EMP-168

EMP - 168

Biochemical Analyzer Technical Specifications Optics

340, 405, 505, 546, 578, 620, 670nm, one more optional filter

Light source

Halogen 6V/10W

Resolution

0.001Abs

Photometric range

0.000-3.000Abs

Stability of absorbency

Changes<0.005 Abs per hour

Repeatability

CV≤0.5%

Carry over

≤1%

Linearity

R≥0.999

Flow cell

32ul with peltier temperature control (25℃, 30℃, 37℃)

Memory

200 test programs and over 100,000 test results

Display

7″TFT LCD

Printer

Built - in thermal printer

Data communication

RS-232, SD card and USB

CPU

High speed embedded processor

Power supply

AC 100-240V, 50/60Hz

Weight

7 Kg

Dimension(mm)

420(L)x310(W)x152(H)

www.china-emperor.com

Options

Biochemical Analyzer

Windows based user friendly interface 7″TFT adjustable LCD Air purge between samples to avoid carry over DISTRIBUTOR , Add:2/F, Building 7, Tian an Nanyou Industrial Area, Nanshan District, Shenzhen 518054, China Tel:+86-755-26073285 26415597

Fax:+86-755-26415597 26419886

E-mail:[email protected]

Http://www.china-emperor.com

Support RS-232, USB, Ethernet and SD card

We reserve the right to make modifications without prior notification EN.168.200912

PR OD UC T SE RVIC E

ISO 13485:2003

EMP - 168 Biochemical Analyzer

Friendly Interface Windows CE.NET operation system Angle adjustable LCD and touch screen (optional) Built-in printer and external printer (optional) USB mouse, virtual screen keyboard and built-in membrane keyboard Connect PC via RS-232 to transfer and print the data

Optical System Halogen-tungsten lamp Automatic by 8 positions filter-wheel 7 filters(340nm-670nm) plus 1 free position

Measure System End point, kinetics, two-point and absorbance Immunity nephelometery measure method Reagent blank and sample blank Multi-standards (linear or non-linear) Memory for reagent blank

Flow Cell/Cuvette

Powerful Software Power on self-check and malfunction alarm Lamp automatic protection, user-define setting time

32ul quartz flow cell I built-in bottom position localizer

Real time absorbance curve and temperature display

Two-holder for cuvette/flow cell

Open system for reagent

Peltier temperature control

Support on-line printing Multiform reports by project, patient or history data Support user-define template test