AE
Hinged rail on transfer side 350 – 400mm from centre line of WC and 200 – 300mm above seat level. This must be lockable.
M3/ AE
Toilet paper holder within easy reach of WC and recommend able to use with one hand.
M3/ AE
Emergency cord within reach of floor. Emergency release mechanism on door.
Present situation
Intended action
Cost
Date
30
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
31
Standard
Section 21 Public areas eg. bar, lounge
Accessibility standards for M3i, M3a & AE
M3/ AE
Stable table, preferably without central column, 650mm - 750mm space under/ 1 per accessible bedroom. Blocks to raise are acceptable.
M3/ AE
Selection of chairs with and without armrests. At least one with arms. Chair in close proximity to bar.
M3/ AE
Staff available to assist guests
M3
Recommend:
AE
Lower section of bar and serveries.
M3/ AE
Where TV’s provided - they must have remote control
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
Standard
Section 22 Public telephones (where provided)
Accessibility standards for M3i, M3a & AE
M3/ AE
Unobstructed route free from obstacles and area suitable for wheelchair turning.
M3/ AE
Guests to be able to hold a private conversation and telephones accessible height.
M3/ AE
Accessible phones clearly indicated.
M3/ AE
Controls, coin/card slots - 7501000mm high with clear underspace 500mm, phone to be angled for use for use whilst seated.
M3
Recommended length of cord from phone to handset 750mm long.
AE
Length of cord 750mm long.
M3/ AE
Present situation
Intended action
Cost
Date
Where acoustic hoods fitted, must not be hazard, at a suitable height for use seated and preferably have hazard warning of protrusion.
32
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus
National Accessible Scheme Self Survey Mobility M3 Independent (M3i), M3 Assisted (M3a) and Access Exceptional (AE)
VB 0 70958 130 0 01/05
33
Standard
Section 23 Conference/ banqueting/ entertainment
Accessibility standards for M3i, M3a & AE
M3/ AE
Where a lecturn is provided it should be height adjustable.
M3/ AE
Accessible WC located close & recommend on same floor.
M3/ AE
Where a raised staged area is used there must be wheelchair access.
M3/ AE
Switches and lights for equipment 900-1200mm.
M3
Where tiered lecture/ entertainment rooms exist, there must be at least access to one level with good views for wheelchair access. Suggest movable seating.
AE
Seating provided for ambulant people on crutches - aisle between seating rows 1200mm.
Present situation
Intended action
Cost
Date
National Accessible Scheme Self Survey for Serviced, Self-Catering, Hostel and Campus Accommodation
• M3 for independent wheelchair users (M3i) • M3 for assisted wheelchair users (M3a) • Access Exceptional (AE) Use: To assess the suitability of your premises for participation in the VisitBritain National Accessible Scheme. How to use: Carry out an audit of your premises and complete all areas of the form to give the current accessibility of your premises in the ‘Present Situation’ column. This will give you an idea of any work that needs to be completed to reach the level of accessibility you wish to achieve for your target market. If your property does not meet the criteria, please use the ‘Intended Action‘ column to highlight reasons for the deficiencies and the next course of action. Once quotes/cost estimates have been obtained for the work, please fill in the cost. Use the date column to highlight potential completion dates and/or quote dates. These forms should be kept in an accessibility file together with any relevant documentation such as quotes in order to help meet the requirements of the Disability Discrimination Act (DDA 1995). We recommend that these forms should become a working document to be regularly updated and reviewed.
VB 0 70958 130 0 01/05