Ge Facility Signs Engineering Drawings

  • November 2019
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Ge Facility Signs Engineering Drawings as PDF for free.

More details

  • Words: 79,305
  • Pages: 203
Facility Signs Engineering Drawings

g GE Identity Program

The GE facility sign engineering drawings apply to the signs used at facilities owned or operated by the Company and its • components • subcomponents • licensed affiliates For color sketches of facility signs, see document 280, Facility Signs.

285

General Specifications

Facility Signs Engineering Drawings Contents

285.01.01

Scope of Work

285.02.01

On-Site Work Sign • Removal • Installation Foundations

285.02.02 285.02.02 285.02.03

Manufacturing Signbox & Supports Metal Painting Electrical Face • Materials • Decoration Color Alternatives Crating Inspections Storage & Supply

285.02.04 285.02.05 285.02.05 285.02.06 285.02.06 285.02.08 285.02.08 285.02.08 285.02.08

Materials

285.02.09

Maintenance General Information Routine Maintenance Call Maintenance

285.02.09 285.02.10 285.02.10 continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs Engineering Drawings Contents, continued

Primary Facility Identification Signs

Monument Signs

Pylon Signs P-20 Elevation & Installation Installation & Lighting Details Foundation Plan Foundation & Anchor Bolt Details Base Framing · Plan · Elevations · Details Pylon Fabrication · Elevations · Details Face Fabrication · Elevations · Details Sample Face Layouts P-12 Elevation & Installation Installation & Lighting Details Foundation Plan Foundation & Anchor Bolt Details Base Framing · Plan · Elevations · Details Pylon Fabrication · Elevations · Details Face Fabrication · Elevations · Details Sample Face Layouts

285.01.02

285.03.01 285.03.02 285.03.03 285.03.04 285.03.05 285.03.06 285.03.07 285.03.09 285.03.10 285.03.14 285.03.15 285.03.16 285.03.21 285.03.22 285.03.23 285.03.24 285.03.25 285.03.26 285.03.27 285.03.29 285.03.30 285.03.34 285.03.35 285.03.36

M-10 Elevation & Installation Installation & Lighting Details Foundation Plan Foundation & Anchor Bolt Details Base Framing · Plan · Elevations · Details Signbox Fabrication · Elevation · Details Face Fabrication · Elevation · Details Sample Face Layouts M-6 Elevation & Installation Installation & Lighting Details Foundation Plan Foundation & Anchor Bolt Details Base Framing · Plan · Elevations · Details Signbox Fabrication · Elevation · Details Face Fabrication · Elevation · Details Sample Face Layouts

285.05.01 285.05.02 285.05.03 285.05.04 285.05.05 285.05.06 285.05.07 285.05.09 285.05.10 285.05.14 285.05.15 285.05.16 285.05.21 285.05.22 285.05.23 285.05.24 285.05.25 285.05.26 285.05.27 285.05.29 285.05.30 285.05.33 285.05.34 285.05.35 continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs Engineering Drawings Contents, continued

Primary Facility Identification Signs, continued

Pole Signs

Ground Signs

C-12 Elevations with Overall Sign Height of · 30’0” · 35’0” · 40’0” Installation & Anchor Bolt Details Foundation Column & Column Covering Signbox Fabrication - Elevation - Details Sample Face Layouts

G-11 Elevation & Installation Installation & Lighting Details Foundation Signbox Fabrication · Elevation & Detail · Details Base Covering · Elevation & Detail · Details Face Fabrication · Elevation · Details Sample Face Layouts

C-7 Elevations with Overall Sign Height of · 20’0” · 25’0” · 30’0” Installation & Anchor Bolt Details Foundation Column & Column Covering Signbox Fabrication · Elevation · Details Face Fabrication · Elevation · Details Sample Face Layouts

285.07.01 285.07.02 285.07.03 285.07.04 285.07.05 285.07.06 285.07.07 285.07.08 285.07.10

285.07.21 285.07.22 285.07.23 285.07.24 285.07.25 285.07.26 285.07.27 285.07.28 285.07.29 285.07.30 285.07.31

G-7 Elevation & Installation Installation & Lighting Details Foundation Signbox Fabrication · Elevation & Detail · Details Base Covering · Elevation & Detail · Details Face Fabrication · Elevation · Details Sample Face Layouts G-6 Elevation & Installation Installation & Lighting Details Foundation Signbox Fabrication · Elevation & Detail · Details Base Covering · Elevation & Detail · Details Face Fabrication · Elevation · Details Sample Face Layouts

285.01.03

285.09.01 285.09.02 285.09.03 285.09.04 285.09.05 285.09.08 285.09.09 285.09.10 285.09.11 285.09.12 285.09.21 285.09.22 285.09.23 285.09.24 285.09.25 285.09.28 285.09.29 285.09.30 285.09.31 285.09.32 285.09.41 285.09.42 285.09.43 285.09.44 285.09.45 285.09.48 285.09.49 285.09.50 285.09.51 285.09.52 continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs Engineering Drawings Contents, continued

Supporting Signs

Wall Signs

Individual Elements

Cantilever Mount

Illuminated Installation Elevations: · Single-Line Layout · Stacked Layout · Optional Single-Line Layout Monogram Fabrication Elevations: · 4’0” · 6’0” · 8’0” · 10’0” Monogram Fabrication Details: · 4’0” & 6’0” · 8’0” & 10’0” Letter Fabrication Details: · 2’0”, 3’0”, & 4’6” · 4’0”, 5’0”, 6’0”, & 7’6” Laser Line Fabrication Details: · 1 1 ⁄ 2” & 2 1 ⁄ 8” · 2 7 ⁄ 8” · 3 5 ⁄ 8” Laser Line Splice Detail: All Sizes

WC-6 Elevation & Installation Installation & Fabrication Details Signbox Fabrication Face Fabrication · Elevation · Details Sample Face Layouts WC-4 Elevation & Installation Installation & Fabrication Details Signbox Fabrication Face Fabrication · Elevation · Details Sample Face Layouts

285.11.01 285.11.02 285.11.03 285.11.04 285.11.05 285.11.06 285.11.21 285.11.22 285.11.23 285.11.24 285.11.25 285.11.26

Flush Mount WF-5 Elevation & Installation Installation & Fabrication Details Signbox Fabrication Face Fabrication · Elevation · Details Sample Face Layouts WF-3 Elevation & Installation Installation & Fabrication Details Signbox Fabrication Face Fabrication · Elevation · Details Sample Face Layouts

285.13.01 285.13.02 285.13.03 285.13.04 285.13.05 285.13.06 285.13.21 285.13.22 285.13.23 285.13.24 285.13.25 285.13.26

Nonilluminated Installation Elevations: · Single-Line Layout · Stacked Layout · Optional Single-Line Layout Monogram Fabrication Elevations: · 4’0” · 6’0” · 8’0” · 10’0” Monogram Fabrication Details: · 4’0” · 6’0” · 8’0” · 10’0” Laser Line & Letter Fabrication Details: · 1 1 ⁄ 2” Laser Line & 2’0” & 3’0” Letters · 2 1 ⁄ 8” Laser Line & 3’0” & 4’6” Letters · 2 7 ⁄ 8” Laser Line & 4’0” & 6’0” Letters · 3 5 ⁄ 8” Laser Line & 5’0” & 7’6” Letters

285.01.04

285.15.01 285.15.02 285.15.03 285.15.04 285.15.05 285.15.07 285.15.08 285.15.06 285.15.09 285.15.11 285.15.12 285.15.13 285.15.14 285.15.15 285.15.16

285.15.21 285.15.22 285.15.23 285.15.24 285.15.27 285.15.30 285.15.33 285.15.25 285.15.28 285.15.31 285.15.34 285.15.26 285.15.29 285.15.32 285.15.35 continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs Engineering Drawings Contents, continued

Supporting Signs, continued

D-4 Elevation & Installation Fabrication · Elevation · Details D-6 Elevation & Installation Fabrication · Elevation · Details

GE Identity Program

Extrusions

Directional Signs D-3 Elevation & Installation Fabrication · Elevation · Details

285, Facility Signs Engineering Drawings

285.01.05

285.21.01 285.21.02 285.21.03

Details: · GE-111, GE-112, & GE-113 · GE-114, GE-115, & GE-116 · GE-117, GE-118, & GE-119

285.30.01 285.30.02 285.30.03

285.21.11 285.21.12 285.21.13 285.21.21 285.21.22 285.21.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications

Scope of Work • • • • •

The purpose of these specifications is to inform the sign contractor of the materials components finishes fabrication methods installation requirements for signs in the GE Identity Program.

GE is relying on the sign contractor’s skill integrity knowledge ability in all phases of the • design • manufacture • installation of the sign to provide the best possible identification. • • • •

The sign contractor shall examine the drawings and specifications and thoroughly investigate the conditions at the location where the sign is to be installed. The specifications and drawings are intended to describe the finished product. They are intended to be used together, and what is called for by either shall be binding as if called for by both. Questions regarding alternatives or clarification of documents should be directed to GE or its authorized representative. Wherever the term “approved equal” appears, this approval shall be in writing by GE or its authorized representative. Any substitute materials shall be equivalent to the materials outlined in the drawings, and the resulting alternative construction shall be designed to effectively support the wind load requirements for the particular installation location.

• • • • • •

285.02.01

The sign contractor shall coordinate work responsibilities to furnish all labor material equipment permits taxes insurance necessary to completely fabricate and erect the sign in accordance with the reference drawings and these specifications. The sign contractor shall secure a permit for the sign erection and furnish all engineering data and drawings necessary to obtain the permit. At locations converting existing signs to new signs, sign removal and installation shall take place concurrently. The removal operation shall not begin until the new signs are on the property or in the local installer’s inventory.

The sign contractor shall provide GE with Certificates of Insurance covering the following risks: • worker’s compensation, as required by statutes • employer’s liability insurance at the minimum rate of $1,000,000 per person • public liability and property damage liability insurance including contractual liability and property damage, with limits of not less than $1,000,000 for bodily injury and $1,000,000 for property damage • automobile liability insurance including all owned, nonowned, or hired vehicles, with limits of not less than $1,000,000 for bodily injury and $1,000,000 for property damage GE shall be named as insured on all certificates.

Insurance cancellations are not permitted without at least 30 days prior notice. The furnishing of the foregoing certificates shall not relieve the contractor from any liability or obligation for which the contractor would otherwise be responsible under this contract. continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Scope of Work, continued

On-Site Work

The sign contractor shall execute and deliver a written guarantee that, should any defect develop during the contract guarantee period due to improper • materials • workmanship • arrangements the defect shall be made good by the contractor without expense to the owner.

The installer shall provide adequate safety protection during sign removal and/or installation. Signs shall be removed in a safe and workmanlike manner. Machinery, equipment, cranes, derricks, and tools shall be of adequate size and capacity to handle the work. Work shall not be done when weather conditions are not suitable. Sign removal shall include • removing the actual signs • modifying sign foundations and buildings if required • patching architectural and/or site work surrounding the removed signs or exposed by removal of the signs to match surrounding conditions • delivering or destroying the signs as directed by GE or its authorized representative The cost of sign removal shall be included in the new sign cost unless otherwise directed.

GE Identity Program

The guarantee shall • be for a period of not less than one year from the date that the completed work is accepted by the owner • cover the cost of both labor and parts to correct defects. The guarantee shall cover labor but not parts to replace lighting tubes and lamps. Should the guarantee required under any trade section of the specifications be for a period of more or less than one year, the contractor’s guarantee shall, with respect to such trade or trades, be for such longer or shorter period.

Sign Removal The installer shall • thoroughly investigate any permit problems or new restrictive sign ordinances before removing an existing sign • report any problems to GE or its authorized representative immediately

285, Facility Signs Engineering Drawings

285.02.02

Sign Installation The installer shall • obtain all permits, inspections, and approvals required • provide for the electrical hook-up of all signs • notify the proper authority when work will be performed before arriving on the job site. If a construction manager has not been assigned to the project, the installer shall notify the facilities manager. Electrical service to the signs shall be provided by the owner or an approved subcontractor. All underground wiring shall be installed in conduit. Conduit shall be installed with as little trapping and as few bends as possible. Running thread couplings shall not be permitted.

• • • •

All materials, electrical connections, and installations shall conform to the following specifications: NEMA National Electrical Code Underwriters Laboratories, Inc. applicable federal, state, and local codes, ordinances, and regulations continued

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

On-Site Work, continued

Signs and bases shall be installed per reference drawings. The installer shall plan and execute the erection so that the close fit and neat appearance of joints and the sign as a whole are not impaired. The installer shall use special care in • unloading, handling, and erecting the sign and base components to avoid twisting or otherwise distorting or damaging the sign components • handling all sign materials to minimize damage to the shop-applied finishes • using any stage or hoisting devices to install letter signs on building walls. Any damage shall be repaired to match existing surfaces at the installer’s expense. The installer shall not erect any components damaged in transit. The installer shall • inspect all materials at the time of delivery • immediately report damages to the carrier and the sign supplier The installer shall • use only hardware as specified. Any damage or discoloration of a building or sign surface resulting from the use of unauthorized hardware shall be repaired at the installer’s expense. • test-light all signs after electrical connections have been made and report any electrical problems to the sign supplier • apply touch-up paint to all exposed sign components according to the paint manufacturer’s specifications, using the paint (or approved equal) as shown in the reference drawings. Before painting, all surfaces shall be clean and free from rust, scale, and oily or greasy residue. The contractor shall provide two sets of progress photographs at no additional cost to the owner after each of the following steps: • footing excavation • foundation pour with anchor bolts in place • completed sign installation These photographs shall show clearly all sign models and the overall area in regard to clean-up and landscaping work.

285.02.03

Foundations The requirements for earthwork necessary for the installation of ground-mounted signs include all items listed below. The installer is responsible for determining that the soil bearing capacity is adequate to satisfy the design requirements. Excavation shall include the removal of all material necessary to complete the work described in the installation drawings and specifications. The excavated material shall be placed and sloped to prevent drainage into the excavation (if the material is to be reused) or hauled away immediately and disposed of. Excavations shall be adequately protected prior to pouring concrete to minimize possible damage from the elements or construction debris and shall be barricaded to minimize hazard to external equipment, property, personnel, and facilities. When it is necessary to go deeper than the specified dimensions to meet required firm soil conditions, special provisions shall be made or an alternative location considered. All excavations for foundations, however, shall be at least to the depth of the frost line. When it is necessary to go deeper than the drawing dimensions to meet frost line requirements, the additional depth shall be provided by placing additional concrete as required. All backfilling around foundations shall be made with clean, compactible, natural earth or granular material in 6-inch layers, each layer thoroughly compacted by tamping. No backfilling shall be done until all concrete is adequately set. All finish grades shall be sloped and graded as indicated in the installation drawing. Excess material from foundation excavation shall be disposed of in a manner agreeable to the customer. continued

The installer shall clean all work areas and signs after installation is complete, removing all debris.

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

On-Site Work, continued

Except as otherwise specified, concrete shall have a 3,000 psi compressive strength at 28 days according to ACI 318 specifications. All concrete exposed to the weather shall contain 5%, ± 11 ⁄ 2%, entrained air through the use of air-entraining cement or an air-entraining admixture as specified in ACI 318. All concrete shall be vibrated or rodded to ensure complete consolidation.

Manufacturing

Signbox & Supports The sign frames and fillers are specified on reference drawings for each respective sign model. All welds shall be as specified in • AWS D1.1 (Structural Welding Code - Steel) • AWS D1.2 (Structural Welding Code - Aluminum) All removable components shall be fastened with mechanical fasteners of the positive type, such as a bolt with • a weld nut fastened to the frame • the frame tapped to accept the bolt

285.02.04

Foundations are designed for a maximum soil bearing pressure of 3,000 psf. The factor of safety against overturning is 1.5. If soil conditions appear deleterious, the bearing capacity shall be verified by exploration. For signs with a dynamic base, the base foundation shall be formed to dimensions shown in the drawings and cast monolithic with the footing. Anchor bolts shall be set with a gauged metal template furnished by the sign manufacturer.

In the assembly of components with mechanically applied finishes that will be exposed, such as fasteners and metal trim, the sign manufacturer shall grade and select parts with regard to color and finish to ensure the closest possible match and continuity of color between adjoining parts. None of these materials supplied by one manufacturer shall be intermixed with those of another manufacturer. All intermediate and finish-coat painting of subassemblies shall be performed subsequent to all fabrication and assembly.

All bolts, screws, pop-rivets, or similar items used on the frame shall be aluminum, stainless steel, or a material that will not permit galvanic action or rusting.

Work surfaces on which assemblies are to be made shall be carefully and continually maintained free from dirt, filings, or any material that might impair the quality of work.

Weep holes shall be drilled in the bottom of each signbox according to Underwriters Laboratories requirements.

All joints in exposed work shall be smoothly, solidly, and accurately fitted and rigidly secured, showing less than a 0.03-inch joint, and shall be carefully matched and aligned to produce exact continuity of line and design. Overlap joints shall be embedded in silicone caulk.

All connections shall be made as firmly as possible without stripping threads or damaging heads. Tools employed shall fit head slots precisely. All points of contact of dissimilar metals shall be separated by tape (3M #355 polyester clear or approved equal) or a prime coat of paint. All welded mitered joints shall be full penetration throughout the entire cross section.

The painted aluminum extrusions used for the signbox filler and pedestal shall have an optically flat surface quality. Sign faces shall be installed so they may be removed for replacement. The supplier shall provide adequate hardware within the sign to safely hold the hinged face sufficiently open for interior maintenance. The device shall be designed and installed so the face will not become damaged. continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Manufacturing, continued

Metal Painting All surfaces shall be cleaned and treated prior to priming. The prime coat shall be as specified by the paint manufacturer and applied as directed. All internal steel shall be painted with a coat of Sherwin-Williams Zinc Clad “5” or approved equal rust-inhibiting primer. The two-component acrylic polyurethane paints used on all exposed metal surfaces as indicated in the reference drawings shall be Matthews Acrylic Polyurethane or approved equal, applied according to the paint manufacturer’s specifications. Electrical Illumination shall be as specified in the drawings. All fabrication and installation shall comply with Underwriters Laboratories requirements and specific local code restrictions. All components shall be recognized by Underwriters Laboratories. The contractor shall manufacture and install all components in strict compliance with these requirements and restrictions. The illumination of all sign components shall be uniform in intensity over all illuminated surfaces. No noticeable hot spots or shadows shall be allowed. All signs shall be wired in accordance with the ballast and/or transformer wiring diagrams displayed on each ballast and/or transformer and shall use color-coded wire corresponding to the colors of ballast and/or transformer leads when splices are required. Individual signboxes shall be provided with make-ups on the exterior of the sign component, and all circuits shall be tagged where they are to be joined.

285.02.05

Unless specified otherwise, all fluorescent lamps shall be 800 mA, T-12, high output, rapid start, daylight white, as manufactured by GE. All sockets shall be recessed double contact, snap-in tombstone and/or butt-on type, as manufactured by Kulka Wiring Devices. All starting aids shall be supplied for each fluorescent lamp and shall be aluminum, 1 ⁄ 2 inches wide x 0.020 inches thick (alloy 5052-0), terminated at • one end with a spring connection • the other end with an “S” hook with a maximum spacing of 3 ⁄ 8 inch and a minimum spacing of 1 ⁄ 8 inch from the lamp. All ballasts shall be 120-volt “Plastic Sign Type,” for 800 mA high-output fluorescent lamps, outdoor applications, as manufactured by Jefferson, France, or approved equal. All ballasts shall be furnished with the maximum length leads allowed by Underwriters Laboratories (80 inches). All neon tubing for Laser Lines shall be 15mm Clear Red, and all neon tubing for building letters and Monograms shall be 15mm 6,500-degree White, as specified in the drawings. All transformers shall be 120 volt, 60 mA (as specified on the reference drawings), outdoor type, as manufactured by Jefferson, France, or approved equal. The maximum length of tubing operated on a single transformer shall not exceed the specific recommendations of the transformer manufacturer. All miscellaneous components, such as glass housings, electrodes, tube supports, glass tubing, and high-voltage cables, shall meet first-quality industry standards and be recognized by Underwriters Laboratories. When remote locations are required for neon transformers, the high-voltage cables shall be protected with glass-lined conduit or housings in strict accordance with all applicable local codes. This requirement specifically applies, but is not limited to, wall penetrations. The remote transformers shall be enclosed in metal encasements in compliance with local codes. continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Manufacturing, continued

Each signbox shall incorporate a separate disconnect switch, the Bell Electric Company Model 216-20-0G Weatherproof Flush Switch (Single Pole Number), covered with box number 250 (or approved equal), that shall be • flush-fit on the exterior of the signbox as located in the drawings or, in some instances, on the inside of the sign at the service door location in full view • single-, double-, or triple-pole as required by the specific sign model • painted to match the signbox When remote locations are used for the neon transformers, the disconnect switches shall be attached to the transformer housings. All exterior lighting fixtures shall be • Greenlee catalog no. CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with GE lamp no. MQI/150/T7/43 • installed according to the manufacturer’s recommendations The approximate placement of exterior lighting fixtures is shown in the drawings. Lighting tests and adjustments shall be made after the sign and base installations are complete to determine final placement. After installation, fixtures shall be adjusted to provide optimum lighting. If required, light shields shall be added to reduce objectionable lighting on surrounding surfaces. Face Materials

• • • •

There are no acceptable alternatives for the following items: face design color paint application letter style and layout Polycarbonate Faces

Sign faces shall be fabricated using Lexan® sheet products as specified in the applicable drawings: • For translucent faces, SG-100 Lexan sheet with added UV-resistant surface treatment shall be used. • Where first-surface decoration is specified, S-100 Lexan sheet may be used.

GE Identity Program

285, Facility Signs Engineering Drawings

285.02.06

Fabrication of polycarbonate faces shall follow procedures outlined in GE’s Lexan Sheet for Signs Design and Processing Guide. Hanger bars and tiebacks shall be fabricated on the flange to hold the face flat in the signbox. Flexible Faces All flexible faces shall be • 3M Panaflex Series 945 material or approved equal • installed according to 3M Company specifications All decorative films applied to a flexible face shall be • 3M Scotchcal • applied as recommended by the manufacturer Acrylic Faces All acrylic material used for Monograms and individual letters shall be • Rohm & Haas Plexiglas or approved equal • fabricated and cemented as specified in the Plexiglas Acrylic Sheet Fabrication Manual Face Decoration Polycarbonate Faces All polycarbonate opaque sign faces shall be painted on the first (exterior) surface with approved-color polycarbonate paints: • All polycarbonate shall be - thoroughly cleaned and prepared for painting per paint supplier’s specifications for the material - painted immediately after preparation • Where opaque colors are required, a coat of acrylic paint with aluminum powder added shall be applied under the color coat to ensure opacity.

• • • •

The paint and/or film colors approved for face decoration are as follows: black red to match GE color Laser Red grey to match GE colors GE 02 C and GE 05 C white to match R& H W7328 white Plexiglas (See “Color Alternatives” on page 02.08.) continued

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Manufacturing, continued

Accuracy of size and placement of graphics shall be within ± 1 ⁄ 8 -inch tolerance of the dimensions shown in the drawings. Registration shall be controlled so that color outlines are maintained and overlap within a tolerance of – 0, + 1 ⁄ 8 inch. • • • •

All faces shall be free of breaks in the paint marring, stippling, or other markings on the exterior face color, density, or translucency variations in the paint any other variations in the face that detract from the appearance of the face

The occurrence of any of the following, based on GE’s decision, will be sufficient reason for the rejection of finished faces when inspected in the plant or in the field: • painting of the face over dust, foreign particles, or other substances that may ultimately develop into pin holes or fractures in the decoration • nonuniform application of the paint that results in variable translucency or uneven light distribution • colors that do not match approved face colors under either transmitted or reflected light • marring, stippling, or any other markings on the clear glass-like quality of the exterior face • accuracy of registration beyond the specification tolerance Replacement of rejected material shall be made by the sign supplier at no cost to GE. Where 3M films are to be applied to the polycarbonate faces, • the face shall be thoroughly cleaned • the film shall be applied as specified by the 3M Company Film colors: • grey to match GE color G 05 C • red to match GE color Laser Red • black 3680-22 Scotchcal (See “Color Alternatives” on page 02.08.)

285.02.07

Acrylic Faces Acrylic faces for individual letters or Monograms shall be either • clear • white to match R& H W7328 white Letters shall have faces attached to a plastic trim cap. Letter faces shall be cleaned before applying 3M films according to 3M Company recommendations. Flexible Faces Films to be applied for face decoration shall be 3M Scotchcal or approved equal. Flexible face colors: • white 3M basic material • black 3680-22 Scotchcal • red to match GE color Laser Red (See “Color Alternatives” on page 02.08.) Centerline registration: ± 5 ⁄ 16 inch. This line shall be used to properly align and adequately tension the face within the cabinet trimwork. Image position registration: ± 1 ⁄ 4 inch from artwork. Any indicia contained in the artwork, such as trademarks, shall be within 1 ⁄ 4 inch of exact placement as specified by the artwork. Color density: approved color swatches of all colors shall be used as references for color density shift. Sufficient color swatches representing lower and upper density limits shall be generated for approval and then maintained for individual production face approvals. Image size: ± 1 ⁄ 8 inch. This reference is the actual image size and is not to be confused with the image position. The predictable dimensional instability of the material shall be computed during face decoration to maintain the ± 1 ⁄ 8 -inch tolerance on the properly tensioned and installed face. All flexible faces shall carry a five-year limited warranty against color fading and face blow-out. The warranty coverage and limitations shall be as specified in the 3M written warranty. Any seams in a flexible face shall be placed to miss any graphics wherever possible. continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Manufacturing, continued

285.02.08

Graphic Layouts

Crating

The face layouts shown in the drawings establish general guidelines only. Actual layouts with approximately the same number of characters shall be similar to those shown.

Where crating is required by contract or purchase order, signs shall be adequately blocked, braced, or suspended in a substantial shipping container furnished by the supplier.

The signature Monogram size shall remain as shown in the drawings.

If other supporting hardware is to be packaged separately, it shall be in a substantial shipping container firmly secured within the container of the sign for which it is intended.

The signature typography size may fluctuate based on face size limitations. If required, secondary messages may be placed below the Laser Line. The letter style for secondary messages shall be Univers 68 with a capital height of approximately one-half the capital height of the signature typography. Color Alternatives In lieu of the GE colors, you may use the following PANTONE®* colors, the standards for which are shown in the current edition of the PANTONE Color Formula Guide 1000. GE color

PANTONE color

For GE 02 C For GE 05 C For GE 03 C For Laser Red

use PANTONE 421C use PANTONE 422C use PANTONE 424C use PANTONE Red 032

Note: The colors shown and specified in this document are not intended to match the PANTONE Color Standards. *PANTONE® is a registered trademark of Pantone, Inc.

Inspections All signs and sign faces may be inspected by GE or its authorized representatives at any reasonable time. Such inspections may be either • at the supplier’s plant • in the field and may consist of any measurements and visual inspections deemed necessary to ensure conformance with the specifications and drawings. Any deviation from the specifications and drawings shall be sufficient reason for rejection of completed signs or faces. If repairs or replacements because of nonconformance are required prior to acceptance by GE, they shall be at the contractor’s expense. Storage & Supply Completed signs or fabricated sign parts shall be safely stored by the supplier off the ground and with proper protection. The manufacturer shall be responsible for the delivery and installation of each sign. Any damage to the signs prior to acceptance by GE shall be corrected, through repair or replacement, by the manufacturer. continued

GE Identity Program

285, Facility Signs Engineering Drawings

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

285.02.09

Materials

Unless specifically noted otherwise, the specification reference shall be the current editions or revisions of the specifications and standards listed at the right:

Steel beams Steel plate Steel sheet Steel tubing Steel pipe Aluminum sheet Aluminum plate Aluminum extrusion Steel bolts Anchor bolts Stainless steel bolts Welded wire fabric

Maintenance

General Information

For obvious economic reasons, routine maintenance and call maintenance shall be performed concurrently whenever possible.

The maintenance and service requirements for the GE sign program are divided into two categories: • routine maintenance • call maintenance Routine maintenance is work performed on a sign according to a regular (usually annual) schedule to keep the appearance and reliability of the sign in a like-new condition. • • • • •

Routine maintenance includes cleaning relamping repainting safety inspections similar maintenance All routine maintenance shall be performed in the months of May, June, July, and August in the years scheduled. Scheduling within this period shall be the prerogative of the maintenance contractor. The maintenance contractor shall coordinate routine service calls with the facilities manager before starting any work.

Call maintenance is work performed on a sign to • correct a malfunction in the signbox • ensure safe performance of the sign unit

GE Identity Program

285, Facility Signs Engineering Drawings

A.S.T.M. A36 A.S.T.M. A36 A.S.T.M. A446 A.S.T.M. A500, grade B A.S.T.M. A53 type E or S 3003-H14 6061-T6 6063-T5 A.S.T.M. A325 A.S.T.M. A36 A.S.T.M. A276 type 304 A.S.T.M. A185

Providing maintenance consists of • furnishing all materials, labor, and equipment • performing operations necessary for the maintenance of signs in accordance with this specification The maintenance contractor shall • execute all work in a first-class manner, strictly in accordance with the best practices of the trade • take all reasonable precautions to protect other property and provide the utmost public safety The maintenance contractor shall be solely responsible for the • use of proper materials • compliance with the requirements of this specification Furthermore, the maintenance contractor shall be liable for any • damage to the sign, its components, or the surrounding property • injury to persons during performance of maintenance work and shall be further liable for future damages of any type resulting from improper performance of work. continued

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Facility Signs General Specifications, continued

Maintenance, continued • •

• • •

• • -

• • • • • •

GE Identity Program

285.02.10

Routine Maintenance

Call Maintenance

When performing routine maintenance, the contractor shall inspect the total unit (signbox, column, and electrical system) from a safety standpoint and correct any unsafe condition immediately submit a complete report to GE outlining any safety defects check all bolts and screws inside the signbox and the bolts making the connection between the sign and its mounting structure and tighten them if necessary replace any damaged bolts and screws inspect the electrical system for worn or frayed wires and parts and correct any defects check for damage on faces, trim, and column test all lamps to make certain they are illuminated and remove all burned-out lamps and replace them with new fluorescent lamps of the same length, manufacturer, and color clean all exterior metal portions of the sign, including column and other structural members: Wash with soap and water. Rinse with clean water until all traces of soap are removed. Wipe dry. clean all plastic faces: Wash with mild soap and lukewarm water, using only soft cloths. Do not use strong concentrations of · alcohol · aromatic hydrocarbons · any compounds or agents that would induce plastic crazing or paint deterioration Rinse thoroughly, removing all traces of soap. Wipe dry using a clean, damp chamois cloth. wipe all fluorescent lamps with a damp cloth to remove collected dirt and dust wipe the inside of the signbox free from dirt and remove any foreign matter remove any oils, grease, or water from the interior of the signbox inspect the vents to ensure they are not clogged and clean them as required check all drain holes and unplug them as required apply touch-up paint on the signbox and column in accordance with paint specifications

Call maintenance shall be made within 72 hours of notification that service is required. The maintenance contractor should contact the GE representative.

285, Facility Signs Engineering Drawings

The maintenance contractor shall make repairs to the sign when so requested by the GE representative to ensure that all lamps and ballasts operate properly. If severe weather or significant seismic activity occurs near the sign installation (for example, wind, sand, or hail storms; tornadoes or hurricanes; floods; earthquakes), the maintenance contractor shall • make a safety inspection of the sign, checking all components for damage • if damage has made the sign or any of its components unsafe, - take temporary steps and actions to eliminate the unsafe condition - submit to GE a written report, with photographs, that details the · safety defects · recommended corrections • if damage has not made the sign or any of its components unsafe, - obtain details of the damage - report these details to GE before making permanent corrections

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from bldg.

Finished Grade

GE GE Silicones Silicones

g g

7’-6" [2286]

Plan

24

48

72

96

8’-5 15/16" [2589]

Monogram field: Black opaque, matte finish

Sign face

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/32"=1’-0"

0

Front Elevation

See Base Anchorage Detail sheet 02

See sheet 03 for foundation details

Base: GE color Laser Red or G 03 C Grey, matte finish. See sht. 05 for details

See Detail A, sheet 02

All 3 faces are fabricated identically (See sheet 14 for details)

See sheet 09 for signbox fabrication details

Base field splice (typical)

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: GE color G 02 C Grey opaque, matte finish

Monogram letters/curlicues: White translucent

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Looking Perpendicular to sign face)

Side Elevation

GE Silicones

g

7’-6" [2286]

External Lighting Fixtures: (5) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 8.1 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (3) 250 watt GE Multi-Vapor Ballasts: (1) 250W & (1) 2x250W Metal Halide Transformers: (1) 7500 Volt/60mA npf Amperage: 11.55 amps Circuits: (1) 20A/120V

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

[565]

Top hinged for service (sign also accessible from bottom) Disconnect switch located inside service access

Sign face

1’-10 7/32"

1" offset for drainage

20’-0" [6096]

Base access door

16’-11 27/32" [5178] 1 1/2" [38]

16’-7 13/32" [5065]

2" [51]

Pylon Sign, P-20 Sign Elevation & Installation Drawing

[1091]

285, Facility Signs Engineering Drawings 3’-6 31/32"

GE Identity Program

285.03.01

Pylon Sign, P-20 Sign Elevation & Installation Drawing 285.03.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

"

"[

-0 7’

4]

3 21 ]

34

21

"[

7’ -0

10’-0" [3048] min.

" -0 ] 4’ 9 21 [1

0 24 48

72

96

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/32"=1’-0"

Exterior Lighting Plan

o

90 (typ.)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

9]

21

[1

4’ -0

Direct burial light fixture w/ 150 watt metal halide bulb (4-req’d. @ front of sign)

Sign and base

(1) Direct burial light fixture w/ 150 watt metal halide bulb (optional: based on site requirements) Top of footing

0

12

Inches

3/8" dia. x 3 1/2" Hilti "Kwik-bolt" or equal (16-req’d. total)

Base foundation

Sign base

Provide 1 1/2" x 1 1/2" alum. shim plates as req’d. to bring base up level with flat section of foundation under column (approx. 3/4")

6

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1 1/2"=1’-0"

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

Base Anchorage Detail

1 1/2" [38]

6" +/- [152]

Scale: 3/4"=1’-0"

7" [178]

1’-6" [457] 7" [178]

Detail A

(2) 7/8" dia. hex. nuts & flat washers (16-req’d. total)

7/8" dia. anchor bolt (See sheet 04 for details)

10" dia. std. pipe column

3/4"+/- [19]

Pylon Sign, P-20 Installation & Lighting Details

2" [51] grout

GE Identity Program

285.03.02

Pylon Sign, P-20 Installation & Lighting Details 285.03.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front of sign

Scale: 3/16"=1’-0"

Plan

Slope down 3/4"

1’-3" 1’-3" [381] [381]

0

12

[178] [178]

7" 7"

1’-6" [457]

24

36

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

7/8" dia. anchor bolt location (8-req’d.)

Outline of flat & level concrete area @ top of foundation

Outline of sign

Outline of base

Outline of column foundation

Outline of base foundation

Base anchorage plate (typ.) 13 ’-0 4"

1/

Inches

o

1

04

4’-2 1/4" [1276] 11 11/32" [288]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

48

45

l

ca

pi

ty

Slope down 3/4"

9]

96

[3

9’-2 1/2" [2806] 4’-0" [1219]

7" 7"

4’-0" [1219]

[178] [178]

9’-2 1/2" [2806]

1’-6" [457]

18’-5" [5613]

4’-0" [1219] 4’-0" [1219]

Slope down 3/4" Slope down 3/4"

Estimated Quantities Horizontal Slab and Base Foundation: Concrete: 9.5 cu. yds.

9’-2 1/2" [2806] 9’-2 1/2" [2806]

285, Facility Signs Engineering Drawings 4’-4 3/4" [1340]

Pylon Sign, P-20 Foundation Plan

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

18’-5" [5613]

GE Identity Program

285.03.03

Pylon Sign, P-20 Foundation Plan 285.03.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-6" [457]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail

Rigid electrical conduit from bldg.

4’-0" [1219]

0 12

24

36

48

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Section 1

8’-0" [2438] (x 8’-0" [2438])

4’-0" [1219]

7" [178]

7" [178]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3/4"=1’-0"

6

12

Top of foundation

Inches

5" [128] projection Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Anchor Bolt Detail

7/8" dia. anchor bolt w/ double hex nuts & washers (8-req’d. total)

10" Dia. std. pipe column

6 x 6 - 6 / 6 welded wire fabric

Finished Grade 3/4" [19] slope 4" 8 3/4" 3’-0"

10" Dia. std. pipe column [102] [222] [914]

Base

Pylon Sign, P-20 Foundation & Anchor Bolt Details

2" [51] grout

285, Facility Signs Engineering Drawings

1’-0" [305]

GE Identity Program

285.03.04

Pylon Sign, P-20 Foundation & Anchor Bolt Details 285.03.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

-4 5’

/

13

" 32

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Front Left View on Sheet 06

[1

]

6 63

2" [51]

2 07

0

5]

[2

12

24

Vertical angle: 2 x 2 x 3/16 (typical)

1"

]

94

3 [1

36

5

3

08

48

07

08

4

45

o

4"

1/ 9]

14

[1

See Right Rear View on Sheet 06

08

4

Covering shop splice

Vertical bent plate: 2 x 2 x 3/16 (typical)

3’ -9

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

See Front Right View on Sheet 06

(similar)

9]

14

[1

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

o

4"

1/

45

3’ -9

1’-0" [305]

Base field splice

3’-3" [991]

(View Looking Perpendicular to Top)

Scale: 1/4"=1’-0"

Top View

Base field splice

5]

3 20

/3 "[ /8 13 -7 -8 1 ’ 6’ 16

[ 2"

6 50

5]

-6 4’

7/

8"

3’-3" [991]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Vertical bent plate: 3 x 3 x 3/16 (typ.)

Vertical bent plate: 3 x 3 x 3/16 (typ.)

Angle: 2 x 2 x 3/16, top only this direction

Angle: 2 x 2 x 3/16 @ top, Bent Plate: 2 x 2 x 3/16 @ bottom, this direction

Bent plate: 2 x 2 x 3/16 cont. @ bottom (typ.)

Vertical angle: 2 x 2 x 3/16 (typ.)

Covering shop splice

.250 alum. base covering

Plate: 1/4 x 4 x 6 w/ (1) 7/16" dia. hole for base anchorage (typ. 16 places)

See Left Rear View on Sheet 06

2" [51]

5’-0" [1524]

3’-3" [991]

[38]

1’-0" [305]

1 1/2"

Pylon Sign, P-20 Base Framing Plan

[305] 11’-9" [3581]

11’-9" [3581]

5’-0" [1524]

1’-0" 3’-3" [991] 3’-3" [991] 3’-3" [991]

285, Facility Signs Engineering Drawings

1’-0" [305]

GE Identity Program

285.03.05

Pylon Sign, P-20 Base Framing Plan 285.03.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Top of Base

[241]

11’-9" [3581] typical

3’-0" [914]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front Left View

[538]

1’-9 3/16" 9 15/32"

2’-6 21/32" [779]

[241]

Scale: 1/4"=1’-0"

3’-0" [914]

3’-0" [914]

0

12

48

Inches

6" [152]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

36

Bent plate: 2 x 2 x 3/16 (typ. @ bottom of base)

Front Right View

Angle: 2 x 2 x 3/16 framing (typical)

6

08

2’-0" [610]

.250 alum. covering (typ.)

2’-10 1/2" [876] 2’-10 1/2" [876]

11’-9" [3581] typical

Left Rear View

2’-10 1/2" [876] 2’-10 1/2" [876]

Base anchorage plate (typ.)

Top of Base

3’-0" [914]

3’-0" [914]

Top of Base

Southco keylatch

2’-6 21/32" 1’-9 3/16" [779] [538]

4’-3 27/32" [1317]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Right Rear View

Cont. piano hinge

7 1/2" 2’-3" [191] [686] 4’-3 27/32" [1317]

2’-0" x 2’-3" access door

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

[538]

2’-10 1/2" [876] 2’-10 1/2" [876] 3’-0" [914]

2’-6 21/32" 1’-9 3/16" [538] [779] 1’-9 3/16" 9 15/32"

3’-0" [914] 2’-10 1/2" [876] 2’-10 1/2" [876] 3’-0" [914]

285, Facility Signs Engineering Drawings

2’-6 21/32" [779]

Pylon Sign, P-20 Base Framing Elevations

Top of Base

GE Identity Program

285.03.06

Pylon Sign, P-20 Base Framing Elevations 285.03.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

2" 9 15/3 [241]

1/2

Scale: 1/2"=1’-0"

Section 2

Bent plate: 2 x 2 x 3/16

0 12

18

24

Inches

1/2" dia. bolt, nut, & washer @ field splice (typ.)

o

12

" [3

@ 1’-3

Scale: 1/2"=1’-0"

Section 3

1/2" dia. bolt, nut, & washer @ field splice (typ.)

0

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

3 spa.

57] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Signbox

Angle framing: 2 x 2 x 3/16 (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Bent plate: 3 x 3 x 3/16

Angle framing: 2 x 2 x 3/16 (typical)

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

@ 1’-5

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Bent plate: 3 x 3 x 3/16

6" [152]

5 spa.

4]

" [133

4 1/2 ] = 4’" [445

/3

3 5’-4 1

"

2 5 29/3 [150]

] 3" [76

5 7/8" [149]

Pylon Sign, P-20 Base Framing Details

3]

" [114

3’-9 81] =

68]

/8" [13

4’-5 7

1’-6" [4 " 10 1/2 [267]

36] 2" [16

1’-2" [356] 4" [102]

2" 5 27/3 [148] 067] 6

18

24

Inches

/32" [1

317] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

12

Bent plate: 2 x 2 x 3/16

56] =

3’-6" [1 1’-2" [3 spa. @ 2] 3 4" [10

285, Facility Signs Engineering Drawings

7 4’-3 2

GE Identity Program

285.03.07

Pylon Sign, P-20 Base Framing Details 285.03.07

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/2"=1’-0"

6

12

18

24

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Plate: 1/4 x 4 x 6 for base anchorage

3/16

Bent plate: 2 x 2 x 3/16

Section 4

4" [102]

Angle framing: 2 x 2 x 3/16

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

1/8

.090 x 1 1/2" long fabricated alum. keeper w/ (2) 1/4" dia. x 3/4" flat hd. mach. screws & nuts

Scale: 3"=1’-0"

0

1 1/2

1 1/8" [28]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

1 1/2

5/8" [16]

1" [25]

Section 6

0

Section 5

Angle: 1 x 1 x 1/8 x 6" long

1" [25]

GE Identity Program 3

3

Inches

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

4 1/2

.250 alum. access door

Southco low-profile, slam action keylatch (100 series) or equal

4 1/2

Angle framing: 2 x 2 x 3/16

1/4" dia. x 3/4" alum. stud, nut, & washer @ 18" c/c (typ.)

.250 alum. base covering

Pylon Sign, P-20 Base Framing Details

285.03.08

Pylon Sign, P-20 Base Framing Details 285.03.08

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

7

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/4"=1’-0"

24

36

12

14

48

12

12

Inches

9

11

1’-2 3/16"

Scale: 1/4"=1’-0"

0

24

11

36

48

Inches

[483]

18’-11" [5766] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

12

Match Line

Ladder Rung (typ.)

10

Front View, Lower Section

12

13

[360] (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Provide 1/4" dia. weep holes as req’d.

Position of this perimeter frame & supports may fluctuate due to position of Laser Line & neon (Verify w/ actual face layout)

Centerline of neon tubing & Laser Line (Exact position determined by actual face layout)

7500V/60 mA npf transformer

TS: 1 x 2 x 3/16 perimeter frame (typ. 5 places)

10" dia. std. pipe column

4" x 4" junction box & cover

3/4" dia. rigid conduit (typ.)

250W GE Multi-vapor lamp #MVR 250/C/U (3-req’d.)

TS: 1 x 2 x 3/16 brace (typ. t & b)

TS: 1 x 2 x 3/16 frame (typ.)

Extruded alum. retainer #GE-116

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

12

Front View, Upper Section

Match Line

10

8

10

12

11

3’-9" [1143]

7’-6" [2286] 3’-9" [1143]

3/4" dia. eyebolt for lifting, remove & replace w/ 3/4" dia. hex. hd. bolt after installation

18’-11" [5766]

4’-8 3/4" [1441]

4’-8 3/4" [1441]

Pylon Sign, P-20 Pylon Fabrication Drawing

4’-8 3/4" [1441] 4’-8 3/4" [1441]

285, Facility Signs Engineering Drawings

1’-7"

GE Identity Program

285.03.09

Pylon Sign, P-20 Pylon Fabrication Drawing 285.03.09

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings 1’-0" [305] R.

12

24

1/8

o

60 (typ.)

o

Inches

1 1/2 @ 3

3/16

30 (typ.)

10" dia. std. pipe column

3’-9" [1143] typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

0

o

30

7’-6" [2286] typ.

Section 7

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Detail B, sheet 13

TS: 1 x 2 x 3/16 perimeter frame

3/4" dia. x 2’-2" long steel rod ladder rung

Plate: 3/8" x 17" O.D. (10 7/8" I.D. for sleeving over column)

See Detail C, sheet 13 (3 places per face, typ.)

GE 250W Multi-vapor lamp (3-req’d.)

(1) 250W & (1) 250Wx2 Metal Halide Ballast

TS: 1 x 2 x 3/16 vertical (typ.)

TS: 1 x 2 x 3/16 frame support (typ. @ 3 intermediate frames)

3’-9" [1143] typ.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3/8"=1’-0"

12

1/8

24

Inches

1 1/2 @ 3

3/4" dia. bolt, nut, & washer (typ.)

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

3’-9" [1143] typ. See Detail D, sheet 13

7’-6" [2286] typ.

Section 8

.090 alum. neon baffle (typ.)

Angle: 2 x 2 x 3/16 neon baffle support (typ.)

C3 x 5 channel (typ.)

Plate: 3/8" x 17" O.D. (10 7/8" I.D. for sleeving over column)

.315 Lexan face (typ.)

PK housing (typ.)

1/2" dia. liquid-tight flexible conduit

7500V/60mA npf transformer

3’-9" [1143] typ.

Pylon Sign, P-20 Pylon Fabrication Details

285.03.10

Pylon Sign, P-20 Pylon Fabrication Details 285.03.10

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 1 x 2 x 3/16 vertical (typ.)

Plate: 3/8" x 17" O.D. (10 7/8" I.D. for sleeving over column)

TS: 1 x 2 x 3/16 perimeter frame (typ.)

TS: 1 x 2 x 3/16 frame support (typ. as shown t & b)

0 6

12

18

1 1/2 @ 3

24

Inches

Gusset plate: 1/4 x 3 x 6 (typ.)

10" dia. std. pipe column

3/16

Scale: 3/4"=1’-0"

6

typ.

2" [51]

12

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Section 10

Base plate: 1 x 18 x 18 w/ (8) 1" dia. holes

7" [178]

[178] [51]

1’-6" [457] 7" 2"

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3’-9" [1143] typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

Section 9

1/8

7’-6" [2286] typ.

7" 7" 2"

3’-9" [1143] typ.

Pylon Sign, P-20 Pylon Fabrication Details

2" [51] [178] [178] 1’-6" [457]

285, Facility Signs Engineering Drawings

[51]

GE Identity Program

285.03.11

Pylon Sign, P-20 Pylon Fabrication Details 285.03.11

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

0 1 1/2 3

4 1/2

3

6

Inches

1/8

Inches

1 1/2 @ 3

TS: 1 x 2 x 3/16 (typ.)

typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 13

.125 formed alum. cover w/ #10 s.s. thd. cutting screws @ 18" c/c

TS: 1 x 2 x 3/16 frame (typ.)

.315 Lexan face

Scale: 1 1/2"=1’-0"

0

Section 11

Extruded alum. retainer #GE-116 w/ #10 flat hd. csk. thd. cutting screws @ 18" c/c

10" dia. std. pipe column

Plate: 3/8" x 17" O.D. (10 7/8" I.D. for sleeving over pipe)

7/16"

1/2" dia. flex conduit

1/4

[11] [3]

Disconnect switch as req’d. mounted to tube frame

1/8

0

Scale: 3"=1’-0"

0

1 1/2

3

L: 2 x 2 x 3/16

3

Inches

.315 Lexan face

4 1/2

4 1/2

1 1/4" tube stand as req’d.

1" [25]

2 3/4" [70]

1 1/2

5/8" x 5/8" alum. hinge, cont. one side

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 14

3/16" x 3/4" cont. neoprene gasket (typ.)

7/8" film Laser Line applied to face

(1) row of 15mm clear red neon tubing

.090 formed alum. neon baffle unit riveted to angle @ 12" c/c (paint inside of baffle white)

Scale: 3"=1’-0"

Section 12

12 gage formed face support cont. w/ #10 thd. cutting screws @ 18" c/c

Extruded alum. retainer #GE-116 w/ #10 flat hd. csk. thd. cutting screws @ 18" c/c

TS: 1 x 2 x 3/16 frame (typ.)

.125 formed alum. service access w/ #10 s.s. thd. cutting screws @ 18" c/c on two sides

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Cap plate: 3/8" x 10 3/4" dia.

[5766]

Pylon Sign, P-20 Pylon Fabrication Details

2" [51]

3/4" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

18’-11" 1/8"

7/16" [11] 7/16" [11]

1/8" 1/16"

[3] [2] 18’-11" [5766] 5/8" [16] 5/8" [16]

285, Facility Signs Engineering Drawings

3 1/4" [83]

GE Identity Program

285.03.12

Pylon Sign, P-20 Pylon Fabrication Details 285.03.12

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

Scale: 3"=1’-0"

Detail B

4 7/8" [124]

0

o

6

12

TS: 1 x 2 x 3/16 frame

Extruded alum. retainer #GE-117

.315 Lexan face (typ.)

Inches

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1/2" dia. flexible liquid-tight conduit

Scale: 3"=1’-0"

Detail C

.090 x 1 1/2" long formed alum. face hold-back (typ. 3 places per face)

Lexan "T" bar

.315 Lexan face (typ.)

15mm clear red neon tubing (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

Detail D

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

C3 x 5 channel w/ 9/16 x 1 1/2 slot

1/2" dia. bolt, nut, & washer

PK housing (typ.)

45

Inches

4" [102]

4 1/2

1’-0" [305]

3

L: 2 x 2 x 3/16 w/ 7/16" x 1" slot each end

1 1/2

1 1/4" tube stand as req’d.

0

.090 formed alum. neon baffle unit

3/8" dia. bolt, nut, & washer (typ.)

L: 2 x 2 x 3/16 x 4’-6" long w/ 7/16" x 1 1/4" slot each end

Extruded Alum. retainer #GE-117

1/4" dia. hex. bolt w/ hex. nut & washer @ 18" c/c (typ.)

.315 Lexan face (typ.)

TS: 1 x 2 x 3/16 frame (typ.)

1/8

[32 ] /4" 11

[22 86 ] 7’6"

GE Identity Program 3

4 1/2

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

1/4" dia. hex. bolt w/ hex. nut & washer

TS: 1 x 2 x 3/16 frame (typ.)

Pylon Sign, P-20 Pylon Fabrication Details

285.03.13

Pylon Sign, P-20 Pylon Fabrication Details 285.03.13

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

Top of base (reference)

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish on 1st surface

Laser Line: GE color Laser Red translucent film applied to 1st surface (face area behind Laser Line remains clear)

15

16

15

17

15

18 (similar)

7 3/4" [197]

GE Silicones

g

15

0

15

18

24

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

72

96

Inches

Front Left Face

GE Silicones

[1111]

3’-7 3/4"

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Top of base (reference)

Align top of Dynamic Monogram on all 3 faces

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

48

Back Face

15

19

GE Silicones

g

g Lexan "T" bar: verify vertical location w/ sign frame & holdback (typ.)

[1111]

3’-7 3/4"

7’-3 1/2" [2223]

Pylon Sign, P-20 Face Fabrication Elevation

2’-4" [711]

7’-3 1/2" [2223]

7 3/4" [197]

7 3/4" [197]

(All 3 faces are constructed identically)

Scale: 1/8"=1’-0"

Front View

Front Right Face

.250 thick flat cut-out alum. letters painted black, matte finish, bolted to face (See Letter Attachment Detail, sheet 15) typ.

Monogram letters/curlicues: white translucent

Monogram field: black opaque, matte finish (face area behind Monogram remains clear)

.315 clear Lexan face decorated GE color G 02 C Grey opaque, matte finish on 1st surface (typ.)

15 8 13/16" [224] 2’-4" [711] 1’-2" [356]

7’-3 1/2" [2223]

5 1/4" [133] 18’-10 1/4" [5747]

1’-2" [356] 10 1/2" [267] 7/8" [22]

4’-10 9/16" [1487] 4’-10 3/4" [1492] 4’-10 3/4" [1492]

GE Identity Program

285.03.14

Pylon Sign, P-20 Face Fabrication Elevation 285.03.14

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

[3]

[13]

1 1/2

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

0

Section 18

3/4" 3/4" 3/4" [19] [19] [19]

7/8" [22]

Scale: 3"=1’-0"

3

1/8" [3]

Inches

Opaque Grey 2’-3 3/4" [705] dia. clear

Inches

1/4" [6]

2’-4" [711] Monogram

3/4" 3/4" 15/16" [19] [19] [24]

1/8" [3]

1/2" [13]

Scale: 3"=1’-0"

3

Inches

3

Inches

.315 clear Lexan face

(2) #6 x 3/4" Type BF thd. cutting screws w/ flat csk. hd.

1/8" [3]

5/16" [8]

3/16" [5]

Pylon Sign, P-20 Face Fabrication Details

5/16" [8]

0

3

Inches

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

1 1/2

0

1 1/2

3

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Letter Attachment Detail

1/4" [6]

Scale: 3"=1’-0"

Section 17

#6 x 9/16" Type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 Lexan lug, cont. (cement to face)

.315 clear Lexan face

Lexan "T" bar x 6" long (cement to face) 3-req’d. per face

1 1/2

5/16" [8]

3/16" [5]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

1 1/2

3/8" [10]

Section 19

3/8" [10]

1 1/4" [32]

Scale: 3"=1’-0"

0

Section 16

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

.315 Lexan lug, cont. (cement to face)

#6 x 9/16" Type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 clear Lexan face

Section 15 1 1/2

1/8" face face area behind Monogram

5/16" [8] 1/2"

.315 clear Lexan face decorated GE color G 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 2’-4" dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

Paint edge of alum. & acrylic black

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

1/16" [2]

1/4" [6]

3/16" [5]

1/8" [3]

285, Facility Signs Engineering Drawings 1/4" [6]

1" [25] 1 3/4" [44]

GE Identity Program

285.03.15

Pylon Sign, P-20 Face Fabrication Details 285.03.15

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 9" [229] min. (typ.)

18’-11" [5766] typical

7’-6" [2286]

Scale: 1/8"=1’-0"

24

48

72

9" [229]

7’-6" [2286]

96

Inches

Long Name

GE Electrical Distribution & Control

g

2’-4" [711]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

Medium Length Name

GE Aircraft Engines

g

2’-4" [711]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Short Name

9" [229] typ.

GE Silicones

g

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Dynamic Monogram letters/curlicues: GE color G 02 C Grey (typ.)

Dynamic Monogram field: GE color G 05 C Grey (typ.)

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Letters: black (typ.)

Monogram letters/ curlicues: white (typ.)

[22]

9" [229]

5 7/8" 1’-3 3/4" [149] typ. [400] typ.

7’-6" [2286]

[100] typ. [267] typ.

2’-4" [711] 1’-2" [356] 2’-4" 9" [711] [229] 7/8"

Monogram field: black (typ.)

9" [229]

5 1/4" [133] 10 1/2" [262]

9" 2’-4" 1’-2" 7/8" 11 13/16"

10 1/2" 3 15/16"

[229] [356] [711] [300] [22]

9" 2’-4" 1’-2"

9" [229] [229] [356] [711]

7 7/8" [200]

GE Superabrasives

g

2’-4" [711]

7’-6" [2286]

Pylon Sign, P-20 Sample Face Layouts

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

7/8" [22]

6 1/2" [165] 8 5/8" [219] 7/8" [22]

9" 3 1/4" [83]

[229] [356] [711] 1’-2" 2’-4"

GE Identity Program

285.03.16

Pylon Sign, P-20 Sample Face Layouts 285.03.16

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from bldg.

Finished Grade

See Base Anchorage Detail, sheet 22

See sheet 23 for foundation details

GE GE Silicones Silicones

g g

5’-0" [1524]

Plan

24

48

72

96

Sign face

Sign face

GE Silicones

g

5’-0" [1524]

Pylon Sign, P-12 Sign Elevation & Installation Drawing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Looking Perpendicular to sign face)

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish

Laser Line: GE color Laser Red, translucent

Graphics: Black opaque, matte finish

Face background: GE color G 02 C Grey opaque, matte finish

Monogram letters/curlicues: White translucent

External Lighting Fixtures: (5) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 8.1 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (3) 250 watt GE Multi-Vapor Ballasts: (1) 250W & (1) 2x250W Metal Halide Transformers: (1) 7500 Volt/60mA npf Amperage: 11.55 amps Circuits: (1) 20A/120V

Side Elevation

Monogram field: Black opaque, matte finish

11’-3 29/32" [3452]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

0

Front Elevation

Base: GE color Laser Red or GE 03 C Grey, matte finish. See sheet 25 for details

See Detail A, sheet 22

All 3 faces are fabricated identically (See sheet 34 for details)

See sheet 29 for signbox fabrication details

Base field splice (typical)

Top hinged for service (sign also acccessible from bottom) Disconnect switch located inside service access

1" offset for drainage

5’-7 15/16" [1726] 12’-0" [3658] 1’-3 5/16" [389]

Base access door

1 1/2" [38]

11’-0 15/16" [3377]

2" [51]

285, Facility Signs Engineering Drawings 2’-5 1/8" [740]

GE Identity Program

285.03.21

Pylon Sign, P-12 Sign Elevation & Installation Drawing 285.03.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings 2

"[

-0 7’

]

3 13 ]

33

21

"[

7’ -0

10’-0" [3048] min.

Scale: 1/8"=1’-0"

0 48

72

96

Inches

" -0 3’ 4] 1 [9

0

3

6

9

12

Inches

Scale: 1 1/2"=1’-0"

0

3

grout Inches

3/8" dia. x 3 1/2" Hilti "Kwik-bolt" or equal (12 req’d. total)

Base foundation

Sign base

Provide 1 1/2" x 1 1/2" alum. shim plates as req’d. to bring base up level with flat section of foundation under column (approx. 3/4")

1 1/2" [38]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Base Anchorage Detail

1 1/2" [38]

6" +/- [152]

Scale: 1"=1’-0"

Detail A

5" [127]

1’-2" [356] 5" [127]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Top of foundation

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

24

Exterior Lighting Plan

o

90 (typ.)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

3’ -0 14 " ]

[9

Direct burial light fixture w/ 150 watt metal halide bulb (4-req’d. @ front of sign)

Sign and base

(1) Direct burial light fixture w/ 150 watt metal halide bulb (optional based on site requirements)

(2) 3/4" dia. hex. nuts & flat washers (8 req’d. total)

3/4" dia. anchor bolt (See sheet 24 for details)

6" dia. std. pipe column

3/4" +/- [19]

Pylon Sign, P-12 Installation & Lighting Details

285.03.22

Pylon Sign, P-12 Installation & Lighting Details 285.03.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front of sign

3/4" dia. anchor bolt location

Outline of flat & level concrete area @ top of foundation

Outline of sign

Outline of base

Outline of base foundation

Base anchorage plate (typ.)

Outline of column foundation

0

12

24

5" 5" [127] [127]

1’-2" [356]

36

48

o

Inches

45

1 24

12’-8 3/4" [3879]

6’-4 3/8" [1940] 7 1/32" [179]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Slope down 3/4"

al

ic

yp

]t

43

27

"[

9’ -0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Plan

Slope down 3/4"

1’-0" 1’-0" [305] [305]

2’-9" [838]

5" 5" [127] [127]

2’-9" [838]

6’-4 3/8" [1940]

1’-2" [356]

6’-4 3/8" [1940]

12’-8 3/4" [3879]

2’-9" [838] 2’-9" [838]

Slope down 3/4" Slope down 3/4"

2’-10 1/2" [876] 3’-1 1/2" [953]

285, Facility Signs Engineering Drawings 6’-4 3/8" [1940]

GE Identity Program Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities Horizontal Slab and Base Foundation: Concrete: 4.0 cu. yds.

Pylon Sign, P-12 Foundation Plan

285.03.23

Pylon Sign, P-12 Foundation Plan 285.03.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-6" [457]

Scale: 1/4"=1’-0"

12

24

36

48

3/4" [19] slope Inches

[102] [222]

5" [127]

5" [127]

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1"=1’-0"

3

9

12

Inches

projection 4" [102]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Anchor Bolt Detail

3/4" dia. anchor bolt w/ double hex. nuts & washers (4 req’d. total)

Top of foundation

6" dia. std. pipe column

6 x 6 - 6/6 welded wire fabric

Finished Grade

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail

Rigid electrical conduit from bldg.

5’-6" [1676] (x 5’-6" [1676])

6" dia. std. pipe column

4" 8 3/4" 2’-6" [762]

Base

Pylon Sign, P-12 Foundation & Anchor Bolt Details

[38] grout 1 1/2"

285, Facility Signs Engineering Drawings

9" [229]

GE Identity Program

285.03.24

Pylon Sign, P-12 Foundation & Anchor Bolt Details 285.03.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

-5 3’

4

3/

27

’-0 11

1

6"

1 5/

[3 -5

8

5/

2]

36

1 "[

0

12

24

27

28

1"

Inches

5]

[2

2’ -6

45 o Base field splice

45

o

11" [279]

4"

1/

2’ -6 4"

1/ ]

68

[7

See Right Rear View on Sheet 26

Bent plate: 2 x 2 x 3/16 cont. @ bottom (typ.)

Covering shop splice

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

See Front Right View on Sheet 26

(similar)

4 28

]

68

[7

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(View Looking Perpendicular to Top)

Scale: 3/8"=1’-0"

3

5

4 28

Covering shop splice

.250 alum. base covering

Vertical angle: 2 x 2 x 3/16 (typical)

-1 3’

9

/1

4]

3’-0" [914]

95

[ 6"

7’-10" [2388]

Base field splice

Top View

4’

7]

37

2" [51] [38]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2

0]

06

1 "[

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Front Left View on Sheet 26

Vertical bent plate: 3 x 3 x 3/16 (typ)

Vertical bent plate: 3 x 3 x 3/16 (typ)

Angle: 2 x 2 x 3/16 @ top, Bent Plate: 2 x 2 x 3/16 @ bottom, this direction

Vertical angle: 2 x 2 x 3/16 (typ.)

Angle: 2 x 2 x 3/16, top only this direction

Plate: 1/4 x 4 x 6 w/ (1) 7/16" dia. hole for base anchorage (typ. 12 places)

See Left Rear View on Sheet 26

2" [51]

[279]

3’-0" [914]

[279] 7’-10" [2388]

11"

11" 3’-0" [914] 3’-0" [914] 11"

285, Facility Signs Engineering Drawings [279]

GE Identity Program 1 1/2"

Pylon Sign, P-12 Base Framing Plan

285.03.25

Pylon Sign, P-12 Base Framing Plan 285.03.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Top of Base

7’-10" [2388] typical

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front Left View

1’-2 1/8" 9 15/32" [359] [241]

1’-11 19/32" [599]

2’-0 1/4" [616]

1’-10 3/4" [578] 1’-10 3/4" [578]

2’-0 1/4" [616]

1’-2 1/8" [359] 1’-11 19/32" [599]

12

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

2’-0 1/4" [616]

2’-0 1/4" [616]

3" [76]

Inches

Cont. piano hinge

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

Bent plate: 2 x 2 x 3/16 framing (typ. @ bottom of base)

Front Right View 0

6 28

1’-6" [457]

.250 alum. covering (typ.)

1’-10 3/4" [578] 1’-10 3/4" [578]

7’-10" [2388] typical

Left Rear View

1’-10 3/4" [578] 1’-10 3/4" [578]

Base anchorage plate (typ.)

Top of Base

2’-0 1/4" [616]

2’-0 1/4" [616]

Top of Base

Southco keylatch

Angle: 2 x 2 x 3/16 framing (typ.)

1’-2 1/8" 9 15/32" [359] [241]

1’-9" [533] 3"

3’-1 23/32" [958] [76]

1’-11 19/32" [599]

1’-6" x 1’-9" access door

2’-0 1/4" [616] 1’-10 3/4" [578] 1’-10 3/4" [578]

285, Facility Signs Engineering Drawings

1’-2 1/8" [359]

Right Rear View

1’-11 19/32" [599]

3’-1 23/32" [958]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2’-0 1/4" [616]

Pylon Sign, P-12 Base Framing Elevations

Top of Base

GE Identity Program

285.03.26

Pylon Sign, P-12 Base Framing Elevations 285.03.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5 3/8" [137]

9

/2" [3 1’-3 1

88]

’-7" [7 4] = 2

60]

0 12

12

o

1/2" dia. bolt, nut, & washer @ field splice (typ.)

Inches

5 3/8" [137]

Signbox

4" [102]

56]

’-2" [3

Scale: 3/4"=1’-0"

Section 3

1/2" dia. bolt, nut, & washer @ field splice (typ.)

0

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Bent plate: 2 x 2 x 3/16

12

" 4 9/16 6 [11 ]

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

s@1

e 2 spac

1]

" [71 = 2’-4

9]

6" [92

Pylon Sign, P-12 Base Framing Details

56]

/1 3’-0 9

57] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Angle framing: 2 x 2 x 3/16 (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Bent plate: 3 x 3 x 3/16

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3/4"=1’-0"

Section 2

Bent plate: 2 x 2 x 3/16

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

es @

2 spac

Bent plate: 3 x 3 x 3/16

2" 9 15/3 [241]

/4" [10

[102]

2" 5 23/3 [145] 1’-2" [3

56]

58] 3 3’-1 2

3’-5 3

9 1/2" [241] 4"

1’-6" [4 6" [152]

/32" [9 1’-2" [3

285, Facility Signs Engineering Drawings

4" [102]

GE Identity Program

285.03.27

Pylon Sign, P-12 Base Framing Details 285.03.27

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Scale: 3/4"=1’-0"

Section 4 0 12

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Plate: 1/4 x 4 x 6 for base anchorage

3/16

Bent plate: 2 x 2 x 3/16

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

[102]

4"

Angle framing: 2 x 2 x 3/16

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.) 1/8

1" [25]

.090 x 1 1/2" long fabricated alum. keeper w/ (2) 1/4" dia. x 3/4" flat hd. mach. screws & nuts

Scale: 3"=1’-0"

Section 5

Angle: 1 x 1 x 1/8 x 6" long

0

[28]

1 1/8"

3

Inches

.250 alum. access door

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

Inches

Southco low-profile, slam action keylatch (100 series) or equal

3

Angle framing: 2 x 2 x 3/16

1/4" dia. x 3/4" alum. stud, nut, & washer @ 18" c/c (typ.)

.250 alum. base covering

Pylon Sign, P-12 Base Framing Details

1 1/2

5/8" [16]

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

Section 6

1"

285, Facility Signs Engineering Drawings [25]

GE Identity Program

285.03.28

Pylon Sign, P-12 Base Framing Details 285.03.28

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

2’-6" [762]

11’-3 1/2" [3442]

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3/8"=1’-0"

24

Inches

9 31

(typ.)

10 31

Scale: 3/8"=1’-0"

12

24

Inches

11’-3 1/2" [3442] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Match Line

Ladder Rung (typ.)

Front View, Lower Section

13 32

10 1/4" [260]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Provide 1/4" dia. weep holes as req’d.

Position of this perimeter frame & supports may fluctuate due to position of Laser Line & neon (Verify w/ actual face layout)

Centerline of neon tubing & laser line (Exact position determined by actual face layout)

7500V/60 mA npf transformer

TS: 1 x 2 x 3/16 perimeter frame (typ. 5 places)

6" dia. std. pipe column

4" x 4" junction box & cover

3/4" dia. rigid conduit (typ.)

250W GE Multi-vapor lamp #MVR 250/C/U (3-req’d.)

TS: 1 x 2 x 3/16 brace (typ. t & b)

TS: 1 x 2 x 3/16 frame (typ.)

Extruded alum. retainer #GE-116

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

12

12 32

14 32

2’-6" [762]

11 32

5’-0" [1524]

Front View, Upper Section

Match Line

8 30

7 30

3/4" dia. eyebolt for lifting, remove & replace w/ 3/4" dia. hex. hd. bolt after installation

2’-9 7/8" [860]

3’-0 7/8" [937]

Pylon Sign, P-12 Pylon Fabrication Drawing

2’-6 7/8" [784] 2’-9 7/8" [860]

285, Facility Signs Engineering Drawings

1’-3" [381]

GE Identity Program

285.03.29

Pylon Sign, P-12 Pylon Fabrication Drawing 285.03.29

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

TS: 1 x 2 x 3/16 frame support (typ. @ 3 intermediate frames)

285, Facility Signs Engineering Drawings 12

18

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

12

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1/2"=1’-0"

0

Scale: 1/2"=1’-0"

Section 8

0 24

Angle: 2 x 2 x 3/16 (typ.)

C3 x 5 channel (typ.)

Section 7

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Detail B, sheet 33

6

1 1/2 @ 3

.090 alum. neon baffle (typ.)

1/8

Plate: 3/8" x 1'-0" O.D. (6 11/16" I.D. for sleeving over column)

PK housing (typ.)

1/2" dia. liquid-tight flexible conduit

TS: 1 x 2 x 3/16 perimeter frame

o

60 (typ.)

3/16

30o (typ.)

7500V/60mA npf transformer

24

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

18

1 1/2 @ 3 3/4" dia. bolt, nut, & washer (typ.)

1/8

2’-6" [762] typ. See Detail D sheet 33

5’-0" [1524] typ. 2’-6" [762] typ.

.315 Lexan face (typ.)

9" [229] R.

3/4" dia. x 1’-9" long steel rod ladder rung

2’-6" [762] typ.

Plate: 3/8" x 1’-0" O.D. (6 11/16" I.D. for sleeving over column)

6" dia. std. pipe column

See Detail C, sheet 33 (3 places per face, typ.)

GE250W Multi-vapor lamp (3-req’d.)

(1) 250W & (1) 250Wx2 Metal Halide Ballast

TS: 1 x 2 x 3/16 vertical (typ.)

5’-0" [1524] typ. 2’-6" [762] typ.

Pylon Sign, P-12 Pylon Fabrication Details

285.03.30

Pylon Sign, P-12 Pylon Fabrication Details 285.03.30

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/2"=1’-0"

0

Section 9

TS: 1 x 2 x 3/16 vertical (typ.)

Plate: 3/8" x 1’-0" O.D. (6 11/16" I.D. for sleeving over column)

TS: 1 x 2 x 3/16 perimeter frame (typ.)

TS: 1 x 2 x 3/16 frame support (typ. as shown t & b)

12

18

24

1 1/2 @ 3

Inches

1/8

2’-6" [762] typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

5’-0" [1524] typ. 2’-6" [762] typ.

Scale: 1"=1’-0"

0

Section 10 3

10" [254]

6

1’-2" [356]

9

12

Inches

typ.

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2" [51]

3/16

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6" dia. std. pipe column

Gusset plate: 1/4 x 3 1/2 x 6 (typ.)

Base plate: 5/8 x 14 x 14 w/ (4) 7/8" dia. holes

2" [51]

Pylon Sign, P-12 Pylon Fabrication Details

10" [254]

2" [51] 1’-2" [356]

285, Facility Signs Engineering Drawings

2" [51]

GE Identity Program

285.03.31

Pylon Sign, P-12 Pylon Fabrication Details 285.03.31

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Scale: 1 1/2"=1’-0"

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

0 1 1/2

3

3

4 1/2

6

1 1/2 @ 3

Inches

1/8

TS: 1 x 2 x 3/16 (typ.)

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 13

.125 formed alum. cover w/ #10 s.s. thd. cutting screws @ 18" c/c

TS: 1 x 2 x 3/16 frame (typ.)

.315 Lexan face

0

Section 11

Extruded alum. retainer #GE-116 w/ #10 flat hd. csk. thd. cutting screws @ 18" c/c

6" dia. std. pipe column

Plate: 3/8" x 1’-0" O.D. (6 11/16" I.D. for sleeving over pipe)

1/2" dia. flex conduit

5/16" 1/8"

1/4

[8] [3]

Disconnect switch as req’d. mounted to tube frame

typ.

11’-3 1/2" [3442]

1/8

Cap plate: 3/8" x 6 5/8" dia.

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

0

1 1/2

3

Inches

Angle: 2 x 2 x 3/16

4 1/2

.315 Lexan face

3

4 1/2

1 1/4" tube stand as req’d.

1" [25]

2 3/4" [70]

1 1/2

5/8" x 5/8" alum. hinge, cont. one side

Pylon Sign, P-12 Pylon Fabrication Details

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 14

3/16" x 3/4" cont. neoprene gasket (typ.)

9/16" film Laser Line applied to face

(1) row of 15mm clear red neon tubing

.090 formed alum. neon baffle unit riveted to angle @ 12" c/c (paint inside of baffle white)

Scale: 3"=1’-0"

Section 12

12 gage formed face support cont. w/ #10 thd. cutting screws @ 18" c/c

Extruded alum. retainer #GE-116 w/ #10 flat hd. csk. thd. cutting screws @ 18" c/c

TS: 1 x 2 x 3/16 frame (typ.)

.125 formed alum. service access w/ #10 s.s. thd. cutting screws @ 18" c/c on two sides

9/32"

3/4" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

[7] [7]

9/32"

1/8" 1/16"

[3] [2] 11’-3 1/2" [3442] 5/8" [16] 2" [51]

5/8" [16]

285, Facility Signs Engineering Drawings

3 1/4" [83]

GE Identity Program

285.03.32

Pylon Sign, P-12 Pylon Fabrication Details 285.03.32

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

Scale: 3"=1’-0"

Detail B

4 7/8" [124]

0

o

6

12

TS: 1 x 2 x 3/16 frame

Extruded alum. retainer #GE-117

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 Lexan face (typ.)

Inches

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1/2" dia. flexible liquid-tight conduit

Scale: 3"=1’-0"

Detail C

.090 x 1 1/2" long formed alum. face hold-back (typ. 3 places per face)

Lexan "T" bar

.315 Lexan face (typ.)

15mm clear red neon tubing (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

Detail D

C3 x 5 channel w/ 9/16" x 1 1/2" slot

1/2" dia. bolt, nut, & washer

PK housing (typ.)

45

Inches

4" [102]

4 1/2

1’-0" [305]

3

Angle: 2 x 2 x 3/16 w/ 7/16" x 1" slot each end

1 1/2

1 1/4" tube stand as req’d.

0

.090 formed alum. neon baffle unit

3/8" dia. bolt, nut, & washer (typ.)

Angle: 2 x 2 x 3/16 x 4’-6" lg. w/ 7/16" x 1 1/4" slot each end

Extruded Alum. retainer #GE-117

1/4" dia. hex. bolt w/ hex. nut & washer @ 18" c/c (typ.)

.315 Lexan face (typ.)

TS: 1 x 2 x 3/16 frame (typ.)

1/8

[32 ] /4" 11

[15 24 ] 5’0"

GE Identity Program 3

4 1/2

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

1/4" dia. hex. bolt w/ hex. nut & washer

TS: 1 x 2 x 3/16 frame (typ.)

Pylon Sign, P-12 Pylon Fabrication Details

285.03.33

Pylon Sign, P-12 Pylon Fabrication Details 285.03.33

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

16 35

17 35

18 35

0

18 35

12

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

4’-9 1/2" [1461]

36

48

Inches

Back Face

Front Left Face

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Top of base (reference)

Align top of Dynamic Monogram on all 3 faces

2’-4 3/4" [730]

GE Silicones

g

2’-4 3/4" [730]

4’-9 1/2" [1461]

Pylon Sign, P-12 Face Fabrication Elevation

Lexan "T" bar: verify vertical location w/ sign frame & holdback (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

[121]

19 35

GE Silicones

g

1’-6 1/2" [470]

4 3/4"

4 3/4" [121]

(All 3 faces are constructed identically)

Scale: 1/4"=1’-0"

Front View

(similar)

4 3/4" [121]

GE Silicones

g

15 35

Front Right Face

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Dynamic Monogram letters/curlicues are GE color G 02 C Grey opaque, matte finish

Top of base (reference)

Dynamic Monogram field is GE color GE 05 C Grey opaque, matte finish on 1st surface

Laser Line: Red translucent film to match GE color Laser Red applied to 1st surface (face area behind Laser Line remains clear)

.250 thick flat cut-out alum. letters painted black, matte finish bolted to face (See Letter Attachment Detail, sheet 35) typ.

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish (face area behind Monogram remains clear)

.315 clear lexan face decorated GE color GE 02 C Grey opaque, matte finish on 1st surface (typ.)

5 13/16" [148] 1’-6 1/2" [470] 9 1/4" [235]

4’-9 1/2" [1461]

3 1/2" [89] 11’-2 7/8" [3426]

9 1/4" [235] 7" [178] 9/16" [14]

2’-10" [864] 3’-1" [940] 2’-7" [787]

GE Identity Program

285.03.34

Pylon Sign, P-12 Face Fabrication Elevation 285.03.34

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1 1/2

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

0

Section 18

3/4" 3/4" 3/4" [19] [19] [19]

7/8" [22]

Scale: 3"=1’-0"

3

1/8" [3]

1/4" [6]

1’-6 1/2" [470] Monogram

3/4" 3/4" 15/16" [19] [19] [24]

1/8" [3]

1/2" [13]

Scale: 3"=1’-0"

3

Inches

3

Inches

.315 clear Lexan face

(2)#6 x 3/4" Type BF thd. cutting screws w/ flat csk. hd.

1/8" [3]

5/16" [8]

3/16" [5]

Pylon Sign, P-12 Face Fabrication Details

5/16" [8]

0

3

Inches

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

1 1/2

0

1 1/2

3

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Letter Attachment Detail

1/4" [6]

Scale: 3"=1’-0"

Section 17

#6 x 9/16" Type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 Lexan lug, cont. (cement to face)

.315 clear Lexan face

Lexan "T" bar x 6" long (cement to face) 3-req’d. per face

1 1/2

5/16" [8]

3/16" [5]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

1 1/2

3/8" [10]

Section 19

3/8" [10]

1 1/4" [32]

Scale: 3"=1’-0"

0

Section 16

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Inches

.315 Lexan lug, cont. (cement to face)

3

face area behind Monogram

Inches

#6 x 9/16" Type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 clear Lexan face

1 1/2

[3]

[13]

Section 15

.315 clear Lexan face decorated GE color G 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 1’-6 1/2" dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

Paint edge of alum. & acrylic black

1/8"

5/16" [8] 1/2"

Opaque Grey face 1’-6 1/4" [464] dia. clear

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

1/16" [2]

1/4" [6]

3/16" [5]

1/8" [3]

285, Facility Signs Engineering Drawings 1/4" [6]

1" [25] 1 3/4" [44]

GE Identity Program

285.03.35

Pylon Sign, P-12 Face Fabrication Details 285.03.35

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

6" [152]

Scale: 3/16"=1’-0"

0

6" [152]

24

36

48

Inches

Long Name

GE Electrical Distribution & Control

g

[470]

1’-6 1/2"

5’-0" [1524]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

Face Layouts

Medium Length Name

GE Aircraft Engines

g

[470]

1’-6 1/2"

5’-0" [1524]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Short Name

GE Silicones

g

[470]

1’-6 1/2"

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Dynamic Monogram letters/curlicues: GE color G 02 C Grey (typ.)

Dynamic Monogram field: GE color G 05 C Grey (typ.)

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Letters: Black (typ.)

Monogram letters/ curlicues: White (typ.)

Monogram field: Black (typ.)

6" [152]

7" [178]

5’-0" [1524]

6" [152] [470] 3 1/2" [89] 11’-3" [3429] typical

9 1/4" [235] 1’-6 1/2" 9/16" [14]

[470]

6" [152] 1’-6 1/2" 8" [203] 9/16" [14]

7" [178] typ. 2 5/8" [67] typ.

[470]

6" [152] 1’-6 1/2" 5 1/4" [133] 9/16" [14]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

6" [152] min. (typ.)

GE Superabrasives

g

[470]

1’-6 1/2"

6" [152] (typ.)

6" [152]

5’-0" [1524]

Pylon Sign, P-12 Sample Face Layouts

4 5/16" [110] 5 3/4" [146] 9/16" [14]

[470]

6" [152] 1’-6 1/2" 2 1/8" [54]

285, Facility Signs Engineering Drawings

9 1/4" [235]

GE Identity Program

285.03.36

Pylon Sign, P-12 Sample Face Layouts 285.03.36

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

18’-9" [5715]

22’-6 1/2" [6871]

Plan

15’-11" [4851]

24

48

72

96

Inches

See sheet 14 for face fab. details

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

See Detail A, sheet 02

See Base Anchorage Detail sheet 02

1’-2 1/4" [362]

[1348] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side Elevation

Disconnect switch

Back is hinged for service (GE color G 02 C Grey)

Filler is GE color G 02 C Grey matte finish

External Lighting Fixtures: (2) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 3.24 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (5) GE F48T12 DL/HO Ballasts: (1) 2-Lamp & (1) 3-Lamp Transformers: (1) 7500 Volt/60mA npf Amperage: 7.5 amps Circuits: (1) 20A/120V

Base: GE color Laser Red or G 03 C Grey, matte finish. See sheet 05 for details

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/32"=1’-0"

0

Front Elevation

10’-9" [3277]

c

g GE Silicones

1’-2 1/4" [362] 1’-10 3/4" [578]

Sign face

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish

1’-10 3/4" [578]

6’-7 1/2" [2019]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from bldg.

See sheet 03 for foundation details

Finished Grade

Laser Line: GE color Laser Red translucent

Face background: GE color G 02 C Grey opaque, matte finish

Graphics: Black opaque, matte finish

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 09 for signbox fabrication details

Base field splice (typical)

[765]

9’-4 23/32" [2863] 11’-8 25/32" [3576] 2’-6 1/8"

11’-8 25/32" [3576] 9’-4 23/32" [2863]

1" offset for drainage

7’-6" [2286]

Base access door

2’-0 7/16" [621]

6’-7 1/2" [2019]

2’-1 17/32" [648] 8 3/4" [222]

15’-11" [4851]

1" [25]

285, Facility Signs Engineering Drawings

4’-5 1/16"

GE Identity Program 9’-7 17/32" [2934]

Monument Sign, M-10 Sign Elevation & Installation Drawing

285.05.01

Monument Sign, M-10 Sign Elevation & Installation Drawing 285.05.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 10’-9" [3277] (+/- 1’-0")

5’-0" [1524]

4’-0" [1219]

Scale: 3/32"=1’-0"

24

48

72

96

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Exterior Lighting Plan

4’-0" [1219]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Direct burial light fixture w/ 150 watt metal halide bulb (2-req’d.)

Sign base

Signface

6" +/ [152]

3

1 1/2" [38]

0

6

4" [102]

9

3" [76]

12

Inches

Scale: 1 1/2"=1’-0"

0

3

Inches

Base foundation

3/8" dia. x 3 1/2" Hilti "Kwik-bolt" or equal (18 req’d. total)

Provide 1 1/2" x 1 1/2" alum. shim plates as req’d. to bring base up level with flat section of foundation under column (approx. 3/4")

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Base Anchorage Detail

Scale: 1"=1’-0"

Detail A

3" [76]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Sign base

Top of foundation

(2) 1" dia. hex. nuts & flat washers (8-req’d. per column)

1" dia. anchor bolt (See sheet 04 for details)

10" [254]

3/4" +/- [19]

TS: 5 x 5 x 3/8 column

Monument Sign, M-10 Installation & Lighting Details

2" [51] grout

GE Identity Program

285.05.02

Monument Sign, M-10 Installation & Lighting Details 285.05.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

1

2’-

6"

/1 57 ] 8 [74 pe 3/4 0

0"

15

" ’-0

[45

72

]

9 [60

12

36

48

Inches

30

o

Outline of base

Outline of base foundation

Base anchorage plate (typ.)

1" dia. anchor bolt location

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

Front of sign

’20

"

Scale: 3/16"=1’-0"

Plan

slo 6]

2" [51] typ.

/4"

e3

p slo

1’-0" [305]

6’-6 3/4" [2000]

5]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

/4"

e3

p slo

/4"

04

2’-0" [610]

e3

[30

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Outline of sign

Outline of flat & level concrete area @ top of foundation

Outline of column foundation

2’-0" [610]

4’-0" [1219]

12’-9" [3886]

10’-9" [3277]

4 1/2" [114] typ.

23’-1 1/8" [7039]

4’-3" [1295]

5’-9 3/8" [1762]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities Horizontal Slab and Base Foundation: Concrete: 9.2 cu. yds.

8’-6" [2591]

GE Identity Program 0" 1’-

4’-3" [1295]

p slo

1’-3" 1’-3" [381] [381]

Monument Sign, M-10 Foundation Plan

285.05.03

Monument Sign, M-10 Foundation Plan 285.05.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1’-6" [457]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electical conduit from bldg.

Base 4 3/4" [121]

0 12

24 36

Inches

3’-0" [914] 4" 8 3/4" [102] [222]

0

3

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1"=1’-0"

6

12

Inches

TS: 5 x 5 x 3/8 column

projection grout

2" [51]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

9

Anchor Bolt Detail

1" dia. anchor bolt w/ double hex. nuts & washers (8-req’d. total)

See Anchor Bolt Detail

3/4" [19] slope

TS: 5 x 5 x 3/8 column (typ.) Finished Grade

Top of foundation

48

6 x 6 - 6/6 welded wire fabric

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

Section 1

4’-0" [1219]

10’-9" [3277]

Monument Sign, M-10 Foundation & Anchor Bolt Details

4" [102] 1’-0" [305]

GE Identity Program

285.05.04

Monument Sign, M-10 Foundation & Anchor Bolt Details 285.05.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5’-0" [1524]

13’-3" [4039]

3

07

Angle: 2 x 2 x 3/16, top only this direction

1’10 [57 5/8" 5]

2" [51]

22 ’-6

]

13

[14

18 1]

0

12

24

g)

36

nin

]

13 pe

(O

[14

48

9"

Inches

4’-

08

4

]

48

[14

4’-0" [1219]

10 5 [57 /8" 5]

1’-

6"

2]

[15

.

Angle: 2 x 2 x 3/16 (typ.)

Base field splice

1/2" dia. bolt, nut & lockwashers (typ.)

Angle: 2 x 2 x 3/16 @ top, Bent plate: 2 x 2 x 3/16 @ bottom, this direction

Alum. angle: 1 x 1 x 1/8 x 3"lg. splice leveler @ 24" c/c (typ.)

Covering shop splice (typ.)

Vert. angle: 2 x 2 x 3/16 (typ.)

.250 Aluminum covering

See Right Rear View on Sheet 06

See Front Right View on Sheet 06

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Angle: 2 x 2 x 3/16 @ bottom (cont.)

Bent plate: 2 x 2 x 3/16 (cont.)

typ

o

60

1’-2 1/4" [362]

2’-2 1/4" [667] 4’-0" [1219]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(View Looking Perpendicular to Top)

Scale: 1/4"=1’-0"

1]

72

" [5

75

4’1/4

/8"

4’-0" [1219]

’-9

87

" [6

1/2

6 08

Top View

/8"

75

4’-

5

4’-0" [1219]

2 to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2" [51]

]

48

[14

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Plate: 1/4 x 4 x 6 w/ (1) 7/16" dia. hole for base anchorage (typ. 18 places)

9"

4’-

Covering shop splice (typ.)

Vert. angle: 2 x 2 x 3/16 (typ.)

Base field splice

See Front Left View on Sheet 06

5’-0" [1524]

1’-2 1/4" [362]

07

See Left Rear View on Sheet 06

1 1/2" [38]

08

18’-4 1/2" [5601]

1" [25 ]

7 Spaces @ 2’-0" [610] = 14’-0" [4267]

1’37 [40 /8" 3]

5’-0" [1524] 5’-0" [1524]

2’-2 1/4" [667]

1’-1 1/2" 3’-8" [1118] 3’-8" [1118] 3’-8" [1118]

285, Facility Signs Engineering Drawings 55 /3 [13 2" 1]

[343] [343]

GE Identity Program 1’-1 1/2"

Monument Sign, M-10 Base Framing Plan

285.05.05

Monument Sign, M-10 Base Framing Plan 285.05.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

9 15/32" [241]

Top of Base

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front Left View

2’-5 1/4" [743]

3’-2 23/32" [983]

3’-2 23/32" 1’-11 7/16" [983] [595] 9 15/32" [241]

Top of Base

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

24

2’-2 1/4" [667]

2’-2 1/4" [667]

1’-9" [533]

3 1/4" [83]

36

48

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

7 08

Cont. piano hinge

2’-0" [610] 2’-0" [610]

Bent plate: 2 x 2 x 3/16 framing (typ. @ bottom of base)

Front Right View

Angle: 2 x 2 x 3/16 framing (typ.)

.250 alum. covering (typ.)

7 spaces @ 2’-0" [610] = 14’-0" [4267]

18’-4 1/2" [5601]

Left Rear View

7 spaces @ 2’-0" [610] = 14’-0" [4267]

Base anchorage plate (typ.)

2’-2 1/4" [667]

2’-2 1/4" [667]

Top of Base

Southco keylatch

3" [76] 2’-8 29/32" 2’-5 1/4" [743] [836]

1’-2" 1’-2" [356] [356]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Right Rear View

1/2" dia. bolt, nut, & lockwasher @ field splice (typ.)

5’-2 5/32" [1579]

Monument Sign, M-10 Base Framing Elevations

1’-2 1/2" [368]

1’-9" x 2’-0" access door

5’-2 5/32" [1579]

2’-8 29/32" [836]

1/2" dia. bolt, nut, & lockwasher @ field splice (typ.)

2’-0" 1’-0" 2’-1 3/4" [610] [305] [654]

2’-0" 2’-0" [610] [610] 13’-3" [4039]

2’-0" [610]

2’-1 1/4" [641]

2’-0 1/4" [616] 2’-0" [610] 2’-0" [610] 2’-0" [610] 2’-0" [610] 2’-0 1/4" [616]

285, Facility Signs Engineering Drawings 1’-11 7/16" [595]

Top of Base

GE Identity Program

285.05.06

Monument Sign, M-10 Base Framing Elevations 285.05.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

o

Scale: 3/4"=1’-0"

Section 2

12

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Angle: 2 x 2 x 3/16 cont.

Angle: 2 x 2 x 3/16 vert.

Bent plate: 2 x 2 x 3/16

1’-3 7

0

3] /8" [40

12

Inches

Scale: 3/4"=1’-0"

Section 3

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Bent plate: 2 x 2 x 3/16 cont.

Angle: 2 x 2 x 3/16 brace w/ 9/16" x 1" slot & (2) 1/2" dia. bolts, nuts & lockwashers each end (typ. 3 places)

Angle: 2 x 2 x 3/16 framing (typ.)

3" [76] 1’-2" [356] +/-

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Signbox

9]

1’-2" [356] +/-

285, Facility Signs Engineering Drawings 9" [22

3" [76]

GE Identity Program 6

12

Inches

1/2" dia. bolt, nut, lockwasher @ field splice (typ.)

Bent plate: 3 x 3 x 3/16 corner vertical

Angle: 2 x 2 x 3/16 framing (typ.)

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

6" [152]

Monument Sign, M-10 Base Framing Details

285.05.07

Monument Sign, M-10 Base Framing Details 285.05.07

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

Scale: 3/4"=1’-0"

Section 4

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 6

(2) Alum. angle: 1 x 1 x 1/8 x 3" lg. splice levelers

0

1 1/2

Inches

3

Inches

(1) 3/16" dia. bolt, nut, & lockwasher

typ. ea. end

Center line base covering shop splice

12

Bent plate: 2 x 2 x 3/16

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

6

Plate: 1/4 x 4 x 6 for base anchorage

3/16

.250 alum. base covering

[102]

4"

Angle framing: 2 x 2 x 3/16

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

1/8

1" [25]

.090 x 1 1/2" long fabricated alum. keeper w/ (2) 1/4" dia. x 3/4" flat hd. mach. screws & nuts

Scale: 3"=1’-0"

Section 5

Angle: 1 x 1 x 1/8 x 6" long

0

[28]

1 1/8"

3

Inches

.250 alum. access door

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

Inches

Southco low-profile, slam action keylatch (100 series) or equal

3

Angle framing: 2 x 2 x 3/16

1/4" dia. x 3/4" alum. stud, nut, & washer @ 18" c/c (typ.)

.250 alum. base covering

1 1/2

5/8" [16]

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

Section 7

1"

GE Identity Program [25]

Monument Sign, M-10 Base Framing Details

285.05.08

Monument Sign, M-10 Base Framing Details 285.05.08

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3’-4" [1016]

13

12

Scale: 1/4"=1’-0"

0

Front View

TS: 5 x 5 x 3/8 column

12

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 1 x 10 x 13 w/(4) 1 1/4" dia. holes

Rigid electrical conduit from building

11

9

13

15

Extruded alum. T-bar #GE-113

(1) 7500 volt/ 60 mA npf transformer in alum. trans. box

36

48

Inches

12

11

Extruded alum. filler #GE-111

1/2" dia. eyebolt for lifting (typ.) Replace w/ 1/2" dia. rd. hd. mach. screw after installation

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

C3 x 5 for mounting transformer box

Bent plate: 1 1/4 x 2 x 3/16 x 3" lg. (typ.)

Alum. angle: 2 x 2 x 3/16 corner reinforcing (typ. ea. corner)

4’-0" [1219]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

13

13

9’-4 1/2" [2858]

.125 fabricated alum. support bracket (typ. each end)

13

15

13

(1) 2-lamp & (1) 3-lamp ballast in alum. ballast box & cover (f.s. of column)

14

8

10’-9" [3277]

10

4’-8 1/4" [1429]

9’-4 1/2" [2858]

3’-10 1/4" [1175]

Disconnect switch

12

10

6" [152]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

15 mm clear red neon tubing (Verify that neon will illuminate entire length of Laser Line) Neon tube length & position varies based on face layout

1/2" dia. flex liquid-tight conduit typ.

(5) GE F48T12 DL/HO lamps

6 1/4" [159]

4" [102]

4" [102]

1’-4 1/4" [413]

4’-0" [1219]

3’-3" [991]

18’-9" [5715]

7’-7" [2311]

Angle: 1 1/2 x 1 1/2 x 3/16 (typical top & bottom)

8" [203]

Monument Sign, M-10 Signbox Fabrication Drawing

6’-8" [2032] (hinged back for service)

11" [279]

285, Facility Signs Engineering Drawings 2’-6 17/32" [775]

GE Identity Program

285.05.09

Monument Sign, M-10 Signbox Fabrication Drawing 285.05.09

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1 1/2"=1’-0"

Section 8

8" [203]

0

3" [76]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.090 Alum. flourescent lighting baffle unit (Paint inside white)

3/16" x 3/4" cont. neoprene gasket (typ.)

Angle: 1 1/2 x 1 1/2 x 3/16 lighting baffle suport

#10 flat hd. CSK self-tapping screws @ 18" c/c (typ.)

Extruded alum. retainer #GE-112

1/2" dia. rd. hd. mach. screw, nut & lockwasher (4-req’d. per column) gage = 7"

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. w/(1) 3/8" dia. hex. bolt, nut & lockwasher

.125 Alum. back

Cap plate: 1/4 x 5 x 10

3/16" x 1/2" neoprene gasket, cont.

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

.090 x 3/4 x 3/4 x 3" lg. alum. hinge (@ 3’-0" c/c) Rivet to filler, weld to retainer

1/2" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3

3/16

typ.

6 1/4" [159]

1’-2 1/4" [362]

Monument Sign, M-10 Signbox Fabrication Details

285.05.10

Monument Sign, M-10 Signbox Fabrication Details 285.05.10

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1’-4 1/4" [413] varies

3 1/4" [83]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1" [25]

Scale: 1 1/2"=1’-0"

Section 9

2 3/4" [70]

0

3

3/16

6

Inches

Monument Sign, M-10 Signbox Fabrication Details

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Bell flush disconnect switch #216-20-OG w/ Bell box #250

.125 Alum. formed backing bar (Weld lower section to back) cont.

3/16" x 1" neoprene gasket cont.

#10 flat hd. CSK self -tapping screw & tinnerman "J" nut @ 18" c/c

1/2" dia. flex. liquid tight conduit

PK housing

.125 Alum. back

Extruded alum. filler #GE-111

6 3/4" [171] min.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

7 1/2" [190]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 1 x 10 x 13

TS: 5 x 5 x 3/8 column

Rigid electrical conduit

5/8" dia. hex. hd. bolt, nut & lockwasher (4) req’d. per column Gage = 7"

Plate: 1/2 x 9 1/2 x 9 1/2

Provide 1/4" dia. weep holes as req’d.

.315 Lexan face: See sheet 14 for details

Angle: 1 1/2 x 1 1/2 x 3/16 x 8" lg. w/ (1) 3/8" dia. hex. bolt, nut & lockwasher in 7/16" x 3/4" slot (typ. n.s. & f.s.)

1 1/4" tube stand as req’d.

(1) row of 15mm clear red neon tubing 5/8" [16] 2" [51] 5/8" [16]

.090 Alum. neon baffle unit w/ end closures (Pop rivet to 1 1/2 x 1 1/2 x 3/16 x 8’-0" long back-up angle) Paint inside baffle white

11" [279]

GE Identity Program

285.05.11

Monument Sign, M-10 Signbox Fabrication Details 285.05.11

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5 1/4" [133]

3’-10 1/4" [1175]

4’-2 1/4" [1276]

Scale: 1 1/2"=1’-0"

0 3

6

9" [229]

0

3

6

4" [102]

9

3" [76]

12

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1"=1’-0"

Section 11

TS: 5 x 5 x 3/8 column

Base plate: 1 x 10 x 13 w/ (4) 1 1/4" dia. holes

3" [76]

10" [254]

3/16" x 3/4" neoprene gasket, cont. all around

1/2" dia. x 1 1/2 short nipple w/ locknuts

1/2" dia. flex. conduit

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to column) typ. @ t & b of lighting baffle

(1) 2-lamp & (1) 3-lamp ballast in .125 x 4 x 3 alum. ballast box & cover

.125 Alum. back

1 1/4 x 2 alum. raceway & cover Kulka socket #582-G

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

.125 x 2 cont. alum. back-up bar (Weld to non-hinged side of back)

.090 alum. light baffle unit

Kulka socket #583-G

(5) GE F48T12 DL/HO lamps

.125 Alum. back w/ #10 s.s. sht. metal screws 12" c/c (hinged for service)

Section 10

2" [51]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.315 Lexan face

4" [102]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Angle: 1 1/2 x 1 1/2 x 3/16 x 4’-4" lg. w/ (2) 3/8" dia. hex. bolts, nuts & lockwashers (Pop rivet to baffle unit) typ. t & b 1 1/4" [32]

Alum. angle: 3 x 3 x 3/16 x 3" lg. (Weld to filler) typ. @ t & b of lighting baffle

Extruded Alum. filler #GE-111

.090 x 3/4 x 3/4 x 3" lg. alum. hinge @ 1’-6" c/c (Weld to back rivet to side)

4" [102]

2" [51] 9" [229]

285, Facility Signs Engineering Drawings

1’-1" [330]

GE Identity Program 2" [51]

Monument Sign, M-10 Signbox Fabrication Details

285.05.12

Monument Sign, M-10 Signbox Fabrication Details 285.05.12

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings 0

0

1 1/2

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 14

Extruded alum. T-bar #GE-113

Extruded alum. filler #GE-111

Scale: 3"=1’-0"

Section 12

3

Inches

.125 Alum. back

3/16" x 1" neoprene gasket

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

.090 x 3/4 x 3/4 x 3" lg. Alum. hinge

Inches

1/4"

1/4" [6]

[6]

Scale: Half

0

0

1 1/2

3

Inches

Inches

Extruded alum. T-bar #GE-113

.125 Alum. back

1 1/2

Extruded Lexan "T" x 4" lg.

.090 x 1 1/2" long formed alum. face hold-back (typ.)

.125 fabricated alum. face tie-back w/ 7/16" x 3/4" slot for 3/8" dia. bolt (2-req’d. per face)

(1) 3/8" dia. hex. bolt, nut & lockwasher

TS: 5 x 5 x 3/8 column

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 15

#10 flat hd. csk selftapping screw @ 18" c/c

3/16" x 1" neoprene gasket (cont.)

Scale: 3"=1’-0"

Section 13

.315 Lexan face

Bent plate: 1 1/4 x 2 x 3/16 x 3" lg.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

3/16" x 1" neoprene gasket

.125 Alum. back

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

3

Extruded alum. filler #GE-111

Alum. angle: 2 x 2 x 3/16 x 5" lg. corner reinf. (Weld to filler)

Alum. angle: 2 x 2 x 3/16 x 2" lg. corner reinf. (Weld to filler) 2-req’d. @ each corner

Monument Sign, M-10 Signbox Fabrication Details

285.05.13

Monument Sign, M-10 Signbox Fabrication Details 285.05.13

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

15

19 sim.

15

18

8 3/4" [222] .250 flat cut-out alum. letters painted black, matte finish (bolt to face, see Letter Attachment Detail sheet 15) typ.

10’-9" [3277]

18’-8 3/8" [5699] (face)

15

19

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Front View 12

24

36

48

Inches

15

sim. 19

5/16" [8]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Dynamic Monogram (letters/curlicues): GE color G 02 C Grey opaque : Matte finish

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

3’-11 11/16" [1211]

c

Dynamic Monogram (field): GE color G 05 C Grey opaque (applied to 1st surface), matte finish

15

17

g GE Silicones

15

16

2’-11" [889]

3’-11 11/16" [1211]

Lexan "T" bar (typ. 2 places)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 clear Lexan face: Background: GE color G 02 C Grey opaque Matte finish on 1st surface

Laser Line: Film to match GE color Laser Red translucent applied to 1st surface (face clear behind Laser Line)

Monogram letters/curlicues: White translucent (face area behind Monogram remains clear)

Monogram field: Black opaque, matte finish

Cement Monogram to face behind opaque area only

8 3/4" [222] 2’-11" [889] 1’-3 3/4" 1’-1" 1’-5 1/2" [400] [330] [445]

18’-9" [5715] (retainer)

7’-6 9/16" [2300] (face)

5/16" [8]

1" [25]

5/32" [4] 7’-7" [2311] (retainer)

Monument Sign, M-10 Face Fabrication Elevation

4" [102] 3’-3" [991]

285, Facility Signs Engineering Drawings

9/32" [7]

GE Identity Program

285.05.14

Monument Sign, M-10 Face Fabrication Elevation 285.05.14

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5/16" [8]

Scale: Half

0

1/8" [3] 3

2’-11" [889] Monogram

1 1/2

Inches

7/16" [11]

Inches

face area behind Monogram

1/2" [13]

0 3

Inches

.315 clear Lexan face

(2)#6 x 3/4" Type BF thd. cutting screws w/ flat csk. hd.

Lexan "T" bar x 4" long (cement to face) 2-req’d. per face

.125 fabricated alum. face tie-back

5/16" [8]

Scale: Half

0

1/4" [6]

5/16" [8]

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

1 1/2

3

1 1/2

Inches

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd.

7/16" [11]

Drill & csk for #10 flat hd. self-tapping screws @ 18"c/c

Extruded Alum. retainer #GE-112

.315 Lexan lug cont. (cement to face)

#10 pan hd. self-tapping screws @ 18"c/c

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

0

Extruded Alum. "T" bar #GE-113

.315 Lexan face

Scale: 3"=1’-0"

Letter Attachment Detail

Section 19

5/16" [8]

1/8" [3] min.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 flat alum. angle: 3 x 3 x 3/4 corner stiffener (Weld one leg to retainer, pop rivet the other) typ. each corner

Extruded Alum. "T" bar #GE-113

#10 pan hd. self-tapping screws @ 18"c/c

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 1/2" lg. corner stiffener (Weld one leg to retainer, pop rivet the other) typ. ea. corner

Extruded Alum. retainer #GE-112

Drill & csk for #10 flat hd. self-tapping screws @ 18"c/c

Scale: 3"=1’-0"

1 1/2

3/8" [10]

1 1/4" [32]

Section 17

3/8" [10]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 18

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 Lexan face

.315 Lexan lug cont. (cement to face)

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd.

5/16" [8] 1/8" [3]

Scale: 3"=1’-0"

1 1/2

[3]

Section 16

.315 clear Lexan face decorated GE color G 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 2’-11" dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

Paint edge of alum. & acrylic black

1/8"

[13]

5/16" [8] Opaque Grey face 2’-10 3/4" [883] dia. clear

1/2"

1/4" [6] 1/4" [6]

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

3/8" [10]

285, Facility Signs Engineering Drawings 3/16" [5]

GE Identity Program 3/8" [10]

Monument Sign, M-10 Face Fabrication Details

285.05.15

Monument Sign, M-10 Face Fabrication Details 285.05.15

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-5 1/2" [444]

8 3/4" [222]

Letters: Black (typ.)

18’-9" [5715]

g

2’-11" [889]

Dynamic monogram letters/curlicues: GE color G 02 C Grey (typ.)

Scale: 1/8"=1’-0"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

24

48

8 3/4" [222]

8 3/4" [222]

72

96

c

GE Aircraft Engines

18’-9" [5715]

18’-9" [5715]

c Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

gGE Superabrasives

2’-11" [889]

Medium Length Name

g

2’-11" [889]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

c

GE Electrical Distribution & Control

18’-9" [5715]

Short Name

Dynamic Monogram field: GE color G 05 C Grey (typ.)

c

g GE Silicones

2’-11" [889]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Monogram letters/ curlicues: White (typ.)

Monogram field: Black (typ.)

2’-11" [889]

8 3/4" [222]

8 3/4" [222]

2’-4 7/16" [722] 1’-0" [305]

1" 1’-1" [25] [330]

8 3/4" [222]

2’-11" [889]

3’-1 1/4" [946]

1" [25]

8 3/4" [222] 8 3/4" [222] 6" 6" [152] [152]

1’-0" [305] 1’-4" 1’-4" 1’-4" [406] [406] [406]

8 3/4" [222] 8 3/4" [222]

8 3/4" [222] 2’-11" [889] 1" [25] 8 3/4" [222] 1’-4" 2’-11" [406] [889]

285, Facility Signs Engineering Drawings 1" [25]

1’-5 1/2" [444] 6 9/16" [167]

GE Identity Program 1’-5 1/2" [444]

Monument Sign, M-10 Sample Face Layouts

285.05.16

Monument Sign, M-10 Sample Face Layouts 285.05.16

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

12’-9" [3886]

15’-3 29/32" [4671]

Plan

10’-9 29/32" [3300]

Sign face

6’-9" [2057]

0

24

48

96

Inches

See sheet 33 for face fab. details

See Base Anchorage Detail sheet 22

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

See Detail A, sheet 22

1’-2 1/4" [362]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side Elevation

Disconnect switch

Back is hinged for service (GE color G 02 C Grey)

Filler: GE color G 02 C Grey, matte finish

External Lighting Fixtures: (2) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 3.24 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (3) GE F36T12 DL/HO Ballasts: (1) 3-Lamp Transformers: (1) 7500 Volt/60mA npf Amperage: 5.25 amps Circuits: (1) 20A/120V

Base: GE color Laser Red or GE color G 03 C Grey, matte finish. See sheet 25 for details

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

1’-3 29/64" [393]

1’-2 1/4" [362] to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

72

c

g GE Silicones

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish

4’-6" [1372]

Front Elevation

1’-3 29/64" [393]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from bldg.

See sheet 23 for foundation details

Finished Grade

Laser Line: GE color Laser Red translucent

Face background: GE color G 02 C Grey opaque, matte finish

Graphics: Black opaque, matte finish

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 29 for signbox fabrication details

[532]

Base field splice (typical)

6’-4 21/32" [1947] 7’-11 5/8" [2429] 1’-8 15/16"

7’-11 19/32" [2428] 6’-4 11/16" [1948]

1" offset for drainage

5’-1" [1549]

Base access door

1’-5 3/32" [434]

4’-6" [1372]

1’-5 7/8" [454] 8 3/4" [222]

10’-9 29/32" [3300]

1" [25]

285, Facility Signs Engineering Drawings

3’-0 17/32" [928]

GE Identity Program 6’-6 7/8" [2003]

Monument Sign, M-6 Sign Elevation & Installation Drawing

285.05.21

Monument Sign, M-6 Sign Elevation & Installation Drawing 285.05.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

3’-0" [914]

6’-9" [2057] (+/- 1’-0")

3’-6" [1067]

3’-0" [914]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/8"=1’-0"

0 48

72 96

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

24

Exterior Lighting Plan

Direct burial light fixture w/ 150 watt metal halide bulb (2-req’d.)

Sign base

Sign face

6

6" +/- [152]

3

1 1/2" [38]

0

6" [152]

9

12

1 1/2" [38]

Inches

Scale: 1 1/2"=1’-0"

0

3

Inches

Base foundation

3/8" dia. x 3 1/2" Hilti "Kwik-bolt" or equal (14-req’d. total)

Provide 1 1/2" x 1 1/2" alum. shim plates as req’d. to bring base up level with flat section of foundation under column (approx. 3/4")

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Base Anchorage Detail

Scale: 1"=1’-0"

Detail A

1 1/2" [38]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Sign base

Top of foundation

(2) 3/4" dia. hex. nuts & flat washers (8-req’d. per column)

3/4" dia. anchor bolt (See sheet 24 for details)

9" [229]

3/4" +/- [19]

TS: 4 x 4 x 3/16 column

Monument Sign, M-6 Installation & Lighting Details

1 1/2" [38] grout

GE Identity Program

285.05.22

Monument Sign, M-6 Installation & Lighting Details 285.05.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

6" 1’- ] 7 [45 3" 0’-

1 [31 24 ]

3/4 " 12

24

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

" ’-8

6] 6 [41

3" [76]

/4"

e3

p slo

48

Inches

9" [229]

o

Estimated Quantities Horizontal Slab and Base Foundation: Concrete: 6.0 cu. yds.

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4" dia. anchor bolt location

30

Outline of base foundation

Outline of base

Base anchorage plate (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

36

Front of sign

13

/4"

Scale: 1/4"=1’-0"

Plan

1’-3" [381]

4’-7 7/8" [1419]

" 3/4 3] [27

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1

"

3/4 e3

p slo

24

pe

slo

1’-6" [457]

pe

Outline of sign

Outline of flat & level concrete area @ top of foundation

Outline of column foundation

1’-6" [457]

3’-0" [914]

8’-3" [2515]

3 3/4" [95] typ.

6’-9" [2057]

3’-0" [914]

15’-9 1/8" [4804]

6’-0" [1829]

4’-4 1/4" [1327]

slo

3’-0" [914]

GE Identity Program 10

1’-3" [381]

Monument Sign, M-6 Foundation Plan

285.05.23

Monument Sign, M-6 Foundation Plan 285.05.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1’-6" [457]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electical conduit from bldg.

Scale: 1/4"=1’-0"

0

Section 1 12

24

36

Inches

Scale: 1"=1’-0"

0

3

9

Inches

projection grout

1 1/2" [38]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

12

TS: 4 x 4 x 3/16 column

Anchor Bolt Detail

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3/4" dia. anchor bolt w/ double hex. nuts & washers (8-req’d. total)

Top of foundation

48

6 x 6 - 6/6 welded wire fabric

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3’-0" [914]

See Anchor Bolt Detail

Finished Grade

3/4" [19] slope

Base 4 3/4" [121]

TS: 4 x 4 x 3/16 column (typ.)

[102]

8 3/4" [222] 4" 3’-0" [914]

6’-9" [2057]

Monument Sign, M-6 Foundation & Anchor Bolt Details

4" [102] 9" [229]

GE Identity Program

285.05.24

Monument Sign, M-6 Foundation & Anchor Bolt Details 285.05.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5’-0" [1524]

9’-0" [2743]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2" [51]

2 ’75 [80 /8" 3]

6 28

’-9

g)

9"

3’nin

pe

(O ]

43

[11

28

4

2

3’-6" [1067]

0

12

24

36

48

Inches

2]

[15

.

Angle: 2 x 2 x 3/16 (typ.)

Base field splice

1/2" dia. bolt, nut & lockwashers (typ.)

Covering shop splice (typ.)

Alum. angle: 1 x 1 x 1/8 x 3"lg. splice leveler @ 24" c/c (typ.)

Angle: 2 x 2 x 3/16 @ top, Bent plate: 2 x 2 x 3/16 @ bottom, this direction

See Front Right View on Sheet 26

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Angle: 2 x 2 x 3/16 @ bottom (cont.)

Bent plate: 2 x 2 x 3/16 (cont.)

typ

See Right Rear View on Sheet 26

Vert. angle: 2 x 2 x 3/16 (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(View Looking Perpendicular to Top)

Scale: 1/4"=1’-0"

32 1 [38 /64" 9]

1’-

6"

o

60

1’-0" [305]

2’-2" [660]

3’-6" [1067]

2’75 [80 /8" 3]

27

.250 Aluminum covering

3]

89

" [3

1/4

]

43

[11

Top View

2" [51]

12

9"

3’-

3’-6" [1067]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Plate: 1/4 x 4 x 6 w/ (1) 7/16" dia. hole for base anchorage (typ. 14 places)

See Front Left View on Sheet 26

Angle: 2 x 2 x 3/16, top only this direction

32 1 [38 /64" 9]

1’-

Covering shop splice (typ.)

Vert. angle: 2 x 2 x 3/16 (typ.)

Base field splice

27

3

1’-0" [305] 5 28

See Left Rear View on Sheet 26

1 1/2" [38]

12’-6" [3810]

5’-0" [1524]

4 Spaces @ 2’-0 1/2" [622] = 8’-2" [2489]

1’ 2 7 [37 /8" 8]

3’-6" [1067]

2’-2" [660]

1" [25 ]

Monument Sign, M-6 Base Framing Plan

1’-0" 1’-0"

3’-6" [1067]

285, Facility Signs Engineering Drawings 31 /2 [89 " ]

[305] [305]

GE Identity Program

285.05.25

Monument Sign, M-6 Base Framing Plan 285.05.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

9 15/32" [241]

Top of Base

1’-3 15/16" [405]

9’-0" [2743]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Front Left View

1’-7 7/8" [505]

2’-2 1/4" [667]

2’-2 1/4" [667]

2’-3 3/4" [705]

2’-5 11/32" [745]

2’-5 11/32" [745]

9 15/32" [241] 1’-3 15/16" [405]

2’-0 1/2" [622]

2’-0 1/2" [622]

2’-0 1/2" [622]

2’-0 1/2" [622]

2’-0 1/2" [622]

.250 alum. covering (typ.)

2’-0 1/2" [622]

12’-6" [3810]

0

12

24

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Front Right View 48

Inches

7

2’-2" [660]

2’-2" [660]

1’-9" [533]

28

Top of Base

2’-1 13/32" 1’-7 7/8" [645] [505]

3" [76]

11 1/4" [286]

3’-9 9/32" [1150]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Right Rear View

1/2" dia. bolt, nut, & lockwasher @ field splice (typ.)

Bent plate: 2 x 2 x 3/16 framing (typ. @ bottom of base)

3" [76]

Cont. piano hinge

3’-9 9/32" [1150]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

36

Angle: 2 x 2 x 3/16 framing (typ.)

2’-0 1/2" [622]

Left Rear View

2’-0 1/2" [622]

Base anchorage plate (typ.)

Top of Base

2’-2" [660]

2’-2" [660]

Top of Base

Southco keylatch

2’-0" [610] 9" [229]

1’-9" x 2’-0" access door

2’-5 25/32" [756] 2’-4 1/2" [724] 2’-4 1/2" [724]

285, Facility Signs Engineering Drawings 1’-9 7/32" [539]

GE Identity Program 2’-1 13/32" [645]

Monument Sign, M-6 Base Framing Elevations

285.05.26

Monument Sign, M-6 Base Framing Elevations 285.05.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

o

Scale: 3/4"=1’-0"

Section 2

12

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Angle: 2 x 2 x 3/16 cont.

Angle: 2 x 2 x 3/16 vert.

Bent plate: 2 x 2 x 3/16

1’-3 7

0

3] /8" [40

12

Inches

Scale: 3/4"=1’-0"

Section 3

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Bent plate: 2 x 2 x 3/16 cont.

Angle: 2 x 2 x 3/16 brace w/ 9/16" x 1" slot & (2) 1/2" dia. bolts, nuts & lockwashers each end (typ. 3 places)

Angle: 2 x 2 x 3/16 framing (typ.)

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

3 1/2" [89] 11 1/4" +/[286]

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Signbox

9]

11 1/4" +/[286]

285, Facility Signs Engineering Drawings 9" [22

3 1/2" [89]

GE Identity Program 6

12

6" [152]

Inches

1/2" dia. bolt, nut, lockwasher @ field splice (typ.)

Bent plate: 3 x 3 x 3/16 vertical corner

Angle: 2 x 2 x 3/16 framing (typ.)

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

3" [76]

Monument Sign, M-6 Base Framing Details

285.05.27

Monument Sign, M-6 Base Framing Details 285.05.27

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

5/32"

2’-5 2 [756]

Scale: 3/4"=1’-0"

Section 4

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 6

(2) Alum. angle: 1 x 1 x 1/8 x 3" lg. splice levelers

0

6

1 1/2

Inches

3

Inches

(1) 3/16" dia. bolt, nut, & lockwasher

typ. ea. end

Center line base covering shop splice

12

Bent plate: 2 x 2 x 3/16

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Plate: 1/4 x 4 x 6 for base anchorage

3/16

.250 alum. base covering

[102]

4"

Angle framing: 2 x 2 x 3/16

.250 alum. base covering w/ 1/4" dia. x 3/4" alum. studs, nuts, & washers @ 18" c/c (typ.)

1" [25]

.090 x 1 1/2" long fabricated alum. keeper w/ (2) 1/4" dia. x 3/4" flat hd. mach. screws & nuts

Scale: 3"=1’-0"

Section 5

1/8

13/16 x 1 1/4 x 6" lg. spacer bar

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

Section 7

1"

GE Identity Program [25]

1 1/2

0

1 1/2

Inches

3

Inches

.250 alum. access door

Southco low-profile, slam action keylatch (100 series) or equal

3

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

[28]

1 1/8"

5/8" [16]

0

Angle framing: 2 x 2 x 3/16

1/4" dia. x 3/4" alum. stud, nut, & washer @ 18" c/c (typ.)

.250 alum. base covering

Monument Sign, M-6 Base Framing Details

285.05.28

Monument Sign, M-6 Base Framing Details 285.05.28

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

(3) GE F36T12 DL/HO lamps

2’-10 1/4" [870]

32

11

1/2" dia. flex liquidtight conduit typ.

30

8

Scale: 3/8"=1’-0"

0

12

24

Inches

.125 fabricated alum. support bracket (typ. each end)

31

10

Alum. angle: 2 x 2 x 3/16 corner reinforcing (typ. ea. corner)

Extruded alum. filler #GE-111

1/2" dia. eyebolt for lifting (typ.) Replace w/ 1/2" dia. rd. hd. mach. screw after installation

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 3/4 x 9 x 10 1/2 w/(4) 7/8" dia. holes

TS: 4 x 4 x 3/16 column

Bent plate: 1 1/4 x 2 x 3/16 x 3" lg. (typ.)

32

12

3’-0" [914]

4’-3" [1295]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Front View

32

(1) 7500 volt/ 60 mA npf transformer in alum. trans. box

14

32

32

13

14 C3 x 5 for mounting transformer box

Extruded alum. T-bar #GE-113

(1) 3-lamp ballast in alum. ballast box & cover (f.s. of column)

6’-9" [2057]

4’-3" [1295]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Rigid electrical conduit from building

Disconnect switch

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

15 mm clear red neon tubing (Verify that neon will illuminate entire length of Laser Line) Neon tube length & position varies based on face layout

31

9

5" [127]

3’-0" [914]

4’-3" [1295]

2’-0" [610]

12’-9" [3886]

Monument Sign, M-6 Signbox Fabrication Drawing

5’-2" [1575]

Angle: 1 1/2 x 1 1/2 x 3/16 (typical top & bottom)

4 1/2" [114]

10 5/8"

2’-3" [686]

5 1/2" [140]

8" 8" [203] [203]

5 1/2" [140]

[270]

4’-5" [1346] (hinged back for service) 9" [229]

285, Facility Signs Engineering Drawings

1’-11 3/8" [594]

GE Identity Program

285.05.29

Monument Sign, M-6 Signbox Fabrication Drawing 285.05.29

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1" [25]

Scale: 1 1/2"=1’-0"

0

7 1/2" [190]

3" [76]

3

3/16

typ.

6 1/4" [159]

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 3/4 x 9 x 10 1/2

TS: 4 x 4 x 3/16 column

Rigid electrical conduit

Extruded alum. filler #GE-111

Bell flush disconnect switch #216-20-OG w/ Bell box #250

.125 Alum. formed backing bar (Weld lower section to back) cont.

3/16" x 1" neoprene gasket cont.

#10 flat hd. CSK self -tapping screw & tinnerman "J" nut @ 18" c/c

1/2" dia. flex. liquid tight conduit

PK housing

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. w/(1) 3/8" dia. hex. bolt, nut & lockwasher

.125 Alum. back

Cap plate: 1/4 x 5 x 9

3/16" x 1/2" neoprene gasket, cont.

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

.090 x 3/4 x 3/4 x 3" lg. alum. hinge (@ 3’-0" c/c) Rivet to filler, weld to retainer

1/2" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Section 8

3/16

2 3/4" [70]

8" [203]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1/2" dia. hex. hd. bolt, nut & lockwasher (4) req’d. per column Gage = 6"

Plate: 3/8 x 8 x 9 1/2

Provide 1/4" dia. weep holes as req’d.

.315 Lexan face: See sheet 33 for details

Angle: 1 1/2 x 1 1/2 x 3/16 x 7" lg. w/ (1) 3/8" dia. hex. bolt, nut & lockwasher in 7/16" x 3/4" slot (typ. n.s. & f.s.)

.090 Alum. neon baffle unit w/ end closures (Pop rivet to 1 1/2 x 1 1/2 x 3/16 x 5’-0" long back-up angle) Paint inside baffle white

(1) row of 15mm clear red neon tubing

1 1/4" tube stand as req’d.

10 5/8" [270] varies

3/16" x 3/4" cont. neoprene gasket (typ.)

.090 Alum. fluorescent lighting baffle unit (Paint inside white)

Angle: 1 1/2 x 1 1/2 x 3/16 lighting baffle suport

#10 flat hd. CSK self-tapping screws @ 18" c/c (typ.)

Extruded alum. retainer #GE-112

3 1/4" [83]

1/2" dia. rd. hd. mach. screw, nut & lockwasher (4-req’d. per column) gage = 7"

5/8" [16] 2" [51]

1’-2 1/4" [362]

4 3/4" [121] min.

285, Facility Signs Engineering Drawings 9" [229]

GE Identity Program 5/8" [16]

Monument Sign, M-6 Signbox Fabrication Details

285.05.30

Monument Sign, M-6 Signbox Fabrication Details 285.05.30

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5 3/4" [146]

2’-10 1/4" [870]

Scale: 1 1/2"=1’-0"

0 3

6

8" [203]

0

3

6

6" [152]

9

12

1 1/2" [38]

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1"=1’-0"

Section 10

TS: 4 x 4 x 3/16 column

Base plate: 3/4 x 9 x 10 1/2 w/ (4) 7/8" dia. holes

1 1/2" [38]

9" [229]

3/16" x 3/4" neoprene gasket, cont. all around

1/2" dia. x 1 1/2" short nipple w/ locknuts

1/2" dia. flex. conduit

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to column) typ. @ t & b of lighting baffle

(1) 3-lamp ballast, alum. ballast box & cover

.125 Alum. back

1 1/4" x 2" alum. raceway & cover Kulka socket #582-G

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

.125 x 2" cont. alum. back-up bar (Weld to non-hinged side of back)

.090 alum. light baffle unit

Kulka socket #583-G

(3) GE F36T12 DL/HO lamps

.125 Alum. back w/ #10 s.s. sht. metal screws 12" c/c (hinged for service)

Section 9

2" [51]

3’-2 1/4" [972]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.315 Lexan face

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Angle: 1 1/2 x 1 1/2 x 3/16 x 4’-4" lg. w/ (2) 3/8" dia. hex. bolts, nuts & lockwashers (Pop rivet to baffle unit) typ. t & b 4 1/2" [114]

1 1/4" [32]

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to filler) typ. @ t & b of lighting baffle

Extruded Alum. filler #GE-111

.090 x 3/4 x 3/4 x 3" lg. alum. hinge @ 1’-6" c/c (Weld to back, rivet to side)

3" [76]

1 1/2" [38] 7 1/2" [191]

285, Facility Signs Engineering Drawings

10 1/2" [267]

GE Identity Program 1 1/2" [38]

Monument Sign, M-6 Signbox Fabrication Details

285.05.31

Monument Sign, M-6 Signbox Fabrication Details 285.05.31

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings 0

0

1 1/2

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 13

Extruded alum. T-bar #GE-113

Extruded alum. filler #GE-111

Scale: 3"=1’-0"

Section 11

3

Inches

.125 Alum. back

3/16" x 1" neoprene gasket

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

.090 x 3/4 x 3/4 x 3" lg. Alum. hinge

Inches 1/4"

1/4" [6]

[6]

Scale: Half

0

0

1 1/2

3

Inches

Inches

Extruded alum. T-bar #GE-113

.125 Alum. back

1 1/2

Extruded Lexan "T" x 4" lg.

.090 x 1 1/2" long formed alum. face hold-back (typ.)

.125 fabricated alum. face tie-back w/ 7/16" x 3/4" slot for 3/8" dia. bolt (2-req’d. per face)

(1) 3/8" dia. hex. bolt, nut & lockwasher

TS: 4 x 4 x 3/16 column

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 14

#10 flat hd. csk selftapping screw @ 18" c/c

3/16" x 1" neoprene gasket

Scale: 3"=1’-0"

Section 12

.315 Lexan face

Bent plate: 1 1/4 x 2 x 3/16 x 3" lg.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Alum. angle: 1 1/8 x 1 1/4 x 1/8 cont.

3/16" x 1" neoprene gasket

.125 Alum. back

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

3

Extruded alum. filler #GE-111

Alum. angle: 2 x 2 x 3/16 x 5" lg. corner reinf. (Weld to filler)

Alum. angle: 2 x 2 x 3/16 x 2" lg. corner reinf. (Weld to filler) 2-req’d. @ each corner

Monument Sign, M-6 Signbox Fabrication Details

285.05.32

Monument Sign, M-6 Signbox Fabrication Details 285.05.32

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

6" [152] 34

18 sim.

34

.250 flat cut-out alum. letters painted black, matte finish (bolt to face, See Letter Attachment Detail sheet 34) typ.

6’-9" [2057]

12’-8 7/16" [3872] (face)

34

18

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

Front View 12

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Dynamic Monogram (field): GE color G 05 C Grey opaque (applied to 1st surface) matte finish

34

16

34

sim. 18

9/32" [7]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Dynamic Monogram (letters/curlicues): GE color G 02 C Grey opaque matte finish

c

2’-11 23/32" [907]

g GE Silicones

34

15

2’-0" [609]

Lexan "T" bar (typ. 2 places)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 clear Lexan face: Background: GE color G 02 C Grey opaque matte finish on 1st surface

Laser Line: Film to match GE color Laser Red translucent applied to 1st surface (face clear behind Laser Line)

Monogram letters/curlicues: White translucent (face area behind Monogram remains clear)

Monogram field: Black opaque matte finish

Cement Monogram to face behind opaque area only

17

6" [152]

2’-11 23/32" [907]

12’-9" [3886] (retainer)

5’-1 9/16" [1564] (face)

Monument Sign, M-6 Face Fabrication Elevation

3/16" [5] 5’-2" [1575] (retainer)

9/32" [7]

3/4" [19]

2’-0" [609] 1’-0" [305] 10 1/4" 9" [260] [229]

4" [102] 1’-11 1/2" [597]

285, Facility Signs Engineering Drawings

1/4" [6]

GE Identity Program

285.05.33

Monument Sign, M-6 Face Fabrication Elevation 285.05.33

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5/16" [8]

Scale: Half

0

1/8" [3] 3

2’-0" [610] Monogram

1 1/2

Inches

7/16" [11]

Inches

face area behind Monogram

1/2" [13]

0 3

Inches

.315 clear Lexan face

(2)#6 x 3/4" Type BF thd. cutting screws w/ flat csk. hd.

Lexan "T" bar x 6" long (cement to face) 2-req’d. per face

.125 fabricated alum. face tie-back

5/16" [8]

Scale: Half

0

1/4" [6]

5/16" [8]

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

1 1/2

3

1 1/2

Inches

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd. @ 12" c/c

7/16" [11]

Drill & csk. for #10 flat hd. self-tapping screws @ 18"c/c

Extruded Alum. retainer #GE-112

.315 Lexan lug cont. (cement to face)

#10 pan hd. self-tapping screws @ 18"c/c

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

0

Extruded Alum. "T" bar #GE-113

.315 Lexan face

Scale: 3"=1’-0"

Letter Attachment Detail

Section 18

5/16" [8]

1/8" [3] min.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 flat alum. angle: 3 x 3 x 3/4 corner stiffener (Weld one leg to retainer, pop rivet the other) typ. each corner

Extruded Alum. "T" bar #GE-113

#10 pan hd. self-tapping screws @ 18"c/c

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 1/2" lg. corner stiffener (Weld one leg to retainer, pop rivet the other) typ. ea. corner

Extruded Alum. retainer #GE-112

Drill & csk. for #10 flat hd. self-tapping screws @ 18"c/c

Scale: 3"=1’-0"

1 1/2

3/8" [10]

1 1/4" [32]

Section 16

3/8" [10]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 17

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 Lexan face

.315 Lexan lug cont. (cement to face)

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd. @ 12" c/c

5/16" [8] 1/8" [3]

Scale: 3"=1’-0"

1 1/2

[3]

Section 15

.315 clear Lexan face decorated GE color G 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 2’-0" dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

1/8"

[13]

5/16" [8] 1/2"

Opaque Grey face 1’-11 3/4" [603] dia. clear

Paint edge of alum. & acrylic black

3/32" [2]

1/4" [6] 1/4" [6]

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

1/4" [6]

285, Facility Signs Engineering Drawings 5/32" [4]

GE Identity Program 1/4" [6]

Monument Sign, M-6 Face Fabrication Details

285.05.34

Monument Sign, M-6 Face Fabrication Details 285.05.34

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-0" [305]

6" [152]

g

2’-0" [609]

Dynamic Monogram letters/curlicues: GE color G 02 C Grey (typ.)

0

12

24

6" [152]

36

48

6" [152]

c

GE Aircraft Engines

12’-9" [3886]

12’-9" [3886]

c Inches

4 1/2" [114]

1’-0" 1’-0" 1’-0" [305] [305][305]

6" [152]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

gGE Superabrasives

2’-0" [609]

Medium Length Name

g

2’-0" [609]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3/16"=1’-0"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

Face Layouts

c

GE Electrical Distribution & Control

12’-9" [3886]

Short Name

Dynamic Monogram field: GE color G 05 C Grey (typ.)

c

Letters: Black (typ.)

12’-9" [3886]

g GE Silicones

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Monogram letters/ curlicues: White (typ.)

Monogram field: Black (typ.)

6" [152]

2’-0" [609]

2’-0" [609]

6" [152] 6" 4" 4" [102] [102] [152]

6" [152]

8 1/4" [210]

3/4" 9" [19] [229]

6" [152]

2’-0" [609]

2’-0 3/4" [629]

3/4" [19]

8" [203] 11" 11" 11" [279] [279] [279]

6" [152] 2’-0" [609] 1’-7 1/2" [495] 3/4" [19] 6" [152] 11" 2’-0" [279] [609]

285, Facility Signs Engineering Drawings 3/4" [19]

GE Identity Program 6" [152]

Monument Sign, M-6 Sample Face Layouts

285.05.35

Monument Sign, M-6 Sample Face Layouts 285.05.35

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail, sheet 04

See sheet 04 & 05 for foundation and anchor bolt details

Finished Grade

2’-6" [762]

24

48

72

1/2" [13] 96

Inches

clearance

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

0

04

2

04

1

GE Plastics

g

Front Elevation

Rigid electrical conduit from building

TS-12 x 12 x 3/8 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 07 for signbox fabrication drawing

11’-6" [3505] 3" [76]

11’-6" [3505]

1’-3" [381] 17’-0" [5182]

285, Facility Signs Engineering Drawings 30’-0" [9144]

Lamps: (20) GE F72T12 DL/HO Ballasts: (4) 5-lamp ballasts Amperage: 19.25 amps Circuits: (2) 20A/120V circuits

Electrical Information

Pole Sign, C-12 Sign Elevations - 30 ft. Overall Height

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Disconnect switch

Faces hinged for service

Sign filler: White to match face

Side Elevation

1’-5 1/4" [438]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1’-0" [305]

GE Identity Program

285.07.01

Pole Sign, C-12 Sign Elevations - 30 ft. Overall Height 285.07.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail, sheet 04

See sheet 04 & 05 for foundation and anchor bolt details

Finished grade

2’-6" [762]

24

48

72

1/2" [13] 96

Inches

clearance

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

0

04

2

04

1

GE Plastics

g

Front Elevation

Rigid electrical conduit from building

TS-12 x 12 x 3/8 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

11’-6" [3505]

1’-3" [381] 22’-0" [6706]

11’-6" [3505] 3" [76]

GE Identity Program 35’-0" [10668]

Lamps: (20) GE F72T12 DL/HO Ballasts: (4) 5-lamp ballasts Amperage: 19.25 amps Circuits: (2) 20A/120V circuits

Electrical Information

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Disconnect switch

Faces hinged for service

Sign filler: White to match face

Side Elevation

1’-5 1/4" [438]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1’-0" [305]

See sheet 07 for signbox fabrication drawing

Pole Sign, C-12 Sign Elevations - 35 ft. Overall Height

285.07.02

Pole Sign, C-12 Sign Elevations - 35 ft. Overall Height 285.07.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2 04

Scale: 3/32"=1’-0"

0

24

48

Front Elevation

2’-6" [762]

04

1

GE Plastics

g

72

1/2" [13] 96

Inches

clearance

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

See Anchor Bolt Detail, sheet 04

See sheet 04 & 05 for foundation and anchor bolt details

Finished grade

Rigid electrical conduit from building

TS-12 x 12 x 3/8 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 07 for signbox fabrication drawing

11’-6" [3505] 40’-0" [12192]

Disconnect switch

Faces hinged for service

Sign filler: White to match face

Side Elevation

1’-5 1/4" [438]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3" [76]

11’-6" [3505]

1’-3" [381] 27’-0" [8230]

GE Identity Program Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Lamps: (20) GE F72T12 DL/HO Ballasts: (4) 5-lamp ballasts Amperage: 19.25 amps Circuits: (2) 20A/120V circuits

Electrical Information

Pole Sign, C-12 Sign Elevations - 40 ft. Overall Height

285.07.03

Pole Sign, C-12 Sign Elevations - 40 ft. Overall Height 285.07.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

0 3

6

Inches

1/8"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

8" [203]

1’-5 1/4" [438]

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

L: 2 x 2 x 3/16 w/ 3/16" dia. x 3/4" lg. pins welded to angle

.125 x 2 1/2" alum. backing bar, cont. weld one side & rivet w/ 3/16" pop rivets @ 18" c/c other side

Column TS: 12 x 12 x 3/8

.125 alum. escutcheon

Alum. angle: 2 x 1 x 1/8 (typ.) (weld to escutcheon) cont.

Pop rivet to alum. channel @ 18" c/c

1" [25] 2" [51]

7/8" dia. hex bolt, nut & flat washer (weld both in place)

3" [76]

L: 2 x 2 x 3/16 x 2’-0" w/ 3/16" dia. pins welded to angle @ 5 1/2" c/c

Column TS: 12 x 12 x 3/8

3/16" dia. pop rivets @ 18" c/c

.125 alum. column cladding (fit over alignment pins @ splice points)

6" 6" 6" [152] [152] [152] 2 1/2" [63]

Section 2 0

typ.

6

6

12

12

24

Inches

18

Inches

2" grout [51]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

0

2’-6" [762]

Scale: 1/2"=1’-0"

Anchor Bolt Detail

1 3/8" dia. anchor bolt w/ dbl. heavy hex nuts & washers (8-bolts total)

Top of footing

TS: 12 x 12 x 3/8 column

2 1/2" [63]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

typ.

1’-3" [381]

6" [152] 1’-6" [457] 8 5/8" [219]

285, Facility Signs Engineering Drawings

8 5/8" [219]

GE Identity Program 1’-5 1/4" [438]

Pole Sign, C-12 Installation & Anchor Bolt Details

285.07.04

Pole Sign, C-12 Installation & Anchor Bolt Details 285.07.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

0

12

24

48

Inches

1’-6" [457] to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities 1. Horizontal slab foundations Concrete = 12.4 cu. yds.

Scale: 1/4"=1’-0"

36

3’-6" [1067]

Front Elevation

3’-6" [1067]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from building

See Anchor Bolt Detail, sheet 04

Coat column under grade & anchor bolts w/ waterproofing material

Finished grade

TS: 12 x 12 x 3/8 column

7’-0" [2134]

1’-0" [305] 4’-0" [1219]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1/4"=1’-0"

Plan

1 3/8" dia. anchor bolt location (8-req’d.)

Signbox above

Electrical conduit stubout location

0

12

1’-11" [584] 6" [152]

24

36

6" [152] 2 1/2" [63]

3’-6" [1067]

48

1’-10" [559] Inches

12’-0" [3658]

6’-0" [1829] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6" [152] 2 1/2" [63]

3’-6" [1067]

7’-0" [2134]

Pole Sign, C-12 Foundation Drawing

2 1/2" [64] 1’-5" [432] 2 1/2" [64]

285, Facility Signs Engineering Drawings

6’-0" [1829]

GE Identity Program

285.07.05

Pole Sign, C-12 Foundation Drawing 285.07.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3

06

2’-6" [762]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3/16"=1’-0"

0

Front View

Base plate: 1 3/8 x 22 x 23

Column TS: 12 x 12 x 3/8

L: 2 x 2 x 3/16 x 2’-0" cladding support (typ.)

.125 alum. column cladding

Cladding splice (2) @ equal spaces for 35’-0" & 40’-0" heights; 1 @ equal spaces for 30’-0" height

.125 alum. escutcheon

24

2

4

36

06

04

48

Inches

29’-4" [8941] (for 40’-0" mt. height)

5" [127] 1’-1" [330]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

12

1 04

3" [76] 1’-3" [381] 10 1/2" [267]

Signbox

11’-6" signbox 19’-4" [5893] (for 30’-0" mt. height), 24’-4" [7417] (for 35’-0" mt. height),

5’-9" [1753]

1/8

Scale: 3/4"=1’-0"

0

12

6

12

1’-0" [305] Inches

2 1/2" [63]

Inches

1’-10" [559] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 4

6" [152] 6" [152] 6" [152]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3/8 x 5 x 8 gusset plate (typ.)

typ.

2" dia. wiring hole

Column TS: 12 x 12 x 3/8

Base plate: 1 3/8 x 22 x 23 w/ (8) 1 5/8" dia. holes for 1 3/8" dia. anchor bolts

6

2" [51]

11 1/2" [292]

1’-11" [584] 11 1/2" [292]

Scale: 3/4"=1’-0"

0

4" 4" [102] [102]

Section 3

2 1/2" [63]

Column TS: 12 x 12 x 3/8 (below)

2" dia. wiring hole

Cap plate: 3/4 x 12 x 12 w/ (6) 7/8" dia. hex bolts welded inside

2" [51]

1’-0" [305]

2" [51] 4" 4" [102] [102] 2" [51]

5’-9" [1753]

11’-6" [3505]

2 1/2" [63] 1’-5" [432]

285, Facility Signs Engineering Drawings

11" [279]

GE Identity Program 2 1/2" [63]

11" [279]

Pole Sign, C-12 Column & Column Covering Drawing

285.07.06

Pole Sign, C-12 Column & Column Covering Drawing 285.07.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 09

6

6" [152]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

5’-9" [1753]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

12

7

24

09

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3/8"=1’-0"

Front View

08

5

9 spaces @ 1’-2" = 10’-6" [3200] (lamp spacing) Lifting angle: 3 x 3 x 5/16

Note: Face and retainer not shown

Bell flush disconnect switch #216-20-OG w/ Bell box #250

Kulka socket #582-G (typ.)

Face prop rod assembly (typ.)

(4) 5-lamp ballast in alum. ballast box

Base plate: 3/4 x 12 x 12

1/2" flex. conduit (typ.)

1/2" dia. conduit from bldg.

Column TS: 5 x 5 x 3/8

1 1/4" x 2 1/2" alum. raceway fs

TS: 4 x 2 x 3/16

1 1/4" x 2 1/2" alum raceway ns

L: 2 x 2 x 1/4 x 2" lg., support connection angle

(20) GE F72T12 DL/HO lamps

Kulka socket #583-G (typ.)

(2) alum. angles: 2 x 2 x 3/16 x 2" lg., (1) alum. angle: 2 x 2 x 3/16 x 5" lg., corner reinforcement (weld to filler) typ. each end

5’-9" [1753] 6" [152]

11’-6" [3505] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6 1/2" [165]

Extruded alum. filler #GE-111

5’-9" [1753] 5’-9" [1753]

GE Identity Program 5" [127]

11’-6" [3505]

Pole Sign, C-12 Signbox Fabrication Drawing

285.07.07

Pole Sign, C-12 Signbox Fabrication Drawing 285.07.07

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1 1/2"=1’-0"

Section 5

typ.

0

3

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Plate: 3/4 x 12 x 12

Alum. escutcheon: see sheet 04 for fabrication details

Alum. channel: 1 3/4 x 1 x 1/8, weld to support angle

#10 thd. cutting screws @ 18" c/c (typ.) remove to hinge face

Alum. spacer 1/8 x 2 cont. (typ.)

(4) 1/2" dia. hex bolt, nut & washer (8 gage)

Plate: 3/8 x 5 x 5 ns & fs

1 1/4" x 2 1/2" alum. raceway & cover (rivet to support angle)

TS: 4 x 2 x 3/16 (ns & fs of column)

3/8" dia. hex bolt, nut & washer (typ.)

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c (typ.)

Cap plate: 3/8 x 5 x 12

.090 x 1 1/2 x 1 1/2 x 4" lg. alum. hinge (5 per face) w/ (3) #10 flat hd. self-tapping screws @ filler, rivet to face frame w/ 3/16" dia. csk. rivets

L: 3 x 3 x 5/16 x 1’-0" lg. w/ (2) 3/4" dia. hex bolt, nut & washer; lifting angle w/ (2) 1" dia. holes (remove after installation & replace bolt) nuts welded inside

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3 1/2" [89]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. angle: 2 x 2 x 3/16 cont. rivet to filler @ 18" c/c (typ.)

Alum. angle: 1 x 1 x 1/8, rivet to cover @ 18" c/c (typ.)

Signbox column TS: 5 x 5 x 3/8

Kulka socket #582-G (typ.)

Support angle: 2 x 2 x 1/8 cont. (typ.) rivet to tube @ 18" c/c

(20) GE F72T12 DL/HO lamps

1 x 1 x 1/8 alum. tube support weld together @ junction

3M Panaflex 945 Series flex. sign face

Kulka socket #583-G (typ.)

Signtech FS-P frame support @ center of sign face (horiz. & vert.)

Signtech extruded alum. CTS hammer frame #NCTRF-10LG

Signtech extruded alum. frameless cover #NCTR3FC-40 w/ flat hd. sht. metal screws @ 18" c/c (notch cover around hinges)

Extruded alum. filler #GE-111

1’-5 1/4"

Pole Sign, C-12 Signbox Fabrication Details

285.07.08

Pole Sign, C-12 Signbox Fabrication Details 285.07.08

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3 1/2" [89]

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1 1/2"=1’-0"

Section 6 6

Inches

Scale: 1 1/2"=1’-0"

Section 7

4" [102]

0

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

2" dia. wiring hole

Signbox column TS: 5 x 5 x 3/8

Plate: 3/4 x 12 x 12

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

Plate: 3/8 x 5 x 9

TS: 4 x 2 x 3/16

(4) 1/2" dia. hex hd. mach. screws, hex nuts & washers (6 1/2" gage) typ. each end of sign

Extruded alum. filler #GE-111

2" [51]

2" [51]

6

Inches

1’-0" [305] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

4" [102]

1’-0" [305]

Pole Sign, C-12 Signbox Fabrication Details

2" [51] 4" [102] 4" [102]

285, Facility Signs Engineering Drawings

2" [51]

GE Identity Program

285.07.09

Pole Sign, C-12 Signbox Fabrication Details 285.07.09

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

11 1/2" [292]

11 1/2" min. [292]

11 1/2" min. [292]

Scale: 1/8"=1’-0"

0

48

72

96

Inches

11 1/2" [292]

11 1/2" [292]

11 1/2" min. [292]

11 1/2" min. [292]

11’-6" [3505]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

GE Superabrasives

g

2’-10 1/2" [876]

11’-6" [3505]

Medium Length Name

GE Aircraft Engines

g

2’-10 1/2" [876]

11’-6" [3505]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

Face Layouts

11’-6" [3505]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

g

2’-10 1/2" [876]

11’-6" [3505]

Short Name

GE Silicones

g

2’-10 1/2" [876]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

11 1/2" [292]

11’-6" [3505]

1’-4 1/2" [419] 1’-0 3/8" [314] 5 7/16" [138] (typ.)

11 1/2" [292] 2’-3 5/8" 1" 2’-10 1/2" 2’-10 1/2" [876] [702] [25] [876] 1’-2 1/2" [368] (typ.) 10 7/8" [276]

11’-6" [3505] 11 1/2" [292] 2’-10 1/2" [876] 1" 1’-2 1/2" [25] [368] 11 1/4" [286]

6 3/4" [171] 1’-6 1/4" [464] (typ.) 5" [127]

1’-6 1/4" [464] 1’-1 5/8" [346] 1’-1 1/4" [337] (typ.) 9 15/16" [252]

11 1/2" [292] 2’-10 1/2" [876] 1" [25] 1’-3 7/8" [403] 11 1/2" [292] 1" 2’-2 1/2" 2’-10 1/2" [25] [673] [876]

285, Facility Signs Engineering Drawings

1’-11 1/16" [586]

GE Identity Program 11’-6" [3505]

Pole Sign, C-12 Sample Face Layouts

285.07.10

Pole Sign, C-12 Sample Face Layouts 285.07.10

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail, sheet 24

See sheet 24 & 25 for foundation and anchor bolt details

Finished Grade

Scale: 3/16"=1’-0"

0

12

24

Front Elevation

1’-6" [457]

24

2

24

1

GE Turbine

g

36

48

Inches

1/2" [13]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Rigid electrical conduit from building

TS: 8 x 8 x 5/16 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 27 for signbox fabrication drawing

7’-1 1/2" [2172]

9" [229] 11’-11 1/2" [3645]

285, Facility Signs Engineering Drawings clearance

7’-1 1/2" [2172]

1’-2" [356]

Disconnect switch

Faces hinged for service

Sign filler: White to match face

Side Elevation

20’-0" [6096] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

2" [51]

GE Identity Program Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Lamps: (8) GE F84T12 DL/HO Ballasts: (2) 4-lamp ballasts Amperage: 7.7 amps Circuits: (1) 20A/120V circuits

Electrical Information

Pole Sign, C-7 Sign Elevations - 20 ft. Overall Height

285.07.21

Pole Sign, C-7 Sign Elevations - 20 ft. Overall Height 285.07.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See Anchor Bolt Detail, sheet 24

See sheet 24 & 25 for foundation and anchor bolt details

Finished Grade

2 24

Scale: 3/16"=1’-0"

0

12

24

Front Elevation

1’-6" [457]

24

1

GE Turbine

g

36

48

Inches

1/2" [13]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Rigid electrical conduit from building

TS: 8 x 8 x 5/16 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 27 for signbox fabrication drawing

9" [229] 16’-11 1/2" [5169] clearance

GE Identity Program 7’-1 1/2" [2172] 25’-0" [7620]

Disconnect switch

Faces hinged for service

Sign filler: white to match face

Side Elevation

1’-2" [356]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

2" [51]

7’-1 1/2" [2172]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Lamps: (8) GE F84T12 DL/HO Ballasts: (2) 4-lamp ballasts Amperage: 7.7 amps Circuits: (1) 20A/120V circuits

Electrical Information

Pole Sign, C-7 Sign Elevations - 25 ft. Overall Height

285.07.22

Pole Sign, C-7 Sign Elevations - 25 ft. Overall Height 285.07.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

24

2

48

24

1/2" [13] 72

96

clearance Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

0

1 24

1’-6" [457]

GE Turbine

g

Front Elevation

See Anchor Bolt Detail, sheet 24

See sheet 24 & 25 for foundation and anchor bolt details

Finished Grade

Rigid electrical conduit from building

TS: 8 x 8 x 5/16 column

Column cladding splice

Column cladding & escutcheon: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 27 for signbox fabrication drawing

7’-1 1/2" [2172]

9" [229] 21’-11 1/2" [6693]

7’-1 1/2" [2172] 2" [51] 30’-0" [9144]

GE Identity Program Disconnect switch

Faces hinged for service

Sign filler: White to match face

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Side Elevation

1’-2" [356]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Lamps: (8) GE F84T12 DL/HO Ballasts: (2) 4-lamp ballasts Amperage: 7.7 amps Circuits: (1) 20A/120V circuits

Electrical Information

Pole Sign, C-7 Sign Elevations - 30 ft. Overall Height

285.07.23

Pole Sign, C-7 Sign Elevations - 30 ft. Overall Height 285.07.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

Scale: 1 1/2"=1’-0"

0

1’-2" [356]

3

6

Inches

1/8"

typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Column TS: 8 x 8 x 5/16

L: 2 x 2 x 1/8 w/ 3/16" dia. x 3/4" lg. pins welded to angle

.125 alum. escutcheon

.125 x 2 1/2" alum. backing bar cont. weld one side & rivet w/ 3/16" dia. pop rivets @ 18" c/c other side

5/8" dia. hex bolt, nut & washer (weld bolt in place) 4-req’d.

Alum. angle: 1 x 1 x 1/8 (typ.) weld to escutcheon

Rivet to alum. channel @ 18" c/c 1" [25] 1" [25]

Signbox

6" [152]

2" [51] 9" [229]

Scale: 1"=1’-0"

0

3

6

typ.

1’-6" [457]

0

9

9" [229]

6

12

12

Inches

Inches

2" [51]

1’-2" [356] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 2

9" [229]

Scale: 3/4"=1’-0"

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

L: 2 x 2 x 1/8 x 1’-0" w/ 3/16" dia. x 3/4" pins welded to angle @ 3" c/c

Column TS: 8 x 8 x 5/16

3/16" dia. rivets @ 18" c/c

.125 alum column cladding (fit over alignment pins @ splice points)

4" 4" 4" [102] [102] [102]

Anchor Bolt Detail

7/8" dia. anchor bolt w/ dbl. heavy hex nuts & washers (8 bolts total)

Top of footing

TS: 8 x 8 x 5/16 column

2" [51]

2" grout [51]

7" [178] 7" [178]

GE Identity Program 1’-0" [305]

5" [127]

Pole Sign, C-7 Installation & Anchor Bolt Details

285.07.24

Pole Sign, C-7 Installation & Anchor Bolt Details 285.07.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

0 12

Inches

1’-6" [457] to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Concrete: 6.2 cu. yds.

Estimated Quantity

Scale: 3/8"=1’-0"

24

2’-6" [762]

Front Elevation

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from building

See Anchor Bolt Detail, sheet 24

Coat column under grade & anchor bolts w/ waterproofing material

Finished grade

TS: 8 x 8 x 5/16 column

2’-6" [762]

5’-0" [1524]

1’-0" [305] 4’-0" [1219]

Scale: 3/8"=1’-0"

Plan

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Electrical conduit stubout location

Signbox above

4" [102]

2’-6" [762]

12

2" [51]

4" [102]

2’-6" [762]

24

Inches

8’-6" [2591]

4’-3" [1295] 1’-4" [406]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

4" [102]

1’-4" [406]

5’-0" [1524]

Pole Sign, C-7 Foundation Drawing

2" [51] 1’-0" [305] 2" [51]

285, Facility Signs Engineering Drawings

4’-3" [1295]

GE Identity Program

285.07.25

Pole Sign, C-7 Foundation Drawing 285.07.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

12

1’-6" [457]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/4"=1’-0"

0

Front View

Base plate: 1 x 16 x 16

Column TS: 8 x 8 x 5/16

L: 2 x 2 x 1/8 x 1’-0" cladding support (typ.)

Cladding splice (2 @ equal spaces for 30’-0" height; 1 @ equal space for 20 & 25 ft. height)

.125 alum. column cladding

.125 alum. escutcheon

Signbox

36

3

26

4

24

2

26

48

Inches

1" typ. [25]

7’-1 1/2"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

24

1 24

5" [127] 6" [152]

3’-6 3/4" [1086]

signbox 23’-8" [7226] (for 30’-0" mt. height)

7’-1 1/2" [2172]

3’-6 3/4" [1086]

1/8

Scale: 1"=1’-0"

0

6

9

4" 2" [102] [51]

9

12

12

Inches

Inches

1’-4" [406] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

4" [102]

Section 4

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

typ.

2" dia. wiring hole

Column TS: 8 x 8 x 5/16

3/8 x 4 x 8 gusset plate: (typ.)

Base plate: 1 x 16 x 16 w/ (8) 1" dia. holes for 7/8" dia. anchor bolts

2" 4" [51] [102]

6

1/2" [13]

1 1/2" [38]

8" [203]

1’-4" [406]

0

8" [203]

Scale: 1"=1’-0"

3

3" 3" [76] [76]

Section 3

Column TS: 8 x 8 x 5/16 (below)

2" dia. wiring hole

Cap plate: 5/8 x 9 x 9 w/ (4) 5/8" dia. hex bolts welded inside

1/2" [13]

1 1/2" [38]

9" [229]

1/2" [13] 1/2" [13]

2" [51] 9" [229] 10 1/2" [267]

1 1/2" [38] 3" 3" [76] [76] 1 1/2" [38] 2" [51] 1’-0" [305]

9" [229] 8" [203] 8" [203]

285, Facility Signs Engineering Drawings

2" [51]

GE Identity Program 13’-8 1/2" [4178] (for 20’-0" mt. height); 18’-8 1/2" [5702] (for 25’-0" mt. height);

Pole Sign, C-7 Column & Column Covering Drawing

285.07.26

Pole Sign, C-7 Column & Column Covering Drawing 285.07.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1/4" dia. weep holes as req’d.

Kulka socket #582-G

Face prop rod assembly (typ.)

1/2" dia. flex conduit (typ.)

(2) 4-lamp ballasts

Column TS: 3 x 3 x 1/4

Extruded alum. filler #GE-111

1 1/4" x 4" alum. ballast box & cover (typ.)

(8) GE F84T12 DL/HO lamps

Kulka socket #583-G

Alum. angle: 2 x 2 x 3/16 corner stiffener (2) x 2" lg.; (1) x 5" lg. (typ. each corner)

Lifting angle: 2 x 2 x 3/16 x 1’-0" w/ (2) 1" dia. holes (remove after installation)

3’-6 3/4" [1086]

6

Scale: 1/2"=1’-0"

0

Front View

28

6

18

24

Inches

Bell flush disconnect switch #216-20-OG w/ Bell box #250

6" [152]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

28

5

7 spaces @ 10 1/2" [267] = 6’-1 1/2" [1867]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6" [152]

3’-6 3/4" [1086]

7’-1 1/2" [2172] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

5" [127]

7’-1 1/2" [2172]

Pole Sign, C-7 Signbox Fabrication Drawing

285.07.27

Pole Sign, C-7 Signbox Fabrication Drawing 285.07.27

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Plate: 5/8 x 9 x 9

Alum. channel: 1 1/4 x 1 1/4 x 1/8 cont. (weld to L: 1 3/4 x 1 3/4 x 1/8) typ.

#10 thd. cutting screws @ 18" c/c (typ.)

Alum. angle: 1 x 1 x 1/8 cont. (rivet to retainer @ 18" c/c) typ.

Extruded alum. retainer clip #GE119 w/ #10 sht. metal screws @ 18" c/c (typ.)

Plate: 3/8 x 5 x 9 w/ (2) 1/2" dia. hex hd. bolts, nuts & washers @ 6" c/c

TS: 3 x 3 x 1/4

.315 clear Lexan face w/ White translucent film on 2nd surface

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c

Plate: 3/8 x 5 x 12

.090 x 1 1/2 x 1 1/2 alum. hinge x 3" lg. (4-req’d. @ each face) weld to retainer, rivet to filler

(2) 1/2" dia. hex hd. bolts, nuts & washers @ 9" c/c (weld nuts inside) replace after angle removal

0

1 1/2

3

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Section 5

1’-2" [356]

1 1/2" [38]

0

3

6

9

12

1 1/2" [38]

Inches

9" [229] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1"=1’-0"

9" [229] 3" 3" [76] [76]

Section 6

TS: 3 x 3 x 1/4 column

1 1/2" dia. wiring hole

Plate: 5/8 x 9 x 9 w/ (4) 3/4" dia. holes for 5/8" dia. bolts

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Alum. angle: 1 3/4 x 1 3/4 x 1/8 cont. (rivet to filler @ 18" c/c) typ.

typ.

1/8" x 1/2" cont. neoprene gasket (typ.)

Extruded alum. retainer #GE-118

Extruded alum. filler #GE-111

1/4" [6]

Lifting angle: 2 x 2 x 3/16 x 1’-0" long

1 1/2" [38] 3" 3" [76] [76]

GE Identity Program 1 1/2" [38]

Pole Sign, C-7 Signbox Fabrication Details

285.07.28

Pole Sign, C-7 Signbox Fabrication Details 285.07.28

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

similar

30

9

7 30

g

1’-9" [533]

Scale: 3/8"=1’-0"

12

24

Inches

similar

30

9

15/16" [24] 2" typ. [51]

5/8" [16] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Front View

30

9

GE Turbine

7" [178]

6’-11 5/8" [2124] face

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Laser Line: film to match GE color Laser Red translucent applied to 1st surface

.250 flat cut-out alum. letters painted Black, matte finish (bolt to face, see Letter Attachment Detail, sheet 30) typ.

.315 clear SG-100 Lexan face w/ White translucent 3M film #3630-20 on 2nd surface

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

Cement Monogram to face behind opaque areas only

30

8

15/16" [24]

7’-1 1/2" [2172] retainer

7" [178] 1’-9" [533] 1’-9" [533] 8 1/4" 11" [210] [279]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1’-4 5/8" [422]

15/16" [24] 6’-11 5/8" [2124] face 15/16" [24]

285, Facility Signs Engineering Drawings

~

Pole Sign, C-7 Face Fabrication Elevation

7’-1 1/2" [2172] retainer

GE Identity Program

285.07.29

Pole Sign, C-7 Face Fabrication Elevation 285.07.29

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5/16" [8]

.315 clear Lexan face w/ White translucent film on 2nd surface

Extruded alum. retainer clip #GE-119

Scale: 3"=1’-0"

Section 7

.090 alum. overlay @ Monogram field: Black, matte finish

Monogram letters/curlicues.375 clear acrylic w/ polished edges (cement to clear acrylic back-up)

Scale: 3"=1’-0"

Section 9

0

1/8" [3]

0

1 1/2

3

Inches

Inches

#4 x 1/2"- type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

Extruded alum. retainer #GE-118

.315 x 1/4" Lexan lug cont. (cement to face)

#10 pan hd. self-tapping screw @ 18" c/c

3

.315 clear Lexan face w/ White translucent film on 2nd surface

.125 clear acrylic x 1’-9" dia. (cement to face behind opaque areas only)

3/16" alum. stud welded to overlay w/ washer & elastic stop-nut (as req’d. to maintain adequate attachment of alum. to acrylic)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

1 7/8" [48]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2" [51]

3/8" [10]

1’-9" Monogram

Paint edge of alum. & acrylic Black

15/16" [24]

285, Facility Signs Engineering Drawings

5/32" [4]

Extruded alum. retainer #GE-118

5/16" [8]

0

1 7/8" [48]

3

Inches

3/16" alum. stud welded to letter, w/ elastic stop-nut & wide flat washer (place as req’d. for adequate attachment, min. (2) per letter)

1 1/2

Extruded alum. retainer clip #GE-119

#10 pan hd. self-tapping screw @ 18" c/c

Alum. angle: 1 1/2 x 1 1/2 x 1/8 x 1/2" lg. (weld to one retainer, rivet to the other) typ. each corner

.315 x 1/2" Lexan lug cont. (cement to face)

Alum. angle: 1 1/2 x 1 1/2 x 1/2 x 1/8" thick (weld to one retainer, (2) flat hd. screws other retainer) typ. each corner

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3"=1’-0"

0

3

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

Letter Attachment Detail

3/8" dia. hole, fill w/ silicone

.250 alum. letter

.315 Lexan face

1/4" [6]

Scale: 3"=1’-0"

Section 8

.315 clear Lexan face w/ White translucent film on 2nd surface

#4 x 1/2"- type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

2" [51]

GE Identity Program 15/16" [24] 5/32" [4]

Pole Sign, C-7 Face Fabrication Details

285.07.30

Pole Sign, C-7 Face Fabrication Details 285.07.30

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

7" [178]

g

1’-9" [533] 7" min. [178]

7" min. [178]

7’-1 1/2" [2172] 7’-1 1/2" [2172]

Scale: 3/16"=1’-0"

0

24

36

48

Inches

7" min. [178]

7" min. [178]

GE Superabrasives

g

1’-9" [533]

7’-1 1/2" [2172]

Medium Length Name

GE Aircraft Engines

g

1’-9" [533]

7" [178]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

7" [178]

7" [178]

7’-1 1/2" [2172]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

Face Layouts

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

g

1’-9" [533]

7’-1 1/2" [2172]

Short Name

GE Silicones

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Laser Line: GE color Laser Red translucent (typ.)

Graphics: Black opaque, matte finish (typ.)

Face background: White translucent (typ.)

Monogram letters/curlicues: White translucent (typ.)

Monogram field: Black opaque, matte finish (typ.)

7" [178]

7" [178] 1’-9" [533] 1’-9" [533]

7’-1 1/2" [2172]

11 3/8" typ. [289] 8 1/2" typ. [216]

10 1/4" [260] 7 11/16" [195] 6 3/4" [171] 5/8" [16]

8 1/2" [216] 6 3/8" [162]

5/8" [16] 1’-5 15/16" [456] 9" typ. [229] 3 3/8" typ. [86]

7" [178] 9" 1’-9" [229] [533] 7 3/8" [187]

4 1/4" [108] 11 3/8" [289] 3 3/16" [81]

7’-1 1/2" [2172] 7’-1 1/2" [2172]

1’-9" [533] 10" 5/8" [254] [16] 7" [178] 1’-9" [533] 1’-5" [432]

285, Facility Signs Engineering Drawings

5/8" [16]

GE Identity Program

~

1’-1 5/16" [338]

Pole Sign, C-7 Sample Face Layouts

285.07.31

Pole Sign, C-7 Sample Face Layouts 285.07.31

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See sheet 03 for foundation details

Finished Grade

Laser Line: GE color Laser Red translucent

Face background: GE color G 02 C Grey opaque, matte finish

Graphics: Black opaque, matte finish

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

24

48

72

96

See sheet 10 for face fab. details

Dynamic Monogram letters/curlicues: GE color G 02 C PMS-421C Grey opaque, matte finish

See Anchor Bolt Detail, sheet 02

1’-4" [406]

Base: GE color G 03 C Grey, matte finish See sheet 08 for details

Disconnect switch

Filler: GE color G 02 C Grey, matte finish

Faces hinged for service

2. If this sign is used as a single-faced sign, construct as detailed and eliminate lighting and graphics at one face. (Face to be GE color G 02 C opaque)

Lighting Notes 1. This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction shall be identical to what is detailed except internal illumination will be eliminated.

Electrical information given is for double-faced sign. Requirements for single-faced sign will be reduced accordingly.

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side Elevation

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/8"=1’-0"

0

Front Elevation

10’-9" [3277]

Rigid electrical conduit from bldg.

c

g GE Silicones

Dynamic Monogram field: GE color GE 05 C Grey opaque, matte finish

2" [51]

18’-9" [5715]

1/2" [13]

See sheet 04 for signbox fabrication details

External Lighting Fixtures: (4) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 6.48 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (10) GE F48T12 DL/HO Ballasts: (2) 2-Lamp & (2) 3-Lamp Transformers: (1) 7500 Volt/60mA npf Amperage: 11.25 amps Circuits: (1) 20A/120V

7’-6" [2286]

285, Facility Signs Engineering Drawings 2’-10" [864]

GE Identity Program 10’-6" [3200] mounting height

Ground Sign, G-11 Sign Elevation & Installation Drawing

285.09.01

Ground Sign, G-11 Sign Elevation & Installation Drawing 285.09.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

10’-9" [3277] (+/- 1’-0")

Scale: 1/8"=1’-0"

24 48

72

96

4" [102]

3" [76]

Scale: 1"=1’-0"

0

3

9

12

Inches

TS: 5 x 5 x 3/8 column

projection grout

5" [127] 2" [51]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

6

Anchor Bolt Detail

3" [76]

Ground Sign, G-11 Installation & Lighting Details

10" [254]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1" dia. anchor bolt w/ double hex. nuts & washers (8 req’d. total)

Top of foundation

(2) 1" dia. hex. nuts & flat washers (8 req’d. per column)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Inches

4’-0" [1219]

Exterior Lighting Plan

4’-0" [1219]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Direct burial light fixture w/ 150 watt metal halide bulb (2 req’d. each side)

Sign face

Sign face (double-faced sign)

Direct burial light fixture w/ 150 watt metal halide bulb (2 req’d. each side) 5’-0" [1524] 5’-0" [1524]

285, Facility Signs Engineering Drawings

1’-0" [305]

GE Identity Program

285.09.02

Ground Sign, G-11 Installation & Lighting Details 285.09.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

48

Inches

0

12

24

36

48

4 1/2" [114] typ. See Anchor Bolt Detail Sheet 02 (typ.)

TS: 5 x 5 x 3/8 column (typ.)

8’-6" [2591]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

36

2" [51] typ.

4’-0" [1219]

2’-0" [610]

Rigid electical conduit from bldg.

Finished Grade

24

Front Elevation

4’-0" [1219]

12

10’-9" [3277]

0

1" dia. anchor bolt location (typ.)

Electrical conduit stub-out location

Scale: 3/16"=1’-0"

Plan

7" [178]

4’-0" [1219]

1’-6" [457]

4’-3" [1295] 4’-3" [1295]

10’-9" [3277]

8"

2’-0" [610]

[203]

285, Facility Signs Engineering Drawings 3’-0" [914]

GE Identity Program Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities Horizontal Slab Foundations: Concrete: 7.6 cu. yds.

Ground Sign, G-11 Foundation Drawing

285.09.03

Ground Sign, G-11 Foundation Drawing 285.09.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5 07

3’-10 1/4" [1175]

4’-0" [1219]

2

3

24

12

Rigid electrical conduit from building

0

48

Inches

36

48

Inches

07

6

1

opp. hand

Fluorescent lighting unit

Alum. angle: 2 x 2 x 3/16 corner reinforcing (typ. ea. corner)

Extruded alum. filler #GE-111

1/2" dia. eyebolt for lifting (typ.) Replace w/ 1/2" dia. rd. hd. mach. screw after installation

Face prop rod ass’y. (typ.)

Face bumper pipe w/ crutch tips each end. typ. (Weld to column)

07

4

04

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

TS: 5 x 5 x 3/8 column

C3 x 5 for mounting transformer box

4’-0" [1219]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

.125 fabricated alum. support bracket (typ. each end)

2 05

(1) 7500 volt/ 60 mA npf transformer in alum. trans. box

C3 x 5 for mounting ballast boxes

4" x 4" junction box

Scale: 1/4"=1’-0"

36

(1) 2-lamp & (1) 3-lamp ballast in alum. ballast box & cover (typ. 2 places)

10’-9" [3277]

2" x 4" junction box

06

12

18’-9" [5715]

0

Front View

05

Scale: 1/4"=1’-0"

Section 1

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 1 x 10 x 13 w/(4) 1 1/4" dia. holes

Bell flush disconnect switch #216-20-OG w/ Bell box #250

07

4

6" [152]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

15 mm clear red neon tubing (Verify that neon will illuminate entire length of Laser Line) Neon tube length & position varies based on face layout

1/2" dia. flex liquid-tight conduit typ.

(5) GE F48T12 DL/HO lamps (typ. 2 places)

Angle: 1 1/2 x 1 1/2 x 3/16 (typical top & bottom)

Fluorescent lighting unit

3’-4" [1016]

6 1/4" [159]

4" [102]

4" [102]

1’-3 1/4" [387]

1’-4" [406]

Fluorescent lighting unit

3’-0" [914]

Neon lighting unit

7’-6" [2286]

285, Facility Signs Engineering Drawings

3’-6" [1067]

GE Identity Program 8" [203]

Ground Sign, G-11 Signbox Fabrication Drawing

285.09.04

Ground Sign, G-11 Signbox Fabrication Drawing 285.09.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1 1/2"=1’-0"

Section 2

8" [203]

0

3

3/16

6

Inches

typ.

8" [203]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. w/(1) 3/8" dia. hex. bolt, nut & lockwasher

Cap plate: 1/4 x 5 x 10

3/16" x 1/2" neoprene gasket, cont.

.090 x 3/4 x 3/4 x 3" lg. alum. hinge (@ 3’-0" c/c) Rivet to filler, weld to retainer

1/2" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3" [76]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.090 Alum. fluorescent lighting baffle unit (Paint inside white)

3/16" x 3/4" cont. neoprene gasket (typ.)

Angle: 1 1/2 x 1 1/2 x 3/16 lighting baffle suport

Extruded alum. retainer #GE-112

1/2" dia. rd. hd. mach. screw, nut & lockwasher (4 req’d. per column) gage = 7"

1’-4" [406]

Ground Sign, G-11 Signbox Fabrication Details

285.09.05

Ground Sign, G-11 Signbox Fabrication Details 285.09.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1’-3 1/4" [387] varies

3 1/4" [83]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1" [25]

Scale: 1 1/2"=1’-0"

Section 3

2 3/4" [70]

1/8

0

3

3/16

6

1" [25]

Inches

Ground Sign, G-11 Signbox Fabrication Details

TS: 5 x 5 x 3/8 column

1/2" dia. flex. liquid tight conduit

PK housing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Extruded alum. filler #GE-111

.090 x 1 x 1 15/16 Alum. reveal closure cont. (Attach to retainer w/ pop rivets @ 18" c/c)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

7 1/2" [190]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

5/8" dia. hex. hd. bolt, nut & lockwasher (4) req’d. per column Gage = 7 1/2"

Plate: 1/2 x 9 1/2 x 9 1/2

Provide 1/4" dia. weep holes as req’d.

.315 Lexan face: See sheet 10 for details

Angle: 1 1/2 x 1 1/2 x 3/16 x 8" lg. w/ (1) 3/8" dia. hex. bolt, nut & lockwasher in 7/16" x 3/4" slot (typ. n.s. & f.s.)

1 1/4" tube stand as req’d.

(1) row of 15mm clear red neon tubing 5/8" [16] 2" [51] 5/8" [16]

.090 Alum. neon baffle unit w/ end closures (Pop rivet to 1 1/2 x 1 1/2 x 3/16 x 8’-0" long back-up angle) Paint inside baffle white

2" [51]

GE Identity Program

285.09.06

Ground Sign, G-11 Signbox Fabrication Details 285.09.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Scale: 1 1/2"=1’-0"

3

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

Extruded alum. filler #GE-111

0 6

Inches

.315 Lexan face

0

3

6

4" [102]

10" [254]

9

12

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1"=1’-0"

Section 6

TS: 5 x 5 x 3/8 column

Base plate: 1 x 10 x 13 w/ (4) 1 1/4" dia. holes

3" [76]

3" [76]

3/16" x 3/4" neoprene gasket, cont. all around

1/2" dia. x 1 1/2" short nipple w/ locknuts

1/2" dia. flex. conduit

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to column) typ. @ t & b of lighting baffle

1 1/4" x 2" alum. raceway & cover Kulka socket #582-G

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3

.090 alum. light baffle unit

Kulka socket #583-G

(5) GE F48T12 DL/HO lamps

Alum. angle: 2 x 2 x 3/16 x 5" lg. corner reinf. (Weld to filler)

0

3’-10 1/4" [1175]

.125 Alum. back w/ #10 s.s. sht. metal screws 12" c/c (hinged for service)

Section 4

2" [51]

Alum. angle: 2 x 2 x 3/16 x 2" lg. corner reinf. (Weld to filler) 2-req’d. @ each corner

.315 Lexan face

Section 5

Angle: 1 1/2 x 1 1/2 x 3/16 x 4’-4" lg. w/ (2) 3/8" dia. hex. bolts, nuts & lockwashers (Pop rivet to baffle unit) typ. t & b 5 1/4" [133]

Alum. angle: 3 x 3 x 3/16 x 3" lg. (Weld to filler) typ. @ t & b of lighting baffle

Extruded Alum. filler #GE-111

1 1/4" [32]

4’-2 1/4" [1276]

9" [229]

4" [102]

2" [51] 1’-1" [330]

285, Facility Signs Engineering Drawings

2" [51]

GE Identity Program 4" [102]

Ground Sign, G-11 Signbox Fabrication Details

285.09.07

Ground Sign, G-11 Signbox Fabrication Details 285.09.07

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings Scale: 1/4"=1’-0"

0

cont.

7

24

08

Inches

3’-3" [991]

3

36

48

Inches

5’-4 1/2" [1638]

1 1/2

G

1/8

09

8

9 09

1 1/4" [32]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

4’-0" [1219]

as req’d.

.125 x 1 1/2 Alum. bar cont.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

12

Covering shop splice

4’-3" [1295]

10’-9" [3277]

18’-9" [5715]

Front View

5’-4 1/2" [1638]

3’-3" [991]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

TS: 5 x 5 x 3/8 column

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Alum. channel: 2 x 1 x 1/8 cont. (typ. t & b, ns & fs)

.125 Alum. base covering

Angle: 2 x 2 x 3/16 support (typ.)

Angle: 2 x 2 x 3/16 brace (typ.)

Sign box

4’-0" [1219]

Scale: 3"=1’-0"

Section 7

.125 Alum. base covering

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

(1) 1/4" dia. bolt, nut & lockwasher

2" [51] reveal 2’-9 1/2" [851]

GE Identity Program 6 1/2" [165]

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg.

Ground Sign, G-11 Base Covering Drawing

285.09.08

Ground Sign, G-11 Base Covering Drawing 285.09.08

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

typ.

Scale: 1 1/2"=1’-0"

Section 8

1/8

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1/4" dia. hex. hd. bolt, nut & lockwasher (typ.)

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg. (typ.)

Fill & grind smooth, cont.

Sign filler

Sign face

3

6

Inches

typ.

3

1/8

6

8" [203] Inches

typ.

1’-4" [406] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 9

.125 Alum. base covering(typ.)

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

Pop rivet @ 12" c/c

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg. w/ (2) 1/4" dia. bolts, nuts & lockwashers

0

Ground Sign, G-11 Base Covering Details

Alum. angle: 1 1/2 x 1 1/2 x 3/16 vertical (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 Alum. base covering(typ.)

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

Alum. angle: 1 1/2 x 3/4 x 1/8 cont. (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1/8

1/8

typ.

#10 flat hd. CSK self-tapping screws @ 18" c/c (typ.) (Remove to hinge face)

TS: 5 x 5 x 3/8 column

2" [51]

285, Facility Signs Engineering Drawings

8" [203]

GE Identity Program

285.09.09

Ground Sign, G-11 Base Covering Details 285.09.09

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 clear Lexan face: Background: GE color G 02 C Grey opaque, matte finish, on 1st surface

Laser Line: Film to match GE color Laser Red translucent applied to 1st surface (Face clear behind Laser Line)

Monogram letters/curlicues: White translucent (face area behind Monogram remains clear)

Monogram field: Black opaque, matte finish

Cement Monogram to face behind opaque area only

11

12 sim.

11

11

8 3/4" [222] .250 flat cut-out alum. letters painted black, matte finish (bolt to face, see Letter Attachment Detail, sheet 11) typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Front View 12

24

36

48

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

11

sim. 12

5/16" [8]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

c

Dynamic Monogram field: GE color G 05 C Grey opaque (Applied to 1st surface), matte finish

11

12

g GE Silicones

11

10

2’-11" [889]

18’-9" [5715] (retainer) 18’-8 3/8" [5699] (face)

Ground Sign, G-11 Face Fabrication Elevation

7’-5 9/16" [2275] (face)

8 3/4" [222] 2’-11" [889] 1’-2 3/4" 1’-1" 1’-5 1/2" [375] [330] [445]

5/32" [4] 7’-6" [2286] (retainer)

5/16" [8]

1" [25]

285, Facility Signs Engineering Drawings

9/32" [7]

GE Identity Program

285.09.10

Ground Sign, G-11 Face Fabrication Elevation 285.09.10

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1 1/2

Scale: Half

0 1 1/2

1/8" [3]

Inches

Inches

3

[3]

face area behind Monogram

3/8" [10]

5/16" [8]

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

Scale: 3"=1’-0"

5/16" [8]

Scale: Half

0

1 1/2

3

Inches

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd.

7/16" [11]

Drill & csk for #10 flat hd. self-tapping screws @ 18"c/c (@ sides only)

Extruded Alum. retainer #GE-112

.315 Lexan lug cont. (cement to face)

#10 pan hd. self-tapping screws @ 18"c/c

Extruded Alum. "T" bar #GE-113

.315 Lexan face

3/4

Section 12

5/16" [8]

1/8" [3] min.

0

Letter Attachment Detail

1/4" [6]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 flat alum. angle: 3 x 3 x 3/4 corner stiffener (Weld one leg to retainer, pop rivet the other) typ. each corner

Extruded Alum. "T" bar #GE-113

#10 pan hd. self-tapping screws @ 18"c/c

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 1/2" lg. corner stiffener (Weld one leg to retainer, pop rivet the other) typ. ea. corner

Extruded Alum. retainer #GE-112

2’-11" [889] Monogram

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 11

5/16" [8]

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 Lexan face

.315 Lexan lug cont. (cement to face)

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd. @ 12" c/c

5/16" [8] 1/8" [3]

Scale: 3"=1’-0"

Section 10

.315 clear Lexan face decorated GE color GE 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 2’-11" dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

Paint edge of alum. & acrylic black

1/8"

[13]

5/16" [8] 1/2"

Opaque Grey face 2’-10 3/4" [883] dia. clear

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

1/16" [2]

285, Facility Signs Engineering Drawings 3/8" [10]

GE Identity Program 3/16" [5]

Ground Sign, G-11 Face Fabrication Details

285.09.11

Ground Sign, G-11 Face Fabrication Details 285.09.11

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-5 1/2" [444]

8 3/4" [222]

Letters: Black (typ.)

18’-9" [5715]

g

2’-11" [889]

Scale: 1/8"=1’-0"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

24

48

8 3/4" [222]

8 3/4" [222]

72

96

c

GE Aircraft Engines

18’-9" [5715]

18’-9" [5715]

c Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

gGE Superabrasives

2’-11" [889]

Medium Length Name

g

2’-11" [889]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

c

GE Electrical Distribution & Control

18’-9" [5715]

Dynamic Monogram letters/curlicues: GE color G 02 C Grey (typ.)

c

Short Name

Dynamic Monogram field: GE color G 05 C Grey (typ.)

g GE Silicones

2’-11" [889]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

2’-11" [889]

8 3/4" [222]

8 3/4" [222]

2’-4 7/16" [722] 1’-0" [305]

1" 1’-1" [25] [330]

8 3/4" [222]

2’-11" [889]

3’-1 1/4" [946]

1" [25]

8 3/4" [222] 8 3/4" [222] 6" 6" [152] [152]

1’-0" [305] 1’-4" 1’-4" 1’-4" [406] [406] [406]

8 3/4" [222] 8 3/4" [222]

8 3/4" [222] 2’-11" [889] 1" [25] 8 3/4" [222] 1’-4" 2’-11" [406] [889]

285, Facility Signs Engineering Drawings 1" [25]

1’-5 1/2" [444] 6 9/16" [167]

GE Identity Program 1’-5 1/2" [444]

Ground Sign, G-11 Sample Face Layouts

285.09.12

Ground Sign, G-11 Sample Face Layouts 285.09.12

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

See sheet 23 for foundation details

Finished Grade

Laser Line: GE color Laser Red translucent

Face background: GE color G 02 C Grey opaque, matte finish

Graphics: Black opaque, matte finish

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

0

12

24

36

48

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

Front Elevation

6’-9" [2057]

Rigid electrical conduit from bldg.

See sheet 30 for face fab. details

See Anchor Bolt Detail, sheet 22

Base: GE color G 03 C Grey, matte finish. See sheet 28 for details

Disconnect switch

Filler: GE color G 02 C Grey matte finish

Faces hinged for service

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side Elevation

1’-4" [406]

2. If this sign is used as a single-faced sign, construct as detailed and eliminate lighting and graphics at one face. (Face to be GE color G 02 C opaque)

Lighting Notes 1. This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction shall be identical to what is detailed except internal illumination will be eliminated.

Electrical information given is for double-faced sign. Requirements for single-faced sign will be reduced accordingly.

Dynamic Monogram letters/curlicues: GE color G 02 C Grey opaque, matte finish

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

c

g GE Silicones

Dynamic Monogram field: GE color GE 05 C Grey opaque, matte finish

1 1/2" [38]

12’-9" [3886]

1/2" [13]

See sheet 24 for signbox fabrication details

5’-1" [1549] 2’-0 1/2" [622]

285, Facility Signs Engineering Drawings 7’-3" [2210] mounting height

GE Identity Program External Lighting Fixtures: (4) CDB-150-DMH-120V-DMH/A Composite Direct Burial Wallwash/Uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 6.48 amps Circuits: (1) 20A/120V

Electrical Information Internal Lamps: (6) GE F36T12 DL/HO Ballasts: (2) 3-Lamp Transformers: (1) 7500 Volt/60mA npf Amperage: 6.75 amps Circuits: (1) 20A/120V

Ground Sign, G-7 Sign Elevation & Installation Drawing

285.09.21

Ground Sign, G-7 Sign Elevation & Installation Drawing 285.09.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3’-0" [914]

6’-9" [2057] (+/- 1’-0")

3’-0" [914]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1/8"=1’-0"

0 48

72

96

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

24

Exterior Lighting Plan

Direct burial light fixture w/ 150 watt metal halide bulb (2-req’d. each side)

Sign face

Sign face (double-faced sign)

Direct burial light fixture w/ 150 watt metal halide bulb (2-req’d. each side) 5’-0" [1524] 5’-0" [1524]

Scale: 1"=1’-0"

0

6

9

Inches

4 1/2" [114]

projection grout

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3

12

TS: 4 x 4 x 3/16 column

Anchor Bolt Detail

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3/4" dia. anchor bolt (8-req’d. total)

Top of foundation

(2) 3/4" dia. hex. nuts & flat washers (8-req’d. per column)

3" 3" 3" [76] [76] [76]

9" [228]

Ground Sign, G-7 Installation & Lighting Details

1 1/2" [38]

285, Facility Signs Engineering Drawings

9" [229]

GE Identity Program

285.09.22

Ground Sign, G-7 Installation & Lighting Details 285.09.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Finished Grade

3/4" dia. anchor bolt location (typ.)

12

0

12

36

48

[76]

See Anchor Bolt Detail Sheet 22 (typ.)

TS: 4 x 4 x 3/16 column (typ.)

8" [203] Inches

24

36

48

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

3"

6’-0" [1829]

Rigid electical conduit from bldg.

24

Front Elevation

3’-0" [914]

0

1’-6" [457] 3’-0" [914]

Electrical conduit stub-out location

6’-9" [2057]

Scale: 3/16"=1’-0"

Plan

6" [152]

3’-0" [914]

1’-6" [457]

3’-0" [914] 3’-0" [914]

6’-9" [2057]

8"

285, Facility Signs Engineering Drawings [203]

GE Identity Program 3’-0" [914]

1’-6" [457]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities Horizontal Slab Foundations: Concrete: 4.0 cu. yds.

Ground Sign, G-7 Foundation Drawing

285.09.23

Ground Sign, G-7 Foundation Drawing 285.09.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

(3) GE F36T12 DL/HO lamps

Angle: 1 1/2 x 1 1/2 x 3/16 (typical top & bottom)

4 1/2" [114]

4 27

Face prop rod ass’y. (typ.)

2’-10 1/4" [870]

2 25

0 12

24

Scale: 3/8"=1’-0"

12

24

Inches

5 27

1

26

3

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face bumper pipe w/ crutch tips each end. typ. (Weld to column)

opp. hand

Fluorescent lighting unit

Alum. angle: 2 x 2 x 3/16 corner reinforcing (typ. ea. corner)

Extruded alum. filler #GE-111

24

TS: 4 x 4 x 3/16 column

C3 x 5 for mounting transformer box

3’-0" [914]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Front View

Rigid electrical conduit from building

.125 fabricated alum. support bracket (typ. each end)

25

2

Inches

(1) 7500 volt/ 60 mA npf transformer in alum. trans. box

2" x 4" junction box

(1) 3-lamp ballast in alum. ballast box & cover (typ.)

1/2" dia. eyebolt for lifting (typ.) Replace w/ 1/2" dia. rd. hd. mach. screw after installation

6’-9" [2057]

12’-9" [3886]

Scale: 3/8"=1’-0"

Section 1

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 3/4 x 9 x 12 w/(4) 7/8" dia. holes

Bell flush disconnect switch #216-20-OG w/ Bell box #250

26

3

5" [127]

3’-0" [914]

Fluorescent lighting unit

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

15 mm clear red neon tubing (Verify that neon will illuminate entire length of Laser Line) Neon tube length & position varies based on face layout

1/2" dia. flex liquid-tight conduit typ.

10 5/8"

2’-3" [686]

5 1/2" [140]

8" 8" [203] [203]

5 1/2" [140]

1’-4" [406]

Fluorescent lighting unit

2’-0" [610]

Neon lighting unit

5’-1" [1549]

285, Facility Signs Engineering Drawings

2’-8 1/2" [826]

GE Identity Program

[270]

Ground Sign, G-7 Signbox Fabrication Drawing

285.09.24

Ground Sign, G-7 Signbox Fabrication Drawing 285.09.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1 1/8"

1" [25]

Scale: 1 1/2"=1’-0"

3

3/16

typ.

8" [203]

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 3/4 x 9 x 12

TS: 4 x 4 x 3/16 column

Extruded alum. filler #GE-111

Plate: 1/2 x 8 x 9 1/2

Alum. base: See sht. 28 for fabrication details

#10 flat hd. CSK self-tapping screws @ 18" c/c (typ.) (Remove to hinge face)

.315 Lexan face: See sheet 30 for details

1/2" dia. flex. liquid tight conduit

PK housing

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. w/(1) 3/8" dia. hex. bolt, nut & lockwasher

Cap plate: 1/4 x 5 x 9

3/16" x 1/2" neoprene gasket, cont.

.090 x 3/4 x 3/4 x 3" lg. alum. hinge (5-req’d. ea. face) Rivet to filler, weld to retainer

1/2" dia. shoulder pattern eyebolt w/ hex. nut for lifting (weld nut inside cap plate)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

7 1/2" [190]

3" [76]

1’-4" [406]

Section 2

[29]

3/16

2 3/4" [70]

8" [203]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1/2" dia. hex. hd. bolt, nut & lockwasher (4) req’d. per column Gage = 6"

Provide 1/4" dia. weep holes as req’d.

.090 x 1 x 1 7/16 Alum. reveal closure cont. (Attach to retainer w/ pop rivets @ 18" c/c)

Angle: 1 1/2 x 1 1/2 x 3/16 x 7" lg. w/ (1) 3/8" dia. hex. bolt, nut & lockwasher in 7/16" x 3/4" slot (typ. n.s. & f.s.)

.090 Alum. neon baffle unit w/ end closures (Pop rivet to 1 1/2 x 1 1/2 x 3/16 x 5’-0" long back-up angle) Paint inside baffle white

(1) row of 15mm clear red neon tubing

1 1/4" tube stand as req’d.

10 5/8" [270] varies

3/16" x 3/4" cont. neoprene gasket (typ.)

.090 Alum. fluorescent lighting baffle unit (Paint inside white)

Angle: 1 1/2 x 1 1/2 x 3/16 lighting baffle suport

Extruded alum. retainer #GE-112

3 1/4" [83]

1/2" dia. rd. hd. mach. screw, nut & lockwasher (4-req’d. per column) gage = 7"

5/8" [16] 2" [51]

285, Facility Signs Engineering Drawings 1 1/2" [38]

GE Identity Program 5/8" [16]

Ground Sign, G-7 Signbox Fabrication Details

285.09.25

Ground Sign, G-7 Signbox Fabrication Details 285.09.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

3" [76] 2" [51]

Scale: 1 1/2"=1’-0"

Section 3 0

6

Inches

(1) 3-lamp ballast, alum. ballast box & cover

1/2" dia. x 1 1/2" short nipple w/ locknuts

Angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to column) typ. @ t & b of lighting baffle

Ground Sign, G-7 Signbox Fabrication Details

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/4" x 2" alum. raceway & cover Kulka socket #582-G

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3

.315 Lexan face

.090 alum. light baffle unit

Kulka socket #583-G

(3) GE F36T12 DL/HO lamps

.125 Alum. back w/ #10 s.s. sht. metal screws 12" c/c (remove for service)

.315 Lexan face

2’-10 1/4" [870]

3’-2 1/4" [972]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/16" x 3/4" neoprene gasket, cont. all around

Angle: 1 1/2 x 1 1/2 x 3/16 x 3’-4" lg. w/ (2) 3/8" dia. hex. bolts, nuts & lockwashers (Pop rivet to baffle unit) typ. t & b

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (Weld to filler) typ. @ t & b of lighting baffle

Extruded Alum. filler #GE-111

5 3/4" [146]

1 1/4" [32]

285, Facility Signs Engineering Drawings 4 1/2" [114]

GE Identity Program

285.09.26

Ground Sign, G-7 Signbox Fabrication Details 285.09.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

0

3

6

6" [152]

9

1 1/2

12

1 1/2" [38]

3

Inches

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

9" [229]

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1"=1’-0"

Section 5

TS: 4 x 4 x 3/16 column

Base plate: 3/4 x 9 x 12 w/ (4) 7/8" dia. holes

1 1/2" [38]

Scale: 3"=1’-0"

Section 4

Extruded alum. filler #GE-111

Alum. angle: 2 x 2 x 3/16 x 5" lg. corner reinf. (Weld to filler)

Alum. angle: 2 x 2 x 3/16 x 2" lg. corner reinf. (Weld to filler) 2-req’d. @ each corner

8" [203]

2" [51] 12" [305]

285, Facility Signs Engineering Drawings 2" [51]

GE Identity Program Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Ground Sign, G-7 Signbox Fabrication Details

285.09.27

Ground Sign, G-7 Signbox Fabrication Details 285.09.27

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

4’-0" [1219]

0

cont.

[114]

12

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

3’-4 1/2" [1029]

28

6

8 29

1 1/2" [38] reveal Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

7 29

Covering shop splice

Inches

as req’d.

4’-0" [1219]

3

1/8

.125 x 1 1/2 Alum. bar cont.

(1) 1/4" dia. bolt, nut & lockwasher

6’-9" [2057]

Front View Scale: 3/8"=1’-0"

G 1 1/2

12’-9" [3886]

4 1/2" 3’-4 1/2" [1029]

Scale: 3"=1’-0"

Section 6

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

TS: 4 x 4 x 3/16 column

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Alum. channel: 2 x 1 x 1/8 cont. (typ. t & b, ns & fs)

.125 Alum. base covering

Angle: 2 x 2 x 3/16 support (typ.)

Angle: 2 x 2 x 3/16 brace (typ.)

Sign box

1/8

.125 Alum. base covering

as req’d.

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

Alum. angle: 1 1/2 x 1 1/2 x 3/16 vert.

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg.

[32] 1 1/4"

285, Facility Signs Engineering Drawings

2’-0" [610]

GE Identity Program 7" [178]

Ground Sign, G-7 Base Covering Drawing

285.09.28

Ground Sign, G-7 Base Covering Drawing 285.09.28

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1/8

[29]

typ.

Scale: 1 1/2"=1’-0"

Section 7

1 1/8"

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1/4" dia. hex. hd. bolt, nut & lockwasher (typ.)

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg. (typ.)

Fill & grind smooth, cont.

Sign retainer

Sign face

3

6

Inches

typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1/8

3

1/8

6

8" [203] Inches

typ.

1’-4" [406] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 8

.125 Alum. base covering (typ.)

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

Pop rivet @ 12" c/c

Angle: 2 x 2 x 3/16 x 1’-3 1/2" lg. w/ (2) 1/4" dia. bolts, nuts & lockwashers

0

Ground Sign, G-7 Base Covering Details

Alum. angle: 1 1/2 x 1 1/2 x 3/16 vertical (typ.)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 Alum. base covering (typ.)

Alum. channel: 2 x 1 x 1/8 cont. (typ.)

Alum. angle: 1 1/2 x 3/4 x 1/8 cont. (typ.)

1/8

typ.

#10 flat hd. CSK self-tapping screws @ 18" c/c (typ.) (Remove to hinge face)

TS: 4 x 4 x 3/16 column

1 1/2" [38]

285, Facility Signs Engineering Drawings

8" [203]

GE Identity Program

285.09.29

Ground Sign, G-7 Base Covering Details 285.09.29

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

6" [152]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 clear Lexan face: Background: GE color G 02 C Grey opaque Matte finish on 1st surface

Laser Line : Film to match GE color Laser Red translucent applied to 1st surface (face clear behind Laser Line)

Monogram letters/curlicues: White translucent (face area behind Monogram remains clear)

Monogram field: Black opaque, matte finish

Cement Monogram to face behind opaque area only

31

11 sim.

31

10

6" [152] .250 flat cut-out alum. letters painted black, matte finish (bolt to face, See Letter Attachment Detail sheet 31) typ.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

Front View 12

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

31

sim. 11

9/32" [7]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Dynamic Monogram (letters/curlicues): GE color G 02 C Grey opaque, matte finish

c

Dynamic Monogram (field): GE color G 05 C Grey opaque (Applied to 1st surface), matte finish

31

11

g GE Silicones

31

9

2’-0" [609]

12’-8 7/16" [3872] (face)

12’-9" [3886] (retainer)

5’-0 9/16" [1538] (face)

Ground Sign, G-7 Face Fabrication Elevation

3/16" [5] 5’-1" [1549] (retainer)

9/32" [7]

3/4" [19]

2’-0" [609] 1’-0" [305] 9 1/4" 9" [235] [229]

285, Facility Signs Engineering Drawings

1/4" [6]

GE Identity Program

285.09.30

Ground Sign, G-7 Face Fabrication Elevation 285.09.30

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1 1/2

Scale: Half

0 1 1/2

1/8" [3]

Inches

Inches

3

[3]

face area behind Monogram

1/4" [6]

5/16" [8]

.250 alum. letter

.315 clear Lexan face

3/16" dia. alum. stud welded to letter, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment, min. 2 per letter)

3/8" dia. hole filled w/ silicone

Scale: 3"=1’-0"

5/16" [8]

Scale: Half

0

1 1/2

3

Inches

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd.

7/16" [11]

Drill & csk for #10 flat hd. self-tapping screws @ 18"c/c (@ sides only)

Extruded Alum. retainer #GE-112

.315 Lexan lug cont. (cement to face)

#10 pan hd. self-tapping screws @ 18"c/c

Extruded Alum. "T" bar #GE-113

.315 Lexan face

3/4

Section 11

5/16" [8]

1/8" [3] min.

0

Letter Attachment Detail

1/4" [6]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 flat alum. angle: 3 x 3 x 3/4 corner stiffener (Weld one leg to retainer, pop rivet the other) typ. each corner

Extruded Alum. "T" bar #GE-113

#10 pan hd. self-tapping screws @ 18"c/c

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 1/2" lg. corner stiffener (Weld one leg to retainer, pop rivet the other) typ. ea. corner

Extruded Alum. retainer #GE-112

2’-0" [610] Monogram

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

Section 10

5/16" [8]

0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 Lexan face

.315 Lexan lug cont. (cement to face)

#6 x 1/2" Type BF thd. cutting screws w/ flat csk. hd. @ 12" c/c

5/16" [8] 1/8" [3]

Scale: 3"=1’-0"

Section 9

.315 clear Lexan face decorated GE color G 02 C grey opaque on 1st surface

.125 W7328 white acrylic x 2’-0 dia. (cement to Lexan face behind opaque areas only)

.500 clear acrylic Monogram letters/ curlicues w/ polished edges (cement to white acrylic)

.090 alum. overlay @ Monogram field painted black, matte finish

Paint edge of alum. & acrylic black

1/8"

[13]

5/16" [8] 1/2"

Opaque Grey face 1’-11 3/4" [603] dia. clear

3/16" dia. alum. stud welded to alum. overlay, attach w/ washer & elastic stop-nut (space as req’d. to maintain secure attachment of alum. to acrylic)

3/32" [2]

285, Facility Signs Engineering Drawings 1/4" [6]

GE Identity Program 5/32" [4]

Ground Sign, G-7 Face Fabrication Details

285.09.31

Ground Sign, G-7 Face Fabrication Details 285.09.31

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

6" [152]

Letters: Black (typ.)

12’-9" [3886]

g

2’-0" [609]

0

12

24

6" [152]

36

48

6" [152]

c

GE Aircraft Engines

12’-9" [3886]

12’-9" [3886]

c Inches

4 1/2" [114]

1’-0" 1’-0" 1’-0" [305] [305][305]

6" [152]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-Word Name

gGE Superabrasives

2’-0" [609]

Medium Length Name

g

2’-0" [609]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 3/16"=1’-0"

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

Face Layouts

c

GE Electrical Distribution & Control

12’-9" [3886]

Dynamic Monogram letters/curlicues: GE color G 02 C Grey (typ.)

c

Short Name

Dynamic Monogram field: GE color G 05 C Grey (typ.)

g GE Silicones

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face background: GE color G 02 C Grey (typ.)

Laser Line: GE color Laser Red (typ.)

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

1’-0" [305]

6" [152]

2’-0" [609]

2’-0" [609]

6" [152] 6" 4" 4" [102] [102] [152]

6" [152]

8 1/4" [210]

3/4" 9" [19] [229]

6" [152]

2’-0" [609]

2’-0 3/4" [629]

3/4" [19]

8" [203] 11" 11" 11" [279] [279] [279]

6" [152] 2’-0" [609] 1’-7 1/2" [495] 3/4" [19] 6" [152] 11" 2’-0" [279] [609]

285, Facility Signs Engineering Drawings 3/4" [19]

GE Identity Program 6" [152]

Ground Sign, G-7 Sample Face Layouts

285.09.32

Ground Sign, G-7 Sample Face Layouts 285.09.32

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

g

~ ~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

12

24

Inches

1’-4" [406]

Reveal: GE color G 03 C Grey

Disconnect switch

Filler: GE color G 02 C Grey, matte finish

1" [25]

External Lighting Fixtures: (4) CDB-150-DMH120V-DMH/A Composite direct burial wallwash/uplight for use with the following GE lamp: MQI/150/T7/43 Amperage: 6.48 amps Circuits: (1) 20A/120V

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Electrical information given is for double-faced sign. Requirements at single-faced sign will be reduced accordingly.

Electrical Information Internal Lamps: (6) GE F36T12 DL/HO Ballasts: (2) 3-lamp Transformers: (1) 7500 Volt/60mA npf Amperage: 6.75 amps Circuits: (1) 20A/120V

Side Elevation

6’-0" [1829] mount. height

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

2. If this sign is used as a single-faced sign, construct as detailed and eliminate lighting and graphics at one face. (Face to be GE color G 02 C opaque).

Scale: 3/8"=1’-0"

0

Front Elevation

c

GE Silicones

Dynamic Monogram letters/ curlicues: GE color G 02 C opaque, matte finish

Dynamic Monogram field: GE color G 05 C Grey opaque, matte finish

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1. This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction shall be identical to what is detailed except internal illumination will be eliminated.

Lighting Information

Rigid electrical conduit from building

See Anchor Bolt Detail, sheet 42

See sheet 43 for foundation details

Finished grade

Base: GE color G 03 C Grey, see sheet 48 for details

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

See sheet 50 for face fabrication details

Background: GE color G 02 C Grey opaque, matte finish

Monogram letters/curlicuesWhite translucent

Monogram field: Black opaque, matte finish

Signbox: see sheet 44 for details

Faces hinged for service

~

10’-0" [3048]

4’-0" [1219] 1’-11" [584]

GE Identity Program 1/2" [13]

Ground Sign, G-6 Sign Elevation & Installation Drawing

285.09.41

Ground Sign, G-6 Sign Elevation & Installation Drawing 285.09.41

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5’-0" [1524] + 1’-0" -

2’-6" [762]

0 12

24

36

48

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/16"=1’-0"

Exterior Lighting Plan

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Direct burial light fixture w/ 150 watt metal halide bulb

Signface

Signface (dbl. faced sign)

Direct burial light fixture w/ 150 watt metal halide bulb (@ dbl. faced sign)

2’-6" [762]

5’-0" [1524] min. 5’-0" [1524] min.

285, Facility Signs Engineering Drawings 5" [127]

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

3

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Anchor Bolt Detail

3/4" dia. anchor bolt w/ dbl. heavy hex nuts & washers (4req’d. per column, 8 total)

Top of footing

TS: 3 x 3 x 1/4 column

2" [51]

1 1/2" [38]

Ground Sign, G-6 Installation & Lighting Details

4 1/2" [114] projection 9" [229]

GE Identity Program

285.09.42

Ground Sign, G-6 Installation & Lighting Details 285.09.42

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 7’-6" [2286]

2’-6" [762]

0 12

24

1’-6" [457]

6" [152]

0

5’-0" [1524]

Scale: 3/8"=1’-0"

Plan

2’-6" [762]

1’-3" [381]

Concrete: 2.8 cu. yds.

12

24

2" [51]

Inches

5" [127]

9" [229]

2’-6" [762]

2" [51]

1’-3" [381]

5’-0" [1524]

2’-6" [762] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Estimated Quantities

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Electrical conduit stub-out location

3/4" dia. anchor bolt location (typ.)

Inches

2’-6" [762]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

Front Elevation

2’-6" [762]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Rigid electrical conduit from building

See Anchor Bolt Detail, sheet 42 (typ.)

Coat columns below grade & anchor bolts w/ waterproofing material

8" [203] 3’-0" [914]

Finished grade

5’-0" [1524]

2" [51] 2" [51]

GE Identity Program 7" [178] 11" [279]

Ground Sign, G-6 Foundation Drawing

285.09.43

Ground Sign, G-6 Foundation Drawing 285.09.43

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 3 7/8" [98]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

15mm clear red neon tubing (verify that neon will illuminate entire length of Laser Line) neon tube length & position varies based on face layout (typ. @ both faces)

.125 fabricated alum. support bracket (typ.)

Bell flush disconnect switch #21620-OG w/ Bell box #250

1/2" dia. flex liquid tight conduit (typ.)

L: 1 1/2 x 1 1/2 x 3/16 (typ. t & b)

(3) GE F36T12 DL/HO lamps per unit, (2) units req’d.

1’-10 1/2" [572]

2 1/4" [57]

Alum. angle: 2 x 2 x 3/16 corner reinforcing (typ. each corner)

Extruded alum. filler #GE-111

3 3/4" [95]

7 1/2" 7 1/2" [191] [191]

3 3/4" [95]

Neon lighting unit

4

2 45

Scale: 1/2"=1’-0"

0

6

12

18

24

47

5

2

Inches

45

2’-6" [762]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Front View

Rigid electrical conduit from building

2" x 4" junction box

4" x 4" junction box & cover

7500V/60mA n.p.f. transformer in alum. transformer box

46

3

(1) 3-lamp ballast in alum. ballast box (typ.)

5’-0" [1524]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

47

2’-10 1/4" [870]

2’-6" [762]

10’-0" [3048]

Section 1

9 15/32" [240]

Fluorescent lighting unit

~

GE Identity Program 1

Fluorescent lighting unit

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Base plate: 5/8 x 9 x 11 (typ.)

TS: 3 x 3 x 1/4 column (typ.)

Face prop rod assembly (typ.)

C 3 x 5 for mounting transformer box

Face bumper: pipe w/ crutch tips each end, weld to column

opp. hand

46

3

44

1/2" dia. eyebolt for lifting (typ.) replace w/ 1/2" dia. rd. hd. mach. screw after installation

Fluorescent lighting unit

Ground Sign, G-6 Signbox Fabrication Drawing

285.09.44

Ground Sign, G-6 Signbox Fabrication Drawing 285.09.44

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1" [25]

Scale: 1 1/2"=1’-0"

Section 2

2 3/4" [70]

8" [203]

0

3

8" [203]

6

Inches

Base plate: 5/8 x 9 x 11

TS: 3 x 3 x 1/4 column

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. base: see sheet 48 for fabrication details

#10 flat hd. csk. thd. cutting screws @ 18" c/c (typ.) remove to hinge face

L: 1 1/2 x 1 1/2 x 3/16 x 7" lg. w/ 3/8" hex bolt, nut & washer in 7/16" x 3/4" slot (typ. ns & fs)

1/2" dia. flex liquid tight conduit

PK housing

.315 Lexan face: see sheet 50 for details (typ.)

L: 1 1/2 x 1 1/2 x 3/16 x 3" lg. w/ 3/8" dia. hex bolt, nut & washer

Cap plate: 1/4 x 5 x 11

3/16" x 1/2" neoprene gasket, cont.

Extruded alum. retainer #GE-112

.090 x 3/4 x 3/4 x 3" lg. alum. hinge (rivet to filler, weld to retainer) 4 req’d. each face

1/2" dia. shoulder pattern eyebolt w/ hex nut for lifting (weld nut inside cap plate)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

7 1/2" [191]

3" [76]

1’-4" [406]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Plate: 3/8 x 8 x 9 1/2

1/2" dia. hex hd. bolt, nut & washer (4 req’d. per column) gage = 6"

Provide 1/4" dia. weep holes as req’d.

.090 x 1 x 31/32 alum. reveal closure, cont. (attach to retainer w/ rivets @ 18" c/c)

Extruded alum. filler #GE-111

(1) row of 15mm clear red neon tubing on 1 1/4" tube stand as req’d.

Center line of film Laser Line & neon

3 1/4" [83]

.090 alum. neon baffle unit w/ end closures (rivet to L: 1 1/2 x 1 1/2 x 3/16 x 5’-0" lg. back-up) paint inside of baffle White

.090 alum. fluorescent lighting baffle unit (paint inside White)

3/16" x 3/4" neoprene gasket, cont. (typ.)

L: 1 1/2 x 1 1/2 x 3/16 lighting baffle support

1/2" dia. rd. hd. mach. screw, nut & washer (4-req’d. per column) ga=8"

2" [51]

285, Facility Signs Engineering Drawings 9 15/32" [241] varies

GE Identity Program 1" [25]

Ground Sign, G-6 Signbox Fabrication Details

285.09.45

Ground Sign, G-6 Signbox Fabrication Details 285.09.45

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

3

6

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.090 alum. light baffle unit

1/2" dia. x 1 1/2" short nipple w/ locknuts

3-lamp ballast in alum. ballast box

L: 1 1/2 x 1 1/2 x 3/16 x 2’-8" lg. w/ (2) 3/8" dia. hex bolts, nuts & washers (rivet to baffle unit) typ. t&b

.125 alum. back w/ #10 s.s. sht. metal screws @ 12" c/c (remove for service)

L: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (weld to column) typ. t & b of lighting unit

Ground Sign, G-6 Signbox Fabrication Details

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Kulka socket #582-G

1 3/8" [35]

(3) GE F36T12 DL/HO lamps

Section 3

2’-10 1/4" [870]

3’-1" [940]

1 1/4" x 2" alum. raceway & cover (typ.)

1 3/8" [35]

2 1/2" [64]

3/16" x 3/4" neoprene gasket

.315 Lexan face (typ.)

6 1/4" [159]

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 3" lg. (weld to filler) typ. t & b of lighting unit

Kulka socket #583-G

Extruded alum. filler #GE-111

#10 flat hd. csk. thd. cutting screw @ 18" c/c (typ.)

1 3/4" [44]

285, Facility Signs Engineering Drawings 4 1/2" [114]

GE Identity Program

285.09.46

Ground Sign, G-6 Signbox Fabrication Details 285.09.46

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

0 3

6

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 4

Alum. angle: 2 x 2 x 3/16 x 2" lg. corner reinforcing (weld to filler) 2-req’d. @ each corner

Extruded alum. filler #GE-111

Alum. angle: 2 x 2 x 3/16 x 5" lg. corner reinforcing (weld to filler)

Scale: 1 1/2"=1’-0"

Section 5

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

TS: 3 x 3 x 1/4 column

Base plate: 5/8 x 9 x 11 w/ (4) 7/8" dia. holes

2" [51]

3

2" [51]

6

Inches

11" [279] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

5" [127]

9" [229]

Ground Sign, G-6 Signbox Fabrication Details

2" [51] 7" [178]

285, Facility Signs Engineering Drawings

2" [51]

GE Identity Program

285.09.47

Ground Sign, G-6 Signbox Fabrication Details 285.09.47

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 3 x 3 x 1/4 column (typ.)

.125 alum. base cover: paint GE color G 03 C Grey, matte finish

G

0

Scale: 1 1/2"=1’-0"

0

12

3

24

6

7 49

8 49

as req’d.

3/4" [19]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.125 x 1 1/2 cont. alum. bar

Inches

1/8

Inches

Covering shop splice

2’-6" [762]

2’-6" [762]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Section 6

.125 alum. base covering

(1) 1/4" dia. bolt, nut & washer

cont.

Scale: 3/8"=1’-0"

Front View

Alum. channel: 2 x 1 x 1/8

L: 1 1/2 x 1 1/2 x 3/16 brace

6 48

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. channel: 2 x 1 x 1/8, cont. t & b, ns & fs

L: 1 1/2 x 1 1/2 x 3/16 brace (typ.)

Alum angle: 1 1/2 x 1 1/2 x 3/16 vert. (typ.)

L: 1 1/2 x 1 1/2 x 3/16 support (typ.)

2’-6" [762]

5’-0" [1524]

1" reveal [25] 1’-10 1/2" [572]

Signbox

2’-6" [762]

~

GE Identity Program 7" [178]

10’-0" [3048]

Ground Sign, G-6 Base Covering Drawing

285.09.48

Ground Sign, G-6 Base Covering Drawing 285.09.48

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

Scale: 1 1/2"=1’-0"

Section 7

1/8

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1/4" dia. hex bolt, nut & washer (typ.)

L: 1 1/2 x 1 1/2 x 3/16 x 1’-3 1/2" (typ.)

.125 alum. base covering (typ.)

Fill & grind smooth, cont.

Sign face

3

1/8

6

Inches

typ. .125 alum. cover

1/8

0

3

1" [25]

6

Inches

1’-4" [406] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 8

Alum. channel: 2 x 1 x 1/8 typ.

L: 1 1/2 x 1 1/2 x 3/16 w/ (2) 1/4" dia. bolts, nuts & washers

Rivet @ 12" c/c

Alum. angle: 1 1/2 x 1 1/2 x 3/16 vert. (typ.) typ.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Alum. angle: 1 x 3/4 x 1/8, cont. (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

typ.

Alum. channel: 2 x 1 x 1/8, cont. (typ.)

1/8

typ.

Extruded alum. filler #GE-111 1" [25]

TS: 3 x 3 x 1/4 column

Ground Sign, G-6 Base Covering Details

8" [203] 8" [203]

GE Identity Program

285.09.49

Ground Sign, G-6 Base Covering Details 285.09.49

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

similar

51

11

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Laser Line: Film to match GE color Laser Red translucent applied to 1st surface (face clear behind Laser Line)

.250 flat cut-out alum. letters painted Black, matte finish (bolt to face, see Letter Attachment Detail, sheet 51) typ.

.315 clear Lexan face backgroundGE color G 02 C Grey opaque, matte finish decorated on 1st surface

Monogram letters/curlicues: White translucent (face is clear behind Monogram)

Monogram field: Black opaque, matte finish

Cement Monogram to face behind opaque areas only

51

10

7/32" [6] 4 1/2" [114]

~

Scale: 1/2"=1’-0"

0

Front View

51

11

12

18

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

Dynamic Monogram field: GE color G 05 C Grey opaque (applied to 1st surface) matte finish

similar

51

11

7/32" [6]

4’-0" [1219] retainer 9/16" [14]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

c

Dynamic Monogram letters/curlicuesGE color G 02 C Grey opaque, matte finish

GE Silicones

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

g

51

9

1’-6" [457]

9’-11 9/16" [3037] face

10’-0" [3048] retainer

5/32" [4] 3’-11 5/8" [1210] face

Ground Sign, G-6 Face Fabrication Elevation

4 1/2" [114] 1’-6" [457] 9 3/16" 6 3/4" 9" [229] [233] [171]

285, Facility Signs Engineering Drawings

7/32" [6]

GE Identity Program

285.09.50

Ground Sign, G-6 Face Fabrication Elevation 285.09.50

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1’-6" [457] Monogram

5/16" [8]

0

5/16" [8]

1/8" [3]

1 1/2

3

Inches

.125 W7328 white acrylic x 1’-6" dia. (cement to Lexan face behind opaque areas only)

.315 Lexan face (clear)

3/16" dia. alum. stud welded to overlay w/ washer & elastic stop nut (as req’d. to maintain adequate attachment of alum to acrylic)

3/16" dia. alum. stud welded to letter w/ elastic stop nut & wide flat washer (place as req’d. for adequate attachment, 2 min. per letter)

3/8" dia. hole, fill w/ silicone

.315 Lexan face (clear)

1’-5 3/4" dia. clear face opaque Grey face area behind Monogram

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

0 3

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

Letter Attachment Detail

.125 alum. letter

1/4" [6]

Scale: 3"=1’-0"

Section 9

.090 alum. overlay @ Monogram field: Black, matte finish

Monogram letters/curlicues: .500 clear acrylic w/ polished edges (cement to white acrylic)

Paint edge of alum. & acrylic Black

1/2" [13]

Scale: 3"=1’-0"

Section 10

Scale: 3"=1’-0"

0

1 1/2

1 1/2

7/16" [11] 5/16" [8]

0

5/16" [8]

3

3

Inches

Drill & csk. for #10 flat hd. screw @ 18" c/c (@ sides only)

Extruded alum. retainer #GE-112

.315 Lexan lug, cont. (cement to face)

Extruded alum. "T" bar #GE-113

#10 pan hd. self-tapping screws @ 18" c/c

Inches

.125 flat alum. angle: 3 x 3 x 3/4 corner stiffener (weld one leg to retainer, rivet the other) typ. each corner

Extruded alum. "T" bar #GE-113

#10 pan hd. self-tapping screw @ 18" c/c

Extruded alum. retainer #GE-112

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 11

5/16" [8]

1/8" min. [3]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

#6 x 1/2" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 Lexan face (clear)

Alum. angle: 1 1/2 x 1 1/2 x 3/16 x 1/2" lg. corner stiffener (weld one leg to retainer, rivet the other) typ. each corner

.315 Lexan lug, cont. (cement to face)

#6 x 1/2" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

.315 Lexan face (clear)

5/16" [8] 1/8" min. [3]

1/16" [2] 1/8" [3]

285, Facility Signs Engineering Drawings 1/4" [6] 1/4" [6]

GE Identity Program 1/8" [3]

Ground Sign, G-6 Face Fabrication Details

285.09.51

Ground Sign, G-6 Face Fabrication Details 285.09.51

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

4’-0" [1219]

4 1/2" [114]

g

1’-6" [457]

g

1’-6" [457]

c

Scale: 1/4"=1’-0"

0

12

Face Layouts 36

48

Inches

4 1/2" [114]

4 1/2" [114]

1’-6" [457]

c 10’-0" [3048]

c

Medium Length Name

GE Aircraft Engines

10’-0" [3048]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

g GE Superabrasives

1’-6" [457]

g

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

Laser Line: GE color Laser Red (typ.)

Graphics: Black (typ.)

Background: GE color G 02 C Grey (typ.)

Dynamic Monogram letters/ curlicues: GE color G 02 C Grey (typ.)

Dynamic Monogram field: GE color G 05 C Grey (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

10’-0" [3048]

Short Name

GE Silicones

c

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

4’-0" [1219]

4 1/2" [114]

9" 1’-6" [229] [457]

6 3/4" [171]

4 1/2" [114]

1’-6" [457]

1’-8 7/16" [519]

9/16" [14]

~

4 1/2" [114]

4 1/2" [114]

9/16" [14]

10’-0" [3048]

9 5/8" [244]

9 3/16" 9/16" [233] [14]

3 1/4" typ. [83]

8 5/8" typ. [219]

4’-0" [1219] 4’-0" [1219]

3 3/8" [86] 1’-5 5/8" 9" typ. [448] [229]

4 1/2" [114] 1’-2 5/8" 1’-6" [371] [457] 10 5/16" [262] 4 1/2" [114] 8 5/8" 1’-6" [219] [457] 6 1/2" [165]

285, Facility Signs Engineering Drawings 9/16" [14]

GE Identity Program 9 13/16" [249]

Ground Sign, G-6 Sample Face Layouts

285.09.52

Ground Sign, G-6 Sample Face Layouts 285.09.52

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1 02

Scale: 3/8"=1’-0"

0

12

Front Elevation

~

24

Inches

6’-1 1/4" [1861]

Wall Sign, Cantilever Mount, WC-6 Sign Elevation & Installation Drawing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Non-illuminated Instructions This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction will be identical to what is detailed except as follows: 1. Internal illumination will be eliminated. 2. Face background color will be GE color G 02 C Grey, not White (sign filler and retainers also GE color G 02 C Grey).

Electrical Information Lamps: (7) GE F72T12 DL/HO Ballasts: (1) 3-lamp & (1) 4-lamp Amperage: 6.15 amps Circuits: (1) 20A/120V

Installation Instructions The erector shall be responsible for determining if wall conditions are adequate for supporting the wall cantilever sign. The installation, and additional support members if required, shall meet all applicable codes. It is strongly suggested that each installation be designed by a registered engineer licensed to practice in the state where the installation is located.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Disconnect switch

GE Capital

g

1 1/2" [38]

6’-1 1/4" [1861]

Plan

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

9" [229]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face background, White translucent

See sheet 03 for signbox fabrication

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Mounting bolt location (typ.)

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

Escutcheon: GE color G 03 C, Grey, matte finish

Face hinged for service

Reveal GE color G 03 C, Grey

Paint filler White to match face

1’-2" [356] 1’-9 5/8" [549]

Face of wall

~

285, Facility Signs Engineering Drawings 2’-6" [762]

~ 1’-9 5/8" [549]

GE Identity Program

285.11.01

Wall Sign, Cantilever Mount, WC-6 Sign Elevation & Installation Drawing 285.11.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Pop rivet escutcheon (typ.)

Face of wall

Plate: 3/8 x 9 x 36

L: 1 1/2 x 1 1/2 x 3/16 w/ 1/8" end plates

1/2" dia. expansion anchor or thru bolt (4-req’d.): Contractor shall verify wall conditions and have engineer design actual attachment. Each bolt shall be designed for 6300 lbs. of pullout

.125 formed alum. escutcheon

6" [152]

1 1/2

typ.

3

Inches

L: 1 x 1 x 1/8, cont. (weld to retainer @ hinged face only)

Extruded alum. retainer #GE-118

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c

1/8"

6’-1 1/4" [1861]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

1 1/2" [38]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Section 1

Pop rivet escutcheon @ 18" c/c w/ flat hd. csk. rivet. Attach retainer angle w/ #8 flat hd. csk. self-tapping screw @ 18" c/c (typ.)

Alum. angle: 1 1/2 x 1 1/2 x 1/8 (weld to filler) cont. (typ.)

1/8"

9" [229]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.315 Lexan face w/ White translucent film on 2nd surface

1/8" x 3/4" cont. neoprene gasket

Extruded alum. filler #GE-111

(2) 3/8" dia. truss hd. machine screw, nut & washer: gage = 6" (8-req’d. total)

Plate: 1/4 x 5 x 9 (typ. 2 places per tube)

TS: 3 x 3 x 3/16

Extruded alum. retainer clip #GE-119

#8 flat hd. csk. self-tapping screw @ 18" c/c (typ.)

Wall Sign, Cantilever Mount, WC-6 Installation & Fabrication Details

285.11.02

Wall Sign, Cantilever Mount, WC-6 Installation & Fabrication Details 285.11.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 1 1/2"=1’-0"

Section 2 0

3

24

6

Inches

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Extruded alum. retainer #GE-118

Extruded alum. filler #GE-111

Lifting angle: 2 x 2 x 3/16 x 1’-0"

Face prop assembly

02

1

Lifting angle: 2 x 2 x 3/16 x 1’-0" w/ (2) 1" dia. holes (remove after installation)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0 12

(7) GE F72T12 DL/HO lamps

1/2" dia. flex conduit (typ.)

TS: 3 x 3 x 3/16 (typ.)

Scale: 3/8"=1’-0"

03

2

Kulka socket #583-G

Front View

1 1/2" [38]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(2) 1/2" dia. rd. hd. screw @ 9" c/c & alum. nut (weld nut inside filler) remove angle & replace screws after installation

.090 x 1 x 1 x 3" lg. alum. hinge (3 @ one face) w/ (3) #10 flat hd. self-tapping screws @ filler, weld to retainer

1/4" dia. weep holes as req’d.

.125 formed alum. escutcheon

(1) 3-lamp & (1) 4-lamp ballast

Location of (2) 1/2" dia. bolts @ 6" c/c (typ.)

1/2" conduit & close nipple w/ locknuts @ electrical outlet location

L: 1 1/2 x 1 1/2 x 3/16 w/ plate: 1/8 x 1 1/4 x 1 1/4 welded each end (typ.)

Kulka socket #582-G

Alum. L: 2 x 2 x 3/16: (2) x 2" lg., (1) x 5" lg. corner stiffeners (typ. each corner)

Face of wall

6’-1 1/4" [1861]

1’-9 5/8" [549] 2’-6" [762]

6 5/8" [168] 6 spaces @ 10" = 5’-0" [1524] 6 5/8" [168]

285, Facility Signs Engineering Drawings 1’-9 5/8" [549]

9"

6’-1 1/4" [1861]

GE Identity Program [229]

Wall Sign, Cantilever Mount, WC-6 Signbox Fabrication Drawing

285.11.03

Wall Sign, Cantilever Mount, WC-6 Signbox Fabrication Drawing 285.11.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

g

05

4

1’-6" [457] 3 05

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

Front View 6

18

24

Inches

9/16" [14]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

GE Capital

6" [152]

15/16" [24]

15/16" [24] 5’-11 3/8" [1813] face

5’-11 3/8" [1813] face

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.315 clear SG-100 Lexan face w/ White translucent 3M film #3630-20 on second surface

Laser Line: film to match GE color Laser Red translucent applied to first surface

.250 flat cut-out alum. letters painted black, matte finish (bolt to face, see Letter Attachment Detail, sheet 05, typ.)

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

Monogram: see Section 4, sheet 05 for fabrication & attachment details

15/16" [24]

6" [152] 1’-6" [457] 1’-6" [457] 9 1/2" [241] 7 1/8" [181] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1’-2 1/16" [357]

285, Facility Signs Engineering Drawings 15/16" [24]

6’-1 1/4" [1861] retainer

Wall Sign, Cantilever Mount, WC-6 Face Fabrication Elevation

6’-1 1/4" [1861] retainer

GE Identity Program

285.11.04

Wall Sign, Cantilever Mount, WC-6 Face Fabrication Elevation 285.11.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: Half

0

Inches

1/4" [6]

5/16" [8]

Scale: Half

0

3/4

1 1/2

3/8" [10]

Scale: Half

3/4

1 1/2

Inches

.315 clear Lexan face w/ White translucent film on 2nd surface

.125 clear acrylic x 1’-6" dia. (cement to face behind opaque areas only)

3/16" alum. stud welded to overlay w/ washer & elastic stop-nut (as req’d. to maintain adequate attachment of alum. to acrylic)

Paint edge of alum. & acrylic Black

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1/8" [3]

5/16" [8]

Wall Sign, Cantilever Mount, WC-6 Face Fabrication Details

Section 4

.090 alum. overlay @ Monogram field: Black, matte finish

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

1’-6" [457] Monogram Monogram letters/curlicues: .375 clear acrylic w/ polished edges (cement to clear acrylic back-up)

3/16" alum. stud welded to letter, w/ elastic stop-nut & wide flat washer (place as req’d. for adequate attachment, min. (2) per letter)

Letter Attachment Detail

3/8" dia. hole, fill w/ silicone

.250 alum. letter

.315 Lexan face

1 1/2

#10 pan hd. self-tapping screw @ 18" c/c

Extruded alum. retainer clip #GE-119

Alum. angle: 1 1/2 x 1 1/2 x 1/8 x 1/2" lg. (weld to one retainer, rivet to the other) typ. each corner

.315 x 1/4" Lexan lug cont. (cement to face)

Alum. angle: 1 1/2 x 1 1/2 x 1/2 x 1/8 thick (weld to one retainer, (2) flat hd. screws other retainer) typ. each corner

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

1 7/8" [48]

Section 3

.315 clear Lexan face w/ White translucent film on 2nd surface

#4 x 1/2"- type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

2" [51]

Extruded alum. retainer #GE-118

15/16" [24] 5/32" [4]

GE Identity Program

285.11.05

Wall Sign, Cantilever Mount, WC-6 Face Fabrication Details 285.11.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

6’-1 1/4" [1861]

6" [152] 6" min. [152]

GE color Laser Red Laser Line (typ.)

Black graphics (typ.)

White translucent background (typ.)

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

Scale: 1/4"=1’-0"

0

24

36

48

Inches

6" [152]

6" [152]

1’-6" [457]

6" min. [152]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

GE Superabrasives

g

1’-6" [457]

6’-1 1/4" [1861]

Medium Length Name

GE Aircraft Engines

6" min. [152]

6’-1 1/4" [1861]

g

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

Face Layouts

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

g

1’-6" [457]

6’-1 1/4" [1861]

Short Name

GE Silicones

g

6" min. [152]

~

1’-6" [457]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

6’-1 1/4" [1861]

1’-6" 6" [457] [152]

8 3/4" 1’-6" [222] [457]

1’-3 3/8" [391]

7 5/8" typ. [194]

2 7/8" typ. [73]

1’-6" 6" [457] [152]

6 9/16" [167]

9/16" [14]

7 5/8" [194]

9/16" [14]

6’-1 1/4" [1861] 6’-1 1/4" [1861]

6" [152]

5 3/4" [146]

9 3/4" 1’-6" 6" [248] [457] [152] 8 1/2" [216] 1’-2 1/2" 1’-6" 6" [368] [457] [152] 11 1/2" 9/16" [292] [14]

9 3/4" typ. [248] 3 5/8" [92] 9/16" [14] 2 3/4" [70]

285, Facility Signs Engineering Drawings 7 1/4" typ. [184]

6’-1 1/4" [1861]

5 7/16" [138]

GE Identity Program

6 11/16" [170]

7 5/16" [186]

Wall Sign, Cantilever Mount, WC-6 Sample Face Layouts

285.11.06

Wall Sign, Cantilever Mount, WC-6 Sample Face Layouts 285.11.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1 22

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face of wall

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Monogram letters/curlicues: White translucent

Mounting bolt location (typ.)

Monogram field: Black opaque, matte finish

Escutcheon: GE color G 03 C Grey, matte finish

Reveal GE color G 03 C Grey

0

6

12

24

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

18

GE Capital

g

1 1/2" [38]

4’-1 1/4" [1251]

Front Elevation

9" [229]

Plan

Face hinged for service

Wall Sign, Cantilever Mount, WC-4 Sign Elevation & Installation Drawing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Non-illuminated Instructions This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction will be identical to what is detailed except as follows: 1. Internal illumination will be eliminated. 2. Face background color will be GE color G 02 C Grey, not White (sign filler and retainers also GE color G 02 C Grey).

Electrical Information Lamps: (5) GE F48T12 DL/HO Ballasts: (1) 2-lamp & (1) 3-lamp Amperage: 3.75 amps Circuits: (1) 20A/120V

Installation Instructions The erector shall be responsible for determining if wall conditions are adequate for supporting the wall cantilever sign. The installation, and additional support members if required, shall meet all applicable codes. It is strongly suggested that each installation be designed by a registered engineer licensed to practice in the state where the installation is located.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Disconnect switch

4’-1 1/4" [1251]

Filler: White to match face

1’-2" [356] 10 3/8" [264] 2’-4 1/2" [724]

~ 10 3/8" [264]

GE Identity Program

285.11.21

Wall Sign, Cantilever Mount, WC-4 Sign Elevation & Installation Drawing 285.11.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

L: 1 x 1 x 1/8 cont. (weld to retainer @ hinged face only)

Face of wall

Rivet escutcheon @ 18" c/c w/ flat hd. csk. rivet. Attach retainer angle w/ #8 flat hd. csk. self-tapping screw @ 18" c/c (typ.)

Alum. angle: 1 1/2 x 1 1/2 x 1/8 (weld to filler) cont. (typ.)

TS: 2 x 2 x 3/16

Plate: 3/8 x 8 x 33

3/8" dia. expansion anchor or thru bolt (4-req’d.): Contractor shall verify wall conditions & have engineer design actual attachment. Each bolt shall be designed for 2570 lbs. of pullout.

L: 1 1/2 x 1 1/2 x 3/16 w/ plate: 1/8 x 1 1/4 x 1 1/4 welded each end

.125 alum. formed escutcheon

Pop rivet escutcheon (typ.)

1/8"

1 1/2" [38]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Section 1

6" [152]

5" [127]

GE Identity Program 1 1/2

3

Inches

typ.

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

1/8"

4’-1 1/4" [1251]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.315 clear Lexan face w/ White translucent film on 2nd surface

1/8" x 3/4" cont. neoprene gasket (typ.)

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c

Extruded alum. filler #GE-111

Plate: 1/4 x 4 x 8 (typ.)

3/8" dia. truss hd. mach. screw, nut & washer: gage = 5" (8-req’d. total)

Plate: 1/4 x 4 x 8 (typ. 2 places per tube)

Extruded alum. retainer clip #GE-119

#8 flat hd. csk. self-tapping screw @ 18" c/c (typ.)

Extruded alum. retainer #GE-118

Wall Sign, Cantilever Mount, WC-4 Installation & Fabrication Details

285.11.22

Wall Sign, Cantilever Mount, WC-4 Installation & Fabrication Details 285.11.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 0 6

12

18

24

Inches

TS: 2 x 2 x 3/16 column (typ.)

1 22

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

2 23

(5) GE F48T12 DL/HO lamps

Kulka socket #582-G

Kulka socket #583-G

Front View

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1/4" dia. weep holes as req’d.

.125 formed alum. escutcheon

(1) 2-lamp ballast & (1) 3lamp ballast

1/2" dia. conduit & close nipple w/ locknuts @ electrical outlet location

1/2" dia. flex conduit (typ.)

Location of (2) 3/8" dia. bolts @ 5" c/c (typ.)

L: 1 1/2 x 1 1/2 x 3/16 w/ plate: 1/8 x 1 1/4 x 1 1/4 welded to each end

Face of wall

1 1/2" [38] Extruded alum. filler #GE-111

Lifting angle: 2 x 2 x 3/16 w/ (2) 1" dia. holes (remove after installation)

5 5/8" [143] 4 spaces @ 9 1/2" = 3’-2" [965] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Scale: 1 1/2"=1’-0"

Section 2

(2) 1/2" dia. rd. hd. screw @ 9" c/c & alum. nut (weld nut inside filler) remove angle & replace screws after installation

.090 x 1 x 1 x 3" lg. alum. hinge (3 @ one face) w/ (3) #10 flat hd self-tapping screws @ filler, weld to retainer

Face prop assembly

5 5/8" [143]

10 3/8" [264] 2’-4 1/2" [724]

4’-1 1/4" [1251]

4’-1 1/4" [1251]

GE Identity Program 10 3/8" [264]

Alum. angle: 2 x 2 x 3/16(2) x 2" lg. (1) x 5" lg. corner stiffeners (typ. each end)

6" [152]

3

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Extruded alum. filler #GE-111

Extruded alum. retainer #GE-118

Lifting angle: 2 x 2 x 3/16 x 1’-0" lg.

Wall Sign, Cantilever Mount, WC-4 Signbox Fabrication Drawing

285.11.23

Wall Sign, Cantilever Mount, WC-4 Signbox Fabrication Drawing 285.11.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3 25

4 25

1’-0" [305]

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

Front View 12

Inches

15/16" [24]

3/8" [10] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

GE Capital

g ~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Laser Line: film to match GE color Laser Red translucent applied to 1st surface

.315 clear SG-100 Lexan face w/ White translucent 3M film #3630-20 on 2nd surface

.250 flat cut-out alum. letters painted black, matte finish (bolt to face, see Letter Attachment Detail, sheet 25, typ.)

Monogram letters/curlicues: White translucent

Monogram field: black opaque, matte finish

Monogram: see Section 4, sheet 25 for fabrication & attachment details

4" [102]

3’-11 3/8" [1203] face

15/16" [24] 3’-11 3/8" [1203] face

15/16" [24]

4" [102] 1’-0" [305] 1’-0" [305] 4 11/16" 6 1/4" [119] [159]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

9 15/16" [252]

285, Facility Signs Engineering Drawings 15/16" [24]

4’-1 1/4" [1251] retainer

Wall Sign, Cantilever Mount, WC-4 Face Fabrication Elevation

4’-1 1/4" [1251] retainer

GE Identity Program

285.11.24

Wall Sign, Cantilever Mount, WC-4 Face Fabrication Elevation 285.11.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 0

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 3

.315 clear Lexan face w/ White translucent film on 2nd surface

#4 x 1/2" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

2" [51]

GE Identity Program

15/16" [24] 5/32" [4]

Extruded alum. retainer #GE-118

3

Inches

5/16" [8]

0

1 1/2

3

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

3/8" [10]

5/16" [8]

Scale: 3"=1’-0"

0

1/8" [3]

1 1/2

3

Inches

.315 clear Lexan face w/ White translucent film on 2nd surface

.125 clear acrylic x 1’-0" dia. (cement to face behind opaque areas only)

3/16" alum. stud welded to overlay w/ washer & elastic stop-nut (as req’d.to maintain adequate attachment of alum. to acrylic)

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Section 4

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

1’-0" monogram

Monogram letters/curlicues: .375 clear acrylic w/ polished edges (cement to clear acrylic back-up)

.090 alum. overlay @ Monogram field: Black, matte finish

Paint edge of alum. & acrylic Black

3/16" alum. stud welded to letter, w/ elastic stop-nut & wide flat washer (place as req’d. for adequate attachment, min. (2) per letter)

Letter Attachment Detail

3/8" dia. hole, fill w/ silicone

1/4" [6]

Extruded alum. retainer clip #GE-119

#10 pan hd. self-tapping screw @ 18" c/c

Alum. angle: 1 1/2 x 1 1/2 x 1/8 x 1/2" lg. (weld to one retainer, rivet to other retainer) typ. each end

.315 x 3/8" Lexan lug cont. (cement to face)

Alum. angle: 1 1/2 x 1 1/2 x 1/2 x 1/8" thick (weld to one retainer, (2) sht. metal screws @ other retainer) typ. each end

.250 alum. letter

.315 Lexan face

1 1/2

1 7/8" [48]

Wall Sign, Cantilever Mount, WC-4 Face Fabrication Details

285.11.25

Wall Sign, Cantilever Mount, WC-4 Face Fabrication Details 285.11.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

4’-1 1/4" [1251]

4" [102]

4" [102]

4" min. [102]

4" min. [102]

Scale: 3/8"=1’-0"

12

24

Inches

4" [102]

4" [102]

4" min. [102]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

GE Superabrasives

g

1’-0" [305]

4’-1 1/4" [1251]

Medium Length Name

GE Aircraft Engines

4" min. [102]

4’-1 1/4" [1251]

g

1’-0" [305]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

Laser Line: GE color Laser Red (typ.)

Black graphics (typ.)

White translucent background (typ.)

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

g

1’-0" [305]

4’-1 1/4" [1251]

Short Name

GE Silicones

g

1’-0" [305]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

4’-1 1/4" [1251]

1’-0" 4" [305] [102]

5 7/8" 1’-0" [149] [305]

4 3/8" [111]

1’-0" 4" [305] [102]

5 1/8" [130]

4 5/8" 3/8" [117] [10]

3/8" [10]

4’-1 1/4" [1251]

3 7/8" [98]

10 5/8" [270]

1 15/16" typ. [49]

5 1/8" typ. [130]

4’-1 1/4" [1251] 4’-1 1/4" [1251]

6 1/2" 1’-0" 4" [165] [305] [102] 6 1/16" 3/8" [154] [10] 1’-0" 4" [305] [102] 9 3/4" [248]

6 1/2" typ. [165] 2 7/16" [62] 4 7/8" typ. [124] 1 13/16" [46]

285, Facility Signs Engineering Drawings

3 5/8" [92]

GE Identity Program

~ 7 15/16" 3/8" [202] [10]

4 7/8" [124]

Wall Sign, Cantilever Mount, WC-4 Sample Face Layouts

285.11.26

Wall Sign, Cantilever Mount, WC-4 Sample Face Layouts 285.11.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

g

02

1

4’-4 7/8" [1343]

1’-9 1/8" [537]

Scale: 3/8"=1’-0"

24

Inches

1’-1 1/4" [337]

Face of wall

Disconnect switch

Face hinged for service

Filler: White to match face

Side Elevation

5’-1 1/2" [1562]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Non-illuminated Instructions This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction will be identical to what is detailed except as follows: 1. Internal illumination will be eliminated. 2. Face background color will be GE color G 02 C Grey, not White (sign filler and retainers also GE color G 02 C Grey). 3. If desired, the standard 1/4 version of the Dynamic Monogram may be used (GE color G 05 C Grey field).

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Electrical Information Lamps: (13) GE F60T12 DL/HO Ballasts: (3) 3-lamp & (1) 4-lamp Amperage: 9.4 amps Circuits: (1) 20A/120V

12

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Front Elevation

GE Silicones

4’-9 7/8" [1470]

Installation Instructions The erector shall be responsible for determining if wall conditions are adequate for supporting the wall flush sign. The installation, and additional support members if required, shall meet all applicable codes. It is strongly suggested that each installation be designed by a registered engineer licensed to practice in the state where the installation is located.

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Mounting bolt location (typ.)

Laser Line: GE color Laser Red translucent

Graphics: Black opaque, matte finish

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 03 for signbox fabrication details

1’-9 1/8" [537]

12’-9" [3886]

6" [152] 4’-1 1/2" [1257] 6" [152]

Wall Sign, Flush Mount, WF-5 Sign Elevation & Installation Drawing

~

GE Identity Program

285.13.01

Wall Sign, Flush Mount, WF-5 Sign Elevation & Installation Drawing 285.13.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

F60T12 DL/HO lamp

.315 clear Lexan face w/ White translucent film on 2nd surface

Scale: 3"=1’-0"

Section 1

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c (weld clip angles to filler as req’d.)

Extruded alum. retainer clip #GE-119

Extruded alum. retainer #GE-118

(4) .090 x 1 x 1 x 3" lg. alum. hinge w/ (3) #10 flat hd. selftapping screws @ filler, weld to retainer

Extruded alum. filler #GE-111

(2) 1/2" dia. rd. hd. screws @ 9" c/c & alum. nut (weld nut inside filler) remove angle & replace screws after installation

1 1/2

3

1/8"

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

cont.

1/8"

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

.125 alum. back (pop rivet to angle all around @ 18" c/c)

1/2" dia. mounting bolt (6-req’d.) exact attachment to be designed based upon field conditions

Alum. mounting plate: 1/4 x 4 x6

Alum. tube: 2 x 2 x 1/8

1/8" x 1/2" cont. neoprene gasket (typ.)

Seal w/ silicone caulking

Alum. angle: 1 1/8 x 1 x 1/8 w/ #10 flat hd. csk. self-tapping screws @ 18" c/c

Lifting angle: 2 x 2 x 3/16 x 1’-0" lg.

Wall Sign, Flush Mount, WF-5 Installation & Fabrication Details

285.13.02

Wall Sign, Flush Mount, WF-5 Installation & Fabrication Details 285.13.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Scale: 1/2"=1’-0"

0

Front View

(3) 3-lamp ballast & (1) 4-lamp ballast

Kulka socket #582-G

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

~

Kulka socket #583-G

12

18

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

4’-4 7/8" [1343]

4’-4 7/8" [1343]

02

1

12 spaces @ 11 3/4" = 11’-9" [3581]

Lifting angle: 2 x 2 x 3/16 w/ (2) 1" dia. holes (remove after installation)

4’-9 7/8" [1470]

1’-9 1/8" [537]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face prop rod assembly (typ.)

1/4" dia. weep hole as req’d.

Alum. angle: 2 x 2 x 3/16 (2) x 2" lg., (1) x 5" lg. corner stiffeners (typ. each corner)

Alum. tube: 2 x 2 x 1/8 vertical w/ (2) alum. plates1/4 x 4 x 6 mounting plates (typ.)

1/8 x 1 1/4 x 4 alum. ballast box & cover (weld to t & b fillers) typ.

Alum. angle: 1 x 1 x 1/8 stiffener (typ.)

(13) GE F60T12 DL/HO lamps

Extruded alum. filler #GE-111

4’-4 7/8" [1343]

1’-11 5/8" [600]

6" [152]

12’-9" [3886]

1’-0" [305]

2" x 4" jct. box @ elect. outlet loc.

5’-1 1/2" [1562] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Bell flush disconnect switch #216-20-OG w/ Bell box #250

1/2" dia. flex. conduit

4" typ. [102]

1 1/2" typ. [38]

1’-9 1/8" [537]

1’-11 5/8" [600]

6" [152]

6" [152] 4’-1 1/2" [1257]

Wall Sign, Flush Mount, WF-5 Signbox Fabrication Drawing

2’-6 3/4" [781]

285, Facility Signs Engineering Drawings

6" [152]

GE Identity Program

285.13.03

Wall Sign, Flush Mount, WF-5 Signbox Fabrication Drawing 285.13.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Scale: 3/8"=1’-0"

12

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Front View

GE Silicones

.250 flat cut-out alum. letters painted Black, matte finish (bolt to face, see Letter Attachment Detail, sheet 05) typ.

12’-7 1/8" [3839] face

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

05

2

2’-0" [610]

g

6" [152]

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Laser Line: film to match GE color Laser Red translucent applied to 1st surface

.315 clear Lexan face w/ White translucent 3M film #3630-20 on 2nd surface

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

Monogram: see Section 2, sheet 05 for fabrication & attachment details— cement Monogram to face behind opaque areas only

05

3

15/16" [24]

5’-1 1/2" [1562] retainer 3/4" [19]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2" typ. [51]

15/16" [24]

15/16" [24] 4’-11 5/8" [1514] face

12’-9" [3886] retainer

Wall Sign, Flush Mount, WF-5 Face Fabrication Elevation

6" [152] 2’-0" [610] 1’-0" [305] 9 3/4" 9" [248] [229]

285, Facility Signs Engineering Drawings

15/16" [24]

GE Identity Program

285.13.04

Wall Sign, Flush Mount, WF-5 Face Fabrication Elevation 285.13.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: Half

0

Inches

1/4" [6]

5/16" [8]

Scale: Half

0

3/4

1 1/2

3/8" [10]

Scale: Half

3/4

1 1/2

Inches

.315 clear Lexan face w/ White translucent film on 2nd surface

.125 clear acrylic x 2’-0" dia. (cement to face behind opaque areas only)

3/16" alum. stud welded to overlay w/ washer & elastic stop-nut (as req’d. to maintain adequate attachment of alum. to acrylic)

Paint edge of alum. & acrylic Black

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1/8" [3]

5/16" [8]

Wall Sign, Flush Mount, WF-5 Face Fabrication Details

Section 2

.090 alum. overlay @ Monogram field: Black, matte finish

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

2’-0" [610] Monogram Monogram letters/curlicues: .375 clear acrylic w/ polished edges (cement to clear acrylic back-up)

3/16" alum. stud welded to letter, w/ elastic stop-nut & wide flat washer (place as req’d. for adequate attachment, min. (2) per letter)

Letter Attachment Detail

3/8" dia. hole, fill w/ silicone

.250 alum. letter

.315 Lexan face

1 1/2

#10 pan hd. self-tapping screw @ 18" c/c

Extruded alum. retainer clip #GE-119

Alum. angle 1 1/2 x 1 1/2 x 1/8 x 1/2" lg. (weld to one retainer, rivet to the other) typ. each corner

.315 x 1/4" Lexan lug cont. (cement to face)

Alum. angle 1 1/2 x 1 1/2 x 1/2 x 1/8" thick (weld to one retainer, (2) flat hd. screws other retainer) typ. each corner

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

1 7/8" [48]

Section 3

.315 clear Lexan face w/ White translucent film on 2nd surface

#4 x 1/2"- type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

2" [51]

Extruded alum. retainer #GE-118

15/16" [24] 5/32" [4]

GE Identity Program

285.13.05

Wall Sign, Flush Mount, WF-5 Face Fabrication Details 285.13.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

5’-1 1/2" [1562]

6" [152]

6" [152]

g

2’-0" [610]

g

2’-0" [610]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

5’-1 1/2" [1562]

Scale: 1/4"=1’-0"

12

24

6" [152]

36

6" [152]

48

12’-9" [3886]

Medium Length Name

GE Aircraft Engines

12’-9" [3886]

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

g GE Superabrasives

2’-0" [610]

g

2’-0" [610]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

12’-9" [3886]

Short Name

GE color Laser Red Laser Line (typ.)

Background: White (typ.)

GE Silicones

Black graphics (typ.)

Monogram letters/curlicues: White (typ.)

Monogram field: Black (typ.)

12’-9" [3886]

1’-9" 1’-0" typ. 4 1/2" 1’-0" [533] [305] [114] [305]

6" [152]

2’-0" [610]

9" 1’-0" [229] [305]

6" [152]

2’-0" [610]

2’-0 3/4" [629]

3/4" [19]

9 3/4" 3/4" [248] [19]

11" typ. 8" [279][203]

4" typ. [102]

6" [152]

5’-1 1/2" [1562] 5’-1 1/2" [1562]

6" [152] 2’-0" [610] 11 1/4" 1’-7 1/2" [286] [495] 6" [152] 2’-0" [610] 11" [279] 11 1/2" [292]

285, Facility Signs Engineering Drawings 8 1/4" [210]

GE Identity Program

~ 3/4" [19]

Wall Sign, Flush Mount, WF-5 Sample Face Layouts

285.13.06

Wall Sign, Flush Mount, WF-5 Sample Face Layouts 285.13.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

g

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1

Mounting bolt location (typ.)

Scale: 1/2"=1’-0"

6

12

18

24

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

Disconnect switch

Filler: White to match face

Face hinged for service

Side Elevation

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Non-illuminated Instructions This sign may be installed as a non-illuminated or externally illuminated sign. If so, the sign construction will be identical to what is detailed except as follows: 1. Internal illumination will be eliminated. 2. Face background color will be GE color G 02 C Grey, not White (sign filler and retainers also GE color G 02 C Grey). 3. If desired, the standard 1/4 version of the Dynamic Monogram may be used (GE color G 05 C Grey field).

Graphics: Black opaque, matte finish

3’-1 1/2" [953]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Electrical Information Lamps: (7) GE F36T12 DL/HO Ballasts: (1) 3-lamp & (1) 4-lamp Amperage: 3.5 amps Circuits: (1) 20A/120V

0

Front Elevation

GE Silicones

22

10" [254]

1’-1 1/4" [337]

Wall Sign, Flush Mount, WF-3 Sign Elevation & Installation Drawing

~

Installation Instructions The erector shall be responsible for determining if wall conditions are adequate for supporting the wall flush sign. The installation, and additional support members if required, shall meet all applicable codes. It is strongly suggested that each installation be designed by a registered engineer licensed to practice in the state where the installation is located.

Laser Line: GE color Laser Red translucent

Face background: White translucent

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

See sheet 23 for signbox fabrication details

5’-10" [1778]

7’-6" [2286]

6" [152] 2’-1 1/2" [648]

10" [254]

~

285, Facility Signs Engineering Drawings 6" [152]

GE Identity Program

285.13.21

Wall Sign, Flush Mount, WF-3 Sign Elevation & Installation Drawing 285.13.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

F36T12 DL/HO lamp

.315 clear Lexan face w/ White translucent film on 2nd surface

Scale: 3"=1’-0"

Section 1

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.090 alum. raceway cover w/ sht. metal screws @ 18" c/c (weld clip angles to filler as req’d.)

Extruded alum. retainer clip #GE-119

Extruded alum. retainer #GE-118

(3) .090 x 1 x 1 x 3" lg. alum. hinge w/ (3) #10 flat hd. selftapping screws @ filler, weld to retainer

Extruded alum. filler #GE-111

(2) 1/2" dia. rd. hd. screws @ 9" c/c & alum. nut (weld nut inside filler) remove angle & replace screws after installation

1 1/2

3

1/8"

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

cont.

1/8"

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

.125 alum. back (pop rivet to angle all around @ 18" c/c)

1/2" dia. mounting bolt (4-req’d.) exact attachment to be designed based upon field conditions

Alum. mounting plate: 1/4 x 4 x6

Alum. tube: 2 x 2 x 1/8

1/8" x 1/2" cont. neoprene gasket (typ.)

Seal w/ silicone caulking

Alum. angle: 1 1/8 x 1 x 1/8 w/ #10 flat hd. csk. self-tapping screws @ 18" c/c

Lifting angle: 2 x 2 x 3/16 x 1’-0" lg.

Wall Sign, Flush Mount, WF-3 Installation & Fabrication Details

285.13.22

Wall Sign, Flush Mount, WF-3 Installation & Fabrication Details 285.13.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1

~

5’-10" [1778]

10" [254]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

12

Inches

4" typ. [102]

3’-1 1/2" [952] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Bell flush disconnect switch #216-20-OG w/ Bell box #250

1 1/2" [38] typ.

10" [254]

6" [152]

1’-0 1/2" [317]

1/2" dia. flex conduit

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

6

2" x 4" junction box @ elect. outlet location

(1) 3-lamp ballast & (1) 4-lamp ballast req’d.

Front View

Prop rod assembly

22

6’-6" [1981]

6" [152]

1/4" dia. weep holes as req’d.

Alum. plate: 1/4 x 4 x 6 for 1/2" dia. mounting bolts

Kulka socket #582-G

Alum. angle: 1 x 1 x 1/8 stiffener (typ.)

1/8 x 1 1/4 x 4 alum. ballast box w/ cover (typ.) weld to t & b filler

Alum. tube: 2 x 2 x 1/8 (typ.)

(7) GE F36T12 DL/HO lamps

Kulka socket #583-G

Alum. angle: 2 x 2 x 3/16 (2) x 2" lg.; (1) x 5" lg.; corner stiffener (typ. each corner)

Extruded alum. filler #GE-111

Lifting angle: 2 x 2 x 3/16 x 1’-0" lg. w/ (2) 1" dia. holes (remove after installation)

5’-5" [1651]

1’-0 1/2" [317]

6" [152] 2’-1 1/2" [648]

285, Facility Signs Engineering Drawings

6" [152]

7’-6" [2286]

Wall Sign, Flush Mount, WF-3 Signbox Fabrication Drawing

1’-6 3/4" [476]

GE Identity Program

285.13.23

Wall Sign, Flush Mount, WF-3 Signbox Fabrication Drawing 285.13.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

g Scale: 1/2"=1’-0"

0

12

18

24

Inches

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

GE Silicones Front View

2 25

3 25

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Laser Line: film to match GE color Laser Red translucent applied to first surface

.250 flat cut-out alum. letters painted Black, matte finish (bolt to face, see Letter Attachment Detail, sheet 25) typ.

.315 clear Lexan face w/ white 3M translucent film #3630-20 on 2nd surface

Monogram letters/curlicues: White translucent

Monogram field: Black opaque, matte finish

Monogram: see Section 2, sheet 25 for fabrication & attachment details

3 3/4" 1’-2 1/2" [95] [368]

7’-4 1/8" [2238] face

7’-6" [2286] retainer 15/16" [24]

Wall Sign, Flush Mount, WF-3 Face Fabrication Elevation

3’-1 1/2" [952] retainer Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

7/16" [11]

15/16" [24]

~

3 3/4" [95] 1’-2 1/2" [368] 6 1/8" 5 7/16" 7 1/4" [156] [138] [184]

15/16" [24] 2’-11 5/8" [905] face

285, Facility Signs Engineering Drawings 15/16" [24]

GE Identity Program

285.13.24

Wall Sign, Flush Mount, WF-3 Face Fabrication Elevation 285.13.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: Half

0

Inches

1/4" [6]

5/16" [8]

Scale: Half

0

3/4

1 1/2

3/8" [10]

1/2" [13]

Scale: Half

3/4

1 1/2

Inches

.315 clear Lexan face w/ White translucent film on 2nd surface

.125 clear acrylic x 1’-2 1/2" dia. (cement to face behind opaque areas only)

3/16" alum. stud welded to overlay w/ washer & elastic stop-nut (as req’d. to maintain adequate attachment of alum. to acrylic)

Paint edge of alum. & acrylic Black

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1/8" [3]

5/16" [8]

Wall Sign, Flush Mount, WF-3 Face Fabrication Details

Section 2

.090 alum. overlay @ Monogram field: Black, matte finish

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

1’-2 1/2" [368] Monogram Monogram letters/curlicues: .375 clear acrylic w/ polished edges (cement to clear acrylic back-up)

3/16" alum. stud welded to letter, w/ elastic stop-nut & wide flat washer (place as req’d. for adequate attachment, min. (2) per letter)

Letter Attachment Detail

3/8" dia. hole, fill w/ silicone

.250 alum. letter

.315 Lexan face

1 1/2

#10 pan hd. self-tapping screw @ 18" c/c

Extruded alum. retainer clip #GE-119

Alum. angle: 1 1/2 x 1 1/2 x 1/8 x 1/2" lg. (weld to one retainer, rivet to the other) typ. each corner

.315 x 3/8" Lexan lug cont. (cement to face)

Alum. angle: 1 1/2 x 1 1/2 x 1/2 x 1/8" thick (weld to one retainer, (2) flat hd. screws other retainer) typ. each corner

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4

1 7/8" [48]

Section 3

.315 clear Lexan face w/ White translucent film on 2nd surface

#4 x 1/2"- type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c

2" [51]

Extruded alum. retainer #GE-118

15/16" [24] 5/32" [4]

GE Identity Program

285.13.25

Wall Sign, Flush Mount, WF-3 Face Fabrication Details 285.13.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3’-1 1/2" [953]

3 3/4" [95]

3’-1 1/2" [953]

3 3/4" [95]

3 3/4" [95]

g

1’-2 1/2" [368]

g

1’-2 1/2" [368]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1’-2 11/16" 1’-2 1/2" [373] [368]

3 3/4" [95]

7 1/4" 1’-2 1/2" [184] [368]

5 7/16" [138]

5" [127]

7/16" [11]

4 1/8" [105]

7/16" [11]

6 1/8" [156]

6 3/4" typ. 2 1/2" typ. [64] [171]

7 1/4" [184]

3’-1 1/2" [953]

Scale: 3/8"=1’-0"

12

24

3 3/4" [95]

3 3/4" [95]

Inches

7’-6" [2286]

Medium Length Name

GE Aircraft Engines

7’-6" [2286]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long, One-word Name

gGE Superabrasives

1’-2 1/2" [368]

g

1’-2 1/2" [368]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Face Layouts

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Long Name

GE Electrical Distribution & Control

7’-6" [2286]

Short Name

GE color Laser Red Laser Line (typ.)

Background: White (typ.)

~

GE Silicones

Monogram letters/curlicues: White (typ.) Graphics: Black (typ.)

Monogram field: Black (typ.)

7’-6" [2286] 3 3/4" [95] 7" 11 13/16" 1’-2 1/2" [368] [178] [300] 3’-1 1/2" [953]

7 1/4" typ. [184] 7/16" [11] 3 3/4" [95] 6 1/2" 1’-2 1/2" [165] [368]

285, Facility Signs Engineering Drawings 4 7/8" [124]

7 3/8" [187] 2 3/4" [70] 1’-0 7/8" [327]

GE Identity Program 7 7/16" 7/16" [189] [11]

Wall Sign, Flush Mount, WF-3 Sample Face Layouts

285.13.26

Wall Sign, Flush Mount, WF-3 Sample Face Layouts 285.13.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings Monogram "B" 2’-0" 3’-0" 4’-0" 5’-0"

4’-0’

6’-0"

8’-0"

10’-0"

~ ~

Monogram

12’-9 5/8"

10’-2 7/8"

7’-8 1/8"

5’-1 1/2"

Height

Letters: White translucent faces, Black returns

Returns: Black

"A"

Monogram field: Black

Letters/curlicues: White translucent face, Black returns

10’-0"

8’-0"

6’-0"

4’-0"

"A"

(Not to scale)

2’-6"

2’-0"

1’-6"

1’-0"

"B"

varies

See sheets 11 & 12 for typ. fabrication details

Individual Elements, Illuminated Installation Elevation - Single-Line Layout

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

See sheets 13 thru 16 for fabrication details

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Single-line Layout

Laser Line: faces translucent GE color Laser Red, Black returns

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3 5/8"

2 7/8"

2 1/8"

1 1/2"

Laser Line

Spacing Dimensions

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Letters

Height

Monogram

Laser Line

Letters

GE Identity Program

285.15.01

Individual Elements, Illuminated Installation Elevation - Single-Line Layout 285.15.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings ~ Monogram

8’-9 5/8"

2 1/8"

3’-0" 4’-0" 5’-0"

6’-0"

8’-0"

10’-0"

14’-8 1/8"

"A"

10’-0"

8’-0"

6’-0"

4’-0"

2’-6"

2’-0"

1’-6"

1’-0"

"B"

(Not to scale)

See sheets 11 & 12 for typ. fabrication details

Individual Elements, Illuminated Installation Elevation - Stacked Layout

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

See sheets 13 thru 16 for fabrication details

Letters: White translucent face, Black returns varies

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1’-10 1/2"

1’-6"

1’-1 1/2"

9"

"C"

Stacked Layout

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3 5/8"

11’-8 7/8"

1 1/2"

2’-0"

4’-0’

2 7/8"

Height 5’-10 1/2"

Laser Line

Letters

Monogram

Height

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

"A" Letters/curlicues: White translucent face, Black returns

Spacing Dimensions

Laser Line: GE color Laser Red translucent face, Black returns

Returns: Black

~

Monogram

Monogram field: Black

Letters "C" Letters "B" Laser Line

GE Identity Program

285.15.02

Individual Elements, Illuminated Installation Elevation - Stacked Layout 285.15.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 7’-6"

10’-0"

12’-9 5/8"

10’-2 7/8"

7’-8 1/8"

5’-1 1/2"

Height

See sheets 13 thru 16 for fabrication details

See sheets 11 & 12 for typ. fabrication details

2’-6"

2’-0"

1’-6"

1’-0"

"A"

(Not to scale)

1’-3"

1’-0"

9"

6"

"B"

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

Optional Single-line Layout

Laser Line: GE color Laser Red translucent faces, Black returns

Black returns

varies Letters: White translucent faces, Black returns

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3 5/8"

2 1/8" 2 7/8"

4’-6" 6’-0"

8’-0"

1 1/2"

3’-0"

4’-0’

6’-0"

Laser Line

Letters

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

"A"

Letters/curlicues: White translucent faces, Black returns

Spacing Dimensions

~ ~

Monogram

Monogram

Height

Monogram field: Black

Monogram "A" Laser Line

"B" "B"

Individual Elements, Illuminated Installation Elevation Optional Single-Line Layout

Letters

GE Identity Program

285.15.03

Individual Elements, Illuminated Installation Elevation Optional Single-Line Layout 285.15.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3/4"=1’-0"

0

Front View

7" [178]

6

7" [178]

12

Inches

05

1

2’-0" [610]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Provide flush disconnect switch

Provide 1/4" dia. weep holes as req’d.

Mounting bolt location (typ. 4 places)

Monogram field: Black, gloss finish

Letters/curlicues: White translucent

Electrical outlet location

.125 alum. backing bar (welded to alum. ring & field) provide additional members if req’d. for secure attachment of all elements

45

o

2’-0" [610]

4’-0" [1219] dia.

7" [178]

2’-0" [610]

6 1/2" [165]

1/2" [13]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

Filler: Black, gloss finish

Individual Elements, Illuminated 4’0” Monogram Fabrication Elevations

Side View

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

7" [178]

285, Facility Signs Engineering Drawings 2’-0" [610]

GE Identity Program

285.15.04

Individual Elements, Illuminated 4’0” Monogram Fabrication Elevations 285.15.04

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings ~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

9" [229]

6

9" [229]

12

18

05

1

24

Inches

3’-0" [914]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

0

Front View

Provide flush disconnect switch

Provide 1/4" dia. weep holes as req’d.

Mounting bolt location (typ. 4 places)

Monogram field: Black, gloss finish

Letters/curlicues: White translucent

Electrical outlet location

.125 alum. backing bar (weld to alum. ring & field) provide additional members is req’d. for secure attachment of all members

45 (typ.)

o

3’-0" [914]

~

6’-0" [1829] dia.

3’-0" [914] 10" [254] 10" [254]

6 1/2" [165]

1/2" [13]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

Filler: Black, gloss finish

Individual Elements, Illuminated 6’0” Monogram Fabrication Elevations

Side View

2" [51]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3’-0" [914]

GE Identity Program

285.15.05

Individual Elements, Illuminated 6’0” Monogram Fabrication Elevations 285.15.05

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 1 1 1/2

3

Inches

1/2" [13]

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.125 x 3/4" alum. stiffener bar (weld to .125 alum. ring & field)

60 mA npf France PBKM-51 series transformer or equal as req’d.

.190 alum. back

1 3/4" tube stand w/ stand-off as req’d.

1/2" spacer

1/2" dia. lag bolt or thd. stud grouted into wall (4-req’d.)

Alum. angle: 2 x 1 1/2 x 1/8 (cont. all around)

#10 sht. metal screws @ 18" c/c

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

5" [127]

6 1/2" [165]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.125 alum. ring & field

.090 alum. returns (Black, gloss finish) weld to alum. background

Cut out background area behind illuminated graphics

(2) rows of 15mm 6500 White neon tubing

o

.187 R & H W7328 White plex faces (script & curly Q’s)

1" jewelite trimcap (Black, gloss finish) w/ #8 s.s. sht. metal screws @ 18" c/c

.125 alum. return

2" [51]

Individual Elements, Illuminated 4’0” & 6’0” Monogram Fabrication Details

285.15.06

Individual Elements, Illuminated 4’0” & 6’0” Monogram Fabrication Details 285.15.06

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

~

2

12

08

18

24

09

3

2’-8" [813]

4

09

1’-3" [381]

~

Southco fasteners or equal

Access door: flush to filler (typ. each end)

Cont. piano hinge @ top

Bell flush disconnect switch #216-20-OG w/ Bell box #250

Filler: Black, gloss finish

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side View

2" [51]

Individual Elements, Illuminated 8’0” Monogram Fabrication Elevations

5" [127]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

0

6

2’-8" [813]

Front View

Provide 1/4" dia. weep holes as req’d.

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

L: 1 1/2 x 1 1/2 x 3/16 brace (typ.)

Mounting location (typ. 4 places)

Electrical outlet location

Alum. channel: 1 3/8 x 1 1/4 x 3/16 x 4" lg. face support (12req’d. @ equal spaces)

Letters/curlicues: White acrylic, gloss finish

Bent plate: 1 1/2 x 1 1/2 x 3/16 (typ.)

Transformer: 12000v 60mA npf (2-req’d)

Transformer: 9000v 60mA npf (2-req’d.)

Monogram field: Black gloss finish

T: 2 x 1 1/2 x 1/4 (typ. 2 places, front & back)

Face splice (typ. 2 places)

3/4" dia. eyebolt

2’-8" [813]

8’-0" [2438] dia.

4’-0" [1219] 4’-0" [1219]

~

~

GE Identity Program

285.15.07

Individual Elements, Illuminated 8’0” Monogram Fabrication Elevations 285.15.07

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings Elect. outlet location

Face splice (typ. 3 places)

12

08

2

24

2’-6" [762]

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

0

Front View

Provide 1/4" dia. weep holes as req’d.

Mounting location (typ. 4 places)

2’-6" [762]

4

09

2’-0" [610]

~

~

1’-3" [381]

Face of wall

Southco fasteners or equal

Access door flush to filler (typ. each end)

Cont. piano hinge @ top

Bell flush disconnect switch #216-20-OG w/ Bell box #250

Filler: paint Black, gloss finish

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2" [51]

Individual Elements, Illuminated 10’0” Monogram Fabrication Elevations

Side View

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

09

3

2’-6" [762]

5" [127]

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

L: 1 1/2 x 1 1/2 x 3/16 (typ.)

Alum. channel: 1 3/8 x 1 1/4 x 3/16 x 4" lg. face support (12-req’d. @ equal spacing)

Letters/curlicues: White acrylic, gloss finish

C 3 x 5 (ns & fs)

Bent plate: 1 1/2 x 1 1/2 x 3/16 (typ.)

Transformer: 15000v 60mA npf (2-req’d.)

Transformer: 12000v 60mA npf (2-req’d.)

Monogram field: paint Black, gloss finish

T: 2 x 1 1/2 x 1/4 (typ. 3 places front & back)

2’-6" [762] 3/4" dia. eyebolt

~

~

10’-0" [3048] dia.

5’-0" [1524] 5’-0" [1524]

GE Identity Program

285.15.08

Individual Elements, Illuminated 10’0” Monogram Fabrication Elevations 285.15.08

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2" [51]

5 [127]

Scale: 1 1/2"=1’-0"

Section 2

typ.

3

6

Inches

2" [51]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

Back splice: pop rivet @ 12" c/c

T: 2 x 1 1/2 x 1/4

.125 alum. back- pop rivet to framing @ 18" c/c

C 3 x 5 (top only)

L: 1 1/2 x 1 1/2 x 3/16 frame (cont. all around) typ. front & back

.125 alum. filler: paint Black, gloss finish, pop rivet to frame @ 18" c/c

3/4" eyebolt for lifting: remove after installation & replace w/ 3/4" rd. hd. screw (weld nut inside channel)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

3/16"

1’-3" [381]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. angle: 1 1/2 x 1 1/2 x 3/16

.125 alum. face panel

C 3 x 5 (typ.)

Plate: 30 x 10 3/8 x 3/16

Standard glass electrode housing

1 3/4" tube stand (typ. as req’d.)

15mm 6500 white neon tubing (2 rows)

o

.250 R & H W7328 White acrylicgloss finish

2" Jewelite trim cap or equal w/ #8 s.s. sht. metal screws @ 12" c/c cont. (paint same as return)

Paint inside White

.090 alum. letter sides & backpaint Black, gloss finish

Fabricated alum. channel 1 3/8 x 1 1/4 x 3/16 x 4" lg. face support pop rivet to "L" frame

.125 alum. retainer: paint Black, gloss finish, attach w/ #10 flat hd. s.s. sht. metal screws @ 15" c/c

Individual Elements, Illuminated 8’0” & 10’0” Monogram Fabrication Details

285.15.09

Individual Elements, Illuminated 8’0” & 10’0” Monogram Fabrication Details 285.15.09

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings 0 3

6

Inches

1 1/2" [38]

~ to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 3

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Face panel splice

.125 alum. face panel

T: 2 x 1 1/2 x 1/4 (typ. front & back)

Pop rivet face panel @ 18" c/c (typ.)

3/16 x 10 1/4 x 30 transformer mounting plate

60mA npf transformer

L: 1 1/2 x 1 1/2 x 3/16

C 3 x 5 (typ.)

.125 alum. back

Scale: 3"=1’-0"

Section 4

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Alum. filler

L: 1 1/2 x 1 1/2 x 3/16 frame

Bent plate: 3/16 x 2 x 4 weld to frame "L" (typ. @ mounting locations)

Bent plate: 3/16 x 3 x 1 1/2 x 4" lg. w/ 1/2" dia. bolt, nut & washer (4-req’d.)

.125 alum. back

0

3

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

1/2" dia. bolt, nut & washer

Bent plate: 3/16 x 3 x 1 1/2 x 4" lg. w/ 1/2" dia. lag bolt or thd. stud grouted into wall (connection to be designed based on actual field conditions) 4-req’d.

Face of wall

Individual Elements, Illuminated 8’0” & 10’0” Monogram Fabrication Details

285.15.10

Individual Elements, Illuminated 8’0” & 10’0” Monogram Fabrication Details 285.15.10

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

4 3/4" [121]

0

3

Inches

1/4" dia. weep holes as req’d.

3/4" dia. rigid electrical conduit to power source

1/2" e.m.t.

Paint inside of letter White

Face of wall

.125 alum. back

3/8" spacer

1" min. [25] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

3/8" [10]

2 1/2" [64]

(2’-0", 3’-0" & 4’-6" Letters)

Scale: 1 1/2"=1’-0"

Typical Section

~

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 3/4" tube stand w/ standoff as req’d.

2" x 4" junction box

15mm 6500 White neon tubing (2 rows for 2’-0" & 3’-0" letters, 3 rows for 4’-6" letters)

o

.187 R & H W7328 White acrylic, gloss finish

60mA npf transformer

3/8" dia. stud w/ hex. nut & .125 x 1 1/2 x 1 1/2 alum. plate washer (grout into wall) space as req’d. to insure adequate attachment

1" Jewelite trim cap or equal w/ #8 s.s. sht. metal screws @ 12" c/c, cont. (paint same as return)

.125 alum. return: Black, gloss finish

8" [203]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Individual Elements, Illuminated 2’0”, 3’0”, & 4’6” Letter Fabrication Details

285.15.11

Individual Elements, Illuminated 2’0”, 3’0”, & 4’6” Letter Fabrication Details 285.15.11

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

6 1/2" [165]

0

3

Individual Elements, Illuminated 4’0”, 5’0”, 6’0”, & 7’6” Letter Fabrication Details

Inches

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1/4" dia. weep holes as req’d.

3/4" dia. rigid electrical conduit to power source

1/2" e.m.t.

Paint inside of letter White

.190 alum. back

3/8" spacer

1" min. [25] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

3/8" [10]

2 1/2" [64]

(4’-0", 5’-0", 6’-0" & 7’-6" Letters)

Scale: 1 1/2"=1’-0"

Typical Section

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 3/4" tube stand w/ stand-offs as req’d.

2" x 4" junction box

15mm 6500 white neon tubing (3 rows for 4’-0" & 5’-0" letters, 4 rows for 6’-0" letters & 5 rows for 7’-6" letters)

o

.250 R & H W7328 White acrylic, gloss finish

60mA npf transformer

3/8" dia. thd. stud w/ hex. nut & .125 x 1 1/2 x 1 1/2 alum. plate washer (grout into wall) space as req’d. to insure adequate attachment)

2" Jewelite trim cap or equal w/ #8 s.s. sht. metal screws @ 12" c/c, cont. (paint same as return)

.190 alum. return: Black, gloss finish

10" [254]

~

GE Identity Program

285.15.12

Individual Elements, Illuminated 4’0”, 5’0”, 6’0”, & 7’6” Letter Fabrication Details 285.15.12

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings (4’-0" monogram) 1 1/2" [38]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

4" [102]

3/8" [10]

Scale: 3"=1’-0"

1 1/2

3

Inches

Individual Elements, Illuminated 1 1 / 2” & 2 1 / 8” Laser Line Fabrication Details

.125 x 1 1/2" alum. mounting bar @ 3’-0" c/c

Face of wall

.125 alum. back

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4" rigid electrical conduit w/fitting @ electrical entry (electical service may be remote from letters above)

3/8" x 3" lg. exp. anchor or bolt grouted into wall (actual attachment to be designed based upon field conditions)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(for 4’-0" and 6’-0" monograms)

0

1 1/2" and 2 1/8" Laser Lines

Typical Cross Section

1/4" dia. weep holes as req’d.

.090 alum. channel section for mounting neon & glass housing (pop rivet to returns @ 18" c/c)

Std. glass housing

.090 alum. returns: paint Black, gloss finish

1 1/2" [38]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(1) row of 15mm clear red neon tubing w/ 1 1/4" tube stands as req’d.

.125 clear plex face w/ film to match GE color Laser Red translucent applied to 1st surface

(6’-0" monogram) 2 1/8" [54]

8" [203]

3/4" [19]

2" Jewelite trim cap w/ #8 s.s. sht. metal screws @ 18" c/c (paint same as return

3/16" + [5] 3/16" + [5]

1 1/2" [38]

GE Identity Program

285.15.13

Individual Elements, Illuminated 1 1 / 2” & 2 1 / 8” Laser Line Fabrication Details 285.15.13

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

2" Jewelite trim cap w/ #8 s.s. sht. metal screws @ 18" c/c (paint same as return) 6" [152]

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1 1/2

3

3/8" [10]

.125 x 1 1/2" alum. mounting bar @ 3’-0" c/c

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

3/4" rigid electrical conduit w/ fitting @ electrical entry (electrical service may be remote from letters above)

.190 alum. back

3/8" x 3" lg. exp. anchor or bolt grouted into wall (actual attachment to be designed based upon field conditions)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(for 8’-0" monogram)

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

2 7/8" Laser Line Inches

1/4" dia. weep holes as req’d.

(2) rows of 15mm clear red neon tubing w/ 1 1/4" tube stand as req’d.

Typical Cross Section

.090 alum. channel section for mounting neon & glass housing (pop rivet to returns @ 18" c/c)

.125 clear plex face w/ film to match GE color Laser Red translucent applied to 1st surface

Std. glass housing

1 1/2" [38]

10" [254]

Individual Elements, Illuminated 2 7 / 8” Laser Line Fabrication Details

3/4" [19]

.090 alum. returns: paint Black, gloss finish

3 1/4" [83] + -

3/16" + [5] 2 7/8" [73] 3/16" + [5]

1 1/2" [38]

GE Identity Program

285.15.14

Individual Elements, Illuminated 2 7 / 8” Laser Line Fabrication Details 285.15.14

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

.125 clear plex face w/ film to match GE color Laser Red translucent applied to 1st surface

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

~

Scale: 3"=1’-0"

1 1/2

3

Inches

3/8" [10] .125 x 1 1/2" alum. mounting bar @ 3’-0" c/c

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/4" rigid electrical conduit w/ fitting @ electrical entry (electrical service may be remote from letters above)

.190 alum. back

3/8" x 3" lg. exp. anchor or bolt grouted into wall (actual attachment to be designed based upon field conditions)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

(for 10’-0" monogram)

0

3 5/8" Laser Line

Typical Cross Section

.090 alum. transformer mounting bracket

1/4" dia. weep holes as req’d.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.090 alum. channel section for mounting neon (pop rivet to returns @ 18" c/c)

(2) rows of 15mm clear red neon tubing w/ 1 1/4" tube stand as req’d.

6" [152]

60mA npf transformer France PBKM-51 series or equal

1 1/2" [38]

10" [254]

3/4" [19]

2" Jewelite trim cap w/ #8 s.s. sht. metal screws @ 18" c/c (paint same as return)

Individual Elements, Illuminated 3 5 / 8” Laser Line Fabrication Details

1 1/2" [38]

.125 alum. returns: paint Black, gloss finish

4" [102] + -

3/16" + [5] 3 5/8" [92]

285, Facility Signs Engineering Drawings 3/16" + [5]

~

GE Identity Program

285.15.15

Individual Elements, Illuminated 3 5 / 8” Laser Line Fabrication Details 285.15.15

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

~

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

1 1/2

3

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Shipping Instructions Laser Lines should be fabricated and shipped in 8’-0" to 12’-0" sections, depending upon actual layouts.

Inches

Laser Line splice

Neon tubing: stop 3/4" back from splice points

2" Jewelite trim cap

.125 plex face

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

Typical Laser Line Splice Detail

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Alum. back

.125 x 3" wide alum. splice bar (top, bottom & back) weld to one section, #10 s.s. sht. metal screws @ other section

Alum. return

.125 clear plex alignment bar x 3" wide (cement to one face)

Individual Elements, Illuminated Laser Line Splice Detail - All Sizes

285.15.16

Individual Elements, Illuminated Laser Line Splice Detail - All Sizes 285.15.16

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Monogram "B"

285, Facility Signs Engineering Drawings 4’-0" 5’-0"

8’-0"

10’-0"

~ ~

Monogram

12’-9 5/8"

10’-2 7/8"

7’-8 1/8"

5’-1 1/2"

Height

Returns: Black

"A"

Monogram field: Black

Monogram letters/curlicues: White (when field is used)

~

10’-0"

8’-0"

6’-0"

4’-0"

"A"

Not to scale

2’-6"

2’-0"

1’-6"

1’-0"

"B"

Individual Elements, Nonilluminated Installation Elevation - Single-Line Layout

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

Monogram letters/curlicues may be fabricated and installed as individual elements without field. If so, construction and colors are the same as for letters.

Fabrication Instructions

Letters faces: Black on light bldg’s., White or alum. or steel colored on dark bldg’s.

varies

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Single-line Layout

Laser Line: GE color Laser Red face, Black returns

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3 5/8"

2 7/8"

2 1/8"

1 1/2"

Laser Line

Spacing Dimensions

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2’-0" 3’-0"

4’-0"

6’-0"

Letters

Height

Monogram

Laser Line

Letters

GE Identity Program

285.15.21

Individual Elements, Nonilluminated Installation Elevation - Single-Line Layout 285.15.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings ~ Monogram

1 1/2"

2’-0" 3’-0" 4’-0" 5’-0"

4’-0"

6’-0"

8’-0"

10’-0"

Height

14’-8 1/8"

11’-8 7/8"

8’-9 5/8"

5’-10 1/2"

"A"

10’-0"

8’-0"

6’-0"

4’-0"

2’-6"

2’-0"

1’-6"

1’-0"

"B"

Not to scale

~

Individual Elements, Nonilluminated Installation Elevation - Stacked Layout

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

Monogram letters/curlicues may be fabricated and installed as individual elements without field. If so, construction and colors are the same as for the letters.

Fabrication Instructions

Letter faces: Black on light bldg’s., White or alum. or steel colored on dark bldg’s. varies

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1’-10 1/2"

1’-6"

1’-1 1/2"

9"

"C"

Stacked Layout

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3 5/8"

2 7/8"

2 1/8"

Laser Line

Letters

Monogram

Height

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

"A" Monogram letters/curlicues: White (when ring & field are used)

Spacing Dimensions

Laser Line: GE color Laser Red face, Black returns

Returns: Black

~

Monogram

Monogram field: Black

Letters "C" Letters "B" Laser Line

GE Identity Program

285.15.22

Individual Elements, Nonilluminated Installation Elevation - Stacked Layout 285.15.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 1 1/2" 2 1/8" 2 7/8" 3 5/8"

3’-0" 4’-6" 6’-0" 7’-6"

6’-0"

8’-0"

10’-0"

6" 9" 1’-0" 1’-3"

1’-6" 2’-0" 2’-6"

7’-8 1/8"

12’-9 5/8"

10’-2 7/8"

"B"

"A" 1’-0"

Height 5’-1 1/2"

Not to scale

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

The erector shall be responsible for determining if wall conditions are adequate for letter installations and designing actual attachment. If required, additional support members to be erected prior to installation.

Installation Instructions

Monogram letters/curlicues may be fabricated and installed as individual elements without field. If so, construction and colors are the same as for letters.

Fabrication Instructions

Optional Single-line Layout

Laser Line: GE color Laser Red face, Black returns

Black returns

~

varies Letter faces: Black on light bldg’s., White, alum. or steel colored on dark bldg’s.

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Laser Line

Letters

4’-0"

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

"A"

Spacing Dimensions

~ ~

Monogram

Monogram

Height

Monogram letters/curlicues: White (when field is used)

"B" "B"

Monogram field: Black

Monogram "A" Laser Line

Individual Elements, Nonilluminated Installation Elevation Optional Single-Line Layout

Letters

GE Identity Program

285.15.23

Individual Elements, Nonilluminated Installation Elevation Optional Single-Line Layout 285.15.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings

~

1

6

25

12

2" [51]

Filler: Black, gloss finish

Face of wall

Individual Elements, Nonilluminated 4’0” Monogram Fabrication Elevations

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side View

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/4"=1’-0"

0

Front View

o

2’-0" [610]

3 3/8" [86]

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Mounting location (typ. 4 places)

Typ. stud location

Alum. channel 3 x 1 x 1/8 (typ.)

Monogram letters/curlicues: White, gloss finish

Monogram field: Black, gloss finish

45

2’-0" [610]

4’-0" [1219] dia.

2’-0" [610] 2’-0" [610]

GE Identity Program

285.15.24

Individual Elements, Nonilluminated 4’0” Monogram Fabrication Elevations 285.15.24

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 1 0

1 1/2

1/8" [3]

2" [51]

3

Inches

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.125 alum. back riveted to channel framing

Alum. bent plate: 3/16 x 1 1/2 x 3 1/2 x 4" lg. w/ 1/2" dia. lag screws or thd. stud grouted into wall

Alum. bent plate: 3/16 x 1 1/2 x 3 1/2 x 4" lg. w/ 1/2" dia. bolt, nut & washer (typ. 4 places)

1/2" dia. bolt, nut & washer

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

3" [76]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. channel: 3 x 1 x 1/8 (weld front & back)

1/4" dia. stud w/ hex nut welded to letters/curlicues (attach thru background @ locations shown)

Alum. bent plate: 3/16 x 3 x 3 (weld to channel frame & back @ mounting locations)

.250 alum. background (field) weld to channel framing

.190 alum. letters/curlicues

Alum. channel: 3 x 1 x 1/8 cont. all around

1/4" [6]

Individual Elements, Nonilluminated 4’0” Monogram Fabrication Details

285.15.25

Individual Elements, Nonilluminated 4’0” Monogram Fabrication Details 285.15.25

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

.125 alum.: paint face GE color Laser Red, gloss finish

Black returns, gloss finish

285, Facility Signs Engineering Drawings

1" [25]

3/8" [10]

Scale: Half

3/4

1 1/2

Inches

Pop rivet (typ.)

Scale: Half

3/4

1 1/2

Inches

3/8" [10] 1" [25] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

2’-0" and 3’-0" Letters

Typical Cross Section

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

White, Black, alum. or steel colored faces (gloss finish), to be determined by field survey

Fabricated letter w/ .125 alum. returns & face

.125 x 1 1/2" alum. mounting strap @ mounting points

Black returns, gloss finish

Pop rivet (typ.)

Face of wall

3/8" dia. thd. rod w/ (2) hex nuts @ approx. 18" c/c (grout into wall)

.125 x 1 1/2" alum. mounting strap @ 18" c/c

1/4" dia. thd. rod w/ (2) hex nuts @ 18" c/c (grout into wall)

Face of wall

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

1 1/2" Laser Line

Typical Cross Section

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1 1/2" [38]

GE Identity Program 3" [76]

3" [76]

Individual Elements, Nonilluminated 1 1 / 2” Laser Line & 2’0” & 3’0” Letter Fabrication Details

285.15.26

Individual Elements, Nonilluminated 1 1 / 2” Laser Line & 2’0” & 3’0” Letter Fabrication Details 285.15.26

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 12

18

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

6

Inches

3’-0" [914]

2" [51]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Face of wall

Filler: Black, gloss finish

Individual Elements, Nonilluminated 6’0” Monogram Fabrication Elevations

Side View

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

3’-0" [914]

5 3/8" [137]

~

0

28

2

6’-0" [1829] dia.

Front View

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Mounting location (typ. 4 places)

Typ. stud location

~

Alum. channel: 3 x 2 x 3/16 (typ.)

Monogram letters/curlicues: White, gloss finish

45o

3’-0" [914]

~ 3’-0" [914]

Monogram field: Black, gloss finish

~

GE Identity Program

285.15.27

Individual Elements, Nonilluminated 6’0” Monogram Fabrication Elevations 285.15.27

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

Scale: 3"=1’-0"

Section 2

5" [127]

0

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Alum. channel: 5 x 2 x 3/16 (weld front & back)

1/4" dia. stud w/ hex nut welded to letters/curlicues (attach thru background @ locations shown)

.250 alum. background (field) weld to channel framing

.190 alum. letters/curlicues

Alum. bent plate: 3/16 x 3 x 3 (weld to channel frame & back @ mounting locations)

Alum. channel: 5 x 2 x 3/16 cont. all around

1/4" [6]

3

Inches

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

.125 alum. back riveted to channel framing

Alum. bent plate: 3/16 x 1 1/2 x 3 x 4" lg. w/ 1/2" dia. lag screws or thd. stud grouted into wall

Alum. bent plate: 3/16 x 1 1/2 x 3 1/2 x 4" lg. w/ 1/2" dia. bolt, nut & washer (typ. 4 places)

1/2" dia. bolt, nut & washer

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1 1/2

1/8" [3]

2" [51]

Individual Elements, Nonilluminated 6’0” Monogram Fabrication Details

285.15.28

Individual Elements, Nonilluminated 6’0” Monogram Fabrication Details 285.15.28

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

.125 alum.: paint face GE color Laser Red, gloss finish

285, Facility Signs Engineering Drawings

5" [127]

0 3/4

1 1/2

Inches

2" [51]

3/8" [10]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: Half

2 1/8" Laser Line

Typical Cross Section

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2 1/8" [54]

GE Identity Program

Typical Cross Section

2" [51] 0

1 1/2

3

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

3'-0" and 4'-6" Letters

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

White, Black, alum. or steel colored faces (gloss finish), to be determined by field survey

Fabricated letter w/ .125 alum. returns & face

.125 x 1 1/2" alum. mounting strap @ mounting points

Black returns, gloss finish

Pop rivet (typ.)

Face of wall

3/8" dia. thd. rod w/ (2) hex nuts @ approx. 18" c/c (grout into wall)

Pop rivet (typ.)

.125 x 1 1/2" alum. mounting strap @ 18" c/c

1/4" dia. thd. rod w/ (2) hex nuts @ 18" c/c (grout into wall)

Face of wall

3/8" [10] 5" [127]

Black returns, gloss finish

Individual Elements, Nonilluminated 2 1 / 8” Laser Line & 3’0” & 4’6” Letter Fabrication Details

285.15.29

Individual Elements, Nonilluminated 2 1 / 8” Laser Line & 3’0” & 4’6” Letter Fabrication Details 285.15.29

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings Scale: 1/2"=1’-0"

6

3

12

31

18

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

~ 0

Front View

o

45 (typ.)

Inches

31

Face of wall

Filler: Black, gloss finish

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side View

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

24

4

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

C 3 x 5 (typ. ns & fs)

Mounting location (typ. 4 places)

Face splice

L: 1 1/2 x 1 1/2 x 3/16 brace (typ. 12 places)

Typ. stud location for attaching letters/curlicues to face

~

Letters/curlicues: .190 flat cut-out alum. (attach to face w/ 1/4" dia. studs as shown)

Field: Black, gloss finish

3/4" dia. eyebolt

8’-0" [2438] dia.

Individual Elements, Nonilluminated 8’0” Monogram Fabrication Elevations

285.15.30

Individual Elements, Nonilluminated 8’0” Monogram Fabrication Elevations 285.15.30

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

Scale: 1 1/2"=1’-0"

Section 3

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.250 alum. background

L: 1 1/2 x 1 1/2 x 3/16 frame

.190 alum. letters/curlicues

L: 1 1/2 x 1 1/2 x 3/16 frame cont. all around (typ.)

C 3 x 5 (top only)

1/4" dia. stud w/ hex nut welded to background & attached thru angle frame @ 18" c/c

#10- type F flat hd. csk. screws @ 18" c/c (typ.)

3/16" [5]

1/4" [6]

3

6

2" [51]

Inches

Scale: 1 1/2"=1’-0"

Section 4

#10- type F flat hd. csk. selftapping screw @ 18" c/c

C3x5

1/4" dia. stud w/ hex nut (weld stud @ locations shown & attach to background)

.190 flat cut-out letters/ curlicues

.250 alum. background (field)

Face splice

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 alum. back (pop rivet to "L" frame @ 18" c/c)

Bent plate: 3/16 x 3 x 1 1/2 x 4" lg. (bolt to C 3 x 5 w/ 1/2" dia. bolt, nut & washer)

Bent plate: 3/16 x 1 1/2 x 2 1/2 w/ 1/2" dia. lag bolt or thd. stud grouted into wall

1/2" dia. hex bolt, nut & washer

.125 alum. filler: paint Black, gloss finish

3/4" dia. eyebolt for liftingremove after installation & replace w/ 3/4" rd. hd. screw (weld nut inside channel)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

8" [203]

3

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

Individual Elements, Nonilluminated 8’0” Monogram Fabrication Details

285.15.31

Individual Elements, Nonilluminated 8’0” Monogram Fabrication Details 285.15.31

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

.125 alum.: paint face GE color Laser Red gloss finish

Black returns, gloss finish

285, Facility Signs Engineering Drawings

2 1/2" [64]

Scale: 3"=1’-0"

1 1/2

3

Inches

3/8" [10]

1 1/2" [38]

Scale: 3"=1’-0"

1 1/2

3

Inches

3/8" [10] 2 1/2" [64] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

4'-0" and 6'-0" Letters

Typical Cross Section

1 1/2" [38]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

White, Black, alum. or steel colored faces (gloss finish) to be determined by field survey

.190 x 2" alum. mounting strap @ mounting points

Black returns, gloss finish

Fabricated alum. letters w/ .190 returns & face

3/16" dia. pop rivets (typ.)

(2) 3/8" dia. thd. rod w/ dbl. hex nuts @ approx. 24" c/c (grout to wall)

Face of wall

Pop rivet (typ.)

Face of wall

3/8" dia. thd. rod w/ (2) hex nuts @ 18" c/c (grout into wall)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

2 7/8" Laser Line

Typical Cross Section

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.125 x 2" alum. mounting strap @ 24" c/c

2 7/8" [73]

GE Identity Program 6" [152]

6" [152]

Individual Elements, Nonilluminated 2 7 / 8” Laser Line & 4’0” & 6’0” Letter Fabrication Details

285.15.32

Individual Elements, Nonilluminated 2 7 / 8” Laser Line & 4’0” & 6’0” Letter Fabrication Details 285.15.32

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings Scale: 3/8"=1’-0"

12

24

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

~ 0

34

5

10’-0" [3048] dia.

Front View

45 (typ.)

o

3/4" eyebolt

34

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

6

10" [254]

2" [51]

Filler: Black, gloss finish

Face of wall

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Side View

3/16" [5]

1/4" [6]

Individual Elements, Nonilluminated 10’0” Monogram Fabrication Elevations

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

C 3 x 5 (typ. ns & fs)

Face splice

Location of typ. wall bracket

L: 1 1/2 x 1 1/2 x 3/16 brace (typ. 12 places)

Letters/curlicues: paint White (attach to background w/ studs located as shown)

Typ. stud location

Field: paint Black, gloss finish

~

GE Identity Program

285.15.33

Individual Elements, Nonilluminated 10’0” Monogram Fabrication Elevations 285.15.33

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

GE Identity Program

285, Facility Signs Engineering Drawings

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

0

10" [254]

3

6

Inches

2" [51]

0

3

6

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 6

#10- type F flat hd. csk. selftapping screw @ 18" c/c

C3x5

1/4" dia. stud & hex nut (weld stud to letters/curlicues & drill background @ locations shown)

.190 alum. letters/curlicues

.250 alum. background (field)

Face splice

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

.125 alum. back (pop rivet to "L" frame @ 18" c/c)

Bent plate: 3/16 x 3 x 1 1/2 x 4" lg. (bolt to C 3 x 5 w/ 1/2" dia. bolt, nut & washer)

Bent plate: 3/16 x 1 1/2 x 2 1/2 w/ 1/2" dia. lag bolt or thd. stud grouted into wall

1/2" dia. hex bolt, nut & washer

.125 alum. filler: paint Black, gloss finish

3/4" dia. eyebolt for liftingremove after installation & replace w/ 3/4" rd. hd. screw (weld nut inside channel)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1 1/2"=1’-0"

Section 5

.250 alum. background (field)

L: 1 1/2 x 1 1/2 x 3/16 dbl. angle frame

.190 alum. letters/curlicues

L: 1 1/2 x 1 1/2 x 3/16 frame cont. all around (typ.)

C 3 x 5 (top only)

1/4" dia. stud w/ hex nut welded to background & attached thru angle frame @ 18" c/c

#10- type F flat hd. csk. screws @ 18" c/c (typ.)

3/16" [5]

1/4" [6]

Individual Elements, Nonilluminated 10’0” Monogram Fabrication Details

285.15.34

Individual Elements, Nonilluminated 10’0” Monogram Fabrication Details 285.15.34

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

.125 alum.: paint face GE color Laser Red, gloss finish

285, Facility Signs Engineering Drawings

8" [203] 3" [76]

Scale: 3"=1’-0"

1 1/2

3

Inches

3/8" [10]

Faces: White, Black, alum. or steel colored (gloss finish) to be determined by field survey

Fabricated letter w/ .190 alum. returns & face

Black returns, gloss finish

.190 x 2" alum. mounting strap @ mounting points

(2) 3/8" dia. thd. rods w/ dbl. hex nuts @ approx. 24" c/c (grout into wall)

3/16" dia. pop rivet(typ.)

Face of wall

Typical Cross Section

1 1/2" [38]

Scale: 3"=1’-0"

1 1/2

3

Inches

3/8" [10] 3" [76] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

5’-0" and 7’-6" Letters

1 1/2" [38]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Pop rivet (typ.)

Face of wall

3/8" dia. thd. rod w/ (2) hex nuts @ 18" c/c (grout into wall)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

3 5/8" Laser Line

Typical Cross Section

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

.125 x 2" alum. mounting strap @ 18" c/c

3 5/8" [92]

GE Identity Program 8" [203]

Black returns, gloss finish

Individual Elements, Nonilluminated 3 5 / 8” Laser Line & 5’0” & 7’6” Letter Fabrication Details

285.15.35

Individual Elements, Nonilluminated 3 5 / 8” Laser Line & 5’0” & 7’6” Letter Fabrication Details 285.15.35

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Visitors Lot 2 Lot 3 Shipping

g

5 1/2" [140]

0

6

12

1

18

24

4’-8" [1422] min., 7’-8" [2337] max. mounting height

~ Filler: GE color G 02 C Grey, matte finish

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Single-face Instructions If this sign is used as a single-faced sign, construct the same as detailed and eliminate graphics at one face (face to be GE color G 02 C Grey, opaque).

Side Elevation

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

1’-6" [457] typ.

4" typ. [102]

03

2 3/4" [70]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/2"=1’-0"

Front Elevation

~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 4 x 4 x 3/16 column (typ.)

Non-reinforced concrete caisson (typ.) estimated quantity of concrete = 1.6 cu. yds.

Finish grade

Paint columns & beam GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Face: GE color G 02 C Grey opaque, matte finish

Graphics & arrows: Black film, matte finish

Laser Line: film to match GE color Laser Red

Monogram letters/curlicues: White Scotchcal 3680-20 or equal

Monogram field: Black, matte finish

2 3/4" [70]

4’-0" [1219]

3/16" [5] 2 5/32" [55] 2 5/32" [55]

1 3/8" [35] 5 1/2" [140] 2 3/4" typ. 1 3/8" [70] [35] 2 3/4" typ. [70]

8 1/4" [210] 3/4" 1’-11 9/16" [598] [19] 2" [51]

2’-8" [813] 2’-0" [610] min., 5’-0" [1524] max. 3" typ. [76]

285, Facility Signs Engineering Drawings 6" [152]

GE Identity Program

~ 3’-0" [914]

Directional Sign, D-3 Sign Elevation & Installation Drawing

285.21.01

Directional Sign, D-3 Sign Elevation & Installation Drawing 285.21.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2 03

Scale: 1/2"=1’-0"

0

1 03

12

18

24

Inches

angle to filler

2’-8" [813]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

6

4" [102]

1/2" typ. [13]

1’-0" [305]

2’-0" [610]

4 1/4" typ. [108]

2’-0" [610]

Front View

1’-0" [305]

2’-0" [610]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Mounting bolt installation access holes as req’d.

TS: 4 x 4 x 3/16 column (typ.)

TS: 2 x 4 x 3/16 beam

Alum. angle: 2 x 2 x 3/16 x 2 1/2" lg. (typ. lower corners)

3/4" dia. bolt (4-req’d.)

TS: 2 x 2 x 3/16 (typ.)

TS: 2 x 2 x 3/16 @ top

Alum. angle: 2 x 2 x 3/16 (typ. each end)

See Detail A, sheet 03

Extruded alum. filler #GE-115

3/8" dia. eyebolt for lifting (replace w/ 3/8" dia. rd. hd. bolt after installation)

4’-0" [1219]

3/4" [19] 2" [51]

285, Facility Signs Engineering Drawings 2’-0" [610] min., 5’-0" [1524] max.

Directional Sign, D-3 Fabrication Drawing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

4’-8" [1422] min., 7’-8" [2337] max. mounting height

GE Identity Program

285.21.02

Directional Sign, D-3 Fabrication Drawing 285.21.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1/8" [3]

1/8" [3]

Scale: 3"=1’-0"

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

cont., typ.

12 ga. end cover plate, weld in place all around & grind smooth (typ. each end)

Provide weep holes as req’d.

0 1 1/2

2" [51]

3

Inches

Scale: 3"=1’-0"

Detail A

Alum. angle: 2 x 2 x 3/16

Extruded alum. filler

1/2" dia. A325 corrosion resistant bolt, nut & washer (1 each end)

TS: 2 x 2 x 3/16 (miter each end for bolt placement)

Scale: 3"=1’-0"

Section 2

.250 Lexan face

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

Extruded alum. filler #GE-115

.315 Lexan lug, cont.cement to face (typ. each end)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Holes in t & b of beam as req’d. for bolt installation

TS: 4 x 4 x 3/16 column

TS: 2 x 4 x 3/16 beam

C 3 x 4.1 reveal (cut legs back to 3/4") or 10 ga. fabricated

Plate: 1/8 x 2 1/2 x 2 1/2 welded to 3/4" plate (typ. 2 places)

(2) 3/16" dia. csk. rivets (filler to 1/8" plate) typ.

Plate: 3/4 x 2 3/4 x 6 @ each vertical

3/4" dia. s.s. A325 bolt & nut (weld nut inside signbox) 4-req’d. total

.250 Lexan face (typ.)

TS: 2 x 2 x 3/16 vertical

.315 Lexan lug, cont.: cement to face (typ. top & bottom)

TS: 2 x 2 x 3/16 @ top

Extruded alum. filler #GE-115, attach top section w/ (2) #10 flat hd. csk. thd. cutting screws @ 18" c/c

3/8" dia. shoulder pattern eyebolt for lifting (weld nut inside tube)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/16"

1/8" [3]

~

1/8"

3/16" [5]

2" [51]

4" [102]

3/4" [19]

cont.

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

3/4" [19] 5/8" [16]

1/16" [2] 1/2" 3/4" [13] [19]

285, Facility Signs Engineering Drawings

~

GE Identity Program 1 1/2

1" [25]

1 1/2

1/16" [2]

1/16" [2]

3/4" [19]

3

3

Inches

Inches

1/8" [3]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

0

5/8" [16]

3/16" [5] 1/4" [6]

Directional Sign, D-3 Fabrication Details

285.21.03

Directional Sign, D-3 Fabrication Details 285.21.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1 13

0

12

24

4" typ. [102]

4" [102]

Filler: GE color G 02 C Grey, matte finish

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Single-face Instructions If this sign is used as a single-faced sign, construct the same as detailed and eliminate graphics at one face (face to be GE color G 02 C Grey, opaque).

Side Elevation

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

2’-0" dia. [610]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3/8"=1’-0"

Front Elevation

Visitors Lot 2 Lot 3 Shipping

g ~

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 4 x 4 x 3/16 column (typ.)

Non-reinforced concrete caisson (typ.) estimated concrete quantity = 3.7 cu. yds.

Finished grade

Paint columns & beam: GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Graphics & arrows: Black film, matte finish

Face: GE color G 02 C Grey opaque, matte finish

Laser Line: film to match GE color Laser Red

Monogram letters/curlicues: White Scotchcal 3680-20 or equal

Monogram field: Black, matte finish

4" [102]

3 7/8" 1/4" [98] [6] 4" typ. [102] 3 7/8" [98]

2" [51] 8" [203] 2" [51] 4" typ. [102] 2" [51]

1’-0" [305] 2’-11 3/4" [908] 3/4" [19]

8" [203]

4’-0" [1219] 2’-0" [610] min.

4" [102]

6’-0" [1829]

5’-0" [1524] max. 6’-0" [1829] min., 9’-0" [2743] max. mounting height 3" [76]

285, Facility Signs Engineering Drawings 6" [152]

GE Identity Program

~

4’-0" [1219]

Directional Sign, D-4 Sign Elevation & Installation Drawing

285.21.11

Directional Sign, D-4 Sign Elevation & Installation Drawing 285.21.11

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

2 13

1’-0" [305]

Scale: 1/2"=1’-0"

12

18

13

1

1’-0" [305]

24

Inches

4 1/4" typ. [108]

3’-0" [914]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

0

6

4’-0" [1219]

Front View

3’-0" [914]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

TS: 4 x 4 x 3/16 column (typ.)

Mounting bolt installation access holes as req’d.

TS: 2 x 4 x 3/16 beam

Alum. angle 2 x 2 x 3/16 x 2 1/2" lg. (typ @ lower corners)

3/4" A325 bolt location (4-req’d. total)

TS: 2 x 2 x 3/16 vertical (typ.)

TS: 2 x 2 x 3/16 top only

Alum. angle: 2 x 2 x 3/16 x 2 1/2" lg. (typ. each end)

See Detail A, sheet 13

Extruded alum. filler #GE-115

3/8" eyebolt for lifting (replace w/ 3/8" dia. rd. hd. mach. screw after installation)

angle to filler 3/4" [19]

4’-0" [1219]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

2" [51]

285, Facility Signs Engineering Drawings 2’-0" [610] min. 5’-0" [1524] max.

6’-0" [1829]

Directional Sign, D-4 Fabrication Drawing

6’-0" [1829] min., 9’-0" max. mounting height

GE Identity Program

285.21.12

Directional Sign, D-4 Fabrication Drawing 285.21.12

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

3/32" [2] 3/32" [2]

Scale: 3"=1’-0"

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

cont., typ.

12 ga. end cover plate, weld in place all around & grind smooth (typ. each end)

Provide weep holes as req’d.

0 1 1/2

2" [51]

3

Inches

Scale: 3"=1’-0"

Detail A

Alum. angle: 2 x 2 x 3/16

Extruded alum. filler

1/2" dia. A325 corrosion resistant bolt, nut & washer (1 each end)

TS: 2 x 2 x 3/16 (miter each end for bolt placement)

Scale: 3"=1’-0"

Section 2

.250 Lexan face

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

Extruded alum. filler #GE-115

.315 Lexan lug, cont.cement to face (typ. each end)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Holes in t & b of beam as req’d. for bolt installation

TS: 4 x 4 x 3/16 column

TS: 2 x 4 x 3/16 beam

C 3 x 4.1 reveal (cut legs back to 3/4") or 10 ga. fabricated

Plate: 1/8 x 2 1/2 x 2 1/2 welded to 3/4" plate (typ. 2 places)

(2) 3/16" dia. csk. rivets (filler to 1/8" plate) typ.

Plate: 3/4 x 2 3/4 x 6 @ each vertical

3/4" dia. s.s. A325 bolt & nut (weld nut inside signbox) 4-req’d. total

.250 Lexan face (typ.)

TS: 2 x 2 x 3/16 vertical

.315 Lexan lug, cont.: cement to face (typ. top & bottom)

TS: 2 x 2 x 3/16 @ top

Extruded alum. filler #GE-115, attach top section w/ (2) #10 flat hd. csk. thd. cutting screws @ 18" c/c

3/8" dia. shoulder pattern eyebolt for lifting (weld nut inside tube)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3/16"

1/8" [3]

~

1/8"

3/16" [5]

2" [51]

4" [102]

3/4" [19]

cont.

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

3/4" [19] 5/8" [16]

1/16" [2] 1/2" 3/4" [13][19]

285, Facility Signs Engineering Drawings

~

GE Identity Program 1 1/2

1" [25]

1 1/2

3/32" [2]

3/32" [2]

3/4" [19]

3

3

Inches

Inches

1/8" [3]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

0

5/8" [16]

3/16" [5] 1/4" [6]

Directional Sign, D-4 Fabrication Details

285.21.13

Directional Sign, D-4 Fabrication Details 285.21.13

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 6 x 6 x 3/16 column (typ.)

Non-reinforced concrete caisson (typ.) estimated concrete quantity = 4.9 cu. yds.

Finished grade

Columns & beam: paint GE color G 03 C Grey

Reveal: GE color G 03 C Grey

Face: GE color G 02 C Grey opaque, matte finish

Graphics & arrows: Black film, matte finish

Laser Line: film to match GE color Laser Red

Monogram letters/curlicues: White Scotchcal 3680-20 or equal

Monogram field: Black, matte finish

0

12

24

1

36

23

48

6" [152]

6" [152]

8’-0" [2438] min., 11’-0" [3353] max. mounting height

3/8" 1’-6" [10] [457]

~

6" [152]

Filler: GE color G 02 C Grey, matte finish

Directional Sign, D-6 Sign Elevation & Installation Drawing

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Single-face Instructions If this sign is used as a single-faced sign, construct the same as detailed and eliminate graphics at one face (face to be GE color G 02 C Grey, opaque).

Side Elevation

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Inches

2’-0" dia. [610] (typ.)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 1/4"=1’-0"

Front Elevation

Visitors Lot 2 Lot 3 ~ Shipping

g

1’-0" [305]

5 13/16" [148] 5 13/16" [148]

3" [76] 1’-0" [305] 3" [76] 6" typ. [152] 6" typ. [152]

6" [152]

9’-0" [2743]

5’-3" [1600]

4’-5 5/8" [1362] 3" 1" [76] [25] 3" [76]

6’-0" [1829] 2’-0" [610] min. 5’-0" [1524] max.

285, Facility Signs Engineering Drawings 6" [152]

GE Identity Program

285.21.21

Directional Sign, D-6 Sign Elevation & Installation Drawing 285.21.21

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

TS: 6 x 6 x 3/16 column (typ.)

TS: 3 x 6 x 3/16 beam

2 23

1’-6" [457]

Scale: 3/8"=1’-0"

0

Front View

4’-6" [1372] 1

24

23

Inches

3 3/4" typ. [95]

4’-6" [1372]

1’-6" [457]

6" [152]

3/4" [19]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

12

6’-0" [1829]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Mounting bolt installation access holes as req’d.

Plate: 1/8 x 2 x 3 1/2 (typ.)

Alum. angle: 2 x 2 x 3/16 x 4 1/2" 1/2" lg. (typ. @ lower corners)

5/8" dia. A325 bolt & nut location (8-req’d. total)

TS: 3 x 2 x 3/16 vertical (typ.)

TS: 3 x 2 x 3/16 @ top

Alum. angle: 2 x 2 x 3/16 x 4 1/2" lg. (typ. each end)

See Detail A, sheet 23

Extruded alum. filler #GE-114

3/8" dia. eyebolt for lifting (replace w/ 3/8" rd. hd. mach. screw after installation)

6’-0" [1829] angle to filler 1" [25]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

3" [76]

285, Facility Signs Engineering Drawings 2’-0" [610] min., 5’-0" [1524] max.

9’-0" [2743]

Directional Sign, D-6 Fabrication Drawing

8’-0" [2438] min., 11’-0" [3353] max. mounting height

GE Identity Program

285.21.22

Directional Sign, D-6 Fabrication Drawing 285.21.22

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1/8" [3]

1/8"

3/16"

1/8" [3]

Scale: 3"=1’-0"

Section 1

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

cont., typ.

12 ga. end cover plate, weld in place all around & grind smooth (typ. each end)

cont.

1" [25]

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

3/16" [5]

1/8" [3]

3/4" [19] 5/8" [16]

1/16" [2] 3/4" 3/4" [19] [19]

3" [76]

~

285, Facility Signs Engineering Drawings

~

GE Identity Program 1 1/2

3" [76]

3

Inches

0

0

1 1/2

1" [25]

1 1/2

1/8" [3]

1/8" [3]

3/4" 3/4" [19] [19]

3

3

Inches

Inches

1/8" [3]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

Scale: 3"=1’-0"

Detail A

Alum. angle: 2 x 2 x 3/16

Extruded alum. filler

1/2" dia. A325 corrosion resistant bolt, nut & washer (1 each end)

TS: 3 x 2 x 3/16 (miter each end for bolt placement)

Scale: 3"=1’-0"

Section 2

.250 Lexan face

#6 x 7/16" type BF thd. cutting screw w/ flat csk. hd. @ 12" c/c (typ.)

Extruded alum. filler #GE-114

.315 Lexan lug, cont.: cement to face (typ. each end)

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

Holes in t & b of beam as req’d. for bolt installation

TS: 6 x 6 x 3/16 column

TS: 3 x 6 x 3/16 beam

Fabricated 10 ga. channel reveal

Provide weep holes as req’d

Plate: 1/8 x 2 x 3 1/2 welded to 3/4" plate (typ. 2 places)

(2) 3/16" dia. csk. rivets (filler to 1/8" plate) typ.

Plate: 3/4 x 4 x 6 @ each vertical

5/8" dia. s.s. A325 bolt & nut (weld nut inside signbox) 8-req’d. total

.250 Lexan face (typ.)

TS: 3 x 2 x 3/16 vertical

.315 Lexan lug, cont.: cement to face (typ. top & bottom)

TS: 3 x 2 x 3/16 @ top only

Extruded alum. filler #GE-114, attach top section w/ (2) #10 flat hd. csk. thd. cutting screws @ 18" c/c

3/8" dia. shoulder pattern eyebolt for lifting (weld nut inside tube)

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

0

4 1/2" [114]

2" [51]

6" [152]

3/16" [5] 1/4" [6]

Directional Sign, D-6 Fabrication Details

285.21.23

Directional Sign, D-6 Fabrication Details 285.21.23

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

0.156 [4]

0.438 0.750 [11] [19]

3/4

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1 1/2

0 3/4

(Weight = 3.35 lbs./ft.)

Scale: Half

GE-111 Filler

2.625 [67]

12.000 [305]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Weight = 0.89 lbs./ft.)

Scale: Half

0

Inches

0.875 0.125 1.063 0.125 0.688 [22] [3] [27] [3] [17]

2.875 [73]

3.094 [79]

GE-112 Retainer

0.125 [3]

0.125 [3]

0.090 [2]

4.875 [124]

0.090 [2]

0.875 0.250 [22] [6]

0.125 [3]

1.250 [32]

0.125 [3]

285, Facility Signs Engineering Drawings 1.410 [36]

0.156 [4] 1.500 [38]

GE Identity Program Inches

0.156 [4]

0.125 [3]

1.000 [25]

3.094 [79]

0

3/4

(Weight = 0.319 lbs./ft.)

Scale: Half

0.125 [3]

Inches

0.625 0.750 0.125 [16] [19] [3] 1.500 [38] Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

1 1/2

0.090 [2]

0.125 [3]

0.125 [3]

0.250 0.875 [6] [22]

GE-113 T-Bar

0.500 0.500 [13] [13]

The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1 1/2

2.625 [67]

4.875 [124]

1.125 [29]

Extrusions GE-111, GE-112, & GE-113 Extrusion Details

285.30.01

Extrusions GE-111, GE-112, & GE-113 Extrusion Details 285.30.01

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

285, Facility Signs Engineering Drawings 3/4

4.000 [102]

(Weight = 1.165 lbs./ft.)

Scale: Half

0

GE-114 Filler

0 3/4

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

1 1/2

Inches

0.313 [8]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Weight = 0.937 lbs./ft.)

Scale: Half

Inches

0.125 0.406 [3] [10]

1 1/2

0.125 [3]

0.125 [3]

5.125 [130]

3.195 [81]

4.000 [102]

0

3/4

1.000 [25] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1 1/2

Inches

0.090 0.313 [2] [8]

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Weight = 0.735 lbs./ft.)

Scale: Half

GE-115 Filler

0.313 0.090 [8] [2]

0.125 [3]

6.000 [152]

GE-116 Retainer

0.125 [3]

0.125 [3]

0.500 [13] 1.750 [44]

0.313 [8] 0.125 [3]

Extrusions GE-114, GE-115, & GE-116 Extrusion Details

0.750 [19]

GE Identity Program

285.30.02

Extrusions GE-114, GE-115, & GE-116 Extrusion Details 285.30.02

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

1

3.875 [98]

30 typ.

o

o

30 typ.

3/4

1 1/2

Inches

0.188 [5]

0 3/4

1 1/2

Inches

1.000 [25] 1.000 [25]

0.906 0.188 0.906 [23] [5] [23]

to others for any purpose except as specifically authorized in writing by General Electric Company. Questions regarding the contents herein shall be directed to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Weight = 0.206 lbs./ft.)

Scale: Half

GE-119 Retainer Clip

0.125 [3]

1.000 [25]

(Weight = 2.442 lbs./ft.)

Scale: Half

0

GE-117 Retainer

]

[51

The registered service mark, design, and specifications as set forth herein are proprietary and are the exclusive property of General Electric Company. Neither this document nor the information disclosed herein may be reproduced, changed, altered, transferred to other documents, used for manufacturing purposes, nor disclosed

00

2.0

25 0.6 ] [16 ] 38 0[ .50

0.500 [13]

285, Facility Signs Engineering Drawings 0.125 [3]

0.125 [3] 0.125 0.281 0.125 [3] [7] [3]

0.688 [17]

0.938 [24]

0.188 [5]

0.875 [22]

o

30

0

3/4

0.531 0.125 [13] [3]

2.000 [51] The sign manufacturer acknowledges by using these plans and corresponding specifications that he understands all conditions, requirements, policies, and procedures related to the use of these drawings in the manufacture and erection of this sign.

1 1/2

Inches

Upon completion, termination, or expiration of the Sign Manufacturer’s contract, or agreement for other authorized use held by the sign manufacturer with General Electric Company, all plans, color charts, schematics, wiring diagrams, and specifications shall be returned to General Electric Company, 3135 Easton Turnpike, Fairfield, Connecticut 06431.

(Weight = 1.050 lbs./ft.)

Scale: Half

GE-118 Retainer

0.125 [3]

0.125 [3]

1.875 [48] 0.156 [4] 0.125 [3]

0.188 [5] 0.125 [3]

GE Identity Program 25 0.1 ] [3

0.125 [3]

12 0.3 ] 4 [8 9 0.0 [2]

1.219 [31]

0.125 [3]

Extrusions GE-117, GE-118, & GE-119 Extrusion Details

285.30.03

Extrusions GE-117, GE-118, & GE-119 Extrusion Details 285.30.03

GE Identity Website: http://www.ge.com/identity GE Identity Hotline: 800 654-2696 or 518 869-2824 (DC: 232-2696)

Related Documents

Drawings
May 2020 21
Ge
November 2019 50
Ge
October 2019 55