Climate.pdf

  • Uploaded by: Anandita
  • 0
  • 0
  • April 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Climate.pdf as PDF for free.

More details

  • Words: 438
  • Pages: 4
INTERGRATED DESIGN - SCHEMATICS

SHIV NADAR SCHOOL | GURGAON, HARYANA

CLIMATIC ANALYSIS

CASE STUDY

01

BEST STRATEGIES FOR DELHI

SOURCE- CLIMATE CONSULTANT 6.0 (BUILD 13) WITH ISHRAE EPW FILE OF SAFDARJUNG, NEW DELHI, INDIA

Third Year | Section C | SPA Delhi

Illustrated by Souparna Chanak

Ayushi Prerna Souparna Varad

INTERGRATED DESIGN - SCHEMATICS

SHIV NADAR SCHOOL | GURGAON, HARYANA

CLIMATIC ANALYSIS

CASE STUDY

01

STRATEGIES THE SCHOOL USES INFERENCE: The bottom 2 strategies are not energy efficient at all. But the school uses 82.8% of comfot techniques by those strategies. And as the school is in function for only the daytime. the percentage can be even more. SOURCE- CLIMATE CONSULTANT 6.0 (BUILD 13) WITH ISHRAE EPW FILE OF SAFDARJUNG, NEW DELHI, INDIA

Third Year | Section C | SPA Delhi

Illustrated by Souparna Chanak

Ayushi Prerna Souparna Varad

INTERGRATED DESIGN - SCHEMATICS

SHIV NADAR SCHOOL | GURGAON, HARYANA

CLIMATIC ANALYSIS

CASE STUDY

01

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

3 2

PRODUCED BY AN AUTODESK STUDENT VERSION

4

ANNUAL DIRECT SUNLIGHT SHADING PERCENTAGE

1 PRODUCED BY AN AUTODESK STUDENT VERSION

KEY PLAN

Illustrated by Souparna Chanak WINDOW DIMENSIONS

1. FACADE 10° EAST OF SOUTH

2. FACADE 10° WEST OF NORTH

3. FACADE 20° WEST OF SOUTH

4. FACADE 20° EAST OF NORTH

Third Year | Section C | SPA Delhi

SOURCE- SUSTAINABLE BY DESIGN (https://susdesign.com/overhang_annual/index.php)

Ayushi Prerna Souparna Varad

INTERGRATED DESIGN - SCHEMATICS

SINGAPORE INTERNATIONAL SCHOOL | MKPL ARCHITECTS

ANALYSIS Column1

Column2 Carpet Area (m2)

Column3

CASE STUDY

Column4

Column5

Column6

Circulation Area (m2)

Wall Area (m2)

Built-up Area (m2)

Horizontal

Vertical

Ground Floor

3266.46

1709.59

425.56

150.66

5552.27

First Floor

2912.03

642..73

459.2

174.13

3545.36

Seond Floor

3521.44

751.92

480.31

165.63

4919.3

Third Floor

1936.61

669.85

392.12

162.73

3161.31

Fourth Floor

1374.91

432.79

336.12

125.71

2269.53

Total Built-up Area

01

Total Site Area: 26406m2 Maximum Building Height: 24.25m Allowable maximum height for type 1 Educational building - Unlimited (National Building Code of India 2016) Minimum Set-backs: Front- 9.8m, Side- 9.2m, Rear- 10m Allowable minimum set-back for a building height from 24m upto 27m is 9m from all side. (Haryana Building Code 2016)

19447.77

Ground Coverage:

Floor Area Ratio: Plinth Area

Ground Coverage =

Site Area =

5552.27 26406

= 0.2106 = 21.06% Allowable maximum Ground Coverage = 25% for site area over 10,000m2 (Haryana Building Code 2016)

Total Built-up Area

Floor Area Ratio =

Site Area =

19447.77 26406

= 0.7365 = 73.65% Allowable maximum Floor Area Ratio = 1.5 (Haryana Building Code 2016)

Illustrated by Souparna Chanak