ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project
MMAH
ASCOTEC
DOCUMENT TITLE
:Document No
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
:Designer Document NO
.Rev
MISP1301ETS113
1-1
MWES1U43E00113 0011
:Project Document NO
DATE: Nov. 2009 Page: 1 of 6
DOCUMENT TYPE : DATA SHEET DOCUMENT TITLE :
DATA SHEET for LIGHTING EQUIPMENT
1
Nov. 09
N.Alizadeh
M.Khosravian
A.Hemmatian
Issued For Review
Prepared Checked Approved Client Purpose of Issue CONTRACTOR This document and the information disclosed are the property of MMTE and are not to be used to furnish any information for making of documents or apparatus except where approved by written agreement. Rev.
DATE
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE
ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project ASCOTEC
DOCUMENT TITLE
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
MMAH :Document No
:Designer Document NO :Project Document NO
.Rev
MISP1301ETS113 MWES1U43E00113 0011
1-1
DATE: Nov. 2009 Page: 2 of 6
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
REVISION RECORD SHEET
Note: This Table is used for External Comments
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE
ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project ASCOTEC
DOCUMENT TITLE
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
MMAH :Document No
:Designer Document NO :Project Document NO
.Rev
MISP1301ETS113
1-1
MWES1U43E00113 0011
Description
DATE: Nov. 2009 Page: 3 of 6
Type
Qty
Total
LIGHTING SYSTEM : Street light High pressure Sodium lamp 250 W , 230 V , 26000 Lm
250w
Flood light High pressure Sodium lamp 400 W , 230 V , 48000 Lm
400w
Tunnel type DC emergency light
outdoor
110VDC , 110W lamp Lighting pole Street lighting pole , hot dip galvanized , tilt of 25º degree,height=12m Lighting pole accessories Fuse Fuse Base terminal fastener
10A for 16mm² cable for 4x 16mm² cable
PVC Conduit( φ=30 mm ) m Fastener Fastener's belt( φ=32-51 mm )
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE
ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project
MMAH
ASCOTEC
DOCUMENT TITLE
:Document No
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
:Designer Document NO :Project Document NO
.Rev
MISP1301ETS113
DATE: Nov. 2009
1-1
MWES1U43E00113 0011
Page: 4 of 6
OUTDOOR LIGHTING SYSTEM ITEM
DESCRIPTION
1
manufacture catalogue and designation of the main lighting equipment
2
:min. in service horizontal illumination level
UNIT
2.1
switchyard
lux
2.2
access roads
lux
2.3
fence
lux
2.4
outside of fence
lux
2.5
vertical surface of main equipments
lux
2.6
main entrance
lux
3
SUPPLIER’S DATA
lighting factors taken into consideration
3.1
uniformity factor
3.2
utilization factory
3.3
maintenance factor
4
:switchyard lighting
4.1
type of fixture
4.2
fixture mounting height
m
4.3
ballast mounting height
m
4.4
type of lamp
w
4.5
lamp life
h
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE
ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project
MMAH
ASCOTEC
DOCUMENT TITLE
:Document No
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
:Designer Document NO
.Rev
MISP1301ETS113
1-1
MWES1U43E00113 0011
:Project Document NO
DATE: Nov. 2009 Page: 5 of 6
OUTDOOR LIGHTING SYSTEM ITEM
DESCRIPTION
4.6
lamp efficiency
4.7
power factor
4.8
number of fixtures
5
UNIT
access and main road lighting
5.1
type of fixture
m
5.2
fixture mounting height
w
5.3
type of lamp
5.4
lamp efficiency
5.5
power factor
5.6
number of fixtures
6
fence lighting
6.1
type of fixture
6.2
fixture mounting height
6.3
power factor
6.4
pole spacing
6.5
pole distance from fence
6.6
number of fixtures
7
SUPPLIER’S DATA
m
m
complementally lighting near transformers and reactors
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE
ELCO STEEL MMTE MME MIYANEH COMPLEX Steel Making Plant Project
MMAH
ASCOTEC
DOCUMENT TITLE
:Document No
C:\Documents and Settings\All Users\Documents\sub-2-9-88\88.8.30\LI data sheet\Rev.1-2\LI Rev.1-2.doc
NISCO 230/33 KV SUBSTATION DATA SHEET FOR LIGHTING EQUIPMENT
:Designer Document NO
.Rev
MISP1301ETS113
1-1
MWES1U43E00113 0011
:Project Document NO
DATE: Nov. 2009 Page: 6 of 6
OUTDOOR LIGHTING SYSTEM ITEM
DESCRIPTION
UNIT
7.1
type of fixture
7.2
fixture mounting height
m
7.3
type of lamp
w
7.4
number of fixtures
8
:110V DC emergency lighting
8.1
type of lighting fixture
8.2
type of fitting
8.3
type of lamp
8.4
locations mounted
8.5
number of lighting fixture
9
SUPPLIER’S DATA
total lighting load
10
type of photo - cell relay
11
type and detail of lighting poles
12
emergency lead lighting
w
kw
Confidential: This document discloses proprietary information. It may not be reproduced nor disclosed any person, nor used for any purpose, except with the written .permission of MMTE