Amacan K

Baureihenheft 1579.5/3--10

Applications

Sewage pumps, mixed water pumps and activated sludge pumps in sewage treatment plants, irrigation and drainage pumping stations. Storm water pumps for flood protection, water pollution control and industrial refuse tip effluents, for pumping all pre--screened or pre--settled media not liable to twist.

Submersible motor pump with channel-type impeller for installation in discharge pipes

Operating data Heads Capacity -- standard programme : -- custom--made programme : Motor power Product temperature: max. submersion level:

H up to

30 m

Q up to 1000 l/s Q up to 2000 l/s P2 up to 320 kW up to 40 °C 20 m

Design Wet installed, close--coupled pump with channel--type impeller, single--stage, single--entry, for installation in discharge pipes.

Drive Three-phase asynchronous motor, winding acc. to IEC 38 for 400/690V supply voltage (also suitable for 380 V and 415 V mains), enclosure type 58 to IEC 34-5/IP 68 to DIN 40050, motor design to VDE 0530 part 1/IEC 34--1, insulation class F, for flameproof units also VDE 0171/5.78 parts 1 and 5/ EN 50014/EN 50018, protection type EEx d IIB T3.

Bearings -- up to motor sizes 646, 548 : grease lubricated, maintenance--free anti--friction bearings -- up to motor sizes 806, 678, 4310 : grease lubricated anti--friction bearings, re--lubrication without dismantling the pumpset.

Shaft sealing

OW 380 092-00

Shaft sealing is effected by means of two elastomer bellows mechanical seals in tandem arrangement, independent of the direction of rotation. A liquid chamber filled with environment--friendly non--toxic paraffin oil between the seals ensures cooling and lubrication.

Automation products available: · PumpExpert · Hyamaster · hyatronic

Designation Amacan

K 800-380 / 64 6 U X

Pump type Channel type impeller DN of discharge pipe [mm] Impeller diameter [mm] Motor power P2 in kW

(only correct for U motor designs)

Number of poles in the motor Motor design Material code

U/U1/U2 = product temperature 30 °C X/X1/X2 = flameproof, product temperature 40°C G = grey cast iron G1= grey cast iron with variants G3= sea water design

G

Materials

Pump casing GG-25 Motor housing GG-25 Pump shaft C 45 N Shaft prot. sleeve 1.4021.05 Impeller GG-25/Noridur â Nuts and bolts A 4/1.4462 Casing wear ring GG-25/VG 434 Cathodic corrosion protection available

Amacan K Selection chart 50 Hz

H [m]

Q [l/s] Q [m3/h]

Standard programme Custom--made programme

2

Amacan K Range chart 60 Hz

H [m]

Q [l/s] Q [m3/h]

3

Amacan K Product advantages to the benefit of our customers

Cable mounted with strain relief.

Especially designed lug for receiving crane hook allows installation and removal even when inlet chamber is flooded. (No need to enter the pit!)

The cable entry is completely watertight with insulation at several points: 1. Long rubber gland 2. Cable embedded in cast resin 3. Conductors embedded in cast resin 4. Soldered strands Even in the event of damage to the cable and core insulation there is no possibility of moisture entering the motor chamber along the strands due to capillary action.

Increased efficiency thanks to motor shaft made of ferromagnetic steel Operationally safe, dry, three-phase asynchronous motor, surface cooled, in acc. with VDE regulations (from the KSB submersible pump range) Thermal protection prevents motor from overheating Early fault detection by means of bearing temperature monitoring (from motor /286 and /258 onwards) Inspection ports for separate functional test of mechanical seals

Patented, standard moisture sensor as additional safety device. Motor housing with stator removable after loosening the flange connections (simple visual inspection of the motor)

Mechanical seals in tandem arrangement, trouble-free operation guaranteed for many years due to a common liquid feed with large air cushion for expansion and high quality, wear-resistant sealing materials. Shaft sleeve protects the pump shaft against corrosion

Mechanical seal monitored by means of float switch in the leakage chamber

Two- or three-channel impeller with large free passage

High operational safety due to protected sealing chamber. Renewable casing wear ring protects casing against wear OW 380 109-00

Self-centering positioning of the pump in the discharge column by its own weight. Sealing ensured by an O-ring. No additional anchoring or rotational protection required. Fast installation and removal of pump as disconnection of pipes and cables is not necessary.

The illustration shown corresponds to Amacan K 1000--420

4

Amacan K Table of Contents

Programme and scope of supply, order data, general comments

Page 6

Table of pumped media, impeller types

Page 7

Modes of installation

Page 8

Technical data, warranty, testing and quality assurance, operation with frequency converter, materials, coating

Pages 9 -- 12

Connection of monitoring equipment

Pages 13

General drawings

Pages 14 -- 17

Mechanical seal -- detail

Pages 18 -- 19

Dimension tables -- pump/discharge pipe

Pages 20 -- 23

Installation plans

Pages 24 -- 29

Pump with suspension wire and turnbuckle in discharge pipe, discharge pipe cover with cable entry

Pages 30 -- 32

Selection table -- example

Page 33

Characteristic curves

Pages 34 -- 55

For further motor data refer to motor documentation: Amarex KRT Reference-No. 2553.53/...-90

5

Amacan K Programme Standard pump programme : pumpsets up to sizes 1200-540, n = 980 1/min as described in this brochure Custom-made programme : pumpsets from size 1200-540 on, n = 980 1/min, motor power P2 > 200 kW with various drives. Hydraulic data on request.

Scope of supply Basic version :

pump unit complete and ready for installation, 400 V / 50 Hz, supplied with10 m power cable, without performance test (deviations from the basic version will result in extra charges and longer delivery period).

Accessories available / required: -- steel discharge pipes in various designs -- lifting rope complete with cable protection (obligatory from 3.5 m of free cable length in the discharge pipe onwards) -- monitoring unit

General comments Our pump units comply with enclosure type IP 68 in accordance with DIN 40050 and therefore include the lesser requirements of IP 58 of IEC 34--5 valid since April 1, 1988. During production the pumps and motors are subjected to functional tests both independently and as a unit. Head and power rating apply only to pumped liquids with a density of ρ = 1 kg/dm3 and kinematic viscosity ν up to 20 mm2/s. Motor ratings P2 should have a safety factor which is adequate for a particular pumping application (see selection example on page 33). To facilitate transportation the electrical cabling will be supplied separately from cross--sectional area 4x50 mm2 upwards. Applicable drawing numbers are indicated below the drawings.

Order data --------

6

Designation of pump unit according to ”Designation” / ”Selection of pump” Capacity Q Total head H (Hgeo and plant losses) Liquid handled and liquid temperature Voltage, frequency, starting method, length of cable Accessories required -- (for discharge pipes, please indicate installation mode and relevant levels) Quantity and language of operating instructions

Amacan K List of liquids handled The application of submersible pumps is versatile and subject to local conditions which are distinct from case to case. The following list serves as recommendation only! For profound counselling in all questions of planning, consult your nearest KSB sales agency or our technical divisions. Liquid handled 1)

The end user should decide whether flameproof motors are necessary

Dirty water River water Rain water Sewage Activated sludge

Indication, recommendation

free impeller passage, larger than solids occuring prescreened p esc ee ed or o pre--settled p e se ed if necessary ecessa y max. 3% dry substance content material combination G3, tmax = 30 °C, anode check every 6 months

Sea water Industrial effluent, contaminated with ... -- paint suspension -- varnish suspension -- fibrous material -- abrasive material Industrial effluent, slightly acid

free of solvents, refer to operator’s instructions! free of solvents, for silicon--free version consult KSB short fibres, not liable to twist variant ”G1” 3) - 0.5 g/l max. solids content ph-Wert ³ 6 variant ”G1” 3) plus INERTOL POXITAR coating

Chemically neutral waste water -- ammonia water -- ammonia hydroxide 5% NH4OH -- urea 25% (NH2)2-CO -- potassium hydroxide 10% KOH -- calcium hydroxide 5% Ca(OH)2 -- sodium hydroxide 5% NaOH -- sodium carbonate 30% Na2CO3 Chemically neutral waste water contaminated with ... -- aliphatic hydrocarbons e.g. oils, petrol, butane, methane

with polyamide cable sheath or Tefzel cable 2)

-- aromatic hydrocarbons e.g. benzene, styrene

FPM (VITON) O-rings and TEFZEL cable 2)

-- chlorinated hydrocarbons e.g. trichlorethylene, ethylene chloride, chloroform, methylene chloride

FPM (VITON) O-rings and TEFZEL cable 2)

1) Liquids not mentioned here require in most of the cases upgraded materials. Please consult KSB. 2) Modified fluoropolymer ETFE, standard variant (page 10 und 11) to be ordered separately 3) Standard variant (page 12) to be ordered separately

Impeller type Closed channel--type impeller (K impeller) for contaminated non--gaseous liquids containing solids, not liable to twist

Note:

K-impellers are trimmed to meet the exact duty point.

7

Amacan K Types of installation

OW 380 086--00

BU

Steel discharge pipe overflow design

OW 380 088--00

CU

OW 380 089--00

DU

Steel discharge pipe with floor-mounted discharge nozzle

Inclined installation on request.

8

Steel discharge pipe with underfloor discharge

OW 380 087--00

CS

Design variant of installation mode CU, under installation cover in floor, foot--mounted (on request)

Amacan K Technical data Size

Pipe dia. req. [mm]

n [1/min]

Impeller no. of blades

Free passage [mm] 70x92

Standard programme 700-330

700

735

3

700-330

700

980

3

70x92

700-321

700

735

2

105x115

700-321

700

980

2

105x115

700-324

700

735

3

70

700-324

700

980

3

70

800-370

800

980

3

75

800-380

800

735

3

115x95

800-381

800

735

2

145x135

800-380

800

980

3

115x95

800-381

800

980

2

145x135

1000-420

1000

735

3

126x100

1000-421

1000

735

2

140x150

1000-420

1000

980

3

126x100

1000-421

1000

980

2

140x150

1000-500

1000/1300 *

980

3

145x110

1200-540

1200

590

3

133x150

1200-540

1200/1300 *

735

3

133x150

1200-540

1300

980

3

133x150

Custom--made programme 1200-540

1400

980

3

133x150

1300-520

1300

590

3

145

1300-520

1300/1400 *

735

3

145

1300-750

1400

490

3

180

1300-750

1300/1400

590

3

180

*) depending on the motor size (see page 21)

9

Amacan K Technical data -- Pumpset K 700-330 K 700-324/321 K 800-370 K 800-380/381

Pump sizes

K 1000-420/421 K 1000-500 K 1200-540 K 1300-520 K 1300-750

Characteristics Motor versions :

6 - pole

20 6

26 6

28 6 ... 64 6

80 6 ... 120 6

138 6 ... 200 6

260 6 ... 320 6

U = non-flameproof

8 - pole

10 8; 17 8

21 8

25 8 ... 54 8

67 8 ... 107 8

126 8 ... 180 8

225 8 ... 280 8

43 10 ... 84 10

107 10 ... 170 10

215 10 ... 270 10

X = flameproof

10 - pole

mechanical

12 - pole

132 12 ... 200 12

Typical sectional drawing / motor size DKN

p.14 161; 181

Shaft sealing pump -- motor

2 bellows mech. seals, independent of direction of rotation, in tandem arrangement

Anti-friction bearing with re-lubrication facility Typical mech. seal detail p. .18/19

p.15 225

p.16 280

-

ill. 1 OW 309 124-00

ill. 2 OW 309 110-00

1

Enclosure

Pressure-tight enclosure IP 58 to IEC 34-5/IP 68 to DIN 40050 VDE 0171/1.69 0171/5.78 EN50014/50018

----

(Ex) dll G3 VDE 0171/1.69

-

-

-

Windings for 400V/50 Hz mains (suitable for 380 ... 415 V)

elektrical

230 V

400 V delta ; 690 V star

----

1 with special winding

500 V

1

690 V

1

with special winding

`

Starting mode

d.o.l. or star--delta

Motor cooling

by surrounding pumped liquid, S 1 operation

-

Cable length > 10 m Cable entry

1 (> 50m `)

U;X

resin filled cable gland (for cross sectional area 4 x 35 mm2)

Polyamide cable sheath TEFZEL 1) cable (waterproof over full length) Operated with frequency inverter 2) modified fluoropolymer ETFE see page 11

10

star connected

with standard winding star connected

other voltages

Cable length 10 m

1) 2)

`

----

Insulation class F

Windings for mains voltage

---355

----

Elastomers in Viton (for O-Rings and mech. seal)

Explosion protection

p.17 315

----

1 `

1 - = standard 1 = standard design variant

(flameproof version `) ` = special version ---- = not available

Amacan K Technical data -- Pumpset K 700-330 K 700-324/321 K 800-370 K 800-380/381

Pump sizes

K 1000-420/421 K 1000-500 K 1200-540 K 1300-520 K 1300-750

Characteristics Motor versions :

6 - pole

20 6

26 6

28 6 ... 64 6

80 6 ... 120 6

138 6 ... 200 6

260 6 ... 320 6

U = non-flameproof

8 - pole

10 8; 17 8

21 8

25 8 ... 54 8

67 8 ... 107 8

126 8 ... 180 8

225 8 ... 280 8

43 10 ... 84 10

107 10 ... 170 10

215 10 ... 270 10

X = flameproof

10 - pole

Monitoring page 13

Operating limits

12 - pole

132 12 ... 200 12

max. permissible submersion level

U

25 m

X

20 m

Pumped liquid temperature

U

30 °C

X

40 °C

U

automatic on/off when permissible winding temp. has been reached (control circuit)

temperature control of the winding

X

2 separate control circuits

---

automatic on/off control when permissible winding temp. has been reached (control circuit) trip control when the flameproof temperature limit has been reached (limitation circuit)

Temp. control of pump-side anti--friction bearings (PT 100)

----

Moisture electrode in the motor housing

`

-

----

-

Float switch in the leakage chamber to monitor mech. seal

- = standard 1 = standard design variant

-

`

` = special version ---- = not available

Warranty, tests and quality assurance Every pump is subjected to a functional test. We grant a warranty for pump performance(non--witnessed) in line with ISO 9906/A or similar/equivalent international standards. Witnessed performance test in acc. with ISO or equivalent standards possible. The high quality of our pumps is ensured by constant quality checks.

Frequency inverter operation Only 95 % of the motor power P2 must be utilized. For flameproof units, only thermistor tripping devices with PTB approval must be used. Observe the exception on page 13 (ill. 1).

11

Amacan K Materials Material combinations

G

G3 1) (Sea water version)

G1

Part No.

Designation

101

Pump casing

GG-25

113

Intermediate casing

GG-25

138

Inlet nozzle 2)

GG-25

163

Discharge cover

230

Impeller

350

Bearing housing

360

Bearing cover

Materials

3)

GG-25 9.4460 4)

GG-25

GG-25 GG-25 NBR

5)

Viton 6)

412

O--ring NBR

421

Shaft seal ring NBR

433.01

Mechanical seal

Carbon / cast chrome

433.02

Mechanical seal

Silicon carbide / silicon carbide

502

Casing wear ring

524

Shaft protecting sleeve

571

Lifting lug

811

Motor housing

GG-25

812

Motor housing cover

GG-25

818

Shaft (rotor): up to motor DKN 161/181

Cable entry

div.

Bolts

99-16

Anode

818

Shaft (rotor)

1) 2) 3) 4) 5) 6) 7) 8)

GG-25

VG 434 ST 37 7)

1.4021.05

1.4057 C 45 N

8)

GG 1.4462 / 1.4571 ----

Zn C 45 N

Standard surface coating Primer and final coat Surface treatment: SA 2 1/2 (SIS 055900) AN 1865 Corrosion prevention to AA 0080-06-01 Primer: iron oxide (dipped) 0.035 mm to 0.040 0.0m Top coat: KSB standard coating, approx.0.070 mm (RAL 5002)

Standard design variant: -- sea water version: Primer and INERTOL POXITAR Surface treatment see standard Primer: see standard + wash primer INERTOL POXITAR, approx. 0.250 mm (2-component epoxy-tar coating) Top coat:

Special surface treatment Available at extra charge and longer delivery periods 12

VG 434

1.4021.05

Pump units with cathodic protection: check anode every 6 months for pump sizes 1300--520 and 1300--750 for pump size 700--330 Noridur Nitrile (Perbunan) Fluororubber FPM Lifting lug in 1.4462 dry shaft in the pump area (shaft-protecting sleeve in chromium steel)

Standard:

Viton 6)

NBR 5)

Shaft (rotor): from motor DKN 225 on 834.1/.2

9.4460 4)

Amacan K Connection of monitoring equipment Thermal motor monitoring for range of capacity > 4 kW to 30 kW 21

22

10

bimetal

11

Motor version ”U” and ”W” (non-flameproof)

Motor version ”X” and ”Y” (flameproof)

21

22

Connected directly into the control circuit of motor contactor

21

22

Connected directly into the control circuit of motor contactor

10

11

Not required, if supplied connect to dummy terminal

10

11

Connected via thermistor tripping with manual reset

PTC

Ill 1

Thermal motor monitoring for all other Amacan K sizes

20

21

10

bimetal

11

Non-flameproof ”U”

Flameproof ”X”

20

21

Not required, if supplied connect to blank terminal

20

21

Connected directly into the control circuit of the motor contactor 2)

10

11

Connected via thermistor tripping device with automatic reset

10

11

Connected via thermistor tripping device with manual reset 1)

PTC

Ill 2

Thermal monitoring of pump-side ball bearing 15

Moisture detection probe in motor housing

16

Connected via PT100 tripping relay e.g. make Kriwan type PT100--2AV Ill 3

3

9

16

9

Connected to earth leakage circuit breaker, nominal current leakage 30--50 mA

4

float switch

moisture sensor

PT100

15

Mechanical seal monitoring via float switch

3

4

Connected for alarm, i.e. switch off

Ill 4

Ill 5

1)

For inverter operation with flameproof requirements, PTB--approved tripping devices are required, e.g. make Siemens type 3UN6 with manual reset. 2) KSB tripping device available with both functions 20

21

= identity of conductor

Bi-Metall / PTC = temperature sensor in the winding

13

Amacan K Sectional drawing typical for sizes < 4 kW to 30 kW 571 914.26 920.26 550.26 529 322 932.01 421.01 811/81-59

932.03

818

321.02 914.02 412.02 441

834 914.04

412.03

412.07

330 932.02

81-17

903

900.28

411.03 81-56

903.15

81-44.28 81-18 99-17 902.01 920.01 412.04 113 433.01 433.02 412.20

260

0W 383650-00

914.10

940.03

101

502

230

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

101

Pump casing

421

Lip seal

818

Rotor

113

Intermediate casing

433

Mechanical seal

834

Cable duct

230

Impeller

502

Casing wear ring

900

Bolt

260

Impeller hub cap

529

Bearing sleeve

902

Stud

321

Radial ball bearing

550

Disc

903

Screw plug

322

Radial roller bearing

571

Lug

914

Socket head cap screw

330

Bearing bracket

81-17

Cable crimp

920

Nut

411

Joint ring

81-18

Cable socket

932

Circlip

412

O-ring

81-56

Moisture protection of motor

99-17

Desiccant

14

Amacan K General arrangement drawing Amacan K 800-370 to 1000-420/421 , motors 28 6 to 54 8 550.25

901.25 550.25

920.25

81-97.2 59-71

68-3.2

571

901.26

914.01 500.04 412.01

322 932.01

812 421.01 500.01 80-1

81-22 81-56

818 360

81-45 411.26

321 901.01 550.02 550.01 932.02 412.02

99-17 914.02 412.09 914.06

433.01 903.03 433.02 411.03 412.05

421.02 500.02 350

903.04 411.04

903.5 411.05 412.04 902.01 920.01 113 411.06

OW 380 103-00

550.23 412.06

931.01

901.21

940.03

260

502

230

101

412.20

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

101

Pump casing

421

Lip seal

81-56

Moisture protection of motor

931

Lock washer

113

Intermediate casing

433

Mechanical seal

81-97

Cable protector

932

Circlip

230

Impeller

500

Ring

812

Motor casing cover

940

Key

260

Impeller hub cap

502

Casing wear ring

818

Rotor

99-17

Desiccant

321

Radial ball bearing

550

Disc

834

Cable duct

322

Radial roller bearing

571

Lug

901

Hexagon bolt

350

Bearing housing

68-3

Cover plate

902

Stud

360

Bearing cover

80-1

Semi-finished motor

903

Screw plug

411

Joint ring

81-22

Terminal box cover

914

Socket head cap screw

412

O-ring

81-45

Float switch

920

Nut

15

Amacan K General arrangement drawing Amacan K 1000-420/421 to 1300-520 , motors 80 6 to 84 10 Amacan K 1300-520 with inlet nozzle (Part No. 138)

550.25

A -- A

901.25 550.25

920.25

81-97.2

68-32

59-71

571 901.26

812 914.01

903.01 411.01 636.01

412.01 500.04 322

500.01 520.01 80-1

932.01 421.01

818 360 500.03

412.09

647

81-22

320 901.01 550.02 932.02

421.03

550.01

500.05

500.02

81-56

350

914.06

903.03 411.03 636.02 903.02 411.02 903.04 411.04

412.02 914.02 99-17 412.03 81-45 421.02 411.26 903.05 411.05 902.01 920.01 412.04 412.05 113 411.06 433.01 433.02

OW 380 104-00 230 412.20

940.03 931.01 412.06 502 101

550.23 901.21

260

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

101 113 230 260 320 322 350 360 411 412

Pump casing Intermediate casing Impeller Impeller hub cap Anti--friction bearing Radial roller bearing Bearing housing Bearing cover Joint ring O-ring

421 433 500 502 520 550 571 636 647 68-3

Lip seal Mechanical seal Ring Casing wear ring Sleeve Disc Lug Grease nipple Grease regulator Cover plate

80-1 81-22 81-45 81-56 81-97 812 818 901 902 903

Semi-finished motor Terminal box cover Float switch Moisture protection of motor Cable protector Motor casing cover Rotor Hexagon bolt Stud Screw plug

914 9

S Socket head cap p screw

920 931 932 940 99-17

Nut Lock washer Circlip Key Desiccant

16

Amacan K General arrangement drawing Amacan K 1000-500 to 1300-520 , motors 138 6 to 170 10 (Standard programme) Amacan K 1300-520 with inlet nozzle (Part No. 138) 571 901.26 500.04 322

901.04

932.01 903.01 411.01 636.01 500.01 421.01 520.01 360 500.03

914.01 412.01 812 80-1

421.03 647

818

320 834.01 834.03

500.05 550.01 932.02 901.01 550.02 500.02

412.12 69-6 81-56

421.02

411.26

412.03 350

902.03 920.03 412.02

903.03 411.03 903.02 411.02 636.02

99-17 914.02 903.05 411.05 902.01 920.01

903.04 411.04 916.02 914.03 411.06

81-45 412.04

916.03

412.05 113 433.01 433.02

OW 380 105-00

940.03

550.23

260

931.01 230 901.21 412.06 502

101

412.20

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

Part No.

Part Designation

101 113 230 260 320 322 350 360 411 412

Pump casing Intermediate casing Impeller Impeller hub cap Anti--friction bearing Radial roller bearing Bearing housing Bearing cover Joint ring O-ring

421 433 500 502 520 550 571 636 647 69-6

Lip seal Mechanical seal Ring Casing wear ring Sleeve Disc Lug Grease nipple Grease regulator Temperature sensor

80-1 81-45 81-56 812 818 834 901 902 903 914

Semi-finished motor Float switch Moisture protection of motor Motor casing cover Rotor Cable duct Hexagon bolt Stud Screw plug Socket head cap screw

916 920 931 932 940 99-17

Plug Nut Lock washer Circlip Key Desiccant

17

Amacan K Mechanical seal detail

433.01

551.01

932.03 433.02

524 562.13 412.17

OW 309 124-00

figure 1 Seal variants for different pump types see table on p.10

Part No.

Part designation

Part No.

Part designation

433.01

Mechanical seal

551.01

Spacer sleeve

433.02

Mechanical seal

562.13

Parallel pin

412.17 524

O-ring Shaft protection sleeve

932.03

Circlip

18

Amacan K Mechanical seal detail

433.01 550.03 932.03 500.06 914.07 433.02 524 412.17 940.13 OW 309 110-00

figure 2

Seal variants for different pump types see table on p.10

Part No.

Part designation

Part No.

Part designation

433.01

Mechanical seal

433.02

Mechanical seal

550.03 914.07

Disc Socket head cap screw

412.17

O-ring

932.03

Circlip

500.06 524

Ring Shaft protection sleeve

940.13

Key

19

Amacan K Dimension tables for pump and support ring

OW 380 111-00

OW 380 085-00

d7 b20

20

Amacan K Pump and support ring all dim. in mm, standard programme up to 1200-540/10710 2, custom--made progr. from 1200-540/2606 upwards h1

h2

d1

d2

b

c

D

d7

b20

h20

f20

/ / / /

206 266 108 178

1195 1170 1195 1195

1000 975 1000 1000

670

556

250

130

711

570

691

60

5

/ / / /

206 266 108 178

1195 1170 1195 1195

1000 975 1000 1000

670

556

250

130

711

570

691

60

5

/ / / / /

206 266 286 376 456

1155 1130 1400 1400 1400

960 935 1080 1080 1080

640

250 250 369 369 369

130 130 232 232 232

813

656

793

60

2

/ / / / / / / / /

266 286 2 376 456 646 178 218 258 1 338 1

1225 1495 1495 1495 1600 1250 1225 1495 1495

930 1175 1175 1175 1280 1055 930 1175 1175

640

250 369 369 369 369 250 250 369 369

130 232 232 232 232 130 130 232 232

813

656

793

60

2

1575 1575 1680 1695 1695 1695 1575 1575 1680 1680

1255 1255 1360 1345 1345 1345 1255 1255 1360 1360

369 369 369 449 469 469 369 369 369 369

232 232 232 232 232 232 232 232 232 232

1016

856

992

70

8

1700 1900 1900 2150 2150 2150

1350 1550 1550 1770 1770 1770

449 469 469 577 577 577

232 232 232 382 382 382

70

8

2205 2205 1955 1955 2205 2205 2205 1765 1955 1955 1955 2205

1825 1825 1605 1605 1825 1825 1825 1415 1605 1605 1605 1825

577 577 469 469 577 577 577 449 469 469 469 577

382 382 232 232 382 382 382 232 232 232 232 382

70

2

2700

1935

--

--

1420

70

2

577

382

1320

622

494

1420

60

5

60

5

Amacan K . . . - . . . / . . .U/X . 700-330

700-324/321

800-370

800-380/381

1000-420/421

1000-500

(1300-500)

/ 376 / 456 / 646 / 806 / 1026 / 1206 / 258 / 338 / 438 / 548 / / / / / /

1 1 1 1

2 2 2

806 1 1026 1206 1386 1656 2006

(1300-540) (1300-540) 1200-540 1200-540 (1300-540) (1300-540) (1300-540) 1200-540 1200-540 1200-540 1200-540 (1300-540)

/ 1656 / 2006 / 848 / 1078 / 1268 / 1508 / 1808 / 4310 / 5410 / 6710 / 8410 /10710

(1400-540) (1400-540) 1300-520 1300-520 1300-520 (1400-520) 1300-520 1300-520 1300-520 1300-520

/ / / / / / / / / /

2606 3206 1268 1 1508 1 1808 1 2258 1 6710 1 8410 1 10710 1 12610 1

1300-750 (1400-750) (1400-750) (1400-750) (1400-750) (1400-750) (1400-750) (1400-750)

/ / / / / / / /

17010 2 21510 2 23510 2 27010 2 11012 13012 15512 18012

2 2 2 2 1 2 2 2 2

2600

760

770

970

970

1140

1140

840

820

960

960

2135

2900 2440

1970

2600

1250

1100

469

232

2135

577

382

2585

1920

577

2900

2135 622

2585

1920

2900

2135

1260

920

1016

992 856

1320

1292

1320

1292

1220

1192

1320

1015

1292

1220

1192

1320

1292 1015

1192 1292 1392

1155 1320

1292

382

1320

1292

494

1420

1170

1392

21

Amacan K Dimension table, discharge pipes Steel discharge pipes Overflow design B

Underfloor discharge C

OW 380 115-00

OW 380 113-00

Floor-mounted discharge D

Floor-mounted discharge D pressure--tight

OW 380 119-00

OW 380 117-00

b = to suit 22

b = to suit

Amacan K Main dimensions -- discharge pipes Pump sizes

all dimensions in mm

D

pipe dia.

A

DN2 min

DN2 max

H1 min

H3 min

700-330

711

700

650

300

600

1900

700-324/321

711

700

650

300

600

1900

800-370

813

800

700

400

700

2080

2850

800-380/381

813

800

700

400

700

2250

3020

1000-420/421

1016

1000

810

600

900

2520

3490

1000-500

1016

1000

810

600

900

2730

3700

1320

1300

960

1000

1300

3280

4660

1220

1200

910

900

1200

2930

4200

1320

1300

960

1000

1300

3280

1420

1400

1010

1100

1400

3640

1320

1300

960

1000

1300

1420

1400

1010

1100

1320

1300

960

1000

1200-540

1300-520 1300-750

Pump sizes

H1,H3 max

H2 min

H0 max

2570

670

7820

2570

670

7820

10000

770

7580

770

7410

(discharge pipes longer than 10,000 mm on request)

925

7040

925

6830

1130

6080

1080

6480

4660

1130

6080

5000

1180

5660

3110

4500

1130

6240

1400

3380

4800

1180

5920

1300

3420

4800

1130

5930

D

H4

M1

M2

M3

M4

N1

N2

N3

N4

700-330

711

500

800

1150

1160

1080

1160

910

455

695

700-324/321

711

500

800

1150

1160

1080

1160

910

455

695

800-370

813

550

900

1250

1260

1250

1260

1010

505

745

800-380/381

813

550

900

1250

1260

1250

1260

1010

505

745

1000-420/421

1016

650

1120

1460

1460

1450

1460

1210

605

855

1000-500

1016

650

1120

1460

1460

1450

1460

1210

605

855

1320

1000

1450

1760

1760

1700

1900

1510

755

1005

1220

930

1350

1670

1670

1600

1800

1410

710

960

1320

1000

1450

1760

1760

1700

1900

1510

755

1005

1420

1050

1550

1870

1870

1900

2040

1610

810

1060

1320

1000

1450

1760

1760

1700

1900

1510

755

1005

1420

1050

1550

1870

1870

1900

2040

1610

810

1060

1320

1000

1450

1760

1760

1700

1900

1510

755

1005

1200-540

1300-520 1300-750

Wall thickness against dia. D: -- up to size 800-380/381: 8 mm -- sizes 1000-420/421, 1000-500 with pipe diameter 1000 mm: 10 mm -- sizes 1000-500 with pipe diameter 1300 mm, 1200-540: 12 mm Discharge flanges to ISO 7005/2 / DIN 2501, PN 6 Admissible deviations for dimensions without tolerance indication: -- flange dimensions: ISO 2768 medium -- welding constructions: B/F to DIN EN ISO 13920

23

Amacan K Installation plan Installation example Installation mode BU

H geo

ha



X

View

Y

t4

D

Minimum water level d7

A -- A 100

Section

350

t2

t3

t1

Y

s 1/2 min

e1

p2

s 1 min

Recommended inflow direction

Foundation holes

p2

=100

=p1

s 1 min

0-45°

View X (without pump)

A

Foundation holes

OW 380 120--00

A Subject to technical modifications

24

Support plate -- discharge pipes

Amacan K all dimensions in mm

Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750

D*)

t2

t3

t4 min

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

330 330 330 410 435 480 480 585 585 1025 1025 940

200 200 200 250 250 300 300 350 350 400 400 480

1900 1900 2080 2250 2520 2730 3280 2930 3280 3570 3670 3740

D*)

s1 min

p1

p2

ha

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700

900 900 1000 1000 1220 1220 1550 1450 1550 1550 1650 1550

640 640 740 740 960 960 1260 1160 1260 1260 1360 1260

100 100 100 100 100 100 100 100 100 100 100 100

Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750

t4 max

10000 ((discharge g pipes longer than 10,000 , mm on request)

d7

e1

570 570 656 656 856 856 856 1015 1015 1155 1155 1170

430 430 480 480 600 600 750 700 750 750 800 750

*) from size 1000-500 onwards, D depends on motor size, see page 21 hü [m]

Allowances for sump dimensions to DIN 18202, part 4, group B

Head loss diagram H = Hgeo + hü + v2/2g v as a function of DA

Overflow head ”hü” dependent on Q and the design of outlet diam. DA. The characteristic curves only apply for discharge unobstructed on all sides; otherwise to be regarded as an approximation.

Q [m3/s]

OW 380 110--00

Overflow head hü

Amacan K 1300-750

Diagram for minimum water level t1

700-- 324/321

25

Amacan K Installation plan Installation example Installation mode CU

X

DN2 can be chosen with regard to the desired outlet speed. See table DN2min/DN2max and head loss diagram.

A

DN 2

t5

A

a

t4

H geo

Vent pipe

D

View

Y

Minimum water level d7

t2

t3

t1

Y

Section

e1

A -- A

s 1/2 min

250

300

200

s 1 min

View X (without discharge pipe cover, without pump)

Recommended inflow direction

Foundation holes

p1

a3 p2

0-45°

s 1 min

Foundation holes

a1

OW 380 121-00

Subject to technical modifications 26

200

a2

200

Support plate -- discharge pipe

Amacan K all dimensions in mm

Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750

D*)

t2

t3

t4 min

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

330 330 330 410 435 480 480 585 585 1025 1025 940

200 200 200 250 250 300 300 350 350 400 400 480

2570 2570 2850 3020 3490 3700 4660 4200 4660 5350 5550 5520

Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750

t4 max

10000 (discharge pipes longer than 10,000 mm on request) q )

d7

e1

s1 min

570 570 656 656 856 856 856 1015 1015 1155 1155 1170

430 430 480 480 600 600 750 700 750 750 800 750

1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700

D*)

p1

p2

DN2 min

DN2 max

a

a1

a2

a3

t5 min

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

860 860 960 960 1160 1160 1600 1500 1600 1600 1740 1600

960 960 1060 1060 1260 1260 1700 1600 1700 1700 1840 1700

300 300 400 400 600 600 1000 900 1000 1000 1100 1000

600 600 700 700 900 900 1300 1200 1300 1300 1400 1300

650 650 700 700 810 810 960 910 960 960 1010 960

1100 1100 1200 1200 1410 1410 1710 1620 1710 1710 1820 1710

850 850 950 950 1160 1160 1460 1370 1460 1460 1570 1460

430 430 480 480 580 580 730 685 730 730 785 730

670 670 770 770 925 925 1130 1080 1130 1130 1180 1130

*) from size 1000-500 onwards, D depends on motor size, see page 21 HV ges [m]

Allowances for sump dimensions to DIN 18202, part 4, group B

Head loss diagram H = Hgeo + HV ges HV ges includes: -----

elbow disch. pipe length = 5xDN2 check valve outlet loss v2/2g

OW 380 110--00

Q [m3/s]

Diagram for minimum water level t1

Amacan K 1300-750

700-- 324/321

27

Amacan K Installation plan Installation example Installation mode DU

DN2 can be chosen with regard to the desired outlet speed. See table DN2min/DN2max and head loss diagram.

X

DN 2

H4

-- not pressure sealed

t6

a

t7

A A

View

Y

t4

D

Vent pipe d7

Minimum water level

t2

t3

t1

Y Section

A -- A

s 1/2 min

250

300

p1

e1

p2

0-45°

200 OW 380 122-00

Subject to technical modifications 28

View X (without pump)

Foundation holes

s 1 min

Recommended inflow direction

s 1 min

200

Foundation holes

a1

a2

Support plate -- discharge pipe 200

Amacan K all dimensions in mm

Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750 Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750

D*)

t2

t3

t4 min

t4 max

d7

e1

s1 min

p1

p2

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

330 330 330 410 435 480 480 585 585 1025 1025 940

200 200 200 250 250 300 300 350 350 400 400 480

1250 1250 1430 1600 1765 1975 2180 1860 2180 2740 2840 2910

8680 8680 8580 8580 8275 8275 7520 7660 7520 7520 7420 7520

570 570 656 656 856 856 856 1015 1015 1155 1155 1170

430 430 480 480 600 600 750 700 750 750 800 750

1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700

860 860 960 960 1160 1160 1460 1360 1460 1460 1560 1460

960 960 1060 1060 1260 1260 1560 1460 1560 1560 1660 1560

D*)

DN2 min

DN2 max

a

a1

a2

t6 min

t6 max

H4

711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320

300 300 400 400 600 600 1000 900 1000 1000 1100 1000

600 600 700 700 900 900 1300 1200 1300 1300 1400 1300

650 650 700 700 810 810 960 910 960 960 1010 960

860 860 960 960 1160 1160 1460 1360 1460 1460 1560 1460

610 610 710 710 910 910 1210 1110 1210 1210 1310 1210

820 820 870 870 1075 1075 1480 1410 1480 1460 1530 1480

8250 8250 8020 7850 7585 7375 6820 7210 6820 6260 6110 6090

500 500 550 550 650 650 1000 930 1000 1000 1050 1000

t7 max

10000 ((discharge g pipes longer than 10,000 , mm on request)

*) from size 1000-500 onwards, D depends on motor size, see page 21 hV Kr [m]

Allowances for sump dimensions to DIN 18202, part 4, group B

Head loss diagram H= Hgeo + hV Kr + HV Anl Except for hV Kr all losses must be calculated with a view to plant conditions

OW 380 110--00

Q [m3/s]

Diagram for minimum water level t1

Amacan K 1300--750

700-- 324/321

29

Amacan K Pump with suspension wire and tensioning device in discharge pipe turnbuckle

Part list

59-8

59-17.2

Part No.

Part designation

Material

59-8 59-17.2 59-47 59-24

Turnbuckle Shackle Carrier cable Carrier cable to DIN 3088, form PK Spacer

1.4571 1.4571 1.4751

720

1.4401 EPDM

59-47

59-24 Cross-section of carrier cable arrangement (Where free cable length in discharge pipe exceeds 3.5 m, this arrangement is absolutely necessary)

Plastic hose for clamp

Carrier cable

59-24

Clamp

59-17.2

OW 380 091-00

Control cable

Spacer

Power supply cable

Cable length in discharge pipe exceeding 3.5 m: Mounting of tensioning device 59-8 -- closed discharge pipe: on the discharge pipe cover (see ill. above) -- open discharge pipe of installation mode BU on a girder above water level, to be supplied on site

OW 380 090-00

30

Cable length in discharge pipe under 3.5 m: On open discharge pipe: electrical cables must be mounted on a girder above water level (to be supplied on site) to avoid damages by the swirl of the water.

Amacan K Discharge pipe cover with cable duct Design variant: with welding sleeve Top view

Section

A -- A 3

A A

OW 380 836-00

1 2 3 4 5

2

5

4

1

5

Discharge pipe cover Cover Welding sleeve with input bushing acc. to DIN 22 419 with strain relief, protection against buckling and torsion Bracket for fixing turnbuckle (cable) Gasket, rubber reinforced with fabric

Note: Versions with split cover are possible, too.

31

Amacan K Discharge pipe cover with cable duct Design variant: with cable gland

Top view

View

X

X

2

A

3

A

Section

A -- A

OW 380 861-00

1 1 2 3 4 5 6 7 8

6

8

4

7

Discharge pipe cover Cable gland, type RGP (cable gland) Tecron modules (packing and filling) Cover segment with cable duct Sealing of the cover division with closed cell profile gasket, which may be pre-stressed by inserting an O-ring. Division guard Holding brackets for cover segment with cable glands Gasket, rubber reinforced with fabric

Note: Versions with split cover are possible, too.

32

5

Amacan K Selection table -- Example The following steps lead to a correct selection of pump:

Amacan K 800-381

980 1/min Laufradform Impeller type Forme de roue

Given data:

Capacity Q=400 l/s Head H=6m Liquid temp. t=30 °C Non-flameproof Material type G

A

145 x 135 mm Nr.

:

4 : 3 2 : 1 :

Q [ l/s ] H [m]

freier Durchgang free passage section de passage

D2A / D2I [mm] 408 / 378 398 / 344 384 / 317 367 / 295

H [m]

Impeller diameter

H [ft]

Förderhöhe Head Hauteur

With available QH data, the impeller diam. D2A is approx. 400 mm and thus Pduty can be found.

B

Pduty P [kW]

P2 min

The maximum value of the characteristic curve P through Pduty is the minimum motor power P2 min

C

Minimum motor power P2 min

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-381/...

Nr.

U or X

P2

(Flameproof)

kW

U tmax = 30

°C -

X tmax = 40

Motor size

°C

Irated

Istarting 1)

cos

j

d.o.l. A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia

mm2

mm

Weight Control cable 2) kg

24

.../266 U

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

730

28

.../286 U

60.0

250

0.78

2x4x4

16.6-18.7

A

780

37

.../376 U

77.0

335

0.78

2x4x6

17.8-19.8

A

870

45

.../456 U

92.0

460

0.79

2x4x10

21.7-23.7

A

930

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

730

28

.../376 X

61.0

335

0.75

2x4x4

16.6-18.7

A

870

37

.../456 X

77.0

460

0.77

2x4x6

17.8-19.8

A

930

45

.../646 X

106.0

600

0.69

2x4x10

21.7-23.7

A

1030

Motor size is to be selected by considering temperature and flameproof/ non-flameproof designs. Selected: Motor version ”U”, (non--flameproof), motor with 37.0 kW, 6--pole Designation of complete pump set: : Amacan K 800--381 / 376 U G For further data refer to the tables on pages 34-55 and motor documentation Amarex KRT Rh.-Nr. 2553.53/. . .-90 For a flameproof machine or tmax = 40 °C, motor .../45 6 X G should be used. Note : Impellers are trimmed to the operating point. The QH data should be clearly stated at the time of ordering, in order to define the exact impeller diameter.

33

Amacan K Amacan K 700-321

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 323 / 323 3 : 320 / 305 2 : 314 / 280 1 : 305 / 251

H [m]

105 x 115

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-321/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

A

Power supply cable Cross-section

Outside dia.

mm2

mm

Weight Control cable kg

U

18

.../206 U

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 30 °C

24

.../266 U

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

X

18

.../206 X

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 40 °C

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

34

Amacan K Amacan K 700-321

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 323 / 323 3 : 320 / 305 2 : 314 / 280 1 : 305 / 251

H [m]

105 x 115

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-321/...

Nr.

U or X

P2

(Flameproof)

kW

U

10

tmax = 30 °C X tmax = 40 °C

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

Power supply cable Cross-section

Outside dia.

Weight Control cable

mm2

mm

0.79

1x(12x2.5)

22.7--24.7

--

410

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

65

0.79

1x(12x2.5)

22.7--24.7

--

410

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

A

A

.../108 U

22.5

65

16

.../178 U

36.0

10

.../108 X

22.5

16

.../178 X

36.0

kg

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

35

Amacan K Amacan K 700-324

980 1/min Laufradform Impeller type Forme de roue

70 x 70

mm freier Durchgang free passage section de passage

Nr. : D2A / D2I [mm] 3 : 324 / 324 2 : 309 / 280 1 : 290 / 234

H [m] Förderhöhe Head Hauteur

H [ft]

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Förderstrom/Rate of Flow/Débit

Courbes selon ISO 9906/A.

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-324/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

A

Power supply cable Cross-section

Outside dia.

mm2

mm

Weight Control cable kg

U

18

.../206 U

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 30 °C

24

.../266 U

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

X

18

.../206 X

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 40 °C

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

36

Amacan K Amacan K 700-324

735 1/min Laufradform Impeller type Forme de roue

70 x 70 Nr. : D2A / D2I [mm] 3 : 324 / 324 2 : 309 / 280 1 : 290 / 234

H [m] Förderhöhe Head Hauteur

H [ft]

P [kW]

mm

freier Durchgang free passage section de passage

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-324/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

Power supply cable Cross-section

Outside dia.

mm2

mm

A

Weight Control cable kg

U

10

.../108 U

22.5

65

0.79

1x(12x2.5)

22.7-24.7

--

410

tmax = 30 °C

16

.../178 U

36.0

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

X

10

.../108 X

22.5

65

0.79

1x(12x2.5)

22.7-24.7

--

410

tmax = 40 °C

16

.../178 X

36.0

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on requestt

37

Amacan K Amacan K 700-330

980 1/min Laufradform Impeller type Forme de roue

70 x 92

Nr. : D2A / D2I [mm] 4 : 326 / 326 3 : 300 / 292 2 : 287 / 245 1 : 270 / 214

H [m] Förderhöhe Head Hauteur

H [ft]

P [kW]

mm

freier Durchgang free passage section de passage

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Förderstrom/Rate of Flow/Débit

Courbes selon ISO 9906/A.

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-330/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

A

Power supply cable Cross-section

Outside dia.

mm2

mm

Weight Control cable kg

U

18

.../206 U

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 30 °C

24

.../266 U

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

X

18

.../206 X

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

430

tmax = 40 °C

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

470

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

38

Amacan K Amacan K 700-330

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 326 / 326 3 : 310 / 310 2 : 295 / 266 1 : 278 / 231

H [m]

70 x 92

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.

Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

700-330/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

Power supply cable Cross-section

Outside dia.

mm2

mm

A

Weight Control cable kg

U

10

.../108 U

22.5

65

0.79

1x(12x2.5)

22.7-24.7

--

410

tmax = 30 °C

16

.../178 U

36.0

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

X

10

.../108 X

22.5

65

0.79

1x(12x2.5)

22.7-24.7

--

410

tmax = 40 °C

16

.../178 X

36.0

115

0.79

1x(7x4+5x1.5)

26.9--28.8

--

435

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

39

Amacan K Amacan K 800-370

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 370 / 370 3 340 / 340 2 : 318 / 303 1 : 300 / 278

H [m] Förderhöhe Head Hauteur

75

H [ft]

P [kW]

mm

freier Durchgang free passage section de passage

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.

Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-370/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight Control

cable 2) kg

18

.../206 U

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

505

U

24

.../266 U

48,.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

565

tmax = 30 °C

28

.../286 U

60.0

250

0.78

2x4x4

16.6--18.7

A

710

37

.../376 U

77.0

335

0.78

2x4x6

17.8--19.8

A

780

18

.../206 X

35.5

160

0.85

1x(7x4+5x1.5)

26.9--28.8

--

505

X

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

565

tmax = 40 °C

28

.../376 X

61.0

335

0.75

2x4x4

16.6--18.7

A

780

37

.../456 X

77.0

460

0.77

2x4x6

17.8--19.8

A

860

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm

40

Amacan K Amacan K 800-380

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 388 / 363 3 376 / 341 2 : 355 / 306 1 : 332 / 268

115 x 95

mm

freier Durchgang free passage section de passage

H [m]

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-380/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

A

Power supply cable Cross-section

Outside dia.

mm2

mm

Weight

Control cable 2) kg

28

.../286 U

60.0

250

0.78

2x4x4

16.6--18.7

A

780

U

37

.../376 U

77.0

335

0.78

2x4x6

17.8--19.8

A

870

tmax = 30 °C

45

.../456 U

92.0

460

0.79

2x4x10

21.7--23.7

A

930

64

.../646 U

139.0

600

0.75

2x4x16

27.1--30.1

A

1030

28

.../376 X

61.0

335

0.75

2x4x4

16.6--18.7

A

870

37

.../456 X

77.0

460

0.77

2x4x6

17.8--19.8

A

930

45

.../646 X

106.0

600

0.69

2x4x10

21.7--23.7

A

1030

X tmax = 40 °C

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ;

41

Amacan K Amacan K 800-380

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 388 / 363 3 376 / 341 2 : 355 / 306 1 : 332 / 268

115 x 95

H [m]

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-380/...

Nr.

U or X

P2

(Flameproof)

kW

U tmax = 30 °C X tmax = 40 °C

Irated

Istarting 1)

j

d.o.l.

Electric cables NSSHöu-J Power supply cable Cross-section

mm

0.79

1x(7x4+5x1.5)

26.9--28.8

150

0.75

1x(7x10+5x1.5)

230

0.73

2x4x4

36.0

115

0.79

.../218 X

44.0

150

.../338 X1

60.0

300

A

.../178 U

36.0

115

20

.../218 U

44.0

25

.../258 U1

57.0

16

.../178 X

20 25

Weight Control

cable 2) kg --

630

29.5--32.9

--

700

16.9-18.7

A

870

1x(7x4+5x1.5)

26.9--28.8

--

630

0.75

1x(7x10+5x1.5)

29.5--32.9

--

700

0.69

2x4x4

16.6-18.7

A

930

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2)Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

42

Outside dia.

mm2

A

16

cos

Amacan K Amacan K 800-381

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 408 / 378 3 398 / 344 2 : 384 / 317 1 : 367 / 295

145 x 135

H [m]

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-381/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight Control

cable 2) kg

24

.../266 U

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

730

U

28

.../286 U

60.0

250

0.78

2x4x4

16.6-18.7

A

780

tmax = 30 °C

37

.../376 U

77.0

335

0.78

2x4x6

17.8-19.8

A

870

45

.../456 U

92.0

460

0.79

2x4x10

21.7-23.7

A

930

24

.../266 X

48.5

225

0.84

1x(7x10+5x1.5)

29.5--32.9

--

730

X

28

.../376 X

61.0

335

0.75

2x4x4

16.6-18.7

A

870

tmax = 40 °C

37

.../456 X

77.0

460

0.77

2x4x6

17.8-19.8

A

930

45

.../646 X

106.0

600

0.69

2x4x10

21.7-23.7

A

1030

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

43

Amacan K Amacan K 800-381

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 408 / 378 3 : 398 / 344 2 : 384 / 317 1 : 367 / 295

145 x 135

H [m]

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

800-381/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

Electric cables NSSHöu-J

d.o.l.

A

Power supply cable Cross-section

Outside dia.

mm2

mm

A

Weight Control cable kg

U

16

.../178 U

36.0

115

0.79

1x(7x4+5x1.5)

26.9-28.8

--

630

tmax = 30 °C

20

.../218 U

44.0

150

0.75

1x(7x10+5x1.5)

29.5-32.9

--

700

X

16

.../178 X

36.0

115

0.79

1x(7x4+5x1.5)

26.9-28.8

--

630

tmax = 40 °C

20

.../218 X

44.0

150

0.75

1x(7x10+5x1.5)

29.5-32.9

--

700

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request

44

Amacan K Amacan K 1000-420

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 6 : 450 / 420 5 430 / 400 4 : 420 / 370 3 : 403 / 349 2 : 387 / 322 1 : 370 / 302

H [m]

126 x 100

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1000-420/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

Electric cables NSSHöu-J Power supply cable Cross-section

A

A

Outside dia.

mm2

mm

Weight

Control cable 2) kg

45

.../456 U1

92.0

460

0.79

2x4x10

21.7--23.7

A

1050

U

64

.../646 U1

139.0

600

0.74

2x4x16

27.1--30.1

A

1200

tmax = 30 °C

80

.../806 U1

158.0

740

0.81

2x4x25

32.8--35.8

A

1400

102

.../1026 U

200.0

1140

0.82

2x4x25

32.8--35.8

A

1550

45

.../646 X1

105.0

600

0.69

2x4x10

21.7--23.7

A

1200

X

64

.../806 X1

131.0

740

0.77

2x4x16

27.1--30.1

A

1400

tmax = 40 °C

80

.../1026 X

158.0

1140

0.80

2x4x25

32.8--35.8

A

1550

102

.../1206 X

200.0

1450

0.79

2x4x25

32.8--35.8

A

1650

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

45

Amacan K Amacan K 1000-420

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 6 : 450 / 420 5 430 / 400 4 : 420 / 370 3 : 403 / 349 2 : 387 / 322 1 : 370 / 302

H [m]

126 x 100

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.

Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1000-420/...

Nr.

U or X

P2

(Flameproof)

kW

U tmax = 30 °C X tmax = 40 °C

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Control cable 2) kg

25

.../258 U2

57.0

230

0.73

2x4x4

16.6--18.7

A

1000

33

.../338 U2

72.0

300

0.75

2x4x6

17.8--19.8

A

1050

43

.../438 U

100.0

460

0.70

2x4x10

21.7--23.7

A

1150

25

.../338 X2

59.0

300

0.70

2x4x4

16.6--18.7

A

1050

33

.../438 X

85.0

460

0.64

2x4x10

21.7--23.7

A

1150

43

.../548 X

105.0

560

0.66

2x4x10

21.7--23.7

A

1200

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm

46

Weight

Amacan K Amacan K 1000-421

980 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 450 / 415 3 434 / 386 2 : 416 / 356 1 : 396 / 324

H [m]

140 x 150

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1000-421/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight

Control cable 2) kg

37

.../376 U1

77.0

335

0.78

2x4x6

17.8--19.8

A

1010

U

45

.../456 U1

92.0

460

0.79

2x4x10

21.7--23.7

A

1050

tmax = 30 °C

64

.../646 U1

139.0

600

0.74

2x4x16

27.1--30.1

A

1200

80

.../806 U1

158.0

740

0.81

2x4x25

32.8--35.8

A

1400

37

.../456 X1

77.0

460

0.77

2x4x6

17.8--19.8

A

1050

45

.../646 X1

105.0

600

0.69

2x4x10

21.7--23.7

A

1200

64

.../806 X1

131.0

740

0.77

2x4x16

27.1--30.1

A

1400

X tmax = 40 °C

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm

47

Amacan K Amacan K 1000-421

735 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 450 / 415 3 434 / 386 2 : 416 / 356 1 : 396 / 324

140 x 150

H [m]

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1000-421/...

Nr.

U or X

P2

(Flameproof)

kW

U tmax = 30 °C

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight

Control cable 2) kg

25

.../258 U2

57.0

230

0.73

2x4x4

16.6--18.7

A

1000

33

.../338 U2

72.0

300

0.75

2x4x6

17.8--19.8

A

1050

43

.../438 U

100.0

460

0.70

2x4x10

21.7--23.7

A

1150

19

.../258 X2

46.0

230

0.68

2x4x4

16.6--18.7

A

1000

X

25

.../338 X2

59.0

300

0.70

2x4x4

16.6--18.7

A

1050

tmax = 40 °C

33

.../438 X

85.0

460

0.64

2x4x10

21.7--23.7

A

1150

43

.../548 X

105.0

560

0.66

2x4x10

21.7--23.7

A

1200

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm

48

Amacan K Amacan K 1000-500

980 1/min

(applies to Amacan K 1300-500, too)

Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 4 : 508 / 508 3 460 / 460 2 : 448 / 412 1 : 430 / 350

H [m]

145 x 110

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.

Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1000-500/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

Electric cables NSSHöu-J Power supply cable Cross-section

A

A

Outside dia.

mm2

mm

Weight

Control cable 2) kg

80

.../806 U1

158.0

740

0.81

2x4x25

32.8--35.8

A

1470

102

.../1026 U

200.0

1140

0.82

2x4x25

32.8--35.8

A

1630

U

120

.../1206 U

230.0

1450

0.82

2x4x35

36.9--39.9

A

1750

tmax = 30 °C

138

.../1386 U

245.0

1750

0.87

2x4x35

36.9--39.9

B

2050

165

.../1656 U

285.0

1670

0.89

2x4x50

42.9--45.9

B

2200

200

.../2006 U

345.0

2400

0.91

2x3x70/35

48.4--51.4

B

2350

80

.../1026 X

158.0

1140

0.80

2x4x25

32.8--35.8

A

1630

102

.../1206 X

200.0

1450

0.80

2x4x25

32.8--35.8

A

1750

120

.../1386 X

215.0

1750

0.87

2x4x35

36.9--39.9

B

2050

138

.../1656 X

240.0

1670

0.89

2x4x35

36.9--39.9

B

2200

165

.../2006 X

258.0

2400

0.90

2x4x50

42.9--45.9

B

2350

X tmax = 40 °C

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

49

Amacan K Amacan K 1200-540

980 1/min

(applies to Amacan k 1300-540 and 1400-540, too)

Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380

H [m]

133 x 150

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1200-540/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight

Control cable 2) kg

165

.../1656 U

285.0

1670

0.89

2x4x50

42.9--45.9

B

3000

U

200

.../2006 U

345.0

2400

0.91

2x3x70/35

48.4--51.4

B

3150

tmax = 30 °C

260

.../2606 U

450.0

1920

0.89

2x3x95/50

55.0--59.0

B

3550

320

.../3206 U

590.0

3700

0.83

4x4x50

42.9--45.9

B

3750

165

.../2006 X

285.0

2400

0.90

2x4x50

42.9--45.9

B

3150

200

.../2606 X

345.0

1920

0.88

2x3x70/35

48.4--51.4

B

3550

260

.../3206 X

470.0

3700

0.84

4x4x35

36.9--39.9

B

3750

X tmax = 40 °C

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

50

Amacan K Amacan K 1200-540

735 1/min

(applies to Amacan K 1300-540, too)

Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380

H [m] Förderhöhe Head Hauteur

133 x 150

mm

freier Durchgang free passage section de passage

H [ft]

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Irated

Istarting 1)

Motor

Motor

Amacan K

Code

design

rating

1200-540/...

Nr.

U or X

P2

(Flameproof)

kW 84

.../848 U

177.0

680

U

107

.../1078 U2

225.0

1000

tmax = 30 °C

126

.../1268 U2

240.0

150

.../1508 U2

285.0

84

.../1078 X2

X

107

tmax = 40 °C

126 150

cos

j

d.o.l.

Electric cables NSSHöu-J Power supply cable

Weight

Control cable 2)

Cross-section

Outside dia.

mm2

mm

0.77

2x4x25

32.8--35.8

A

2400

0.76

2x4x35

36.9--39.9

A

2500

1220

0.83

2x4x35

36.9--39.9

B

2910

1400

0.82

2x4x50

42.9--45.9

B

3100

199.0

1000

0.67

2x4x25

32.8--35.8

A

2500

.../1268 X2

205

1220

0.82

2x4x35

36.9--39.9

B

2910

.../1508 X2

250.0

1400

0.80

2x4x50

42.9--45.9

B

3100

.../1808 X2

275.0

1700

0.85

2x4x50

42.9--45.9

B

3210

A

A

kg

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

51

Amacan K Amacan K 1200-540

590 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380

H [m]

133 x 150

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1200-540/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Weight

Control cable 2) kg

43

.../4310 U1

99.0

380

0.68

2x4x10

21.7--23.7

A

2250

U

54

.../5410 U2

121.0

420

0.71

2x4x16

27.1--30.1

A

2350

tmax = 30 °C

67

.../6710 U2

149.0

540

0.71

2x4x16

27.1--30.1

A

2450

84

.../8410 U2

189.0

680

0.70

2x4x25

32.8--35.8

A

2550

43

.../5410 X2

102.0

420

0.67

2x4x10

21.7--23.7

A

2350

X

54

.../6710 X2

125.0

540

0.68

2x4x16

27.1--30.1

A

2450

tmax = 40 °C

67

.../8410 X2

159.0

680

0.66

2x4x25

32.8--35.8

A

2550

84

.../10710 X2

185.0

980

0.70

2x4x25

32.8--35.8

B

2900

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm

52

Amacan K Amacan K 1300-520

735 1/min

(applies to Amacan K 1400-520, too)

Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 5 : 612 / 532 4 : 600 / 505 3 : 585 / 487 2 : 570 / 460 1 : 560 / 435

H [m]

145

mm

freier Durchgang free passage section de passage

H [ft]

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1300-520/...

Nr.

U or X

P2

(Flameproof)

kW

Irated

Istarting 1)

cos

j

d.o.l.

Electric cables NSSHöu-J Power supply cable Cross-section

A

A

Outside dia.

Weight

Control cable 2)

mm2

mm

2x4x35

36.9--39.9

B

3050

kg

126

.../1268 U1

235

1220

0.84

U

150

.../1508 U1

290

1400

0.82

2x4x50

42.9--45.9

B

3200

tmax = 30 °C

180

.../1808 U1

335

1700

0.84

2x3x70/35

48.4--51.4

B

3350

225

.../2258 U1

425

2650

0.83

2x3x95/50

55.0--59.0

B

3900

126

.../1508 X1

245

1400

0.81

2x4x35

36.9--39.9

B

3200

X

150

.../1808 X1

275

1700

0.85

2x4x50

42.9--45.9

B

3350

tmax = 40 °C

180

.../2258 X1

355

2650

0.80

2x3x70/35

48.4--51.4

B

3900

225

.../2808 X1

445

3420

0.78

2x3x95/50

55.0--59.0

B

4250

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

53

Amacan K Amacan K 1300-520

590 1/min Laufradform Impeller type Forme de roue

Nr. : D2A / D2I [mm] 5 : 612 / 532 4 : 600 / 505 3 : 585 / 487 2 : 570 / 460 1 : 560 / 435

H [m]

145

H [ft]

mm

freier Durchgang free passage section de passage

Förderhöhe Head Hauteur

P [kW]

P [hp]

Leistungsbedarf Power Input Puiss. hyd. abs.

Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit

400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor

Motor

Amacan K

Code

design

rating

1300-520/...

Nr.

U or X

P2

(Flameproof)

kW

U tmax = 30 °C X tmax = 40 °C

Irated

Istarting 1)

cos

j

d.o.l.

A

A

Electric cables NSSHöu-J Power supply cable Cross-section

Outside dia.

mm2

mm

Control cable 2) kg

67

.../6710 U1

149

540

0.71

2x4x16

27.1--30.1

A

2650

84

.../8410 U1

189

680

0.70

2x4x25

32.8--35.8

A

2750

107

.../10710 U1

220

980

0.75

2x4x35

36.9--39.9

B

3000

67

.../8410 X2

159

680

0.66

2x4x25

32.8--35.8

A

2750

84

.../10710 X2

185

980

0.70

2x4x25

36.9--39.9

B

3000

107

.../12610 X2

205

1070

0.82

2x4x35

36.9--39.9

B

3200

Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm

54

Weight

Amacan K Hydraulic data of pump sizes

-- 1300--750 on request

55

Amacan K Order detail -- carrier cable length In order to select the proper length of the carrier cable, it is absolutely necessary to define dimension ”L”.

mm

-

lower edge of pit = lower edge of pump

KSB Aktiengesellschaft P.O. Box 200743 · 06008 Halle (Saale) · Turmstraße 92 · 06110 Halle (Germany) Tel. +49 (345) 48 26 0 · Fax +49 (345) 48 26 46 99 · www.ksb.com

1579.5/3--10

10/97

L=

Subject to modification without notice

suspension at the cover or with BU / BG / A at a support

L

-

Related Documents

Sewage Pump Amacan
December 2019 5
Sewage Pump
May 2020 2
Drainage Pump Amacan
December 2019 0
Pump
November 2019 31
Pump
May 2020 16