PROGRAM OF ACCEPTANCE CRITERIA FOR LABORATORY TESTS OF REINFORCEMENT BARS UNIT CALCULATED MINIMUM NOMINAL MEASURED WEIGHT(kg/m) UNIT TOLERANCE BAR DIA BAR DIA (mm) AS PER IS WEIGHT(kg/m) (kg/m) (mm)
MAXIMUM TOLERANCE (kg/m)
REMARK
4
0.099
0.000
0.098
0.099
NOT ACCEPTABLE
5
0.154
0.000
0.153
0.155
NOT ACCEPTABLE
6
0.222
0.000
0.221
0.223
NOT ACCEPTABLE
7
0.302
0.000
0.301
0.304
NOT ACCEPTABLE
8
0.395
0.000
0.393
0.397
NOT ACCEPTABLE
10
0.617
0.000
0.614
0.620
NOT ACCEPTABLE
12
0.888
0.000
0.884
0.893
NOT ACCEPTABLE
16
1.579
0.000
1.571
1.587
NOT ACCEPTABLE
18
1.998
0.000
1.988
2.008
NOT ACCEPTABLE
20
2.467
2.340
2.455
2.479
NOT ACCEPTABLE
25
3.855
0.000
3.836
3.874
NOT ACCEPTABLE
28
4.836
0.000
4.811
4.860
NOT ACCEPTABLE
32
6.316
0.000
6.284
6.347
NOT ACCEPTABLE
36
7.994
0.000
7.954
8.034
NOT ACCEPTABLE
19.5
40
9.869
0.000
9.819
9.918
NOT ACCEPTABLE