PRESENTASI
APKABEL
( Asosiasi Pabrik Kabel Indonesia)
KABEL WAJIB PEMBERLAKUAN WAJIB SNI
PERALATAN LISTRIK UNTUK TERWUJUDNYA KESELAMATAN INSTALASI LISTRIK Hotel SARI PACIFIC - Jakarta, 05 Des 2018
Address
: Komplek Ketapang Indah Blok B2 No. 32, Jalan Zainul Arifin. Jakarta – 11140, INDONESIA Phone : (62-21) 634.1113, 634.1036 Facsimile : (62-21) 633.3032 Email :
[email protected] Established on : 10 Februari 1973 by 5 founding members First Cable Factory : Since 1962 Member of : • Indonesian Chamber of Commerce and Industry (KADIN) • Indonesian Infocom Society (MASTEL) • Asian Wire & Cable Cooperation Aliance (AWCCA) Under Supervision & Coordination : . Indonesian Ministry of Industry . Indonesian Ministry of Trade . Indonesian Ministry of Energie and Mineral Resources . Indonesian Ministry of Information and Communication
BOARD OF ADVISORY (Dewan Pengawas)
Chief Advisor Members of Advisors Cable Tbk.
: - Mr. Muhamad Ikbal Bey PT. Prima Cable Indo. : - Mr. Marcello T Taufik PT. KMI Wire and - Mr. M Willy Manoppo - Mr. Robert Lordianto - Ms. Corry Juwanta
PT. Multico PT. Prima Indah Lestari PT. Ewindo.
BOARD OF MANAGEMENT (Dewan Pengurus)
Chairman / Ketua Umum : Mr. Noval Jamalullail General Secretary / Sekjen : Mr. Denny Simorangkir PT. Magna Kabel Nusantara Treasurer / Bendahara : Mr. Lidya Santoso PT. BICC Berca Power Cable Department Head : Mr. Dede Suhendra PT. KMI Wire and Cable Tbk Telecommunication Cable Department Head : Mr. Akmal Fauzi PT. Voksel Electric Tbk.
ANGGOTA APKABEL DATA 10 TAHUN TERAKHIR
URAIAN
2007
2008
31
JUMLAH ANGGOTA APKABEL
Terdiri dari : 1. Kabel Listrik = 2. Kabel Telekomunikasi =
32
52 13
2009
2010
33
2011
2012
Nov 2018
36
Estimasi Anggota Akhir 2018 : 61 pabrik (+ 2 anggota baru)
39
2018
46
59
K
SEMINAR SOSIALISASI SEMINAR SOSIALISASI
DATAKESELAMATAN JUMLAH PABRIK KABEL KELISTRIKAN KESELAMATAN KELISTRIKAN BERDASARKAN PRODUK HOTELINT’L KAISAR -JENIS JAKARTA, MEI 2010 EMERALD GARDEN HOTEL - MEDAN,11 14 APRIL2010
DATA JUMLAH PABRIK BERDASARKAN PRODUK * Low Voltage Cable for Al * Low Voltage Cable for Cu * Building Wire Cable for Cu * Med Voltage Cable (Al & Cu) * High Voltage Conductor (Al) * High Voltage UG Cable 150kV * Telecommunication Cu Cable * Fiber Optic Cable * Special Cable
: : : : : : : : :
23 35 45 11 21 8 2 11 12
pabrik pabrik pabrik pabrik pabrik pabrik pabrik pabrik pabrik
PRODUK UMUM KABEL A. KABEL TELEKOMUNIKASI : 1. Copper (Cu) Telephone Cable 2. Fiber Optic Cable B. KABEL LISTRIK : 1. Bare Conductor 2. Building Wire
3. Low Voltage Cable 4. Medium Voltage Cable 5. High Voltage Cable
(1-500 KV) (300-750 V)
(0,3 -- 1 KV) (3 – 36 KV) (40—500 KV)
OUTPUT PRODUCTION PROCESS
BARE CONDUCTOR General Cable Procesing
Bare Conductor
Power Cable
TYPE DAN PRODUK Industry Kabel di Indonesia Telecommunication Cable
Aerial, Duct & Direct Buried Type Of Cu Telephone and Fiber Optic Cable
STRUKTUR MATERIAL KABEL STRUKTUR UTAMA KABEL : * * * *
KONDUKTOR (Cu, Al, Cu Tin & Fiber) (PVC, PE, XLPE & Rubber) ISOLASI PELINDUNG (Steel, Al, Cu & Lead) JACKET/SHEAT (PVC, PE, HDPE, XLPE & Rubber)
SECARA UMUM PELINDUNG ADA 2 :
1. Pelindung Elektris : Cu Wire / Tape, Al Tape & Tin Cu Wire 2. Pelindung Mekanis : Steel Wire / Tape / Flat / Corrugated / Al
JENIS & TEGANGAN KABEL JENIS BERDASARKAN STRUKTUR
:
* Single Core Isolasi (Cu/PVC, Cu/PVC/PVC) * Multi Core Isolasi (Cu/PVC/PVC, Cu/PVC/DSTA) * Bare Cable / Non Isolasi (BCC, AAAC, ACSR)
PEMBAGIAN BERDASARKAN TEGANGAN :
* Tegangan Rendah / LV (400 V – 1000 V) Cu/PVC, Cu/PVC/PVC, NFA2X-T * Tegangan Menengah / MV (3,6 KV – 33 KV) N2XSY, N2XSEBY, NA2XSEYBY, AAACS * Tegangan Tinggi / HV (40 KV – 500 KV) NA2XSEY, ACSR, T-ACSR , dll
TEMU KOMUNIKASI SIFAT2 KONDUKTOR KABEL 2007 BIRAWA ASSEMBLY, BIDAKARA - JAKARTA, 9 Juli 2007
NO
JENIS KONDUKTOR
SIFAT KONDUKSI
TAHANAN KONDUKTOR
MEDAN ELECTRO & PANAS
1
TEMBAGA / Cu
Sangat Baik
Sangat Kecil
Sangat Besar
2
Tin Copper / Tin Cu
Sangat Baik
Sangat Kecil
Sangat Besar
3
ALUMINIUM / Al
Sedang
Sedang
Sedang
Tidak Ada
Tidak Ada
4
FIBER OPTIC / FO
Tidak
TEMU KOMUNIKASI SIFAT-SIFAT ISOLASI KABEL 2007
BIRAWA ASSEMBLY, BIDAKARA - JAKARTA, 9 Juli 2007
SIFAT BAHAN
TAHANAN ISOLASI
PVC 1 Poly Vinyl Chloride
Cukup Lentur
Kecil / Krg Baik
RAMBAT PANAS / API Kecil / Flame
PE 2 Poly Ethylene
Agak Keras
Sgt Besar / Sgt Baik
Sangat Besar
XLPE ( Cross Link 3 Poly Ethylene )
Agak Keras
Besar / Baik
Besar
Sangat Lentur
Kecil / Krg Baik
Besar
NO
JENIS BAHAN ISOLASI / SHEAT
Rubber 4
SIMPLE POWER CABLE INTRODUCTION & PROCESS General Cable Procesing 2
1
3
4
5
6
7
No
Process
Uraian
1
Drawing
Proses menarik & Draw Cu Rod / Konduktor
2
Stranding
Proses Penggabungan / Pilinan Wire Konduktor
3
Insulation
Proses Extrusi, Melapisi atau Menutupi Konduktor
4
Cabling
Proses Pilinan Beberapa Konduktor Berisolasi
5
Inner Sheath
Proses Pembungkusan / Selubung Kabel Dalam
6
Armouring
Proses Selubung/Covering dengan Pelindung Mekanis
7
Outer Sheath
Proses Pembungkusan / Selubung Kabel Luar
8
Final Test
Visual, Dimension, AC test voltage, Conductor Resistance, Insulation resistance
8
GENERAL CABLE CONSTRUCTION
ARMOURING CABLE General Cable Procesing
BUILDING WIRE Supreme Cable Manufacturing Corporation
Cu/PVC/PVC (NYM) 300/500 Volt Copper PVC Insulation PVC Outer Sheath
LOW VOLTAGE POWER CABLE (Up to 1 kV) Supreme Cable Manufacturing Corporation
Cu/PVC/PVC (NYY) Copper PVC Insulation PVC Inner Sheath PVC Outer Sheathed
MEDIUM VOLTAGE POWER CABLE (3 kV up to 45 kV) Supreme Cable Manufacturing Corporation
Cu/XLPE/CTS/PVC Copper (N2XSEY) XLPE Insulation Copper Tape Screen PVC Outer Sheath
Single Core
Multi Core
RUJUKAN PERATURAN SNI KABEL WAJIB DASAR RUJUKAN PERATURAN “SNI KABEL WAJIB” : * PERATURAN MENPERIN No : 42/M-IND/PER/3/2010 No : 50/M-IND/PER/5/2011 No : 57/M-IND/PER/5/2012 No : 84/M-IND/PER/10/2014 No : 06/M-IND/PER/2/2017
(29/03/2010) ( 09/05/2011) (09/05/2012) (02/10/2014) (Feb 2017)
* PERATURAN DIRJEN BASIS INDUSTRI MANUFAKTUR (JUKNIS) No : 02/BIM/PER/11/2010 (25/11/2010) No : 10/BIM/PER/8/2011 (16/08/2011) No : 05/BIM/PER/1/2015 (05/01/2015)
URAIAN PERMENPERIN 84 SNI KABEL WAJIB (2014) RUANG LINGKUP PEMBERLAKUAN “SNI WAJIB KABEL” ex 8544.11.10.00 kabel berinti tunggal berbentuk padat atau dipilin atau
1
fleksibel; berpenghantar tembaga polos atau dilapis atau berisolasi PVC (Polyvinyl Chloride); dengan tegangan pengenal sampai dengan 450/750 V, tanpa selubung luar (nirselubung) untuk instalasi tetap tidak bergerak (perkawatan magun); dengan atau tanpa konektor.
SNI 04.6629.3-2006
ex ex ex ex ex ex ex ex ex
8544.11.20.00 8544.11.90.10 8544.11.90.20 8544.11.90.90 8544.42.91.00 8544.42.92.00 8544.49.22.00 8544.49.23.00 8544.49.41.00
2
2
kabel multi inti berbentuk padat atau dipilin berpenghantar tembaga polos atau dilapis dan atau berisolasi PVC (Polyvinyl Chloride) dengan tegangan pengenal sampai dengan 450/750 v, berselubung untuk instalasi tetap tidak bergerak (perkawatan magun) dengan atau tanpa konektor.
SNI 04.6629.4-2006
ex ex ex ex ex ex ex ex ex ex
8544.11.10.00 8544.11.20.00 8544.11.90.10 8544.11.90.20 8544.11.90.90 8544.42.91.00 8544.42.92.00 8544.49.22.00 8544.49.23.00 8544.49.41.00
URAIAN PERMENPERIN 84 SNI KABEL WAJIB (2014) RUANG LINGKUP PEMBERLAKUAN “SNI WAJIB KABEL” ex 8544.11.10.00 Kabel berinti tunggal atau multi inti berbentuk padat atau 3
4
dipilin atau fleksibel berpenghantar tembaga, aluminium, atau paduan aluminium baik polos, dianil atau dilapis, berisolasi PVC (Polyvinyl Chloride), PE (Poly Ethylene), XLPE (Cross Link Poly Ethylene), EPR (Ethylene Propylene Rubber), HEPR (High Module Ethylene Propylene Rubber), bebas halogen dan elastomer, untuk voltase pengenal 1 kV sampai dengan 3 kV
Kabel berinti tunggal atau multi inti berbentuk padat atau dipilin atau fleksibel berpenghantar tembaga, aluminium, atau paduan aluminium baik polos, dianil atau dilapis, berisolasi PVC (Polyvinyl Chloride), PE (Poly Ethylene), XLPE (Cross Link Poly Ethylene), EPR (Ethylene Propylene Rubber), HEPR (High Module Ethylene Propylene Rubber), bebas halogen dan elastomer, untuk voltase pengenal 1 kV sampai dengan 3 kV
SNI 04.6629.5-2006
SNI IEC 60502.1-2009
ex ex ex ex ex ex ex ex ex
8544.11.20.00 8544.11.90.10 8544.11.90.20 8544.11.90.90 8544.42.91.00 8544.42.92.00 8544.49.22.00 8544.49.23.00 8544.49.41.00
ex ex ex ex ex ex ex ex ex ex ex ex
8544.11.10.00 8544.11.20.00 8544.11.90.10 8544.11.90.20 8544.11.90.90 8544.19.00.10 8544.19.00.90 8544.42.91.00 8544.42.92.00 8544.49.41.00 8544.60.11.00 8544.60.19.00
URAIAN PERMENPERIN 84 SNI KABEL WAJIB (2014) RUANG LINGKUP PEMBERLAKUAN “SNI WAJIB KABEL” ex 8544.11.10.00 Kabel berinti tunggal atau multi inti berbentuk padat atau 5
dipilin, berpenghantar tembaga polos dan dianil berlapis logam serta aluminium atau paduan aluminium polos dan berisolasi terekstrusi , berisolasi PVC (Polyvinyl Chloride), PE (Poly Ethylene), XLPE (Cross Link Poly Ethylene), EPR (Ethylene Propylene Rubber), HEPR (High
SNI IEC 60502.2-2009
ex ex ex ex ex ex ex ex
8544.11.20.00 8544.11.90.10 8544.11.90.20 8544.11.90.90 8544.19.00.10 8544.19.00.90 8544.60.11.00 8544.60.19.00
NO SNI, TYPE, BAHAN DAN PENAMAAN PADA KABEL DIANTARA KELOMPOK KABEL BERDASARKAN JENIS & UKURAN PADA SNI KABEL WAJIB NO
GROUP & JENIS
No.
1
SNI 04.6629.3-2006 (450/750 V)
1 2
CU/PVC CU/PVC-f
NYA NYAF
4 3
2
SNI 04.6629.4-2006 (450/750 V)
3
SNI 04.6629.5-2006 (450/750 V)
4
SNI IEC 60502.1-2009 0,6/3 KV
3 4 5 6 7 8 9 10 11 12 13 14 15 16
CU/PVC/PVC CU/PVC-f/PVC CU/PVC-f CU/PVC/PVC CU/PVC/SFA/PVC CU/XLPE/PVC CU/XLPE/SFA/PVC AL/XLPE/PVC AL/XLPE/SFA/PVC CU/XLPE/DSTA/PVC CU/PVC/CWS/PVC CU/XLPE/CTS/PVC CU/XLPE/CWS/AWA/PVC AL/XLPE/CWS/PVC
NYM NYMHY NYZ NYY NYFGbY N2XY N2XFGbY NA2XY NA2XFGbY N2XBY NYCY N2XSY N2XSRaY NA2XSY
8 4 1 22 18 12 18 12 9 12 6 3 3 3
5
SNI IEC 60502.2-2009 3-30 KV
17 18
CU/XLPE/CWS/DSTA/PVC CU/XLPE/CWS/SFA/PVC
NA2XSEYBY N2XSEFGbY
2 3
19
AL/XLPE/CWS/DSTA/PVC
NA2XSEYBY
3
20
AL/XLPE/CWS/SFA/PVC
NA2XSEFGbY
3
9
35
PENAMAAN DALAM SNI
NAMA LAIN
JUMLAH UKURAN
184
CONTOH JENIS KABEL SNI WAJIB KELOMPOK SNI KABEL WAJIB BERDASARKAN JENIS & UKURAN NO
1
2
GROUP SNI
NO
PENAMAAN SNI
NAMA LAIN
1 CU/PVC
NYA
2 CU/PVC-f
NYAF
1 CU/PVC/PVC
NYM
GAMBAR
SNI 6629.3
SNI 6629.4
1 CU/PVC/PVC-f 3
NYMHY
SNI 6629.5 2 CU/PVC-f
NYZ
CONTOH JENIS KABEL SNI WAJIB KELOMPOK SNI KABEL WAJIB BERDASARKAN JENIS DAN UKURAN NO
GROUP SNI
SNI IEC 60502.1-2009 TEGANGAN RENDAH 1 -- 3 KV
PENAMAAN SNI
GAMBAR
CU/PVC/PVC
NYY
CU/PVC/SFA/PVC
NYFGBY
CU/XLPE/PVC
N2XY
CU/XLPE/SFA/PVC
N2XSFGBY
AL/XLPE/PVC
NA2XY
AL/XLPE/SFA/PVC
NA2XSFGBY
CU/XLPE/DSTA/PVC
N2XBY
CU/PVC/CWS/PVC
NYSY
Serta jenis2 kabel lainnya
CONTOH JENIS KABEL SNI WAJIB KELOMPOK SNI KABEL WAJIB BERDASARKAN JENIS & UKURAN
NO
GROUP SNI
NO
PENAMAAN SNI
1 CU/XLPE/CWS/PVC
2 CU/XLPE/CWS/AWA/PVC SNI IEC 60502.23 AL/XLPE/CWS/PVC 2009 TEGANGAN MENENGAH
N2XSRaY NA2XSY N2XSEYBY
5 CU/XLPE/CWS/SFA/PVC
N2XSEFGbY
6 AL/XLPE/CWS/DSTA/PVC
NA2XSEBY
7 AL/XLPE/CWS/SFA/PVC
3 -- 33 KV
N2XSY
4 CU/XLPE/CWS/DSTA/PVC
PERSAMAAN
Serta jenis2 kabel lainnya
NA2XSEFGbY
GAMBAR
TAHAPAN PEMERIKSAAN
SNI KABEL
PEMERIKSAAN & PENGAWASAN SNI OLEH KEMENPERIN :
* Pemeriksaan Awal untuk SPPT - SNI Baru * Pengawasan Penerapan SNI di Area Pabrik * Pengawasan Penerapan SNI di Luar Pabrik
PENGUJIAN VISUAL & DIMENSI DI PASAR : * Pengujian SNI No. * Pengujian SNI IEC
Warna Inti, mengacu pada 04-6629.1:2006 & 04-6629.1:2011 Diameter Konduktor, mengacu pada No. 60228:2009
PENCANTUMAN NAMA TANDA SNI DI KABEL Tata Cara Pencantuman TANDA SNI di Kabel :
Setiap produk kabel sesuai “SNI Wajib Kabel” harus mencantumkan tanda SNI yang tidak mudah hilang dengan Printing atau Embossed dengan ketentuan Sekurang-
kurangnya
Tanda dan No SNI ; Merek Dagang ; Jenis & Ukuran ; Tegangan Pengenal ; (Jenis produk ekuivalen) atau seperti contoh berikut : SNI IEC 60502.1:2009 “MERK” Cu/PVC/PVC 4x6 mm2 0,6/1 kV (NYY) SNI 04.6629.3 : 2006 “MERK” Cu/PVC 6 mm2 450/750 V (NYA)
LABEL SNI
PADA KEMASAN KABEL CONTOH PENULISAN LABEL SNI KABEL
0 4 NRP
-
6 6 2 9
-
4 .
.
.
1 0 3 - 0 2 7 - 0 9 0 1 7 0
Penjelasan: 103 = Nomor Registrasi di Direktorat Standardisasi Kemendag untuk LSPro 027 = Nomor Identitas daerah produsen/kode daerah........ 090170 = Tahun pendaftaran NRP dan NO Urut Pendaftaran NRP yang diberikan kepada Produsen Ditambah lagi dengan : Type dan Ukuran serta Tegangan Pengenal Kabel, Merk, Nama dan Alamat Perusahaan, Produksi / Made in Indonesia, panjang dan satuannya, serta standar label lainnya.
PARAMETER PENGUKURAN KABEL UKURAN INTI, DIAMETER & TAHANAN CuMAX UKURAN DIAMETER KONDUKTOR DIA. MIN DIA. NILAI R MAX INTI
NOMINAL
PRAKTEK
SNI IEC 60228 TAHANAN COND
1,5 mm2
1,38 mm
1,34 mm
1,5 mm
12,1 Ohm/Km
2,5 mm2
1,78 mm
1,72 mm
1,9 mm
7,41 Ohm/Km
4 mm2
2,25 mm
2,19 mm
2,4 mm
4,61 Ohm/Km
6 mm2
2,76 mm
2,67 mm
2,9 mm
3,08 Ohm/Km
10 mm2
3,57 mm
3,47 mm
3,7 mm
1,83 Ohm/Km
Data Referensi : Buku SNI IEC 60228-2009, halaman 5 & 13
PENGAWASAN SNI KABEL DI PASAR PENGAWASAN DI PASAR (KEMENDAG) o
Barang yang SNI-nya diberlakukan secara wajib oleh instansi teknis terkait dan telah dinotifikasi ke WTO.
o
Melalui mekanisme penerbitan dokumen : NPB untuk Barang Impor & NRP untuk Barang Lokal DN
o
Peraturan Pencantuman Label di Produk & Kemasan
o
Pemeriksaan / Inspeksi Pasar
o
Undang-undang Perlindungan Konsumen (Denda Max Rp. 2,5 Milyar atau Kurungan Penjara Max 6 Bulan)
SANKSI PELANGGARAN SNI WAJIB BEBERAPA SANKSI PELANGGARAN SNI WAJIB o
UU PERLINDUNGAN KONSUMEN (Denda & Kurungan)
o
UU PERINDUSTRIAN No.3/2014 (Denda & Kurungan)
o
UU STANDARISASI & PENILAIAN KESESUAIAN
No.20/2014 (Denda & Kurungan) o
UU Kepabeanan (Denda / Re Expor / Hanguskan)
o
Pencabutan / Pembatalan Sertifikat SPPT SNI
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN K KESELAMATAN KELISTRIKAN CONTOH LABEL YANG SALAH (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSI PASAR SNI KABEL WAJIB KESELAMATAN KELISTRIKAN K CONTOH LABEL KESELAMATAN KELISTRIKAN YANG SALAH (2015) HOTEL KAISAR JAKARTA, 2010 EMERALD GARDEN INT’L HOTEL - MEDAN,11 14MEI APRIL2010
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN K KESELAMATAN KELISTRIKAN CONTOH LABEL YANG SALAH (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN K KESELAMATAN KELISTRIKAN CONTOH LABEL YANG SALAH (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN K KESELAMATAN KELISTRIKAN CONTOH LABEL YANG BENAR (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN K KESELAMATAN KELISTRIKAN CONTOH LABEL YANG BENAR (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
K
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN KESELAMATAN KELISTRIKAN CONTOH PRINTING SALAH (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
K
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN KESELAMATAN KELISTRIKAN CONTOH PRINTING SALAH (2015) HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
K
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN KESELAMATAN KELISTRIKAN CONTOH PRINTING (2015) HOTEL INT’L KAISAR -SALAH JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
K
SEMINAR SOSIALISASI SEMINAR SOSIALISASI INSPEKSIKESELAMATAN PASAR SNI KABEL WAJIB KELISTRIKAN KESELAMATAN KELISTRIKAN CONTOH PRINTING (2015) HOTEL INT’L KAISAR -BENAR JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
BEBERAPA MASALAH / INDIKASI PELANGGARAN SNI KABEL WAJIB BEBERAPA INDIKASI PELANGGARAN : 1. Label / Packing / Kemasan Kabel 2. Printing Kabel 3. Warna Isolasi Inti Kabel 4. Bahan & Mutu Isolasi Inti Kabel 5. Diameter Inti Kabel / Konduktor 6. Bahan Inti Kabel / Konduktor 7. Tahanan Inti Kabel / Konduktor 8. Tahanan Insulation Kabel 9. Masih ada BUMN yang belum pakai SNI Kabel 10. Masih ada Project Asing yang tidak pakai SNI
K
PENYEBAB SEMINAR SOSIALISASI SEMINARKEBAKARAN SOSIALISASI KESELAMATAN KELISTRIKAN KESELAMATAN KELISTRIKAN KARENA LISTRIK
HOTEL INT’L KAISAR - JAKARTA, 2010 EMERALD GARDEN HOTEL - MEDAN,11 14MEI APRIL2010
PENYEBAB UTAMA KEBAKARAN KARENA LISTRIK
o PEMAKAIAN BARANG / MATERIAL YANG JELEK (Kabel, MCB, Saklar, Stop Kontak dll) o PEMASANGAN & INSTALASI JARINGAN YANG TIDAK BENAR o KEBIASAAN YANG SALAH o NIAT YANG TIDAK BENAR
K
CARA MEMILIH KABEL SEMINAR SOSIALISASI SEMINAR SOSIALISASI KESELAMATAN KELISTRIKAN KESELAMATAN KELISTRIKAN YANG BAIK DAN BENAR HOTEL KAISAR - JAKARTA, 11 MEI 2010
EMERALD GARDEN INT’L HOTEL - MEDAN, 14 APRIL2010
BEBERAPA CARA PEMILIHAN KABEL YANG BAIK o
LABEL PRODUK YANG BENAR
o
PRINTING / PENAMAAN DI KABEL YANG BENAR
o
KONDUKTOR TEMBAGA YANG BAIK & BENAR
o
BAHAN ISOLASI YANG BAIK & BENAR
o
TAHANAN KONDUKTOR YANG BAIK & BENAR
o
NIAT YANG BAIK & BENAR
SOSIALISASI PUBLIK SNI KABEL WAJIB
SOSIALISASI PUBLIK SNI KABEL WAJIB