Cyberknife Radiosurgery A new treatment method for image guided robotic high precision radiosurgery

High precision radiosurgery

Cyberknife radiosurgery – Overview Cyberknife technology is based on radiosurgical principles which are in clinical practice since 30 years. Radiosurgery is the precise application of a high (tumor destructing) dose of radiation in a precisely defined target volume protecting the surrounding healthy tissue. During radiosurgery many radiation beams from different directions intersect in the tumor region where they accumulate to a total dose. Surrounding healthy tissue only receives a small fragment of the total dose. Until recently the Gamma Knife system was the standard instrument for neurosurgical applications. Some centers use linear accelerators (LINAC) for clinical radiosurgical procedures. These mostly in conventional radiation oncology used systems have to be readjusted for every radiosurgical treatment and must undergo physical testing because radiosurgical applications demand significantly higher quality and precision requirements as for conventional radiooncological indications. However, Gamma Knife and conventional LINACs share the same necessitiy to apply an invasive stereotactic ring on the patients head to achieved the desired accuracy of +/- 1 mm. The revolutionary development of the Cyberknife technology combining integrated image guided and robotic

technology lead to a paradigm shift in radiosurgery (1).

Advantages of Cyberknife radiosurgery With Cyberknife technology an invasive stereotactic head frame is no longer required to obtain highest possible accuracy for brain treatments. This offers to the patient for the first time a real non-invasive and pain free radiosurgical treatment. Moreover, if feasible, the treatment can be dived in several stages (2 – 5) which makes it even safer to treat lesions in highly sen-

sitive areas or larger lesions (2,3,4,5). Apart from standard neurosurgical indications (i.e. acoustic neurinomas, meningeomas, brain metastases) radiosurgical applications are currently evolving to extracranial indications (Fig. 1). It is nowadays possible to treat tumors of the spine, the pancreas, the lung and the liver safe and effectively with radiosurgical techniques in case they are well delineated from the surrounding healthy tissue. In selected cases this could replace a surgical procedure. Because of the physiologic breath dependent

Fig. 1: Example of CT based computer planning using the Cyberknife software in a patient with a small tumor in the region of the inner ear. The radiation dose is displayed in axial, sagittal and coronal direction. The tumor was treated with a maximum dose of 25 Gy

High precision radiosurgery organ movement it was up to now not possible to apply high radiation doses to body lesions. The newest development in Cyberknife radiosurgery is a breath triggered real time movement correction which makes it possible to apply radiosurgical doses to body lesions (6,7). The Cyberknife is moving according to the tumor movement: infrared cameras follow the breath excursions and send this information online to the robot which steers the LINAC in the correct position. Anaesthesia or dedicated body stereotactic frames as used with conventional radiation devices to suppress respiration are no longer affordable. Cyberknife treatment is designed for outpatient treatment which significantly enhances the quality of life of cancer patients. A hospital stay or rehabilitation is not needed in most cases. Treatment time is dependent on tumor location, tumor size and organs at risk. A full course of radiosurgery lasts between 60 and 90 minutes.

movements in a range of 10 millimetres. A dedicated algorithm is compensating for the inherent system latency. For cerebral and spine indications a co-registration of the aquired x-ray images of the bony structures with the digital reconstructed images of the planning CT (DRRs = digital reconstructed radiographs) is performed. DRRs are continousely matched with the x-ray images during treatment.

65 Frameless stereotaxy – accuracy Academic studies at the University Stanford and Los Angeles, USA and San Bertolo hospital in Vicenza, Italy showed that frameless Cyberknife technology is as precise as the conventional frame based systems (8). Phantom studies achieved all over accuracies (including imaging, planning, treatment) of 0.42 ± 0.4 mm (Fig. 4).

Treatment schedule Dynamic patient correction Moving target volumes can be monitored and irradiation dynamically adapts to the movement, accordingly (6,10). After percuta-

For brain treatments an individual head mask is done. This helps to stabilize the head of the patient during treatment. For lesions in moving organs like lung, liver or

Technology The Cyberknife technology is a composition of two main parts: The radiation source which is a light weight and compact photon device (6 MeV LINAC, dose rate 4 Gy/minute) coupled to a robotic arm capable of moving in 6 degrees of freedom (Kuka GmbH, Augsburg, Germany) (Fig. 2). The robot can approach 1200 positions during treatment. The robot is linked to a computerized localization system consisting of two x-ray generators which are fixed on the ceiling to enable orthogonal images of the target region. Images are recorded on silicon detectors which generate high resolution digital images. According to the location of the target region exact patient positioning is automatically done by a 5 axis patient couch. During treatment the system automatically corrects eventual patient

Fig. 2: Figure 2 shows the Cyberknife system with major components such as the treatment couch, the x-ray detectors (silicon detectors), x-ray cameras at the ceiling, robot and compact LINAC

nously applied fiducial makers the internal organ movement is defind by the x-ray image guided sytem. Parallel to that external light emitting diodes (LEDs) which are fixed on the breast of the patient measure the breath excursions (Fig.3). The software is calculating the organ movement taking into account the internal and external target volume. Systemically performed x-ray image updates are the basis for iterative corrections of the correlation model.

pancreas small (5 mm) metal markers are percutaneusely implanted in the vicinity of the lesion (Fig. 5). They are used as landmarks for image registration and are automatically detected by the x-ray camera system. Image registration for brain treatments is performed without external fidicials; image registration is performed using bony scull structures (Fig. 6). All treatments are performed on the basis of CT and MRI imaging. The frameless technology allows

High precision radiosurgery

66

with the University Hospital of the University Munich. Principally, well circumscribed tumors with a clear border to the surrounding healthy tissue are suitable for Cyberknife radiosurgery. Currently, main indications are tumors of the brain and spine. The efficacy of Cyberknife radiosurgery for body lesions is presently being evaluated.

Future perspectives New research activities are focussing on the full potential of robotic techniques for radiosurgical applications. One of the primary goals is the introduction of real time image guidance of tumors in soft tissue without the implantation of fiducials. This would require a fast fully automated analysis of x-ray imaging during treatment. This technology is currently undergoing phantom tests (10,11). Furthermore, research activities are done to optimize the inverse planning algorithm and to take into account the relative organ movement during respiration. Fig. 3: Schematic drawing of breath triggered body irradiation. The signals of the LEDs are recorded by the infrared cameras and are used together with the information of the x-ray images for the robot to move according to the tumor position during treatment

to perform planning images days before radiation application. Dose planning is performed using an inverse dose planning algorithm where the dose prescription to the target volume is defined by the tolerance dose to the organs at risk (9). During treatment the patient is awake and monitored by a video camera system. During treatment the robot is moving to 100 defined virtual points in space which are distributed homogeneously above the target. From each of these points the robot can be directed to each direction inside the treatment volume (non-isocentric radiation). Complex optimization techniques weight the individual beam in such a way that a high dose of radiation is directed to the tumor taking into account the specific limitations of the organs at risk. The stereo x-ray system is constantly recording images during

treatment and compares these with the generated DRRs of the planning CT providing the highest possible precision during treatment.

Medical indications The European Cyberknife Center Munich is a cooperative institution

Literatur 1. Adler, John R. Jr., Martin J. Murphy, Steven D. Chang, and Steven L. Hancock. 1999. Imageguided robotic radiosurgery. Neurosurgery 44 (6): 1299-1307. 2. Chang, Steven D., David P. Martin, and John R. Adler. 1998. Treatment of spinal AVMs and vas-

Fig. 4: Example of a Cyberknife accuracy check. Two film projections in 90° angle to each other are displayed. It was aimed to center the irradiation (blue area) on the tip of the white groove

High precision radiosurgery

67

cular tumors with frameless imagedbased radiosurgery. Journal of Neurosurgery 88 (1):201A.

Radiosurgery. Computer Aided Surgery (5):263-277.

3. Chang, Steven D., Martin J. Murphy, James R. Doty, Steven L. Hancock, and John R. Adler. 1999. Image-guided robotic radiosurgery: Clinical and radiographic results with the CyberKnife. In Radiosurgery, ed. D. Kondziolka. New York: Karger Medical and Scientific Publishers.

7. Murphy, Martin J., John R. Adler, Jr., Mohan Bodduluri, John Dooley, Kenneth Forster, Jenny Hai, Quynh Le, Gary Luxton, David Martin and Joseph Poen. 2000. ImageFig. 5: Display of metal markers used as landmarks for patient positioning for body treatments Guided Radiosurgery for the Spine and Pan11. Schweikard, A., Shiomi, H., creas. Computer Aided Surgery Adler, J. 2005. Respiration (5):278-288. Tracking in Radiosurgery without Fiducials International Journal of Medical Robotics and Computer Assisted Surgery (1), 19-27, Robotic Publications Ltd. (www.roboticpublications.com), Ilkley, UK.

4. Chang, Steven D., Martin J. Murphy, Paul Geis, David P. Martin, Steven L. Hancock, James R.

Contact:

Dr. med. A. Muacevic

Fig. 6 : Showing the principle of generating DRRs (digital reconstructed radiographs). Based on CT imaging lateral scull x-ray images are reconstructed which are used for patient image registration

Doty, and John R. Adler. 1998. Clinical experience with image-guided robotic radiosurgery (the CyberKnife) in the treatment of brain and spinal cord tumors. Neurologia MedicoChirugica 38 (11):780-783.

8. Murphy, Martin J., and Richard Cox. 1996. The accuracy of dose localization for an image-guided frameless radiosurgery system. Medical Physics 23 (12): 2043-2049.

5. Chang, Steven D., Martin J. Murphy, James R. Doty, and John R. Adler, Jr. 1999. Stereotactic Radiosurgery: New Innovations. Perspectives in Neurological Surgery 10 (1):151-159.

9. Schweikard, A., Bodduluri, M., Adler, J.R. 1998. Planning for Camera-Guided Radiosurgery IEEE. Transactions on Robotics and Automation 13, 951-962.

6. Schweikard, Achim, Greg Glosser, Mohan Bodduluri, Martin J. Murphy and John R. Adler, Jr. 2000. Robotic Motion Compensation for Respiratory Movement During

10. Schweikard, A., Shiomi, H., Adler, J. 2004. Respiration Tracking in Radiosurgery Medical Physics, American Association of Physicists in Medicine (31), 2738-2741.

PD Dr. B. Wowra

Prof Dr. Ing A. Schweikard Director Institute of robotic and kognitive systems University Lübeck Germany

European Cyberknife Center Munich Max-Lebsche-Platz 31 D-81377 Munich/Germany Phone: +49-89-4523360 Fax: +49-89-45233616 Mail: [email protected] Web: www.cyber-knife.net

Related Documents

Cyber Knife
December 2019 8
Knife
June 2020 7
Knife Edge
May 2020 17
Cyber
July 2020 34
Cyber
May 2020 41
Knife Letter Final
May 2020 3

More Documents from ""

Cyber Knife
December 2019 8
Plans.pdf
November 2019 75
Tapas.docx
April 2020 45
Actividadnro01.xlsx
April 2020 59
Plans.pdf
November 2019 84