ANDAYA, BEVERLY G. BSAR 3A

21 APR 2018 AR. JOSE MARI DE LEON

COMPARATIVE ANALYSIS PD 1096 (NATIONAL BUILDING CODE)

BP 344 (ACCESSIBILITY LAW)

RA 9514 (FIRE CODE)

2.00 m 900 mm 1200 mm

2.00 m 800 mm

2.00 m 710 mm 1220 mm

DOORS Minimum height Minimum width Maximum width Height of door knob LOCATION ON PROPERTY Front setback Side setback Rear setback Distance of eaves from property line MINIMUM ROOM SIZES Rooms for human habitation Kitchen Bathroom MINIMUM AIR SPACE REQUIREMENTS Schools Offices and factories Habitable rooms MINIMUM CEILING HEIGHTS Ground floor Second floor Succeeding floors Mezzanine LIGHT AND VENTILATION Windows for rooms Windows for bathrooms Minimum dimension of court Min. width of court passageway STAIRS Riser

820-1060mm (900 mm preferred) R1: 4.50 m R1: 2.00 m R1: 2.00 m 0.75 m 6.00 sqm (minimum dimension of 2m) 3.00 sqm (minimum dimension of 1.50 m) 1.20 sqm (minimum dimension of 0.90 m)

3.00 cubic meters (Allot 1.00 sqm per person) 12.00 cubic meters 14.00 cubic meters Naturally ventilated: 2.70 m Artificially ventilated : 2.70 m Naturally ventilated: 2.70 m Artificially ventilated : 2.40 m Naturally ventilated: 2.70 m Artificially ventilated : 2.10 m 1.80 m

2.00 m for walkways

2.00 m for means of egress

10% of floor area, but 1.00 sqm minimum 5% of floor area, but 2.40 sqm minimum 2.00 m 1.20 m

Thread

250 mm minimum

Minimum width

Less than 10 OL: 0.75 m 10-50 OL: 0.90 m More than 50 OL: 1.10 m

Minimum headroom Maximum vertical distance between landings Handrail height RAMPS Maximum slope Maximum cross slope Minimum width Minimum landing length Distance between landings

2.00 m 3.60 m

Existing stairs: 205mm maximum New stairs: 100-180mm Existing stairs: 230 mm minimum New stairs: 280 mm min Existing stairs: 915 mm New stairs, 0-49 OL: 915 mm New stairs, 50-1999 OL: 1120 mm New stairs, 2000 or more OL: 1420 mm 2.00 m 3.66 m

800-900 mm

760-865 mm

Handrail height

200 mm maximum

Slanted nosing preferred over protruding nosing, provide 300 mm-wide tactile strip at top and bottom of stairs.

1 in 12 No general requirements provided, only for ramps located in reviewing stands, grandstands and bleachers.

1.20 m 1.50 m 6.00 m (horizontal distance between landings) 700 mm and 900 mm

1 in 12 1 in 48 1120 mm 760 mm (vertical distance between landings) 760-865 mm