Texas 2003 Cleanup Standards for Hydrocarbon Contaminated Groundwater Information from the Texas Risk Reduction Program can be found at Title 30, Texas Administrative Code, Chapter 350 or at http://www.tnrcc.state.tx.us Product Gasoline
Diesel
Waste Oil
Parameter/ Constituent BTEX
Lab Test Protocol & Number EPA 8021, 8260
Detection Level Notification Level * any amount
TPH PAHs BTEX TPH PAHs
TNRCC 1005 EPA 8100, 8270, 8310 EPA 8021, 8260 TNRCC 1005 EPA 8100, 8270, 8310
0.5mg/L * * 0.5mg/L *
BTEX TPH VOCs PAH
EPA 8021, 8260 TNRCC 1005 EPA 8260 EPA 8100, 8270, 8310
* 0.5mg/L * *
Action Level Cleanup Level **
site specific/risk-based
any amount any amount any amount any amount any amount
** ** ** ** **
site specific/risk-based site specific/risk-based site specific/risk-based site specific/risk-based site specific/risk-based
any amount any amount any amount any amount
** ** ** **
site specific/risk-based site specific/risk-based site specific/risk-based site specific/risk-based
* The method used must have a detection limit less the action level. If the action level is less than the method quantitation limit of the most sensitive standard available method, then the quantitaton limit of that method becomes the action level. ** The "action level" is the applicable protective concentration level(PCL). The PCL is established for each individual constituent. PCLs are not established for total BTEX, PAHs, or VOCs. PCLs for TPH are based on the specific composition of the TPH. Contact: Chris Chandler, Texas Commission on Environmental Quality, 512-239-2245 E-mail:
[email protected] Web Site: http://www.tceq.state.tx.us
Copyright © 2009 Association for Environmental Health and Sciences Foundation, Inc. 150 Fearing Street · Amherst, MA 01002 Phone: 413.549.5170 Fax: 413.549.0579 E-mail:
[email protected]
Texas 2003 Cleanup Standards for Hydrocarbon Contaminated Soil
Information from the Texas Risk Reduction Program can be found at Title 30, Texas Administrative Code, Chapter 350 or at http://www.tceq.state.tx.us Product
Parameter / Constituent
Lab Test Protocol & Number
Gasoline
BTEX
EPA 8021, 8260
TPH
TNRCC 1005
PAHs Diesel
Used Oil
Detection Level
Notification Level
Action Level
Cleanup Level
*
any amount
**
site specific/riskbased
50 mg/kg
any amount
**
site specific/riskbased
EPA 8100, 8270, 8310
*
any amount
**
site specific/riskbased
BTEX
EPA 8021, 8260
*
any amount
**
site specific/riskbased
TPH
TNRCC 1005
50 mg/kg
any amount
**
site specific/riskbased
PAHs
EPA 8100, 8270, 8310
*
any amount
**
site specific/riskbased
BTEX
EPA 8021, 8260
*
any amount
**
site specific/riskbased
TPH
TNRCC 1005
50 mg/kg
any amount
**
site specific/riskbased
PAHs
EPA 8100, 8270, 8310
*
any amount
**
site specific/riskbased
VOCs
EPA 8260
*
any amount
**
site specific/riskbased
* The method used must have a method quantitation limit less than the action level. If the action level is less than the method quantitation limit of the most sensitive standard available method, then the quantitation limit of that method becomes the action level. ** The "action level" is the applicable protective concentration level(PCL). The PCL is established for each individual constituent. PCLs are not established for total BTEX, PAHs, or VOCs. PCLs for TPH are based on the specific composition of the TPH. Contact: Chris Chandler, Texas Commission on Environmental Quality, 512-239-2245 E-mail: