BORNERAS EN EL TABLERO BOMBA 1

BORNERAS EN EL TABLERO BOMBA 2

3

2 4

4 5

6 6

15A

VA A BORNES XD: 23 - 24 DEL TAB. BOMBA 2

14A

14A

VIENE BORNES XD: 21 - 22 DEL TAB. BOMBA 2.

2

PRESOSTATO

1

100

VA A BORNE XD:1 TAB BOM.1 VA A BORNE XD:2 TAB BOM.1 VA A BORNE XD:3 TAB BOM.1 VA A BORNE XD:1 TAB BOM.2 VA A BORNE XD:2 TAB BOM.2 VA A BORNE XD:3 TAB BOM.2

7

13A

SEÑAL PRESOSTATO VA AL PLC

8

12A

7

11A

10A

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 H L T

SEÑAL FUNCIONAMIENTO REMOTO

9 10 11 12 13 14 15 16 17 18

9A

8

7

6

SEÑAL FUNCIONAMIENTO LOCAL

5

5

8A

SEÑAL APERTURA PUERTA

3

4

CONECTAR ELECTRODOS

1

1

3

105

15A BORNERAS EN EL TABLERO RECTIFICADOR

R 3 4 5

24VDC ALIMEN. SENSOR PRESION DESCARGA BOM 1

210

24VDC ALIMEN. SENSOR PRESION DESCARGA BOM 2

211

24VDC ALIMEN. SENSOR DE NIVEL

200 201 202 203

9 10 11 12 13 14 15 16 17 18 19 20

505

SEÑAL CARG. BATERIA OK

8

214

SEÑAL FUENTE 2 OK

7

213

SEÑAL FUENTE 1 OK

6

212

SEÑAL APERTURA PUERTA

2

24VDC ALIMEN. SENSOR PRESION IMPULSION

209

S 24V 0V 1

24VDC ALIMEN. MEDIDOR CAUDAL CONDUCCION

208

+ - + - + - + - + - + -

24VDC ALIMEN. MEDIDOR CAUDAL IMPULSION

207 502 503 504

9A

501

7

ALIMENT. SIST. CALEFACCION 220VAC T.T

ALIMENTACION TAB. BANCO DE BATERIAS

206

6

ALIMENT. SIST. VENTILACION 220VAC T.T

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

+ - + - + - + - + - + - + - + -

5

ALIMENTACION SIST. ILUMINACION 220VAC T.T

205

8

4

ALIMENTACION TOMACORRIENTE 220VAC T.T

ALIMENTACION 220 VAC

7

3

24VDC ALIMENT. SOLENOIDE BOMBA 2

204

6

24VDC ALIMENT. SOLENOIDE BOMBA 1

24VDC ALIMEN. TABLERO DE TELEMETRIA

5

ALIMENT. 24VDC SIST. RELES. PLC

203

BORNERAS EN EL TABLERO CONTROL

10A

SEÑAL FUNCIONAMIENTO MANUAL BOMBA 1

24VDC ALIMENTACION SIRENA

202

SEÑAL PARADA DE EMERGENCIA BOMBA 1

24VDC ALIM. SENSOR INTRUSO

201

SEÑAL PRESOSTATO

24VDC ALIMENTACION HMI

200

SEÑAL FUNCIONAMIENTO REMOTO T.G

Y

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35

SEÑAL FUNCIONAMIENTO LOCAL T.G

8

+ - + - + -

SEÑAL APERTURA PUERTA TABLERO GENERAL

ALIMENTACION 24VDC PLC

4

7

A

ALIMENT. SIST. ILUMINACION 220VAC T.C

3

ALIMENTACION TOMACORRIENTE 220VAC T.C

6

SEÑAL PARADA DE EMERGENCIA TAB. GENERAL

ALIMENT. SIST. CALEFACCION 220VAC T.C

2

5

+ -

SEÑAL CARG. BATERIA OK

ALIMENT. SIST. VENTILACION 220VAC T.C

1

4

8B

3

SEÑAL FUENTE 2 OK

X

Y

8A

2

8

210 211 212 213 214

24VDC ALIMENT. SOLENOIDE BOMBA 2

209

24VDC ALIMENT. SOLENOIDE BOMBA 1

208

ALIMENT. 24VDC SIST. RELES. PLC

9 10 11 12 13 14 15 16 17 18 19 20 21 22

+ - + - + - + - + - + - + -

24VDC ALIMENTACION SIRENA

207

7

24VDC ALIM. SENSOR INTRUSO

6

24VDC ALIMENTACION HMI

4

ALIMENTACION 24VDC PLC

206

5

ALIMENT. SIST. ILUMINACION 220VAC T.C

205

3

ALIMENTACION TOMACORRIENTE 220VAC T.C

204

ALIMENT. SIST. CALEFACCION 220VAC T.C

2

BORNERAS EN LA ESTACION CR - 195 MEJORADO

ALIMENT. SIST. VENTILACION 220VAC T.C

1

ENTRADA DISCRETA

VA A BORNES XD: 1 - 2 DEL TAB. BANC.COND.

BORNERAS EN EL TABLERO RECTIFICADOR

1

ENTRADA DISCRETA

SEÑAL APERTURA PUERTA

SEÑAL PARADA EMERGENCIA

X

ENTRADA DISCRETA

SEÑAL FUENTE 1 OK

500

ENTRADA DISCRETA

SEÑAL APERTURA PUERTA TR

107

SEÑAL SENSOR DE REBOSE

106

SEÑAL APERTURA PUERTA TABLERO DE BATERIAS

13B

SEÑAL APERTURA PUERTA TABLERO TELEMETRIA

ALIMENTACION SIRENA

24VDC ALIMENT. SOLENOIDE BOMBA 2

12B

SEÑAL FUNCIONA. BANCO CONDENS. BOMBA 2

ALIMENTACION 24VDC. SENSOR INTRUSO

24VDC ALIMENT. SOLENOIDE BOMBA 1

11B

SEÑAL APERTURA PUERTA BANCO CONDENS. BOMBA 2

ARRANQUE AUTOMATICO BOMBA 2

10B

SEÑAL APERTURA PUERTA BOMBA 2

ARRANQUE AUTOMATICO BOMBA 1

9B

SEÑAL RELE DE MAXIMA Y MINIMA TENSION BOMBA 2

102

SEÑAL FUNCIONAMIENTO AUTOMAT. BOMBA 2

101

SEÑAL FUNCIONAMIENTO MANUAL BOMBA 2

13A

SEÑAL PARADA DE EMERGENCIA BOMBA 2

12A

SEÑAL FUNCIONA. BANCO CONDENS. BOMBA 1

11A

SEÑAL APERTURA PUERTA BANCO CONDENS. BOMBA 1

36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73

SEÑAL APERTURA PUERTA BOMBA 1

13B

T

6

SEÑAL RELE DE MAXIMA Y MINIMA TENSION BOMBA 1

SEÑAL RELE MAXIMA Y MINIMA TENSION

BORNERAS EN EL TABLERO CONTROL

BORNERAS EN EL TABLERO CONTROL SEÑAL FUNCIONAMIENTO AUTOMAT. BOMBA 1

L

5

107

4

106

3

VIENE BORNES XD: 21 - 22 DEL TAB. BOMBA 1

SEÑAL FUNCIONAMIENTO AUTOMATICO

12B

H

2

105

1

SEÑAL BANCO CONDENSA FUNCIONANDO

VA A BORNES XD: 23 - 24 DEL TAB. BOMBA 1

SEÑAL FUNCIONAMIENTO MANUAL

11B

X

SEÑAL APERTURA PUERTA

CONECTAR ELECTRODOS

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

VA A BORNES XD: 1 - 2 DEL TAB. BANC.COND.

SEÑAL PARADA EMERGENCIA

10B

8

SEÑAL APERTURA PUERTA

2

7

SEÑAL FUNCIONAMIENTO AUTOMATICO

9B

6

SEÑAL FUNCIONAMIENTO MANUAL

8B

5

102

6

VIENE DE BORNES XD: 16 - 17 DEL TAB. BOMBA 2

ARRANQUE AUTOMATICO

4

SEÑAL PARADA EMERGENCIA

1

3

ARRANQUE AUTOMATICO

SEÑAL RELE MAXIMA Y MINIMA TENSION

BORNERAS EN EL TABLERO BANCO 2

2

2

4

101

5

100

3

SEÑAL APERTURA PUERTA

2

1

SEÑAL BANCO CONDENSA FUNCIONANDO

1

X VIENE DE BORNES XD: 16 -17 DEL TAB. BOMBA 1

VIENE BORNE XD:11 TAB GEN VIENE BORNE XD:12 TAB GEN VA BORNE XD:13 TAB GEN

X

X

X VIENE BORNE XD:14 TAB GEN VIENE BORNE XD:15 TAB GEN VA BORNE XD:16 TAB GEN

BORNERAS EN EL TABLERO BANCO 1

BORNERAS EN EL TABLERO GENERAL