ICMET

NATIONAL INSTITUTE FOR RESEARCH-DEVELOPMENT AND TESTING IN ELECTRICAL ENGINEERING

CRAIOVA

Short history

• ICMET Laboratories Department (HV & HP) was built within1968-1974, extended in 1978 and 1981 as part of CIMAE (Electrotechnical Industrial Group) based in Craiova at ELECTROPUTERE • Essential contribution for the implementation of 220 and 400 kV insulation classes in Romania. • Registered in 1982 at OMPI Geneva (World Intellectual Group) based in Craiova at ELECTROPUTERE • From 1990: Independent government-owned Research, Development & Testing National Institute for Electrical Engineering (self-financed) under aegis of Ministry of Education, Research, Youth and Sports

2

An Accredited Testing Center Today

What has the last decade brought?

A real revolution in the conception of MV & HV equipment: new basic materials, design concepts, standards, functions (metering, data transmission, monitoring - SCADA), life duration strategy

Consequence

High development expenses: about 25% used for performance evaluation - development, type & endurance tests, components quality certification - in the own laboratories and/or in independent accredited laboratories

Changes in Testing Concept

New test techniques, new measuring and testing equipment, introducing calibration laboratories, European & worldwide interlaboratories comparisons, all of them when the testing activity becomes a business aimed at meeting client requirements

Result

Assurance of long term confidence in the tested products quality: - through its equidistant position to the manufacturer and to the client - through the use of the most advanced testig/ measuring techniques

Most Important Competences

- HP & HV Power Transformer Testing - On-site Transformer PD Diagnosis & Locating by Electric & AE Methods - Thermal & AE PD Continuous Monitoring Systems for High Power Transformers - Switching Overvoltage Measurements in Power Grid - Special Tests: Free Electric Arc Tests on Line Insulator Strings, Internal Electric Arc Test on Instrument Transformers, Arresters Pressure Relief Test etc - EMC Tests

3

Mission.

New Activity Fields

ICMET Laboratories Department acts as a competence center in the field of research, development and testing and quality certification for electric equipment , permanently engaged in innovative certification contained in the research platforms of European Union, nationally and internationally recognized by accreditations got at European level in the field of high voltage, high current tests and electromagnetic compatibility.

New activity fields:

8Calibration of High Voltage and Current Measuring Devices, electric and magnetic field probes, force transducers 8Testing in regulated field: EMC, Low Voltage, Radio & Telecommunications Terminal Equipment 8Safety Tests for Arresters and Instrument Transformers 8AC/DC Cable Testing 8Transient Overvoltage Measurement in Power Grid 8On-site Diagnosis for Electric Power Equipment 8Development of Monitoring Systems for Power Transformers

4

Accreditations

RENAR Romanian Accreditation Association www.renar.ro

High Power Testing Laboratory LI - 004

Low and High Voltage Testing Laboratory LI - 1036

MRC Romanian Movement for Quality U Quality Management System – ISO 9001: 2008 U Environment Management System - ISO 14001: 2005 U Occupational Health and Safety Management System - OHSAS 18001: 2008

ANRE Romanian Energy Regulatory Authority www.anre.ro TRANSELECTRICA

Romanian Power Grid Company

www.transelectrica.ro

5

6 H - Preparation Room I - Test Control Room C1,÷C8 C1 C8- Testing Cells G1, G3 - Generators T1, T13 - Transformers

B - Routine Test High Voltage Hall

C - Open Area Test Site

D - Switching Equipment Hall

E - Reactances Hall

F - Generator Control Room

Total surface: 44 450 m2

G - Heat Run Tests

A - High Voltage Type Test Hall

High Voltage & High Power Laboratories Area

HIGH POWER DIVISION

RESEARCH, DEVELOPMENT DIVISION FOR ELECTRICAL EQUIPMENT AND ENERGY EFFICIENCY

Organization Chart - Laboratory Department

Research, Development Laboratory for Energy Efficiency and Power Quality

Research, Development Laboratory for Electrical, Electromechanical and Monitoring Equipment

High Power Testing Laboratory for Electrical Equipment High Power Research – Development Laboratory

HIGH VOLTAGE DIVISION

CALIBRATION LABORATORY

Research, Development Laboratory for High Voltage Technique

Low and High Voltage Testing Laboratory for Electrical Equipment (L & HVL)

7

Activities in Low & High Voltage Laboratory

This laboratory is equipped with ultimate measurement techniques which allow extensive testing of power transformers, instrument transformers and HV switching equipment, including type and special tests in accordance with international standards. Since 1995 , the Laboratory has been accredited by Romanian National Body RENAR

8

Activities in Low & High Voltage Laboratory - HV Tests MEASURING TECHNIQUE High Voltage measuring systems formed of dividers, peak voltmeters and Transient Recorders • Lightning and switching impulse divider 643/4200 [pF] / [kV] (mounted together with the generator) • Lightning impulse divider 10/2200 [kW] / [kV] Response time - 27 ns • Lightning impulse divider 10/770 [kW] / [kV] Response time - 10 ns IMPULSE lightning [kV] 4200 (336kWs) 700 (4.9kWs)

switching [kV] 2600 300

AC

• AC capacitive divider 160/1200 [pF] / [kV] (mounted together with AC cascade) • AC capacitive divider 200/1800 [pF] / [kV] (mounted together with the upper unit in outdoor field)

(25 to 150) Hz

[kV] 1200

• Reference measuring systems according to IEC60060-2 for LI ( SI ), AC , DC voltages and Impulse Charge for PD measurements, having traceability to PTB

[A] 1.2 50 Hz

[kV] 200 350 3x250 (resonant system)

[A] 1.0 1.0 1.0

• Equipment specialized to record HV transient phenomena (Transient recorder 10 bit , 100 MS/s , 4 channels)

(25 to 150) Hz three phases

[kV] 15; 35; 110

[MVA] 5

(min) 2

DC [kV] 1100

[mA] 30

• Equipment specialized to measure partial discharges by electrical and ultrasonic methods with PD free sources • Equipment to measure atmospheric conditions during HV tests

9

Activities in Low & High Voltage Laboratory

OFFERED SERVICES 8 High voltage tests for HV equipment (transformers, cables, switchgear, GIS etc.) inside the electromagnetic screened hall of ICMET - Full wave and tail chopped wave voltage impulse tests at voltages up to 4200 kV and energy 336 kWs - Applied voltage tests at frequencies between 25 and 150 Hz up to 1200 kV - Single and three-phase induced voltage tests, 5 MVA, 2 min. - DC voltage tests up to 1100 kV 30 mA - Oscillating switching impulse tests - Aperiodic switching impulse tests up to 2600 kV - External insulation test under artificial rain for equipment up to 550 kV rated voltage - Partial discharge and radio interference measurements - Combined voltage tests: LI - AC, SI - AC, DC - LI, DC - SI - Electrical & mechanical test of polymer insulators, salt fog ageing inclusively - Instrument transformers error before and after short circuit testing

8 High voltage tests on site: - Partial discharge measurement at instrument and power transformers by electric and ultrasonic method - Power transformer and cables dielectric spectroscopy - Checking windings mechanical condition of power transformers by FRA method - Humidity assessment for large power transformer insulation system

10

Activities in Low & High Voltage Laboratory

PD Acoustic Emission Technique

Number of test reports

Tests Performed by L & HV Testing Laboratory

700 600

624

500 400 300

495 410

439

590

468

423

394

364

200 100 0 2008

2009

2010

2011

2012

Year

2013

2014

2015

2016

11

Activities in Low & High Voltage Laboratory - EMC Tests This facility is the most important EMC Collective in Romania. In 2000 it was put into operation the semi-anechoic chamber, the first of this kind in Romania. At present the immunity tests and conducted disturbance measurements performed by this Collective are accredited by RENAR.

12

Activities in Low & High Voltage Laboratory - EMC Tests Semi-anechoic chamber (SAC) from ICMET Craiova Technical Characteristics • Immunity according to EN 61000-4-3 In the measuring area (L x H=1.5 x 1.5 m) uniform field within imposed tolerance limits (0dB +6dB) for at least 75% of the area (12 of 16 measuring points) Test distance: 3 m Provisions of EN 61000-4-3 are guaranteed within the frequency range: 80MHz-2GHz Test distance: 1 m Provisions of Automotive Directive 2004/104/EEC and ISO 11452 are guaranteed within the frequency range: 20MHz - 2GHz • Conducted disturbance power measurement for LV equipment according to CISPR 16, EN 55014-1 • Radiated disturbances according to MIL-STD-461 and Automotive Directive 2004/104/EEC, EN 55025, EN 55012

Conducted immunity and emission tests EMC Tests according to: IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN IEC/EN

61000-4-2 ESD 61000-4-4 Burst 61000-4-5 Surge 61000-4-6 RFCD 61000-4-8 50 Hz magnetic field 61000-4-9 Surge magnetic field 61000-4-11 Voltage dips and interruption 61000-4-12 Ring wave 61000-4-13 Harmonics

IEC/EN 61000-4-18 DOW EN 55011, EN 55022 Conducted emission EN 55015 Electrical lighting equipment EN 55017 Insertion loss IEC/EN 61000-3-2 Harmonic current IEC/EN 61000-3-3 Flicker ISO 10605 ESD ISO 7637-1,2,3 Automotive EN 50147-1, IEEE 299 Shielding Effectiveness

13

Activities in Low & High Voltage Laboratory The laboratory provides tests compliant with the international regulations in force, taking into account the development and rapid innovation of the wireless technology, aiming at people protection in relation with harmful influence of electromagnetic radiation.

European/International EMF standards U EN 50360: Products standard mobile phone handsets U EN 50361: Basic standard mobile phone handsets U IEC 62209-1(up to 3GHz): Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices

The laboratory is able to carry on the following activities: _ Experimental dosimetry and numerical simulation for mobile phones; _ Testing technologies for small dimension mobile terminals (WLAN, Bluetooth, ZigBee etc); _ Bioelectromagnetism matters; _ Pacemaker implants behaviour; _ Risk evaluation of mobile phones use in conformity with the safety standards; _ Interlaboratory comparisons; _ Market surveillance.

14

Activities in Low & High Voltage Laboratory - Low Voltage Tests Main testing equipment Safety compact tester: - HV generator up to 5 kV AC; - PE resistance measurement up to 0,5Ω Impulse generator 1.2/50μs up to 20 kV Digital megohmmeter up to 5 kV Power clamps up to 2 kA Digital thermometer with PT 100 probe Pendulum and spring hammers

Main tests LV Directive 2006/95/EC Dielectric tests: - insulation resistance - dielectric strength - clearances and creepage distances Protection against electric shock: - PE circuit test - marking Operating tests: - power and current measurement - heating Mechanical impact tests

Products to be tested LV switchgear and controlgear assemblies (IEC 61439) Auxiliary and control circuits of HV switchgear and controlgear (IEC 62271) Household appliances (IEC 60335) Information technology equipment (IEC 60950) LV switchgear and controlgear (IEC 60947) Electrical equipment of machinery (IEC 60204) Handheld tools (IEC 61029) Audio and video apparatus (IEC 60065) Electrical equipment for measurement, control and laboratory use (IEC 61010) Electrical toys (IEC 62115)

15

Activities in Low & High Voltage Laboratory - Tracking & Erosion Tests Tracking and erosion test on composite insulators is a compulsory design and type test, according to IEC 62217: HV polymeric insulators for indoor and outdoor use . The type tests are performed on the composite-type insulators which passed the design tests. These tests determine, to the highest degree, the quality of composite insulators which will replace entirely in the near future (due to their technical-economic and environment protecting advantages) the porcelain or glass insulators

» Wheel test

16

Activities in Low & High Voltage Laboratory - Tracking & Erosion Tests » Wheel test

17

Activities in Low & High Voltage Laboratory » 1000 h salt fog test Test requirements: ¨ Test voltage: it is calculated based on actual creepage distance ¨ Initial salt content: it is determined based on the speciment dimensions

Reference standards: • EN 62217 Polymeric insulators for indoor and outdoor use with a nominal voltage > 1000 V - General definitions, test methods and acceptance criteria

18

Activities in High Power Laboratory Since 1995, the Laboratory has been accredited by Romanian National Body RENAR ( member of ILAC and EA) according to EN ISO 17025

Direct Testing Circuit · Three Short Circuit Generators Rated Power 2500 MVA 120 kA · Six Three-Phase Units of Circuit Breakers 12 kV, 120 kA · Three Units of Making Switches 12 kV, 330 kA · Nine Single-Phase Step up Transformers 80 MVA 12/12/25/51kV · Four Single-Phase Step Down Transformer 40 MVA 10/0.5 kV · Eight Test Cells · Temperature-rise test installation, up to 10 kA AC · HV Disconnector type pantograph test installation 525 kV, 60 kA/1s · Digital Measuring System 100 MS/s, 16 bit, 16 Channels

19

Activities in High Power Laboratory

Three short-circuit generators type TI - 100 - 2, 2500 MVA, 12 kV, 120 kA, 50 Hz with parallel operation possibility

12 kV - 120 kA 72.5 kV - 20 kA

Three - phase tests:

Single - phase tests:

500 V - 135 kA/3s

1000 V - 250kA/3s

12 kV - 120 kA 123 kV - 25 kA

12 kV; 330 kA peak; accuracy ±5º el.

20

Activities in High Power Laboratory OFFERED SERVICES • Switching capacity test of the MV and HV circuit breakers, safety fuses, switch disconnectors and MV contactors • Dynamic and thermal stability test of HV and LV apparatus, line elements, cables and metal enclosed switchgear • Ability to withstand the dynamic effects of short-circuit test of transformers rated up to 120 MVA • Temperature rise tests of the current path of electric apparatus, line components, bars, with rated current up to 10 kA AC • Temperature rise tests on power transformers, reactors and instrument transformers • Mechanical endurance test for circuit breakers, disconnectors and contactors • Short-circuit tests on surge arresters and short-circuiting and earthing systems • Internal arcing tests on switchgear, prefabricated substations and instrument transformers • AC Power arc tests on insulators for overhead lines

21

Activities in High Power Laboratory

Temperature - rise test

Tests Performed by High Power Testing Laboratory

Number of test reports

400 350 340

300 250

296

295

310 273

280

2012

2013

260

260

250

2014

2015

2016

200 150 100 50 0 2008

2009

2010

2011

Year

22

Activities in in High High Power Power Laboratory Laboratory Activities

Internal arc test for metal enclosed switchgear

Internal arc test on transformer substation 23

Activities in in High High Power Power Laboratory Laboratory Activities

Internal arc test for instrument transformer

Power arc test on insulator strings 24

Activities in in High High Power Power Laboratory Laboratory Activities

Switch-Disconnectror making and breaking test

Breaking test for drop-out expulsion fuses 25

Activities in in High High Power Power Laboratory Laboratory Activities

Internal arc test inside switch disconnector

making and breaking tests on circuit breaker 26

Activities in in High High Power Power Laboratory Laboratory Activities

Short time Withstand current test on intrument transformer

Test on pretective cloth

27

Calibration Calibration Laboratory Laboratory

Laboratory calibration Measured quantity / Calibration item

DC Voltage

AC Voltage HV Impulse (LI) Time parameters T1 T2 HV Impulse (SI) Time parameters Tp T2 Impulse charge q Indication linearity

Measurement conditions / procedure

Range 350 mV 10 kV 25 kV 350 kV 1V 25 kV 200 kV 210 kV 25 kV 500 kV 0.8 ms 40 ms 210 kV 25 kV 200 ms 1000 ms 2 pC 2 pC

to to to to to to to to to to to to to to to to to to

1000 V 200 kV 350 kV 1000 kV 1000 Vk 200 kV 1200 kV 215 kV 500 kV 1800 kV 1.6 ms 60 ms 215 kV 500 kV 300 ms 4000 ms 2000 pC 2000 pC

10 Hz to 10 kHz 50 Hz to 150 kHz Acc. to IEC 60060 Acc. to IEC 60060

Acc. to IEC 60060

Acc. to IEC 60270

Best measurement capability 1) 0.2 % 0.2 % 0.4 % 1.0 % 0.11 % 0.6 % 0.9 % 0.6 % 0.7 % 0.8 % 4.0 % 4.0 % 0.6 % 0.7 % 4.0 % 4.0 % 0.4 pC + 0.03 q 0.3 pC + 0.03 q

On-site calibration DC voltage AC voltage Impulse voltage (LI) Time parameters T1 T2 Impulse voltage (SI) Time parameters Tp T2

28

30 kV 30 kV

to to

200 kV 200 kV

25 kV 0.8 ms 40 ms 25 kV 200 ms 1000 ms

to to to to to to

500 kV 1.6 ms 60 ms 500 kV 300 ms 4000 ms

Acc. to IEC 60060 50 Hz to 150 Hz Acc. to IEC 60060 Acc. to IEC 60060

0.7 % 0.7 %

Acc. to IEC 60060

0.8 % 4.5 %

0.8 % 4.5 %

Calibration Laboratory - Electromagnetic field

Measurand/ calibration item HF Electric Field Strength E/ HF Electric Field Strength Meters

Measuring range

10 V/m - 60 V/m

Standards and procedures 80 MHz - 2 GHz Antenna - EUT Distance 1m - 2m Uniform electric field zone 3 [100 x 100 x 100] mm

Uncertainty of measurement: 1 dB

HF Electric Field Strength Meters

50 Hz Magnetic Flux Density Meters

Antenna Field Calibration System

Measurand/ calibration item Magnetic Flux Density B/ Magnetic Flux Density Meters

Magnetic Field Calibration System

Measuring range

Standards and procedures

10mT≤ B < 900mT

50 Hz Uniform magnetic field zone [180 x 180 x 140] mm3

Uncertainty of measurement: 0.7%

29

Calibration Laboratory - Force The lab is the result of close co-operation between ICMET and the German National Metrology Institute PTB. It was put into operation in 1995 and it is to be used for measurement range from 1 MN to 32 MN. The 32 MN force calibration machine has direct traceability to the German metrology standard PTB - Braunschweig. The lab performs tests and calibrations for the force measuring equipment used in metallurgy, off-shore drilling and other industrial applications. The lab provides technical facilities for a rapid manufacturing of the various accessories that are necessary for the tests.

OFFERED SERVICES v Tests, Measurements and Calibrations for Force and Mass Measuring Equipment

30

Calibration Calibration Laboratory Laboratory High Currents The Lab offers calibrations for: Shunts & Rogowski coils - Scale factorTESTS tests CALIBRATION

(symmetrical current) - Linearity tests (asymmetrical current) - Step response - Ohmic resistance measurements

Calibrations in permanent locations S.N.

Measured quantity/ object under calibration

CMC Measurement range

Extended calibration uncertainty

Measurement conditions

Observations

1

High alternating current/ shunt and Rogowski coil

From 100 Aeff to 140 kAeff From 250 Apeak to 350 Apeak

1.5%

50 Hz IEC 62475

2

Time parameter, rise time TN / shunt

From 24 ns to 1000 ns

2.5%

IEC 62475

The total rise time includes the rise time of generator and measurement system

3

Resistance/ shunt resistor

From 4 μΩ to 200 4 μΩ

2.0% 0.1%

Temperature: (22+/-2)0C Humidity: (50+/-10)% rH/ IEC 62475

The uncertainty is in accordance with the apparatus measurement range

[V]

Shunt to be calibrated

[kA]

Reference standard shunt

Scale factor determination at 20 kArms

[kA]

Shunt to be calibrated

Linearity determination at 50 kApeak

[kA]

Step response at 2 kA coaxial shunt Reference standard shunt

31

Activities in Low & High Voltage Laboratory

DIELECTRIC TESTS AND PHYSICAL-CHEMICAL DIAGNOSIS OF ELECTRO-INSULATING SOLID MATERIALS

Electroinsulating varnishes, paints • coating thickness determination (EN ISO 2808) • coating adherence determination (EN ISO 2409)

Metallic protection coat • metal adherence determination (EN ISO 2819) • layer thickness determination (EN ISO 2409)

Core of polymeric insulators • porosity and water penetration test (IEC 62217)

Cellulosic insulation: electro-insulating board and paper • dielectric tests (dielectric strength, tan σ, permittivity) (IEC 60296) • measurement of the degree of polymerization (IEC 60450)

32

Low & High Voltage Laboratory

DIELECTRIC TESTS AND PHISICAL-CHEMICAL DIAGNOSIS OF OIL TRANSFORMER

• determination of dielectric strength (IEC 60156)

• water content determination (IEC 60814) • interfacial tension determination

(IEC 60296)

• DGA analysis (IEC 60567) • determination of oxidation stability (IEC 61125)

• measurement of dielectric dissipation factor (IEC 60247) • determination of sulfur corrosive action (ISO 2160) • determination of flash point (SR EN ISO 2719) • determination of moisture saturation degree (IEC 60422) • neutralization number • particle count determination determination (IEC 62021) (IEC 60970) 33

Low & High Voltage Laboratory The Collective for mechanical and environmental tests, carries out complex tests on electrical materials, products and subassemblies in accordance with international standards . The collective offers the following services:

FIRE HAZARD TESTING • needle flame test (IEC 60695-11-5) • horizontal and vertical flame test (IEC 60695-11-10)

• abnormal heat test. Ball pressure test (IEC 60695-10-2)

• determination of proof and comparative tracking indices (IEC 60112)

• glow wire test (IEC 60695-2-10,11,12,13)

• determination of horizontal burning characteristics of cellular plastics(ISO 9772+A1)

34

Low & High Voltage Laboratory

ENVIRONMENTAL TESTS TMin

: - 40o C

T max

: + 180 o C

Humidity

• • • • • •

max

: 99%

damp heat test (IEC 60068-2-78, IEC 60068-2-30) dry heat test (IEC 60068-2-2) cold test (IEC 60068-2-1) temperature change test (IEC 60068-2-14) salt mist test (IEC 60068-2-11) salt mist cyclic test (IEC 60068-2-52)

SPECIAL TESTS • water penetration test at electric cables (IEC 60502-2,HD 605.S2) • waterproof test (ingress of moisture)(IEC 60282-1) • sulfur dioxid test with general moisture condensation (SR EN ISO 6988) • determination of the indentation hardness of plastics, rubber and ebonite(shore hardness) (SR EN ISO 868)

35

HV Interlaboratory Comparison EU - COPERNICUS

Comparative Measurements with HIGHVolt TRMS: DC, AC, LI, SI

ERB-CIPA-CT 940137 1996

Project Manager: HighVolt Dresden

FP 5

Traceability and Mutual Recognition of Impulse Voltage Measurements: LI

SMT4-CT98-2270 1998-2002

Project Manager: Tech. Univ. Helsinki

DKD Ringvergleich

Comparative Measurements with ICMET TRMS: DC, AC, LI, SI

2002

Project Manager: PTB Braunschweig

STL High-Current Inter-Calibration Project

Inter-comparison tests of the STL reference shunt and the shunt owned by ICMET Project Manager: ST L

2012

COPERNICUS 1996

ICMET Craiova - HUT Helsinki

STL Rugby UK- ICMET Craiova

DKD Ringvergleich 2002

36

International Cooperation

Force Calibration Lab Dr.D.Peschel, , Dr.A.Sawla

PTB

High Voltage Lab

1991- 2007

Dr.K.Schon

High Frequency Lab Prof.J.Glimm , Dr.T.Schrader

IEH Karlsruhe 1991-2004

NTUA Athens 19961996-1998

TU Eindhoven 19961996-1998

TU Berlin 2004 IEH Karlsruhe 2004-2006

NIKDIM Kazanlak 2004-2006 2005-2012

IEH- Prof.A.J.Schwab, Prof.T.Leibfried, Prof.A.M.Miri EMC, Transients in Power Transformers, Seismic Phenomena, Diagnosis & Monitoring

EE Faculty

- Prof.I.Stathopoulos

PD Measurements

EE Faculty

- Prof.G.Damstra

HP Measuring Technique, Synthetic Tests

IEH

- Prof. W. Kalkner

On line PD Measurement, Clamping Forces in Transformers

IEH

- Prof. T. Leibfried

Methods for on-site testing of transformers Experimental data processing

NIKDIM

- Maria Georgieva

Tests for verifying the breaking capacity of fuses Switching tests on load break switches 37

Clients Portofolio

ABROAD ROMANIA About 50 companies • AEM LUXTEN LIGHTING • CN TRANSELECTRICA • ELECTRO ALFA INTERNATIONAL • ELECTROPUTERE • ELECTROSISTEM • ELECTROSTANDARD • ELEROM • EMON ELECTRIC • ENERGOBIT • ICEMENERG • IPROEB • ICPE • IMSAT • NOVA INDUSTRIAL • ROMIND

38

About 70 companies • Bosnia and Herzegovina • Bulgaria • Canada • Denmark • France • Greece • Israel • Iran • Italy • Macedonia • Montenegro • Portugal • Serbia • Slovenia • Spain • Switzerland • Syria • Turkey • Taiwan • Ukraine

ICMET Fellowships • IEC (www.iec.ch), since 1976 TC 14 Power Transformers TC 36 Insulators TC 42 High-Voltage Testing Techniques TC 42 WG 12 High Current Testing Techniques • CIGRE (www.cigre.org), since 1993 WG A2.25 - Bushing Reliability WG A2.26 - Mechanical condition assessment (guidance, FRA) TF A2.27 - Recommendations for monitoring facilities WG A3.12 - Circuit Breaker Controls WG D1.33 - High Voltage Test and Measuring Techniques WG D1 - Materials and Emerging Technologies • IEEE (www.ieee.org), since 1994 PES - Power Engineering Society EMCS - Electromagnetic Compatibility Society IMS - Instrumentation and Measurement Society IAS - Industry Applications Society PELS - Power Electronics Society DEIS - Dielectrics and Electrical Insulation Society SPS - Signal Processing Society APS - Antennas and Propagation Society • STL - Short-Circuit Testing Liaison, since 1999 • ACER - Romanian EMC Association (www.acero.ro) Founding Member since 1997

39

ICMET Headquarter Building

Acces to ICMET Craiova By plane plane (International (International Flights): Flights): By Craiova -- 44 Km Km -- Craiova Bucharest (240 (240 Km Km to to Craiova) Craiova) -- Bucharest Sibiu (225 (225 Km Km to to Craiova) Craiova) -- Sibiu Timisoara (330 (330 Km Km to to Craiova) Craiova) -- Timisoara

By train:

By car: - from Belgrad - 360 Km - from Budapest - 661 Km - from Istanbul - 834 Km - from Sofia - 320 Km

- Bucharest (240 Km to Craiova)

Decebal Ave. No. 118A 200746 Craiova, Romania Phone: +40 351 404 888; Fax: +40 351 404 890 E-mail: [email protected]; [email protected] www.icmet.ro