Hydraulic Pump Selection Guide

  • June 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Hydraulic Pump Selection Guide as PDF for free.

More details

  • Words: 20,162
  • Pages: 38
AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 1

2007 Hydraulic Pump Selection Guide

w w w . h y p r o p u m p s . c o m

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 2

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 3

Table of Contents

Description Page Cutaway View of 9303C-HM4C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Tips for Better Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 Selecting the Right Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-7 Agco Tractor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Agco Allis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Allis Chalmers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Belarus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10 Case/David Brown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 J.I. Case . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11 Case IH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-13 Caterpillar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Challenger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-14 Deutz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15 Deutz Allis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Fendt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Ford & Ford New Holland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-19 Hesston-Fiat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20 International Harvester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21 John Deere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-24 Kubota . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Massey-Ferguson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25-28 McCormick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Minneapolis Moline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Oliver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Steiger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-31 Valtra . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Versatile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31-32 White . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 4

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 1

Hydraulic Pump Selection Guide Hypro offers a wide variety of hydraulic-driven centrifugal pumps for use in agricultural tractor applications. This guide will help you to select the appropriate pump for your situation. Simply locate your tractor manufacturer and model number, hydraulic system type, pressure and flow rate. The guide will show you which Hypro pump is best for you.

Outlet Port

Mechanical Seal

Shaft Seal

Main Bearings

Ball Bearing

Gerotor

Tank Port Adapter

Stainless Steel Wear Ring Pressure Port Adapter

Inlet Port

O-ring Seal

Motor End Plate Shaft Gerotor Housing O-ring Seal

Drain/Vent Plug

Motor Body

Pump Casing Mounting Flange

Cutaway view of Model 9303C-HM4C centrifugal pump

1

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 2

Tips for Better Performance Best Practices for Tractor Hydraulics There are many tractors with a variety of hydraulic capabilities. How you get the most use of your tractor’s power depends on your skill as a good operator and manager. Here are some tips to follow that will lead you to greater pump performance, and in the long run, will add to your success.

Rule #1 Minimize hydraulic motor back pressure in the return line hydraulic hose. High hydraulic motor back pressure can rob performance from your Hypro pump. As you can see in the chart below, for the same spray pressure, there is a 40 gallon per minute loss in performance due to excessively high hydraulic back pressure in the return line of the spray pump’s hydraulic hose. Those 40 gallons could be used to spray at faster ground speed, increase flow to agitation, or to reduce the required hydraulic flow necessary to do the job. Whatever your need is, reducing hydraulic back pressure saves you money!

2

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:36 AM

Page 3

By reducing your motor’s hydraulic back pressure, the amount of available energy to the hydraulic motor increases and that energy can be used for work. Here are some of the most common sources of high hydraulic motor back pressure. 1. Tractor Return Valve Block A free dump return port is the best way to minimize return back pressure. This free dump return, bypasses the tractor valve block spool and greatly reduces hydraulic back pressure. Free dump return ports help to reduce the back pressure, but can vary for tractor models. A realistic back pressure goal is 50 – 150 PSI. 2. Quick Coupler Size Modern tractors provide a free dump option and because this option is designed to reduce back pressure for constant operating hydraulic equipment, they usually increase the coupler size. By increasing its size, a larger cross-sectional area is provided for the hydraulic oil to flow through the coupler without greatly increasing the back pressure. 3. Return Hose Diameter For hydraulic flows greater than 13 GPM, the standard 1 ” /2 hose can be limiting in its capacity to carry higher hydraulic flows back to the tractor reservoir. Factors that create higher back pressures of a hose include hose diameter and hose length. If the pump is not located near the hitch, consider upsizing the hydraulic hose size to reduce motor hydraulic back pressure. 4. Tractor Hydraulic Filter Condition Older tractors may feel the effect of neglect with their age. If you intend to get the most out of your tractor, check your maintenance records to be sure the hydraulic filter has been recently changed. The higher the hydraulic flow, the higher the pressure drop is across any restriction. This includes the filter. It is not uncommon to see a 200 PSI pressure drop across a dirty filter. 5. Secondary Circuits Secondary circuits can be used for the spray pump hydraulic pressure supply, but free dump returns should always be used with them. Standard tractor secondary return ports are even more restrictive than primary return ports.

3

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:37 AM

Page 4

The best way to know your hydraulic oil back pressure is to measure it. Hypro provides a Hydraulic Test Kit (PN: 3430-0650) that can easily be inserted into the hydraulic circuit of the Hypro spray pump. You can instantly learn what your hydraulic back pressure is as well as the tractor’s system pressure and hydraulic flow. This is a great diagnostic tool for those who need to improve their performance. Ask for this test kit at your sprayer dealer.

Rule #2 Know Where to Set the Bypass Screw This Hypro hydraulic motor feature is intended solely for Open Center hydraulic systems. Follow directions for bypass screw adjustments in the owner manual. If your hydraulic system is a Closed Center pressure compensating or load sensing system, be sure bypass screw is turned in completely.

Rule #3 On/Off Operation Whenever possible use the rate controller for On/Off control of your spray nozzles. Cycling the pump on and off does provide more opportunity to damage the hydraulic motor’s oil seal, especially if the hydraulic return line is through the circuit spool valve. In the graph below, you can see that over 3000 PSI pressure is trapped in the motor until it slowly seeps down to zero PSI. That pressure is exerted directly against the hydraulic oil lip seal in the motor. Trapping high hydraulic oil pressure in the motor will lead to early seal failures. Using a free dump will avoid hydraulic oil from having to go through the circuit spool valve and will alleviate the possibility of trapped pressure in the motor as well as lower the back pressure in the motor to increase its performance.

4

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:37 AM

Page 5

Selecting the Right Pump Hypro offers several sizes as well as materials for its line of hydraulic motor-driven centrifugal pumps. Inlet port sizes from 11⁄2" to 2" are available. Material options include Polypropylene, Cast Iron, and 316 Stainless Steel. Up to five different motor sizes are available for each combination of port size and construction material. The following is a listing of the nominal flow ranges for each motor size:

Motor GM1 HM2C HM4C HM1C HM5C HM3C

1

2

3

4

5

6

7

8

Hydraulic Flow Range (GPM) 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

The chart above has been used to create the selection guide contained in this document. Hydraulic system types, age of equipment, and levels of performance were also taken into consideration. IMPORTANT: The tractor hydraulic system data contained in the following tables should be used only as a guide. Consult your tractor manufacturer for more detailed information or for assurance that any continuous duty equipment, such as hydraulic motor-driven centrifugal pumps, will not overheat your hydraulic system. Hydraulic Pumps: Today’s tractors are equipped with either Constant Displacement or Variable Displacement Hydraulic Pumps. Constant Displacement Pumps put out a constant flow, regardless of pressure (until the relief valve bypasses the flow). The only way to vary the flow on this type of pump is to change engine speed. Variable Displacement Pumps will produce only the flow required by the implement until total pump output is reached. If less than total pump output is required, an automatic stroke control mechanism decreases the pump output to maintain a constant pressure and flow. The output varies according to demand. Hydraulic Controls: There are two types of hydraulic control or spool valves used on tractors today. They are named after the design of the spool valves themselves. One is called OPEN CENTER because in the neutral (or center) position, it is open to allow flow back to the hydraulic reservoir. Open Center Valves are used exclusively on Constant Displacement Pumps. The other valve type is called a CLOSED CENTER because in the neutral (or center) position, all hydraulic flow is stopped on that circuit. Closed Center Valves are used exclusively on Variable Displacement Pumps. There are four basic positions for each type of spool valve. They are Raise, Neutral, Lower and Float (in order, from back to front). The names used for these positions vary somewhat between manufacturers, but the order of the positions do not. To properly operate a hydraulic motor-driven centrifugal pump on a tractor hydraulic circuit, only the Lower and Float positions should be used. Use Lower for “On” and Float for “Off.” The Float position is recommended for turning the motor off because it allows the remote circuit to flow in a continuous loop, allowing the motor to free wheel to a stop and also does not trap pressure in the circuit. Both Open and Closed Center Valves trap oil on both sides of the remote circuit when in the Neutral position. Use of this position for “Off” will cause premature failure of the hydraulic motor for two reasons. One is that using Neutral to stop the motor will do so in a fraction of a second. With both lines of the circuit closed, the motor will be forced to stop instantly from as much as 6000 RPM. This can cause damage to the motor shaft, oil seal and gerotor. The other type of failure mode caused by using the Neutral position is oil seal failure. The Neutral position of the spool valve can trap in excess of 1000 PSI in the remote circuit. While Hypro’s oil seals are designed to withstand some of these pressure spikes, they are not designed to withstand them indefinitely.

5

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:37 AM

Page 6

Selecting the Right Pump (continued) The Raise position is not recommended for “On” because the valve must travel through the Neutral position to get to Float. System Types: There are three types of hydraulic systems used on tractors. One utilizes a constant displacement pump and is called an Open Center System because of the spool valve employed. The other two use a variable displacement pump and are known as Closed Center (Pressure Compensated) Systems or Closed Center Load Sensing Systems based on the type of spool valve and system operation. Open Center systems, while having constant displacement pumps, do change flow rates with engine RPM. It is, therefore, necessary to make adjustment to the hydraulic-driven pump with tractor engine speed as close as possible to what it will be operating at in the field. Hydraulic flow on many Open Center systems decreases when power steering is in use or when other hydraulic circuits are in use (i.e. when raising or lowering booms); consequently so does centrifugal pump flow. Typically the largest motor possible is recommended for these types of systems. Closed Center (Pressure Compensating) systems have a variable displacement pump which will deliver flow at the necessary rate to maintain a specified pressure. It is desirable to equip implements with a motor of a low flow range that will cause the pump to operate between 1800 and 2100 PSI. Selecting a motor that is too large to operate in this pressure range may cause the generation of excess heat in the hydraulic oil, causing damage to the tractor’s transmission parts. Closed Center Load Sensing systems are similar to pressure compensated systems, but are designed primarily for more efficient operation and the generation of less heat. They work on the principle of maintaining a constant pressure drop from the pump to the work port of the selector valve. Any variation in demand at the motor will cause a change in flow. The system senses this change in flow due to the change in pressure drop across the valve and causes the pump to compensate by varying the pump flow. Hydraulic Plumbing: Many tractor hydraulic systems route return lines through filters or other restrictive elements which can cause an increase in return circuit pressure. Hypro’s hydraulic motor oil seals are designed to withstand 300 PSI continuous operation and up to 600 PSI intermittently. This is well within the range of nearly every tractor’s return circuit pressure. However, whenever possible, it is recommended to utilize either a standard (or purchase an optional) low pressure return circuit. This will allow for less oil heat generation, lower horsepower consumption and longer oil seal life. Consult with your tractor manufacturer to see if your tractor is or can be equipped in this way. The Return (or Tank) ports on Hypro hydraulic motors are equipped with an anti-reversing check valve. This is to prevent the motor from accidentally being operated backwards. Backward operation of the motor will cause almost immediate oil seal failure. Do Not Remove Check Valve. HM2 and HM4 models of Hypro’s hydraulic motor-driven centrifugal pumps can be equipped with a metering orifice in the inlet port. The orifice is intended to be used on older model tractors with Closed Center systems that do not have flow control valves. Consult with your tractor manufacturer to determine if you have this type of system and require an orifice. Further information is available with your pump’s operating manual. Hypro hydraulic motors are equipped with a bypass adjustment screw. These are only to be adjusted when used on Open Center hydraulic systems. Please see the installation instructions included with the pump for directions on how to use the bypass. Closed Center hydraulic systems do not require any bypass. Be sure that the bypass adjustment is screwed all the way in and the lock nut is tight when operating on Closed Center systems.

6

AG_270_Hydraulic_Guide_1206.qxp

12/22/06

9:37 AM

Page 7

Installation Basics: Open Center Systems 1. Do not use an orifice in the pressure adapter port. 2. Start the tractor. Leave the selector valve in neutral and achieve operation RPM and system temperature. 3. Open the bypass screw 4 turns. 4. With the pump inlet flooded, move the selector valve to the Lower position and allow hydraulic flow to the motor. 5. Adjust the bypass screw closed until the desired spraying pressure is achieved. Account for agitation flow. 6. Tighten the lock nut on the bypass screw. Closed Center System-Pressure Compensating* 1. Install the #1 orifice in the pressure adapter port (HM2 and HM4 only). 2. Start the tractor. Leave the selector valve in neutral and achieve operating RPM and system temperature. 3. Close and lock the bypass screw. 4. With the pump inlet flooded, move the selector valve to the Lower position and allow hydraulic flow to the motor. 5. If spraying pressure is too low, replace the #1 orifice with the #2 orifice. Account for agitation flow. 6. If spraying pressure is still too low, replace the #2 orifice with the #3 orifice. 7. If spraying pressure is still too low, remove the orifice completely. * Some closed center systems are equipped with flow controls (Tortoise/Hare), such as John Deere. Metering orifices are unnecessary in these systems. Follow the operation instructions for closed center load sensing systems. Closed Center Load Sensing 1. Do not use an orifice in the pressure adapter port. 2. Start the tractor. Leave the selector valve in neutral and achieve operating RPM and system temperature. 3. Adjust the tractor’s hydraulic flow control (Tortoise/Hare) to its lowest setting. 4. Close and lock the bypass screw. 5. With the pump inlet flooded, move the selector valve to the Lower position and allow hydraulic flow to the motor. 6. Adjust the hydraulic flow control valve (Tortoise/Hare), until the desired spraying pressure is achieved. Account for agitation flow. IMPORTANT! All hydraulic connectors on motor hoses and tractors must be clean. Any foreign particles can severely damage the motor and your hydraulic system. Know your hydraulic system! Hypro hydraulic motors will operate at a maximum of 2000 PSI continuously and 2200 PSI intermittently. Exceeding these pressures may seriously damage the motor. When shutting off the pump, move the selector to the “FLOAT” position to allow the centrifugal pump to come to a stop gradually.

Make sure pump inlet is flooded prior to allowing hydraulic flow to the motor.

The following specifications are published by the tractor manufacturers. Actual hydraulic conditions at the auxillary ports are expected to vary.

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

7

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

9:37 AM

Maximum Pressure (PSI)

Hydraulic System Type

Page 8

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

AGCO TRACTOR DT160 DT180 DT200 DT220 DT225 DT240 GT45 GT55 GT65 GT75 LT70 LT75 LT85 LT90 RT95 RT100CVT RT115 RT120CVT RT130 RT135CVT RT145

CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS)

2900 2900 2900 2900 2900 2900 2750 2750 2750 2750 3045 3050 3045 3050 2900 2900 2900 2900 2900 2900 2900

29/39 29/39 29/39 39 29/39 39 12.6 12.6 12.6 12.6 18 23/15 18 23/15 28 29 28 29 29/39 29 29/39

1 1 1 1 1 1 2 2 2 2 /3 /3 1 1 1 1 1 1 1

2 2 2 2 2 2 3 3 3 3 2 2/ 2 2/

/3 /3 2 2 2 2 2 2 2

1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1

1 /2 1 /2 1 1 1 1 1 1 1

2 2/ 2 2/ 2 2 2 2 2 2 2

1 /2 1 /2 1 1 1 1 1 1 1

2 2 2 1 1

2 2 2 3 1 3 3 3

2 2 2 2 2

AGCO ALLIS 4650 OPEN (a) 2610 8.8 2610 10.3 4660 OPEN (a) 5650 OPEN (a) 2750 11 OPEN (a) 2750 11 5660 2610 15.2 5670 OPEN (a) OPEN (a) 2610 14.5 5680 6670 OPEN (a) 2610 15.2 6680 OPEN (a) 2610 17.1 6690 OPEN (a) 2610 17.1 7600 OPEN (a) 2610 24.7 7630 OPEN (a) 2610 25.7 7650 OPEN (a) 2610 24.7 8360 CLOSED (LS) 2500 27 2500 27 8425 CLOSED (LS) 2610 25 OPEN (a) 8610 8630 OPEN (a) 2610 25 8745 OPEN 3045 25.8 8765 OPEN 3045 25.8 CLOSED (LS) 2900 27.7 8775 8785 CLOSED (LS) 2900 27.7 9435 CLOSED (LS) 2900 27 2900 27 CLOSED (LS) 9455 9630 CLOSED 2250 24 9635 CLOSED 2250 22 9650 CLOSED 2250 24 9655 CLOSED 2250 22 CLOSED 2500 23 9670 2500 22 CLOSED 9675 9690 CLOSED 2500 23 9695 CLOSED 2500 22 9735 CLOSED (LS) 2900 29/39 9745 CLOSED (LS) 2900 29/39 9755 CLOSED (LS) 2900 29/39 9765 CLOSED (LS) 2900 29/39 9775 CLOSED (LS) 2900 29/39 2900 29/39 CLOSED (LS) 9785 22 2750 CLOSED 9815 (a) Optional auxiliary hydraulic reservoir is recommended to prevent overheating.

2 2 2 2 3 1 3 3 3

2 3 3 3 3 3 2 2 2 2 2

1 1

2 2

8

1 1

2 2

2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CODE KEY (1) (2) (3) (LS)

2 2 2

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

1 1 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

ALLIS CHALMERS 160 170-G 170-D 175 CROP HUSTLER 175-G 175-D 180-G 180-D 185 185 AFTER 1972 185-D 190-D 190-GXT 190-DXT 200-D 210 210 AFTER 1972 220 220 AFTER 1972 440 5015 5020 5030 5040 5040 AFTER 1978 5045 5050 5050 AFTER 1978 6040 6060 6070 6080 6140 7000 7010-PD 7010-PS 7020 7020-PS 7030 7040 7040-PS 7045 7045-PS 7050 7060 7060-PS 7080 7580 8010 8030 8050 8070 8550 4W220 4W305 4W306

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

BELARUS 400 & 420 505 & 525 530 & 532 570 & 572 615 800, 802, 805 820, 822, 825, 825R

OPEN OPEN OPEN OPEN OPEN OPEN OPEN

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Page 9

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2300 2000 2000 2000 2400 2400 2000 2000 2000 2000 2400 2000 2000 2000 2400 2000 2400 2000 2400 2000 1990 1900 1900 2133 2133 2770 2133 2133 2300 2300 2300 2300 2000 2400 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500

6.7 10 10 11 11 11 10 10 10 11 11 12.75 12.75 12.75 13.2 18 18 18 18 20 5.4 5.4 5.4 5.75 6.23 6.25 6.23 6.47 7 10 10 10 10 5.88 17 17 17 17 17 17 17 17 17 17 17 17 18 18 17 17 17 17 18 23 21 23

3

2 3 3 3 3 3 3 3 3 3 3 3 3 3 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3 3 3 3 3 3 3 3 2 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2050 2800 2525 2800 2550 2525 2525

11.8 11.8 11.8 11.8 11.8 11.8 11.8

2 2 2 2 2 2 2

3 3 3 3 3 3 3

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 1

2 2 2 2 2

1

2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

9

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

BELARUS (continued) 900,902,905 920,922,925 1025 5011, 5011L 5045, 5045L 5111, 5145 6011, 6045 6311, 6345 1770 7010 7100 7100M 8011, 8011L, 8021 8311, 8345 9011, 9011L, 9021, 9045 9311, 9345

12/22/06

Hydraulic System Type

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

9:37 AM

Maximum Pressure (PSI)

2525 2525 2525 2525 2525 2525 2525 2525 2610 2000 2000 2000 2525 2525 2525 2525

Page 10

Maximum Flow (GPM)

HM1C

11.8 11.8 11.9 11.9 11.9 10.9 11.8 11.8 28.2 17.8 20 28 12.2 12.2 11.8 11.8

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2 2 2 2 2 2 2

3 3 3 3 3 3 3 3 2 2 2 2

1

2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2

1 1 3 3 3 3

2 1

2 2 2 2

CASE/DAVID BROWN 780 OPEN 2000 7.3 3 2 OPEN 2000 7.3 3 2 880 885 OPEN 2500 (a) 7.3 3 2 OPEN 2500 (a) 7.3 3 2 990 995 OPEN 2500 (a) 7.3 3 2 OPEN 2000 6.9 (b) 3 2 1200 1210 OPEN 2500 (a) 6.9 (b) 3 2 1212 OPEN 2500 (a) 6.9 (b) 3 2 3 2 2500 7.3 (b) 1410 OPEN 1410 AFTER 1977 OPEN 2500 15.5 3 2 3 2 OPEN 2500 7.3 (b) 3 2 1412 3800 OPEN 2000 7.3 3 2 4600 OPEN 2000 7.3 3 2 (a) All 1972 model tractors and earlier have a maximum pressure of 2000 PSI. (b) Maximum flow capacity is 15.5 GPM on some models equipped with larger hydraulic pump. On these models, the HM5C motor is recommended for both the 9303C and 9304C pumps. J. I. CASE 470 570 770 870 970 1070 1090 1170 1175 1190 1194 1270 1270 AFTER 1973 1290 1294 1370 1370 AFTER 1973 1390 1394 1410 1470 1490 1494 1570 1594 1690 1896 2090 2094

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED (LS) CLOSED (LS) CLOSED (LS)

1550 1550 1550 1550 1900 2100 2250 2250 2250 2200 2200 2200 2050 2200 2200 2200 2050 2200 2200 2500 2000 2200 2200 2200 2200 2200 2250 2250 2250

8.6 9.3 14-16 14-16 14-16 14-16 14-16 14-16 14-16 7.25 7.25 20 20 7.25 7.25 20 20 15.3 15.3 15.5 16 15.3 15.3 20 20.1 20.1 22 22 23

3

2 2 3 3 3 3 3 3 3 2 2

3 3 3 3 3 3 3 3 3 3

10

3 3 3 3 3 3 3

2 2 3 3

2 2 2 2 2 2 2

2 2 2 2

2 2 3 3 3 3 3 3

2 2 3 3 3 3 3 3

2 2 2 2 2 2

3 3 3 3 3 3

2 2 2 1 1 1

CODE KEY (1) (2) (3) (LS)

2 2 2 2 2 2 2

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 2 2 2 2 2 2 2

2 2 2

2 2 2

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

J. I. CASE cont. 2096 2290 2294 2390 2394 2470 2590 2590 AFTER 1979 2594 2670 2870 3294 3394 3594 4490 4494 4690 4694 4890 4894 4994

CLOSED CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

CASE IH 235 245 255 265 275 350B 385 395 450B 450C 485 495 585 595 685 695 850C 850D 885 895 995 1120 1130 1140 1394 1494 1594 1896 2096 2130 2140 2150 2294 2394 2594 3220 3230 4210 4230 4240 4494 4694

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED OPEN OPEN OPEN CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS)

(LS) (LS) (LS)

(LS) (LS)

9:37 AM

Page 11

Maximum Pressure (PSI)

Maximum Flow (GPM)

2250 2250 2250 2250 2250 2050 2250 2250 2250 2050 2050 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250

22 22 22 24 24 17 24 23 24 17 22 23 17 17 24 24 24 24 24 24 30

1920 1994 1994 2175 2175 1650 2500 2500 NA NA 2500 2500 2500 2500 2500 2500 NA NA NA 2500 2500 2175 2175 2175 2300 2300 2300 2250 2250 2650 2650 2650 2250 2250 2250 2500 2500 2500 2500 2500 2250 2250

3.4 4.6/5.9 4.8/6.1 5.7 7.3 14 11.3 11.3(a)/13.4(b) 21 22 11.3 12.6(a)/13.4(b) 12.6 12.1(a)/14.3(b) 12.7(a)/15.1(b) 15.8(a)/18.1(b) 21 31 12.7(a)/15.7(b) 12.8(a)/15.1(b) 15.8(a)/18.1(b) 5.4 7.2 7.2 15.3 15.3 20.1 23 23 6.8(a)/10.5(b) 6.8(a)/10.5(b) 6.8(a)/10.5(b) 23 25 25 14.7-16.9 15.3-17.7 16.1-18.4 16.1-18.4 16.1-18.4 24 24

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

1 1 1 1 1

2 2 2 2 2 3

1 1 1

2 2 2 2

3 2 1 1 1 1 1 1 1 1 1 1

1 2 2

2 2 2 2 (a) 2 (a)

2 (a) 2 (a)

3 3 1 1 2 (b) 2 (b) 2 (b) 1 1 1 3(a) 3(a)

1 1

2 2 2 2 2 3

2

2 2 2 2

2 2

2 2 2 2 2 2 2 2 2 2

NOTHING RECOMMENDED RECOMMENDED NOTHING 2 2 2 3 2 3 2 3 3 2 2 3 3 3 3 2 (b) 3 2 (b) 2(b) 3(a) 2(a)1(b) 2 2 3 2 (b) 3 2 (b) 2(b) 3(a) 2(a)1(b) 2 3 2 3 2 3 2 3 2 2 2 2 3(a) 2(a)3(b) 3(a) 2(a)3(b) 3(a) 2(a)3(b) 2 2 2 2 3(a) 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2

1 2 2

2

2 2 2 2 2 2 (a) 2 (a) 2(b) 2 2 2 (a) 2 (a) 2(b)

3 3

2 (b) 2 (b) 2(a)1(b)

2 (b) 2 (b) 2(a)1(b)

2 2 2

2 2 2 (b) 2 (b) 2 (b) 2 2 2 3(a) 3(a)

2 2 2 2 2

2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

11

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

CASE IH cont. 4894 4994 5120 5130 5140 5220 5230 5240 5250 7110 7120 7130 7140 7150 7210 7220 7230 7240 7250 8910 8920 8930 8940 8950 9110 PUMA 9130 WILDCAT 9150 COUGAR 9170 9180 9210 9230 9240 9250 9260 9270 9280 9310 9330 9350 9370 9380 9390 C50,CX50 C60,CX60 C70,CX70 C80,CX80 C90,CX90 C100,CX100 CVX1135 CVX1145 CVX1155 CVX1170 CVX1190 QUADTRAC MX80,MX80C MX90,MX90C MX100,MX100C MX110 MX120 MX135 MX150 MX170 MX180 MX200 MX210 MX220

12/22/06

Hydraulic System Type

CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Page 12

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

2250 2650 2750 2750 2750 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2300 2800 2800 2800 2800 2800 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2900 2900 2900 2900 2900 2900 2500 2500 2500 2500 2500 2500 2750 2750 2750 2750 2750 2900 2950 2950 2950 2950 2950 2950 2950 2950 2900 2900 2930 2900

24 28 17 17 17 20.1 20.1 20.1 20.1 29 29 29 29 29 22 22 22 22 22 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 28 28 30 30 30 30/60 13 16 16 16 16 16 28 28 28 34.3 34.3 30 25 25 25 25 25 25 28 28 30/44 30/44 38.6/53.1 30/44

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 3 3 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

CODE KEY

12

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

CASE IH cont. MX230 MX240 MX255 MX270 MX285 MXM120 MXM130 MXM140 MXM150 MXM155 MXM175 MXM190 MXU100 MXU110 MXU125 MXU135 (a) Standard Hydraulic System (b) Optional Hydraulic System

12/22/06

Hydraulic System Type

CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Page 13

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

2930 2900 2930 2900 2930 2750 2750 2750 2750 2750 2750 2750 3045 3045 3045 3045

38.6/53.1 30/44 38.6/53.1 30/44 38.6/53.1 28 28 28 28 28 31.7 31.7 19.8/26.5 19.8/26.5 19.8/26.5 19.8/26.5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CATERPILLAR CLOSED (LS) 2500 35 45 CLOSED (LS) 2500 CLOSED (LS) 2750/2900 55 65B CLOSED (LS) 2500 CLOSED (LS) 2550 65C CLOSED (LS) 2750/2900 65D 65E CLOSED (LS) 2900 CLOSED (LS) 2550 70B-70C 2550 75B CLOSED (LS) 75C CLOSED (LS) 2550 75D CLOSED (LS) 2750 75E CLOSED (LS) 2900 85C CLOSED (LS) 2550 85D CLOSED (LS) 2550 85E CLOSED (LS) 2900 95E CLOSED (LS) 2900 (a) Hydraulic oil coolers are not standard on these models. An oil cooler

24 1 2 24 1 2 24/31.2 1 2 26 (a) 1 2 27/35 1 2 27.5 1 2 30 1 2 35 1 2 1 2 35 (a) 27/35 1 2 27.5 1 2 30 1 2 27/35 1 2 35 1 2 30 1 2 30 1 2 is required for continous duty sprayer pump operation.

CHALLENGER MT445 MT455 MT465 MT525B MT535 MT535B MT545 MT545B MT555B MT565 MT565B MT635 MT635B MT645 MT645B MT655 MT655B MT665 MT665B MT735 MT745 MT745B MT755 MT755B MT765

OPEN OPEN OPEN CLOSED (LS) OPEN CLOSED (LS) BOTH (a) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS) CLOSED (LS)

3046 3046 3046 2900 3046 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900

10 10 10 29 10 29 15/27.7 29 29 29/39 29 29/39 29/39 29/39 29/39 29/39 29/39 29/39 29/39 43.5 43.5 43.5 43.5 43.5 43.5

2 2 2 1 2 1 /1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3 3 3 2 3 2 /2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 2/1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 /2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 2/1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

13

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

CHALLENGER cont. MT765B MT835 MT835B MT845 MT845B MT855 MT855B MT865 MT865B MT875B

12/22/06

Hydraulic System Type

CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Maximum Pressure (PSI)

2900 2900 2900 2900 2900 2900 2900 2900 2900 2900

Page 14

Maximum Flow (GPM)

HM1C

43.2 43.5/59 43.5/59 43.5/59 43.5/59 43.5/59 43.5/59 43.5/59 43.5/59 43.5/59

1 1 1 1 1 1 1 1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1

*On all Challenger hydraulic systems, consult your tractor dealer for special plumbing instructions. Watch hydraulic temperature closely when using continuous duty equipment, such as hydraulic motors, to prevent overheating of the hydraulic system. (a) Consult Challenger to determine which type of hydraulic system this tractor has and what method of use for regulating oil flow. DEUTZ D3006 D4006 D4006A D4057 D4057A D4506 D4506A D4507 D4507A D5206 D5207 D5207A D5506 D6006 D6006A D6007 AFTER 1974 D6206 D6206A D6207 D6207A D6507 D6507C D6806 D6806A D7007 D7206 D7206A D7807 D7807C D8006 D8006 AFTER 1977 D8006A D8006A AFTER 1977 D9006 D9006A D10006 D10006 AFTER 1977 D10006A D10006A AFTER 1977 D13006 D13006 AFTER 1978 D13006A D13006A AFTER 1978 DX3.10 DX3.1A DX3.30 DX3.30A DX3.50 DX3.50A

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2490 2490 2490 2537 2537 2485 2485 2537 2537 2572 2500 2537 2490 2490 2490 2840 2485 2485 2537 2537 2500 2500 2940 2940 2500 2940 2940 2500 2500 2485 2485 2485 2485 2490 2490 2485 2485 2485 2572 2485 2485 2485 2485 2538 2538 2538 2538 2538 2538

7.2 6.4 6.4 10.6 10.6 9.2 9.2 10.6 10.6 7.2 9 11 9.2 9.2 9.2 9.33 7.5 9.2 11 11 9.7 9.7 9.2 9.2 10.6 9.2 9.2 11 11 8.6 9.5 8.6 9.5 11.3 11.3 8.6 10.5 10.4 10.4 10.8 11.5 10.9 9.5 11.6 11.6 13.5 13.5 13.5 13.5

3 2 2

2 3 3 3 3 2 2 3 3 2 2 3 2 2 2 2 2 2 3 3 3 3 2 2 3 2 2 3 3 2 1 2 1 3 3 2 3 3 3 3 3 1 1 3 3

2 2 3 3 2 2 3 3 2 3 3 3 3 3 3 2 2 2 2 3 3 2 3 3 2 2 3 2 3 2 2 2 3 2 2 2 2 2 2 2 2 2 1 1 1 1

3 3 3 3

CODE KEY

14

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 3 3 2 2 3 2 3 3 3 3 3 2 2 2 2 3 3 2 3 3 2 2 3 2 3 2 2 2 3 2 2 2 2 2

2 2 2 2

2 2 2 1 1 1 1

2 2 2 2

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

DEUTZ cont. DX3.70 DX3.70A DX3.90 DX3.90A DX4.70 DX4.70A DX6.30 DX6.30A DX6.50 DX6.50A DX7.10 DX7.10A DX90 DX90A DX110 DX140 DX160

12/22/06

Hydraulic System Type

9:37 AM

Page 15

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2538 2538 2538 2538 2538 2538 2538 2538 2538 2538 2538 2538 2485 2538 2485 2485 2485

17.7 17.7 17.7 17.7 19.5 19.5 24.8 24.8 24 24 27.9 27.9 14.7 14.7 14.7 18.2 18.2

CLOSED (LS)

2500

23

OPEN

1985

5.15

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

1985 2538 2538 2538 2538 2538 2538 2538 2538 2538 2500 2500 2500 2500 2500 2275 2275 2275 2500

6.4 11.6 13.5 13.5 17.7 17.7 19.6 24 24 27.3 22 22 22 22 23 24 24 23 23

1 1 1 1 1 1 1 1 1

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900

19.8 19.8/29 19.8/29 19.8/29 29 29 29 29 29 29 29 30 30 31 31 31

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CLOSED (LS) CLOSED (LS) CLOSED (LS)

2800 2500 2500

27.6 25.2 25.2

1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2 2 2 2 2 2 2 2 2 2 2 1 1 1

1 1 1 1

3 3 3 2 2

2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 1 1

1 1 1

1

2

2 2

1 1 1 1

2 2 2 1 1

DEUTZ ALLIS 4W305 5215HST 5220 (a) 5220HST 5230 (a) 6240 6250 6260 6265 6275 7085 7110 7120 7145 8010 8030 8050 8070 8550 9130 9150 9170 9190

(LS) (LS) (LS) (LS) (LS)

1

2 1 1

2 NOTHING RECOMMENDED NOTHING RECOMMENDED 2 NOTHING RECOMMENDED NOTHING RECOMMENDED 2 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 1 1

1 1 1 1 1

1

2 1 2 2 2 2 2 2

2 2 1 1

1

2 2 2 2 2 2 2 2 2

1 1 1 1 1

1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2

1 1 1

2 2 2

1 1 1

FENDT 409 410 411 412 711 712 714 716 815 817 818 918 920 924 926 930

CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

FORD & FORD NEW HOLLAND 276 756 836

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit..

15

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

FORD & FORD NEW HOLLAND cont. 836PS CLOSED (LS) CLOSED (LS) 846 856 CLOSED (LS) CLOSED (LS) 876 936 CLOSED (LS) CLOSED (LS) 946 956 CLOSED (LS) CLOSED (LS) 976 1000 OPEN OPEN 1100 1110 OPEN OPEN 1120 1156 CLOSED (LS) OPEN 1200 1210 OPEN OPEN 1220 1300 OPEN OPEN 1310 1320 OPEN OPEN 1500 1510 OPEN OPEN 1520 1600 OPEN OPEN 1700 1710 OPEN OPEN 1720 1900 OPEN 1910 OPEN 1920 OPEN OPEN 2000 2110 OPEN 2120 OPEN 2310 OPEN 2310 (a) CLOSED 2600 OPEN 2610 OPEN 2610 (a) CLOSED 2810 OPEN 2810 (a) CLOSED 2910 OPEN 2910 (a) CLOSED 3000 OPEN 3010 OPEN 3230 OPEN 3415 OPEN 3430 OPEN 3600 OPEN OPEN 3610 3610 (a) CLOSED 3830 OPEN 3910 OPEN 3910 (a) CLOSED OPEN 3930 4000 OPEN 4030 OPEN 4100 OPEN 4110 OPEN CLOSED 4110 (a) OPEN 4230 4430 OPEN 4600 OPEN OPEN 4600-SU 4610 OPEN 4610 (a) CLOSED 4630 OPEN 4835 OPEN

9:37 AM

Maximum Pressure (PSI)

2500 2500 2500 2500 2400 2400 2400 2400 1400 1850 1850 1850 2500 1850 1850 1850 2133 2133 2133 2133 2133 2133 1400 2133 2100 2133 2133 2133 2133 2500 2133 2500 2500 2500 2100 2000 2000 2500 2500 2500 2500 2500 2750 2100 2500 2100 2100 2000 2000 2700 2500 2500 2100 2500 2700 2500 2100 2000 2700 2700 2100 2100 2000 2100 2100 2750

Page 16

Maximum Flow (GPM)

25.2 25.2 25.2 25.2 24.5 24.5 24.5 24.5 4.2 2.9 4.1 4.7 27 2.9 4.3 4.7 4.3 6.3 6.4 4 6.6 6.4 4.2 5.3 7.8 7.8 5.9 8.6 7.8 4 8.6 9.3 7.7 13.6 8.5 8.5 13.6 7.7 13.6 7.7 13.6 5 8.6 7.7 6.5 7.7 8.5 8.5 13.6 11 7.7 13.6 7.7 5 11 8.5 8.5/14.1 13.6 11 11 8.5 8.5 8.5/14.1 13.6 8.5/14.1 14.5

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

1 1 1 1 1 1 1 1

1

3 3

3 3 3

3 2 3

2 /2 3 2 2

/1 3 /2 1

2 2 2 2 2 2 2 2 2 NOTHING RECOMMENDED 2 2 2 NOTHING RECOMMENDED 2 2 2 2 3 2 3 2 3 2 2 3 2 2 3 2 3 2 2 3 3 2 3 2 2 3 2 2 3 2 2 3 2 3 2 2 3 2 3 3 2 2 2 3 2 3 2 3 2 3 2 3 2 3 2 2 3 3 2 2 2 3 2 3 3 2 2/3 2 3 3 3 2 2 3 3/ 2/3 2 3/ 2/3 3

CODE KEY

16

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

1 1 1 1

2 2 2 2 2 2 2 2

1 1 1 1

1

2

1

2

2 2 2

3 2 3

2 /2

/1 3 2 2

/2

/2

/1 3 /1 1

/2

/2 2

/2 2

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

FORD & FORD NEW HOLLAND cont. OPEN 5000 5030 OPEN OPEN 5530 5600 OPEN (b) 5610 5635 OPEN CLOSED 5640 S, SL 5640 SLE CLOSED OPEN 5900 6530 OPEN OPEN 6600 6610 (b) OPEN 6635 6640 S, SL CLOSED CLOSED 6640 SLE 6700 OPEN (b) 6710 7000 OPEN CLOSED 7010 7530 OPEN OPEN 7600 7610 (b) OPEN 7700 7710 (b) CLOSED 7740 S, SL 7740 SLE CLOSED 7810 (b) 7840 SL CLOSED CLOSED 7840 SLE 8000 OPEN 8010 CLOSED 8160 CLOSED 8210 (b) 8240 SLE CLOSED 8260 CLOSED 8340 SLE CLOSED 8360 CLOSED 8530 CLOSED 8560 CLOSED 8600 OPEN 8630 (b) CLOSED 8670 8700 OPEN 8730 (b) 8770 CLOSED 8830 (b) 8870 CLOSED 8970 CLOSED 9000 OPEN 9030 CLOSED 9184 CLOSED 9280 CLOSED 9282 CLOSED 9384 CLOSED 9480 CLOSED CLOSED 9482 OPEN 9600 9680 CLOSED 9682 CLOSED 9684 CLOSED OPEN 9700 9880 CLOSED 9882 CLOSED 9884 CLOSED FW20 OPEN

(LS)

(LS)

(LS)

(LS)

(LS) (LS) (LS) (LS) (LS) (LS)

(LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Page 17

Maximum Pressure (PSI)

2500 2500 2700 2100 2100 2750 2500 2500 2100 2700 2100 2100 14.5 2500 2500 2100 2100 2500 2500 2700 2100 2100 2100 2100 2500 2500 2500 2500 2500 2500 2500 2755 2100 2500 2755 2500 2755 2500 2755 2500 2500 2750 2200 2500 2750 2500 2750 2750 2500 2300 2900 2400 2900 2900 2400 2900 2500 2400 2900 2900 2500 2400 2900 2900 2250

Maximum Flow (GPM)

HM1C

6 8.5/14.1 11.7 9.7 9.7/18.2 14.5 18 21 9 11.7 9.7 9.7/18.2

/1 2 2 2/ 1 1 1 3 2 2 2/

18 21 9.7 9.7/18.2 6 17.4 11.6 9.7 9.7/18.2 9.7 9.7/18.2 18 20 9.7/18.2 17.4 20 12 17.4 24 9.7/18.2 20 24 20 24 30.3 26 12 29 31 15.5 29 31 29 31 31 16 30 45 25/30 30 45 24/30 30 16 25/30 30 50 15.5 25/30 30 50 20

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 3/

/2

/2

1 1 2 2/

/2 2

1 2 2 2/ 2 2/ 1 1 2/ 1 1 2 1 1 2 1 1 1 1 1 1 2 1 1 3 1 1 1 1 1 3 1 1 1 1 1 1 1 3 1 1 1 3 1 1 1

/2 /2

/2

2

3 2/3 3 3 3/ 3 2 2 2 3 3 3/ 2 2 3 3/ 3 2 3 3 3/ 3/ 3/ 2 2 3/ 2 2 3 2 2 1 2 2 2 2 2 2 3 2 2 3 2 2 2 2 2 3 2 2 2 2 2 2 2 3 2 2 2 3 2 2 2

/2

2 1 1

/1 2 2 2/ 1 2 2 3 2 2/

1 1 1

1 1 /1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 2 1 1 2 1 1

2 2 2 2/ 2 2 2 2/ 2/ 2/ 2 2 2/ 2 2 2 2 2

/2

/2 2 1 1

/2 1 1 1 /2

/2 /2 /2

/2

1 1 /1 1 1 1 1

2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 3 2 2 2 2 2 2 2 3 2 2 2 3 2 2 2

1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 1 1 1 1 2 1 1 2 1 1 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

17

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

FORD & FORD NEW HOLLAND FW30 FW40 FW60 G170,G190,G210,G240 M100,M115,M135,M160 TB100 TB110 TB120 TG210 TG230 TG255 TG285 TJ280 TJ275 TJ330 TJ325 TJ375 TJ375HD TJ380 TJ375 Scraper TJ425 TJ430 TJ425 Scraper TJ450 TJ480 TJ450 Scraper TJ530 TJ500 TK76 Crawler TK80A TK80MA TK85 Crawler TK85M Crawler TK100A TL70,TL80,TL90,TL100 TM115, TM120,TM125 TM130, TM135 TM140 TM150 TM155 TM165 TM175 TN55D,S TN65D,S TN65F,TN70 TN70F TN75D,S TN75F,FA TN80F TN85FA TN90F TN95F TN95FA TS90 8X2 TS90 16X16 TS100 8X2 TS100 16X16 TS110 8X2 TS110 16X16 TV140 TW-5 TW-5 After July/1985 TW-10 TW-15 TW-15 After July/1985

12/22/06

Hydraulic System Type cont. OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN (b) OPEN OPEN (b)

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS)

9:37 AM

Page 18

Maximum Pressure (PSI)

Maximum Flow (GPM)

2250 2250 2250 2750 2750 2500 2500 2500 3250 3250 3250 3250 2800 2200 2800 2200 2200 2200 2800 2200 2200 2800 2200 2200 2800 2200 2800 2200 2755 2750 2750 2755 2755 2750 2750 2750 2750 2750 2750 2750 2750 2750 2750 2750 2750 2755 2750 2750 2755 2750 2750 2755 2750 2500 2500 2500 2500 2500 2500 3000 2500 2500 2200 2500 2500

20 20 20 24 20 9.7 9.7 9.7 38.6/68 38.6/68 38.6/68 38.6/68 33 40/75 33 40/90 40/90 40/90 33 55/90 40/90 33 55/90 40/90 33 55/90 33 35 12 11.9 11.9 12 12 11.9 14.5 28 28 28 28 28 30.5 31.7 12.4/16.9 12.4/16.9 12.4 12.4/16.9 16.9 12.4 12.4/16.9 12.4 16.9 16.9 12.4 18 21 18 21 18 21 30 16 25 16.2 15.3 24

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2 2 1 1 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 3 1 1 1 1 1 1 1 2/ 2/ 2 2/ 3 2 2/ 2 3 3 2 1 1 1 1 1 1 1 3 1 3 3 1

CODE KEY

18

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 2 2 2 2 2 2 2 2 3/ 3/ 3 3/ 3 3/ 3

1 1

2 2

1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2/2 2/2 2 2/2 3 2 2 2 3 3 2 2 2 2 2 2 2 2 3 2 3 3 2

1

1

1

1 1

1 1 1 1 1 1 1 /2 /2

2 2 2

3 2 2 2 2 2 2 2 2 3 2

1 1 1 1 1 1 1 2 1 2 2 1

1 1

1 1

1

1

1 1

1 1 1 1 1 1 1 /2 /2 /2 2 2 2 2 1 1 1 1 1 1 1 2 1 2 2 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Page 19

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

FORD & FORD NEW HOLLAND cont. OPEN 2200 15.5 3 TW-20 TW-25 OPEN 2500 15.3 3 (b) 2500 24 1 TW-25 After July/1985 TW-30 OPEN 2200 15.5 3 OPEN 2200 20 2 TW-30 After 1979 TW-35 OPEN 2500 20 2 (b) 2500 29 1 TW-35 After July/1985 COUNTRY SUPER 4 OPEN 2500 6 2 OPEN 2500 6.3 2 COUNTRY SUPER 6 (a) Series 10 tractors with closed center systems have the valves located at the rear of the tractor. Open center series 10 tractors have the valves located under the seat with hoses running back to couplers. (b) This type of closed center system uses a constant displacement pump. Contact Ford New Holland before operating a hydraulic-driven pump on this system. An auxiliary oil cooler may be required. HESSTON-FIAT 65-46 70-65 70-65C 70-75C 80-75C 95-55 130-90DT 160-90DT 180-90DT 466 & 466DT 566 & 566DT 580 & 580DT 665C 666 & 666DT 680 & 680DT 766DT 780 & 780DT 880-5 & 880-5DT 980 & 980DT 1180 & 1180DT 1380 & 1380DT 1580 & 1580DT 1880 & 1880DT 45-66 & 45-66DT 55-56 & 55-56DT 55-66 & 55-66DT 55-76 & 55-76FDT 60-66 & 60-66DT 60-76 & 60-76FDT 60-90 & 60-90DT 65-56 & 65-56DT 70-66 & 70-66DT 70-76 & 70-76FDT 70-76U 70-90 & 70-90DT 80-66 & 80-66DT 80-76 & 80-76DT 80-90 & 80-90DT 880-5 & 880-5DT 90-90 & 90-90DT 980 & 980DT 100-90 & 100-90DT 1180 TURBO 1180DT TURBO 130-90 & 130-90DT 1380 & 1380DT 140-90 & 140-90DT 1580 TURBO 1580DT TURBO 160-90 & 160-90DT 1880 & 1880DT

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2702 2700 2700 2700 2700 2700 2450 2450 2450 2700 2700 2702 2700 2700 2702 2702 2702 2702 2702 2488 2488 2488 2488 2702 2700 2702 2702 2702 2702 2702 2700 2702 2702 2702 2702 2702 2702 2702 2702 2702 2702 2702 2488 2488 2450 2488 2450 2488 2488 2450 2488

6.5 9 11 11 11 11 13.4 14.7 14.7 11 11 9.6 9 11 11 11 11 11 11 14.4 14.4 14.7 14.7 9 9 11 9 11 11 11 9 11 11 11 11 11 11 11 11 14 11 14 14.4 14.4 13.4 14.4 13.4 14.7 14.7 14.7 14.7

2 3 2 2 2 2 1 1 1 2 2 3 3 2 2 2 2 2 2 1 1 1 1 3 3 2 3 2 2 2 3 2 2 2 2 2 2 2 2 1 2 1 1 1 1 1 1 1 1 1 1

3 3 2 3

2 2 1 2

3 3 2 3

2 2 1 2 2 2

2 3 3

3 2 3 3 3 3 3 3 3 3 3 2 2 3 3 3 3 3 3 3 3 3 3 2 2 3 2 3 3 3 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

1

2 2 2

2 2 2 2

2

3 2 2 2 2 1 1 1 2 2

2 2 2 2 2 2 1 1 1 1

1

2 2 2

2 2 2 2

2 2 2 2

2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 1 2 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

19

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Maximum Pressure (PSI)

Page 20

Maximum Flow (GPM)

HM1C

HESSTON–FIAT cont. 180-90 & 180-90DT F110 & F110DT F130 & F130DT

OPEN OPEN OPEN

2450 2670 2670

14.7 14.9 14.9

1 1 1

INTERNATIONAL HARVESTER 100, HYDRO 140 234 234, HYDRO 244 254 274 284 354 364 364, After 1977 384 454 464 464, 1975 Models 464, After 1975 484 544 574 574, After 1975 584 600DT 604 656 664 666 674 674, After 1975 684 686 HYDRO-70 756 766 766, After 1975 784 HYDRO-84 HYDRO-86 HYDRO-86 After 11/1980 826 HYDROSTATIC 826 GEAR DRIVE 856 884

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED (LS) OPEN OPEN OPEN OPEN

2000 1200 1920 1920 1995 1995 1750 1750 2400 2400 2400 2400 2300 2300 2500 2500 2500 1600 2500 2500 2500 2150 2000 2000 1600 1600 2500 2500 2500 1550 1350 1550 2000 2000 2500 2500 1550 1350 1550 2000 2000 2000

13 5 3.4 3.4 4.1 4.2 5.7 6 6 6 9 9 9 9 9 10.5 12 15/8.5 9 9.5 9.5 5.8 13 15/8.5 16/8.5 15/8.5 9 10.5 10.5 15/8.5 15/8.5 12 12 13 10.5 10.5 15/8.5 18 12 12 12 13

2

2 3/ 3/ 3/ 3 2 2 3/ 3/ 2 2 2 2 2 3/ 3 2 2 2 2

886 (a) 886, After 11/1980 966 966, After 1975 986 (a) 986, After 1978 (a) 986, After 11/1980 HYDRO-186(a) HYDRO-186 after 11/1980 1026 1066 1086 (a) 1086, After 1977 (a) 1086, After 11/1980 1456 1466 1486 (a) 1486, After 1977 (a)

OPEN CLOSED OPEN OPEN OPEN OPEN CLOSED OPEN CLOSED OPEN OPEN OPEN OPEN CLOSED OPEN OPEN OPEN OPEN

2250 2650 2000 2000 2250 2250 2650 2250 2650 2000 2000 2450 2450 2650 2000 2250 2450 2450

13 18 12 13 12 13 18 12 18 12 12 13 12 18 12 12 13 13

2 1 2 2 2 2 1 2 1 2 2 2 2 1 2 2 2 2

(LS)

(LS) (LS)

(LS)

3 3 3 3 3 2 2 3/ 3 2 2

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

3 3 3

3 2 NOTHING RECOMMENDED NOTHING RECOMMENDED 2 2 2 2 3 2 3 2 3 2 2 2 2 2 3 3 3/2 2 3 3 2 3 3/2 3/2 3/2 2 1 1 3/2 3/2 3 3 3 3 3 /3 3 3 3 3 3

CODE KEY

20

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

3 2 3 3 3 3 2 3 2 3 3 3 3 2 3 3 3 3

2 2 2

1 1 1

2 2 2

2

2/

2/ 2/ 2/

2/ 2/

3 3 3 3 3 2 2 3/ 3

2 3/ 3/ 3/ 3

3/ 3/ 2 2 2

2/

2/ 2/ 2/

2/ 2/

3/ 2 2 2 2 1

1 1

1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1

1 1

1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Page 21

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

I.H. cont. 1486, After 11/1980 CLOSED (LS) 2650 18 1 OPEN 2250 13 2 1566 1568 OPEN 2250 13 2 OPEN 2450 13 2 1586 (a) 1586, After 1977 (a) OPEN 2450 13 2 CLOSED (LS) 2650 18 1 1586, After 11/1980 3088 OPEN 2250 15 3 OPEN 2250 15 3 3288 3388 CLOSED (LS) 2650 18 1 CLOSED (LS) 2600 18.6 1 3488 3588 CLOSED (LS) 2650 18 1 CLOSED (LS) 2600 18.6 1 3688 3788 CLOSED (LS) 2650 18 1 OPEN 2000 17 2 4166 4186 OPEN 2000 18 2 OPEN 2000 22 2 4366 4386 OPEN 2000 16 3 OPEN 1800 16 3 4568 4586 OPEN 2000 19 2 OPEN 2000 19 2 4786 5088 CLOSED (LS) 2600 25 1 2600 25 1 CLOSED (LS) 5288 5488 CLOSED (LS) 2600 25 1 CLOSED (LS) 2600 18.6 1 6388 6588 CLOSED (LS) 2600 18.6 1 CLOSED (LS) 2600 18.6 1 6788 2600 26 1 7288 CLOSED (LS) 7388 OPEN 2000 22 2 7488 CLOSED (LS) 2650 26 1 OPEN 2000 22 2 7588 7788 OPEN 2250 22 2 (a) For tractors built prior to November 1980, International Harvester Service Bulletin S-3436 dated March 1977 advises that continuous hydraulic demand on the remote outlet valves such as that created by hydraulic motors, can cause damage to the tractor hydraulic system. In gear-driven tractors (86 series, 2 wheel drive), the MCV pump charge circuit would not be receiving its normal flow; and in Hydrostatic drive tractors, the oil cooler circuit would

2 3 3 3 3 2 3 3 2 2 2 2 2

3 3

1

1 2 2 1 1 1 1 1 1 1

2 2 2 2 2 2 3 3 2 2 2 2 2

1

2 2 2 3 3

2 2 2 2 2 2 2

2 2 1 1 1 1 1 1 1 1 1

2

1

2

2 2 2 2 2 2 2 2 2

1 2 2 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1

2 1 2 2

not be receiving its normal flow.

JOHN DEERE 650 655 670 750 755 770 790 990 820 830 850 850 AFTER 1979 855 870 950 950 AFTER 1979 955 970 1020 1020 AFTER 1979 1050 1050 AFTER 1979 1070 1250 1450 1520 1530 1650

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED OPEN

1800 2050 2050 2050 2050 2050 2050 2262 2100 2100 2100 2100 2050 2250 2100 2100 2500 2250 2250 2250 2000 2030 2250 2250 2250 2250 2250 2250

4.5 4 5.5 5.8 5.6 5.6 5.6 8.5 6.5 6.5 5 6.5 5.6 8.1 5 6.5 7.2 8.7 6.5 12 5.7 7 9 15.8 15.2 6.5/12 6.5/12 14.5

2 2 2 2 2 2 2 3 3 3 2 3 2 2 3 3 3 3 2 3 3 3 3

1

3 3 3 3 3 2 2 2 2 3 2 2 2 2 2 2 3 2 2 3 3 2 2 3

3

2 2

3 3

2 2

2

1

2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

21

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

JOHN DEERE cont. 2020 2030 2040 (a) 2040 (b) 2150 2155 2240 2255 2350 2355 2440 2520 2550 2555 2630 2640 2750 2755 2855N 2840 2940 2950 2955 3020 3055 3150 3155 3255 4000 4020 4030 4040 4050 4055 4100 4110 4115 4200 4210 4230 4240 4250 4255 4300 4310 4320 4400 4410 4420 4430 4440 4450 4455 4500 4510 4555 4560 4600 4610 4620 4630 4640 4650 4710 4755 4760

12/22/06

Hydraulic System Type

CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED OPEN OPEN CLOSED OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED OPEN OPEN CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED

9:37 AM

Maximum Pressure (PSI)

2250 2250 2100 2250 2250 2320 2250 2320 2250 2320 2250 2250 2250 2320 2250 2250 2250 2320 2320 2250 2250 2250 2320 2250 2320 2320 2320 2320 2250 2250 2250 2250 2320 2530 2418 2418 2418 2125 2125 2350 2200 2320 2530 2500 2500 2250 2500 2500 2530 2250 2200 2320 2530 2500 2500 2530 2320 2500 2500 2250 2250 2200 2320 2500 2530 2530

Page 22

Maximum Flow (GPM)

6.5/12 6.5/14 6.5 12 13 13 12 13/23 13/23 13/23 18-Dec 14 13/23 13/23 39069 39069 13/23 13/23 21 14 14 23 21 14 22 22 22 22 18 18 14 18 26 26.5 5.1 5.1 5.1 7.3 7 18 20 26 26.5 8.3 8.6 18 8.3 8.6 18 18 26 26 26.5 9.9 10.6 29.5 29.5 10.3 10.6 18 18 20 34 10.6 30 30

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

3

/1 /1 /1

/1 /1 /1 /1

1

1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 3 1 1 1 1 3 3 1 3 3 1 1 1 1 1 2 2 1 1 2 2 1 1 1 1 2 1 1

CODE KEY

22

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 2 2

2 2 2 2 3 2 2

2

2 2 2 2 2 2 2 2

1

2 2 2

1

1

2 2 2 2

1

2 1 1

1

1

1 1

1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1

1

1

1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

JOHN DEERE cont. 4840 4850 4955 4960 5105 5020 5200 5205 5210 5220 5225 5300 5303 5310 5310N 5320 5320N 5325 5400 5400N 5403 5410 5420 5425 5500 5500N 5510 5510N 5520 5525 6030 6110,6110L 6120 6200 6210,6210L 6215 6220 6300 6310,6310L,6310S 6320 6320L 6400 6403 6405 6410,6410L,6410S 6415 6420 6420L 6420S 6500 6510,6510L,6510S 6520 6603 6605 6615 6620 6715 6820 6920,6920S 7010 7020 7200 7210 7220 7320

12/22/06

Hydraulic System Type

CLOSED CLOSED CLOSED CLOSED OPEN CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

9:37 AM

Page 23

Maximum Pressure (PSI)

Maximum Flow (GPM)

2200 2320 2530 2530 2990 2250 2750 2990 2750 2755 2800 2750 2800 2750 2750 2755 2755 2900 2750 2750 2800 2855 2755 2800 2750 2750 2855 2855 2755 2800 2250 2900 2900 2900 2900 2500 2900 2900 2900 2900 2900 2900 2750 2500 2900 2500 2900 2900 2900 2900 2900 2900 2750 2500 2500 2900 2500 2900 2900 2900 2000 2900 2900 2900 2900

26 34 29.5 29 10.9 18 11.4 10.9 11.4 11.4 13.5 11.4 11 11.4 11.4 18.2 18.2 13.5 11.4 11.4 11 15.9 15.9 18.4 11.4 16.4 15.9 15.9 15.9 18.4 18 18/25 25.4/18.9 16/25 18/25 17.5 25.4/18.9 16/25 18/25 25.4/18.9 25.4 16/25 12 17.5 18/25 17.5 25.4/18.9 25.4 25.4 18.8 30.2 25.4 15 17.5 17.5 25.4 17.5 25.4 25.4 33 14/18 16/25.4 15.9/26.2 26.7 26.7

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

1 1 1 1 2 1 2 2 2 2 2 2 2 2 2

2 2 2 2 3 2 3 3 3 3 3 3 3 3 3 2 2

2 2 2 2 3 3

1 1 3 3 3 3 3 3

2 2 3 3 3 3

1 1

2 2 1

3 3 3 3 2

1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 /1 /1 I I

1 1

2 2

1 1

2

2 2 1

2

2 2 2 2 1

2 2 2 2 3 3 2 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 2 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 /1 /1 1 1

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

23

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

JOHN DEERE cont. 7400 CLOSED (LS) CLOSED (LS) 7405 7410 CLOSED (LS) CLOSED (LS) 7420 7510 CLOSED (LS) CLOSED (LS) 7520 7600 CLOSED (LS) CLOSED (LS) 7610 7700 CLOSED (LS) CLOSED (LS) 7710 7720 CLOSED (LS) CLOSED (LS) 7800 7810 CLOSED (LS) CLOSED (LS) 7830 7920 CLOSED (LS) CLOSED (LS) 8100,8100T 8110T CLOSED (LS) CLOSED (LS) 8120/8120T 8130 CLOSED (LS) CLOSED (LS) 8200,8200T 8210,8210T CLOSED (LS) CLOSED (LS) 8220/8220T 8230 CLOSED (LS) CLOSED (LS) 8300,8300T 8310,8310T CLOSED (LS) CLOSED (LS) 8320/8320T 8330 CLOSED (LS) 8400,8400T CLOSED (LS) 8410,8410T CLOSED (LS) CLOSED (LS) 8420/8420T 8430 CLOSED 8440 CLOSED 8450 CLOSED 8520/8520T CLOSED (LS) 8530 CLOSED (LS) 8560 CLOSED 8570 CLOSED 8630 CLOSED 8640 CLOSED 8650 CLOSED 8760 CLOSED 8770 CLOSED 8850 CLOSED 8870 CLOSED 8960 CLOSED 8970 CLOSED 9100 CLOSED (LS) CLOSED (LS) 9120 9200 CLOSED (LS) 9220 CLOSED (LS) 9300,9300T CLOSED (LS) 9320/9320T CLOSED (LS) CLOSED (LS) 9400,9400T 9420/9420T CLOSED (LS) 9520/9520T CLOSED (LS) 9620 CLOSED (LS) (a) Tractor serial numbers through 266749. (b) Tractor serial numbers beginning with 266750.

9:37 AM

Page 24

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

2900 2750 2900 2900 2900 2900 2900 2900 2900 2900 3046 2900 2900 2900 3046 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900 2200 2250 2250 2900 2900 2530 2530 2250 2250 2250 2530 2530 2250 2530 2530 2530 2900 2900 2900 2900 2900 2900 2900 2900 2900 2900

16/25.4 17.5 15.9/26.2 26.7 26 26.7 25.4 33 25.4 26 30 25.4 26 32/45 30 29 33.5 33.5/42.5 31.7 29 30 33.5/42.5 31.7 29 33.5 33.5/42.5 31.7 29 33.5 33.5/42.5 18 18 28.5 33.5/42.5 31.7 33.3 33.3 18 18 28.5 33.3 33.3 44.4 33.3 33.3 33.3 35/44 44/48 35/44 44/48 35/44 44/48 35/44 44/48 48 48

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

CODE KEY

24

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

/2 1 /1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

/1 1 /1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Page 25

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

KUBOTA M105X M125X M4800 M4900 M5700 M6800 M8200

OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2915 2915 2770 2770 2770 2770 2884

18 20.6 17 11 11 11 11/17

2 2 2

3 2 2 2 2/3

/2

1 1 1 3 3 3 3/

/1

2 2 3 2 2 2 2/3

1 1 2

/2

MASSEY-FERGUSON * SEE FOOTNOTES FOR ALL MODELS MF130-D MF135-G MF135-D MF150-G MF150-D MF154 MF165-G MF165-G aux. MF165-G After 1972 MF165-G After 1972 aux. MF165-D MF165-D aux. MF165-D After 1972 MF165-D After 1972 aux. MF174 MF175-G MF175-G aux. MF175-G After 1972 MF175-G After 1972 aux. MF175-D MF175-D aux. MF175-D After 1972 MF175-D After 1972 aux. MF180-G MF180-G aux. MF180-G After 1972 MF180-G After 1972 aux. MF180-D MF180-D aux. MF180-D After 1972 MF180-D After 1972 aux. MF184-4 MF194 MF203 MF205 MF205-4 MF210 MF210-4 MF220 MF220-4 MF230-D MF230-G MF231 MF235-D MF235-D aux. MF235-E MF235-E aux. MF235-G MF235-G aux. MF240 MF241 MF243 MF245-D MF245-D aux. MF245-G

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED OPEN OPEN OPEN OPEN OPEN OPEN CLOSED OPEN OPEN CLOSED OPEN CLOSED

2000 3000 3000 3000 3000 2418 3000 3000 3000 3000 3000 3000 3000 3000 2418 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 2418 2418 2600 1700 1700 1700 1700 1700 1700 3000 3000 2320 3000 3000 3000 3000 3000 3000 2540 2500 2500 3000 3000 3000

8 8 8 8 8 9.2 8 8 8 10 8 8 8 10 9.8 8 8 8 10 8 8 8 10 8 8 8 10 8 8 8 10 7.4 9.4 8 5 5 5.4 5.4 5.4 5.4 8 8 4 4.5 10 4.5 10 4.5 10 4 4.4 9.5 4.5 10 4.5

3 3 3 3 3 3 3 3 3 2 3 3 3 2 2 3 3 3 2 3 3 3 2 3 3 3 2 3 3 3 2 3 2 3 2 2 2 2 2 2 3 3 2 2 2

2 2 2 2 2 2 2 2 2 3 2 2 2 3 3 2 2 2 3 2 2 2 3 2 2 2 3 2 2 2 3 2 3 2

3

2

2 2

2

2

2

2 2

2 2

3

2

3

2

3

2

3

2

3

2

2 2 2 2 2 2 2 2 2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

25

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

M.F. cont. * MF245-G aux. MF250 MF253 MF254 MF255-D MF255-D aux. MF255-G MF255-G aux. MF261 MF263 MF265-D MF265-D aux. MF270 MF271 MF274 MF275-D MF275-D aux. MF281 MF283 MF283 aux. MF285 MF290 MF294 MF298 MF360 MF362 MF374 MF374S MF375 MF383 MF384 MF390 MF390T MF393 MF394 MF394S MF396 MF398 MF399 MF451 MF471 MF481 MF650 MF660 MF670 MF680 MF690 MF698 MF699 MF1080-D MF1085 MF1100-D MF1105 MF1130-D MF1135 MF1150-D MF1155 MF1160 MF1180 MF1190 MF1210 MF1210H MF1220 MF1220H MF1230

12/22/06

Hydraulic System Type

OPEN BOTH (a) CLOSED OPEN CLOSED OPEN CLOSED OPEN CLOSED OPEN CLOSED OPEN OPEN BOTH (a) OPEN CLOSED OPEN OPEN CLOSED OPEN CLOSED BOTH (a) OPEN OPEN BOTH (a) BOTH (a) OPEN OPEN BOTH (a) CLOSED OPEN BOTH (a) BOTH (a) CLOSED OPEN OPEN CLOSED BOTH (a) BOTH (a) OPEN OPEN OPEN CLOSED (LS) CLOSED (LS) BOTH (a) CLOSED (LS) BOTH (a) BOTH (a) BOTH (a) CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

9:37 AM

Maximum Pressure (PSI)

3000 2000 2550 2418 3000 3000 3000 3000 3200 2500 3000 3000 2500 2500 2418 3200 2500 2600 3000 3000 3200 2500 2400 2400 2500 2500 2500 2418 2500 3000 2500 2500 2500 3200 2500 2418 3200 2500 2500 2700 2700 2700 3000 3000 2725 3000 2725 2725 2725 3100 3100 2100 2100 2100 2100 2100 2100 2275 2417 2417 2130 2130 2130 2130 2130

Page 26

Maximum Flow (GPM)

10 14-Apr 4/13.7 9.2 4 10 4 10 3.96 9.5 4 10 10.3 9.5/17 9.4 4 10.3 10 4.4 10 7 9.5 9.5 9.5 14 13.7 11.2 11.4 16.7 4.4 11.2 16.7 16.7 7.2 11.2 11.4 9.5 16.7 16.7 9.5 11.1 11.1 13 15.8 9.5/17 15.8 9.5/17 9.5/17 9.5/17 7 7 20 20 20 20 20 20 8.2 8.2 8.2 5.2 5.2 5.2 5.2 6

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 2/ 2/ 2

26

2

2

3

2

3

2

3

2

3 3/3 3 3

2 2/3 2 2

3 3 3 3 2 3 3 3 3 3 3 3 3

2 2

2 2 2 2 2 2 2 2 2/3 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 3

2

2

2 2 2 2 2 2 2 3

2

2 2

2 3 3

2 2

2 2 3 3 3 2 2 2 3 3 2 2 2 3 1 2/3 1 2/3 2/3 2/3 3 3 1 1 1 1 1 1 3 3 3 2 2 2 2 2

CODE KEY (1) (2) (3) (LS)

3 /3 /3 3

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

3 3 3 2 3 3 3 3 3 3 3 3 2 2 3/2 2 3/2 3/2 3/2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3

2 2

/1

2 2 2 3 3 2 2 2 3 2 2/3 2 2/3 2/3 2/3

2 2 2 2 2 2

2 2

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

M.F. cont. * MF1230H MF1240 MF1250 MF1260 MF1500-D MF1505 MF1800-D MF1805 MF2225 MF2235 MF2675 MF2700 MF2705 MF2745 MF2775 MF2800 MF2805 MF3050 MF3060 MF3070 MF3075 MF3090 MF3120 MF3120T MF3140 MF3315GE MF3315S MF3315V MF3330F MF3330GE MF3330S MF3330V MF3340F MF3340GE MF3340V MF3350F MF3350GE MF3355F MF3355GE MF3505 MF3525 MF3545 MF3630 MF3645 MF3650 MF3660 MF3670 MF3680 MF3690 MF3745 MF3845 MF3945 MF4225 MF4235 MF4243 MF4245 MF4253 MF4255 MF4263 MF4270 MF4325 MF4335 MF4345 MF4355 MF4360

12/22/06

Hydraulic System Type

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

9:37 AM

Page 27

Maximum Pressure (PSI)

Maximum Flow (GPM)

2130 2130 2130 2130 2400 2400 2400 2400 2250 2250 2250 2250 2250 2250 2250 2250 2250 2610 2610 2610 2610 2610 2610 2610 2610 2610 2175 2610 2610 2610 2175 2610 2175 2610 2610 2175 2610 2175 2610 2538 2538 2538 2538 2418 2538 2610 2540 2538 2540 2418 2418 2418 3046 3046 3046 3046 3046 3046 3046 3046 3046 3046 3046 3046 3046

6 6.7 6.7 6.7 20 20 20 20 14 14 14 14 14 14 14 14 14 13.2 13.2 13.2 13.2 13.2 13.2 13.2 13.2 11.6/15.3 11.6/15.3 11.6/15.3 13.7/15.3 11.6/15.3 11.6/15.3 11.6/15.3 13.7/15.3 13.7/15.3 13.7/15.3 13.7/15.3 13.7/15.3 13.7/15.3 13.7/15.3 14 14 14 14 9.5 14.4 14.1 13.2 14.1 13.2 9.5 9.5 9.5 10 10 10 10 10 10 10 10 10/17.4 10/17.4 10/17.4 10/17.4 10/17.4

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

2 3 3 3

3 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 1 1 1 1 2 1 1 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2/ 2/ 2/ 2/ 2/

/2 /2 /2 /2 /2

2 2 2 2 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3/3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3/ 3/ 3/ 3/ 3/

2 2 2 2 2 2 2 2 2

/2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 2 2 2 2 2 2 2

/1 /1 /1 /1 /1

1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 2/3 1 1 1 1 2 1 1 2 1 2 2 2 2 2 2 2 2 2 2 2 2 2/ 2/ 2/ 2/ 2/

2 2 2 2 2 2 2 2 2

/2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 /2 2 2 2 2 2 2 2

/2 /2 /2 /2 /2

/1 /1 /1 /1 /1

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

27

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Maximum Pressure (PSI)

Page 28

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

M.F. cont. * OPEN 3046 10/17.4 2/ /2 3/ /1 2/ MF4370 MF4800 OPEN 2250 20 2 OPEN 2500 20 2 MF4840 MF4880 OPEN 2500 20 2 OPEN 2500 20 2 MF4900 MF5340 OPEN 2610 17.4 3 2 1 3 OPEN 2610 17.4 3 2 1 3 MF5355 MF5435 OPEN 3050 15 3 3 2 3 OPEN 3050 15 3 3 2 3 MF5445 MF5455 OPEN 3050 15 3 3 2 3 OPEN 3050 15 3 3 2 3 MF5460 MF5460SA OPEN 3050 26 2 OPEN 3050 15 3 3 2 3 MF5465 MF5470SA OPEN 3050 26 2 OPEN 3050 26 2 MF5475SA MF6150 OPEN 2610 14.9 3 3 2 3 OPEN 2610 14.9 3 3 2 3 MF6170 MF6180 OPEN 2610 14.9 3 3 2 3 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 MF6255 MF6265 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 MF6270 MF6280 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 MF6280 MF6290 BOTH (a) 2900 15/27.7 3/1 3/2 2/1 3/2 CLOSED (LS) 3000 31.7 1 2 1 2 MF6350 MF6360 CLOSED (LS) 3000 31.7 1 2 1 2 2 1 2 1 2900 26.4 MF6445 CLOSED (LS) MF6455 CLOSED (LS) 2900 26.4 1 2 1 2 CLOSED (LS) 2900 26.4 1 2 1 2 MF6460 MF6465 CLOSED (LS) 2900 26.4 1 2 1 2 MF6470 CLOSED (LS) 2900 26.4 1 2 1 2 MF6475 CLOSED (LS) 2900 26.4 1 2 1 2 MF6480 CLOSED (LS) 2900 26.4 1 2 1 2 MF6485 CLOSED (LS) 2900 29 1 2 1 2 MF6490 CLOSED (LS) 2900 29 1 2 1 2 MF6495 CLOSED (LS) 2900 29 1 2 1 2 MF7465 CLOSED (LS) 2900 29 1 2 1 2 MF7475 CLOSED (LS) 2900 29 1 2 1 2 MF7480 CLOSED (LS) 2900 29 1 2 1 2 MF7485 CLOSED (LS) 2900 29 1 2 1 2 MF7490 CLOSED (LS) 2900 29 1 2 1 2 2 1 2 CLOSED (LS) 2900 29 1 MF7495 MF8120 CLOSED (LS) 2600 28 1 2 1 2 MF8140 CLOSED (LS) 2900 26 1 2 1 2 MF8150 CLOSED (LS) 2900 26 1 2 1 2 MF8160 CLOSED (LS) 2900 26 1 2 1 2 MF8220 CLOSED (LS) 2900 29/39 1 2 1 2 MF8240 CLOSED (LS) 2900 29/39 1 2 1 2 MF8245 CLOSED (LS) 2900 29/39 1 2 1 2 MF8250 CLOSED (LS) 2900 29 1 2 1 2 MF8260 CLOSED (LS) 2900 29/39 1 2 1 2 MF8270 CLOSED (LS) 2900 29/39 1 2 1 2 MF8280 CLOSED (LS) 2900 29/39 1 2 1 2 MF8450 CLOSED (LS) 2900 39.6 1 2 1 2 MF8460 CLOSED (LS) 2900 39.6 1 2 1 2 CLOSED (LS) 2900 39.6 1 2 1 2 MF8470 MF8480 CLOSED (LS) 2900 39.6 1 2 1 2 * On all Massey-Ferguson hydraulic systems, consult your tractor dealer for special plumbing instructions. Watch hydraulic temperature closely when using continuous duty equipment, such as hydraulic motors, to prevent overheating of the hydraulic system. (a) Consult Massey-Ferguson to determine which type of hydraulic system this tractor has and what method to use for regulating oil flow.

CODE KEY

28

(1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

/2 2 2 2 2

/1

2 2 2 2 2 2 2 2 2 2 2 2 2 2/1 2/1 2/1 2/1 2/1 2/1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Page 29

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

16 16 15.5 15.5 15.5 15.5 14 14 15.8 15.8 15.8 15.8 15.8 15.8 15.8 15.8 28.7 28.7 28.7 28.7 28.7 28.7 28.7 28.7 25 31.9 31.9 25

3 3 3 3 3 3 1 1 3 3 3 3 3 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

McCORMICK C50 C60 C70 C80 C90 C100 CX50 CX60 CX70 CX75 CX80 CX85 CX90 CX95 CX100 CX105 MC80 MC90 MC100 MC115 MC120 Power 6 MC135 Power 6 MTX110 MTX125 MTX140 MTX155 MTX175 MTX200

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 2500 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 1 1

2 2

1 3

2 2

MINNEAPOLIS MOLINE* JET STAR THREE OPEN 1550 14 1 3 U302 OPEN 1700 15 3 3 M670 SUPER OPEN 2000 20 2 G350 OPEN 2100 5.75 2 G450 OPEN 2133 5.75 2 NOTHING RECOMMENDED G550 OPEN 2050 NA NOTHING RECOMMENDED NOTHING RECOMMENDED G750 OPEN 2050 NA NOTHING RECOMMENDED G850 CLOSED 2200 18 1 2 G940 CLOSED 2000 18 1 2 CLOSED 2000 18 1 2 G950 G1050 CLOSED 2000 18 1 2 G1350 CLOSED 2000 18 1 2 2 CLOSED 2000 20 1 A4T 1400 A4T 1600 CLOSED 2000 20 1 2 *Hydraulic oil coolers are not standard on these models. An oil cooler is required for continous duty sprayer pump operation. OLIVER* 1700 NA NOTHING RECOMMENDED OPEN 550 NOTHING RECOMMENDED 4.5 2 1700 1255 OPEN 1565 OPEN 2130 5.75 2 1355 OPEN 2200 5.75 2 1365 OPEN 2130 5.75 2 1555 OPEN 2050 11 2 3 OPEN 2050 11 2 3 1655 18 1 2 2200 CLOSED 1755 1855 CLOSED 2200 18 1 2 1955 CLOSED 2200 18 1 2 3 2 11 2050 OPEN 2050 2150 OPEN 2050 11 2 3 2155 CLOSED 2000 18 1 2 1655 CLOSED 2000 20 1 2 *Hydraulic oil coolers are not standard on these models. An oil cooler is required for continous duty sprayer pump operation.

2

2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

29

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Maximum Pressure (PSI)

Page 30

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

STEIGER BEARCAT BEARCAT ST-25 BEARCAT ST220 BEARCAT PT225 BEARCAT IV CM225 BEARCAT IV KM225 COUGAR COUGAR DTA-280 COUGAR ST250 COUGAR ST251 COUGAR ST270 COUGAR PT270 COUGAR IV CM250 COUGAR IV CM280 COUGAR IV CS280 COUGAR IV KM280 COUGAR IV KS280 COUGAR CM-150 COUGAR PTA251 (a) COUGAR PTA270 (a) COUGAR ST280 (a) COUGAR PTA280 (a) COUGAR 1000 COUGAR CR1225 (b) COUGAR KR1225 (b) COUGAR CR1280 (b) COUGAR KR1280 (b) LION 1000 PANTHER PTA297 PANTHER ST310 PANTHER ST320 PANTHER CS325 PANTHER ST325 PANTHER KS325 PANTHER III PTA325 (a) PANTHER IV CM325 PANTHER IV KM325 PANTHER SM-325 PANTHER PT350 PANTHER ST350 PANTHER IV CM360 PANTHER CS-360 PANTHER IV KM360 PANTHER KS360 PANTHER CP1325 PANTHER KP1325 PANTHER CP1360 PANTHER KP1360 PANTHER CP1400 PANTHER KP1400 PANTHER PTA310 (a) PANTHER 1000 PUMA SUPER WILDCAT TIGER TIGER ST450 TIGER ST470 TIGER IV KP525 WILDCAT RC210 WILDCAT ST210 WILDCAT 1000 9330 9350 9370

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED

(LS) (LS) (LS) (LS)

(LS) (LS) (LS) (LS) (LS) (LS)

(LS) (LS) (LS)

2000 2250 2250 2250 2250 2250 2000 2250 2250 2250 2250 2250 2550 2550 2550 2550 2550 2550 2550 2550 2550 2550 2500 2500 2500 2500 2500 2500 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2250 2500 2500 2500 2500 2500 2500 2250 2500 2500 2000 2000 2250 2250 2250 2250 2250 2320 2900 2900 2900

22 20 20 20 20 20 22 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 27 30 30 30 30 27 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 20 27 27 24 25 25 25 25 20 20 27 28 30 30

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1

2 2 2 2 2 2

30

1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2

1 1 1 1 1 1

2 2

1 1

2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 1 1 1 1

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

1 1 1 1 1 1

2 2

2 1 1

CODE KEY (1) (2) (3) (LS)

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 2 1 1 2 2 2 2 2 2 2

2 2 2 2

1 1 1

2 2 2 2

1 1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

9:37 AM

Hydraulic System Type

Page 31

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

STEIGER Cont. CLOSED (LS) 2900 30 1 2 1 9380 9390 REMOTE 1 & 2 CLOSED (LS) 2900 30 1 2 1 OPEN 2900 30 2 9390 REMOTE 3 & 4 QUADTRAC CLOSED (LS) 2900 31 1 2 1 CLOSED (LS) 2900 40/55 1 2 1 STX275 STX325 CLOSED (LS) 2900 40/55 1 2 1 CLOSED (LS) 2900 40/55 1 2 1 STX375 STX425 CLOSED (LS) 2900 40/55 1 2 1 CLOSED (LS) 2900 40/55 1 2 1 STX450 STX500 CLOSED (LS) 2900 42/57 1 2 1 Steiger does not recommend use of continuous duty equipment without flow divider or auxiliary cooler. Coolers are available for older model (a) Series III tractors available with flow divider kit. Standard output 9 GPM. Optional output 18 GPM. (b) Each outlet has flow control adjustability from 3-25 or 30 GPM. VALTRA BH140 BH160 BH180 BM100 BM110 BM120 C90 C100 C110 C120 C130 C150 M120 M130 M150 S240 S280 T120 T130 T140 T160 T170 T180 T190 XM130 XM150 6200 6250 6300 6350 6400 6550 6850 8050 8150 8350 8550 8750 8950

OPEN OPEN OPEN OPEN OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

(LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS) (LS)

2610 2610 2610 2610 2610 2610 2842 2842 2842 2842 2842 2842 2842 2842 2842 2900 2900 2842 2842 2842 2842 2842 2842 2842 2842 2842 2755 2755 2755 2755 2755 2755 2755 2900 2900 2900 2900 2900 2900

21 21 21 13.6 13.6 13.6 24 24 24 24 24 24 24 24 24 39 39 24 24 24 24 24 24 24 24 24 19 19 19 19 19 19 19 19 19 19 19 19 19

1700 2000 1750 1750 2000 2500 2500 2250

12.5 16.5 12.5 12.5 16.5 14 15 15

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 2 2 3 3 3

2 2

1 1 2

2 2 2 2 2 2 2 tractors.

1 1 1 1 1 1 1

2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2 2 2 2 2 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2

VERSATILE 118 118 125 145 145 150 150 150

After 1971

After 1971 After 1976 Series II

OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2 3 2 2 3 1 3 3

3 2 3 3 3 3

2 2 2 2

2 3 2 2 3 1 3

2

2 2 2 2

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

31

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

9:37 AM

Maximum Pressure (PSI)

Hydraulic System Type

Page 32

Maximum Flow (GPM)

VERSATILE cont. CLOSED (LS) 2800 27.6 256 276 CLOSED (LS) 2800 27.6 OPEN 2000 16 300 500 OPEN 2300 24 OPEN 2400 23.2 555 700 OPEN 2000 24 OPEN 2300 25 700 Series II 750 Series II OPEN 2300 23.5 CLOSED (LS) 2400 25 756 800 OPEN 2000 20 OPEN 2300 23.5 800 Series II OPEN 2300 23.5 825 Series II OPEN 2300 23.5 835 (a) 836 CLOSED (LS) 2400 25 2000 20 OPEN 850 850 Series II OPEN 2300 23.5 OPEN 2300 23.5 855 (a) 856 CLOSED (LS) 2400 25 OPEN 2300 23.5 875 (a) 876 CLOSED (LS) 2400 25 OPEN 2400 23.6 895 (a) 900 OPEN 2000 26 OPEN 2300 25 900 Series II 905 OPEN 2300 23.5 OPEN 2300 25 935 (a) 24 CLOSED (LS) 2400 936 OPEN 2250 23.6 945 OPEN 2300 25 950 (a) OPEN 2300 25 950 Series II 955 OPEN 2250 23.6 956 CLOSED (LS) 2400 24 975 OPEN 2250 23.6 976 CLOSED (LS) 2400 24 1150 CLOSED (LS) 2500 27 1156 CLOSED (LS) 2500 27 9030 CLOSED (LS) 2400 25 9280 CLOSED (LS) 2400 25/30 9480 CLOSED (LS) 2400 25/30 9680 CLOSED (LS) 2400 25/30 9880 CLOSED (LS) 2400 25/30 (a) On 1975 or newer tractors, power steering will affect hydraulic flow. Consult your Versatile Farm Equipment dealer for special plumbing instructions. WHITE* 60 80 100 120 125 140 145 160 170 185 195 700 * 1355 * 1365 * 2-30 * 2-35 * 2-45 * 2-50 * 2-55 2-60 * 2-62 *

OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN

2200 2200 2250 2250 2250 2250 2250 2250 2500 2250 2500 3400 3400 3400 2130 2130 2275 2130 2515 2130 2275

20 20 19 22 22 22 22 22 22 22 22 5.5 5.5 5.5 5.4 5 8.5 5.5 11.9 5.5 8.5

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

1 1 3

2 2 3

32

2 2 3

2 2 2 2 2 1

2

2

2 2 2 2 1

2 2 2 2 2

2

2 2 2 1

2

2

2

2

2 1 2 2 2 2 2 1

2

1

2

2

2 2

2 2 2 2 2 2 2 2

1 1 1

2 2 2 2 2 2 2 2

2 2 1 1 1 1 1 1 1 1 1

1 1

2 2 2 2 2 2 2 2 2

2 2 2 2 2 2 2 2

3 2

3

1 1 1

2 2 2 2 2 2 2 2 2 2 2

3

1 2 2 2 2

2 1 1 1 1 1 1 1 1

2 2 2 2 2 2 2 2 2 2

2 2 2 2 1

1 1 2 2 2 2 2 2

2

CODE KEY (1) (2) (3) (LS)

1 1 2

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.

2

1 1

AG_270_Hydraulic_Guide_1206.qxp

Manufacturer and Model

12/22/06

Hydraulic System Type

9:37 AM

Page 33

Maximum Pressure (PSI)

Maximum Flow (GPM)

HM1C

HYPRO PUMP MODEL All 9302 – 9303 All 9304 – 9306 HM2C HM3C HM4C HM5C HM1C HM3C HM5C

WHITE Cont. OPEN 2415 11.9 2 3 2 2-65 2-70 * OPEN 2050 14.6 1 3 2 1 OPEN 2050 11 2 3 2 2-70 ROW CROP * (a) (d) 2-75 OPEN 2986 12 2 3 2 CLOSED 2250 18 1 2 2 2-85 * (b) 2-85 After 1979 CLOSED 2250 21 1 2 2 CLOSED 2250 21 1 2 2 2-88 2-105 * (b) CLOSED 2250 18 1 2 2 CLOSED 2250 21 1 2 2 2-105 After 1979 2-110 CLOSED 2250 21 1 2 2 CLOSED 2250 20 1 2 2 2-135 * (b) CLOSED 2250 21 1 2 2 2-135 After 1979 CLOSED 2250 20 1 2 2 2-150 * 2-160 CLOSED 2300 20 1 2 2 2300 20 1 2 2 CLOSED 2-155 * (b) 2-155 After 1979 CLOSED 2300 21 1 2 2 continuous CLOSED 2300 22 1 continuoushyd hyddraw drawmax. max. 2-180 * ( c ) 4-150 * CLOSED 2250 20 1 2 2 CLOSED 2250 20 1 2 2 4-175 * 4-180 * CLOSED 2250 20 1 2 2 CLOSED 2250 20 1 2 2 4-210 * 4-225 * CLOSED 2250 25 1 2 2 CLOSED 2250 27 1 2 2 4-270 * 6045 OPEN 2610 14.9 3 3 2 3 OPEN 2610 9.6 2 3 2 6065 14.5 1 3 2 1 OPEN 2610 6085 OPEN 2610 15.9 3 3 2 3 6105 CLOSED (LS) 2900 27 1 2 1 2 6124 2250 22 1 2 2 6125 CLOSED 6144 CLOSED (LS) 2900 27 1 2 1 2 6145 CLOSED 2250 22 1 2 2 6175 CLOSED 2500 22 1 2 1 2 6195 CLOSED 2500 22 1 2 1 2 6215 CLOSED 2500 22 1 2 1 2 6410 OPEN 3045 25.8 2 6510 OPEN 3045 25.8 2 6710 CLOSED (LS) 2900 27.7 1 2 1 2 6810 CLOSED (LS) 2900 27.7 1 2 1 2 8310 CLOSED (LS) 2900 29 1 2 1 2 8410 CLOSED (LS) 2900 29 1 2 1 2 2 1 2 CLOSED (LS) 2900 29/39 1 8510 8610 CLOSED (LS) 2900 29/39 1 2 1 2 8710 CLOSED (LS) 2900 29/39 1 2 1 2 8810 CLOSED (LS) 2900 29/39 1 2 1 2 *For use with continuous duty equipment such as hydraulic motors, auxiliary coolers are required. (a) For spraying pressures in excess of 60 PSI, use the smaller hydraulic motor. (b) After 1979, availability at remote increased to 21 GPM. (c) Do not exceed 6 GPM continual draw at remote outlet or 80 PSI deadhead pressure on pump. (d) When power steering is being used, gallonage is decreased to approximately 8 GPM, consequently so is centrifugal output.

2

2 2 2 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1

CODE KEY (1) (2) (3) (LS)

Best recommendation for high performance applications. Recommended for standard applications. Will also work. Load Sensing Hydraulic System. On all closed center, load sensing hydraulic systems, run hydraulic motor on priority circuit.