prepared by :Maruti Saptale QCA Executive bulk drug industry
. CALIBRATION RECORD OF DIGITAL BALANCE MODEL: - SHIMADZU BL 220 H [Sr. No.: 0455003216 ]
DATE
STANDARD WEIGHT 0.010 gm 0.020 gm 0.050 gm 0.100 gm 0.500 gm 1.000 gm 5.000 gms 10.000 gms 50.000gms 100.000 gms 150.000 gms 200.000 gms 0.010 gm 0.020 gm 0.050 gm 0.100 gm 0.500 gm 1.000 gm 5.000 gms 10.000 gms 50.000gms 100.000 gms 150.000 gms 200.000 gms 0.010 gm 0.020 gm 0.050 gm 0.100 gm 0.500 gm 1.000 gm 5.000 gms 10.000 gms 50.000gms 100.000 gms 150.000 gms 200.000 gms 0.010 gm 0.020 gm 0.050 gm 0.100 gm 0.500 gm 1.000 gm 5.000 gms 10.000 gms 50.000gms 100.000 gms 150.000 gms 200.000 gms
LIMIT: -NMT-0.1% FREQUENCY: - Daily
BALANCE WEIGHTS
INSTRUMENT No.: - QC/004
CALIBRATED BY
REMARK
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF DIGITAL BALANCE MODEL: - SHIMADZU AUX 220 [Sr. No.: D449513426]
DATE
STANDARD WEIGHT 0.0100 gm 0.0200 gm 0.0500 gm 0.1000 gm 0.5000 gm 1.0000 gm 5.0000 gms 10.0000 gms 20.0000gms 50.0000 gms 100.0000 gms 0.0100 gm 0.0200 gm 0.0500 gm 0.1000 gm 0.5000 gm 1.0000 gm 5.0000 gms 10.0000 gms 20.0000gms 50.0000 gms 100.0000 gms 0.0100 gm 0.0200 gm 0.0500 gm 0.1000 gm 0.5000 gm 1.0000 gm 5.0000 gms 10.0000 gms 20.0000gms 50.0000 gms 100.0000 gms 0.0100 gm 0.0200 gm 0.0500 gm 0.1000 gm 0.5000 gm 1.0000 gm 5.0000 gms 10.0000 gms 20.0000gms 50.0000 gms 100.0000 gms
LIMIT: -NMT-0.1% FREQUENCY: - Daily
BALANCE WEIGHTS
INSTRUMENT No.; - QC/005
CALIBRATED BY
REMARK
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF DIGITAL pH METER Model: - PHAN (Sr. No.PN08210549)
SR.NO.
DATE
BUFFER SOLUTIONS pH-4.0 pH -7.0 pH -9.2
INSTRUMENT No. - QC/007
CALIBRATED BY
REMARK
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LIMIT: - pH MUST NOT DIFFER BY MORE THAN 0.05
FREQUENCY: - DAILY
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF DIGITAL MELTING POINT Model: VMP-DS ( Sr. No.: 10/0508 ) INSTRUMENT No.:- QC/008 MELTING POINT OF STANNDARD REFERANCE SUBSTANCE SR.NO. CALIBRATED REMARK DATE VANILLIN ACETANILIDE CAFFEIN BY 810C- 830 C 114 OC -116O C 234 O C -237 O C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 FREQUENCE: - ONCE IN THREE MONTHS
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF POLARIMETER Model :-RSP-1 SR. .No.
DATE
CONCENTRACTIN GMS/100ML
1
2
3
4
5
6
7
8
9 FREQUENCE :-ONCE in Three month
STANDARD ANGLE OF ROTATION AT 25 0C
Instrument No. :- QC/005 OBSERVED ANGLE OF CHECKED REMARK ROTATION BY AT 25 0C
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF DIGITAL VACUUM OVEN Model :- JRIC-5 [ Oswal vacuum oven ]
S R.N O.
DATE
SET TEMPERATURE
1
2
3
4
5
6
7
8 Frequency :- Once in year
Instrument No. : QC/012
OBSERED TEMPERATURE
CHECKED BY
REMARK
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF DIGITAL BALANCE Model :-GR –200 [ AND ] Sr. No.
DATE
STANDARD WEIGHT
INSTRUMENT No. - QC/009 BALANCE WEIGHTS
CHECKED BY
1
2
3
4
5
6
LIMIT: -NMT-0.1%(THREE WEIGHTS NMT-0.001)
FREQUENCY ;-MONTHLY
REMARK
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF HUMIDITY CHAMBER Model :-CH-06S
Sr. No.
Date
1 2
3
4
5
6
7
8
9
10
Frequency :- Yearly
Instrument No. :- QC/011
Adjusted Temperature
Observed Temperature
Checked By
Remark
prepared by :Maruti Saptale QCA Executive bulk drug industry
CALIBRATION RECORD OF ULTRASONIC BATH Model :-UCB-50
Sr. No.
Instrument No. :- QC/015
TEST
Date
Checked By Solubility
1
2
3
4
5
6
7
8
9
10
Frequency :- Yearly
Timer
Heater
Remark