Amacan K
Baureihenheft 1579.5/3--10
Applications
Sewage pumps, mixed water pumps and activated sludge pumps in sewage treatment plants, irrigation and drainage pumping stations. Storm water pumps for flood protection, water pollution control and industrial refuse tip effluents, for pumping all pre--screened or pre--settled media not liable to twist.
Submersible motor pump with channel-type impeller for installation in discharge pipes
Operating data Heads Capacity -- standard programme : -- custom--made programme : Motor power Product temperature: max. submersion level:
H up to
30 m
Q up to 1000 l/s Q up to 2000 l/s P2 up to 320 kW up to 40 °C 20 m
Design Wet installed, close--coupled pump with channel--type impeller, single--stage, single--entry, for installation in discharge pipes.
Drive Three-phase asynchronous motor, winding acc. to IEC 38 for 400/690V supply voltage (also suitable for 380 V and 415 V mains), enclosure type 58 to IEC 34-5/IP 68 to DIN 40050, motor design to VDE 0530 part 1/IEC 34--1, insulation class F, for flameproof units also VDE 0171/5.78 parts 1 and 5/ EN 50014/EN 50018, protection type EEx d IIB T3.
Bearings -- up to motor sizes 646, 548 : grease lubricated, maintenance--free anti--friction bearings -- up to motor sizes 806, 678, 4310 : grease lubricated anti--friction bearings, re--lubrication without dismantling the pumpset.
Shaft sealing
OW 380 092-00
Shaft sealing is effected by means of two elastomer bellows mechanical seals in tandem arrangement, independent of the direction of rotation. A liquid chamber filled with environment--friendly non--toxic paraffin oil between the seals ensures cooling and lubrication.
Automation products available: · PumpExpert · Hyamaster · hyatronic
Designation Amacan
K 800-380 / 64 6 U X
Pump type Channel type impeller DN of discharge pipe [mm] Impeller diameter [mm] Motor power P2 in kW
(only correct for U motor designs)
Number of poles in the motor Motor design Material code
U/U1/U2 = product temperature 30 °C X/X1/X2 = flameproof, product temperature 40°C G = grey cast iron G1= grey cast iron with variants G3= sea water design
G
Materials
Pump casing GG-25 Motor housing GG-25 Pump shaft C 45 N Shaft prot. sleeve 1.4021.05 Impeller GG-25/Noridur â Nuts and bolts A 4/1.4462 Casing wear ring GG-25/VG 434 Cathodic corrosion protection available
Amacan K Selection chart 50 Hz
H [m]
Q [l/s] Q [m3/h]
Standard programme Custom--made programme
2
Amacan K Range chart 60 Hz
H [m]
Q [l/s] Q [m3/h]
3
Amacan K Product advantages to the benefit of our customers
Cable mounted with strain relief.
Especially designed lug for receiving crane hook allows installation and removal even when inlet chamber is flooded. (No need to enter the pit!)
The cable entry is completely watertight with insulation at several points: 1. Long rubber gland 2. Cable embedded in cast resin 3. Conductors embedded in cast resin 4. Soldered strands Even in the event of damage to the cable and core insulation there is no possibility of moisture entering the motor chamber along the strands due to capillary action.
Increased efficiency thanks to motor shaft made of ferromagnetic steel Operationally safe, dry, three-phase asynchronous motor, surface cooled, in acc. with VDE regulations (from the KSB submersible pump range) Thermal protection prevents motor from overheating Early fault detection by means of bearing temperature monitoring (from motor /286 and /258 onwards) Inspection ports for separate functional test of mechanical seals
Patented, standard moisture sensor as additional safety device. Motor housing with stator removable after loosening the flange connections (simple visual inspection of the motor)
Mechanical seals in tandem arrangement, trouble-free operation guaranteed for many years due to a common liquid feed with large air cushion for expansion and high quality, wear-resistant sealing materials. Shaft sleeve protects the pump shaft against corrosion
Mechanical seal monitored by means of float switch in the leakage chamber
Two- or three-channel impeller with large free passage
High operational safety due to protected sealing chamber. Renewable casing wear ring protects casing against wear OW 380 109-00
Self-centering positioning of the pump in the discharge column by its own weight. Sealing ensured by an O-ring. No additional anchoring or rotational protection required. Fast installation and removal of pump as disconnection of pipes and cables is not necessary.
The illustration shown corresponds to Amacan K 1000--420
4
Amacan K Table of Contents
Programme and scope of supply, order data, general comments
Page 6
Table of pumped media, impeller types
Page 7
Modes of installation
Page 8
Technical data, warranty, testing and quality assurance, operation with frequency converter, materials, coating
Pages 9 -- 12
Connection of monitoring equipment
Pages 13
General drawings
Pages 14 -- 17
Mechanical seal -- detail
Pages 18 -- 19
Dimension tables -- pump/discharge pipe
Pages 20 -- 23
Installation plans
Pages 24 -- 29
Pump with suspension wire and turnbuckle in discharge pipe, discharge pipe cover with cable entry
Pages 30 -- 32
Selection table -- example
Page 33
Characteristic curves
Pages 34 -- 55
For further motor data refer to motor documentation: Amarex KRT Reference-No. 2553.53/...-90
5
Amacan K Programme Standard pump programme : pumpsets up to sizes 1200-540, n = 980 1/min as described in this brochure Custom-made programme : pumpsets from size 1200-540 on, n = 980 1/min, motor power P2 > 200 kW with various drives. Hydraulic data on request.
Scope of supply Basic version :
pump unit complete and ready for installation, 400 V / 50 Hz, supplied with10 m power cable, without performance test (deviations from the basic version will result in extra charges and longer delivery period).
Accessories available / required: -- steel discharge pipes in various designs -- lifting rope complete with cable protection (obligatory from 3.5 m of free cable length in the discharge pipe onwards) -- monitoring unit
General comments Our pump units comply with enclosure type IP 68 in accordance with DIN 40050 and therefore include the lesser requirements of IP 58 of IEC 34--5 valid since April 1, 1988. During production the pumps and motors are subjected to functional tests both independently and as a unit. Head and power rating apply only to pumped liquids with a density of ρ = 1 kg/dm3 and kinematic viscosity ν up to 20 mm2/s. Motor ratings P2 should have a safety factor which is adequate for a particular pumping application (see selection example on page 33). To facilitate transportation the electrical cabling will be supplied separately from cross--sectional area 4x50 mm2 upwards. Applicable drawing numbers are indicated below the drawings.
Order data --------
6
Designation of pump unit according to ”Designation” / ”Selection of pump” Capacity Q Total head H (Hgeo and plant losses) Liquid handled and liquid temperature Voltage, frequency, starting method, length of cable Accessories required -- (for discharge pipes, please indicate installation mode and relevant levels) Quantity and language of operating instructions
Amacan K List of liquids handled The application of submersible pumps is versatile and subject to local conditions which are distinct from case to case. The following list serves as recommendation only! For profound counselling in all questions of planning, consult your nearest KSB sales agency or our technical divisions. Liquid handled 1)
The end user should decide whether flameproof motors are necessary
Dirty water River water Rain water Sewage Activated sludge
Indication, recommendation
free impeller passage, larger than solids occuring prescreened p esc ee ed or o pre--settled p e se ed if necessary ecessa y max. 3% dry substance content material combination G3, tmax = 30 °C, anode check every 6 months
Sea water Industrial effluent, contaminated with ... -- paint suspension -- varnish suspension -- fibrous material -- abrasive material Industrial effluent, slightly acid
free of solvents, refer to operator’s instructions! free of solvents, for silicon--free version consult KSB short fibres, not liable to twist variant ”G1” 3) - 0.5 g/l max. solids content ph-Wert ³ 6 variant ”G1” 3) plus INERTOL POXITAR coating
Chemically neutral waste water -- ammonia water -- ammonia hydroxide 5% NH4OH -- urea 25% (NH2)2-CO -- potassium hydroxide 10% KOH -- calcium hydroxide 5% Ca(OH)2 -- sodium hydroxide 5% NaOH -- sodium carbonate 30% Na2CO3 Chemically neutral waste water contaminated with ... -- aliphatic hydrocarbons e.g. oils, petrol, butane, methane
with polyamide cable sheath or Tefzel cable 2)
-- aromatic hydrocarbons e.g. benzene, styrene
FPM (VITON) O-rings and TEFZEL cable 2)
-- chlorinated hydrocarbons e.g. trichlorethylene, ethylene chloride, chloroform, methylene chloride
FPM (VITON) O-rings and TEFZEL cable 2)
1) Liquids not mentioned here require in most of the cases upgraded materials. Please consult KSB. 2) Modified fluoropolymer ETFE, standard variant (page 10 und 11) to be ordered separately 3) Standard variant (page 12) to be ordered separately
Impeller type Closed channel--type impeller (K impeller) for contaminated non--gaseous liquids containing solids, not liable to twist
Note:
K-impellers are trimmed to meet the exact duty point.
7
Amacan K Types of installation
OW 380 086--00
BU
Steel discharge pipe overflow design
OW 380 088--00
CU
OW 380 089--00
DU
Steel discharge pipe with floor-mounted discharge nozzle
Inclined installation on request.
8
Steel discharge pipe with underfloor discharge
OW 380 087--00
CS
Design variant of installation mode CU, under installation cover in floor, foot--mounted (on request)
Amacan K Technical data Size
Pipe dia. req. [mm]
n [1/min]
Impeller no. of blades
Free passage [mm] 70x92
Standard programme 700-330
700
735
3
700-330
700
980
3
70x92
700-321
700
735
2
105x115
700-321
700
980
2
105x115
700-324
700
735
3
70
700-324
700
980
3
70
800-370
800
980
3
75
800-380
800
735
3
115x95
800-381
800
735
2
145x135
800-380
800
980
3
115x95
800-381
800
980
2
145x135
1000-420
1000
735
3
126x100
1000-421
1000
735
2
140x150
1000-420
1000
980
3
126x100
1000-421
1000
980
2
140x150
1000-500
1000/1300 *
980
3
145x110
1200-540
1200
590
3
133x150
1200-540
1200/1300 *
735
3
133x150
1200-540
1300
980
3
133x150
Custom--made programme 1200-540
1400
980
3
133x150
1300-520
1300
590
3
145
1300-520
1300/1400 *
735
3
145
1300-750
1400
490
3
180
1300-750
1300/1400
590
3
180
*) depending on the motor size (see page 21)
9
Amacan K Technical data -- Pumpset K 700-330 K 700-324/321 K 800-370 K 800-380/381
Pump sizes
K 1000-420/421 K 1000-500 K 1200-540 K 1300-520 K 1300-750
Characteristics Motor versions :
6 - pole
20 6
26 6
28 6 ... 64 6
80 6 ... 120 6
138 6 ... 200 6
260 6 ... 320 6
U = non-flameproof
8 - pole
10 8; 17 8
21 8
25 8 ... 54 8
67 8 ... 107 8
126 8 ... 180 8
225 8 ... 280 8
43 10 ... 84 10
107 10 ... 170 10
215 10 ... 270 10
X = flameproof
10 - pole
mechanical
12 - pole
132 12 ... 200 12
Typical sectional drawing / motor size DKN
p.14 161; 181
Shaft sealing pump -- motor
2 bellows mech. seals, independent of direction of rotation, in tandem arrangement
Anti-friction bearing with re-lubrication facility Typical mech. seal detail p. .18/19
p.15 225
p.16 280
-
ill. 1 OW 309 124-00
ill. 2 OW 309 110-00
1
Enclosure
Pressure-tight enclosure IP 58 to IEC 34-5/IP 68 to DIN 40050 VDE 0171/1.69 0171/5.78 EN50014/50018
----
(Ex) dll G3 VDE 0171/1.69
-
-
-
Windings for 400V/50 Hz mains (suitable for 380 ... 415 V)
elektrical
230 V
400 V delta ; 690 V star
----
1 with special winding
500 V
1
690 V
1
with special winding
`
Starting mode
d.o.l. or star--delta
Motor cooling
by surrounding pumped liquid, S 1 operation
-
Cable length > 10 m Cable entry
1 (> 50m `)
U;X
resin filled cable gland (for cross sectional area 4 x 35 mm2)
Polyamide cable sheath TEFZEL 1) cable (waterproof over full length) Operated with frequency inverter 2) modified fluoropolymer ETFE see page 11
10
star connected
with standard winding star connected
other voltages
Cable length 10 m
1) 2)
`
----
Insulation class F
Windings for mains voltage
---355
----
Elastomers in Viton (for O-Rings and mech. seal)
Explosion protection
p.17 315
----
1 `
1 - = standard 1 = standard design variant
(flameproof version `) ` = special version ---- = not available
Amacan K Technical data -- Pumpset K 700-330 K 700-324/321 K 800-370 K 800-380/381
Pump sizes
K 1000-420/421 K 1000-500 K 1200-540 K 1300-520 K 1300-750
Characteristics Motor versions :
6 - pole
20 6
26 6
28 6 ... 64 6
80 6 ... 120 6
138 6 ... 200 6
260 6 ... 320 6
U = non-flameproof
8 - pole
10 8; 17 8
21 8
25 8 ... 54 8
67 8 ... 107 8
126 8 ... 180 8
225 8 ... 280 8
43 10 ... 84 10
107 10 ... 170 10
215 10 ... 270 10
X = flameproof
10 - pole
Monitoring page 13
Operating limits
12 - pole
132 12 ... 200 12
max. permissible submersion level
U
25 m
X
20 m
Pumped liquid temperature
U
30 °C
X
40 °C
U
automatic on/off when permissible winding temp. has been reached (control circuit)
temperature control of the winding
X
2 separate control circuits
---
automatic on/off control when permissible winding temp. has been reached (control circuit) trip control when the flameproof temperature limit has been reached (limitation circuit)
Temp. control of pump-side anti--friction bearings (PT 100)
----
Moisture electrode in the motor housing
`
-
----
-
Float switch in the leakage chamber to monitor mech. seal
- = standard 1 = standard design variant
-
`
` = special version ---- = not available
Warranty, tests and quality assurance Every pump is subjected to a functional test. We grant a warranty for pump performance(non--witnessed) in line with ISO 9906/A or similar/equivalent international standards. Witnessed performance test in acc. with ISO or equivalent standards possible. The high quality of our pumps is ensured by constant quality checks.
Frequency inverter operation Only 95 % of the motor power P2 must be utilized. For flameproof units, only thermistor tripping devices with PTB approval must be used. Observe the exception on page 13 (ill. 1).
11
Amacan K Materials Material combinations
G
G3 1) (Sea water version)
G1
Part No.
Designation
101
Pump casing
GG-25
113
Intermediate casing
GG-25
138
Inlet nozzle 2)
GG-25
163
Discharge cover
230
Impeller
350
Bearing housing
360
Bearing cover
Materials
3)
GG-25 9.4460 4)
GG-25
GG-25 GG-25 NBR
5)
Viton 6)
412
O--ring NBR
421
Shaft seal ring NBR
433.01
Mechanical seal
Carbon / cast chrome
433.02
Mechanical seal
Silicon carbide / silicon carbide
502
Casing wear ring
524
Shaft protecting sleeve
571
Lifting lug
811
Motor housing
GG-25
812
Motor housing cover
GG-25
818
Shaft (rotor): up to motor DKN 161/181
Cable entry
div.
Bolts
99-16
Anode
818
Shaft (rotor)
1) 2) 3) 4) 5) 6) 7) 8)
GG-25
VG 434 ST 37 7)
1.4021.05
1.4057 C 45 N
8)
GG 1.4462 / 1.4571 ----
Zn C 45 N
Standard surface coating Primer and final coat Surface treatment: SA 2 1/2 (SIS 055900) AN 1865 Corrosion prevention to AA 0080-06-01 Primer: iron oxide (dipped) 0.035 mm to 0.040 0.0m Top coat: KSB standard coating, approx.0.070 mm (RAL 5002)
Standard design variant: -- sea water version: Primer and INERTOL POXITAR Surface treatment see standard Primer: see standard + wash primer INERTOL POXITAR, approx. 0.250 mm (2-component epoxy-tar coating) Top coat:
Special surface treatment Available at extra charge and longer delivery periods 12
VG 434
1.4021.05
Pump units with cathodic protection: check anode every 6 months for pump sizes 1300--520 and 1300--750 for pump size 700--330 Noridur Nitrile (Perbunan) Fluororubber FPM Lifting lug in 1.4462 dry shaft in the pump area (shaft-protecting sleeve in chromium steel)
Standard:
Viton 6)
NBR 5)
Shaft (rotor): from motor DKN 225 on 834.1/.2
9.4460 4)
Amacan K Connection of monitoring equipment Thermal motor monitoring for range of capacity > 4 kW to 30 kW 21
22
10
bimetal
11
Motor version ”U” and ”W” (non-flameproof)
Motor version ”X” and ”Y” (flameproof)
21
22
Connected directly into the control circuit of motor contactor
21
22
Connected directly into the control circuit of motor contactor
10
11
Not required, if supplied connect to dummy terminal
10
11
Connected via thermistor tripping with manual reset
PTC
Ill 1
Thermal motor monitoring for all other Amacan K sizes
20
21
10
bimetal
11
Non-flameproof ”U”
Flameproof ”X”
20
21
Not required, if supplied connect to blank terminal
20
21
Connected directly into the control circuit of the motor contactor 2)
10
11
Connected via thermistor tripping device with automatic reset
10
11
Connected via thermistor tripping device with manual reset 1)
PTC
Ill 2
Thermal monitoring of pump-side ball bearing 15
Moisture detection probe in motor housing
16
Connected via PT100 tripping relay e.g. make Kriwan type PT100--2AV Ill 3
3
9
16
9
Connected to earth leakage circuit breaker, nominal current leakage 30--50 mA
4
float switch
moisture sensor
PT100
15
Mechanical seal monitoring via float switch
3
4
Connected for alarm, i.e. switch off
Ill 4
Ill 5
1)
For inverter operation with flameproof requirements, PTB--approved tripping devices are required, e.g. make Siemens type 3UN6 with manual reset. 2) KSB tripping device available with both functions 20
21
= identity of conductor
Bi-Metall / PTC = temperature sensor in the winding
13
Amacan K Sectional drawing typical for sizes < 4 kW to 30 kW 571 914.26 920.26 550.26 529 322 932.01 421.01 811/81-59
932.03
818
321.02 914.02 412.02 441
834 914.04
412.03
412.07
330 932.02
81-17
903
900.28
411.03 81-56
903.15
81-44.28 81-18 99-17 902.01 920.01 412.04 113 433.01 433.02 412.20
260
0W 383650-00
914.10
940.03
101
502
230
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
101
Pump casing
421
Lip seal
818
Rotor
113
Intermediate casing
433
Mechanical seal
834
Cable duct
230
Impeller
502
Casing wear ring
900
Bolt
260
Impeller hub cap
529
Bearing sleeve
902
Stud
321
Radial ball bearing
550
Disc
903
Screw plug
322
Radial roller bearing
571
Lug
914
Socket head cap screw
330
Bearing bracket
81-17
Cable crimp
920
Nut
411
Joint ring
81-18
Cable socket
932
Circlip
412
O-ring
81-56
Moisture protection of motor
99-17
Desiccant
14
Amacan K General arrangement drawing Amacan K 800-370 to 1000-420/421 , motors 28 6 to 54 8 550.25
901.25 550.25
920.25
81-97.2 59-71
68-3.2
571
901.26
914.01 500.04 412.01
322 932.01
812 421.01 500.01 80-1
81-22 81-56
818 360
81-45 411.26
321 901.01 550.02 550.01 932.02 412.02
99-17 914.02 412.09 914.06
433.01 903.03 433.02 411.03 412.05
421.02 500.02 350
903.04 411.04
903.5 411.05 412.04 902.01 920.01 113 411.06
OW 380 103-00
550.23 412.06
931.01
901.21
940.03
260
502
230
101
412.20
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
101
Pump casing
421
Lip seal
81-56
Moisture protection of motor
931
Lock washer
113
Intermediate casing
433
Mechanical seal
81-97
Cable protector
932
Circlip
230
Impeller
500
Ring
812
Motor casing cover
940
Key
260
Impeller hub cap
502
Casing wear ring
818
Rotor
99-17
Desiccant
321
Radial ball bearing
550
Disc
834
Cable duct
322
Radial roller bearing
571
Lug
901
Hexagon bolt
350
Bearing housing
68-3
Cover plate
902
Stud
360
Bearing cover
80-1
Semi-finished motor
903
Screw plug
411
Joint ring
81-22
Terminal box cover
914
Socket head cap screw
412
O-ring
81-45
Float switch
920
Nut
15
Amacan K General arrangement drawing Amacan K 1000-420/421 to 1300-520 , motors 80 6 to 84 10 Amacan K 1300-520 with inlet nozzle (Part No. 138)
550.25
A -- A
901.25 550.25
920.25
81-97.2
68-32
59-71
571 901.26
812 914.01
903.01 411.01 636.01
412.01 500.04 322
500.01 520.01 80-1
932.01 421.01
818 360 500.03
412.09
647
81-22
320 901.01 550.02 932.02
421.03
550.01
500.05
500.02
81-56
350
914.06
903.03 411.03 636.02 903.02 411.02 903.04 411.04
412.02 914.02 99-17 412.03 81-45 421.02 411.26 903.05 411.05 902.01 920.01 412.04 412.05 113 411.06 433.01 433.02
OW 380 104-00 230 412.20
940.03 931.01 412.06 502 101
550.23 901.21
260
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
101 113 230 260 320 322 350 360 411 412
Pump casing Intermediate casing Impeller Impeller hub cap Anti--friction bearing Radial roller bearing Bearing housing Bearing cover Joint ring O-ring
421 433 500 502 520 550 571 636 647 68-3
Lip seal Mechanical seal Ring Casing wear ring Sleeve Disc Lug Grease nipple Grease regulator Cover plate
80-1 81-22 81-45 81-56 81-97 812 818 901 902 903
Semi-finished motor Terminal box cover Float switch Moisture protection of motor Cable protector Motor casing cover Rotor Hexagon bolt Stud Screw plug
914 9
S Socket head cap p screw
920 931 932 940 99-17
Nut Lock washer Circlip Key Desiccant
16
Amacan K General arrangement drawing Amacan K 1000-500 to 1300-520 , motors 138 6 to 170 10 (Standard programme) Amacan K 1300-520 with inlet nozzle (Part No. 138) 571 901.26 500.04 322
901.04
932.01 903.01 411.01 636.01 500.01 421.01 520.01 360 500.03
914.01 412.01 812 80-1
421.03 647
818
320 834.01 834.03
500.05 550.01 932.02 901.01 550.02 500.02
412.12 69-6 81-56
421.02
411.26
412.03 350
902.03 920.03 412.02
903.03 411.03 903.02 411.02 636.02
99-17 914.02 903.05 411.05 902.01 920.01
903.04 411.04 916.02 914.03 411.06
81-45 412.04
916.03
412.05 113 433.01 433.02
OW 380 105-00
940.03
550.23
260
931.01 230 901.21 412.06 502
101
412.20
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
Part No.
Part Designation
101 113 230 260 320 322 350 360 411 412
Pump casing Intermediate casing Impeller Impeller hub cap Anti--friction bearing Radial roller bearing Bearing housing Bearing cover Joint ring O-ring
421 433 500 502 520 550 571 636 647 69-6
Lip seal Mechanical seal Ring Casing wear ring Sleeve Disc Lug Grease nipple Grease regulator Temperature sensor
80-1 81-45 81-56 812 818 834 901 902 903 914
Semi-finished motor Float switch Moisture protection of motor Motor casing cover Rotor Cable duct Hexagon bolt Stud Screw plug Socket head cap screw
916 920 931 932 940 99-17
Plug Nut Lock washer Circlip Key Desiccant
17
Amacan K Mechanical seal detail
433.01
551.01
932.03 433.02
524 562.13 412.17
OW 309 124-00
figure 1 Seal variants for different pump types see table on p.10
Part No.
Part designation
Part No.
Part designation
433.01
Mechanical seal
551.01
Spacer sleeve
433.02
Mechanical seal
562.13
Parallel pin
412.17 524
O-ring Shaft protection sleeve
932.03
Circlip
18
Amacan K Mechanical seal detail
433.01 550.03 932.03 500.06 914.07 433.02 524 412.17 940.13 OW 309 110-00
figure 2
Seal variants for different pump types see table on p.10
Part No.
Part designation
Part No.
Part designation
433.01
Mechanical seal
433.02
Mechanical seal
550.03 914.07
Disc Socket head cap screw
412.17
O-ring
932.03
Circlip
500.06 524
Ring Shaft protection sleeve
940.13
Key
19
Amacan K Dimension tables for pump and support ring
OW 380 111-00
OW 380 085-00
d7 b20
20
Amacan K Pump and support ring all dim. in mm, standard programme up to 1200-540/10710 2, custom--made progr. from 1200-540/2606 upwards h1
h2
d1
d2
b
c
D
d7
b20
h20
f20
/ / / /
206 266 108 178
1195 1170 1195 1195
1000 975 1000 1000
670
556
250
130
711
570
691
60
5
/ / / /
206 266 108 178
1195 1170 1195 1195
1000 975 1000 1000
670
556
250
130
711
570
691
60
5
/ / / / /
206 266 286 376 456
1155 1130 1400 1400 1400
960 935 1080 1080 1080
640
250 250 369 369 369
130 130 232 232 232
813
656
793
60
2
/ / / / / / / / /
266 286 2 376 456 646 178 218 258 1 338 1
1225 1495 1495 1495 1600 1250 1225 1495 1495
930 1175 1175 1175 1280 1055 930 1175 1175
640
250 369 369 369 369 250 250 369 369
130 232 232 232 232 130 130 232 232
813
656
793
60
2
1575 1575 1680 1695 1695 1695 1575 1575 1680 1680
1255 1255 1360 1345 1345 1345 1255 1255 1360 1360
369 369 369 449 469 469 369 369 369 369
232 232 232 232 232 232 232 232 232 232
1016
856
992
70
8
1700 1900 1900 2150 2150 2150
1350 1550 1550 1770 1770 1770
449 469 469 577 577 577
232 232 232 382 382 382
70
8
2205 2205 1955 1955 2205 2205 2205 1765 1955 1955 1955 2205
1825 1825 1605 1605 1825 1825 1825 1415 1605 1605 1605 1825
577 577 469 469 577 577 577 449 469 469 469 577
382 382 232 232 382 382 382 232 232 232 232 382
70
2
2700
1935
--
--
1420
70
2
577
382
1320
622
494
1420
60
5
60
5
Amacan K . . . - . . . / . . .U/X . 700-330
700-324/321
800-370
800-380/381
1000-420/421
1000-500
(1300-500)
/ 376 / 456 / 646 / 806 / 1026 / 1206 / 258 / 338 / 438 / 548 / / / / / /
1 1 1 1
2 2 2
806 1 1026 1206 1386 1656 2006
(1300-540) (1300-540) 1200-540 1200-540 (1300-540) (1300-540) (1300-540) 1200-540 1200-540 1200-540 1200-540 (1300-540)
/ 1656 / 2006 / 848 / 1078 / 1268 / 1508 / 1808 / 4310 / 5410 / 6710 / 8410 /10710
(1400-540) (1400-540) 1300-520 1300-520 1300-520 (1400-520) 1300-520 1300-520 1300-520 1300-520
/ / / / / / / / / /
2606 3206 1268 1 1508 1 1808 1 2258 1 6710 1 8410 1 10710 1 12610 1
1300-750 (1400-750) (1400-750) (1400-750) (1400-750) (1400-750) (1400-750) (1400-750)
/ / / / / / / /
17010 2 21510 2 23510 2 27010 2 11012 13012 15512 18012
2 2 2 2 1 2 2 2 2
2600
760
770
970
970
1140
1140
840
820
960
960
2135
2900 2440
1970
2600
1250
1100
469
232
2135
577
382
2585
1920
577
2900
2135 622
2585
1920
2900
2135
1260
920
1016
992 856
1320
1292
1320
1292
1220
1192
1320
1015
1292
1220
1192
1320
1292 1015
1192 1292 1392
1155 1320
1292
382
1320
1292
494
1420
1170
1392
21
Amacan K Dimension table, discharge pipes Steel discharge pipes Overflow design B
Underfloor discharge C
OW 380 115-00
OW 380 113-00
Floor-mounted discharge D
Floor-mounted discharge D pressure--tight
OW 380 119-00
OW 380 117-00
b = to suit 22
b = to suit
Amacan K Main dimensions -- discharge pipes Pump sizes
all dimensions in mm
D
pipe dia.
A
DN2 min
DN2 max
H1 min
H3 min
700-330
711
700
650
300
600
1900
700-324/321
711
700
650
300
600
1900
800-370
813
800
700
400
700
2080
2850
800-380/381
813
800
700
400
700
2250
3020
1000-420/421
1016
1000
810
600
900
2520
3490
1000-500
1016
1000
810
600
900
2730
3700
1320
1300
960
1000
1300
3280
4660
1220
1200
910
900
1200
2930
4200
1320
1300
960
1000
1300
3280
1420
1400
1010
1100
1400
3640
1320
1300
960
1000
1300
1420
1400
1010
1100
1320
1300
960
1000
1200-540
1300-520 1300-750
Pump sizes
H1,H3 max
H2 min
H0 max
2570
670
7820
2570
670
7820
10000
770
7580
770
7410
(discharge pipes longer than 10,000 mm on request)
925
7040
925
6830
1130
6080
1080
6480
4660
1130
6080
5000
1180
5660
3110
4500
1130
6240
1400
3380
4800
1180
5920
1300
3420
4800
1130
5930
D
H4
M1
M2
M3
M4
N1
N2
N3
N4
700-330
711
500
800
1150
1160
1080
1160
910
455
695
700-324/321
711
500
800
1150
1160
1080
1160
910
455
695
800-370
813
550
900
1250
1260
1250
1260
1010
505
745
800-380/381
813
550
900
1250
1260
1250
1260
1010
505
745
1000-420/421
1016
650
1120
1460
1460
1450
1460
1210
605
855
1000-500
1016
650
1120
1460
1460
1450
1460
1210
605
855
1320
1000
1450
1760
1760
1700
1900
1510
755
1005
1220
930
1350
1670
1670
1600
1800
1410
710
960
1320
1000
1450
1760
1760
1700
1900
1510
755
1005
1420
1050
1550
1870
1870
1900
2040
1610
810
1060
1320
1000
1450
1760
1760
1700
1900
1510
755
1005
1420
1050
1550
1870
1870
1900
2040
1610
810
1060
1320
1000
1450
1760
1760
1700
1900
1510
755
1005
1200-540
1300-520 1300-750
Wall thickness against dia. D: -- up to size 800-380/381: 8 mm -- sizes 1000-420/421, 1000-500 with pipe diameter 1000 mm: 10 mm -- sizes 1000-500 with pipe diameter 1300 mm, 1200-540: 12 mm Discharge flanges to ISO 7005/2 / DIN 2501, PN 6 Admissible deviations for dimensions without tolerance indication: -- flange dimensions: ISO 2768 medium -- welding constructions: B/F to DIN EN ISO 13920
23
Amacan K Installation plan Installation example Installation mode BU
H geo
ha
hü
X
View
Y
t4
D
Minimum water level d7
A -- A 100
Section
350
t2
t3
t1
Y
s 1/2 min
e1
p2
s 1 min
Recommended inflow direction
Foundation holes
p2
=100
=p1
s 1 min
0-45°
View X (without pump)
A
Foundation holes
OW 380 120--00
A Subject to technical modifications
24
Support plate -- discharge pipes
Amacan K all dimensions in mm
Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750
D*)
t2
t3
t4 min
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
330 330 330 410 435 480 480 585 585 1025 1025 940
200 200 200 250 250 300 300 350 350 400 400 480
1900 1900 2080 2250 2520 2730 3280 2930 3280 3570 3670 3740
D*)
s1 min
p1
p2
ha
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700
900 900 1000 1000 1220 1220 1550 1450 1550 1550 1650 1550
640 640 740 740 960 960 1260 1160 1260 1260 1360 1260
100 100 100 100 100 100 100 100 100 100 100 100
Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750
t4 max
10000 ((discharge g pipes longer than 10,000 , mm on request)
d7
e1
570 570 656 656 856 856 856 1015 1015 1155 1155 1170
430 430 480 480 600 600 750 700 750 750 800 750
*) from size 1000-500 onwards, D depends on motor size, see page 21 hü [m]
Allowances for sump dimensions to DIN 18202, part 4, group B
Head loss diagram H = Hgeo + hü + v2/2g v as a function of DA
Overflow head ”hü” dependent on Q and the design of outlet diam. DA. The characteristic curves only apply for discharge unobstructed on all sides; otherwise to be regarded as an approximation.
Q [m3/s]
OW 380 110--00
Overflow head hü
Amacan K 1300-750
Diagram for minimum water level t1
700-- 324/321
25
Amacan K Installation plan Installation example Installation mode CU
X
DN2 can be chosen with regard to the desired outlet speed. See table DN2min/DN2max and head loss diagram.
A
DN 2
t5
A
a
t4
H geo
Vent pipe
D
View
Y
Minimum water level d7
t2
t3
t1
Y
Section
e1
A -- A
s 1/2 min
250
300
200
s 1 min
View X (without discharge pipe cover, without pump)
Recommended inflow direction
Foundation holes
p1
a3 p2
0-45°
s 1 min
Foundation holes
a1
OW 380 121-00
Subject to technical modifications 26
200
a2
200
Support plate -- discharge pipe
Amacan K all dimensions in mm
Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750
D*)
t2
t3
t4 min
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
330 330 330 410 435 480 480 585 585 1025 1025 940
200 200 200 250 250 300 300 350 350 400 400 480
2570 2570 2850 3020 3490 3700 4660 4200 4660 5350 5550 5520
Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750
t4 max
10000 (discharge pipes longer than 10,000 mm on request) q )
d7
e1
s1 min
570 570 656 656 856 856 856 1015 1015 1155 1155 1170
430 430 480 480 600 600 750 700 750 750 800 750
1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700
D*)
p1
p2
DN2 min
DN2 max
a
a1
a2
a3
t5 min
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
860 860 960 960 1160 1160 1600 1500 1600 1600 1740 1600
960 960 1060 1060 1260 1260 1700 1600 1700 1700 1840 1700
300 300 400 400 600 600 1000 900 1000 1000 1100 1000
600 600 700 700 900 900 1300 1200 1300 1300 1400 1300
650 650 700 700 810 810 960 910 960 960 1010 960
1100 1100 1200 1200 1410 1410 1710 1620 1710 1710 1820 1710
850 850 950 950 1160 1160 1460 1370 1460 1460 1570 1460
430 430 480 480 580 580 730 685 730 730 785 730
670 670 770 770 925 925 1130 1080 1130 1130 1180 1130
*) from size 1000-500 onwards, D depends on motor size, see page 21 HV ges [m]
Allowances for sump dimensions to DIN 18202, part 4, group B
Head loss diagram H = Hgeo + HV ges HV ges includes: -----
elbow disch. pipe length = 5xDN2 check valve outlet loss v2/2g
OW 380 110--00
Q [m3/s]
Diagram for minimum water level t1
Amacan K 1300-750
700-- 324/321
27
Amacan K Installation plan Installation example Installation mode DU
DN2 can be chosen with regard to the desired outlet speed. See table DN2min/DN2max and head loss diagram.
X
DN 2
H4
-- not pressure sealed
t6
a
t7
A A
View
Y
t4
D
Vent pipe d7
Minimum water level
t2
t3
t1
Y Section
A -- A
s 1/2 min
250
300
p1
e1
p2
0-45°
200 OW 380 122-00
Subject to technical modifications 28
View X (without pump)
Foundation holes
s 1 min
Recommended inflow direction
s 1 min
200
Foundation holes
a1
a2
Support plate -- discharge pipe 200
Amacan K all dimensions in mm
Main dimensions of discharge pipe and pump sump Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750 Pump sizes 700-330 700-324/321 800-370 800-380/381 1000-420/421 1000-500 1200-540 1300-520 1300-750
D*)
t2
t3
t4 min
t4 max
d7
e1
s1 min
p1
p2
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
330 330 330 410 435 480 480 585 585 1025 1025 940
200 200 200 250 250 300 300 350 350 400 400 480
1250 1250 1430 1600 1765 1975 2180 1860 2180 2740 2840 2910
8680 8680 8580 8580 8275 8275 7520 7660 7520 7520 7420 7520
570 570 656 656 856 856 856 1015 1015 1155 1155 1170
430 430 480 480 600 600 750 700 750 750 800 750
1000 1150 1150 1400 1600 1800 1800 2250 2250 2250 2250 2700
860 860 960 960 1160 1160 1460 1360 1460 1460 1560 1460
960 960 1060 1060 1260 1260 1560 1460 1560 1560 1660 1560
D*)
DN2 min
DN2 max
a
a1
a2
t6 min
t6 max
H4
711 711 813 813 1016 1016 1320 1220 1320 1320 1420 1320
300 300 400 400 600 600 1000 900 1000 1000 1100 1000
600 600 700 700 900 900 1300 1200 1300 1300 1400 1300
650 650 700 700 810 810 960 910 960 960 1010 960
860 860 960 960 1160 1160 1460 1360 1460 1460 1560 1460
610 610 710 710 910 910 1210 1110 1210 1210 1310 1210
820 820 870 870 1075 1075 1480 1410 1480 1460 1530 1480
8250 8250 8020 7850 7585 7375 6820 7210 6820 6260 6110 6090
500 500 550 550 650 650 1000 930 1000 1000 1050 1000
t7 max
10000 ((discharge g pipes longer than 10,000 , mm on request)
*) from size 1000-500 onwards, D depends on motor size, see page 21 hV Kr [m]
Allowances for sump dimensions to DIN 18202, part 4, group B
Head loss diagram H= Hgeo + hV Kr + HV Anl Except for hV Kr all losses must be calculated with a view to plant conditions
OW 380 110--00
Q [m3/s]
Diagram for minimum water level t1
Amacan K 1300--750
700-- 324/321
29
Amacan K Pump with suspension wire and tensioning device in discharge pipe turnbuckle
Part list
59-8
59-17.2
Part No.
Part designation
Material
59-8 59-17.2 59-47 59-24
Turnbuckle Shackle Carrier cable Carrier cable to DIN 3088, form PK Spacer
1.4571 1.4571 1.4751
720
1.4401 EPDM
59-47
59-24 Cross-section of carrier cable arrangement (Where free cable length in discharge pipe exceeds 3.5 m, this arrangement is absolutely necessary)
Plastic hose for clamp
Carrier cable
59-24
Clamp
59-17.2
OW 380 091-00
Control cable
Spacer
Power supply cable
Cable length in discharge pipe exceeding 3.5 m: Mounting of tensioning device 59-8 -- closed discharge pipe: on the discharge pipe cover (see ill. above) -- open discharge pipe of installation mode BU on a girder above water level, to be supplied on site
OW 380 090-00
30
Cable length in discharge pipe under 3.5 m: On open discharge pipe: electrical cables must be mounted on a girder above water level (to be supplied on site) to avoid damages by the swirl of the water.
Amacan K Discharge pipe cover with cable duct Design variant: with welding sleeve Top view
Section
A -- A 3
A A
OW 380 836-00
1 2 3 4 5
2
5
4
1
5
Discharge pipe cover Cover Welding sleeve with input bushing acc. to DIN 22 419 with strain relief, protection against buckling and torsion Bracket for fixing turnbuckle (cable) Gasket, rubber reinforced with fabric
Note: Versions with split cover are possible, too.
31
Amacan K Discharge pipe cover with cable duct Design variant: with cable gland
Top view
View
X
X
2
A
3
A
Section
A -- A
OW 380 861-00
1 1 2 3 4 5 6 7 8
6
8
4
7
Discharge pipe cover Cable gland, type RGP (cable gland) Tecron modules (packing and filling) Cover segment with cable duct Sealing of the cover division with closed cell profile gasket, which may be pre-stressed by inserting an O-ring. Division guard Holding brackets for cover segment with cable glands Gasket, rubber reinforced with fabric
Note: Versions with split cover are possible, too.
32
5
Amacan K Selection table -- Example The following steps lead to a correct selection of pump:
Amacan K 800-381
980 1/min Laufradform Impeller type Forme de roue
Given data:
Capacity Q=400 l/s Head H=6m Liquid temp. t=30 °C Non-flameproof Material type G
A
145 x 135 mm Nr.
:
4 : 3 2 : 1 :
Q [ l/s ] H [m]
freier Durchgang free passage section de passage
D2A / D2I [mm] 408 / 378 398 / 344 384 / 317 367 / 295
H [m]
Impeller diameter
H [ft]
Förderhöhe Head Hauteur
With available QH data, the impeller diam. D2A is approx. 400 mm and thus Pduty can be found.
B
Pduty P [kW]
P2 min
The maximum value of the characteristic curve P through Pduty is the minimum motor power P2 min
C
Minimum motor power P2 min
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-381/...
Nr.
U or X
P2
(Flameproof)
kW
U tmax = 30
°C -
X tmax = 40
Motor size
°C
Irated
Istarting 1)
cos
j
d.o.l. A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia
mm2
mm
Weight Control cable 2) kg
24
.../266 U
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
730
28
.../286 U
60.0
250
0.78
2x4x4
16.6-18.7
A
780
37
.../376 U
77.0
335
0.78
2x4x6
17.8-19.8
A
870
45
.../456 U
92.0
460
0.79
2x4x10
21.7-23.7
A
930
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
730
28
.../376 X
61.0
335
0.75
2x4x4
16.6-18.7
A
870
37
.../456 X
77.0
460
0.77
2x4x6
17.8-19.8
A
930
45
.../646 X
106.0
600
0.69
2x4x10
21.7-23.7
A
1030
Motor size is to be selected by considering temperature and flameproof/ non-flameproof designs. Selected: Motor version ”U”, (non--flameproof), motor with 37.0 kW, 6--pole Designation of complete pump set: : Amacan K 800--381 / 376 U G For further data refer to the tables on pages 34-55 and motor documentation Amarex KRT Rh.-Nr. 2553.53/. . .-90 For a flameproof machine or tmax = 40 °C, motor .../45 6 X G should be used. Note : Impellers are trimmed to the operating point. The QH data should be clearly stated at the time of ordering, in order to define the exact impeller diameter.
33
Amacan K Amacan K 700-321
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 323 / 323 3 : 320 / 305 2 : 314 / 280 1 : 305 / 251
H [m]
105 x 115
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-321/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
A
Power supply cable Cross-section
Outside dia.
mm2
mm
Weight Control cable kg
U
18
.../206 U
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 30 °C
24
.../266 U
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
X
18
.../206 X
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 40 °C
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
34
Amacan K Amacan K 700-321
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 323 / 323 3 : 320 / 305 2 : 314 / 280 1 : 305 / 251
H [m]
105 x 115
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-321/...
Nr.
U or X
P2
(Flameproof)
kW
U
10
tmax = 30 °C X tmax = 40 °C
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
Power supply cable Cross-section
Outside dia.
Weight Control cable
mm2
mm
0.79
1x(12x2.5)
22.7--24.7
--
410
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
65
0.79
1x(12x2.5)
22.7--24.7
--
410
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
A
A
.../108 U
22.5
65
16
.../178 U
36.0
10
.../108 X
22.5
16
.../178 X
36.0
kg
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
35
Amacan K Amacan K 700-324
980 1/min Laufradform Impeller type Forme de roue
70 x 70
mm freier Durchgang free passage section de passage
Nr. : D2A / D2I [mm] 3 : 324 / 324 2 : 309 / 280 1 : 290 / 234
H [m] Förderhöhe Head Hauteur
H [ft]
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Förderstrom/Rate of Flow/Débit
Courbes selon ISO 9906/A.
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-324/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
A
Power supply cable Cross-section
Outside dia.
mm2
mm
Weight Control cable kg
U
18
.../206 U
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 30 °C
24
.../266 U
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
X
18
.../206 X
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 40 °C
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
36
Amacan K Amacan K 700-324
735 1/min Laufradform Impeller type Forme de roue
70 x 70 Nr. : D2A / D2I [mm] 3 : 324 / 324 2 : 309 / 280 1 : 290 / 234
H [m] Förderhöhe Head Hauteur
H [ft]
P [kW]
mm
freier Durchgang free passage section de passage
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-324/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
Power supply cable Cross-section
Outside dia.
mm2
mm
A
Weight Control cable kg
U
10
.../108 U
22.5
65
0.79
1x(12x2.5)
22.7-24.7
--
410
tmax = 30 °C
16
.../178 U
36.0
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
X
10
.../108 X
22.5
65
0.79
1x(12x2.5)
22.7-24.7
--
410
tmax = 40 °C
16
.../178 X
36.0
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on requestt
37
Amacan K Amacan K 700-330
980 1/min Laufradform Impeller type Forme de roue
70 x 92
Nr. : D2A / D2I [mm] 4 : 326 / 326 3 : 300 / 292 2 : 287 / 245 1 : 270 / 214
H [m] Förderhöhe Head Hauteur
H [ft]
P [kW]
mm
freier Durchgang free passage section de passage
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Förderstrom/Rate of Flow/Débit
Courbes selon ISO 9906/A.
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-330/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
A
Power supply cable Cross-section
Outside dia.
mm2
mm
Weight Control cable kg
U
18
.../206 U
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 30 °C
24
.../266 U
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
X
18
.../206 X
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
430
tmax = 40 °C
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
470
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
38
Amacan K Amacan K 700-330
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 326 / 326 3 : 310 / 310 2 : 295 / 266 1 : 278 / 231
H [m]
70 x 92
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.
Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
700-330/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
Power supply cable Cross-section
Outside dia.
mm2
mm
A
Weight Control cable kg
U
10
.../108 U
22.5
65
0.79
1x(12x2.5)
22.7-24.7
--
410
tmax = 30 °C
16
.../178 U
36.0
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
X
10
.../108 X
22.5
65
0.79
1x(12x2.5)
22.7-24.7
--
410
tmax = 40 °C
16
.../178 X
36.0
115
0.79
1x(7x4+5x1.5)
26.9--28.8
--
435
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
39
Amacan K Amacan K 800-370
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 370 / 370 3 340 / 340 2 : 318 / 303 1 : 300 / 278
H [m] Förderhöhe Head Hauteur
75
H [ft]
P [kW]
mm
freier Durchgang free passage section de passage
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.
Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-370/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight Control
cable 2) kg
18
.../206 U
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
505
U
24
.../266 U
48,.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
565
tmax = 30 °C
28
.../286 U
60.0
250
0.78
2x4x4
16.6--18.7
A
710
37
.../376 U
77.0
335
0.78
2x4x6
17.8--19.8
A
780
18
.../206 X
35.5
160
0.85
1x(7x4+5x1.5)
26.9--28.8
--
505
X
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
565
tmax = 40 °C
28
.../376 X
61.0
335
0.75
2x4x4
16.6--18.7
A
780
37
.../456 X
77.0
460
0.77
2x4x6
17.8--19.8
A
860
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm
40
Amacan K Amacan K 800-380
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 388 / 363 3 376 / 341 2 : 355 / 306 1 : 332 / 268
115 x 95
mm
freier Durchgang free passage section de passage
H [m]
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-380/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
A
Power supply cable Cross-section
Outside dia.
mm2
mm
Weight
Control cable 2) kg
28
.../286 U
60.0
250
0.78
2x4x4
16.6--18.7
A
780
U
37
.../376 U
77.0
335
0.78
2x4x6
17.8--19.8
A
870
tmax = 30 °C
45
.../456 U
92.0
460
0.79
2x4x10
21.7--23.7
A
930
64
.../646 U
139.0
600
0.75
2x4x16
27.1--30.1
A
1030
28
.../376 X
61.0
335
0.75
2x4x4
16.6--18.7
A
870
37
.../456 X
77.0
460
0.77
2x4x6
17.8--19.8
A
930
45
.../646 X
106.0
600
0.69
2x4x10
21.7--23.7
A
1030
X tmax = 40 °C
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ;
41
Amacan K Amacan K 800-380
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 388 / 363 3 376 / 341 2 : 355 / 306 1 : 332 / 268
115 x 95
H [m]
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-380/...
Nr.
U or X
P2
(Flameproof)
kW
U tmax = 30 °C X tmax = 40 °C
Irated
Istarting 1)
j
d.o.l.
Electric cables NSSHöu-J Power supply cable Cross-section
mm
0.79
1x(7x4+5x1.5)
26.9--28.8
150
0.75
1x(7x10+5x1.5)
230
0.73
2x4x4
36.0
115
0.79
.../218 X
44.0
150
.../338 X1
60.0
300
A
.../178 U
36.0
115
20
.../218 U
44.0
25
.../258 U1
57.0
16
.../178 X
20 25
Weight Control
cable 2) kg --
630
29.5--32.9
--
700
16.9-18.7
A
870
1x(7x4+5x1.5)
26.9--28.8
--
630
0.75
1x(7x10+5x1.5)
29.5--32.9
--
700
0.69
2x4x4
16.6-18.7
A
930
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2)Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
42
Outside dia.
mm2
A
16
cos
Amacan K Amacan K 800-381
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 408 / 378 3 398 / 344 2 : 384 / 317 1 : 367 / 295
145 x 135
H [m]
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-381/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight Control
cable 2) kg
24
.../266 U
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
730
U
28
.../286 U
60.0
250
0.78
2x4x4
16.6-18.7
A
780
tmax = 30 °C
37
.../376 U
77.0
335
0.78
2x4x6
17.8-19.8
A
870
45
.../456 U
92.0
460
0.79
2x4x10
21.7-23.7
A
930
24
.../266 X
48.5
225
0.84
1x(7x10+5x1.5)
29.5--32.9
--
730
X
28
.../376 X
61.0
335
0.75
2x4x4
16.6-18.7
A
870
tmax = 40 °C
37
.../456 X
77.0
460
0.77
2x4x6
17.8-19.8
A
930
45
.../646 X
106.0
600
0.69
2x4x10
21.7-23.7
A
1030
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
43
Amacan K Amacan K 800-381
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 408 / 378 3 : 398 / 344 2 : 384 / 317 1 : 367 / 295
145 x 135
H [m]
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
800-381/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
Electric cables NSSHöu-J
d.o.l.
A
Power supply cable Cross-section
Outside dia.
mm2
mm
A
Weight Control cable kg
U
16
.../178 U
36.0
115
0.79
1x(7x4+5x1.5)
26.9-28.8
--
630
tmax = 30 °C
20
.../218 U
44.0
150
0.75
1x(7x10+5x1.5)
29.5-32.9
--
700
X
16
.../178 X
36.0
115
0.79
1x(7x4+5x1.5)
26.9-28.8
--
630
tmax = 40 °C
20
.../218 X
44.0
150
0.75
1x(7x10+5x1.5)
29.5-32.9
--
700
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request
44
Amacan K Amacan K 1000-420
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 6 : 450 / 420 5 430 / 400 4 : 420 / 370 3 : 403 / 349 2 : 387 / 322 1 : 370 / 302
H [m]
126 x 100
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1000-420/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
Electric cables NSSHöu-J Power supply cable Cross-section
A
A
Outside dia.
mm2
mm
Weight
Control cable 2) kg
45
.../456 U1
92.0
460
0.79
2x4x10
21.7--23.7
A
1050
U
64
.../646 U1
139.0
600
0.74
2x4x16
27.1--30.1
A
1200
tmax = 30 °C
80
.../806 U1
158.0
740
0.81
2x4x25
32.8--35.8
A
1400
102
.../1026 U
200.0
1140
0.82
2x4x25
32.8--35.8
A
1550
45
.../646 X1
105.0
600
0.69
2x4x10
21.7--23.7
A
1200
X
64
.../806 X1
131.0
740
0.77
2x4x16
27.1--30.1
A
1400
tmax = 40 °C
80
.../1026 X
158.0
1140
0.80
2x4x25
32.8--35.8
A
1550
102
.../1206 X
200.0
1450
0.79
2x4x25
32.8--35.8
A
1650
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
45
Amacan K Amacan K 1000-420
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 6 : 450 / 420 5 430 / 400 4 : 420 / 370 3 : 403 / 349 2 : 387 / 322 1 : 370 / 302
H [m]
126 x 100
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.
Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1000-420/...
Nr.
U or X
P2
(Flameproof)
kW
U tmax = 30 °C X tmax = 40 °C
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Control cable 2) kg
25
.../258 U2
57.0
230
0.73
2x4x4
16.6--18.7
A
1000
33
.../338 U2
72.0
300
0.75
2x4x6
17.8--19.8
A
1050
43
.../438 U
100.0
460
0.70
2x4x10
21.7--23.7
A
1150
25
.../338 X2
59.0
300
0.70
2x4x4
16.6--18.7
A
1050
33
.../438 X
85.0
460
0.64
2x4x10
21.7--23.7
A
1150
43
.../548 X
105.0
560
0.66
2x4x10
21.7--23.7
A
1200
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm
46
Weight
Amacan K Amacan K 1000-421
980 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 450 / 415 3 434 / 386 2 : 416 / 356 1 : 396 / 324
H [m]
140 x 150
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1000-421/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight
Control cable 2) kg
37
.../376 U1
77.0
335
0.78
2x4x6
17.8--19.8
A
1010
U
45
.../456 U1
92.0
460
0.79
2x4x10
21.7--23.7
A
1050
tmax = 30 °C
64
.../646 U1
139.0
600
0.74
2x4x16
27.1--30.1
A
1200
80
.../806 U1
158.0
740
0.81
2x4x25
32.8--35.8
A
1400
37
.../456 X1
77.0
460
0.77
2x4x6
17.8--19.8
A
1050
45
.../646 X1
105.0
600
0.69
2x4x10
21.7--23.7
A
1200
64
.../806 X1
131.0
740
0.77
2x4x16
27.1--30.1
A
1400
X tmax = 40 °C
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm
47
Amacan K Amacan K 1000-421
735 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 450 / 415 3 434 / 386 2 : 416 / 356 1 : 396 / 324
140 x 150
H [m]
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1000-421/...
Nr.
U or X
P2
(Flameproof)
kW
U tmax = 30 °C
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight
Control cable 2) kg
25
.../258 U2
57.0
230
0.73
2x4x4
16.6--18.7
A
1000
33
.../338 U2
72.0
300
0.75
2x4x6
17.8--19.8
A
1050
43
.../438 U
100.0
460
0.70
2x4x10
21.7--23.7
A
1150
19
.../258 X2
46.0
230
0.68
2x4x4
16.6--18.7
A
1000
X
25
.../338 X2
59.0
300
0.70
2x4x4
16.6--18.7
A
1050
tmax = 40 °C
33
.../438 X
85.0
460
0.64
2x4x10
21.7--23.7
A
1150
43
.../548 X
105.0
560
0.66
2x4x10
21.7--23.7
A
1200
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm
48
Amacan K Amacan K 1000-500
980 1/min
(applies to Amacan K 1300-500, too)
Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 4 : 508 / 508 3 460 / 460 2 : 448 / 412 1 : 430 / 350
H [m]
145 x 110
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A.
Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1000-500/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
Electric cables NSSHöu-J Power supply cable Cross-section
A
A
Outside dia.
mm2
mm
Weight
Control cable 2) kg
80
.../806 U1
158.0
740
0.81
2x4x25
32.8--35.8
A
1470
102
.../1026 U
200.0
1140
0.82
2x4x25
32.8--35.8
A
1630
U
120
.../1206 U
230.0
1450
0.82
2x4x35
36.9--39.9
A
1750
tmax = 30 °C
138
.../1386 U
245.0
1750
0.87
2x4x35
36.9--39.9
B
2050
165
.../1656 U
285.0
1670
0.89
2x4x50
42.9--45.9
B
2200
200
.../2006 U
345.0
2400
0.91
2x3x70/35
48.4--51.4
B
2350
80
.../1026 X
158.0
1140
0.80
2x4x25
32.8--35.8
A
1630
102
.../1206 X
200.0
1450
0.80
2x4x25
32.8--35.8
A
1750
120
.../1386 X
215.0
1750
0.87
2x4x35
36.9--39.9
B
2050
138
.../1656 X
240.0
1670
0.89
2x4x35
36.9--39.9
B
2200
165
.../2006 X
258.0
2400
0.90
2x4x50
42.9--45.9
B
2350
X tmax = 40 °C
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
49
Amacan K Amacan K 1200-540
980 1/min
(applies to Amacan k 1300-540 and 1400-540, too)
Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380
H [m]
133 x 150
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1200-540/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight
Control cable 2) kg
165
.../1656 U
285.0
1670
0.89
2x4x50
42.9--45.9
B
3000
U
200
.../2006 U
345.0
2400
0.91
2x3x70/35
48.4--51.4
B
3150
tmax = 30 °C
260
.../2606 U
450.0
1920
0.89
2x3x95/50
55.0--59.0
B
3550
320
.../3206 U
590.0
3700
0.83
4x4x50
42.9--45.9
B
3750
165
.../2006 X
285.0
2400
0.90
2x4x50
42.9--45.9
B
3150
200
.../2606 X
345.0
1920
0.88
2x3x70/35
48.4--51.4
B
3550
260
.../3206 X
470.0
3700
0.84
4x4x35
36.9--39.9
B
3750
X tmax = 40 °C
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
50
Amacan K Amacan K 1200-540
735 1/min
(applies to Amacan K 1300-540, too)
Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380
H [m] Förderhöhe Head Hauteur
133 x 150
mm
freier Durchgang free passage section de passage
H [ft]
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Irated
Istarting 1)
Motor
Motor
Amacan K
Code
design
rating
1200-540/...
Nr.
U or X
P2
(Flameproof)
kW 84
.../848 U
177.0
680
U
107
.../1078 U2
225.0
1000
tmax = 30 °C
126
.../1268 U2
240.0
150
.../1508 U2
285.0
84
.../1078 X2
X
107
tmax = 40 °C
126 150
cos
j
d.o.l.
Electric cables NSSHöu-J Power supply cable
Weight
Control cable 2)
Cross-section
Outside dia.
mm2
mm
0.77
2x4x25
32.8--35.8
A
2400
0.76
2x4x35
36.9--39.9
A
2500
1220
0.83
2x4x35
36.9--39.9
B
2910
1400
0.82
2x4x50
42.9--45.9
B
3100
199.0
1000
0.67
2x4x25
32.8--35.8
A
2500
.../1268 X2
205
1220
0.82
2x4x35
36.9--39.9
B
2910
.../1508 X2
250.0
1400
0.80
2x4x50
42.9--45.9
B
3100
.../1808 X2
275.0
1700
0.85
2x4x50
42.9--45.9
B
3210
A
A
kg
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable : A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
51
Amacan K Amacan K 1200-540
590 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 5 : 582 / 550 4 : 565 / 517 3 : 550 / 474 2 : 540 / 442 1 : 520 / 380
H [m]
133 x 150
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1200-540/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Weight
Control cable 2) kg
43
.../4310 U1
99.0
380
0.68
2x4x10
21.7--23.7
A
2250
U
54
.../5410 U2
121.0
420
0.71
2x4x16
27.1--30.1
A
2350
tmax = 30 °C
67
.../6710 U2
149.0
540
0.71
2x4x16
27.1--30.1
A
2450
84
.../8410 U2
189.0
680
0.70
2x4x25
32.8--35.8
A
2550
43
.../5410 X2
102.0
420
0.67
2x4x10
21.7--23.7
A
2350
X
54
.../6710 X2
125.0
540
0.68
2x4x16
27.1--30.1
A
2450
tmax = 40 °C
67
.../8410 X2
159.0
680
0.66
2x4x25
32.8--35.8
A
2550
84
.../10710 X2
185.0
980
0.70
2x4x25
32.8--35.8
B
2900
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside : 16.5--18.7 mm ; B = 1x10x1.5 ; Outside : 18.7--20.7 mm
52
Amacan K Amacan K 1300-520
735 1/min
(applies to Amacan K 1400-520, too)
Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 5 : 612 / 532 4 : 600 / 505 3 : 585 / 487 2 : 570 / 460 1 : 560 / 435
H [m]
145
mm
freier Durchgang free passage section de passage
H [ft]
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs. Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1300-520/...
Nr.
U or X
P2
(Flameproof)
kW
Irated
Istarting 1)
cos
j
d.o.l.
Electric cables NSSHöu-J Power supply cable Cross-section
A
A
Outside dia.
Weight
Control cable 2)
mm2
mm
2x4x35
36.9--39.9
B
3050
kg
126
.../1268 U1
235
1220
0.84
U
150
.../1508 U1
290
1400
0.82
2x4x50
42.9--45.9
B
3200
tmax = 30 °C
180
.../1808 U1
335
1700
0.84
2x3x70/35
48.4--51.4
B
3350
225
.../2258 U1
425
2650
0.83
2x3x95/50
55.0--59.0
B
3900
126
.../1508 X1
245
1400
0.81
2x4x35
36.9--39.9
B
3200
X
150
.../1808 X1
275
1700
0.85
2x4x50
42.9--45.9
B
3350
tmax = 40 °C
180
.../2258 X1
355
2650
0.80
2x3x70/35
48.4--51.4
B
3900
225
.../2808 X1
445
3420
0.78
2x3x95/50
55.0--59.0
B
4250
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
53
Amacan K Amacan K 1300-520
590 1/min Laufradform Impeller type Forme de roue
Nr. : D2A / D2I [mm] 5 : 612 / 532 4 : 600 / 505 3 : 585 / 487 2 : 570 / 460 1 : 560 / 435
H [m]
145
H [ft]
mm
freier Durchgang free passage section de passage
Förderhöhe Head Hauteur
P [kW]
P [hp]
Leistungsbedarf Power Input Puiss. hyd. abs.
Kennlinien nach ISO 9906/A Curves as per ISO 9906/A. Courbes selon ISO 9906/A. Förderstrom/Rate of Flow/Débit
400 V 50 Hz 3~ (winding 400/690 V) max. temperature of liquid handled 30/40°C Motor
Motor
Amacan K
Code
design
rating
1300-520/...
Nr.
U or X
P2
(Flameproof)
kW
U tmax = 30 °C X tmax = 40 °C
Irated
Istarting 1)
cos
j
d.o.l.
A
A
Electric cables NSSHöu-J Power supply cable Cross-section
Outside dia.
mm2
mm
Control cable 2) kg
67
.../6710 U1
149
540
0.71
2x4x16
27.1--30.1
A
2650
84
.../8410 U1
189
680
0.70
2x4x25
32.8--35.8
A
2750
107
.../10710 U1
220
980
0.75
2x4x35
36.9--39.9
B
3000
67
.../8410 X2
159
680
0.66
2x4x25
32.8--35.8
A
2750
84
.../10710 X2
185
980
0.70
2x4x25
36.9--39.9
B
3000
107
.../12610 X2
205
1070
0.82
2x4x35
36.9--39.9
B
3200
Data applies to a density of 1 kg/dm3 and a kinematic viscosity of up to max. 20 mm2/s Warranty acc. to ISO 9906/A 1) further starting modes on request 2) Control cable: A = 1x8x1.5 ; Outside: 16.5--18.7 mm ; B = 1x10x1.5 ; Outside: 18.7--20.7 mm
54
Weight
Amacan K Hydraulic data of pump sizes
-- 1300--750 on request
55
Amacan K Order detail -- carrier cable length In order to select the proper length of the carrier cable, it is absolutely necessary to define dimension ”L”.
mm
-
lower edge of pit = lower edge of pump
KSB Aktiengesellschaft P.O. Box 200743 · 06008 Halle (Saale) · Turmstraße 92 · 06110 Halle (Germany) Tel. +49 (345) 48 26 0 · Fax +49 (345) 48 26 46 99 · www.ksb.com
1579.5/3--10
10/97
L=
Subject to modification without notice
suspension at the cover or with BU / BG / A at a support
L
-