2
3
10.00
4.00
3.00
1
4
1.50
3.00
4.00
3
10.00
4
3.00
0.80 1.20
W4
1.00
W1
A
C10
2.00
C7
RECOMMENDING APPROVAL:
C11
Fire Exit
3.50
3.50
W4 W1 W4
W3 C6
B
C
3.00
BUILDING OFFICIAL
10.00
3.00
B
10.00
REPUBLIC OF THE PHILIPPINES DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE BUILDING OFFICIAL MUNICIPALITY OF SOGOD PROVINCE OF SOUTHERN LEYTE
3.00
1.50
W4
A
2
0.85 0.94
1
DATE
W2
C
3.50
3.50
storage
C8
W1
GROUND FLOOR C9 D
c
SECOND FLOOR
POWER LAYOUT SCALE
FG
1
:
100
M
D1
D
GB
c
ELEV. +00
TERRACE
SCHEDULE SWITCH
CIRCUIT NO.
LOAD DESCRIPTION
1 2 3 4 5 6 7 8 9 10 11 12
LIGHTING OUTLET LIGHTING OUTLET LIGHTING OUTLET LIGHTING OUTLET LIGHTING OUTLET ACU OUTLET ACU OUTLET CONVENIENCE OUTLET CONVENIENCE OUTLET CONVENIENCE OUTLET ACU OUTLET SPARE
S1 1 3 3 3 3
S2
S3 2 2 2 2 1
OF
POWER LAYOUT
TERRACE
SCALE
1
:
100
M
LOADS
POWER / WATTAGE
VOLTAGE
CURRENT
106W 106W 97W 97W 97W 3200VA 3200VA 1200VA 1600VA 1200VA 3200VA
220V 220V 220V 220V 220V 220V 220V 220V 220V 220V 220V 220V
0.4818A 0.4818A 0.4409A 0.4409A 0.4409A 14.5454A 14.5454A 5.4545A 7.2727A 5.4545A 14.5454A
CIRCUIT PROTECTION 15 AT,2P 15 AT,2P 15 AT,2P 15 AT,2P 15 AT,2P 20 AT,2P 20 AT,2P 20 AT,2P 20 AT,2P 20 AT,2P 20 AT,2P 20 AT,2P
CONDUCTOR SIZE
CONDUIT SIZE
3.5mm 3.5mm 3.5mm 3.5mm 3.5mm 5.5mm 5.5mm 5.5mm 5.5mm 5.5mm 5.5mm 5.5mm
ELECTRICAL SPECIFICATIONS 220V, 60 Hz
1. ALL ELECTRICAL WORKS AND INSTALLATION THERE IN SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST APPROVED EDITION OF THE PHILIPPINE ELECTRICAL CODE WITH THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELECTRICAL LAWS AND ORDINANCES AND WITH THE POLICIES OF THE LOCAL UTILITY COMPANY CONCERNED. 2. NO WIRE SMALLER THAN No. 3.5 mm2 AWG TWG SHAAL BE USED. 3. ALL MATERIALS USED SHALL BE NEW AND OF APPROVED TYPE FOR BOTH LOCATION AND PURPOSES INTENDED. 4. ALL OUTDOOR INSTALLATION SHALL BE OF WEATHER PROOF TYPE. 5. ALL ELECTRICAL WORKS AND INSTALLATIONS HERE IN SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN.
2-38.0mm
M 100 AT 2-3.5mm
2-3.5mm
15 AT 2
2-3.5mm
2-3.5mm
2-3.5mm
2-5.5mm
2-3.5mm
2-5.5mm
2-5.5mm
2-5.5mm
2-5.5mm
2-5.5mm
2-5.5mm
15 AT 4
10
C:\Users\user\Documents\calimbas plan\logo copy.bmp
NO PORTION OF THIS SET OF PLAN SHOULD BE COPIED EITHER MANUALY OR ELECTRONICALLY WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
7 20 AT
20 AT
FROM THE OFFICE OF:
5 20 AT
20 AT
SPARE
3 15 AT
20 AT 8
1 15 AT
20 AT 6
Computation for the total current:
15 AT 2-3.5mm
9 20 AT
SEAL
11
It = [total connected load + 25% of the largest motor] 220 V It =14,103 W + (0.25)(3200W) It = 67.74 amperes Ita = (67.74 A) ( .90 ) Ita =60.96 amperes Note: Assume 90% demand factor for commercial building Therefore: Use 100 AT, 2P circuit breaker for main protection.
NAME OF PROJECT:
APPROVED AS PER PLAN:
SLSU ALUMNI OWNER
ELECTRICAL ENGINEER PRC No.: PTR No.
Date Reg.
T I N No.
Date:
Place:
LOCATION: BRGY. SAN ROQUE,SOGOD, SOUTHERN LEYTE
LOCATION: BRGY. SAN ROQUE,SOGOD, SOUTHERN LEYTE
SHEET CONTENTS:
SHEET NUMBER