81 .

GASES AND SMOKE

INFRARED GAS ANALYSER Ref.RY-500AG

DESCRIPTION The gas analyser is a modern device, prepared and ready to comply with the OIML class 1 and O, ISO 3930, UNE 82501, bar 90, bar 97, U.S. EPA ASM. The software allows two types of measurement:

1. Numerical measurement: it presents the gas concentration and the r.p.m. In numerical way.



2. Graphic measurement.

Based on infrared technology, it measures up to 5 gases (CO, CO2 HC, O2, NOx) and other parameters such as Lambda, corrected CO, oil temperature and r.p.m. It is very useful for starting and injection problems as well as for improvement of fuel consumption. The data base includes all car models and their emission values.

STANDARD EQUIPMENT Gas analyser module Sample drill Latest generation computer + Ink-jet printer Cabinet with TFT 19’’ adjustable screen Commom database (on network as well as in local mode) thats allows us to save all client and vehicle data and have easy access to them to be able to make comparisons between old and new bests. Translation module: all the net series comes with a translation module with which the user will be able to translate the program into his own language or modify any setence or word in it Temperature and r.p.m. tester.

TECHNICAL DATA Gas

CO, HC, CO2, O2 y (NOx optional)

Storing temperature

-50 ºC to 70 ºC

Working temperature

-5 ºC to 45 ºC

Operation pressure

750 - 1.100 mbar (1000 mbar nominal)

Automatic removal of water and hydro-carbide particles

>5 µ.

Voltage

220 V a 50 Hz

Temperature and r.p.m. tester.

r.p.m.: 0-9999 r.p.m.: 1 r.p.m.

TÉCNICAS REUNIDAS DE AUTOMOCIÓN - (+34) 947 482 020 - www.ryme.es - [email protected]

Lambda factor and corrected CO

It complies with the requirements UNE 82.501, OIML R 99 class 1 and 0, ISO 3930, BAR 90, BAR 97, U.S. EPA ASM. Database with rejection value limits

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

69

82 .

GASES AND SMOKE Ref.RY-500AG

OPTIONAL EQUIPMENT

MEASUREMENT AND RESOLUTION

GEN-MON Possibility of TFT screen in other sizes GEN-ST

Second terminal for the data visualitation, TFT screen, touch screen, PDA, Tablet PC...

GEN-ILC

Laser colour printer

GEN-SD

Diagnosis software to checks fault codes possible causes

GEN-RPM

Universal r.p.m. counter from vehicle lighter

AG-NOX

Sensor NOx

AG-AH

Smoke meter Kit

AG-2S

Double probe input

AG-ATE

Motorbikes kit

AG-CAL

Auto-calibration

AG-BOT

Gas bottles (pattern) for auto-calibration

GEN-NET

Configuration, Software and Ethernet Net installation

GEN-ONL

Internet connection for on-line after sales service

HC CO CO2 O2 NOx

0-20.000 p.p.m. 0-15 % vol. 0-20 % vol. 0-21,7 % vol. 0-5.000 p.p.m.

1 p.p.m 0,01 % vol. 0,1 % vol. 0,1 % vol. 1 p.p.m.

GEN-NET

GEN-ONL

AG-NOX

GEN-RPM AG-ATE

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

70

83 .

GASES AND SMOKE SMOKEMETER Ref.RY-500AH

DESCRIPTION The smoke meter is a modern device, prepared and ready to comply with the regulations UNE 82503 and DIN 57411, SAE J1677 USA / Canadá. It is a partial flow measurer based on the principle of the assorption of light by smoke. The software has two kinds of measurement:

- Free test: it allows us to do a continuous opacity test to observe the evolution of k in time.



- Official test: it allows us to do an official test guided by the program step by step.

Configuration: This function allows us to consult and modify the parameters of the test. Its access is restricted through a password as a safety measure by the authorised technical personnel. Red Ethernet connection: It allows us to send the measurement data to a central computer that receives and manages all the information obtained from several machines creating complete reports, as well as a database of vehicles and customers.

STANDARD EQUIPMENT Smokemeter module Sample probe Latest generation computer + Ink-jet printer Cabinet with TFT 19’’ adjustable screen Commom database (on network as well as in local mode) thats allows us to save all client and vehicle data and have easy access to them to be able to make comparisons between old and new bests. Translation module with which the user will be able to translate the program into his own language or modify andy sentence or word on it. Temperature and r.p.m. tester.

TECHNICAL DATA

Storing temperature Optical Detector Answering time Acustic noise Warm-up time Standard test band Opacity

Temperature: 5 - 40 ºC Humidity: 0-95 % Pollution: < 2 % -32 ºC a 50 ºC Light source green 56 mm. Photodiode of siliceo 0,5 ms. 53 dB 240 sg. 800 mm. 10 mm. Ø Range from 0 to 99,9 % Resolution 0,1

Temperature and r.p.m. tester.

Temperature = 0-150 ºC 0,1 ºC r.p.m. = 0-9999 r.p.m. 1 r.p.m.

Voltage

220 V. 50 Hz

TÉCNICAS REUNIDAS DE AUTOMOCIÓN - (+34) 947 482 020 - www.ryme.es - [email protected]

Environmental working conditions

OTHER INFORMATION Free measurement Official opacity test Measurement accuracy electronic test Equipment autodiagnosis It complies with the regulations: DIN 57.411, UNE 82.503, SAE J1677 US / CANADA Opacity measurement in % and in absortion coefficient k calculated according to Beer-Lambert

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

71

84 .

GASES AND SMOKE SMOKEMETER Ref.RY-500AH

OPTIONAL EQUIPMENT GEN-MON

Possibility of TFT screen in other sizes

GEN-ST

Second terminal for the data visualitation, TFT screen, touch screen, PDA, Tablet PC...

GEN-ILC

Laser colour printer

GEN-RPM

Universal r.p.m. counter from vehicle lighter

GEN-SAH

Extensible system for vertical exhaust systems

GEN-NET

Configuration, Software and Ethernet Net installation

GEN-ONL

Internet connection for on-line after sales service

GEN-NET

GEN-ONL

GEN-RPM

GEN-SAH

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

72

85 .

GASES AND SMOKE

Ref.RY-500AGH

INFRARED GAS ANALYSER AND SMOKEMETER

DESCRIPTION The gas analyser is a modern device, prepared and ready to comply with the OIML class 1 and O, ISO 3930, UNE 82501, bar 90, bar 97, U.S. EPA ASM. The software allows two types of measurement:

1. Numerical measurement: it presents the gas concentration and the r.p.m. In numerical way.



2. Graphic measurement.

Based on infrared technology, it measures up to 5 gases (CO, CO2 HC, O2, NOx) and other parameters such as Lambda, corrected CO, oil temperature and r.p.m. It is very useful for starting and injection problems as well as for improvement of fuel consumption. The data base includes all car models and their emission values. The smoke meter is a modern device, prepared and ready to comply with the regulations UNE 82503 and DIN 57411, SAE J1677 USA / Canadá. It is a partial flow measurer based on the principle of the assorption of light by smoke. The software has two kinds of measurement:

-Free test: it allows us to do a continuous opacity test to observe the evolution of k in time.



-O  fficial test: it allows us to do an official test guided by the program step by step.



-C  onfiguration: this function allows us to consult and modify the parameters of the test. Its access is restricted through a password as a safety measure by the authorised technical personnel.



-R  ed Ethernet connection: It allows us to send the measurement data to a central computer that receives and manages all the information obtained from several machines creating complete reports, as well as a database of vehicles and customers.

STANDARD EQUIPMENT TÉCNICAS REUNIDAS DE AUTOMOCIÓN - (+34) 947 482 020 - www.ryme.es - [email protected]

Smokemeter module Gas analyser module Sample probe Latest generation computer + Ink-jet printer Cabinet with TFT 19’’ adjustable screen Commom database (on network as well as in local mode) thats allows us to save all client and vehicle data and have easy access to them to be able to make comparisons between old and new bests. Translation module with which the user will be able to translate the program into his own language or modify andy sentence or word on it. Temperature and r.p.m. tester.

MEASUREMENT AND RESOLUTION INFRARED GAS ANALYSER HC CO CO2 O2 NOx

0-20.000 p.p.m. 0-15 % vol. 0-20 % vol. 0-21,7 % vol. 0-5.000 p.p.m.

1 p.p.m 0,01 % vol. 0,1 % vol. 0,1 % vol. 1 p.p.m.

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

73

86 .

GASES AND SMOKE

Ref.RY-500AGH

INFRARED GAS ANALYSER AND SMOKEMETER

TECHNICAL DATA INFRARED GAS ANALYSER Gas

CO, HC, CO2, O2 y (NOx opcional)

Lambda factor and corrected CO Storing temperature

-50 ºC a 70 ºC

Working temperature

-5 ºC a 45 ºC

Operation pressure

750 - 1.100 mbar (1000 mbar nominal)

Automatic removal of water and hydro-carbide

>5 µ.

Voltage

220 V a 50 Hz

Temperature and r.p.m. tester.

r.p.m.: 0-9999 r.p.m.: 1 r.p.m.

It complies with the requirements UNE 82.501, OIML R 99 class 1 and 0, ISO 3930, BAR 90, BAR 97, U.S. EPA ASM. Database and Rejection valuation

TECHNICAL DATA SMOKEMETER Environmental working conditions

Storing temperature Optical Detector Answer time Acustic noise Warm-up time Standard test band Opacity Temperature and r.p.m. tester.

Temperature: 5 - 40 ºC Humidity: 0-95 % Pollution: < 2 % -32 ºC a 50 ºC Light source green 56 mm. Photodiode of siliceo 0,5 ms. 53 dB 240 sg. 800 mm. 10 mm. Ø Range de 0 a 99,9 % Resolution 0,1 Temperature = 0-150 ºC 0,1 ºC r.p.m. = 0-9999 r.p.m. 1 r.p.m. 220 V. 50 Hz

Voltage Free measurement Official opacity test Measurement accuracy electronic test Equipment autodiagnosis It complies with the regulations: DIN 57.411, UNE 82.503, SAE J1677 US / CANADA

OPTIONAL EQUIPMENT GEN-MON

Possibility of TFT screen in other sizes

GEN-ST

Second terminal for the data visualitation, TFT screen, touch screen, PDA, Tablet PC...

GEN-ILC

Laser colour printer

GEN-SD

Diagnosis software to checks fault codes possible causes

GEN-RPM

Universal r.p.m. counter from vehicle lighter

GEN-SAH

Extensible system for vertical exhaust systems

AG-NOX

Sensor NOx

AG-2S

Double probe input

AG-ATE

Motorbikes kit

AG-CAL

Auto-calibration

AG-BOT

Gas bottles (pattern) for auto-calibration

GEN-NET

Configuration, Software and Ethernet Net installation

GEN-ONL

Internet connection for on-line after sales service

AG-NOX

AG-ATE

GEN-SAH

GEN-ONL Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

74

GEN-NET

87 .

GASES AND SMOKE EOBD

DESCRIPTION The mobile EOBD (European On Board Diagnostic) the most useful information and faulty codes of the vehicle from the computer. Characteristics: Complete test in 1 minute. Multi Car / Universal. Direct power feed from the car highter Automatic communication protocol connection R.p.m., speed, temperature..., mainboard access Faults codes memorized Lambda probe test, EGR, IAE, Catalytist... Big LCD screen.

STANDARD EQUIPMENT  onnection according to OBD II (SAE J962) C 5 communication ports: ISO 9141-2, ISO 14230(KWP2000), SAE J1850 VPW&PWM (ISO 11519-4), CAN (ISO15765), (European vehicles, American and Japonese). Test in metric system 12 ó 24 V. voltage Bright display. It supports various checks in the same BUS Weight 300 gr. According to SR/V/037 rule 01/01/2008.

CAP4120

Sole Bluetooth reader via RS232/USB plug conversor.

CAP4120-WIFI

Direct connection to WIFI router of the inspection centre

TÉCNICAS REUNIDAS DE AUTOMOCIÓN - (+34) 947 482 020 - www.ryme.es - [email protected]

AVAILABLE VERSIONS

CAP4120

CAP4120-WIFI

OPTIONAL EQUIPMENT EOBD-U

HEavy vehicle adaptor. J1939 protocol and cable included

EOBD-IMP

Bluetooth printer. Battery included

Due to the continual development of our products, technical characteristics and design may be subject to modifications without further notice.

75