Gen Motor

Datasheet BF8M1015 (1500 min-1 / 50 Hz)

Engine Type ‚

BF8M1015C



Speed Net frequency





BF8M1015CP [min-1]

1500

[Hz]

50

Power standard



‚ 1500

1500

50

50



1500

1500

50

50

COP



1500

1500

1500

50

50

50

PRP

Power level

G1

G3

Exhaust emission standard

--

--

G1

G2

LTP G3

TAL 2000

G1

G2

G3

--

--

--

General Aspiration

turbo, CAC

No of cylinders

8

Configuration

8

8

V

Injection system Displacement

turbo, CAC

8

turbo, CAC 8

8

V

BOSCH inline pump

8

8

V

BOSCH inline pump

BOSCH inline pump

[l]

15.9

15.9

15.9

15.9

15.9

15.9

15.9

15.9

Bore

[mm]

132

132

132

132

132

132

132

132

Stroke

[mm]

145

145

145

145

145

145

145

145

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

Compression ratio Mean effective pressure

[bar]

16.2

19.4

18.6

19.7

21.9

20.5

22.7

24.0

Piston speed

[m/s]

7.26

7.26

7.26

7.26

7.26

7.26

7.26

7.26

Rotation (looking at flywheel)

counter clock wise

No of teeth on flywheel ring gear

counter clock wise

counter clock wise

167

167

167

167

167

167

167

167

! 0

! 0

! 0

! 0

! 0

! 0

! 0

! 0

Governor performance Speed droop (static) mech. gov.

[%]

Speed droop (static) electr. gov. (EMR/GAC)

[%]

Governing standards to ISO 8528 Parts 1 and 5

G2

G2

G2

Moment of inertia Engine without flywheel

[kg m2]

0.98

0.98

0.98

0.98

0.98

0.98

0.98

0.98

Flywheel (standard genset spec.)

[kg m2]

2.26

2.26

2.26

2.26

2.26

2.26

2.26

2.26

Max. step load acceptance, 1st step

[%]

!

70

65

60

[dB(A)]

! 118.5

!

119.5

119.5

119.5

! 119.5

! 119.5

! 119.5

Sound press. (1m average, full load), incl. cool. syst. [dB(A)]

104

!

105

105

105

105

105

105

Sound power at full load, incl. cooling system5 Weight Engine dry, w/o cooling system

[kg]

1060

1060

1060

1060

1060

1060

1060

1060

Engine with cooling system

[kg]

1240

1265

1265

1265

1300

1265

1270

1300

Lubrication system Oil specification

see operation manual

Oil consumption (as % of fuel consumption)

see operation manual

see operation manual

0.3

0.3

0.3

0.3

0.3

0.3

0.3

0.3

[l]

45

45

45

45

45

45

45

45

Min. oil pressure (warning)

[bar]

3

3

3

3

3

3

3

3

Min. oil pressure (shut down)

[bar]

2.7

2.7

2.7

2.7

2.7

2.7

2.7

2.7

Max. permissible oil temperature (oil pan)

[°C]

130

130

130

130

130

130

130

130

Gross output1

[kW]

333.0

399.0

380.0

402.0

448.0

418.0

459.0

490.0

Fan reduction

[kW]

10.7

14.1

10.7

10.7

14.1

10.7

9.3

14.1

Net flywheel1

[kW]

322.3

384.9

369.3

391.3

433.9

407.3

449.7

475.9

Electrical output2

[kVA]

375

447

429

460

510

479

528

559

25% load3

[l/h]

22.3

26.7

25.0

26.2

30.0

26.7

29.1

31.5

50% load3

[l/h]

40.6

49.9

46.7

48.8

56.4

50.5

55.5

61.8

75% load3

[l/h]

60.4

74.5

69.7

73.3

84.9

75.8

84.0

93.2

100% load3

[l/h]

80.9

102.1

94.3

99.6

118.7

103.5

117.5

131.3

25% load

[g/kWh]

224

224

220

218

224

214

212

215

50% load

[g/kWh]

204

209

205

203

210

202

202

211

75% load

[g/kWh]

202

208

204

203

211

202

204

212

100% load

[g/kWh]

203

214

207

207

221

207

214

224

2

2

2

2

2

2

2

2

Oil capacity (sump)

Output

Fuel System Fuel consumption

Max. suction head of fuel feed pump

© 2004

[m]

1

Gen Motor

Datasheet BF8M1015 (1500 min-1 / 50 Hz)

Engine Type ‚

BF8M1015C



Speed Net frequency





BF8M1015CP [min-1]

1500

[Hz]

50

Power standard



‚ 1500

1500

50

50



1500

1500

50

50

COP



1500

1500

1500

50

50

50

PRP

Power level

G1

G3

Exhaust emission standard

--

--

G1

G2

LTP G3

TAL 2000

G1

G2

G3

--

--

--

Cooling System General engine cooling data Max. perm. coolant outlet temperature

[°C]

103

103

103

103

103

103

103

103

Max. perm. flow resistance (cool. syst. and piping)

[bar]

0.35

0.35

0.35

0.35

0.35

0.35

0.35

0.35

Max. temperature of coolant (warning)

[°C]

105

105

105

105

105

105

105

105

Max. temperature of coolant (shutdown)

[°C]

108

108

108

108

108

108

108

108

Temperature at which thermostat starts to open

[°C]

83

83

83

83

83

83

83

83

Temperature at which thermostat is fully open

[°C]

95

95

95

95

95

95

95

95

[m3/h]

20.8

20.8

20.8

20.8

20.8

20.8

20.8

20.8

Min. pressure before coolant pump

[bar]

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

Temperature at CAC outlet at standard conditions

[°C]

50

50

50

50

50

50

50

50

Coolant capacity (engine)

[l]

21

21

21

21

21

21

21

21

Coolant capacity (incl. cooling unit)

[l]

99

102

102

102

116

102

102

116

Delivery of coolant pump

DEUTZ cooling system

Air to boil (max. permissible cool. air temp. at fan)

[°C]

59

54

55

52

49

52

54

49

Fan power consumption4

[kW]

10.7

14.1

10.7

10.7

14.1

10.7

9.3

14.1

[m3/h]

24120

33120

24120

24120

33120

24120

32940

33120

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5

Cooling air flow Air pressure loss Heat Balance Heat dissipation (engine radiator)6

[kW]

184

214

202

211

237

202

223

237

Heat dissipation (CAC)6

[kW]

73

101

94

103

125

94

109

124

Heat dissipation (convection)

[kW]

26

32

30.5

32.5

36

!

37

40

Inlet / Exhaust Data Max. intake depression (Switch setting)

[mbar]

50

50

50

50

50

50

50

50

Combustion air volume

[m3/h]

1524

1709

1663

2092

1848

1953

1909

2002

Max. exhaust back pressure

[mbar]

50

50

50

50

50

50

50

50

[ºC]

460

535

485

510

560

515

540

600

Exhaust gas flow (at above temp)

[m3/h]

3934

4870

4395

4765

5377

5375

5410

6012

Exhaust flange / pipe diameter

[mm]

100

118

100

100

118

100

100

118

Max. exhaust gas temperature

Electrical System Voltage

[V]

24

24

24

24

24

24

24

24

Starter

[kW]

5.4

5.4

5.4

5.4

5.4

5.4

5.4

5.4

[A]

55

55

55

55

55

55

55

55

Alternator output Batteries (minimum capacity, cold start limit -5°C)

[Ah]

2 x 143

2 x 143

! Data under examination 1Ratings in accordance with ISO 3046. 2Ratings in accordance with ISO 8528, based on alternator efficiency of 93% to 94%. 3At calorific value 42700 kJ/kg + 5 %, density 0.835 kg/dm3, temperature 280 K. 4Technical data and max. permissible torque for fan drive see data sheet. 5Sound power values measured in accordance with ISO 6798. 6The heat quantities are valid for the dimensioning of the cooling system. They are given for the engine with the highest fuel consumption. For further information see ELTAB / Pocket book. For further application guidance see DEUTZ Installation Manual. All data are provided for informational purposes only and are subject to amendment.

© 2004

2

2 x 143

Related Documents