CONVENTION CENTRE Literature Study SUBMITTED TO – AR.VINOD PATIL
BY – ANIRUDDH BABBAR ANIRUDH SHARMA ANKIT GUPTA DIPANSHU GUPTA MOHD.SHAHAAB
CONTENT •
PARKING
•
RESTAURANTS
•
OFFICES
•
RECPTION
• EXIBHITION HALL
•
WAITING AREA
• LIBRARY
•
BANQUET/ CATERING
• O.A.T
•
FACILITIES
•
PUBLIC CONVINENCES
•
BIBLOGRAPHY
• INTRODUCTION • REQUIRMENTS • CONVENTION HALL
• AUDITORIUM
INTRODUCTION
INTRODUCTION WHAT IS CONVENTION CENTRE?
• A CONVENTION CENTER IS A LARGE BUILDING THAT IS DESIGNED TO HOLD A CONVENTION, WHERE INDIVIDUALS AND GROUPS GATHER TO PROMOTE AND SHARE COMMON INTERESTS.
• CONVENTION CENTERS TYPICALLY OFFER SUFFICIENT FLOOR AREA TO ACCOMMODATE SEVERAL THOUSAND ATTENDEES. VERY LARGE VENUES, SUITABLE FOR MAJOR TRADE SHOWS, ARE SOMETIMES KNOWN AS EXHIBITION CENTERS. • CONVENTION CENTERS TYPICALLY HAVE AT LEAST ONE AUDITORIUM AND MAY ALSO CONTAIN CONCERT HALLS, LECTURE HALLS, MEETING ROOMS, AND CONFERENCE ROOMS. • MULTIPLE EVENTS CAN BE ACCOMMODATED IN CONVENTION CENTRES.
• CONVENTIONS USUALLY LAST FOR AN ENTIRE DAY OR LONGER, SOME PROVIDE FOOD AND NEED ACCESS TO KITCHENS.
REQUIRMENTS
REQUIRMENTS •
CONVENTION HALL
• STORAGE AREAS
•
MINI CONVENTION HALLS
• UTILITY ROOMS
•
EXHIBITION HALL
• MEDICAL FACILITIES
•
O.A.T
• BANQUET/ CATERING FACILITIES
•
INFORMATION BOOTH/ RECEPTION
• VIP AREAS
•
WAITING AREAS
• PUBLIC CONVENIENCES
•
PARKING
• ADMINISTRATION OFFICES
•
RESTAURANTS
• TECHNICAL FACILITIES
•
SECURITY OFFICE
• LIBRARY
•
HVAC SERVICES
• CLUB HOUSE
•
DISABLE FRIENDLY AREAS
• SOVENIR AND OTHER SHOPS
CONVENTION HALL
CONVENTION HALL • CONVENTION HALL AS THE NAME SUGGESTS SHOULD HAVE AUDIO VISUAL CONFERENCING EQUIPMENT, FACILITY FOR HIGH FIDELITY RECORDING, VIDEO PROJECTION/ VIDEO GRAPHS ETC. • KILLED MANPOWER AT VARIOUS LEVELS IS REQUIRED. • THE SEATING CAPACITY IN THE HALL MAY VARY.
DIFFERENT TYPES OF SEATING ARRANGEMENT
AUDITORIUM
AUDITORIUM • AN AUDITORIUM IS A ROOM BUILT TO ENABLE AN AUDIENCE TO HEAR AND WATCH PERFORMANCES. • THE AUDITORIUM ARE AREAS USUALLY FOR LARGE MEETINGS, PRESENTATIONS. • AUDITORIUM SPACE TYPE FACILITIES MAY INCLUDE ASSEMBLY HALLS, EXHIBIT HALLS, AUDITORIUMS, AND THEATERS.
GUANGZHOU OPERA HOUSE, CHINA
AUDITORIUM • THE TICKET COUNTER AREA SHOULD BE LOCATED IN THE LOBBY SO THAT THE PATRONS ENTER THE BUILDING TO BUY TICKETS OR TO CHECK IN FOR CONFERENCE.
AUDITORIUM •
STAGGERED SEATING SHOULD BE PROVIDED TO GIVE MAXIMUM VIEW OF STAGE.
•
150MM SHUOLD BE MAINTAINED BETWEEN A VIEWERS LINE OF SIGHT AND THE TOP OF THE PERSONS HEAD SITTING IN FRONT OF THE VIEWER.
•
SIDE AND REAR WALL FOR SOUND ABSORPTIVE
•
THE CEILING SHOULD BE DESIGNED IN SUCH A WAY IT REFLECTS THE SOUND MORE.
•
THE VOICE SHOULD BE HEARD BY EVERYONE.
•
AUDITORIUM SHOULD BE ACOUSTICALLY ISOLATED
AUDITORIUM • THE PLAN SHOULD BE CLEAR ENOUGH SO THAT DIRECTIONAL SIGNAGE IS NOT NECESSARY. • DIRECT ACCESS AND EXITS IS VER IMPORTANT TO FACILITATE EFFICIENT MOVEMENT OF PATRONS. • PROVIDING FOLDING, SELF RAISING SEATS. • SEATING CAPACITIES FOR DISABLED.
AUDITORIUM • PROVIDE A MULTIPURPOSE ROOM. • REHERSAL ROOM • PROVIDE CHANGING ROOMS. • STORAGE AREA SHOULD ALSO BE PROVIDED.
• TOILETS FOR THE PARTICIPANTS. • PROJECTION ROOM.
BACK STAGE AREA
AUDITORIUM • A MINIMUM OF FOUR WHEELCHAIR SPACES SHALL BE PROVIDED AT SPECTATOR LEVEL IN THE AUDITORIUM WITH NOT MORE THAN 800 FIXED SEATS. • EACH WHEELCHAIR SPACE SHALL HAVE UNOBSTRUCTED LINE OF VISION TO THE STAGE AREAS AT WHICH THE RELEVANT ACTIVITY TAKES PLACE, AND BE OF MINIMUM SIZE OF 800 MM X 1300 MM. • THE MINIMUM WIDTH OF THE PASSAGE LEADING TO A WHEELCHAIR SPACE FROM AN ACCESSIBLE ENTRANCE OF THE AUDITORIUM SHALL NOT BE LESS THAN 1500 MM.
SPACE FOR DISABLED PEOPLE
AUDITORIUM
EXAMPLE FOR 1000 PEOPLE AUDITORIUM
EXIBHITION HALL
EXIBHITION HALL • AN EXHIBITION, IS AN ORGANIZED PRESENTATION AND DISPLAY OF SELECTED ITEMS. • THIS ORGANIZED DISPLAY IS DONE IN EXIBHITION HALLS. • THESE HALL CAN HAVE MULTIPURPOSE USES. • THESE CAN BE USED FOR SELLING GOODS. • THESE CAN ALSO BE USED TO DISPLAY PAINTINGS.
EXIBHITION HALL
STD. MEASURMENT OF ADULT AND SIX YEAR OLD VISITOR
DIFFICULTIES ENCOUNTERED
EXIBHITION HALL • STANDARD BOOTHS MUST NOT BE HIGHER THAN 8’ AT THE BACK WALL AND 4’ ON THE SIDE. • DISPLAY FIXTURES OVER 4’ IN HEIGHT MUST BE CONFINED TO THAT AREA OF THE EXHIBIT BOOTH WHICH IS WITHIN 5' OF THE BACKLINE. • PROHIBITION OF USAGE OF SPACE BEYOND BOOTH BOUNDARIES.
EXIBHITION BOOTH
LIBRARY
LIBRARY • PUBLIC LIBRARIES CAN BE DIFFERENTIATED FROM ACADEMIC, SCHOOL, AND SPECIAL LIBRARIES BECAUSE THEY FUNCTION TO SERVE THE NEEDS OF A DIVERSE SERVICE POPULATION INCLUDING SMALL CHILDREN, STUDENTS, PROFESSIONALS, AND THE ELDERLY.
LIBRARY LAYOUT
LIBRARY
STANDARD HEIGHTS FOR LIBRARIES
STANDARD AREA BETWEEN TWO SHELVES
LIBRARY THERE ARE FIVE BROAD TYPES OF PUBLIC LIBRARY SPACE: • COLLECTION SPACE • USER SEATING SPACE • STAFF WORK SPACE
• MEETING SPACE • SPECIAL USE SPACE • NON-ASSIGNABLE SPACE
STANDARD DISTANCES BETWEEN TABLES
O.A.T
O.A.T • AN OPENAIR THEATER OR AMPHITHEAT ER IS AN OPEN-AIR VENUE USED FOR ENTERTAINMENT, PERFORMANCES, AND SPORTS. • IT CREATES AN AREA WHICH ECHOES OR AMPLIFIES SOUND, MAKING IT IDEAL FOR MUSICAL OR THEATRICAL PERFORMANCES. • SMALL-SCALE AMPHITHEATERS CAN SERVE TO HOST OUTDOOR LOCAL COMMUNITY PERFORMANCES.
EXAMPPLE OF AN O.A.T
PARKING
PARKING THE FOLLOWING ARE STANDARD SPACE REQUIREMENTS OF SOME TYPICAL VEHICLES • CAR 2.4 METRES X 4.8 METRES • LIGHT VANS 2.4 METRES X 5.5 METRES • RIGID VEHICLES 3.5 METRES X 14.0 METRES • COACHES (60 SEATS) 3.5 METRES X 14.0 METRES
STANDARD CAR DIMESNIONS
PARKING
EXAMPLE OF AN CAR PARKING
RAMP STANDARD
PARKING
MULTI-LEVEL PARKING DESIGN
MEDUIM SIZED CAR TURNING RADIUS
PARKING
PARKING LOT DESIGN TYPICAL PARKING PLAN
RESTAURANTS
RESTAURANTS
CIRCULATION STANDARDS
TYPES OF RESTAURANTS TABLES
RESTAURANTS
SEATING STANDARDS
RESTAURANTS
RESTAURANTS COUNTER STANDARDS
RESTAURANTS
STANDARD RESTAURANT SEATING
OFFICES
OFFICES
OFFICE FURNITURE SIZES
OFFICES
UTILITES ROOM STANDARDS
TYPICAL OFFICE ROOM STANDARDS
RECPTION
RECPTION
STANDARD RECPTION WORKING HEIGHTS
WAITING AREA
WAITING AREA
EXAMPLE OF AN WAITING ROOM
WAITING AREA STANDARDS
BANQUET/ CATERING FACILITIES
BANQUET/ CATERING FACILITIES
BANQUETTE SEATING STANDARDS
PUBLIC CONVENIENCES
PUBLIC CONVENIENCES • TOILETS SHOULD PROVIDE CLEAN, SAFE, ACCESSIBLE, CONVENIENT, AND HYGIENIC FACILITIES TO THE PUBLIC AT A LEVEL OF PRIVACY ADEQUATE TO PERFORM NECESSARY PERSONAL SANITARY FUNCTIONS. • TOILET ROOMS SHOULD BE VENTILATED BY NATURAL OR MECHANICAL MEANS. EXAMPLE OF A TOILET
PUBLIC CONVENIENCES
WB DESIGN STANDARDS
URINAL DESIGN STANDARDS
PUBLIC CONVENIENCES
STANDARD CUBICLE DIMESNSIONS
BIBLOGRAPHY • HTTPS://WWW.WBDG.ORG/DESIGN/PUBLIC_LIBRARY.PHP • TIMES SAVER STANDARDS
• HTTPS://WWW.ACADEMIA.EDU/5872534/DESIGN_STANDARDS_CONFERENCE_BUILDINGS_ EXHIBITION_AND_RESEARCH_BUILDINGS • HTTP://TOURISM.GOV.IN/SITES/DEFAULT/FILES/053120111252649.PDF • HTTPS://WWW.WBDG.ORG/DESIGN/AUDITORIUM.PHP • HTTPS://EN.WIKIPEDIA.ORG/WIKI/AMPHITHEATRE • HTTP://WWW.PLANNINGNI.GOV.UK/DOWNLOADS/PARKING-STANDARDS.PDF • HTTPS://ADMIN.STATE.NH.US/BPM/INTERIOR%20SPACE.PDF • HTTPS://WWW.BRISBANE.QLD.GOV.AU/SITES/DEFAULT/FILES/PUBLIC_TOILET_DESIGN_G UIDELINES_UPDATED.PDF • HTTP://WWW.WASHROOMCUBICLES.CO.UK/TOILET-CUBICLE-SIZES/