Central Control Room
Location • Central control station room is located on the Ground floor of the mall with a door leading into the parking lot. • The room is accessible directly from the basement. • The central control station room is a restricted area. • Unauthorised entry is prohibited • Entry only by showing of access card
What is Central Control Room(CCR)? • Central Control Room(CCR) functions as a ‘Building Management System’ (BMS) • It controls and monitors all utilities and services present in the mall. • It is predominantly handled by the IT department of Inorbit Mall.
Building Management System • The Building Management system consists of the following services :2.Closed Circuit Television (CCTV) 3. Public Access System (PAS) 4. Access Control Systems (ACS) 5. Fire Alarm System (FAS)
Closed Circuit Television (CCTV) • The monitoring Cameras are present at 2.All entrances and exits 3.Elevators. 4.Elevator lobbies. 5. Corridors. 6. Exit Stairways. 7. Food court
Closed Circuit Television (CCTV)
Public Address System • All voice evacuation and public address systems shall operate from the Information Desk 1 (ID1) situated near the CCR on the Ground floor. • Manual control of evacuation tone signals, alert tone signals, and voice evacuation shall be provided on a selective and all-call basis.
Public Address System • Alert tones and voice instructions shall be provided to the Amplifiers in the following areas: • Elevators. • Elevator lobbies. • Corridors. • Exit Stairways. • Individual shops • Areas of rescue assistance
Access Control System (ACS) • The Access Control Systems monitors the movement of people in the restricted areas of the Mall • This includes the Mall Office , Meter Room , Central Control Room , Power Room • These areas can only be accessed by authorized personnel with the help of access cards. • The entry and exit is recorded by this
Fire Alarm System (FAS) • The Control Room consists of the Fire alarm Panel • Alarm, supervisory and trouble signals shall be annunciated in the central control station by means of an audible and visual indicator. • Inorbit Mall follows the Addressed System of Fire detection • In this system the exact location of the smoke can be detected • Here, the Fire Alarm Panel is connected to a electronic flow chart which indicates the no. & position of the smoke detector. • Fire department communication system shall be provided for fire department use. • Fire detection System No. of Smoke detectors: 192 nos. Fire Extinguishers ABC Type: 112 nos.
Fire Alarm System (FAS) • For the purpose of detection, zoning shall be in accordance with the following: Each floor of a building shall be considered as a separate zone. Each floor of a building is divided into two separate zones Identification of the type of alarm, initiation devices such as manual , automatic, sprinkler water flow, etc. shall be separately indicated on electrically supervised initiating circuits to the main fire alarm control unit. Detection panels shall be graphic to clearly indicate the layout of the building.
Other Components Building floor plans shall be permanently mounted on an interior wall within the central control station. Plans shall include the following: • Stairways. • Areas of rescue assistance. • Shafts. • Corridors. • Elevators. • Emergency generator and fuel locations. • Fire pump. • Smoke control supply and exhaust ducts. • Mechanical rooms, gas, water, electrical, fire