CONFINED SPACE ENTRY PLAN BEST PRACTICE FACILITY: EQUIPMENT: DIVISION: UNIT: SCOPE OF THE WORK

YRD-ARAMCO V06-D-0001 RICH AMINE FLASH DRUM Maintenance Division 2019 Turnaround Coordination Unit

ISOLATION METHOD

CSEP WILL NOT EXCEED 30 DAYS START DATE: 06-Mar-19 END DATE: ENTITY EXECUTING THE JOB FOREMAN NUMBER OF EMPLOYEES

04-Apr-19

Cleaning by Hydrojetting Locked

switch/breaker Disconnect

Blinding

Note: attach drawing showing each isolation point as well as blind list.

□ Purging □ Cleaning □ Flushing O2 CO H2S LEL□ Other: □ Steaming-out □ Natural Ventilation ATMOSPEHRIC GAS TESTING TYPES …………………………. AND FRECUENCY Mechanical Ventilation N2/CO2 □ Frequency: …………………. inerting REQUIRED TYPES OF PPE TYPES OF Self-contained breathing apparatus  Air (IN ADDITION TO Hard Hat; Clear Safety Glasses and Safety Shoes) EQUIPMENT movers  Rescue equipment Lighting REQUIRED FOR CONFINED SPACE equipment Communication equipment Personal H2S Monitor Detector  FRC  Goggles/face shield ENTRY: Fire extinguisher  Chemical suit/coverall  Gloves (Specify): Ladder required External scaffold …………………………………….……… required Internal scaffold required   Respiratory Protection (Specify): ACCESS AND Fall Protection required □ Platform ……………….…..………………………………………………………..……………..…. EGRESS modification required □ Other: □ Other:…………………………………………………..…….…. ………………………………………………………………………. Edge Protection Caution Within eye sightLine signalsRadios MEANS OF tape Hard barricade □ PROTECTION OF COMMUNICATION □Other:…………………………….. Signals were discussed SURROUNDING AREAS Warning lights WITH ENTRANTS with personnel before entry  Warning Signs□ Flagman PREVENTION OF  Posting a Sign(Do Not Enter) Closing the entry point Standby manSealing the entry point by UNAUTHORIZED warning tape□ Other ………………………………………………………………….. ENTRY ELIMINATING ATMOSPHERIC HAZARDS BY:

Saudi Aramco: Company General Use

LPD – Confined Space Entry Plan CSEP - Best Practices – 2017 – Format

CONFINED SPACE ENTRY PLAN BEST PRACTICE EMERGENCY RESPONSE AND RESCUE

Local

FrPD has been formally notified about this activityWorkers shall wear harness and Life-line at all-time Rescue equipment must be in place before work starts  Personnel trained for confined space rescue are available on site Portable Air Horn

DRAWING

`

The drawing of the Confined Space must showALLIsolation, Entry and Ventilation points

Name

Position

Badge #

Prepared by Reviewed by Compliance Group Approved by Area Foreman Acknowledged by Local FrPD Accepted by Maint. T&I Group

Saudi Aramco: Company General Use

LPD – Confined Space Entry Plan CSEP - Best Practices – 2017 – Format

Signature

Date 

Additional documents required before initiating CSE activities: CSE Work Permit Gas Testing Log Sheet CS Entry Log Sheet Job Safety Analysis

CONFINED SPACE ENTRY PLAN BEST PRACTICE Notes: 1. CSEP WILL NOT EXCEED 30 DAYS. If additional time is needed, a new CSEP will have to be prepared and approved. 2. Copy of both sides of thisApproved CSEP must be posted at the entrance of the Confined Space in clear plastic envelopes. 3. Initial confined space entry into pits, sumps, vessels, tanks, drums, or other process equipment that may have previously contained flammable, combustible, or toxic materials will require additional approvals by proponent management prior to work commencing.