Inspection note of BE(central yard) station conducted by ADSTE/BE on date 25.07.17 1.0
ASM Office 1.1 All magneto &CNL phone tested found in working order. 1.2 All sealing button at panel found in seal condition. 1.3 VHF set tested found in working order. 1.4 Panel counter reading found as under-
EUUYZ 05470 05470
On panel In Record 1.5
EUYZ 05470 05470
EUUYZ 01494 01494
COZ 1105 1105
Signal failure register-
Month
S&T
Engg
OI
Other
RE
Total
NF
O/S
Apr17
8
15
4
0
0
27
0
04
May17 Jun17
6 7
5 5
2 3
1 2
2 0
16 17
1 1
1 4
1.6
SI-4 record
Month Apr 17 May 17 Jun 17 1.7
Accepted 21 29 29
Not Accepted 08 02 07
Relay room opening
Month Apr 17 May 17 June 17
Opening of R/room 15 9 14
Relay room opening is on the higher side in April and June. 2.0
Out door signaling gearsPoint no.119B,120A,122,123A&134B tested with 5mm obstruction test and found responded correctly, electrical parameter and other observation are as underPt no.
119 B 120 A
Norm al operation N-R R-N
Normal operation Voltag curre e nt 115V 2.8A 2.3A
With obstruction voltag curre e nt 106V 4.8A 5.01A
Track locking
N-R
116V
108V
Effectiv e
1.81A
4.63A
Effectiv e
122
123 A
134 B
R-N
117V
1.9A
109V
4.39A
N-R
119V
2.16A
113V
4.62A
R-N
117V
2.3A
104V
5.01A
N-R
117V
1.85A
115V
1.96A
R-N
116V
1.89A
114V
2.3A
N-R
108V
1.8A
86V
3.95A
R-N
114V
1.52A
101V
4.38A
Pt 119B- No lubricant and sand inside point machine Pt 120A- LH side switch rail knife edge and chipped off. Pt 122- Friction clutch to be washed with K-oil Pt 134B- Painting of ground connection to be done. 3.0
Location Box no. L 18 checked and found following parameter-
T.Ckt no 134ATR 134BTR 133ATR 133BTR External voltage at Bus bar
Voltage at relay 3.86V 3.43V 3.58V 3.5V 27.5V
Location Box no. L 25C checked and found following parameter
T.Ckt no 04ATR 05ATR 119ATR 119BTR External voltage at Bus bar Track feed AC Voltage at S27 RG 4.0
Voltage at relay Train on line 3.59V 2.81V 2.4V 28.27V 109V 107V
IPS Room:- Checked and found OK. Capacity 300AH, DOI 25/06/2015, Make- Exide
Effectiv e Effectiv e Effectiv e Effectiv e Effectiv e Effectiv e Effectiv e
Cell No
1
5
10
14
17
21
Voltage(V)
2.04
2.06
2.06
2.05
2.06
2.05
Gravity
1230
1230
1230
1230
1230
1230
Cell No
26
31
36
40
44
48
Voltage(V)
2.05
2.06
2.06
2.05
2.06
2.06
Gravity
1230
1230
1230
1230
1240
1230
Cell No
52
55
Voltage(V)
2.05
2.05
Gravity
1230
1240
ADSTE/BE Copy to: Sr. DSTE1/MB for kind information ADEN/SPN for information and necessary action