Hico Induction Motor Data Sheet

  • December 2019
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Hico Induction Motor Data Sheet as PDF for free.

More details

  • Words: 364
  • Pages: 1
INDUCTION MOTOR DATA SHEET SHEET FOR APPROVAL SERVICE :

OF

FRAME NO. TYPE ENCLOSURE * COOLING METHOD ** FREQUENCY PHASE INSULATION CLASS TEMP. RISE AT FULL LOAD RES. METHOD THERMO. METHOD LOCATION ALTITUDE HUMIDITY AMBIENT TEMP.(MAX. ), ¡É RATING NEMA DESIGN MOUNTING BEARING TYPE UNLOAD / LOAD BRG. NO. BRG. LUBRICATION PROTECTION GRADE SERVICE FACTOR DRIVE SHAFT EXTENSION VERTICAL EXTERNAL THRUST

CUSTOMER JOB NO. SITE

: : :

GENERAL DATA 215T TEFC TE FC 60 Hz 3 PHASE F 80

OUTPUT POLES ROTOR TYPE STARTING METHOD

INDOOR 1000 m 80 % MIN -15 / MAX : 40 CONTINUOUS B HORIZONTAL ANTI-FRICTION 6206ZZ / 6208ZZ GREASE IP44 1.15

MAX. LOAD WK2 AT MOTOR SHAFT (At Direct On Line)

ACCESSORIES (OPTIONAL) TEMPERATURE DETECTOR WINDING NO TYPE BEARING NO TYPE SPACE HEATER NO RATING PH V SLIDE BASE SOLE PLATES TERMINAL BOX MAIN AUX. APPLICATION STANDARDS

575 3.1 9.7 64.8

SETS HP

V A A A V A ¥Ø

91.0

% % %

87.0 3500

% % % RPM

15.0 33.0 37.5

lb¤ýft lb¤ýft lb¤ýft

34.700

lb¤ýft2 lb

MOTOR APPROX. WEIGHT 155 PAINTING (MUNSELL NO.) 7.5 BG 5/2 SUBMITTAL DRAWINGS OUTLINE DIMENSION SMK0061H06 SME2417H03 CONDUIT BOX & COVER CHARACTERISTIC CURVE W

DP : DRIP PROOF * EP : EXPLOSION PROOF TE: TOTALLY ENCLOSED WPII : WEATHER PROTECTED II TC : TUBE COOLED ** SC : SELF COOLED FC : FAN COOLED WC : WATER COOLED ***SHOULD CHECK ATTACHED DATA SHEET ¾ç½Ä TE-25-0102-2A4

NT111B

ITEM NO. : QUANTITY : PERFORMANCE DATA 7.5 KW 10 2 Poles SQUIRREL CAGE DOL

PRIMARY VOLTAGE NO LOAD CURRENT FULL LOAD CURRENT STARTING CURRENT SECONDARY VOLT(OPEN CIRCUIT) CURRENT(LOAD) RES.(AT 25¡É LINE) EFFICIENCY AT 1 / 2 LOAD AT 3 / 4 LOAD AT FULL LOAD POWER FACTOR AT 1 / 2 LOAD AT 3 / 4 LOAD AT FULL LOAD SPEED (AT FULL LOAD) TORQUE FULL LOAD LOCKED ROTOR BREAK DOWN

¡É

HYOSUNG SHOP ORDER NO.

EXCEPT FOR STATEMENTS SPECIFIED ON THIS SHEET, ANYTHING ELSE SHALL BE IN ACCORDANCE WITH HYOSUNG STANDARD. 1. Above data are nominal values which have the tolerance in accordanve with IEC34-1 or NEMA MG1.

DATE

PREPD BY

CHKD BY

APPRVD BY

00-06-05

K.S.LEE

P.S.PARK

M.C.HAN A4(210x297)