BERNOULLI Redefining Air conditioning
#86,6th cross, B-sector, Amruthnagar, SahakarNagar Bangalore-560092 Mobile: +91 9535327298
Scope of work Package unit / Split unit Check Cleanness Check Any leakage Check Any abnormal vibration Check pipe insulation Check Bleed air from the system Check Calibrate thermometer and pressure gauge Check Power Voltage Check Running AMP Check Room temp Check Room humidity Compressor pressure Check Run hour of compressor Check Alarm Check Indicator lamp Check Buzzer CRAC setting Check Clean drain pans, pipes and hose Check Belt tension and alignment Check strainer Check oil level Check Main fan current Check Reheated current Check Compressor current Check Hi/Lo water level switch operation Check Main fan overload Check High pressure cut off switch Check High temp alarm Check Low temp alarm Check Low humidity alarm Check Coil condition Check Fan and motor panel interface Check Local monitor bearing lubrication Check pipe work insulation
Quarterly Quarterly Quarterly Yearly Yearly Yearly Quarterly Quarterly Monthly Monthly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Monthly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Quarterly Yearly Yearly Yearly Yearly
Valve check (fully close)
Yearly
BREAKDOWN CALLS: Any number of Breakdown calls will be attended free of cost. Downtime to attend a problem will be within 1 hour from the time of the complained received. All spares for the HVAC equipment will be supplied by Bernoulli EXCLUSIONS: 1. 2. 3. 4. 5. 6.
Repairs due to corrosion, if the equipment is installed in corrosive atmosphere. Insulation, false ceiling work and painting thereof. Sheet metal parts, storage tanks, insulation & plastic component. Any other item, which is not specifically spelt out under our scope of work. However, we will be able to carry out this work/supply these items on chargeable basis. All equipments like chiller, condenser, motors, VFD, Actuators and compressors are subject to REPAIR ONLY and NOT for replacement. AMC will be effective after through inspection and confirmation by our Service Team that the Chiller is in good working condition. Any repair required will be at additional cost.
USAGE: Abnormal usage/misuse/unauthorized attendance: a. Failure of equipment due to supply voltage beyond permitted range, phase unbalance, single phasing or fluctuating voltage or defects in your electrical installation, or abnormal usage or usage other than the equipment is originally designed for, misuse or due to atmospheric or due to action or hard/contaminated water, is not covered by this contract. b. Tampering with or repairs on the equipment at any time under any circumstances whatsoever by any one with exception of our authorized representative will render the contract null and void, without, prejudice to our rights. All failures resulting from the above will be rectified on additional charge basis.