Comstar Supply,
5 Blue Heron Drive Collegeville, PA 19426 Phone: 610-831-5020 Fax: 610-831-5012
INC
Think Cable... Think Comstar
1-866-326-6782
www.comstarsupply.com
Limited Warranty
USER'S GUIDE & SAFETY MANUAL
Condux International, Incorporated extends the following warranty to the original purchaser of these goods for use, subject to the qualifications indicated: Condux International, Incorporated warrants to the original purchaser for use that the goods or any component thereof manufactured by Condux International will be free from defects in workmanship for a period of one year from the date of purchase, provided such goods are installed, maintained, and used in accordance with Condux’s written instructions.
USER'S GUIDE & SAFETY MANUAL
Floor/Conduit/Pole Mount Frame
Components not manufactured by Condux International but used within the assembly provided by Condux International are subject to the warranty period as specified by the individual manufacturer of said component, provided such goods are installed, maintained, and used in accordance with Condux’s and the original manufacturer’s written instructions. Condux’s sole liability and the purchaser’s sole remedy for a failure of goods under this limited warranty, and for any and all claims arising out of the purchase and use of the goods, shall be limited to the repair or replacement of the goods that do not conform to this warranty. To obtain repair or replacement service under the limited warranty, the purchaser must contact the factory for a Return Material Authorization (RMA). Once obtained, send the RMA along with the defective part or goods, transportation prepaid, to: Condux International, Inc. 145 Kingswood Road Mankato, MN 56001 USA THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE. CONDUX ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY. CONDUX WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.
®
Condux International, Inc. P.O. Box 247 • 145 Kingswood Road, Mankato, MN 56002-0247 USA 1-507-387-6576 • 1-800-533-2077 • FAX 1-507-387-1442 Internet: http://www.condux.com © Copyright 1998, Condux International, Inc. Printed in USA Literature Part Number: 08674099 Revision Number: 1.0
5 Blue Heron Drive
Collegeville, PA 19426
®
(610) 831-5020
www.comstarsupply.com
Fax: (610) 831-5012
CONDUX
Comstar Supply,
5 Blue Heron Drive Collegeville, PA 19426 Phone: 610-831-5020 Fax: 610-831-5012
INC
Think Cable... Think Comstar
1-866-326-6782
www.comstarsupply.com
Floor Mounting Instructions
Conduit/Pole Mounting Instructions
1. Set the Floor/Conduit/Pole Mount Frame on the floor in line with the pull. 2. Secure the Floor/Conduit/Pole Mount Frame to the floor using concrete fasteners.
!CAUTION: Use the Floor/Conduit/Pole Mount Frame only on steel conduit or wood poles. Do not use on plastic, PVC, or fiberglass conduit or on aluminum or fiberglass poles.
5
⁄8" or larger
!WARNING: Properly install /8" or larger concrete fasteners. High pulling tensions could cause undersized or loose fasteners to fail. Severe personal injury or property damage could result. 5
3. Carefully set the power pack on the Floor/Conduit/Pole Mount Frame with the capstan side towards the pull.
Technical Specifications Part Number 08674005 08674010
2. Loosen mounting chain tightening handles. Place Pole Mounting Frame on the conduit or pole. Wrap the mounting chains around the conduit or pole & attach to the mounting frame.
6. Begin pulling slowly. If the Floor/Conduit/Pole Mount Frame or the power pack shifts or moves, stop pulling, release the pull-line tension, and remount the frame and power pack. Power pack
4. Attach a tie down chain to the mounting frame on the opposite side from the load. Securely attach the chain to an anchor point or wrap the chain around the wood pole (see Figures 2 & 3). !CAUTION: Always use a tie down chain of proper strength with the Conduit/Pole Mount Frame. 3/8" alloy link chain with integral hooks & 7,100 lb. working load capacity is recommended.
Figure 2. Steel Conduit Pole Mount Frame Rope
Power pack
Figure 1. Floor Mount Frame
ADVERTENCIA
Instrucciones de Operación
Figure 1. Conduit/Pole Mount Frame
!WARNING: Properly install 5⁄8" or larger concrete fasteners. High pulling tensions could cause undersized or loose fasteners to fail. Severe personal injury or property damage could result.
!WARNING: Do not exceed manufacturer’s rated load ratings for any pulling-line components. Severe personal injury or property damage could result.
!ADVERTENCIA: Favor de leer y comprender todas las instrucciones de operación y seguridad antes de usar el Condux CableGlider® Floor/Conduit/Pole Mount Frame. Si Ud. no comprende las instrucciones favor de consultarle a su jefe.
!WARNING: Do not pull up on the Floor Mount Frame. It is intended for use in horizontal pulls only. Severe personal injury or property damage could result.
!CAUTION: The Floor/Conduit/Pole Mount Frame & the power pack are heavy. Use proper lifting techniques or personal injury and property damage could result.
Collegeville, PA 19426
(610) 831-5020
www.comstarsupply.com
Power Pack
Conduit/Pole Mount Frame
Tie Down Chain
Figure 3. Wood Pole Mount Frame
!WARNING: Read and understand all procedure and safety instructions before using the Condux CableGlider® Floor/Conduit/Pole Mount Frame. Failure to do so may result in serious personal injury or property damage. Save this user’s guide for future reference.
5 Blue Heron Drive
Wood Pole
Pole Mount Frame
Wood Pole
Capstan
Concrete Fastener
Anchor Point
Rope
Mounting Chains
Floor Mount Frame
Conduit/Pole Mount Frame
Tie Down Chain
Power Pack
5. Place the CableGlider® Power Pack on the mounting frame & secure with the provided pins. 6. Slowly begin pulling with the power pack.
Mounting Pin
Steel Conduit
!WARNING: Do not pull up on the Floor Mount Frame. It is intended for use in horizontal pulls only. Severe personal injury or property damage could result.
Max Load Rating 5,000 lbs. 8,000 lbs.
Rope
Steel Conduit
5. Ensure the concrete fasteners and the mounting pins are secure before pulling.
Applications STD Puller Plus & HD Pullers
Table 1.
3. Fully tighten the chains by turning the tightening handles.
4. Lift the front end of the power pack and insert the front mounting pin. Do the same on the rear end of the power pack.
Capstan
1. Ensure the conduit or pole can withstand the maximum rated load of the Floor/Conduit/Pole Mount Frame (see Table 1).
Beware of electric utility lines. Failure to do so could result in severe personal injury or death. Always use a tie down chain of proper strength with the Conduit/Pole Mount Frame. 3/8" alloy link chain with integral hooks and 7,100 lb. working load capacity is recommended. If the frame slips or moves on the pole or conduit, stop the pull, release tension on the pull line, and remount the frame to the pole or conduit.
Fax: (610) 831-5012