Enea OD BT MANUALE DEL TECNICO ENGINEER'S MANUAL MANUEL DU TECHNICIEN TECHNIKERHANDBUCH MANUAL DEL TÉCNICO MANUAL DO TÉCNICO
(rev. 1806)
Descrizione - Description - Description - Beschreibung Descripcíon - Descrição
Enea On Demand Bluetooth
1
2
3
4 10
15
7
16
12
11
13 14 19
Kg Pounds
9,5 21
IT
LEGENDA
1 Coperchio tramoggia 2 Tramoggia caffè in grani 3 Serranda tramoggia 4 Vite regolazione macine 7 Pressino 10 Display 11 Interruttore generale / Lampada spia ON 12 Forcella supporto portafiltro 13 Vassoio raccolta macinato 14 Targa dati 15 Pulsantiera 16 Scivolo caffè macinato 19 Morsetto equipotenziale
DE
LEGENDE
1 Abdeckung Trichter 2 Trichter zur Kaffeebohneneinfüllung 3 Trichterverriegelung 4 Schraube zur Mahlwerkeinstellung 7 Andrücker 10 Display 11 Hauptschalter / Kontrolleuchte ‘Gerät eingeschaltet’ 12 Filterhaltergabel 13 Tablett zur Sammlung des gemahlenen Kaffees 14 Typenschild 15 Druckknopftafeln 16 Kaffeerutsche 19 Klemme equipotentialer Anschluß
EN
LEGEND
1 Receptacle lid 2 Coffee beans receptacle 3 Receptacle door 4 Machine adjustment screw 7 Coffee tamper 10 Display 11 On-off switch / ON indicator light 12 Filter basket bracket 13 Ground coffee collection tray 14 Data label 15 Pushbutton Panel 16 Ground coffee chute 19 Unipotential terminal
ES
LEYENDA
1 Tapadera tolva 2 Tolva café en granos 3 Cierre tolva 4 Perno regulación molinillo 7 Prensa 10 Display 11 Interruptor general / Indicador luminoso ON 12 Horquilla soporte portafiltro 13 Bandeja recogida café molido 14 Tarjeta datos 15 Botoneras 16 Rampa café molido 19 Borne equipotencial
FR
LEGENDE
1 Couvercle trémie 2 Trémie café en grains 3 Fermeture trémie 4 Vis de réglage de moulage 7 Pressoir 10 Ecran 11 Interrupteur général / Lampe témoin ON 12 Fourche support porte-filtre 13 Plateau de recueil du café moulu 14 Plaquette d’informations 15 Clavier 16 Rampe de café moulu 19 Câble équipotentiel
LEGENDA PT 1 Tampa tremonha 2 Tremonha café em grão 3 Grade tremonha 4 Parafuso regulação das mós 7 Pisa-café 10 Display 11 Interruptor geral / Lâmpada pilôto ON 12 Forquilha suporte porta-filtro 13 Tabuleiro recolha café moído 14 Placa dados 15 Quadro de botões 16 Escorregão do café moído 19 Borne equipotencial
Index Page
English
Index
1
Technical Programming Menu
2
Technical Menu Table
3
Grinder adjustment
4
Ground coffee dose adjustment
5
Double dose Single dose “Zero” grinders Automatic dose correction Maintenance Grinder/dispenser no. in Bluetooth mode Reset maintenance
5 6 7 9 9 9 10
Single dose counter 10 Double dose counter 10 Manual dispensing counter 11 Total units dispensed display 11 Bluetooth module version display 11 Load standard data 12 (BDS) function 12 BDS (Barista Driving System) 13 Diagnostics messages 14 Wiring diagram 15
1 EN
Technical Programming Menu
To access programming, press the
,
,
keys in rapid succession, holding the last one for 5 seconds.
English
The menu is as follows:
MENU NO. (P1, P2, etc.) technical key icon Displayed values
LED flashing at 2Hz
The
(technical key) appears on the display.
The MENU can be changed with the By pressing the
and
keys
key (single cup), ACTIVE edit is activated (LED stops flashing and edit value starts flashing)
The value can be edited with the Pressing the Pressing the
and
keys (the value does not flash while it is being edited)
key (single cup) allows you to exit without saving (Return to MENU) key (double cup) allows you to save and exit (Return to MENU)
To exit the technical MENU, press and hold the key (double cup) for 5 seconds (the LED will stop flashing and you will be taken to the normal work screen) Note: If 20 seconds pass without pressing a key when not working on the main screen, the programming screen closes automatically without saving, returning to normal functioning.
2 EN
Technical Menu Table MENU
Function
Range
Step
Default
English
P1
Edit key 1 cup dose
1 ÷ 15 s.
0.1 s
4s
P2
Edit key 2 cups dose
1 ÷ 15 s.
0.1 s
8s
P3
Zero Grinders
no ÷ Y
P4
Dose Correction
P5
Notes
no
Y = Zero Grinders 0 = disabled
0 ÷ 10 %
0.1 %
3.5 %
Edit Maintenance Limit
10000 ÷ 99900
100
50000
P6
Grinder/dispenser no.
0÷9
0
For Bluetooth function
P7
Reset maintenance
no ÷ Y
no
Shows maintenance limit value
P8
View/Reset 1 cup key counter
-
0
P9
View/Reset 2 cups key counter
-
0
P10
View/Reset Manual Dispensing Counter
-
0
P11
View Total Dispensing Counter
-
0
P12
Bluetooth module version display
-
4.0.0
P13
Load standard data
no ÷ Y
P14
BDS Function
no ÷ Y
Y = load data 0
Y = function active
function inactive function active
3 EN
Grinder adjustment Automatic dose adaptation system. With every grinder adjustment, the grinding time of the coffee doses is automatically adapted based on the preset grind settings. COARSE
Adjusting the grinders to obtain a different grinding level is carried out using the screw (4) and variations appear on the display according to the following logic:
4
English
• •
FINE
fine grinding › grind bar reduced, low reference value; course grinding › grind bar reduced, high reference value;
If the coffee dispensing takes a very long time, this means that the coffee used is too finely ground. In this case, it is necessary to turn the ring nut (4) anti-clockwise in order to obtain a coarser grinding level (number indications increasing: 2 - 3 - 4 - ....).
fine grinding grinding bar reference value
If the coffee dispensing is very quick, this means that the coffee used is too coarsely ground. In this case, it is necessary to turn the ring nut (4) clockwise in order to obtain a finer grinding level (number indications decreasing: 4 - 3 - 2 - ....).
grinding times course grinding grinding bar reference value grinding times
NOTE: when the “Dose Correction” function is NOT enabled. the grinding time of the coffee doses remains unchanged with each grinder adjustment. dose correction active
dose correction inactive
grinding bar
grinding bar reference value
reference value
grinding times
grinding times
grinding bar
grinding bar
reference value
reference value grinding times
grinding times
4 EN
Ground coffee dose adjustment single dose To edit these dose adjustment parameters (P1): 2
1
English Press the
key (single dose);
edit the single dose time using the and keys. (in the example, it has increased by 0.5 seconds); 4
3
at the end of the operation, confirm your choices by pressing the key (double dose);
5 EN
or exit, leaving the previous choices, by pressing the key (single dose).
double dose To edit these dose adjustment parameters (P2): 1
2
English
Press the
and keys. edit the double dose time using the (in the example, it has increased by 0.4 seconds);
key (double dose);
3
4
or exit, leaving the previous choices, by pressing the key (single dose).
at the end of the operation, confirm your choices by pressing the key (double dose);
6 EN
“Zero” grinders “Zero” grinders procedure (P3): 1
2
English 3
4
5
6
7
8
7 EN
10
11
12
13
14
English
9
function inactive
A
P
Replace the grinders and reposition the supporting ring nut (A) in the grinder/dispenser, partially turning it counter-clockwise. Turn on the grinder/dispenser; the maintenance icon will appear on the display.
function active
P
30° Screw on the ring nut (A) until it just touches the grinders, and then turn it clockwise approximately 30°.
15
Turn the potentiometer (P) clockwise as far as it will go, then turn it anticlockwise for roughly 2 full turns.
Technical Mode At this point, to enable the (Zero Grinders) function, press the key (single dose); edit the (NO / Y) option using the or keys; at the end of the operation, confirm your choice by pressing the key (double dose);
reference value Note: After carrying out the “Zero Grinders” procedure to activate the “Dose Correction” function, edit the coffee dose times(P1)-(P2) in the technical menu.
Reposition the other previously removed pieces.
8 EN
Automatic dose correction Automatic dose correction (P4) With the “Dose Correction” function, a different adjustment cannot be applied to each key, but will be universal with a value between 0% and 10%. The default value will be 3.5%.
dose correction value
NOTE: inserting the value (0) will disable the “Dose Correction” function. 1. Press the
key (single dose);
English
2. edit the dose correction time using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
Maintenance Maintenance Parameter (P5): NOTE: the “Maintenance” function shows the number of cycles from a value of 10000 ÷ 99900. The default value is 50000. 1. Press the
key (single dose);
edit maintenance limit
2. edit the parameter using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
maintenance icon
Grinder/dispenser no. in Bluetooth mode Bluetooth Mode (P6): 1. Press the key (single dose); 2. edit the grinder/dispenser number in Bluetooth mode from (0 ÷ 9) using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
9 EN
Grinder/ dispenser number
Reset maintenance Reset maintenance (P7): 1. To reset “Maintenance”, press the
key (single dose);
2. edit the (NO / Y) option using the or keys; 3. at the end of the operation, confirm your choice by pressing the key (double dose); 4. or exit, leaving the previous choice, by pressing the key (single dose).
function inactive
English
NOTE: the (Reset) function displays the number of cycles that were set initially.
function active
Single dose counter (Reset) Single dose counter display (P8): 1. To reset the counters, press the
key (single dose);
2. edit the parameter using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
single dose units dispensed
Double dose counter (Reset) Double dose counter display (P9): 1. To reset the counters, press the
key (single dose);
2. edit the parameter using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
10 EN
double dose units dispensed
Manual dispensing counter (Reset) Manual dispensing counter display (P10): 1. To reset the counters, press the
key (single dose);
English
2. edit the parameter using the or keys; 3. at the end of the operation, confirm your choices by pressing the key (double dose); 4. or exit, leaving the previous choices, by pressing the key (single dose).
Manual dispensing counter
Total units dispensed display Total units dispensed display (P11): The total number of units dispensed from the grinder/ dispenser will appear on the display; (single dose); (double dose); or (manual dispensing).
total units dispensed
Bluetooth module version display *(where available) Bluetooth module version display (P12): The presence of the Bluetooth module is indicated by the relative
icon flashing on the display.
If connected to the coffee machine, the “Bluetooth” icon remains “steady” on the display.
11 EN
Bluetooth module version
Load standard data Load standard data (P13): Standard data: Reset to factory settings.
1. To enable the function, press the
key (single dose);
English
2. edit the (NO / Y) option using the or keys; 3. at the end of the operation, confirm your choice by pressing the key (double dose); 4. or exit, leaving the previous choice, by pressing the key (single dose).
function inactive
function active
BDS Function *(where available) BDS Function (P14): 1. To enable the BDS function, press the
key (single dose);
2. edit the (NO / Y) option using the or keys; 3. at the end of the operation, confirm your choice by pressing the key (double dose); 4. or exit, leaving the previous choice, by pressing the key (single dose).
BDS function inactive
BDS function active
12 EN
BDS (Barista Driving System) The BDS System is composed of a coffee machine and by one or two grinder/dispensers connected via Bluetooth. Every dispensing button on the machine can be configured based on the type of recipe and the relative grinder/dispenser. The purpose of the BDS System is to guide the user in coffee grinding and dispensing operations.
English
OPERATING LOGIC The barista positions the filter holder of the coffee machine At this point, the barista only needs to attach the filter-holder on the fork and selects the dose. The grinder/dispenser dispenses the correct quantity of and push the enabled key to dispense. ground coffee and at the same time signals to the machine which selection to enable for the preparation of the beverage.
1
2
Dispensing will remain active for 2 minutes. During this time, the grinder/dispenser used will be blocked and therefore unable to grind a second dose of coffee.
Standby phase: - dose keys ( single, turned on.
double)
The LED keys on the machine are turned off.
Grinding and enabling: - dose keys ( single, turned off.
It will automatically release when the enabled key is pushed or when the two minutes of waiting time elapse. double)
The associated keys will be enabled on the machine, which can be recognised by the relative LEDs lighting up.
13 EN
Check-control messages
key icon technical service
English
DEFECT
CAUSE
REMEDY
Carry out maintenance
After a certain number of cycles the Contact the technical service centre technical key icon appears on the as soon as possible. display on steady.
FLASH memory malfunction
CPU board malfunction. CPU board fault. The anomaly does not block the The fault is indicated by the technical key grinder/dispenser but the integrity of icon flashing with a frequency of 2Hz (. the stored data is not guaranteed. Consequently all stored parameters . .. .. .. .. . . ). could be corrupt or restored to factory settings. If, after restarting multiple times, the problem persists, contact the technical service centre.
Data integrity error in non-volatile Data integrity error whilst loading the non- The anomaly does not block the grinder/dispenser. However, normal memory volatile memory during start-up. The fault is indicated by the technical key operation is not guaranteed, as all icon flashing with a frequency of 1Hz (. stored parameters could be corrupt or restored to factory settings. ... .... .... . . . . ). If, after restarting multiple times, the problem persists, contact the technical service centre.
14 EN
A
B
C
5
IG
F
50mm
50mm
M2
MICRO SIC
50mm
M1
N
50mm
AC
AC
GND
faston 6.3
4
100mm
J6 LEOCO 5011S08000A
100mm
50mm
2 4 6 8 10
150mm
GND
MICRO-MATCH 10P
2 4 6 8 10
MOT
3
1 3 5 7 9
M2
N
2 4 6 8 10
2
A B C D
-
rosso bianco bianco nero
2
Date:
Description From TOLTO COLEGAMENTO POTENZIOMETRO MODIFICATO CON J6 Title INVERTITI PIN OUT 5-8 DEL CONN J6 (FASE SUL 5 E NEUTRO SUL 8) AGGIORNATO A COSTRUITO CON J6 Size A3 Conforme alle direttive: 2002/95/CE (Direttiva RoHS)
D
A
C
1 3 5 7 9
2 4 6 8 10 MICRO-MATCH 10P
J8
B
A
D
C
rosso-bianco nero-bianco
VERSIONE 115V
535793012
Isolare con termorestringente
B
bianco-bianco
VERSIONE 230V
1
Monday, November 07, 2011
Sheet 1
1
535793010 of
Cablaggio ENEA OnDemand Design File Name
<Title>
535793011
1
Rev A
FORNIRE IL CABLAGGIO IN VERSIONE 230V
500mm - GUAINA NERA 105° UL
D STYLE-1015 AWG18-BL
C STYLE-1015 AWG18-NE
B STYLE-1015 AWG18-BL
A STYLE-1015 AWG18-NE
MICRO SIC faston 6.3
F F N N F M
MICRO-MATCH 10P
J8
M1
J6 LEOCO -5011S08000A
Rev. Date 21/06/2011 A 1 21/07/2011 11/10/2011 A 07/11/2011
MATE-N-LOCK MASCHIO 3 POLI
1 3 5 7 9
FLAT 10P
F3 STYLE-1015 AWG18-NE
MOT MATE-N-LOK MASCHIO 3P
J7
N STYLE-1015 AWG18-BL
F1 STYLE-1015 AWG18-NE
N2 STYLE-1015 AWG18-BL
MICRO-MATCH 10P
J7
A - rosso B - bianco C - bianco D - nero
110mm
1 3 5 7 9
GND STYLE-1015 AWG18-GV2
Cod:965340000
N
faston 6.3
F
SW2 SW DPST AC
faston 6.3
AC
50mm
250mm
N GND
F
3
WIRING DIAGRAM
N STYLE-1015 AWG18-BL
4
1 3
D
CAVO ALIM
5
AC AC
AC
AC
F3A STYLE-1015 AWG18-N N2 STYLE-1015 AWG18-BL
AC
AC AC
AC
15 EN
AC
AC
AC
AC
AC
1 2 3 4 5 6 7 8
English
A
B
C
D
16 EN
A
B
C
D
5
60mm
MOT
60mm
60mm
140mm
N GND
AC
AC
GND
4
350mm
GND
GND STYLE-1015 AWG18-GV2
3
3
MOT MATE-N-LOK MASCHIO 3P
F F1 STYLE-1015 AWG18-NE AC faston 6.3 N STYLE-1015 AWG18-BL AC N faston 6.3
SW2 SW DPST
Cod:965340000
faston 6.3
AC
AB
Date
40mm
Description
M11
M21
M12
2
200mm
2
MICRO SIC faston 6.3
M22
MICRO 1 faston 4.8
Conforme alle direttive: 2002/95/CE (Direttiva RoHS)
Rev.
40mm
MICRO 1
F2 STYLE-1015 AWG18-NE
F1A STYLE-1015 AWG18-NE
F1A STYLE-1015 AWG18-NE
F1 STYLE-1015 AWG18-NE
WIRING DIAGRAM
90mm GUAINA NERA
IG
60mm
MATE-N-LOCK MASCHIO 3 POLI
F
AC
CAVO ALIM
4
1 3
AC
AC
5
AB
AC
AC
AC
From
60mm
1
Sheet
535792008 Monday, March 07, 2011
Date:
1
of
1
Rev
Cablaggio ENEA Mono F Design File Name
<Title>
535792001
60mm
Size A3
Title
1
535792002
MICRO SIC AC
English
AB
AB
AC
A
B
C
D
Il Costruttore si riserva il diritto di modificare senza preavviso le caratteristiche delle apparecchiature presentate in questa pubblicazione The Manufacturer reserves the right to modify the appliances presented in this publication without notice Le fabricant se réserve le droit de modifier sans préavis les caractéristiques des appareils présentés dans cette publication Der Hersteller behält sich das Recht vor, die in dieser Veröffentlichung vorgestellten Geräte ohne Vorankündigung zu ändern El Constructor se reserva el derecho de modificar sin preaviso las características de los equipos citados en este manual O Constructor reserva-se o direito de modificar sem aviso prévio as máquinas tratadas neste manual
GRUPPO CIMBALI SpA - 20082 BINASCO (MILANO) ITALY