PROGRAM OF ACCEPTANCE CRITERIA FOR LABORATORY TESTS OF REINFORCEMENT BARS Fe 415 WITH REFERNCE TO DIAMETER OF INDIVIDUAL SAMPLE UNIT CALCULATED MINIMUM MAXIMUN NOMINAL MEASURED WEIGHT(kg/m) UNIT TOLERANCE TOLERANCE BAR DIA BAR DIA (mm) AS PER IS WEIGHT(kg/m) (mm) (mm) (mm) 4 5 6 7 8 10 12 16 18 20 25 28 32 36 40
0.099 0.154 0.222 0.302 0.395 0.617 0.888 1.579 1.998 2.467 3.855 4.836 6.316 7.994 9.869
8.126 9.96 11.984 15.66 19.97 25.198 27.32 31.180 34.43
0.000 0.000 0.000 0.000 0.406 0.611 0.884 1.509 0.000 2.455 3.907 4.592 5.983 7.295 0.000
3.980 4.975 5.970 6.965 7.960 9.950 11.940 15.920 17.910 19.900 24.875 27.860 31.840 35.820 39.800
4.020 5.025 6.030 7.035 8.040 10.050 12.060 16.080 18.090 20.100 25.125 28.140 32.160 36.180 40.200
REMARK
NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
PROGRAM OF ACCEPTANCE CRITERIA FOR REINFORCEMENT BARS Fe 415
UNIT UNIT WEIGHT NOMINAL WEIGHT(kg/m) AS PER LAB BAR DIA AS PER IS TESTS(kg/m) (mm) 4 5 6 7 8 10 12 16 18 20 25 28 32 36 40
0.099 0.154 0.222 0.302 0.395 0.617 0.888 1.579 1.998 2.467 3.855 4.836 6.316 7.994 9.869
0.000 0.000 0.000 0.000 0.406 0.611 0.884 1.509 0.000 2.455 3.907 4.592 5.983 7.295 0.000
Acceptability of size (measurement of diameter taken at lab) NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
MINIMUM MAXIMUN UNIT WEIGHT TOLERANCE TOLERANCE Acceptabilty of Unit Weight MENTIONED IN (kg/m) as per (kg/m)as per as per TC T.C.(kg/m) IS 1786 and IS 1786 and SP 34 SP 34 0.092 0.143 0.206 0.281 0.367 0.574 0.844 1.500 1.938 2.393 3.739 4.691 6.126 7.754 9.573
0.106 0.165 0.238 0.323 0.422 0.660 0.933 1.658 2.058 2.541 3.971 4.981 6.505 8.233 10.165
NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
e 415
Acceptabilty of Unit Weight as per Lab calulations NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
PROGRAM OF ACCEPTANCE CRITERIA FOR LABORATORY TESTS OF REINFORCEMENT BARS - Fe500 WITH REFERNCE TO DIAMETER OF INDIVIDUAL SAMPLE UNIT CALCULATED MINIMUM MAXIMUN NOMINAL MEASURED WEIGHT(kg/m) UNIT TOLERANCE TOLERANCE BAR DIA BAR DIA (mm) AS PER IS WEIGHT(kg/m) (mm) (mm) (mm) 6 8 10 12 16 18 20 25 28 32 36 40
0.222 0.395 0.617 0.888 1.579 1.998 2.467 3.855 4.836 6.316 7.994 9.869
0.000 0.000 0.000 15.94 0.000 0.000 24.340 0.000 31.894 34.59
0.000 0.000 0.000 0.000 1.563 0.000 0.000 3.646 0.000 6.260 7.362 0.000
5.970 7.960 9.950 11.940 15.920 17.910 19.900 24.875 27.860 31.840 35.820 39.800
6.030 8.040 10.050 12.060 16.080 18.090 20.100 25.125 28.140 32.160 36.180 40.200
REMARK
NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
PROGRAM OF ACCEPTANCE CRITERIA FOR REINFORCEMENT BARS Fe500
UNIT UNIT WEIGHT NOMINAL WEIGHT(kg/m) AS PER LAB BAR DIA AS PER IS TESTS(kg/m) (mm) 6 8 10 12 16 20 25 28 32 36 40
0.222 0.395 0.617 0.888 1.579 2.467 3.855 4.836 6.316 7.994 9.869
0.000 0.000 0.000 0.000 1.563 0.000 3.646 0.000 6.260 7.362 0.000
Acceptability of size (measurement of diameter taken at lab) NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
MINIMUM MAXIMUN UNIT WEIGHT TOLERANCE TOLERANCE Acceptabilty of Unit Weight MENTIONED IN (kg/m) as per (kg/m)as per as per TC T.C.(kg/m) IS 1786 and IS 1786 and SP 34 SP 34 0.206 0.367 0.574 0.844 1.500 2.393 3.739 4.691 6.126 7.754 9.573
0.238 0.422 0.660 0.933 1.658 2.541 3.971 4.981 6.505 8.233 10.165
NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE
Fe500
Acceptabilty of Unit Weight as per Lab calulations NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE ACCEPTABLE NOT ACCEPTABLE NOT ACCEPTABLE