Main catalog
Softstarters Type PSR Type PSS Type PST/PSTB
New
Torque control
The latest version of the PST(B) softstarter offers a new functionality called Torque control. With this function enabled the voltage of the motor is regulated so that the torque follows a predefined torque curve during start and stop. Torque control is especially useful in pump applications where a sudden stop can cause water hammering and pressure surges.
So
fts
Analog output New With the latest version of the PST(B) softstarter it
is possible to have analog output signals from the softstarter. These signals can then be used as input to a PLC or an analog meter.
Ne
Type PSR Softstarter New The latest addition to the ABB softstarter range is the
New
tar
ws
ter
s
compact PSR softstarter. This new softstarter has a compact, attractive design and is ideal for installation in places where space is limited and where there is a demand for easy installation.
Complete range
With the new PSR softstarter, ABB offers a complete range of softstarters from 3 to 1810 A. This complete range consists of the three models PSR, PSS and PST(B).
ABB Softstarters – the complete range Functionality
PST/PSTB
PSS
Advanced
Flexible
PSR
Compact
45
515
1810 Ampere
Softstarters
So
fts
ta r e P ters SS
Ty p
1
Contents
Page General.................................................................................................................................. 4 The complete range............................................................................................................... 5 Softstarters, type PSR Overview................................................................................................................................ 6 Description............................................................................................................................. 7 Ordering (incl. accessories)..................................................................................................... 8 Technical data, UL ratings...................................................................................................... 9 Softstarters, type PSS Overview.............................................................................................................................. 10 Application and Description.................................................................................................. 12 Ordering............................................................................................................................... 14 Accessories.......................................................................................................................... 18 Technical data...................................................................................................................... 19 UL ratings............................................................................................................................ 21 Softstarters, type PST Overview.............................................................................................................................. 22 Application and Description.................................................................................................. 24 Ordering............................................................................................................................... 26 Accessories.......................................................................................................................... 30 FBP Field Bus Plug............................................................................................................... 31 Technical data...................................................................................................................... 37 UL ratings............................................................................................................................ 41 Wall mounting instruction..................................................................................................... 42 Dimensions.......................................................................................................................... 43 Circuit diagrams................................................................................................................... 46 Certifications and approvals................................................................................................. 49 Leader in power and automation technologies, Division Automation Products, Low voltage products........................................................... 51
Some information about the catalogue: Ordering details: When placing an order please give either the ”Type” or the ”Order code”. Please note that for some of the products you need to fill in some additional code letters/code numbers to define the complete Type/Order code. Packing: All softstarters and most of the accessories are delivered in an individual packing. Some of the accessories are packed together in batches of ”n” pieces (see ordering ”Packing pieces”). For these items, please order the total amount corresponding to a multiple of the number in the packing. Example: If two in the packing, then please order minimum two, four, six etc. Note: Each ”Type” or ”Order code” always corresponds to only one piece. The products described in this catalogue are subject to change (design, . dimensions, technical data, etc.) without prior notice.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
te ar
t
ts
1
f So
SS
P pe
Ty
Softstarters From the moment the first electrical motors appeared, engineers have been searching a way to avoid electrical and mechanical problems that occur using Direct-on-Line and Star-Delta starters. ABB has been producing softstarters since the beginning of the 1980’s. The valuable experience gained since the early 80’s has been incorporated into the design of today’s product ranges. With the latest series named PST, ABB has taken a significant step further in soft starting technology. Matching modern power electronics with smart circuitry and software, the new PST softstarter offers superior electronic control of the current and voltage during motor start-up, in addition to several new design features.
The solution to both mechanical and electrical problems
Motor voltage V
DoL
Star/Delta
Softstart
100 %
70 % 58 % 30 %
Adjustable ramp slope
Time
Motor current I DoL
AC motors, “the workhorse of the industry”, that are used to drive fans, crushers, agitators, pumps, conveyors etc., are . unnecessarily causing unwanted load peaks day in and day out in production plants all over the world. These violent starts cause damage in several ways. Among them are:
Star/Delta
Softstart
● Electrical
problems due to voltage and current transients arising from Direct-on-Line or Star-Delta starts. Such transients may overload the local supply network and cause unacceptable voltage variations that interfere with other electrical equipment connected to the network.
● Mechanical
problems that address the entire drive chain, from motor to driven equipment, to severe stress.
Operational problems, such as pressure surges in pipelines, damage to products on conveyor belts and uncomfortable escalator rides.
Motor speed
Torque
●
The financial consequences are considerable: every technical problem and every breakdown, costs money – in terms of repairs as well as lost production.
T
DoL
Star/Delta
Softstart
The easy solution to all of these problems is to install an ABB Softstarter type PSR, PSS or PST. With ABB Softstarters, it is possible to start and stop smoothly while keeping mechanical and electrical stresses to a minimum. Motor speed Graphs showing the basic differences between direct-on-line starting (DoL), star-delta starting and soft starting in terms of the motor voltage (V), motor current (I) and motor torque (T).
1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
fts
ta r e P ters SS
Ty p
1
ABB softstarters – The complete range ABB offers three different ranges of softstarters to cover every customer need for solutions for small to mediumsized motor applications, from 3 A to 1810 A. The overview table at the bottom of this page shows the main characteristics of the different types. For more specific technical details and ordering data, see the following pages.
Compact Range
Type PSR, covers motor currents from 3 to 45 A. It is the latest addition to the softstarter family and has an attractive, compact design. Further, the system concept includes MMS and the softstarters are available for remote control connection using the FieldBusPlug as an accessory. All sizes include a Run signal relay, while from sizes 25 A the PSR Softstarters are also provided with an output signal for TOR (Top Of Ramp), i.e. full voltage). With standard performance the PSR Softstarters handle ten starts per hour. When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour. • Current ratings 3.9 – 45 A (1.5 - 22 kW), at 400 V • Motor voltage 208 – 600 V • Supply voltage 24 V DC or 100-240 V AC • Easy to install and adjust • DIN rail or screw mounting • Integrated by-pass contacts With their compact design, the PSR Softstarters are ideal for installation in places where space is limited and where there is a demand for easy installation.
Flexible Range
Type PSS, covers motor currents from 18 to 300 A and offers a flexible solution with easy installation and setup. • Flexible: With two connection possibilities, either in line with the motor or inside the motor delta. It can also be equipped with current limit. • Easy to set up: With just three clearly labeled rotary switches on the front of the unit it is possible to adjust the PSS Softstarter for a wide range of applications. • Solid state electrical circuit: This ensures the highest reliability and reduces maintenance to a minimum, even in applications with frequent starts and stops.
Advanced Range
Type PST(B), covers motor currents from 30 to 1050 A and provides advanced functionality, including integrated protections, programmable signal relays, a flexible communication Low Voltage Products & Systems
system and an LCD display. Sizes PSTB370 to 1050 A include a by-pass contactor. • Advanced integrated protections: For the motor; inte- grated electronic overload relay, phase monitoring relays, high current and PTC protection. For the Softstarter; ad- vanced thyristor protection. • Flexible bus communication system: By using the ABB FieldBusPlug (FBP), you can decide at any time which bus system to select within the ABB FBP range. The interface between the PST Softstarter and the ABB FBP is always the same, independent of size and delivery date. • LCD display: With 13 languages, a menu system similar to your mobile phone, preprogrammed application settings and automatic status and event logging, it couldn’t be easier to set up and operate! • Programmable signal relays: gives you several possi bilities for signalling warnings, faults and other events. • Torque control: allows you to start and stop motors with a more linear acceleration than when using voltage ramp. PSR3 ...45 PSS18/30 ...300/515 PST30 ... PSTB1050B O – – – – – – – – – – – – – • • • – –
– – – – – – – – – – – – O • • – • – –
• • • • • • • • • • • O • • • • 1) • • •
• Standard O Optional – Not available
Field bus communication enabled Real time clock Programmable fault supervision functions Programmable warning functions PTC input for motor protection High current protection Phase imbalance /phase reversal protection Locked rotor protection Thyristor overtemperature protection Motor overload protection Four button keypad (external keypad available) External keypad Current limit control In Line and Inside Delta connection LED indications Built-in by-pass contactor (1) On PSTB) Ramp Start/Stop Torque control Analog output
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
pe Ty
Softstarters Type PSR Overview
SS
P
PSR3 ... PSR16
Normal start: In Line connected 400 V kW A In Line connected 480 V hp A
If using manual motor starters type 1 coordination will be achieved.
Softstarter, Type PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
1.5 3.9 2 3.4
3 6.8 3 6.1
4 9 5 9
5.5 12 7.5 11
7.5 16 10 15.2
11 25 15 24.2
15 30 20 28
MS116
MS116
MS325
MS450
400V, 40 °C Manual motor starter, Type MS116
MS116
10 A
Switch fuse, Type
Suitable switch fuse for the
OS32D
above gG fuses..
The line contactor is not required for the softstarter itself but often used to open if OL trips.
MS116
Fuse protection 400 V, 65 kA, 40 °C, gG Fuse
Using gG fuses type 1 coordination will be achieved.
PSR25 ... PSR30
16 A OS32D
25 A
32 A
32 A
50 A
63 A
OS32D
OS32D
OS32D
OS32D
OS32D
A9
A12
A16
A26
A30
TA25DU
TA25DU
TA25DU
TA25DU
TA25DU
Built-in
Built-in
Built-in
Built-in
Built-in
Line contactor, Type A9
A9
Thermal overload relay, Type
The overload relay is always
TA25DU
required to protect the motor.
1SXU 132 019 C0202
TA25DU
By-pass contacs Built-in
Built-in
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
ta r e P ters SS
Ty p
Type PSR Overview and description
1
Description PSR - Compact range, covers motor currents from 3 to 45 A. It is the latest addition to the softstarter family and has an attractive, compact design. Further, the system concept includes MMS and the softstarters are available for remote control connection using the FieldBusPlug as an accessory. All sizes include a Run signal relay, while from sizes 25 A the PSR Softstarters are also provided with an output signal for TOR (Top Of Ramp), i.e. full voltage. With standard performance the PSR Softstarters handle ten starts per hour. When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour.
PSR37 ... PSR45 Softstarter, Type PSR37
PSR45
18.5 37
22 45
25 34
30 46.2
400V, 40 °C Manual motor starter, Type MS450
• Current ratings 3.9 – 45 A (1.5 - 22 kW), at 400 V • Motor voltage 208 – 600 V • Supply voltage 24 V DC or 100-240 V AC • Easy to install and adjust • DIN rail or screw mounting • Integrated by-pass contacts With their compact design, the PSR Softstarters are ideal for installation in places where space is limited and where there is a demand for easy installation.
Settings
MS450
Fuse protection 400 V, 65 kA, 40 °C, gG Fuse 100 A
125 A
Switch fuse, Type OS63D
1
OS125D
3
Line contactor, Type A40
2
A50
Thermal overload relay, Type TA42DU
TA75DU
By-pass contacts Built-in
Built-in
U
3 U ini
time Start
Stop
1
2
1 Ramp time START = 1 ... 10 sec 2 Ramp time STOP = 0 ... 20 sec 3 Initial voltage U =40 ... 70 % ini
(also set ”end voltage”)
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
pe Ty
Softstarters
SS
Type PSR3 ... PSR45 Ordering details
P
Motor power
IEC
230 V Pe kW
500 V Pe kW
Max rated motor current, Ie A
400 V Pe kW
Type
Order code
Weight kg 1 piece
PSR3-600-70 PSR6-600-70 PSR9-600-70 PSR12-600-70 PSR16-600-70 PSR25-600-70 PSR30-600-70 PSR37-600-70 PSR45-600-70
1SFA 896 103 R7000 1SFA 896 104 R7000 1SFA 896 105 R7000 1SFA 896 106 R7000 1SFA 896 107 R7000 1SFA 896 108 R7000 1SFA 896 109 R7000 1SFA 896 110 R7000 1SFA 896 111 R7000
0.45 0.45 0.45 0.45 0.45 0.65 0.65 1.00 1.00
PSR3-600-81 PSR6-600-81 PSR9-600-81 PSR12-600-81 PSR16-600-81 PSR25-600-81 PSR30-600-81 PSR37-600-81 PSR45-600-81
1SFA 896 103 R8100 1SFA 896 104 R8100 1SFA 896 105 R8100 1SFA 896 106 R8100 1SFA 896 107 R8100 1SFA 896 108 R8100 1SFA 896 109 R8100 1SFA 896 110 R8100 1SFA 896 111 R8100
0.45 0.45 0.45 0.45 0.45 0.65 0.65 1.00 1.00
208 – 600 V AC Supply voltage, Us 100-240 V AC PSR3 ... PSR16
PSR25 ... PSR30
PSR37 ... PSR45
0.75 1.5 2.2 3 4 5.5 7.5 7.5 11
1.5 3 4 5.5 7.5 11 15 18.5 22
2.2 4 4 5.5 7.5 15 18.5 22 30
3.9 6.8 9 12 16 25 30 37 45
Supply voltage, Us 24 V DC 0.75 1.5 2.2 3 4 5.5 7.5 7.5 11
1.5 3 4 5.5 7.5 11 15 18.5 22
2.2 4 4 5.5 7.5 15 18.5 22 30
3.9 6.8 9 12 16 25 30 37 45
Accessories Type
Order code
Weight kg 1 piece
Fieldbus Plug Connection Accessory The same accessory for all sizes
PSR-FBPA
1SFA 896 312 R1001
0.06
Connection kit for PSR3-16 and MS116
PSR16-MS116
1SFA 896 211 R1001
0.03
Connection kit for PSR37-45 and MS450
PSR45-MS450
1SFA 896 213 R1001
0.03
PSR-FAN
1SFA 896 311 R1001
0.01
Description
PSR-FBPA
PSR16-MS116
PSR45-MS450
Fan All sizes can be equipped with auxiliary cooling fan for increased starting capacity. Suitable for all sizes.
PSR-FAN
ABB Field Bus Plug Suitable for all sizes.
1SXU 132 019 C0202
FieldBusPlug Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PSR3 ... PSR45 Technical data Rated insulation voltage, Ui
600 V
Rated operational voltage, Ue
208...600 V
Rated supply voltage, Us
100...240 V AC or 24 V DC
Power consumption, at 100-240 V AC at 24 V DC
PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR45
12 VA 5 W
12 VA 5 W
12 VA 5 W
12 VA 5 W
12 VA 5 W
12 VA 5 W
12 VA 5 W
10 VA 5 W
10 VA 5 W
Rated operational current, Ir
PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR45
3.9 A
6.8 A
9 A
12 A
16 A
25 A
30 A
37 A
45 A
Starting capacity at Ir
4 x Ir for 6 sec.
Number of starts per hour, with aux. fan
standard 10 (4 x Ie during 6 s) 20 (4 x Ie during 6 s)
Service factor
fts
ta r e P ters SS
Ty p
1
100 %
Ambient temperature
during operation during storage
Maximum altitude 2)
4000 m
1)
Degree of protection, main circuit control circuit Connectable cable area, main circuit
control circuit
-25 °C to +60 °C -40 °C to +70 °C PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR45
IP20 IP20
IP20 IP20
IP20 IP20
IP20 IP20
IP20 IP20
IP20 IP20
IP20 IP20
IP10 IP20
IP10 IP20
PSR3 - PSR16
PSR25 - PSR30
PSR37 - PSR45
1 x 0.75 - 2.5 mm2 2 x 0.75 - 2.5 mm2 PSR3 - PSR16 1 x 0.75 - 2.5 mm2 2 x 0.75 - 2.5 mm2
1 x 2.5 - 10 mm2 2 x 2.5 - 10 mm2 PSR25 - PSR45 1 x 0.75 - 2.5 mm2 2 x 0.75 - 1.5 mm2
1 x 6 - 35 mm2 2 x 6 - 16 mm2
PSR3 - PSR16
PSR25 - PSR45
Signal relays for Run signal Resistive load AC-15 (Contactor) for Top of Ramp signal Resistive load AC-15 (Contactor)
240 V, 2 A 240 V, 0.5 A
250 V, 5 A 250 V, 0.5 A
- -
250 V, 2 A 250 V, 0.5 A
LED for On/Ready for Run/Top Of Ramp
Green Green
Settings
Ramp time during start Ramp time during stop Initial- and End Voltage
1-10 sec. 0-20 sec. 40-70%
Above 40 °C up to max. 60 °C reduce the rated current with 0.8 % per °C.
1)
When used at high altitudes above 1000 meters up to 4000 meters you need to derate the rated current using the following formula.
2)
- 1000 ] [ % of Ie = 100 - x––––––– 150 x = actual altitude for the softstarter
UL ratings Softstarter Type
FLA A
Motor power P (hp) and full load current FLA (A) Ue Ue Ue 208 V 240 V 480 V hp hp hp
Ue 600V hp
Max. fuse
PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45
3.4 6.1 9 11 15.2 24.2 28 34 46.2
0.5 1 2 3 3 7.5 7.5 10 15
2 5 7.5 10 10 20 25 30 40
40 A J-Type 40 A J-Type 40 A J-Type 40 A J-Type 40 A J-Type 60 A J-Type 70 A J-Type 100 A J-Type 100 A J-Type
Low Voltage Products & Systems
0.75 1.5 2 3 5 7.5 10 10 15
2 3 5 7.5 10 15 20 25 30
A, Type
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
pe Ty
Softstarters
SS
Type PSS Overview
P
PSS18/30 ... PSS44/76
PSS50 ... PSS72/124
Softstarter, Type
Normal start: In Line connected 400 V kW A Rated current Ie,
PSS18/30 7.5 18
PSS30/52
PSS37/64
PSS44/76
PSS50/85
PSS60/105
PSS72/124
15 30
18.5 37
22 44
25 50
30 60
37 72
In Line connected 480 V hp Rated current Ie, A
10 18
20 28
25 34
30 40
30 47
40 56
50 67
T2S160
T2S160
T2S160
T2S160
T2S160
400V, 40 °C MCCB (50 kA), Type
If using MCCB only, type 1
T2S160
coordination will be achieved.
Fuse protection (65 kA) Bussmann, Type
To achieve a type 2 coordination, semi-condcutor fuses must be used.
170M1364
Suitable switch fuse for
OS160RD0380
recommended semi-conductor fuses.
The line contactor is not required for the softstarter itself but often used to open if OL trips.
T2S160
170M1366
170M1368
170M1369
170M1369
170M1370
170M1371
OS160RD0380
OS160RD0380
OS160RD0380
OS160RD0380
OS160RD0380
A40
A50
A50
A63
A75
TA42DU
TA75DU
TA75DU
TA75DU
TA75DU
A26
A26
A30
A40
A50
PSCT-60 1 turn
PSCT-75 1 turn
PSCT-75 1 turn
PSCT-75 1 turn
Switch fuse, Type OS160RD0380
Line contactor, Type A26
A30
Thermal overload relay, Type
The overload relay is always required to protect the motor.
TA25DU
TA25DU
By-pass contactor, Type
The by-pass contactor can be used to reduce the power loss of the softstarter but also to increase the number of starts/h. All softstarters be operated without by-pass. can
A9
Must be used if current limit function is required.
PSCT-60 2 turns
A16
Current transformers, Type PSCT-40 1 turn
PSCT-50 1 turn
The table above is an overview of possible combinations of devices. Complete coordination tables are available at www.abb.com/lowvoltage.
1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters Type PSS Overview
PSS85/147... PSS142/245
fts
ta r e P ters SS
Ty p
1
PSS175/300... PSS300/515
Softstarter, Type PSS85/147 45 85
PSS105/181 55 105
PSS142/245
PSS175/300
PSS250/430
PSS300/515
75 142
90 175
132 250
160 300
60 85
75 105
100 125
125 156
150 225
200 248
T3S250
T3S250
T4S320
T5S400
400V, 40 °C MCCB (50 kA), Type T2S160
T3S250
Fuse protection (65 kA) Bussmann, Type 170M1372
170M3019
170M3020
170M3021
170M5013
170M5015
OESA250R03D80
OESA250R03D80
OESA250R03D80
OESA400R03D80
OESA400R03D80
A145
A185
A50
A300
TA200DU
TA200DU
TA450DU
TA450DU
A95
A145
A145
A210
PSCT-200 1 turn
PSCT-250 1 turn
PSCT-400 1 turn
PSCT-75 1 turn
Switch fuse, Type OS160RD0380
Line contactor, Type A95
A110
Thermal overload relay, Type TA110DU
TA110DU
By-pass contactor, Type A50
A63
Current transformers, Type PSCT-125 1 turjfdn
PSCT-150 1 turn
How to select correct size By using the guide beside, you can quickly select a suitable softstarter for the most common applications. If a more precise selection is required, you can use Prosoft, a selection software . available at www.abb.com/lowvoltage.
Quick guide for selection Normal start Class 10
Heavy duty start Class 30
Ordering – See page 14 –15
Ordering – See page 16 –17
Typical applications
Typical applications
● Bow
●
●
●
●
thruster Compressor Elevator
●
! Low Voltage Products & Systems
Centrifugal pump Conveyor belt (short) Escalator
● ● ●
Centrifugal fan Crusher Mixer
● ● ●
Conveyor belt (long) Mill Stirrer
If more than 10 starts /h Select one size larger than the standard selection.
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
1
te ar
t
fts
So
pe Ty
Softstarters
SS
Type PSS18/30 ... PSS300/515 Application and Description
P
Application The softstarter range PSS18/30 ... PSS300/515 is a very flexible solution suitable for most applications and for replacements of Star-Delta starters. Since the unit can be connected inside the motor delta (compare the connection for standard Star-Delta starters), the current through the softstarter is reduced by 42 %. It will then be possible, for example, to run a 100 A motor using a 58 A PSS Softstarter.
In-Line
100 A
Inside Delta The PSS Softstarter can be selected according to the rated motor power in normal duty applications like pumps, compressors, elevators, escalators, short conveyor belts and bow thrusters – see page 14-15.
58 A 100 A
100 A
For heavy duty applications like centrifugal fans, crushers, mixers, mills, stirrers and long conveyor belts, select a softstarter from page 16-17.
In-Line and Inside Delta connection of PSS18/30 … PSS300/515
Description • Wide main voltage range 208 - 690 V AC • Supply voltage range 110-120 V AC and 220-240 V AC • Current ratings 18 ... 300 A (In Line) and 30 ... 515 A (Inside Delta) • Same unit can be used for both In Line and Inside Delta connection • Start ramp, Stop ramp and Initial voltage included • Current limit function as option • Solid state electrical circuit • Designed for continuous operation without by-pass • 15 % overcurrent capability during continuous run (10 % for PSS300/515) • Accessories for connection and installation available: See the ordering pages
Built-in signal relays for fault and by-pass Transparent lid to protect the settings
LED indications:
Power supply on
Completed start ramp
General fault (motor side or unit)
External fault
Three rotating switches setting: -Start ramp (1–30 sec) -Stop ramp (0–30 sec) -Initial voltage (30–70 % of Ue) -Current limit 1.5 –4 x Ir (If used: Initial voltage fixed at 40 % of Ue) Dip-switch for In Line/ Inside Delta connection
10 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
ta r e P ters SS
Ty p
1
(1SFC132186F0001)
Type PSS18/30 ... PSS300/515
Different sizes of PSS, from left PSS175/300-500L, PSS85/147-500L, PSS50/85-500L and in the front PSS18/30-500L.
Settings PSS18/30 … PSS300/515 U 1
2
3 U ini
3
time Start
Stop
1
2
1 Ramp time START = 1 ... 30 sec 2 Ramp time STOP = 0 ... 30 sec 3 Initial voltage U =40 ... 70 %, when current limit is ini
used fixed at 40 % (also set ”end voltage”)
Low Voltage Products & Systems
11
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
pe Ty
SS
P
Softstarters
Type PSS18/30 ... PSS300/515 Normal starts, class 10 – In-Line, Ordering details PSS18/30 ... PSS300/515 230 – 500 V
PSS18/30-500 ... 44/76-500
PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690
PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
7.5 15 18.5 22 25 30 37 45 55 75 90 132 160
11 18.5 22 25 30 37 45 55 75 90 110 160 200
- - - - - - - - - - - - -
18 30 37 44 50 60 72 85 105 142 175 250 300
400 – 690 V
Order code **)
PSS18/30-500n ■ PSS30/52-500n ■ PSS37/64-500n ■ PSS44/76-500n ■ PSS50/85-500n ■ PSS60/105-500n ■ PSS72/124-500n ■ PSS85/147-500n ■ PSS105/181-500n ■ PSS142/245-500n ■ PSS175/300-500n ■ PSS250/430-500n ■ PSS300/515-500n ■
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
7.5 15 18.5 22 25 30 37 45 55 75 90 132 160
11 18.5 22 25 30 37 45 55 75 90 110 160 200
15 25 30 37 45 55 59 75 90 132 160 220 257
18 30 37 44 50 60 72 85 105 142 175 250 300
1SFA 892 001 R▼00▼ 1SFA 892 002 R▼00▼ 1SFA 892 003 R▼00▼ 1SFA 892 004 R▼00▼ 1SFA 892 005 R▼00▼ 1SFA 892 006 R▼00▼ 1SFA 892 007 R▼00▼ 1SFA 892 008 R▼00▼ 1SFA 892 009 R▼00▼ 1SFA 892 010 R▼00▼ 1SFA 892 011 R▼00▼ 1SFA 892 013 R▼00▼ 1SFA 892 014 R▼00▼
Order code **)
PSS18/30-690■ ■ PSS30/52-690■ ■ PSS37/64-690■ ■ PSS44/76-690■ ■ PSS50/85-690 ■ ■ PSS60/105-690■ ■ PSS72/124-690■ ■ PSS85/147-690■ ■ PSS105/181-690■ ■ PSS142/245-690■ ■ PSS175/300-690■ ■ PSS250/430-690■ ■ PSS300/515-690■ ■
Supply voltage, Us
■ F = 110-120 V, 50/60 Hz
L = 220-240 V, 50/60 Hz
Fault signal relay
■ no code letter = NO
12 1SXU 132 019 C0202
C = NC
2.30 2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
Weight kg
1SFA 893 001 R▼00▼ 1SFA 893 002 R▼00▼ 1SFA 893 003 R▼00▼ 1SFA 893 004 R▼00▼ 1SFA 893 005 R▼00▼ 1SFA 893 006 R▼00▼ 1SFA 893 007 R▼00▼ 1SFA 893 008 R▼00▼ 1SFA 893 009 R▼00▼ 1SFA 893 010 R▼00▼ 1SFA 893 011 R▼00▼ 1SFA 893 013 R▼00▼ 1SFA 893 014 R▼00▼
s Add code letter in Type for:
*)
PSS175/300-500 ... 300/515-500 PSS175/300-690 ... 300/515-690
Weight kg
2.30 2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
s Add code number in Order code for:
**)
Supply voltage, Us
▼ 1 = 110-120 V, 50/60 Hz
2 = 220-240 V, 50/60 Hz
Fault signal relay
▼ 1 = NO
2 = NC
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PSS18/30 ... PSS300/515 Normal starts, class 10 – Inside Delta, Ordering details
fts
ta r e P ters SS
Ty p
1
PSS18/30 ... PSS300/515 230 – 500 V
PSS18/30-500 ... 44/76-500
PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690
PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
15 25 30 37 45 55 59 75 90 132 160 220 257
18.5 30 37 45 55 75 80 90 110 160 200 295 355
- - - - - - - - - - - - -
30 52 64 76 85 105 124 147 181 245 300 430 515
PSS18/30-500■ ■ PSS30/52-500■ ■ PSS37/64-500■ ■ PSS44/76-500■ ■ PSS50/85-500■ ■ PSS60/105-500■ ■ PSS72/124-500■ ■ PSS85/147-500■ ■ PSS105/181-500■ ■ PSS142/245-500■ ■ PSS175/300-500■ ■ PSS250/430-500■ ■ PSS300/515-500■ ■
400 – 690 V
Motor power
400 V Pe
690 V Pe
Rated motor current, Ie
500 V Pe
Order code **)
1SFA 892 001 R▼00▼ 1SFA 892 002 R▼00▼ 1SFA 892 003 R▼00▼ 1SFA 892 004 R▼00▼ 1SFA 892 005 R▼00▼ 1SFA 892 006 R▼00▼ 1SFA 892 007 R▼00▼ 1SFA 892 008 R▼00▼ 1SFA 892 009 R▼00▼ 1SFA 892 010 R▼00▼ 1SFA 892 011 R▼00▼ 1SFA 892 013 R▼00▼ 1SFA 892 014 R▼00▼
*)
kW
kW
kW
A
Type
Order code
18.5 30 37 45 55 75 80 90 110 160 200 295 355
25 45 55 59 75 90 110 132 160 220 257 400 500
30 52 64 76 85 105 124 147 181 245 300 430 515
PSS18/30-690■ ■ PSS30/52-690■ ■ PSS37/64-690■ ■ PSS44/76-690■ ■ PSS50/85-690■ ■ PSS60/105-690■ ■ PSS72/124-690■ ■ PSS85/147-690■ ■ PSS105/181-690■ ■ PSS142/245-690■ ■ PSS175/300-690■ ■ PSS250/430-690■ ■ PSS300/515-690■ ■
1SFA 893 001 R▼00▼ 1SFA 893 002 R▼00▼ 1SFA 893 003 R▼00▼ 1SFA 893 004 R▼00▼ 1SFA 893 005 R▼00▼ 1SFA 893 006 R▼00▼ 1SFA 893 007 R▼00▼ 1SFA 893 008 R▼00▼ 1SFA 893 009 R▼00▼ 1SFA 893 010 R▼00▼ 1SFA 893 011 R▼00▼ 1SFA 893 013 R▼00▼ 1SFA 893 014 R▼00▼
s Add code letter in Type for:
Supply voltage, Us
■ F = 110-120 V, 50/60 Hz
L = 220-240 V, 50/60 Hz
Fault signal relay
■ no code letter = NO
Low Voltage Products & Systems
C = NC
2.30 2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
Weight **)
15 25 30 37 45 55 59 75 90 132 160 220 257
*)
PSS175/300-500 ... 300/515-500 PSS175/300-690 ... 300/515-690
Weight kg
kg
2.30 2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
s Add code number in Order code for:
**)
Supply voltage, Us
▼ 1 = 110-120 V, 50/60 Hz
2 = 220-240 V, 50/60 Hz
Fault signal relay
▼ 1 = NO
2 = NC
13
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
pe Ty
SS
P
Softstarters
Type PSS30/52 ... PSS300/515 Heavy duty starts, class 30 – In-Line, Ordering details PSS30/52 ... PSS300/515 230 – 500 V
PSS30/52-500 ... 44/76-500
PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690
PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690
Heavy duty
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
7.5 15 18.5 22 25 30 37 45 55 75 90 132
11 18.5 22 25 30 37 45 55 75 90 110 160
- - - - - - - - - - - -
18 30 37 44 50 60 72 85 105 142 175 250
400 – 690 V
Order code **)
PSS30/52-500■ ■ PSS37/64-500■ ■ PSS44/76-500■ ■ PSS50/85-500■ ■ PSS60/105-500■ ■ PSS72/124-500■ ■ PSS85/147-500■ ■ PSS105/181-500■ ■ PSS142/245-500■ ■ PSS175/300-500■ ■ PSS250/430-500■ ■ PSS300/515-500■ ■
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
7.5 15 18.5 22 25 30 37 45 55 75 90 132
11 18.5 22 25 30 37 45 55 75 90 110 160
15 25 30 37 45 55 59 75 90 132 160 220
18 30 37 44 50 60 72 85 105 142 175 250
1SFA 892 002 R▼00▼ 1SFA 892 003 R▼00▼ 1SFA 892 004 R▼00▼ 1SFA 892 005 R▼00▼ 1SFA 892 006 R▼00▼ 1SFA 892 007 R▼00▼ 1SFA 892 008 R▼00▼ 1SFA 892 009 R▼00▼ 1SFA 892 010 R▼00▼ 1SFA 892 011 R▼00▼ 1SFA 892 013 R▼00▼ 1SFA 892 014 R▼00▼
Add code letter in Type for: Supply voltage, Us ■ F = 110-120 V, 50/60 Hz L = 220-240 V, 50/60 Hz
14 1SXU 132 019 C0202
Fault signal relay
■ no code letter = NO
C = NC
Weight kg
1SFA 893 002 R▼00▼ 1SFA 893 003 R▼00▼ 1SFA 893 004 R▼00▼ 1SFA 893 005 R▼00▼ 1SFA 893 006 R▼00▼ 1SFA 893 007 R▼00▼ 1SFA 893 008 R▼00▼ 1SFA 893 009 R▼00▼ 1SFA 893 010 R▼00▼ 1SFA 893 011 R▼00▼ 1SFA 893 013 R▼00▼ 1SFA 893 014 R▼00▼
s
PSS175/300-500 ... 300/515-500 PSS175/300-690 ... 300/515-690
2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
Order code **)
PSS30/52-690■ ■ PSS37/64-690■ ■ PSS44/76-690■ ■ PSS50/85-690■ ■ PSS60/105-690■ ■ PSS72/124-690■ ■ PSS85/147-690■ ■ PSS105/181-690■ ■ PSS142/245-690■ ■ PSS175/300-690■ ■ PSS250/430-690■ ■ PSS300/515-690■ ■ *)
Weight kg
2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
s Add code number in Order code for: Supply voltage, Us ▼ 1 = 110-120 V, 50/60 Hz 2 = 220-240 V, 50/60 Hz **)
Fault signal relay
▼ 1 = NO
2 = NC
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Ty p
fts
ta
r Type PSS30/52 ... PSS300/515 e P ters Heavy duty starts, class 30 – Inside Delta, Ordering details SS
1
PSS30/52 ... PSS300/515 230 – 500 V
PSS30/52-500 ... 44/76-500
PSS50/85-500 ...72/124-500 PSS18/30-690 ... 72/124-690
PSS85/147-500 ...142/245-500 PSS85/147-690 ...142/245-690
Heavy duty
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type *)
15 25 30 37 45 55 59 75 90 132 160 220
18.5 30 37 45 55 75 80 90 110 160 200 295
- - - - - - - - - - - -
30 52 64 76 85 105 124 147 181 245 300 430
PSS30/52-500■ ■ PSS37/64-500■ ■ PSS44/76-500■ ■ PSS50/85-500■ ■ PSS60/105-500■ ■ PSS72/124-500■ ■ PSS85/147-500■ ■ PSS105/181-500■ ■ PSS142/245-500■ ■ PSS175/300-500■ ■ PSS250/430-500■ ■ PSS300/515-500■ ■
400 – 690 V
Motor power
400 V Pe
690 V Pe
Rated motor current, Ie
500 V Pe
Order code **)
1SFA 892 002 R▼00▼ 1SFA 892 003 R▼00▼ 1SFA 892 004 R▼00▼ 1SFA 892 005 R▼00▼ 1SFA 892 006 R▼00▼ 1SFA 892 007 R▼00▼ 1SFA 892 008 R▼00▼ 1SFA 892 009 R▼00▼ 1SFA 892 010 R▼00▼ 1SFA 892 011 R▼00▼ 1SFA 892 013 R▼00▼ 1SFA 892 014 R▼00▼
*)
kW
kW
kW
A
Type
Order code
18.5 30 37 45 55 75 80 90 110 160 200 295
25 45 55 59 75 90 110 132 160 220 257 400
30 52 64 76 85 105 124 147 181 245 300 430
PSS30/52-690■ ■ PSS37/64-690■ ■ PSS44/76-690■ ■ PSS50/85-690■ ■ PSS60/105-690■ ■ PSS72/124-690■ ■ PSS85/147-690■ ■ PSS105/181-690■ ■ PSS142/245-690■ ■ PSS175/300-690■ ■ PSS250/430-690■ ■ PSS300/515-690■ ■
1SFA 893 002 R▼00▼ 1SFA 893 003 R▼00▼ 1SFA 893 004 R▼00▼ 1SFA 893 005 R▼00▼ 1SFA 893 006 R▼00▼ 1SFA 893 007 R▼00▼ 1SFA 893 008 R▼00▼ 1SFA 893 009 R▼00▼ 1SFA 893 010 R▼00▼ 1SFA 893 011 R▼00▼ 1SFA 893 013 R▼00▼ 1SFA 893 014 R▼00▼
s Add code letter in Type for: Supply voltage, Us ■ F = 110-120 V, 50/60 Hz L = 220-240 V, 50/60 Hz
Low Voltage Products & Systems
Fault signal relay
■ no code letter = NO C = NC
2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
Weight **)
15 25 30 37 45 55 59 75 90 132 160 220
*)
PSS175/300-500 ... 300/515-500 PSS175/300-690 ... 300/515-690
Weight kg
kg
2.30 2.30 2.30 3.60 3.80 3.80 8.60 10.40 10.40 20.50 22.00 22.00
s Add code number in Order code for: Supply voltage, Us ▼ 1 = 110-120 V, 50/60 Hz 2 = 220-240 V, 50/60 Hz **)
Fault signal relay
▼ 1 = NO
2 = NC
15
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
pe Ty
Softstarters
SS
Accessories for type PSS18/30 ... PSS300/515 Ordering details
P
Current transformer for current limit function To be connected to terminals 11 and 12 on the softstarter. The setting range (1.5 – 4) corresponds to a multiple of the transformer ratio.. Technical data below shows transformer ratio and number of turns for the primary winding. You can also use your own current transformer with corresponding transformer ratio and with minimum 1 VA.
PSCT..
For softstarter Transformer ratio, type Number of turns
Type
Order code
Weight kg Packing piece 1 piece
PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515
PSCT-60 PSCT-40 PSCT-50 PSCT-60 PSCT-75 PSCT-75 PSCT-100 PSCT-125 PSCT-150 PSCT-200 PSCT-250 PSCT-400 PSCT-400
1SFA 899 001 R1060 1SFA 899 001 R1040 1SFA 899 001 R1050 1SFA 899 001 R1060 1SFA 899 001 R1075 1SFA 899 001 R1075 1SFA 899 001 R1100 1SFA 899 001 R1125 1SFA 899 001 R1150 1SFA 899 001 R1200 1SFA 899 001 R1250 1SFA 899 001 R1400 1SFA 899 001 R1400
1 1 1 1 1 1 1 1 1 1 1 1 1
Type
Order code
Packing piece
60/1 – 2 turns 40/1 – 1 turn 50/1 – 1 turn 60/1 – 1 turn 75/1 – 1 turn 75/1 – 1 turn 100/1 – 1 turn 125/1 – 1 turn 150/1 – 1 turn 200/1 – 1 turn 250/1 – 1 turn 400/1 – 1 turn 400/1 – 1 turn
0.30 0.30 0.30 0.30 0.30 0.30 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Cable connectors for Cu cables For softstarter type
Wire range mm2
Tightening torque max. Nm
PSS85/147…142/245 6-185 16 PSS85/147…142/245 2x(50-120) 16 25 PSS175/300…300/515 16-240
– 1SDA 023 354 R0001 LZ185-2C/120 1SFN 074 709 R1000 – 1SDA 023 368 R0001
3 3 3
Weight kg 1 piece
0.20 0.30 0.40
Cable connectors for Al and Cu cables
For softstarter type
LZ...
Wire range mm2
PSS85/147…142/245 35-95 PSS85/147…142/245 25-150 PSS175/300…300/515 120-240
Tightening torque max. Nm
Type
Order code
Weight Packing kg piece 1 piece
13.5 31 43
– – –
1SDA 023 356 R0001 1SDA 023 357 R0001 1SDA 023 370 R0001
3 3 3
Type
Order code
Weight Packing kg piece 1 piece
PSLW-44
1SFA 899 002 R1044
1
0.10
0.10 0.10 0.10
Terminal enlargements PSLW-44
For softstarter type
Wire range mm2
PSS18/30-500 ...44/76-500 1x6...35 2x6...16
LW...
PSS50/85-500…72/124-500 PSS18/30-690 ... 72/124-690 1x10...50 2x10...25
PSLW-72
1SFA 899 002 R1072
1
0.15
PSS85/147…142/245
LW185
1SFN 074 707 R1000
1
0.25
PSS175/300…300/515
LW300
1SFN 075 107 R1000
1
0.40
Type
Order code
Weight Packing kg piece 1 piece
LE185 LE300
1SFN 074 716 R1000 1SFN 075 116 R1000
2 2
Suitable for
Type
Order code
Weight Packing kg piece 1 piece
Cable connectors Compression lugs Cable connectors Compression lugs
LT185-AC LT185-AL LT300-AC LT300-AL
1SFN 124 701 R1000 1SFN 124 703 R1000 1SFN 125 101 R1000 1SFN 125 103 R1000
2 2 2 2
Terminal nut washer For softstarter type
PSS85/147…142/245 PSS175/300…300/515
LE185
0.20 0.30
Terminal shrouds For softstarter type
LT ... -AC
16 1SXU 132 019 C0202
LT ... -AL
PSS85/147…142/245 PSS85/147…142/245 PSS175/300…300/515 PSS175/300…300/515
0.10 0.10 0.20 0.20
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PSS18/30 ... PSS300/515 Technical data
1
PSS18/30 ... PSS300/515
Rated insulation voltage, Ui
690 V
Rated operational voltage, Ue
208 – 690 V
Starting capacity 4 x Ie for 10 sec at max. rated current, Ie Number of starts per hour
30 3)
Overload capability Overload class
10
Service factor
115 %
Ambient temperature. During operation During storage
-25 to +60 °C 1) -40 to +70 °C
Maximum altitud 4)
4000 m
Degree of protection Main circuit Supply and control circuit
PSS18/30-500 ... 44/76-500
PSS18/30 ... 250/430
.
PSS300/515
110 %
.
PSS50/85-500 ...72/124-500
IP 20
IP 10 IP 10 PSS18/30-690 ... 72/124-690
PSS85/147-690 ...300/515-690.
IP 00
PSS18/30…PSS300/515
IP 20
Settings. Ramp time during start Ramp time during stop Initial voltage during start
1 – 30 sec 0 – 30 sec 30 – 70 %
1.5 ... 4 2)
Current limit function x CT-ratio
fts
ta r e P ters SS
Ty p
. .
Switch for. Inside Delta connection ON/OFF
Yes
Signal relays. By-pass signal Fault signal Rated operational voltage, Ue Rated thermal current, Ith Rated operational current, Ie at AC-15 (Ue=250 V)
Yes . . Yes (NO or NC) 250V 5A . . 1.5A
Signal indication LED. Ready to start/stand by ON Ramping up/down Completed start ramp T.O.R General fault External fault
Green. – Green. Red. Red
.
.
Above 40 °C, up to max 60 °C, reduce the rated current with 0.8 % per °C. Only if current transformer is connected (accessory). 3) Valid for 50 % on time and 50 % off time. 3.5 x Ie for 7 sec., if other data is required, contact your sales office. 4) When used at high altitudes above 1000 meters up to 4000 meters you need to derate rated current using the following formula. 1) 2)
x - 1000 . [ % of Ie = 100 - ––––––– ] 150 x = actual altitude for the softstarter
Low Voltage Products & Systems
17
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
pe Ty
SS
P
Softstarters
Type PSS18/30 ... PSS300/515 Technical data
Cross section of connection cables
Type of softstarter PSS 18/30-500 … 44/76-500
PSS50/85-500 … 72/124-500, 18/30-690 … 72/124-690
PSS85/147-500 … 142/245-500, 85/147-690 … 142/245-690
PSS175/300 … 300/515-500, 175/300 … 300/515-690
2.5 – 16 2.5 – 16
6 – 50 6 – 25
See accessories See accessories
See accessories. See accessories
2.6
4.5
See accessories
See accessories
Main circuit. Connection clamp
.
Solid/Stranded Solid/Stranded
Tightening torque (recommended) Nm
1 x mm2 2 x mm2
20
17.5
Connection bar
5
5
Width and thickness
mm
–
–
Hole diameter
mm
–
–
Tightening torque (recommended) Nm
–
–
9
1 x mm2 2 x mm2
2.5 –
2.5 –
2.5 –
2.5. –
Tightening torque (recommended) Nm
0.5
0.5
0.5
0.5
Supply and control circuit. Connection clamp. Solid/Stranded Solid/Stranded
E1858D
E1859D
ø 8.5
ø 10.2
18
Fuse ratings and power losses For Softstarter Type
Recommended ABB Overload protection Current range Type A
Max 2) power loss at rated /e W
Max fuse rating - main circuit 1) Bussman fuses A Type Holder
PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515
TA 25 DU TA 25 DU TA 42 DU TA 75 DU TA 75 DU TA 75 DU TA 75 DU TA 110 DU TA 110 DU TA 200 DU TA 200 DU TA 450 DU TA 450 DU
65 100 120 142 160 190 226 291 351 462 590 815 965
50 80 125 160 160 200 250 315 400 450 500 700 900
6–18 10–30 22–37 29–44 29–50 29–60 45–72 65–85 65–105 100–142 100–175 130–250 130–300
170M1364 170M1366 170M1368 170M1369 170M1369 170M1370 170M1371 170M1372 170M3019 170M3020 170M3021 170M5013 170M5015
170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H3004 170H3004 170H3004 170H3004 170H3004
Ferraz fuses circuit A Type 63 100 160 200 200 250 315 400 400 500 530 630 900
Power re- quirements of supply VA
6.6 URB 000 D08 V 0063 6.6 URB 000 D08 V 0100 6.6 URB 000 D08 V 0160 6.6 URD 30 D08 A 0200 6.6 URD 30 D08 A 0200 6.6 URD 30 D08 A 0250 6.6 URD 30 D08 A 0315 6.6 URD 30 D08 A 0400 6.6 URD 30 D08 A 0400 6.6 URD 30 D08 A 0500 6.6 URD 30 D08 A 0550 6.6 URD 31 D08 A 0630 6.6 URD 32 D11 A 0900
9. 9. 9. 9. 10. 10. 10. 36. 36. 36. 65 65 . 65
1)
For the supply circuit 6 A delayed, for MCB use C characteristics.. Calculated power loss at operational current (Iop) without by-pass.. Ptot = 3 x Iop + VA value. Example: PSS 60/105 running at 52A Ptot = 3 x 52 + 10 = 166W When using bypass, the powerloss is reduced to the VA value only. 2)
18 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
ta r e P ters SS
Ty p
Type PSS18/30 ... PSS300/515 UL ratings
1
3-phase motor rating - In Line Softstarters
Motor power P (hp) and nominal current Ie A
Ue 200V / 208V hp A
Ue 440V / 480V hp A
Type PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515
5 7.5 10 10 15 15 20 25 30 40 50 75 75
18 28 34 40 47 56 67 85 105 125 156 225 248
Ue 220V / 240V hp A 5 10 10 10 15 20 20 30 40 40 60 75 100
18 28 34 40 47 56 67 85 105 125 156 225 248
10 20 25 30 30 40 50 60 75 100 125 150 200
18 28 34 40 47 56 67 85 105 125 156 225 248
Ue 550V / 600V hp A 15 25 30 30 40 50 60 75 100 125 150 200 250
18 28 34 40 47 56 67 85 105 125 156 225 248
3-phase motor rating - Inside Delta Softstarters
Motor power P (hp) and nominal current Ie A
Ue 200V / 208V hp A
Ue 440V / 480V hp A
Type PSS18/30 PSS30/52 PSS37/64 PSS44/76 PSS50/85 PSS60/105 PSS72/124 PSS85/147 PSS105/181 PSS142/245 PSS175/300 PSS250/430 PSS300/515
7.5 15 20 20 25 30 40 50 60 75 75 125 150
Low Voltage Products & Systems
30 48 58 69 81 96 116 147 181 215 270 389 429
Ue 220V / 240V hp A 10 15 20 25 30 30 40 50 60 75 100 150 150
30 48 58 69 81 96 116 147 181 215 270 389 429
20 30 40 50 60 75 75 100 150 150 200 300 350
30 48 58 69 81 96 116 147 181 215 270 389 429
Ue 550V / 600V hp A 25 40 50 60 75 75 100 150 150 200 250 400 400
30 48 58 69 81 96 116 147 181 215 270 389 429
19
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
Softstarters
ST
Type PST30 ... 300 and PSTB370 ... 1050 Overview
eP
p Ty
PST85 ... PST142
PST30 ... PST72
Normal start: In Line connected (400 V) kW Rated current Ie, A In Line connected (480 V) hp Rated current Ie, A
Softstarter, Type PST30
PST37
PST44
PST50
PST60
PST72
PST85
PST105
PST142
15 30
18.5 37
22 44
25 50
30 60
37 72
45 85
55 105
75 142
20 28
25 34
30 42
40 54
40 60
50 68
60 80
75 104
100 130
T2S160
T2S160
T2S160
T2S160
T2S160
T3S250
T3S250
400V, 40 °C MCCB (50 kA), Type
If using MCCB only, type 1 coordination will be achieved.
T2S160
Fuse protection (65 kA) Bussmann, Type
T2S160
To achieve a type 2 coordination, semi-condcutor fuses must be used.
170M1366 170M1368 170M1369 170M1369 170M1370 170M1371 170M1372 170M1319 170M1320
Suitable switch fuse for recommended semi-conductor fuses.
OS160RD0380 OS160RD0380 OS160RD0380 OS160RD0380 OESA250R03D80 OS160RD0380 OS160RD0380 OS160RD0380 OESA250R03D80
Line contactor, Type
The line contactor is not required for the softstarter itself but often used to open if OL trips.
Switch fuse, Type
A30
A40
A50
Thermal overload relay, Type
The overload relay is always required to protect the motor.
Built-in
By-pass contactor, Type
The by-pass contactor can be used to reduce the power loss of the softstarter but also to increase the number of starts/h. All softstarters be operated without by-pass. can
A9
Integrated
Built-in
A16
Built-in
A26
A50
A63
A75
A95
A110
A145
Built-in
Built-in
Built-in
Built-in
Built-in
Built-in
A26
A30
A40
A50
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Current transformers Integrated
Integrated
The table above is an overview of possible combinations of devices. Complete coordination tables are available at www.abb.com/lowvoltage.
20 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Overview
PST175... PST300
PSTB370 ... 470
fts
ta r e P ters ST
Ty p
1
PSTB570 ... 1050
Softstarter, Type PST175
PST210
PST250
PST300
PSTB370
PSTB470
PSTB570
PSTB720
PSTB840
PSTB1050
90 175
110 210
132 250
160 300
200 370
250 470
315 570
400 720
450 840
560 1050
125 156
150 192
200 248
250 302
300 361
400 480
500 590
600 720
700 840
900 1062
T5S400
T5S400
T5S1630
T5S1630
S6S630
S6S800
S7S1250
S7S1600
170M5013
170M5015
170M5015
170M5018
170M5018
170M5020 2)
400V, 40 °C MCCB (50 kA), Type T4S250
T4S250
Fuse protection (65 kA) Bussmann, Type 170M3021
170M5012
170M5013
170M5015
Switch fuse, Type 1) OESA250R03D80 OESA400R03D80 OESA400R03D80 OESA630R03D80 OESA400R03D80 OESA400R03D80 OESA630R03D80 OESA800R03D80
1)
Line contactor, Type A185
A210
A260
A300
A400
A580
A580
A750
A1350
A1650
Built-in
Built-in
Built-in
Built-in
Built-in
Built-in
Built-in
A145
A210
Built-in
Built-in
Built-in
Built-in
Built-in
Built-in
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Integrated
Thermal overload relay, Type Built-in
Built-in
Built-in
By-pass contactor, Type A145
A145
Current transformers Integrated
Integrated
PSTB840 and PSTB1050: Switch fuse not available, use fuseholder, see page 40. 2) PST1050-690-70 has 170M6019 1)
Quick guide for selection
How to select correct size By using the guide beside, you can quickly select a suitable softstarter for the most common applications. If a more precise selection is required, you can use Prosoft, a selection software available at www.abb.com/lowvoltage.
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Normal start Class 10
Heavy duty start Class 30
Ordering – See page 26 –27
Ordering – See page 28 –29
Typical applications
Typical applications
●
●
● ●
Bow thruster ● Centrifugal pump Compressor ● Conveyor belt (short) Elevator ● Escalator
!
● ●
Centrifugal fan Crusher Mixer
● ● ●
Conveyor belt (long) Mill Stirrer
If more than 10 starts /h
Select one size larger than the standard selection.
21 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
Softstarters
ST
Type PST30 ... 300 and PSTB370 ... 1050 Application and description
eP
p Ty
Application
Description
The PST range is a microprocessor based softstarter designed with the latest technology for soft start and soft stop of motors. The PST Softstarter has several advanced motor protection features as standard. The four button keypad and the logic structure of the menu make the installation, commissioning and operation easy. It is possible to choose between 13 different languages.
• Wide main voltage range 208 - 690 V AC • Wide supply voltage range 100 – 250 V, 50/60 Hz • Current ratings 30 to 1050 A (In Line) and 52 ... 1810 A (Inside Delta) • Same unit can be used for both In Line and Inside Delta connection • Premium adjustable Softstarter functions like start/stop ramp, kick start, jog, step down voltage and sequential starts. • Current limit adjustable between 2–7 x Ie • Thermistor (PTC) supervision of motor winding • Real time clock • Logging of last 20 events with time marking • Prepared for fieldbus communication • Motor overload protection with simulated motor temperature from measured current. Select between 10A, 10, 20 and 30 • Locked rotor protection • Motor underload protection • Phase imbalance protection • Phase reversal protection • Torque control • Analog output
The PST Softstarter can be used with or without a by-pass contactor except for the larger sizes PSTB370 ... PSTB1050 where the by-pass contactor is already built-in. The PST Softstarter can be selected according to the rated motor power in normal duty applications like pumps, compressors, elevators, escalators, short conveyor belts and bow thrusters. See page 26-27 For heavy duty applications like centrifugal fans, crushers, mixers, mills, stirrers and long conveyor belts, select a softstarter from page 28-29.
In-Line
Inside Delta
100 A
58 A 100 A
100 A
In-Line and Inside Delta connection of PST30 … PSTB1050
Programmable signal inputs
Three separate terminals prepared for external by-pass
Programmable signal relays
LCD-display with plain words in your language
Four button keypad
Symbol for torque control
Integrated advanced motor protection LED indications:
Power on
Fault
Protection
Clear information Terminals for PTC input and analogue output
22 1SXU 132 019 C0202
Fieldbus communication
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Functional description LCD display
The display of the PST gives you information presented in plain words in required language. You can choose between 13 different languages including English, German, Italian, Chinese, Finnish, Swedish, French, Spanish, Dutch, Portuguese, Russian, Turkish and Polish. On the PST display, you get all the information you need to set up, adjust and trouble-shoot. This makes the PST extremely easy to handle and reduces the risk of misinterpretations.
Four button keypad
The PST employs the same basic user concept as today’s advanced mobile telephones. Using the four buttons on the keypad, you can easily adjust your own start and stop profile and motor protection functions for any type of application. There are standard settings for many common applications including pumps, conveyors, fans, mixers and compressors for quick and easy set up. You can also set the advanced warning parameters to allow potential problems to be identified before real problems occur. A password protection function is available to prevent unauthorized changes to the programming.
Starting several motors
You can store as many as three different starting parameter sets for optimal sequence start of three different motors. You can use this function for two or three speed motors as well.
Integrated advanced motor protection
Inside the PST Softstarter, you will find useful features for advanced motor and softstarter protection, including; programmable overload protection, high current, underload, phase imbalance, phase reversal, thyristor overload protection, and bypass monitoring to ensure proper by-pass operation
Programmable signal relays
All PST units have three programmable signal relays where each relay can signal Run, Top of Ramp or Event. The Event setting can be used to signal protections, faults and warnings. The supervisory functions monitor not only software and critical softstarter functionality but also phase loss and out of frequency range.
fts
ta r e P ters ST
Ty p
1
Fieldbus communication
The PST Softstarter has a built-in interface on the front for connection of the ABB FieldBusPlug used for fieldbus communication. Through this interface it is possible to control the softstarter, achieve status information, up- and down load of parameters. The interface between the softstarter and the FieldBusPlug is always the same. Independently of PST Softstarter size or delivery date it is possible to connect to any fieldbus protocol later on since this is defined in the FieldBusPlug itself. Avaliable protocols are AS-Interface, DeviceNet, Profibus DP and Modbus-RTU. To connect the PST Softstarter to a fieldbus system you need the accessories described on page 31 to 36 as well as specific software for PLC set-up, which is available at www.abb.com/lowvoltage on the Softstarter pages.
Torque control
The default setting is a normal voltage ramp but it is possible to select torque ramp. With the torque control function it is possible to start and stop motors with a more linear acceleration than when using the normal voltage ramps. During start this can be used to reduce the wear on the equipment driven by the motor. During stop, controlling the torque is especially useful for pump applications where voltage ramps can lead to a sudden torque drop which may result in water hammering and pressure surges. Torque control will keep these problems to an absolute minimum.
Torque limit
With the torque limit function enabled, the torque can never exceed a set value during start. This will minimize stress and wear on the equipment driven by the motor.
Analog output
With the PST(B) softstarter it is possible to have analog output signals to be used as input to a PLC or an analog meter. The output signals can be selected to be for instance the current of the motor, main voltage, active power or the temperature of the motor. The terminals used for analog output are also used for PTC protection, so only one of these functions can be used.
Integrated by-pass contactor
On the larger sizes (PSTB 370 ... PSTB1050), there is an ABB AF contactor integrated. This gives you advantages in terms of cost- saving, space saving and last but not least energy saving. With a by-pass contactor you can reduce the power losses during normal run by 90 % or more. The smaller units, PST30 up to PST300, which are not equipped with a built-in by-pass contactor, have an extra set of three terminals on the line side. The terminals are marked B1, B2 and B3 and shall be used when connecting an external by-pass contactor. This will enable the integrated protection functions also when the softstarter is by-passed.
External keypad (option)
An external keypad is available as option. The keypad can be mounted on a panel door for example to view/control the softstarter without opening the door. The keypad can also be used to copy parameters between different softstarters. PSTB570 with integrated by-pass contactor. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
23 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
ST
eP
p Ty
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Normal starts, class 10 – In-Line, Ordering details PST30 ... PST300 230 – 600 V
PST30 ... PST72
PST85 ... PST142
PST175 ... PST300
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power 400 V 500 V Pe Pe kW kW
690 V Pe kW
Rated motor current, Ie A Type
15 18.5 22 25 30 37 45 55 75 90 110 132 160
- - - - - - - - - - - - -
30 37 44 50 60 72 85 105 142 175 210 250 300
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
15 18.5 22 25 30 37 45 55 75 90 110 132 160
18.5 22 25 30 37 45 55 75 90 110 132 160 200
25 30 37 45 55 59 75 90 132 160 184 220 257
30 37 44 50 60 72 85 105 142 175 210 250 300
18.5 22 25 30 37 45 55 75 90 110 132 160 200
400 – 690 V
PST30-600-70 PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70
Order code
1SFA 894 002 R7000 1SFA 894 003 R7000 1SFA 894 004 R7000 1SFA 894 005 R7000 1SFA 894 006 R7000 1SFA 894 007 R7000 1SFA 894 008 R7000 1SFA 894 009 R7000 1SFA 894 010 R7000 1SFA 894 011 R7000 1SFA 894 012 R7000 1SFA 894 013 R7000 1SFA 894 014 R7000
Weight kg
4.8 4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
Supply voltage, Us 100...250 V, 50/60 Hz
PST30-690-70 PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70
Order code
1SFA 895 002 R7000 1SFA 895 003 R7000 1SFA 895 004 R7000 1SFA 895 005 R7000 1SFA 895 006 R7000 1SFA 895 007 R7000 1SFA 895 008 R7000 1SFA 895 009 R7000 1SFA 895 010 R7000 1SFA 895 011 R7000 1SFA 895 012 R7000 1SFA 895 013 R7000 1SFA 895 014 R7000
Weight kg
4.8 4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
PSTB370 ... PSTB1050 with integrated by-pass 230 – 600 V
PSTB370 ... PSTB470
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
200 250 315 400 450 560
257 315 400 500 600 730
- - - - - -
370 470 570 720 840 1050
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
200 250 315 400 450 560
257 315 400 500 600 730
355 450 560 710 800 1000
370 470 570 720 840 1050
400 – 690 V
PSTB570 ... PSTB1050
24 1SXU 132 019 C0202
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70
Order code
1SFA 894 015 R7000 1SFA 894 016 R7000 1SFA 894 017 R7000 1SFA 894 018 R7000 1SFA 894 019 R7000 1SFA 894 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
Supply voltage, Us 100...250 V, 50/60 Hz
PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70
Order code
1SFA 895 015 R7000 1SFA 895 016 R7000 1SFA 895 017 R7000 1SFA 895 018 R7000 1SFA 895 019 R7000 1SFA 895 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Normal starts, class 10 – Inside Delta, Ordering details
fts
ta r e P ters ST
Ty p
1
PST30 ... PST300 230 – 600 V
PST30 ... PST72
PST85 ... PST142
PST175 ... PST300
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie Type A
25 30 37 45 55 59 75 90 132 160 184 220 257
30 37 45 55 75 80 90 110 160 200 250 295 355
- - - - - - - - - - - - -
52 64 76 85 105 124 147 181 245 300 360 430 515
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
25 30 37 45 55 59 75 90 132 160 184 220 257
30 37 45 55 75 80 90 110 160 200 250 295 355
45 55 59 75 90 110 132 160 220 257 315 400 500
52 64 76 85 105 124 147 181 245 300 360 430 515
400 – 690 V
Supply voltage, Us 100...250 V, 50/60 Hz
PST30-600-70 PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70
Order code
1SFA 894 002 R7000 1SFA 894 003 R7000 1SFA 894 004 R7000 1SFA 894 005 R7000 1SFA 894 006 R7000 1SFA 894 007 R7000 1SFA 894 008 R7000 1SFA 894 009 R7000 1SFA 894 010 R7000 1SFA 894 011 R7000 1SFA 894 012 R7000 1SFA 894 013 R7000 1SFA 894 014 R7000
Weight kg
4.8 4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
Supply voltage, Us 100...250 V, 50/60 Hz
PST30-690-70 PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70
Order code
1SFA 895 002 R7000 1SFA 895 003 R7000 1SFA 895 004 R7000 1SFA 895 005 R7000 1SFA 895 006 R7000 1SFA 895 007 R7000 1SFA 895 008 R7000 1SFA 895 009 R7000 1SFA 895 010 R7000 1SFA 895 011 R7000 1SFA 895 012 R7000 1SFA 895 013 R7000 1SFA 895 014 R7000
Weight kg
4.8 4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
PSTB370...PSTB1050 with integrated by-pass 230 – 600 V
PSTB370 ... PSTB470
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
355 450 540 710 800 1000
450 600 700 880 1000 1250
- - - - - -
640 814 987 1247 1455 1810
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie Type A
355 450 540 710 800 1000
450 600 700 880 1000 1250
600 800 960 1200 1400 1700
640 814 987 1247 1455 1810
400 – 690 V
PSTB570 ... PSTB1050
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70
Order code
1SFA 894 015 R7000 1SFA 894 016 R7000 1SFA 894 017 R7000 1SFA 894 018 R7000 1SFA 894 019 R7000 1SFA 894 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
Supply voltage, Us 100...250 V, 50/60 Hz
PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70
Order code
1SFA 895 015 R7000 1SFA 895 016 R7000 1SFA 895 017 R7000 1SFA 895 018 R7000 1SFA 895 019 R7000 1SFA 895 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
25 1SXU 132 019 C0202
rs
1
te ar
t fts PST o S pe Ty
Softstarters
Type PST37 ... 300 and PSTB370 ... 1050 Heavy duty starts, class 30 – In-Line, Ordering details PST37 ... PST300 230 – 600 V
PST30 ... PST72
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
15 18.5 22 25 30 37 45 55 75 90 110 132
18.5 22 25 30 37 45 55 75 90 110 132 160
- - - - - - - - - - - -
30 37 44 50 60 72 85 105 142 175 210 250
PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70
Motor power
Supply voltage, Us 100...250 V, 50/60 Hz
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
15 18.5 22 25 30 37 45 55 75 90 110 132
18.5 22 25 30 37 45 55 75 90 110 132 160
25 30 37 45 55 59 75 90 132 160 184 220
30 37 44 50 60 72 85 105 142 175 210 250
400 – 690 V PST85 ... PST142
PST175 ... PST300
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70
Order code
1SFA 894 003 R7000 1SFA 894 004 R7000 1SFA 894 005 R7000 1SFA 894 006 R7000 1SFA 894 007 R7000 1SFA 894 008 R7000 1SFA 894 009 R7000 1SFA 894 010 R7000 1SFA 894 011 R7000 1SFA 894 012 R7000 1SFA 894 013 R7000 1SFA 894 014 R7000
Order code
1SFA 895 003 R7000 1SFA 895 004 R7000 1SFA 895 005 R7000 1SFA 895 006 R7000 1SFA 895 007 R7000 1SFA 895 008 R7000 1SFA 895 009 R7000 1SFA 895 010 R7000 1SFA 895 011 R7000 1SFA 895 012 R7000 1SFA 895 013 R7000 1SFA 895 014 R7000
Heavy duty Weight kg
4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
Weight kg
4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
PSTB370 ... PSTB1050 with integrated by-pass 230 – 600 V
PSTB370 ... PSTB470
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
160 200 250 315 400 450
200 257 315 400 500 600
- - - - - -
300 370 470 570 720 840
Motor power
400 V Pe kW
500 V Pe kW
690 V Pe kW
Rated motor current, Ie A Type
160 200 250 315 400 450
200 257 315 400 500 600
257 355 450 560 710 800
300 370 470 570 720 840
400 – 690 V
PSTB570...PSTB1050
26 1SXU 132 019 C0202
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70
Order code
1SFA 894 015 R7000 1SFA 894 016 R7000 1SFA 894 017 R7000 1SFA 894 018 R7000 1SFA 894 019 R7000 1SFA 894 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
Supply voltage, Us 100...250 V, 50/60 Hz
PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70
Order code
1SFA 895 015 R7000 1SFA 895 016 R7000 1SFA 895 017 R7000 1SFA 895 018 R7000 1SFA 895 019 R7000 1SFA 895 020 R7000
Weight kg
31.0 31.0 52.0 55.0 60.0 60.0 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
Ty p
fts
ta
r Type PST37 ... 300 and PSTB370 ... 1050 e P ters Heavy duty starts, class 30 – Inside Delta, Ordering details ST
1
PST37 ... PST300 230 – 600 V
PST30 ... PST72
400 V Pe kW
500 V Pe kW
690 V Rated motor Pe current, Ie kW A Type
25 30 37 45 55 59 75 90 132 160 184 220
30 37 45 55 75 80 90 110 160 200 250 295
- - - - - - - - - - - -
52 64 76 85 105 124 147 181 245 300 360 430
Motor power
400 V Pe kW
500 V Pe kW
690 V Rated motor Pe current, Ie Type kW A
25 30 37 45 55 59 75 90 132 160 184 220
30 37 45 55 75 80 90 110 160 200 250 295
45 55 59 75 90 110 132 160 220 257 315 400
400 – 690 V PST85 ... PST142
PST175 ... PST300
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PST37-600-70 PST44-600-70 PST50-600-70 PST60-600-70 PST72-600-70 PST85-600-70 PST105-600-70 PST142-600-70 PST175-600-70 PST210-600-70 PST250-600-70 PST300-600-70
Order code
1SFA 894 003 R7000 1SFA 894 004 R7000 1SFA 894 005 R7000 1SFA 894 006 R7000 1SFA 894 007 R7000 1SFA 894 008 R7000 1SFA 894 009 R7000 1SFA 894 010 R7000 1SFA 894 011 R7000 1SFA 894 012 R7000 1SFA 894 013 R7000 1SFA 894 014 R7000
Heavy duty Weight kg
4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
Supply voltage, Us 100...250 V, 50/60 Hz
52 64 76 90 105 124 147 181 245 300 360 430
PST37-690-70 PST44-690-70 PST50-690-70 PST60-690-70 PST72-690-70 PST85-690-70 PST105-690-70 PST142-690-70 PST175-690-70 PST210-690-70 PST250-690-70 PST300-690-70
Order code
1SFA 895 003 R7000 1SFA 895 004 R7000 1SFA 895 005 R7000 1SFA 895 006 R7000 1SFA 895 007 R7000 1SFA 895 008 R7000 1SFA 895 009 R7000 1SFA 895 010 R7000 1SFA 895 011 R7000 1SFA 895 012 R7000 1SFA 895 013 R7000 1SFA 895 014 R7000
Weight kg
4.8 4.8 4.8 5.0 5.0 11.2 13.0 13.0 21.5 21.5 23.0 23.0
PSTB370...PSTB1050 with integrated by-pass 230 – 600 V
PSTB370 ... PSTB470
400 V Pe kW
500 V Pe kW
690 V Rated motor Pe current, Ie Type kW A
257 355 450 540 710 800
355 450 600 700 880 1000
- - - - - -
515 640 814 987 1247 1455
Motor power
400 V Pe
500 V Pe
690 V Rated motor Pe current, Ie
kW
kW
kW
A
Type
Order code
257 355 450 540 710 800
355 450 600 700 880 1000
500 600 800 960 1200 1400
515 640 814 987 1247 1455
PSTB370-690-70 PSTB470-690-70 PSTB570-690-70 PSTB720-690-70 PSTB840-690-70 PSTB1050-690-70
1SFA 895 015 R7000 1SFA 895 016 R7000 1SFA 895 017 R7000 1SFA 895 018 R7000 1SFA 895 019 R7000 1SFA 895 020 R7000
400 – 690 V
PSTB570 ... PSTB1050 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Supply voltage, Us 100...250 V, 50/60 Hz
Motor power
PSTB370-600-70 PSTB470-600-70 PSTB570-600-70 PSTB720-600-70 PSTB840-600-70 PSTB1050-600-70
Order code
1SFA 894 015 R7000 1SFA 894 016 R7000 1SFA 894 017 R7000 1SFA 894 018 R7000 1SFA 894 019 R7000 1SFA 894 020 R7000
Weight kg,
31.0 31.0 52.0 55.0 60.0 60.0
Supply voltage, Us 100...250 V, 50/60 Hz Weight kg
31.0 31.0 52.0 55.0 60.0 60.0
27 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
Softstarters
ST
Accessories for type PST30 ... 300 and PSTB370 ... 1050 Ordering details
eP
p Ty
Cable connectors for Cu cables For PST85...300 you need 9 pieces if also using the terminals B1, B2, B3 for external by-pass contactor. For softstarter type
Wire range mm2
Tightening torque max. Nm
PST85 …142 PST85 …142 PST175 …300
6-185 16 2 x (50-120) 16 25 16-240
Type
Order code
Packing piece
– 1SDA 023 354 R0001 LZ185-2C/120 1SFN 074 709 R1000 – 1SDA 023 368 R0001
Weight kg 1 piece
3 3 3
0.20 0.30 0.40
Cable connectors for Al and Cu cables
LZ...
For PST85...300 you need 9 pieces if also using the terminals B1, B2, B3 for external by-pass contactor. For softstarter type
Wire range mm2
Tightening torque max. Nm
Type
Order code
Weight Packing kg piece 1 piece
PST85 …142 PST85 …142 PST175 …300
35-95 25-150 120-240
13.5 31 43
– – –
1SDA 023 356 R0001 1SDA 023 357 R0001 1SDA 023 370 R0001
3 3 3
Terminal extensions
LX...
0.10 0.10 0.10
For softstarter type
Dimensions hole ø bar mm2 mm
Type
Order code
Weight Packing kg pieces 1 piece
PST85…142 PST175…300 PSTB370...470 PSTB570...1050
8.5 10.5 10.5 13
LX185 LX300 LX460 LX750
1SFN 074 710 R1000 1SFN 075 110 R1000 1SFN 075 710 R1000 1SFN 076 110 R1000
1 1 1 1
17.5 x 5 20 x 5 25 x 5 40 x 6
0.250 0.350 0.500 0.850
Terminal enlargements
LW...
For softstarter type
Dimensions hole ø bar mm2 mm
Type
Order code
Weight Packing kg pieces 1 piece
PST30…72 PST85…142 PST175...300 PSTB370...470 PSTB570...1050
6.5 10.5 10.5 10.5 13
15 x 3 17.5 x 5 20 x 5 25 x 5 40 x 6
LW110 LW185 LW300 LW460 LW750
1SFN 074 307 R1000 1SFN 074 707 R1000 1SFN 075 107 R1000 1SFN 075 707 R1000 1SFN 076 107 R1000
1 1 1 1 1
0.100 0.250 0.450 0.730 1.230
Terminal nut washer
LE185
For softstarter type
Type
Order code
Weight Packing kg piece 1 piece
PST85...142 PST175...300
LE185 LE300
1SFN 074 716 R1000 1SFN 075 116 R1000
2 2
Type
Order code
Weight Packing kg pieces 1 piece
LT185-AC LT460-AC LT185-AL LT460-AL LT300-AC LT300-AL LT460-AC LT460-AL LT750-AC LT750-AL
1SFN 124 701 R1000 1SFN 125 701 R1000 1SFN 124 703 R1000 1SFN 125 703 R1000 1SFN 125 101 R1000 1SFN 125 103 R1000 1SFN 125 701 R1000 1SFN 125 703 R1000 1SFN 126 101 R1000 1SFN 126 103 R1000
2 2 2 2 2 2 2 2 2 2
Type
Order code
Weight Packing kg piece 1 piece
0.20 0.30
Terminal shrouds
LT ... -AC
LT ... -AL
For softstarter type
Req. qty
PST85…142 PST85…142 PST175...300 PST175...300 PSTB370...470 PSTB370...470 PSTB570...1050 PSTB570...1050
1 pcs and 1 pcs 1 pcs and 1 pcs 3 pcs 3 pcs 2 pcs 2 pcs 2 pcs 2 pcs
0.050 0.100 0.220 0.800 0.070 0.280 0.100 0.800 0.120 0.825
External keypad including a 3m cable PSTEK
For softstarter type
PST30...300 PSTB370...1050
PSTEK
1SFA 899 003 R1000
1
For softstarter type
Type
Order code
Weight Packing kg piece 1 piece
PST85…142
PSTM-2
1SFA 899 004 R1000
1
0.400
Marine Kit PSTM-2
28 1SXU 132 019 C0202
0.24
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
FBP FieldBusPlug AS-Interface Fieldbus Connectors
fts
Orange cable
ta
rte
1
rs
AS-Interface FieldBusPlug Direct
Ready-made AS-Interface slave fieldbus interface with various cable lengths. • Applicable on all MSD11-FBP and terminal devices with max. 2 input and 1 output signals. • Degree of protection IP65, diagnostic LED Designation Cable Packing FieldBusPlug length Type Order code pieces AS-Interafce FBP Direct AS-Interafce FBP Direct AS-Interafce FBP Direct AS-Interafce FBP Direct
0.25 m 0.50 m 1.00 m 5.00 m
ASD11-FBP.025 ASD11-FBP.050 ASD11-FBP.100 ASD11-FBP.500
1SAJ 210 000 R0003 1SAJ 210 000 R0005 1SAJ 210 000 R0010 1SAJ 210 000 R0050
1 1 1 1
Weight kg
1 piece 0.09 0.10 0.13 0.36
AS-Interface FieldBusPlug Performance
Ready-made AS-Interface slave fieldbus interface with various cable lengths. • Applicable on all FBP motor starters and devices with max. 4 input signals and 3 output signals • Degree of protection IP65, diagnostic LED ASD11-FBP ASP22-FBP
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Designation Cable Packing FieldBusPlug length Type Order code pieces
Weight kg
AS-Interafce FBP Performance
0.25 m
ASP22-FBP.025
1SAJ 220 000 R0003
1
1 piece 0.09
AS-Interafce FBP Performance
0.50 m
ASP22-FBP.050
1SAJ 220 000 R0005
1
0.10
AS-Interafce FBP Performance
1.00 m
ASP22-FBP.100
1SAJ 220 000 R0010
1
0.13
AS-Interafce FBP Performance
5.00 m
ASP22-FBP.500
1SAJ 220 000 R0050
1
0.36
29 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
Softstarters
FBP FieldBusPlug AS-Interface Fieldbus Accessories
Orange cable
Accessories for AS-Interface Bus Connection
AS-Interface Round Cable for Bus Junctions Ready-made bus cable with an M12 connector and an open cable end. • Application on bus junctions such as e.g. AS-Interface couplers or devices with an integrated AS-Interface Cable Packing Designation length Type Order code pieces
AS-Interface Round Cable with female connector 0.30 m ASF11-FBP.030 AS-Interface Round Cable with male connector 0.30 m ASM11-FBP.030
Weight kg
1 piece
1SAJ 922 002 R0003
1
0.04
1SAJ 922 003 R0003
1
0.04
ASF11-FBP, ASM11-FBP
AS-Interface Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors Cable Packing Designation length Type Order code pieces AS-Interface Extension Cable
ASX11-FBP
AS-Interface Extension Cable AS-Interface Extension Cable AS-Interface Extension Cable
Weight kg 1 piece
1.00 m
ASX11-FBP.100
1SAJ 922 001 R0010
1
0.08
3.00 m
ASX11-FBP.300
1SAJ 922 001 R0030
1
0.20
5.00 m
ASX11-FBP.500
1SAJ 922 001 R0050
1
0.31
100 m
ASC11-FBP.999
1SAJ 922 004 R1000
1
5.60
AS-Interface Round Cable and Accessories for Bus Extension Bus cable and coupling accessories Packing Designation Type Order code pieces
ASM11-FBP.0, ASF11-FBP.0
AS-Interface Round Cable, male conn. AS-Interface Round Cable, female conn. AS-Interface Flat-Cable Branch Circuit with M12 socket
Weight kg 1 piece
ASM11-FBP.0
1SAJ 922 005 R0001
5
ASF11-FBP.0
1SAJ 922 006 R0001
5
0.15
AST11-FBP.0
1SAJ 922 007 R0001
1
0.15
0.15
AS-Interface Addressing Device, Power Unit, miscellaneous accessories Designation Packing FieldBusPlug Type Order code pieces
AST11-FBP.0
30 1SXU 132 019 C0202
AS-Interface Addr. Device, including plug-in power unit Address Signs for FieldBusPlug
ASA21-FBP.0 CAL11-FBP.0
1SAJ 922 010 R0001 1SAJ 929 005 R0001
1 400
Weight kg 1 piece
0.56 0.15
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
FBP FieldBusPlug/DeviceNet and MODBUS-RTU Fieldbus Connectors
fts
Black cable
ta
rte
1
rs
DeviceNet FieldBusPlug Ready-made DeviceNet fieldbus interface with various cable lengths. • Applicable on all FBP motor starters and other devices • Degree of protection IP65, diagnostic LED Cable Packing Designation length Type Order code pieces
DeviceNet-FBP DeviceNet-FBP DeviceNet-FBP DeviceNet-FBP
0.25 m 0.50 m 1.00 m 5.00 m
DNP21-FBP.025 DNP21-FBP.050 DNP21-FBP.100 DNP21-FBP.500
1SAJ 230 000 R0003 1SAJ 230 000 R0005 1SAJ 230 000 R0010 1SAJ 230 000 R0050
1 1 1 1
Weight kg 1 piece
0.09 0.10 0.13 0.36
MODBUS-RTU FieldBusPlug Ready-made MODBUS-RTU fieldbus interface with various cable lengths. • Applicable on all FBP motor starters and other devices • Degree of protection IP65, diagnostic LED Cable Packing Designation length Type Order code pieces DNP21-FBP MRP21-FBP
MODBUS-RTU-FBP MODBUS-RTU-FBP MODBUS-RTU-FBP MODBUS-RTU-FBP
0.25 m 0.50 m 1.00 m 5.00 m
MRP21-FBP.025 MRP21-FBP.050 MRP21-FBP.100 MRP21-FBP.500
1SAJ 250 000 R0003 1SAJ 250 000 R0005 1SAJ 250 000 R0010 1SAJ 250 000 R0050
1 1 1 1
Weight kg 1 piece
0.09 0.10 0.13 0.36
To connect the PST Softstarter to a DeviceNet fieldbus system... you need specific software for PLC set-up, (EDS file) which is available at www.abb.com/lowvoltage on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
31 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
Softstarters
Black cable
FBP FieldBusPlug/DeviceNet and MODBUS-RTU Fieldbus Accessories
Accessories for the DeviceNet and MODBUS-RTU Bus Connector DeviceNet and MODBUS-RTU round cable for bus junctions Ready-made bus cable with an M12 connector and an open cable end.
Cable Packing Designation length Type Order code pieces
Round Cable with female connector 0.50 m Round Cable with male connector 0.50 m
Weight kg 1 piece
DNF11-FBP.050
1SAJ 923 002 R0005
1
0.04
DNM11-FBP.050
1SAJ 923 003 R0005
1
0.04
DNF-11FBP.050
DeviceNet and MODBUS-RTU Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors
Cable Packing Designation length Type Order code pieces DNM-11FBP.050
DNX11-FDP
Extension Cable Extension Cable
1.00 m
DNX11-FBP.100
1SAJ 923 001 R0010
1
0.08
3.00 m
DNX11-FBP.300
1SAJ 923 001 R0030
1
0.20
Extension Cable
5.00 m
DNX11-FBP.500
1SAJ 923 001 R0050
1
0.31
Round Cable
100 m
DNC11-FBP.999
1SAJ 923 004 R0001
1
5.6
DeviceNet and MODBUS-RTU Round Cable and Accessories for Bus Extension Bus cable and coupling accessories
Cable Packing Designation length Type Order code pieces
DNM11-FBP.0
Round Cable Male Connector DNM11-FBP.0 1SAJ 923 005 R0001 Device Net Round Cable Female Connector DNF11-FBP.0 1SAJ 923 006 R0001
0.15
5
0.15
Packing Designation Type Order code pieces
Termination Resistor, 120 Ohm
DNR11-FBP.120
1SAJ 923 007 R0001
Weight kg 1 piece
5
DeviceNet and MODBUS-RTU, Termination Resistor, Miscellaneous Accessories DNF11-FBP.0
Weight kg 1 piece
1
Weight kg 1 piece
0.02
DNR11-FBP.120
To connect the PST Softstarter to a DeviceNet fieldbus system... you need specific software for PLC set-up, (EDS file) which is available at www.abb.com/lowvoltage on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. 32 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Softstarters
Purple cable
FBP FieldBusPlug/Profibus DP/V0, DP/V1 Fieldbus Connectors
So
fts
ta
rte
1
rs
Profibus DP/V0 FieldBusPlug Ready-made Profibus DP/V0 fieldbus interface with various cable lengths. • Applicable on all FBP motor starters and other devices • Degree of protection IP65, diagnostic LED Cable Packing Designation length Type Order code pieces
Profibus DP/V0-FBP Profibus DP/V0-FBP Profibus DP/V0-FBP Profibus DP/V0-FBP
0.25 m 0.50 m 1.00 m 5.00 m
PDP21-FBP.025 PDP21-FBP.050 PDP21-FBP.100 PDP21-FBP.500
1SAJ 240 000 R0003 1SAJ 240 000 R0005 1SAJ 240 000 R0010 1SAJ 240 000 R0050
1 1 1 1
Weight kg 1 piece
0.09 0.10 0.13 0.36
Profibus DP/V1 FieldBusPlug Ready-made Profibus DP/V1 fieldbus interface with various cable lengths. • Applicable on all FBP motor starters and other devices • Degree of protection IP65, diagnostic LED
PDP21-FBP PDP22-FBP
Cable Packing Designation length Type Order code pieces
Profibus DP/V1-FBP Profibus DP/V1-FBP Profibus DP/V1-FBP Profibus DP/V1-FBP
0.25 m 0.50 m 1.00 m 5.00 m
PDP22-FBP.025 PDP22-FBP.050 PDP22-FBP.100 PDP22-FBP.500
1SAJ 240 100 R0003 1SAJ 240 100 R0005 1SAJ 240 100 R0010 1SAJ 240 100 R0050
1 1 1 1
Weight kg 1 piece
0.09 0.10 0.13 0.36
To connect the PST Softstarter to a Profibus DP fieldbus system... you need specific software for PLC set-up, (GSD file) which is available at www.abb.com/lowvoltage on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
33 1SXU 132 019 C0202
rs
1
te ar
t
ts of
S
Softstarters
FBP FieldBusPlug/Profibus DP/V0, DP/V1 Fieldbus Accessories
Purple cable
Accessories for the Profibus DP/V0. DP/V1 Bus Connector Profibus DP/V0, DP/V1 Round Cable for Bus Junctions Ready-made bus cable with an M12 connector and an open cable end. • Application on bus junctions such as e.g.Profibus DB couplers or devices with an integrated Profibus DB interface Cable Packing Designation length Type Order code pieces
PDF11-FBP.50
Weight kg 1 piece
Round Cable with female connector
0.50 m
PDF11-FBP.050
1SAJ 924 002 R0005
1
0.04
Round Cable with male connector
0.50 m
PDM11-FBP.050
1SAJ 924 003 R0005
1
0.04
Profibus DP/V0, DP/V1 Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors Cable Packing Designation length Type Order code pieces
PDM11-FBP.50
Weight kg 1 piece
Extension Cable Extension Cable
1.00 m
PDX11-FBP.100
1SAJ 924 001 R0010
1
0.08
3.00 m
PDX11-FBP.300
1SAJ 924 001 R0030
1
0.20
Extension Cable
5.00 m
PDX11-FBP.500
1SAJ 924 001 R0050
1
0.31
Round Cable
100 m
PDC11-FBP.999
1SAJ 924 004 R1000
1
5.60
Profibus DP/V0, DP/V1 Accessories for Bus Extension Packing Designation Type Order code pieces
Male Connector Female Connector
Weight kg 1 piece
PDM11-FBP.0
1SAJ 924 005 R0001
5
0.03
PDF11-FBP.0
1SAJ 924 006 R0001
5
0.03
PDX11-FBP
Profibus DP/V0, DP/V1 Termination Resistor, Miscellaneous Accessories Packing Designation Type Order code pieces
PDM11-FBP.0
Termination resistor, 150 ohm PDR11-FBP.150 1SAJ 924 007 R0001 1 Feeding connector 24V DC PDV11-FBP.0 1SAJ 924 008 R0001 1 Code B-A Feeding connector 24V DC PDV12-FBP.0 1SAJ 924 011 R0001 1 Code A-A Adaptor M12-Dsub9-M12 PDA11-FBP.050 1SAJ 924 009 R0001 1 Cable lenth 0.50m Adaptor M12-Dsub9-M12 PDA12-FBP.050 1SAJ 924 010 R0001 1 Cable lenth 2 x 0.50m
Weight kg 1 piece
0.03 0,04 0,04 0,04 0,04
PDF11-FBP.0
To connect the PST Softstarter to a Profibus DP fieldbus system... you need specific software for PLC set-up, (GSD file) which is available at www.abb.com/lowvoltage on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. 34 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PST30 ... 300 and PSTB370 ... 1050 Technical data
PST30 … 300
PSTB370 ... 1050
Rated insulation voltage Ui
690 V
690 V
Rated operational voltage Ue
208 ... 690 V
208 ... 690 V
Starting capacity at max rated current Ir
3 x Ir for 15 sec. 3 x Ir for 15 sec
Control circuit /Hardware inputs Internal 24 V DC (10 mA closed) Yes Start / Stop inputs Yes Two extra programmable inputs
Number of starts per hour
30 1)
Overload capability, Overload Class Service factor
10 115 %
10 1)
10 115 % (PSTB370... PSTB840) 100 % (PSTB1050) Ambient temperature During operation ±0 … +50 °C 2) ±0 … +50 °C 2) During storage -25… +70 °C -25… +70 °C Altitude Maximum altitude
4000 m 3)
4000 m
3)
Degree of protection Main circuit IP10 (PST30 ... 72) IP00 (all) IP00 ( PST85 ... 300) Supply and Control circuit IP20 IP20 Main circuit Built in By-pass contactor Cooling system - Fan cooled (thermostat controlled)
No
Yes
Yes
Yes
Supply circuit Supply voltage – one range
100 ... 250 V, 50/60 Hz +10 %/-15 %
100 ... 250 V 50/60 Hz +10 %/-15 %
Yes
Yes
Yes
Yes
HMI for settings (Human Machine Interface) 20 segment display Keypad with two selection keys and two navigating keys Plain text in 13 languages (English, German, Italian, Dutch, Chinese, Finnish, Swedish, French, Spanish, Russian, Portuguese, Turkish and Polish) Signal relays Number of programmable signal relays (Each relay can be programmed to be Run, By-pass or Event signal) K4 – Default as Run signal K5 – Default as By-pass signal K6 – Default as Event signal Rated operational voltage Ue Rated thermal current Ith Rated operational current Ie at AC-15 (Ue = 250 V) Analog output Output signal reference Type of output signal
Yes
3 Yes Yes Yes 250 V 5A
1.5 A
1.5 A
1
rs
PSTB370 ... 1050
Yes Yes
(Each input can be programmed to be either; Non, Reset, Enable, Jog, DOL- On, Start motor 2 or Start motor 3, FB-Dis ).
Yes
Yes
Signal indication LED’s Power on – Green Fault - Red Protection - Yellow
Yes Yes Yes
Yes Yes Yes
Yes
Yes
Yes
Yes
Yes Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes Yes Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Start of several motors Possible to set up and start three different motors
Yes
Yes
Field bus connection Connection for ABB FieldBusPlug
Yes
Yes
Protections Electronic overload Adjustable tripping classes Class 10 A, 10, 20 and 30 Dual overload (separate overload function for start and run) PTC connection Locked rotor protection Underload protection Phase imbalance High current (8 x Ie) Phase reversal protection Warnings (pre-warning) High current Low current (underload) Overload trip Overtemp. thyristors (SCR)
rte
PTC input Switch off resistance 2825 ohm + 20% 2825 ohm + 20% 1200 ohm + 20% 1200 ohm + 20% Switch on resistance
Yes
3 Yes Yes Yes 250 V 5 A
PST30 … 300
ta
External keypad Display LCD type Ambient temperature During operation + 0…+50 oC During storage -25…+70 oC Degree of protection IP66 1) Valid for 50 % on time and 50 % off time, with 3.5 x Ie for 7 seconds. If other data is required, please contact your sales office
Above 40 ºC up to max. 50 ºC reduce the rated current with 0.8 % per ºC.
2)
When used at high altitudes above 1000 meters up to 4000 meters you need to derate rated current using the following formula.
3)
0 ... 10 V, 0 ...20 mA, 4 ... 20 mA I Amp, U Volt, P kW, P hp, Q kVAr, S kVA, TmpMot, TmpSCR, cosPhi
x - 1000 [ % of Ie = 100 - ––––––– ] 150 x = actual altitude for the softstarter
PSTB Integrated by-pass ratings Softstarter
Type
PSTB370
PSTB470
PSTB570
PSTB720
PSTB840
PSTB1050
Contactor AC-3 rating
Type A
AF300 305
AF300 305
AF460 460
AF580 580
AF750 750
AF750 750
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
35 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Technical data/Settings
Major possible settings and the displayed text and the set default values Description
Text on display Values on display (Eng)
Default value
Setting current for overload, locked rotor etc. Time for start ramp Time for stop ramp Initial voltage for start ramp End voltage for stop ramp Step down voltage Level of the current limit. Selection of Kick start Level of Kick start if selected Time for Kick start if selected
Setting Ie Start Ramp Stop Ramp Init Volt End Volt Step Down Current Lim Kick Start Kick Level Kick Time
9,0 ...1207 A divided into 19 overlapping ranges. 1 ... 30 s, 1 ... 120 s (Range depends on Start Range) 0 ... 30 s, 0 ... 120 s (Range depends on Stop Range) 30 ... 70 % 30 ... 70 % 30 ...100 % 2.0 ... 7.0 x Ie Yes, No 50 ... 100 % 0.1 ... 1.5 s
See table, page 40 10 s 0s 30 % 30 % 100 % 4.0 x Ie No 50 % 0.2
Selectable range for start ramp Selectable range for stop ramp Overload protection Overload Class Overload Class, Dual type, Start Class Overload Class, Dual type, Run Class Type of operation for overload protection Locked rotor protection Trip level for locked rotor protection Trip time for locked rotor protection Type of operation for locked rotor protection Underload protection Trip level for Underload protection Trip time for Underload protection Type of operation for Underload protection Phase imbalance protection Trip level for phase imbalance protection Type of operation for phase imbalance protection High current protection Type of operation for high current protection Phase reversal protection Type of operation for phase reversal protection PTC protection Type of operation for PTC protection An external Bypass contactor is used High current warning Trip level for high current warning Low current warning Trip level for low current warning Overload warning Trip level for overload warning Thyristor overload warning Type of operation for phase loss fault Type of operation for by-pass doesn’t close Type of operation for by-pass doesn’t open Type of operation for fieldbus fault Type of operation for frequency fault Type of operation for heat sink over temperature fault Type of operation for thyristor short circuit fault Function of programmable input In_0 Function of programmable input In_1 Function of programmable relay output K4 Function of programmable relay output K5 Function of programmable relay output K6 Control of the softstarter with fieldbus Number of sequences for sequence start. Language to use on display Password for display Start mode Stop mode Torque limit Analog output Analog output, reference Analog output, type of value
Start Range Stop Range Overload OL Class OL Class S OL Class R OL Op Locked Rotor Lock R Lev Lock R Time Lock R Op Underload Underl Lev Underl Time Underl Op Phase Imb Ph Imb Lev Ph Imb Op High I High I Op Phase Rev Ph Rev Op PTC PTC Op Ext ByPass Warn I=High Wa I=H Lev Warn I=Low Wa I=L Lev Warn OL Wa OL Lev Warn SCR OL Ph Loss Op BP open Op BP closed Op FB Fault Op Freq F Op HS Temp Op SCR SC Op In0 In1 Relay K4 Relay K5 Relay K6 Fieldb Ctrl No of Seq Language Password Start Mode Stop Mode Torque limit Analogue Out Anl Ref Anl Type
1 ... 30 s, 1...120 s 0 ... 30 s, 0 ... 120 s No, Normal, Dual 10 A, 10, 20, 30 10A, 10, 20, 30 10A, 10, 20, 30 Stop-M, Stop-A, Ind Yes, No 0.5 ... 8.0 x Ie 0.2 ... 10 s Stop-M, Stop-A, Ind Yes, No 0.4 ... 0.8 x Ie 1 ... 30 s Stop-M, Stop-A, Ind Yes, No 10 ... 80 % Stop-M, Stop-A, Ind Yes, No Stop-M, Stop-A, Ind Yes, No Stop-M, Stop-A, Ind Yes, No Stop-M, Stop-A Yes, No Yes, No 0.5 ... 5.0 x Ie Yes, No 0.4 ...1.0 x Ie Yes, No 40 ... 99 % Yes, No Stop-M, Stop-A Stop-M, Stop-A Stop-M, Stop-A Stop-M, Stop-A Stop-M, Stop-A Stop-M, Stop-A Stop-M, Stop-A None, Reset, Enable, Jog, DOL, Start 2, FB-Dis None, Reset, Enable, Jog, DOL, Start 3, FB-Dis Run, TOR, Event Run, TOR, Event Run, TOR, Event Yes, No No, 2, 3 US/UK, FI, SE, PT, NL, IT, FR, ES, DE, CN, RU, TR, PL No, 1 ... 255 Volt, Torque Volt, Torque 20 ... 200 % Yes, No 0 ...10 V, 0 ... 20 mA, 4 ... 20 mA I Amp, U Volt, P kW, P hp, Q kVAr, S kVA, TmpMot, TmpSCR, cosPhi
1 ... 30 s 0 ... 30 s Normal 10 10 10 Stop-M No 4,0 x Ie 1.0 s Stop-M No 0.5 x Ie 10 s Stop-M No 80 % Stop-M No Stop-M No Stop-M No Stop-M No No 1.2 x Ie No 0.8 x Ie No 90 % Yes Stop-M Stop-M Stop-M Stop-M Stop-M Stop-M Stop-M Reset Reset Run TOR Event No No US/UK
36 1SXU 132 019 C0202
Volt Volt 150 % No 4 ...20 mA I Amp
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PST30 ... 300 and PSTB370 ... 1050 Technical data/Settings
ta
rte
1
rs
Tripping curves for the integrated electronic overload protection All units have an integrated electronic overload protection possible to set on four different tripping classes. Below you find a curve for each tripping class in cold state.
Time (s) 10 000
1000
100
Class 30 Class 20 Class 10 Class 10A
10
1
0
0
1
2
3
4
5
6
7
Tripping curves for electronic overload protection (Cold)
8 Current (x Ie)
ABB FieldBusPlug Controlling possibilities when using different field buses AS-Interface DeviceNet
Profibus DP V0
Profibus DP V1
Modbus-RTU
Simple control (start/stop etc) X X X X X Complete control – X X X X Simple status information X X X X X Detailed status information – X X X X Possibilities to write parameters – X X X X Possibilities to read parameters – X – X – For more detailed information, please see the Installation and Commissioning manual available at www.abb.com/lowvoltage on the Softstarter pages.
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
37 1SXU 132 019 C0202
rs
t
fts
1
So
te ar
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Technical data/Settings
Cross section of connectable cables Main circuit Available terminals: (For external by-pass):
Type of softstarter PST30 ... 72
PST85 ... 142
PST175 ... 300
PSTB370 ... 470
PSTB570 ... 1050
L1, L2, L3 T1, T2, T3
Yes Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
B1, B2, B3
Yes
Yes
Yes
No
No
Connection clamp
Solid/Stranded Solid/Stranded
1 x mm2 2 x mm2
10 ... 95 6 ... 35
See accessories See accessories
See accessories See accessories
– –
– –
Tightening torque (recommended), Nm
6.0
See accessories
See accessories
–
–
Connection bar
No 6
22.5
ø 8.5
18
ø 6.5
ø 10.2
22.5 E1861D
– –
E1860D
mm mm
E1859D
Width and thickness Hole diameter
40
6
5
E1858D
25
20
17.5 5
ø 6.5 ø 12.5
Tightening torque (recommended), Nm
–
9
ø 10.5 40
Supply and control circuit Connection clamp
49
Yes
Yes
Yes
Yes
Yes
Solid/Stranded
1 x mm2
2.5
2.5
2.5
2.5
2.5
Solid/Stranded
2 x mm2
1.5
1.5
1.5
1.5
1.5
Tightening torque (recommended), Nm
0.5
0.5
0.5
0.5
0.5
Fuse ratings and power losses
Recommended ABB Overload protection For Current softstarter range Type Type A
PST
PST30 PST37 PST44 PST50 PST60 PST72 PST85 PST105 PST142 PST175 PST210 PST250 PST300
Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
9...35 11...43 13...51 15...58 18...69 22...83 25...98 32...120 43...163 53...201 63...241 75...288 90...345
Max 2) power loss at Maximum fuse ratings - main circuit 1) Bussmann fuses Ferraz fuses rated Ie W A Type Holder A Type
Power requirements supply circuit VA/VA pull in
100 120 140 160 190 230 270 325 435 540 645 765 920
5 5 5 5 5 5 10 10 10 15 15 15 15
80 125 160 160 200 250 315 400 450 500 630 700 900
170M1366 170M1368 170M1369 170M1369 170M1370 170M1371 170M1372 170M3019 170M3020 170M3021 170M5012 170M5013 170M5015
170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H1007 170H3004 170H3004 170H3004 170H3004 170H3004 170H3004
100 160 200 200 250 315 400 400 500 550 630 630 900
6,6 URB 000 D08V 0100 6,6 URB 000 D08V 0160 6,6 URD 30 D08A 0200 6,6 URD 30 D08A 0200 6,6 URD 30 D08A 0250 6,6 URD 30 D08A 0315 6,6 URD 30 D08A 0400 6,6 URD 30 D08A 0400 6,6 URD 30 D08A 0500 6,6 URD 30 D08A 0550 6,6 URD 31 D08A 0630 6,6 URD 31 D08A 0630 6,6 URD 32 D11A 0900
PSTB 600 V
PSTB370 PSTB470 PSTB570 PSTB720 PSTB840 PSTB1050
PSTB 690 V
PSTB370 PSTB470 PSTB570 PSTB720 PSTB840 PSTB1050 1) 2)
Integrated Integrated Integrated Integrated Integrated Integrated
111...425 141...540 171...655 216...828 252...966 315...1207
90 110 105 110 170 170
700 900 900 1250 1500 1800
170M5013 170M5015 170M5015 170M5018 170M6018 170M6020
170H3004 170H3004 170H3004 170H3004 170H3004 170H3004
630 900 900 1250 1600 2000
6,6 URD 31 6,6 URD 32 6,6 URD 32 6,6 URD 33 6,6 URD 33 6,6 URD 33
D08A 0630 D11A 0900 D11A 0900 D11A 1250 D11A 1250 PLAF 2000
20/480 20/480 25/900 25/860 25/860 25/860
Integrated Integrated Integrated Integrated Integrated Integrated
111...425 141...540 171...655 216...828 252...966 315...1207
90 110 105 110 170 170
700 900 900 1250 1500 1600
170M5013 170M5015 170M5015 170M5018 170M6018 170M6019
170H3004 170H3004 170H3004 170H3004 170H3004 170H3004
630 900 900 1250 1600 1600
6,6 URD 31 6,6 URD 31 6,6 URD 31 6,6 URD 33 6,6 URD 33 6,6 URD 33
D08A 0630 D11A 0900 D11A 0900 D11A 1250 TTFA 1600 TTFA 1600
20/480 20/480 25/900 25/860 25/860 25/860
For the supply circuit 6A delayed, for MCB use C characteristics. See PSS page 20
38 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PST30...300, PSTB370...1050 UL ratings
ta
rte
1
rs
3-phase motor rating - In Line Softstarters
Motor power, P (hp), and nominal current, Ie A
Type
Ue 200V / 208V hp A
Ue 220V / 240V hp A
Ue 440V / 480V hp A
Ue 550V / 600V hp A
PST30 PST37 PST44 PST50 PST60 PST72 PST85 PST105 PST142 PST175 PST210 PST250 PST300 PSTB370 PSTB470 PSTB570 PSTB720 PSTB840 PSTB1050
7.5 10 10 15 20 20 25 30 40 50 60 75 100 125 150 200 250 300 400
10 10 15 20 20 25 30 40 50 60 75 100 100 150 200 250 300 350 450
20 25 30 40 40 50 60 75 100 125 150 200 250 300 400 500 600 700 900
25 30 40 50 50 60 75 100 125 150 200 250 300 350 500 600 700 800 1000
28 34 42 54 60 68 80 104 130 156 192 248 302 361 480 590 720 840 1062
28 34 42 54 60 68 80 104 130 156 192 248 302 361 480 590 720 840 1062
28 34 42 54 60 68 80 104 130 156 192 248 302 361 480 590 720 840 1062
28 34 42 54 60 68 80 104 130 156 192 248 302 361 480 590 720 840 1062
3-phase motor rating - Inside Delta Softstarters
Motor power, P (hp), and nominal current, Ie A
Type
Ue 200V / 208V hp A
Ue 220V / 240V hp A
Ue 440V / 480V hp A
Ue 550V / 600V hp A
PST30 PST37 PST44 PST50 PST60 PST72 PST85 PST105 PST142 PST175 PST210 PST250 PST300 PSTB370 PSTB470 PSTB570 PSTB720 PSTB840 PSTB1050
10 15 20 25 30 30 40 50 60 75 100 125 150 200 250 300 400 500 600
15 20 25 30 40 40 50 60 75 100 100 150 200 250 300 350 500 600 700
30 40 50 60 75 75 100 125 150 200 250 300 400 500 600 700 1000 1200 1500
40 50 60 75 100 100 125 150 200 250 300 350 500 600 700 800 1200 1500 1800
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
42 54 72 80 104 104 130 156 192 248 302 361 480 590 720 840 1247 1454 1839
42 54 72 80 104 104 130 156 192 248 302 361 480 590 720 840 1247 1454 1839
42 54 72 80 104 104 130 156 192 248 302 361 480 590 720 840 1247 1454 1839
42 54 72 80 104 104 130 156 192 248 302 361 480 590 720 840 1247 1454 1839
39 1SXU 132 019 C0202
rs
t
ts of
Type PSR, PSS, PST and PSTB Wall mounting instruction, dimensions
S
Minimum distance to wall/front
Dimensions
Softstarter, type
A
B
C
E
F
H
25 25 25
0 0 0
0 0 0
45 45 54
140 160 187
114 128 153
PSS18/30 ... 44/76 PSS50/85 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515
20 20 20 20
10 10 10 10
100 100 100 100
120 140 181 356
200 250 340 340
163 163 265 265
PSS ... -690 for 690 V PSS18/30 ... 72/124 PSS85/147 ... 142/245 PSS175/300 ... 300/515
20 20 20
10 10 10
100 100 100
140 181 356
250 340 340
163 265 265
PST - all PST30 ... 72 PST85 ... 142 PST175 ... 300
20 20 20
10 10 10
100 100 100
160 186 360
260 390 420
196 270 270
PSTB - all PSTB370 ... 470 PSTB570 ... 1050
20 20
15 15
150 150
365 435
460 515
361 381
PSR3 ... PSR45 PSR3 ... 16 PSR25 ... 30 PSR37 ... 45 PSS ... -500 for 500 V
Dimensions PSTEK
138
3
1SFC132117F0201
23
135
135 107 53.5
53.5
4.8
22.5
9.5
1SFC132118F0201
118 138
14
28
1
Softstarters
te ar
Dotted line denotes area covered by external keypad
Dimensions in mm 40 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PSR3 ... PSR45 Dimensions
ABB Inc. • 888-385-1221 • www.abb-control.com
1
rs
54 mm (2.13’’)
187 mm (7.36’’)
5 mm (0.20’’)
179 mm (7.05’’)
44 mm (1.73’’)
172 mm (6.77’’)
Low Voltage Products & Systems
rte
PSR37 … 45
4 mm (0.16’’)
PSR25 … 30
3.5 mm (0.14’’)
PSR3 … 16
ta
41 1SXU 132 019 C0202
rs
t
So
Type PSS18/30 ... PSS300/515 Dimensions PSS50/85-500 … 72/124-500 PSS18/30-690 … 72/124-690
10
162
1SFC132122F0201
PSS18/30-500 … 44/76-500
10
120 105
1SFC132124F0201
fts
162
1
Softstarters
te ar
7,5
140
)
264,5 132,5
17,5 20
1SFC132128F0201
5
PSS 175/300-500 … 300/515-500 PSS 175/300-690 … 300/515-690
1SFC132126F0201
265
132,5
5
PSS85/147-500 … 142/245-500 PSS85/147-690 … 142/245-690
(4x
9
,5 ø6
1SFC132125F0201
2
9
(4x
234
1SFC132123F0201
200
184 2
)
,5
ø6
250
7,5
125
35 35 43,75
43,75
181
42 1SXU 132 019 C0202
1SFC132129F0201
340
320
ø7 (4x) 10
Dimensions in mm
11,5
340 1SFC132127F0201
(4x
10
)
ø7
356 333
11,5
320
158
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PST30 ... 300 and PSTB370 ... 1050 Dimensions PST85 ...142
rte
1
rs
1SFC132130F0201
PST85 ...142 with marine kit
155
46,5
262
PSTB370 ... 470
PSTB570 ... 1050
460
PST175 ... 300
1SFC132131F0201
46,5
52,5
7
390
251
64,5
12
270
PST30 ... 72
ta
Dimensions in mm Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
43 1SXU 132 019 C0202
rs
1
te ar
t
ts of
S
Softstarters
Type PSR3 ... PSR45 Diagrams
PSR3 ...16 A) With MMS
B) With MMS and auxiliary contact
C) With fuses, contactor and O.L.
E) With MMS and auxiliary contact
F) With fuses, contactor and O.L.
PSR25 ... 45 D) With MMS
44 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Softstarters
Type PSS18/30 ... PSS300/515 Diagrams
So
fts
ta
rte
1
rs
PSS18/30…300/515
F6
Temperature monitor
K5
Relay, actuated at full voltage (Ue = 100%)
K6
Relay, fault signal
T1
Control transformer
T2
Current transformer
V1-V6 Thyristor
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
45 1SXU 132 019 C0202
rs
1
t
fts
So
te ar
Softstarters
Type PST30 ... 300 and PSTB370 ... 1050 Diagrams
PST30...300
PSTB370...1050
46 1SXU 132 019 C0202
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
So
Softstarters
fts
Type PSR, PSS, PST and PSTB Certifications and Approvals
ta
rte
1
rs
The table below shows the approvals and certifications for different softstarters. For approvals and/or certificates not listed below, please contact your local ABB sales office. Certifications and approvals Certifications
Abbreviation Approved in
Approvals: ship classification societies
CE EU
UL USA
cULus USA
CSA Canada
CCC China
GOST Russia
ANCE C-tick Mexico Australia
LRS Gr.Britain
Germany
GL
PSR3 ... PSR45 PSR3
•
•
•
–
•
–
–
•
–
–
PSR6
•
•
•
–
•
–
–
•
–
–
PSR9
•
•
•
–
•
–
–
•
–
–
PSR12
•
•
•
–
•
–
–
•
–
–
PSR16
•
•
•
–
•
–
–
•
–
–
PSR25
•
•
•
–
•
–
–
•
–
–
PSR30
•
•
•
–
•
–
–
•
–
–
PSR37
•
•
•
–
•
–
–
•
–
–
PSR45
•
•
•
–
•
–
–
•
–
–
PSS18/30...300/215
PSS18/30
•
•
–
•
•
•
•
•
•
–
PSS30/52
•
•
–
•
•
•
•
•
•
–
PSS37/64
•
•
–
•
•
•
•
•
•
–
PSS44/76
•
•
–
•
•
•
•
•
•
–
PSS50/85
•
•
–
•
•
•
•
•
•
–
PSS60/105
•
•
–
•
•
•
•
•
•
–
PSS72/124
•
•
–
•
•
•
•
•
•
–
PSS85/147
•
•
–
•
•
•
•
•
–
–
PSS105/181
•
•
–
•
•
•
•
•
–
–
PSS142/245
•
•
–
•
•
•
•
•
–
–
PSS175/300
•
•
–
•
•
•
•
•
–
–
PSS250/420
•
•
–
•
•
•
•
•
–
–
PSS300/515
•
•
–
•
•
•
•
•
–
–
PST30
•
•
–
•
•
•
•
•
–
•
PST37
•
•
–
•
•
•
•
•
–
•
PST44
•
•
–
•
•
•
•
•
–
•
PST50
•
•
–
•
•
•
•
•
–
•
PST60
•
•
–
•
•
•
•
•
–
•
PST72
•
•
–
•
•
•
•
•
–
•
PST85
•
•
–
•
•
•
•
•
–
•
PST105
•
•
–
•
•
•
•
•
–
•
PST142
•
•
–
•
•
•
•
•
–
•
PST175
•
•
–
•
•
•
•
•
–
•
PST210
•
•
–
•
•
•
•
•
–
•
PST250
•
•
–
•
•
•
•
•
–
•
PST300
•
•
–
•
•
•
•
•
–
•
PSTB370
•
•
–
•
•
•
•
•
–
•
PSTB470
•
•
–
•
•
•
•
•
–
•
PSTB570
•
•
–
•
•
•
•
•
–
•
PSTB720
•
•
–
•
•
•
•
•
–
•
PSTB840 PSTB1050
• •
• •
– –
• •
• •
• •
• •
• •
– –
• •
PST30...PSTB1050
• Standard design approved, the company labels bear the certification mark when this is required. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
47 1SXU 132 019 C0202
Leader in power and automation technologies ABB (www.abb.com) is a leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. The ABB Group of companies operates in around 100 countries and employs about 107 000 people.
Division Automation Products
The division Automation Products serves customers in the automotive, chemicals, consumer, electronics, life sciences, manufacturing, marine, metals, minerals, paper, petroleum, turbochargers and utility industries. Besides strong domain knowledge of the industries we serve, our offer includes measurement, control, communication, instrumentation, drives, motors, power electronics, software and a broad range of low-voltage products. Much of this is sold through external channel partners such as distributors, system integrators, contractors and original equipment manufacturers.
Low voltage products
Due to ABB’s broad program of product standardization, components of today are the ‘building blocks’ of system solutions, incorporating functionalities that will allow seamless integration in real-time automation and information systems. At the product level, all the low voltage products can operate together perfectly. To create a system solution every product included has to be equipped with the tools necessary to install, operate and maintain it efficiently throughout the product life cycle. The range of low voltage product is supported by technical documentation. This together with design and compact unit makes it easier than ever to incorporate our products in your system. Our customers can find all product related documentation such as brochures, catalogues, selection program, certificates, drawings and other information directly at: www.abb.com/lowvoltage.