working documents as built

SAACKE VKK Marine Boilers GmbH

protection note according to DIN 34 consider !

operating voltage

: 440V/60 Hz

Betriebsspannung

Kaiserstrasse 4 24143 Kiel / Germany

control voltage

: 230V/60 Hz

Steuerspannung signal voltage

: 24V/DC

Signalspannung regulation Vorschrift degree of protection Schutzart

Power input

phone :

+49 (0) 431 7303 0

fax :

+49 (0) 431 7303 303

e-mail :

[email protected]

internet :

www.vkkmb.de

: LR ETS 25775-11

electrical documentation

: IP 54

Elektro-Dokumentation

22 KW / 50 A max

fuse

63 A contract number

Colour :Munsell 7.5 BG 7/2

PCS

Control cabinet

1

PID BN 001 CS010

Dimension H 1800 x W 1600 x D 400 + 100mm socket

1

project

FO / FW/ MGO pumps

0

as built

R. modification

2012-01-30

drawn

ROS

check

2012-01-30

30.01.2012

ROS

date

name standard

H 380x W 380 x D 210

6

:

CMB-VS-1.6+1.0/7

:

NEW TIMES SY

:

SKVJ-M 14

Projektkommentar

Brennertyp cover sheet / Deckblatt 1

Control Cabinet Boiler origin

0-8100-100454-14 /3-32

Projekt

type of burner

Local switch boxes

date

CS010

:

Zeichnungsnummer

comment on project Starter box FWP 2

100454 HN: 0108216

Auftragsnummer drawing number

Cabinet

:

replaced for

replaced by

general informations / allgemeine Informationen

0-8100-100454-14 /3-32

=BCC +CC

0-8100-100454-14-3

sheet 1 6

sh.

1

2

A

3

4

5

6

7

8

A

The regulation of the acceptance associations have to be considered Use approved materials and equipment only

1.)

Grounding of the casing (base, door, console panel, etc.)

13.)

Screw which cannot be lost are to be used for plug-in modules.

14.)

All labels are additionally to be fastened with grooved rails

earthing cable min. 16mm²

2.)

Grounding to be carried out via cable lugs only, screws = M6

or screws (Gravopley labels).

B 3.)

Doors of control boxes and control cabinets a accommodating control and annunciating equipment must be provided with a locking divice and with

C

E

When installing unions in flange plates not processed or finished the area of the unions has to be made metallically bare and is to be greased.

5.)

Use standard parts with processed surface (disks, lock washers, spring lock washers, etc.)

6.)

Electric control equipment for more than one boiler has to be erected apart and must be mechanically separated (partition). This is applicable too for the shared oil supply system.

7.)

When using cable ducts the supply line may only be arranged in a separate cable duct or must remain visible.

8.)

Application of vibration immune screw caps with verifying hole is imperative.

9.)

15.)

BV requires wires with heavy insulation for all lines above 230V up to 16²

16.)

DNV requires wires with heavy insulation for all lines up to 16²

17.)

The control cabinet is to be equipped with fasting strips.

18.)

Mounting plate, cabinet door and back wall are to be reinforced.

19.)

Use non halogen lines

20.)

Use non halogen cable duct

21.)

wiring control voltage >50V without indication cross section with H05Z-K 1,0 mm²

22.)

Tension spring terminals client side. (Cutting terminals internally internal sid

23.)

Protect equipment against shift

24.)

Startype equipment grounding

25.)

The control cabinet bottom has to be equipped with isolated

Separating disks are to be provided between terminals with

C

and pierced copper busbar for connection cable shilding.

26.) 10.)

Install cable pull relief bar so that cables can be fitted directly.

All equipment labels on the mounting plates are to be coated additionally with transparent lacquer (paper labels)

27.)

Copper busbars for cable shilding have to be isolated und equipped with clips for external cables.

11.)

All lines are to be labeled. Cable harnesses must be tied up in bundles.

12.)

D

Colour of cores

different potentials. The voltage of the terminals must be labeled.

all lines without indication of cross section are

D

4.)

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

an equipment cover for equipment not contact-protected.

B

Control transformers must by all means be grounded via cable.

L1

Green

L2

Yellow

L3

Brown

PE

green / Yellow

230 VAC (L)

Black

230 VAC (N)

Light Blue

24 V DC (+)

Red

24 V DC (-)

Blue

E

Measuring Cable

White

Extern

Orange

Voltage

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

cover sheet / Deckblatt 2

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 2

0-8100-100454-14-3

design specification / Bauvorschrift 5

=BCC

6

7

6 8

sh.

1

2

X0:

3

4

5

=BCC :

terminal strip for external items equipment >230V

X1:

=ECR :

terminal strip for external items equipment 230V

=MSB1 :

terminal strip for external items equipment <230V

engine control room

+F :

main switch board 1

+BO :

=MSB2 :

terminal strip for external items equipment analoge signals

X6:

main switch board 2

+BW :

Hauptschalttafel 2 +BN :

terminal strip for volt free contacts

terminal strip for "volt free" analog signals

protection note according to ISO 16016 consider!

E

+FWP2 :

terminal strip for control and indication equipment >50V

+.._B :

junction box burner

equipment at cabinet bottom plate Geräte in der Bodenplatte

burner equipment

local operation box electrical pre heater

local operation box feed water pump 1

local operation box feed water pump 2 Vor-Ort-Bedienkasten Speisewasserpumpe 2

+FOP1 :

terminal strip for control and indication equipment <50V

local operation box oil pump 1 Vor-Ort-Bedienkasten Ölpumpe 1 C

+FOP2 :

terminal strip for control and indication equipment analoge signals

local operation box oil pump 2 Vor-Ort-Bedienkasten Ölpumpe 2

+MGOP1 : X111:

Geräte in den Seitenwänden

Vor-Ort-Bedienkasten Speisewasserpumpe 1

Klemmenleiste für Befehls- und Meldegeräte analoge Signale terminal strip for control cabinet ventilation

local operation box MGO pump 1 Vor-Ort-Bedienkasten MGO pumpe 1

Klemmenleiste für Schaltschrankbelüftung +MGOP2 : X601:

terminal strip for data transfer to +ECR

local operation box MGO pump 2 Vor-Ort-Bedienkasten MGO pumpe 2

Klemmenleiste für Datenübertragung zum ECR -Raum

D

example circuits: Beispiel Strompfade: /12.7 *sheet-No.

all lines without indication of cross section are

D

+FWP1 :

terminal strip for control and indication equipment >230V

Klemmenleiste für Befehls- und Meldegeräte <50V X13:

equipment at cabinet side walls

Vor-Ort-Bedienkasten Elektrovorwärmer

H07Z-K 1,5mm²

C

+.._S :

boiler equipment

B +CEP :

Klemmenleiste für Befehls- und Meldegeräte >50V X12:

equipment in cabinet door

Brennergeräte

Klemmenleiste für Befehls- und Meldegeräte >230V X11:

equipment on mounting plate

Geräte in Schaltschranktür

Anschlußkasten Brenner

Klemmenleiste für "potentialfreie" analoge Signale X10:

+.._D :

field equipment

Kesselgeräte

Klemmenleiste für potentialfreie Kontakte

B

8

Geräte auf der Montageplatte

Feldgeräte

Hauptschalttafel 1

Klemmenleiste für analoge Signale X4:

+.._M :

control unit Steuerteil

Maschinenkontrollraum

Klemmenleiste für außenliegende Geräte <230V X3:

7

A

Klemmenleiste für außenliegende Geräte 230V X2:

+CC :

Kessel

Klemmenleiste für außenliegende Geräte >230V

A

boiler

6

*Blatt-Nr. Strompfad-Nr.

13

14

21

22

31

32

43

44 E

circuit-No.

modification index / Änderungsindex a = b...z= 0 = 1...30 =

*Die Angabe entfällt,

*this indication

first issue

erste Ausgabe

wenn Schütz und

is not required

modifications before delivery

Änderung vor Auslieferung

Kontakt auf dem

where the contactor

as built

Auslieferungszustand

gleichem Blatt vor-

and contact exist

modification after delivery

Änderung nach Auslieferung

handen sind.

on the same sheet.

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

cover sheet / Deckblatt 3

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 3

0-8100-100454-14-3

legend / Zeichenerklärung 5

=BCC

6

7

6 8

sh.

1

2

3

4

5

6

7

8

+BN001

A

Junction box

control unit

Klemmenkasten

Steuerteil

=BCC

Pumps / drives boiler A

CS010

+BW

BCC_1004 (M4G2,5)

Flame scanner 1

BCC_4001 (M5x0,75SH)

Flame scanner 2

BCC_4002 (M5x0,75SH)

=BCC +CC

BCC_1005 (M4G1,5) M

+BN020-2M3 ignition oil pump

BCC_1003 (M4G4) M

+BN001-2M5 combustion air fan

M

+FO001 -3M3 fuel oil pump 2

BCC_1010 (M4G1,5) M Poti- contr.valve

+FO001 -3M2fuel oil pump 1

BCC_4011 (M3x0,75SH) BCC_1011 (M4G1,5)

BCC_2005 (M 16G1,5) BCC_3005 (M 12G1,5)

B

B

C

E

M

M

+FW001 -4M2 feed water pump 1

+FW008-5M2 chemical dosing pump +FO 001

Heater box Burner

local switch box

BCC_1012 (M4G4)

BCC_2120 (M7G1,5)

=BCC +BN

fuel oil pump 1

Heater

BCC_2022 (M4G1,5)

C

+FO 002

CS062

Heater Control

local switch box BCC_2121 (M7G1,5)

fuel oil pump 2 CS062 +FW 001 local switch box

BCC_2220 (M7G1,5)

feed water pump 1 CS061

MSB 1

BCC_2222 (M7G1,5)

BCC_1000 (M4G25)

D

+BCCFWP2

MSB 2

BCC_1007(M4G2,5) BCC_1001 (M4G25) BCC_1002 (M4G4)

all lines without indication of cross section are

D

BCC_2020 (M3G1,5)

+BN001

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

BCC_1006 (M4G2,5)

starter box

M

+FW001 -4M3 feed water pump 2

feed water pump 2 CS010

E

+FW 002 local switch box BCC_2221 (M7G1,5)

feed water pump 2 CS061

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

cover sheet / Deckblatt 5

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 5

0-8100-100454-14-3

cable overview / Kabelübersicht 5

=BCC

6

7

6 8

sh.

1

2

3

4

5

6

control unit

Sensors

Steuerteil

+F -9S2 emergenca stop 1 escape route A

BCC_3001 (M2X1,5) S

BN 001

+F -9S3 emergency stop 2 escape route

BCC_3006 (M2X1,5) PSH

CS 010 =BCC

7

boiler A

+BO034 -52F2 pressure monitor boiler

BCC_3007 (M2X1,5) TSH

+CC BCC_3002 (M2X1,5)

8

BCC_4000 (M 2X0,75SH)

PT

+BO041 -53F2temperature monitor flue gas

+BO033-64B2 transmitter steam pressure

S Push button " emegency stop " only option Yard supply in case of using

B

B

BCC_4003 (M 4 X0,75SH)

LSL

+BO022-69B3 level monitor 1 boiler water

C

E

+BO021 -68B2 level transmitter boiler water

C

BCC_3014 (M2X1,5) PSL BCC_3016 (M2X1,5)

BCC_3008

PSL

+FO003-55S2/55S3 limit switch

(M4X1,5)

BCC_3010 (M4X1,5)

GS

3-way valve return line D

+FO002-56S2/57S2

limit switch 3-way valve return line HFO / MDO

BCC_3012 (M4X1,5)

control room

+FO006-16F7 pressure monitor fuel oil pump

+FW005-19F7 pressure monitor feed water pump 1

GS

GS

+BN010 -56S3/57S3 limit switch 3-way valve pressure controller HFO / MDO

Leitstand =ECR

remote indicator

PT Boiler CS 080

BCC_6001 (M5X1,5SH)

LT Boiler CS 081

all lines without indication of cross section are

D

LT

BCC_2006 (M 2x1,5)

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

BCC_4005 (M2X0,75SH)

BCC_2008 (M5G1,5) volt free contacts

GS

BCC_6010 (M24X1,5)

E

+CO 011-77A2 oil detector device

BCC_6011 (M24X1,5) BCC_6012 (M18X1,5)

MGO

BCC_6013 (M18X1,5)

BCC_2009 (M4G1,5)

QS

+FW007-76A3 conductivity device

BCC_6014 (M18X1,5) BCC_4099(M2x0,75SH)

GS

conductivity electrode

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

cover sheet / Deckblatt 6

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 6

0-8100-100454-14-3

cable overview / Kabelübersicht 5

=BCC

6

7

6 8

sh.

1

2

3

4

5

control unit A

M

A

+GO001 -3M5 MGO pump 1

BCC_1009 (M4G1,5)

BCC_3018 (M2X1,5)

BCC_3020

M

PSL

+GO001 -3M7 MGO pump 2

+GD 006 -23F7 pressure monitor MGO pump

(M4X1,5) GS

BCC_3021 (M4X1,5)

B

8

BCC_1008 (M4G1,5)

=BCC +CC

7

MGO pump

Steuerteil CS 010

6

GS

+GO 015-59S2/59S5

limit switch 3-way valve HFO / MDO B

+GO 016 -59S3/59S6

limit switch 3-way valve MGO

+GO 001

C

+GO 002

CS062 local switch box BCC_2123 (M7G1,5)

MGO pump 2 CS062 C

D

all lines without indication of cross section are

D

MGO pump 1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

local switch box BCC_2122 (M7G1,5)

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

cover sheet / Deckblatt 7

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 7

0-8100-100454-14-3

cable overview / Kabelübersicht 5

=BCC

6

7

6 8

sh.

directory no.

1

2

3

4

5

protection note according to ISO 16016 consider!

6

kind of plan

sheet no.

cover sheet / Deckblatt

1

cover sheet / Deckblatt

design specification / Bauvorschrift

3

cover sheet / Deckblatt

legend / Zeichenerklärung

5

cover sheet / Deckblatt

cable overview / Kabelübersicht

6

cover sheet / Deckblatt

special notes

general informations / allgemeine Informationen

2

cover sheet / Deckblatt

sheet designation

cable overview / Kabelübersicht

7

cable overview / Kabelübersicht

drawn

revision

date

date

ROS

a

2012-01-30

25.07.2011

ROS

a

2012-01-30

25.07.2011

ROS

a

2012-01-30

25.07.2011

ROS

a

2012-01-30

25.07.2011

ROS

a

2012-01-30

25.07.2011

ROS

a

2012-01-30

25.07.2011

ROS

7

directory / Inhaltsverzeichnis

1

8

directory / Inhaltsverzeichnis

2

9

directory / Inhaltsverzeichnis

3

10

directory / Inhaltsverzeichnis

4

11

directory / Inhaltsverzeichnis

5

12

directory / Inhaltsverzeichnis

6

13

circuit diagram / Stromlaufplan

1

power supply / Einspeisung

14

circuit diagram / Stromlaufplan

2

burner oil pumps

15

circuit diagram / Stromlaufplan

3

fuel oil pumps

16

circuit diagram / Stromlaufplan

4

feed water pumps

17

circuit diagram / Stromlaufplan

5

electrical heater/ chemical dosing pump

18

circuit diagram / Stromlaufplan

7

230V supply

19

circuit diagram / Stromlaufplan

8

230V supply

20

circuit diagram / Stromlaufplan

9

emergency stop

21

circuit diagram / Stromlaufplan

10

control voltage

22

circuit diagram / Stromlaufplan

11

24VDC supply

23

circuit diagram / Stromlaufplan

12

firing sequence control

24

circuit diagram / Stromlaufplan

13

PLC S7 200

25

circuit diagram / Stromlaufplan

14

PLC S7-200

26

circuit diagram / Stromlaufplan

15

PLC S7-200

27

circuit diagram / Stromlaufplan

16

FOP control

28

circuit diagram / Stromlaufplan

17

fuel oil pump 1

29

circuit diagram / Stromlaufplan

18

fuel oil pump 2

30

circuit diagram / Stromlaufplan

19

FWP control

2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 23.07.2011 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 23.07.2011 ROS 23.07.2011 ROS 2012-01-30

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 1

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 1 7

sh.

directory

protection note according to ISO 16016 consider!

no.

kind of plan

sheet no.

sheet designation

31

circuit diagram / Stromlaufplan

20

feed water pump 1

32

circuit diagram / Stromlaufplan

21

feed water pump 2

33

circuit diagram / Stromlaufplan

22

feed water pump 2

34

circuit diagram / Stromlaufplan

23

MGO control

35

circuit diagram / Stromlaufplan

24

MGO pump 1

36

circuit diagram / Stromlaufplan

25

MGO pump 2

37

circuit diagram / Stromlaufplan

27

dosing pump

38

circuit diagram / Stromlaufplan

28

electrical preheater

39

circuit diagram / Stromlaufplan

29

common inputs

40

circuit diagram / Stromlaufplan

30

burner motor control

41

circuit diagram / Stromlaufplan

31

safety interlock circuit

42

circuit diagram / Stromlaufplan

32

safety interlock circuit

43

circuit diagram / Stromlaufplan

33

safety interlock circuit

44

circuit diagram / Stromlaufplan

34

emergency operation

45

circuit diagram / Stromlaufplan

35

burner start

46

circuit diagram / Stromlaufplan

36

burner reset

47

circuit diagram / Stromlaufplan

37

ignition system

48

circuit diagram / Stromlaufplan

38

oil valves

49

circuit diagram / Stromlaufplan

39

flame detection 1

50

circuit diagram / Stromlaufplan

40

flame detection 2

51

circuit diagram / Stromlaufplan

41

flame detection

52

circuit diagram / Stromlaufplan

42

firing sequence control

53

circuit diagram / Stromlaufplan

43

firing sequence control

54

circuit diagram / Stromlaufplan

44

primary air pressure

55

circuit diagram / Stromlaufplan

45

combustion air pressure

56

circuit diagram / Stromlaufplan

46

burner swung out

57

circuit diagram / Stromlaufplan

47

limit switch compund regulator

58

circuit diagram / Stromlaufplan

48

fire in windbox

59

circuit diagram / Stromlaufplan

49

oil pressure

60

circuit diagram / Stromlaufplan

50

HFO temperature

special notes

drawn

revision

date

date

ROS 23.07.2011 ROS 23.07.2011 ROS 2012-01-30 ROS 2012-01-30 ROS 23.07.2011 ROS 23.07.2011 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 2

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 2 7

sh.

directory

protection note according to ISO 16016 consider!

no.

kind of plan

sheet no.

sheet designation

61

circuit diagram / Stromlaufplan

51

HFO temperature high

62

circuit diagram / Stromlaufplan

52

steam pressure

63

circuit diagram / Stromlaufplan

53

flue gas temperature

64

circuit diagram / Stromlaufplan

54

heating tracer

65

circuit diagram / Stromlaufplan

55

selection fuel

66

circuit diagram / Stromlaufplan

56

selection fuel

67

circuit diagram / Stromlaufplan

57

selection fuel

68

circuit diagram / Stromlaufplan

59

selection fuel oil MGO

69

circuit diagram / Stromlaufplan

60

load control

70

circuit diagram / Stromlaufplan

61

load control

71

circuit diagram / Stromlaufplan

62

load control

72

circuit diagram / Stromlaufplan

63

alarm steam pressure

73

circuit diagram / Stromlaufplan

64

steam pressure

74

circuit diagram / Stromlaufplan

68

boiler water level

75

circuit diagram / Stromlaufplan

69

low low water 1

76

circuit diagram / Stromlaufplan

70

low low water 2

77

circuit diagram / Stromlaufplan

73

alarms control boiler level

78

circuit diagram / Stromlaufplan

74

alarms control boiler level

79

circuit diagram / Stromlaufplan

76

conductivity minitoring

80

circuit diagram / Stromlaufplan

77

oil monitoring

81

circuit diagram / Stromlaufplan

90

ilumination door 1 ( left)

82

circuit diagram / Stromlaufplan

92

ilumination door 2 ( right)

83

circuit diagram / Stromlaufplan

100

volt free contacts

84

circuit diagram / Stromlaufplan

101

volt free contacts

85

circuit diagram / Stromlaufplan

102

volt free contacts

86

circuit diagram / Stromlaufplan

103

volt free contacts

87

circuit diagram / Stromlaufplan

104

volt free contacts

88

terminalblock diagram / Klemmenplan

1

=BCC+CC_M-X0

89

terminalblock diagram / Klemmenplan

2

=BCC+CC_M-X0

90

terminalblock diagram / Klemmenplan

3

=BCC+CC_M-X1

special notes

drawn

revision

date

date

ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 3

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 3 7

sh.

directory

protection note according to ISO 16016 consider!

no.

kind of plan

sheet no.

sheet designation

91

terminalblock diagram / Klemmenplan

4

=BCC+CC_M-X1

92

terminalblock diagram / Klemmenplan

5

=BCC+CC_M-X2

93

terminalblock diagram / Klemmenplan

6

=BCC+CC_M-X2

94

terminalblock diagram / Klemmenplan

7

=BCC+CC_M-X3

95

terminalblock diagram / Klemmenplan

8

=BCC+CC_M-X4

96

terminalblock diagram / Klemmenplan

9

=BCC+CC_M-X4

97

terminalblock diagram / Klemmenplan

10

=BCC+CC_M-X6

98

terminalblock diagram / Klemmenplan

11

=BCC+CC_M-X10

99

terminalblock diagram / Klemmenplan

12

=BCC+CC_M-X11

100

terminalblock diagram / Klemmenplan

13

=BCC+CC_M-X12

101

terminalblock diagram / Klemmenplan

14

=BCC+CC_M-X19

102

terminalblock diagram / Klemmenplan

15

=BCC+CC_M-X20

103

terminalblock diagram / Klemmenplan

16

=BCC+CC_M-X21

104

terminalblock diagram / Klemmenplan

17

=BCC+CC_M-X30

105

terminalblock diagram / Klemmenplan

18

=BCC+CC_M-X31

106

terminalblock diagram / Klemmenplan

19

=BCC+CC_M-X40

107

terminalblock diagram / Klemmenplan

20

=BCC+CC_M-X41

108

terminalblock diagram / Klemmenplan

21

=BCC+CC_M-X111

109

terminalblock diagram / Klemmenplan

22

=BCC+CC_M-XPE

110

terminalblock diagram / Klemmenplan

23

=BCC+BW-X1.1

111

terminalblock diagram / Klemmenplan

24

=BCC+BW-X2.1

112

terminalblock diagram / Klemmenplan

25

=BCC+BW-X3.1

113

terminalblock diagram / Klemmenplan

26

=BCC+BW-X3.2

114

terminalblock diagram / Klemmenplan

27

=BCC+BW-X3.3

115

terminalblock diagram / Klemmenplan

28

=BCC+BW-X8

116

terminalblock diagram / Klemmenplan

29

=BCC+BW-X8

117

terminalblock diagram / Klemmenplan

30

=BCC+ECR-X

118

terminalblock diagram / Klemmenplan

31

=BCC+ECR-X

119

terminal connection diagram / Anschlussplan

1

=BCC+CC_M-X0

120

terminal connection diagram / Anschlussplan

2

=BCC+CC_M-X1

special notes

drawn

revision

date

date

ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 25.07.2011 ROS 07.12.2011 ROS 07.12.2011

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 4

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 4 7

sh.

directory

protection note according to ISO 16016 consider!

no.

kind of plan

sheet no.

sheet designation

special notes

drawn

revision

date

date

ROS

121

terminal connection diagram / Anschlussplan

3

=BCC+CC_M-X1

122

terminal connection diagram / Anschlussplan

4

=BCC+CC_M-X2

123

terminal connection diagram / Anschlussplan

5

=BCC+CC_M-X2

124

terminal connection diagram / Anschlussplan

6

=BCC+CC_M-X3

125

terminal connection diagram / Anschlussplan

7

=BCC+CC_M-X3

126

terminal connection diagram / Anschlussplan

8

=BCC+CC_M-X4

127

terminal connection diagram / Anschlussplan

9

=BCC+CC_M-X4

128

terminal connection diagram / Anschlussplan

10

=BCC+CC_M-X6

129

terminal connection diagram / Anschlussplan

11

=BCC+CC_M-X20

130

terminal connection diagram / Anschlussplan

12

=BCC+CC_M-X21

131

terminal connection diagram / Anschlussplan

13

=BCC+CC_M-X30

132

terminal connection diagram / Anschlussplan

14

=BCC+CC_M-X31

133

terminal connection diagram / Anschlussplan

15

=BCC+CC_M-X40

134

terminal connection diagram / Anschlussplan

16

=BCC+CC_M-X41

135

terminal connection diagram / Anschlussplan

17

=BCC+CC_M-XPE

136

terminal connection diagram / Anschlussplan

18

=BCC+BCCFWP2-X0

137

terminal connection diagram / Anschlussplan

19

=BCC+BCCFWP2-X1

138

layout diagram / Aufbauplan

1

front view / Frontansicht

139

layout diagram / Aufbauplan

2

legend door 2 / Legende Tür 2

140

layout diagram / Aufbauplan

3

control cabinet / Schaltschrank

141

layout diagram / Aufbauplan

4

control cabinet / Schaltschrank

142

layout diagram / Aufbauplan

5

base control cabinet / Sockel Schaltschrank

143

layout diagram / Aufbauplan

8

bore holes / Bohrungen

144

layout diagram / Aufbauplan

9

base control cabinet / Sockel Schaltschrank

145

layout diagram / Aufbauplan

10

bore holes / Bohrungen

146

layout diagram / Aufbauplan

11

mounting plate / Montageplatte

147

layout diagram / Aufbauplan

11.1

mounting plate / Montageplatte

148

layout diagram / Aufbauplan

12

lables / Schilder

149

layout diagram / Aufbauplan

20

front view / Frontansicht Starterbox FWP2

150

layout diagram / Aufbauplan

21

lables Starterbox FWP 2

07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 07.12.2011 ROS 23.07.2011 ROS 23.07.2011 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 23.07.2011 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 5

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 5 7

sh.

directory

protection note according to ISO 16016 consider!

no.

kind of plan

sheet no.

sheet designation

special notes

151

layout diagram / Aufbauplan

22

front view / Frontansicht Starterbox FWP 2

152

layout diagram / Aufbauplan

23

bore holes / Bohrungen Feed water pump 2

153

layout diagram / Aufbauplan

24

mounting plate / Montageplatte FW pump 2

154

layout diagram / Aufbauplan

25

mounting plate / Montageplatte FW pump 2

155

layout diagram / Aufbauplan

26

mounting plate / Montageplatte FW pump 2

156

layout diagram / Aufbauplan

27

wall mountig holders Starterbox FWP 2

157

item list / Geräte-Stückliste

1

158

item list / Geräte-Stückliste

2

159

item list / Geräte-Stückliste

3

160

item list / Geräte-Stückliste

4

161

item list / Geräte-Stückliste

5

162

item list / Geräte-Stückliste

6

163

item list / Geräte-Stückliste

7

164

item list / Geräte-Stückliste

8

165

item list / Geräte-Stückliste

9

166

item list / Geräte-Stückliste

10

167

item list / Geräte-Stückliste

11

168

item list / Geräte-Stückliste

12

169

item list / Geräte-Stückliste

13

170

item list / Geräte-Stückliste

14

171

item list / Geräte-Stückliste

15

172

item list / Geräte-Stückliste

16

173

item list / Geräte-Stückliste

17

174

item list / Geräte-Stückliste

18

175

item list / Geräte-Stückliste

19

176

item list / Geräte-Stückliste

20

177

item list / Geräte-Stückliste

21

178

item list / Geräte-Stückliste

22

179

item list / Geräte-Stückliste

23

180

item list / Geräte-Stückliste

24

drawn

revision

date

date

ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 6

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 6 7

sh.

directory no.

kind of plan

sheet no.

item list / Geräte-Stückliste

25

182

cable list / Kabelliste

1

183

cable list / Kabelliste

2

184

cable list / Kabelliste

3

special notes

drawn

revision

date

date

ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30 ROS 2012-01-30

protection note according to ISO 16016 consider!

181

sheet designation

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

directory / Inhaltsverzeichnis 7

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 7 7

sh.

1

2

3

4

5

6

7

8

L1 L2

3

5

4

6

3 4

C 21 A1

-1K6

A2

-2L3

6 5 16 mm2

4 3 16 mm2 -2L2

2 1 16 mm2 -2L1

A2

-1K3

22

4

2 22

-1L3

21 5 16 mm2

-1L2

A1

6

3

4

1

+CC_D

16 mm2

2

-1Q5

16 mm2

+CC_D

B

3

Hauptschalter

-1L1

-1Q2

22

31

32

-BCC_1001

43

44

M4G35

53

54

GNYE

/100.5

-X

-X

+MSB1

+MSB2

power supply 1

3

4

5

6

13

14

21

22

31

32

43

44

53

54 E

PE

power supply 2

Einspeisung

PE

21

/92.6

3

PE

14

5

2

PE

13

5

1

PE

1PE

1L3

1L2

/100.5

6

2PE

M4G25

4

5

PE 5

2L3

6

3

power supply 2

-X0

3

/90.2

GNYE

3

1

-BCC_1000

2

2

2

2

2

1

1

2

2L1

PE

-X0

-2PE

power supply 1

2L2

-1PE

D

1L1

E

-1K3 main switch

6

Hauptschalter

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-1K6

all lines without indication of cross section are

D

A

/2.1

1 A

1 A

main switch

1

-1F6

3

1

-1F3

2

6

4

B

C

/2.1

6 2

3

1

-1K6

5

1

-1K3

2

L3

3

A

/2.1

Einspeisung

440V / 60Hz

440V / 60Hz

24 KW~50 A

24 KW~50 A

max fuse: 63A

max fuse: 63A

PE

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 1

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 1

0-8100-100454-14-3

power supply / Einspeisung 5

=BCC

6

7

75 8

sh.

1

6

A

/3.1

43

33

21

13

5

/3.1

B 34

44

/30.2

/102.6

22

14 5 6

6

3 4

2 1

/30.4

2

-30K2

4

I>>I>>I>>

combustion air fan

/29.2

44

34 /30.6

22

14 /29.3

pump

6

I>>I>>I>> 4

44 /102.6

ignition oil

2

34 /30.4

22

14 /29.2

6

0.63...1A

5

2

3

1

-30K4

4

I>>I>>I>>

rotary cup atomizer

-2T5

2,5mm²

1

3

5

2

4

6

k

K

l

L

C

2

PE

1

2,5mm²

2,5mm²

6

4

2

/30.2

-30K6

-X10

combustion air fan

4 mm² 11

12

4 mm²

GNYE PE

660 PE

2

658 W

3

656

W

654

V

V

-X0 20/5A

-BCC_1003

M4G1,5

U

10

A

1

3

combustion air fan

GNYE

PE

U

8

7

6

5

2

-BCC_1005

M4G2,5

1

4

3 3

-X0

GNYE

2

1

2

-BCC_1004

1

-X0

PE

4 mm²

-2P5 +CC_D

9

/30.6

H07Z-K 1,5mm²

PE

D

M4G4

all lines without indication of cross section are

-X8

PE

W

V

+BW

U

protection note according to ISO 16016 consider!

/3.1

16...20A

2.5...4A

E

1

-2Q5

3

43

33

21

13

5

1

43

1

-2Q3

3

L3

33

L3

B

D

8

L2

-2Q2

C

7

L1

21

/1.8

5

L2

13

A

4

L1

5

/1.8

3

3

/1.8

2

E

M

M

M

3~

3~

3~

-2M2

-2M3

-2M5

+BN

+F 0,68A

+BN 16,7A

2,6A 1,32 KW

0,22kW

8,6KW

ignition oil pump

combustion air fan

BN 001 rotary cup atomizer

BN 001

BN 020

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 2

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 2

0-8100-100454-14-3

burner oil pumps 5

=BCC

6

7

75 8

sh.

43

21 22

/4.1

33

13 14

5

1

3

43

33

21

13

5

A

44 /104.3

/23.2

6

3

5

4

6

2,5mm²

4

2 1 2

2,5mm²

44

2,5mm²

34 /24.2

/104.3

6

22

14 4

2,5mm²

/23.1

-25K2

B

6

4

2

/25.2

6

4

I>>I>>I>>

MGOpump 2

5

3

2 1

2,5mm²

44

2,5mm²

34 /18.2

6 2,5mm²

/101.6

4 2,5mm²

22

/16.2

-24K2

5

2

I>>I>>I>>

MGO pump 1

/24.2 2

6

4

/4.1

R. modification

1

3

GNYE

W

PE

39

37

38

36

2

3~

3~

3~

-3M2

-3M3

-3M5

-3M7

+FOP1

+FOP2

+MGOP1

+MGOP2

0,72A

0,72A

0,8A

0,8A

0,25KW

0,25KW

0,3KW

0,3KW

fuel oil pump 2

MGO pump 1

drawn

ROS

check

ROS

name standard

U

M

3~

2012-01-30

date

1

GNYE PE

M

date

ROS

V

35

34

33 2

3 W

V

U

PE

W

V

M4G1,5

FO 001

30.01.2012

-BCC_1009

2

E

GO 001

replaced for

3

MGO pump 2

circuit diagram / Stromlaufplan 3

Control Cabinet Boiler origin

D

PE

-X0

M

fuel oil pump 1

as built

PE

M4G1,5

U

PE

W

V

U

32

-BCC_1008

M4G1,5

M

-X0

1

20 GNYE

3

2

1

GNYE

3

2

-BCC_1011

M4G1,5

all lines without indication of cross section are

PE

-X0

1

H07Z-K 1,5mm²

-BCC_1010

19

PE

-X0

18

17

16

15

14

13

C

F

0

-3Q7

/4.1

0.63...1A

/18.2 2

3

1

43

33

21

13

5

3

14

/17.2

3

-18K2

2,5mm²

44 /101.6

I>>I>>I>>

1

34

6 2,5mm²

/17.2

4

-3Q5 0.63...1A

fuel oil pump 2

5

2

2,5mm² 3

1

2,5mm²

I>>I>>I>>

-17K2

22

/16.2

14

0.63...1A

fuel oil pump 1

protection note according to ISO 16016 consider!

-3Q3

1

43

33

1

21

L3

B

E

8

L3

0.63...1A

D

7

L2

-3Q2

C

6

L1

13

/2.8

5

L1

5

/2.8

A

4

L2

3

/2.8

3

34

2

/25.2

1

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 3

0-8100-100454-14-3

fuel oil pumps 5

F =BCC

6

7

75 8

sh.

1

/3.8 /3.8

A

/3.8

2

3

4

L1

L1

L2

L2

L3

L3

5

6

7

8

/5.1 /5.1

+BCCFWP2 A

/5.1

AT

5

3

1

-Q2

A

43

33

21

13

5

1

3

0,16-0,25A

-4Q2

6

4

2

33

21

13

5

1

2

4

1

3

22 /21.5

34

14 /21.5

2

-F1

/21.6

2,5mm²

2,5mm²

2,5mm²

1

3

5

0,5 A

-K1

4mm²

control

-T1

115V C

6

4

/21.7 2

4mm²

4mm²

6

I>>I>>I>>

pump 2

4

feed water

6

4

3

44

34 /20.2

/103.3

22

14 /19.2

6 2,5mm²

4...6.3 A

5

3

2,5mm²

1 2

/21.2

B

0V

440V

0V

115V

0V

-1PE

-1L3

-1L2

PE

PE

3

GNYE

W

PE

4

2

3

1

2

D

1

24 GNYE

2

-BCC_1006

1

-X0

-X0

PE

V

23

22

3

21

-1L1

STU 63/2x115

-X0

PE

1

2

3

GNYE

1L2

1L3

1PE

-BCC_1002

1L1

M4G2,5

-BCC_1007 M4G2,5

U

PE

W

V

M4G4 U

E

-Q1

/21.4 B

I>>I>>I>>

power supply

/20.2

all lines without indication of cross section are

D

-20K2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

2,5mm²

2

pump 1

4

I>>I>>I>>

feed water

C

/21.1

BT

4...6.3 A

B

/21.5

-X

M

E

M

+MSB2

3~

3~ power supply 2

-4M2

-4M3

Einspeisung 2

+FWP1

+FWP2

440V / 60Hz

6,1A

6,1 A

3,5KW~10A

3 KW

3 KW

max fuse: 16A FW 001 feed water pump 1

feed water pump 2

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 4

replaced for

3

replaced by

feed water pumps

4

5

F

0-8100-100454-14 /3-32

=BCC +CC_M sheet 4

0-8100-100454-14-3 6

7

75 8

sh.

1

/4.3 /4.3

A

/4.3

2

3

4

5

6

7

8

L1

L1

L2

L2

L3

L3

Abo

13

21

33

43

14

22

34

44

5

3

1

-5Q4

24

22

14

1

-5F2

12

N1

/7.1 A /7.1

/8.4 /7.5

12,5-16A

/29.5

6

4

21 /29.4

2

11 21

5

3

1

A28

/28.3

C

2

4

6

4mm²

4mm²

4mm²

28

29

30

-X1 -BCC_2022

M4G4

D

22

21

15 GNYE PE

1 mm2 14 3 05

1 mm2 13 2 02

1 mm2 12 1 01

31

PE

GNYE

3

-BCC_1012

M3G1,5

2

27

24

-X0 1

2

-BCC_2020

PE

GNYE

26

22

14

1 mm2

12 1 mm2 25

-X0

/28.3

/28.4

/27.2

M4G1,5

V

230V

PE

L3

L2

burner

L1

+BN electrical heater

E

relay

current 13A

M

0V

-5E3

U

E

11

-27K2

all lines without indication of cross section are

D

-28K4

1

C

I>>I>>I>>

electrical preheater

B

A27

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

dosing pump

/27.2

chemical

2

B

/28.4

1 A

controller

power 6 KW

PE

1~ -5M2 +FW 0,28A 0,09KW BN 001

FW 008 F

F

chemical dosing pump

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 5

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 5

0-8100-100454-14-3

electrical heater/ chemical dosing pump 5

=BCC

6

7

75 8

sh.

1

2

/5.8 /5.8

3

4

5

6

7

8

L1 L3

A

A

/11.2

4

5

1

-7Q2

3

C

4...6.3 A

B 3

B

2 2

1

2 1

24V AC supply

-7F4

A1T1

-X11

/8.5

/9.7

4 A 230V AC supply

C

-7T2

/8.1

A1

L 115V

-20V

0V

460V

115V

A2

-7K5

power fault

0V

14

440V/230V 1600VA

11 D

/90.2 12 24

PE

control transformer

21

/100.5 22

6

5

/30.5

7

N1

8

/5.8

BbnT2

N

9

-X11

N2

10

E

A1

/9.7

1

6

2

protection note according to ISO 16016 consider!

4 A

all lines without indication of cross section are

D

-7F3

H07Z-K 1,5mm²

C

4

I>>I>>I>>

control voltage

A1T

N4

N_N N2_N N4_N

/8.5 E /9.7

/27.1

/77.2 /77.2 /42.6

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 7

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 7

0-8100-100454-14-3

230V supply 5

=BCC

6

7

75 8

sh.

2

/7.4

3

4

5

L

6

/7.8

A /7.8

7

A1

A1

8

/9.4

N

N

-8F6

A /9.4

1

1

B

2

2

1

power supply

boiler equipment

socket 230V 2

power supply

fan

2 A 2

2

power supply heating tracer

MGO pumps

B 5

burner equipment

-8F5

6 A

6 A

2 A power supply

-8F4

1

-8F3

1

-8F2

1

2 A

-8B6

E

4 44

C

53

54

-9K7

/9.6

/9.6

1

54

34

24

43

/9.6

33

34 23

-9K7

/9.6

/9.6

53

33

13 13

-9K7

-9K7

-9K6

/9.6

/9.6 14

/9.6

-9K6

6

θ

Thermostat /68.2

Amgo

-X111 /15.3

-8X8

fan

/12.1

N

+CC_D Abn

L

-8M6

/54.2

PE

L

D Ath

Abo

PE

Abo

/16.1 2

PE

3

/5.8

PE

N

cabinet

all lines without indication of cross section are

D

-9K6

14

C

-9K6

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

Abo1

-X111 PE

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 8

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 8

0-8100-100454-14-3

230V supply 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

/8.6

6

7

A1

A1

8

/10.2

-9K5

6

-X12

A1T1

/7.8

/7.8

A1T

61

14

4 24

4

62 1

-9K7

-9K5

13

-9K6

23

A 61

A

6 B

I2

/10.3

22

21

Reset Not-Stop

7

-10A3

DO

DO

/10.3

Q8

Q8

24

2

22

-X11

I4

C

41

33

23

13

S13

S10

A1

6

5

2

SR3C AC230V *

D

K2

ST K2

emergency stop 1

emergency stop 2

escape route

escape route

Not-Stop 1

Not-Stop 2

/8.8

-9K8

A2

A2

-9K7

A1

A1

42

-9K6

A2

/100.2

34

24 6

14

S14

S12

6

+F

S21

S11

A2

PE

NC

C

+F

/30.3

K1

-9S3

PE

NC

-9S2

I12

/10.3

K1

M2X1,5

*

-9K5

DI

N

N

emergency stop

emergency stop

/8.2

Fluchtweg

Fluchtweg

/102.7

option

option

/8.3

Yard Supply

Yard Supply

/8.5

If switche not used please make a connection

/8.4

between -X2.1+2 and -X2:3+4

4

13

14

23

24

33

34

43

44

53

54

61

62

73

74

83

84

/10.2

/7.8

emergency stop

/8.2 /8.3 /8.4 /29.7 /8.5 4

A1

M2X1,5

-X2 1

-BCC_3002

2

-BCC_3001

-X2 1

-X2

4

3

2

1

-10A3

C

protection note according to ISO 16016 consider!

E

reset emergency stop

-X12

all lines without indication of cross section are

D

-9K8

Kessel Stop

H07Z-K 1,5mm²

C

boiler stop

I11

Q4:2

/10.2

+CC_D +CC_D

Q4:1

-10A3

13

I3

-10A2

-9S8

DI 14

-9S1

DI

11

21

I2

62

B

N2

N2

reset emergency stop

13

14

14

23

24

/29.6 12

33

34

24

43

44

4 22

53

54

61

62

73

74

83

84

/12.1 E

11

21

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 9

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 9

0-8100-100454-14-3

emergency stop 5

=BCC

6

7

75 8

sh.

1

2

/9.7

A

3

4

A1

A1

1*)

/9.7

5

7

8

/13.1

A

2*)

N

N

-10R2

6

/11.1

-10R3

I3

I6

I8

LOGO 230 RCO

L1

N

I9

/9.7

/9.6

I4

I3

I2

N

I1

/30.3

I7

L1

/47.7 I8

/47.8

I5

I7

/35.6

I4

I6

I5

/32.8 I4

I3

I2

N

L1

I1

I2

SAACKE

I10 I11 I12

LOGO DM 8 230R

-10A2

-10A3

/61.2 Q2:2

/61.2

/9.8

Q4:2

1 Q8 2 Q4:1

Q3:2

Q3:1

1 Q7 2

/30.5

Q4:2

Q4:1 /30.5

Q3:2

1 Q4 2

/30.2

Q3:1

1 Q3 2

/30.2

/12.2

Q2:2

Q2:1

1 Q2 2

/12.2

Q1:2

1 Q1 2

1 Q6 2

/9.8

1 Q5 2

Q2:1

Q1:2

/32.3 Q1:1

/32.3

C Program: LOGO39

Q1:1

protection note according to ISO 16016 consider!

I1

D

all lines without indication of cross section are

D

N

H07Z-K 1,5mm²

C

L1

/32.7

B /9.5

B

E

E

1*

1*

2*

Brücken bei Umschaltung

Brücken bei Umschaltung

Gebläsenachlaufzeit von

Gebläsenachlaufzeit von

5

5

10 Minuten.

2*

to be linked, if fan

15 Minuten.

to be linked, if fan

after run time shell be

after run time shell be

changed from 5

changed from 5

10

minutes

15

minutes

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 10

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 10

0-8100-100454-14-3

control voltage 5

=BCC

6

7

75 8

sh.

1

2

N

N

4

aSC /12.6

5

6

7

A

aData

7

-X12

8

aT1

9

aT2

N

E

/13.7

/15.1

/92.1

I3.7

-11F5

1 A

24V

safety devices

4 A

1

5A

2

-11F4

24V DC supply

1

-11G2 230VAC/24VDC

24V DC

/90.1

service input

power supply

PE

aT1sch

2

PE

0V

C

PE

12

11

bData

13

-X12

14 15

protection note according to ISO 16016 consider!

230V AC

E.7

16

all lines without indication of cross section are

D

aT2sch

/60.2

B

/13.4

H07Z-K 1,5mm²

C

DI

A

C

L

/7.3

as

10

E.7

-13A1.1 B

8

/34.7 6

/10.4

3

bS

/13.1 D

bT2

bT1

bS2

bS4

bS_b bT2_b bT1_b bS2_b bS4_b

/13.7

/60.2

/46.7

/47.6

/73.1 E

/92.1 /90.1 /63.6 /70.4

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 11

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 11

0-8100-100454-14-3

24VDC supply 5

=BCC

6

7

75 8

sh.

1

2

4

8

13

12

40

39

38

36

37

35

/38.6

31 /36.4

/35.2

30 /36.5

34

29 /42.3

33

28 /43.2

/37.3

27 /42.5

32

26 /42.2

25

/35.3

11

10

9

8

7

6

X2 24

X4

23 /42.4

5 22

/36.5 21

/37.2

4 /43.3

/35.4

3 /36.2

20

19

18

17

16

/41.2

X1 15

/35.2

B

/36.5

/36.2

/35.4

DO

C

A1

D

H07Z-K 1,5mm²

-12K2

/11.3

N

N

/13.1

all lines without indication of cross section are

A2

protection note according to ISO 16016 consider!

/36.4

Q2

14

/10.2

Q2

X3

DO

Q2:2

-10A2

/41.4

F-OSA

Q2:1

B

E

7

A

SAACKE,

D

6

/30.2

2

Abn

-12A3

C

5

Abn

1

/8.3

A

3

/9.8

N2

N2

/16.1

fault F-OSA

14

E

11

/29.8 12 24

21

22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 12

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 12

0-8100-100454-14-3

firing sequence control 5

=BCC

6

7

75 8

sh.

1

2

/11.7

A

/10.4 /12.7

3

4

5

6

7

8

bS

bS

A1

A1

N

/11.7 PE

Eingang

Ausgang

Sensoren

16 x Eingang

/17.1

aT2 bT2

bT2

/92.1

4M

CPU

Output byte 0 - 1

3M

DC 15-30V

2M

/11.7 1M

PE

DC 24V

3L

DC 24V/AC 24-230V

2L

DC 24V

1L

M

L+

2M

AC 100-230V

N

PE

1M

PE L1

A

/15.1

N

B

/14.1

Input byte 2

B

/16.2

A.1

/18.2

E.2

/16.2

A.2

/20.2

E.3

/16.3

A.3

/22.2

E.4

/16.4

A.4

/17.8

E.5

/16.6

A.5

/18.8

E.6

/19.2

A.6

/27.4

E.7

/19.2

A.7

/27.6

E.0

/19.3

A.0

/27.3

E.1

/19.4

A.1

/27.7

E.2

/19.6

E.3

/36.7

E.4

/43.6

E.5

/29.6 analo input

S7-200 6ES7 214-2BD23-0XB0

-13A1

Port 1

E.1

/29.2

E.2

/29.3

E.3

/29.4

E.4

/29.5

E.5

/34.8

E.6

/56.8

E.7

/57.8

E.0

/73.4

E.1

/73.5

E.2

/76.8

E.3

/55.7

E.4

/42.8

E.5

/63.7

SIEMENS

E.6

/63.8

S7-200

E.7

1

Input byte 0 - 1

Port 0

M

E

V

M

2

/11.5

A+

C

Input byte 3

6ES7- 221-1BH22-0XA0

-13A1.1

B+

-13A5

Modbus interface

PE

1

Port 0

2

D

SIEMENS

TP177 micro

PE

Pin 3+8 Adr:1 Baudr:9600 Parity:0

Segment: Teilnehmernummer: 6AV6640-0CA11-0AX1

A+

/73.6 Bus-Out

M

E

/73.6

Bus-In

E

/29.2

EB2

E.1

E.0

EB3

/17.2

EB0

A.0

all lines without indication of cross section are

D

SIEMENS

/29.7

EB1

C

E.0

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

CPU 224XP

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 13

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 13

0-8100-100454-14-3

PLC S7 200 5

=BCC

6

7

75 8

sh.

1

2

/13.8

3

4

5

6

7

8

bS

bS

/15.1

A

A

PE

Input byte 6

/35.7

E.0

/23.6

E.1

/52.7

E.1

/29.8

E.2

/53.8

E.2

/23.1

E.3

/69.7

E.3

/23.2

E.4

/70.8

E.4

/23.3

E.5

/50.8

E.5

/23.4

E.6

/51.7

E.6

/23.7

E.7

/49.8

E.7

/59.8

E.0

/48.7

E.0

/20.8

E.1

/46.7

E.1

/22.4

E.2

/45.7

E.2

/17.3

E.3

/44.7

E.3

/18.3

E.4

/42.7

E.4

/24.3

E.5

/25.3

SIEMENS

E.6

/37.7

S7-200

E.7

/43.7

E.5

/41.6

SIEMENS

E.6

/77.8

S7-200

E.7

/43.5

EB4

E.0

Input byte 5

6ES7 221-1BH22-0XA0

C

EB7

16 x Eingang

EB5

protection note according to ISO 16016 consider!

16 x Eingang

B

Input byte 7

6ES7 221-1BH22-0XA0

D

-14A1

-14A1.1

all lines without indication of cross section are

D

DC 15-30V

H07Z-K 1,5mm²

C

DC 15-30V

EB6

Input byte 4

B

4M

3M

2M

1M

PE

4M

3M

2M

PE

1M

PE

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 14

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 14

0-8100-100454-14-3

PLC S7-200 5

=BCC

6

7

75 8

sh.

1

/13.4

A /11.7

/14.8

2

3

A1

4

/8.5

Amgo

5

Amgo

6

7

8

/23.1

A

as

as

bS

bS

PE

/16.1

/44.4

PE

PE

2L

1L

L+

M

PE

2L

1L

L+

DC 24V/AC 24-230V

8 x Relay Output

8 x Relay Output AB 2 A.0

AB 3

/27.8

A.1 A.2

A.0

/24.2

A.1

/25.2

A.2

/24.8

A.3

/27.5

A.3

/25.8

A.4

/74.7

A.4

A.5

/74.7

SIEMENS

A.6

/20.3

SIEMENS

A.6

S7-200

A.7

/22.2

S7-200

A.7

C

A.5

6ES7 222-1HF22-0XA0

6ES7 222-1HF22-0XA0

-15A1

D

-15A1.1

all lines without indication of cross section are

D

DC 24V/AC 24-230V

H07Z-K 1,5mm²

C

M

B

protection note according to ISO 16016 consider!

B

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 15

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 15

0-8100-100454-14-3

PLC S7-200 5

=BCC

6

7

75 8

sh.

1

2

/8.4 /15.8

4

5

6

7

8

Abo

Abo

as

as

/17.1 /17.2

A

23

A

3

-X1

M2X1,5

13

/3.4 12

-X11

17

14

+FO 006 FSL

press.switch

-X12

B

13

-16F7

14

/3.2

FOP

14

-3Q3

13

-3Q2

1

-BCC_3014

-X1

7

+CC_D

5

3 = Man P2

2 4 6 8 3

A0 M

1

7

5

3

1

+CC_D mode

mode

Betriebsart

Betriebsart

-X11

11

7

FO-PP2 FO-PP1

12

-X12

14

-X11

-16K7

14

-X12

19

13

18

C

/18.1

/17.1

/13.2

DI

DI

/13.2

E.1

-13A1 /13.2

E.2

E.4

E.3

E.2

-13A1

DI

-13A1 /13.2

E.3

-13A1

DI

DI

/13.2

E.4

E.5

Overload F.O.PP 1

Overload F.O.PP 2

AUTO F.O.PP 1

AUTO F.O.PP 2

press switch

I 0.1

I 0.2

I 0.3

I 0.4

F.O.PP

A1

-13A1

E.5

D

E.1

-16K7

I 0.5

/12.3

E

A2

protection note according to ISO 16016 consider!

E

-16S4

2 = OFF

3 = Man P1

all lines without indication of cross section are

D

1 = Auto P2

2 = OFF

H07Z-K 1,5mm²

C

A0 M

2 4 6 8

24

M2X1,5

-16S3 1 = Auto P1

2

-BCC_3014

B

N2

N2

/17.7

press. switch FOP

14

11

6 12 24

FO 006

21

22 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 16

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 16

0-8100-100454-14-3

FOP control 5

=BCC

6

7

75 8

sh.

1

2

/16.8

3

4

5

6

7

8

Abo

Abo

/18.1

FOP1 STBY

A

FOP1

O0.0

/16.8

as

as

fault

/18.2

A

O0.4

-13A1

-13A1 21

-17K7

A.0

/13.2

A.4

/13.2

7

A.4

22

DO

E.2

A.0

24

DO

-14A1.1 B

/14.4 /16.4

FO-PP1

DI B

E.2

-17K2

E

5

GNYE 6

5

6

5

4 2

3 3 1

4

24 2 2 3

1 1

-BCC_2120

7

PE C

11

M7G1,5

33

-3Q2

4

-X20

12

14

-17K7

+FOP1

-X1

X1

PE

-H1 X2

21 22

local / remote

13

22

-S1

14

off

21

on

-S2

14

-S3

13

34

/3.2

GN D

operation

-17K8 A2

/16.8 /13.8

N

N oil pump 1

/18.1

N2

N2 local / remote

14

/3.2 /3.2 /101.4 4 /90.3 /28.4

1

2

24

3

4

3 22

5

6

13

14

23

24

33

34

43

44

21

/18.7

FOP1 Standby fault

11

2 12 /3.2

A1

-17K7

A2

-17K2

A1

A1

Drawing no: 0-xxxx-xxxxx /3-32

all lines without indication of cross section are

D

2

A2

C

I 7.2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

FOP1

23

local /remote

14

11

E

/101.7 12 24

21

22

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 17

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 17

0-8100-100454-14-3

fuel oil pump 1 5

=BCC

6

7

75 8

sh.

1

/17.8

2

3

4

5

6

7

8

Abo

Abo FOP2 STBY

A FOP2

O0.1

/17.3

as

as

fault

/19.1

/19.1 A

O0.5

-13A1

-13A1 21

-18K7

A.1

/13.2

A.5

/13.2

7

A.5

22

DO

E.3

A.1

24

DO

-14A1.1 B

/14.4 /16.5

FO-PP2

DI B

E.3

-18K2

E

5

GNYE 6

5

6

5

4 2

3 3 1

4

24 2 2 3

1 1

-BCC_2121

7

PE C

11

M7G1,5

33

-3Q3

4

-X21

12

14

-18K7

-X1

+FOP2 34

/3.4

X1

21

X2

-H1

22

local / remote

13

22

-S1

14

off

21

-S2

14

on

13

PE

-S3

GN D

operation

A2

/17.8 /17.7

-18K8

N

N oil pump 2

/20.1

N2

N2 local / remote

14

11

2 12 /3.4 /3.4 /3.4 /101.5 4 /90.3 /28.4

1

2

24

3

4

3 22

5

6

13

14

23

24

33

34

43

44

A1

-18K7

A2

-18K2

A1

A1

Drawing no: 0-xxxx-xxxxx /3-32

all lines without indication of cross section are

D

2

A2

C

I 7.3

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

FOP2

23

local / remote

21

/19.1

FOP1 Standby fault

14

E

11

/101.8 12 24

21

22

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 18

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 18

0-8100-100454-14-3

fuel oil pump 2 5

=BCC

6

7

75 8

sh.

1

4

5

6

7

8

Abo

Abo as 25

15

as

-X11

-X1

20

-X1

FSL

switch

14

14

press.

-X12

A

M2X1,5

+FW005 12

/22.8 14

/4.2

-19F7

/20.7

13

-22K8

11

-4Q2

13

-BCC_3016

/20.1

27

/18.3

A

3

1

/18.8

2

FWP

B

E

DI

/13.2

-13A1 /13.2

11

7

D E.2

DI

-13A1 /13.2

E.1

E.7

E.0

Overload F.W.PP 2

AUTO F.W.PP 1

AUTO F.W.PP 2

I0.7

I 1.0

I 1.1

I0.6

/22.1

14

-X12

-19K7

12

22

/20.1

FW-PP2

E.1

FW-PP1

DI

E.2

press switch F.W.PP1

-19K7

A2

I 1.2

A1

Overload F.W.PP 1

/13.2

28

17

16 21

E.6

-13A1

DI

C

-X11

E.0

E.7

E.6

/13.2

-13A1

-X1

Betriebsart

-X12

DI

-X1

mode

-X11

-13A1

M2X1,5 26

+CC_D

5

3 = Man P2

2 4 6 8 7

7

5

3

1

+CC_D

Betriebsart

all lines without indication of cross section are

D

A0 M

mode

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

3 = Man P1

-BCC_3016

-19S4

2 = OFF

2 = OFF

C

1 = Auto P2

3

A0 M

1 = Auto P1

2 4 6 8

1

-19S3

2

B

/18.8

N2

N2

E

/20.2

press.switch FWP

14

11

6 12 FW 005

24

21

22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 19

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 19

0-8100-100454-14-3

FWP control 5

=BCC

6

7

75 8

sh.

1

/19.8

2

3

4

5

6

7

8

Abo

Abo

/27.1

A

A FWP1 STBY

as

-15A1

-20K7

A.6

/15.1

DO

E.0

A.6

A.2

DO

FW-PP1

-14A1.1

B

12

14 2

3

4

5

2

3

4

5

-BCC_2220

GNYE 6

1 1

11

I 7.0 PE

M7G1,5

6

5

-H1 X2

22

local / remote

14

off

21

on

14

34

/4.2

PE

X1

2 21

1

-S1

13

-S2

22

-S3

13

-4Q2

-X1

33

+FWP1

3

4

C

GN

operation Drawing no: 0-xxxx-xxxxx /3-32

-20K3

/18.6

A2

/19.8

N

N2

N2 N FWP1 Standby fault

14 feed water pump 1

1

2

3

4

5

6

13

14

23

24

33

34

43

44

/4.2 /4.2 /4.2 5 /27.2 /90.4 /103.2

A1

-20K7

A2

-20K2

A1

A1

D

A2

protection note according to ISO 16016 consider!

E

FWP1

-X30

all lines without indication of cross section are

D

B

E.0

local remote

2

7

H07Z-K 1,5mm²

C

14

-20K2

DI

13

/14.4

-20K7

/22.3

7 24

A.2

/13.2

/19.4

as

22

-13A1

/19.8

fault O2.6

21

FWP 1 O 0.2

11

11

2 12

/103.4 12 24

/22.1

local / remote

/24.1 14

24 21

21 E

8 22

22

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 20

replaced for

3

replaced by

feed water pump 1

4

5

0-8100-100454-14 /3-32

=BCC +CC_M sheet 20

0-8100-100454-14-3 6

7

75 8

sh.

1

2

3

4

5

6

7

8

Drawing no: 0-xxxx-xxxxx /3-32

P_INO

/22.5

+FWP2 A

P_Stop

6

5

3

4

2

1

pump 2

FWP_Bbo

/22.5

/22.5

14

/22.2

PE

-X1

11

-22K2

remote

GNYE 7 12

6 6 11

5

4

3

2

3

4

7

8

9

5

1

-BCC_2222

-X31

6

-X31

GNYE

5

2

1

4

3

2

1

on

B

-BCC_2221

A /22.5

13

21

-S

12

pump on

14

local

-S

14

GN

22

X1

-H1

22

-S1

13

21

X2

P_Flt

B

M7G1,5

E

10

13

5

2

1

4

3

C

14

12

2 11

13 14

local / remote

21

-S1

22

21

-Q1

22

-K2

/4.6

AT /4.7

/4.8

B

overload

A1

-K1 X2

BT

RD

D

GN

A2

/4.8

-H1 X2

-H2

A1

-K2

X1

X1

34

/4.8

-Q1

33

A

14

34

/4.6

24

2 22

7

14

/4.8

-Q1

13

-K1

7

21

-K2

PE 33

13

-K1

all lines without indication of cross section are

D

-X1

A2

C

+BCCFWP2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

M7G1,5

operation

local stop

14

feed water pump 2

11

E

7 12 24

/4.6

21

/4.6

7 22

/4.6 3

4

1

2

3

4

5

6

13

14

21

22

33

34

43

44

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 21

replaced for

3

replaced by

feed water pump 2

4

5

0-8100-100454-14 /3-32

=BCC +CC_M sheet 21

0-8100-100454-14-3 6

7

75 8

sh.

1

2

3

4

5

6

7

8

Wiring color = orange A

FWP2STBY fault

FWP 2 O0.3

/21.8

A.3

/13.2

A

O2.7

-15A1

-13A1

P_INO

/21.8

P_Flt

A.7

/15.1

DO

/20.8

A.3

A.7

DO

as

as

/23.1

/21.8

/21.8

P_Stop

FWP_Bbo

B

B /19.5

FW-PP2

21 22

24 E.1

E.1

14

12

6 local stop FWP2 I 7.1

/20.8

N2

local stop FWP2 Standbyfault

all lines without indication of cross section are

11

14

/21.6 12

14

11

24

22

11

24

21

A1

A1

feed water pump 2 overload

11

14

/27.3 12 21

24

4 22

22

feed water pump 2 in operation

14

2 12

/103.5 12 21

-22K8

/23.1

feed water

24

-22K7

A2

A2

N2

14

A1

-22K6

A2

-22K3

A2

-22K2

A1

D

pump 2 on

E

C

DI

/14.4

11

-22K6

A1

D

-14A1.1

A2

C

6

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-22K6

21

24

/90.5 22 34

11

/19.2 12 21 E

/103.3 22 31

/103.2 32 44

41

42

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 22

replaced for

3

replaced by

feed water pump 2

4

5

0-8100-100454-14 /3-32

=BCC +CC_M sheet 22

0-8100-100454-14-3 6

7

75 8

sh.

1

/15.4 /22.5

3

4

5

6

7

8

Amgo

Amgo

as

as

/24.1 /24.2

A

41

A

2

-BCC_3018 M2X1,5

/3.7 33

-X11

30

press.switch

FSL

MGO

14

14

+GO 006

-X12

B

13

-23F7

14

/3.5

-BCC_3018

-X1

7

+CC_D

5

3 = Man P2

2 4 6 8 3

A0 M

1

7

5

3

1

+CC_D mode

mode

Betriebsart

Betriebsart

31

/35.2

11 12

7 14

-X11

MGO-PP2 MGO-PP1

-23K7

34

-X12

32

-X11

35

-X12

-35K2

32

34

31

C

/25.1

/24.1

/22.3

DI

/14.4

E.2

-14A1.1 /14.4

E.3

Overload MGOP 1

Overload MGOP 2

I 6.2

I 6.3

DI

-14A1.1 /14.4

E.4

AUTO MGOP 1

-14A1.1

DI

/14.4

E.5

E.6

E.5

E.4

E.3

-14A1.1

-14A1.1

DI

/14.4

E.0

DI

E.6

AUTO MGOP 2

release

press switch

I 6.5

MGO .PP

MGOP

I 6.0

I 6.6

I 6.4

-23K7

A1

/14.4

DI

E

A2

-14A1.1

E.0

D

E.2

protection note according to ISO 16016 consider!

E

-23S4

2 = OFF

3 = Man P1

all lines without indication of cross section are

D

1 = Auto P2

2 = OFF

H07Z-K 1,5mm²

C

A0 M

2 4 6 8

42

M2X1,5

-23S3 1 = Auto P1

B

2

13

-3Q7

13

-3Q5

1

-X1

N2

N2

/24.7

press. switch MGO

14

11

7 12 GO 006

24

21

22 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 23

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 23

0-8100-100454-14-3

MGO control 5

=BCC

6

7

75 8

sh.

1

2

/23.8

A

3

4

5

6

7

8

Amgo

Amgo

/25.1

MGOP1 STBY MGOP1

O3.0

/23.8

as

as

fault

/25.2

-15A1.1

A

O3.2

-15A1.1 A.0

/15.3

21

-24K7

A.2

/15.3

7

-14A1.1 /14.4

B

/23.4

A.2

22

DO

E.4

A.0

24

DO

DI

B

E.4

MGO-PP1 local remote

E

23

5

GNYE 6

5

6

5

4 2

3 3 1

4

24 2 2 3

1 1

-BCC_2122

PE

C

11

M7G1,5

33

-3Q5

4

12

14

-X40

7

+MGOP1 /3.5

-X1

X1

21

X2

-H1

22

local / remote

13

22

-S1

14

off

21

on

-S2

14

13

34

PE

-S3

GN

D

operation

A2

/23.8 /20.7

-24K8

N

N MGO pump 1

/25.1

N2

N2 local / remote

14

11

2 12 /3.5 /3.5 /3.5 /104.1 /90.6

1

2

24

3

4

3 22

5

6

13

14

23

24

33

34

43

44

A1

-24K7

A2

-24K2

A1

A1

Drawing no: 0-xxxx-xxxxx /3-32

all lines without indication of cross section are

D

-24K7

A2

C

-24K2

I 7.4

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

MGOP1

21

/25.7

FOP1 Standby fault

14

E

11

/104.4 12 24

21

22

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 24

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 24

0-8100-100454-14-3

MGO pump 1 5

=BCC

6

7

75 8

sh.

1

2

/24.8

3

4

5

6

7

8

Amgo

Amgo MGOP2 STBY

A MGOP2

O3.1

/24.3

as

as

fault

/29.1

-15A1.1

A

O3.3

-15A1.1 A.1

/15.3

21

-25K7

A.3

/15.3

7

-14A1.1 /14.4 B

/23.5

A.3

22

DO

E.5

A.1

24

DO

DI

E.5

B

MGO-PP2 local remote

-25K2

E

5

GNYE 6

5

6

5

4 2

3 3 1

4

24 2 2 3

1 1

-BCC_2123

PE C

11

M7G1,5

33

-3Q7

4

12

14

-X41

7

+MGOP2

-X1

21

X1

PE

X2

-H1

22

local / remote

13

22

-S1

14

off

21

on

-S2

14

-S3

13

34

/3.7

GN

D

operation

all lines without indication of cross section are

A2

/24.8 /24.6

-25K8

N

N MGO pump 2

/28.1

N2

N2 local / remote

14

11

2 12 /3.7 /3.7 /3.7 /104.2 4 /90.6

1

2

24

3

4

3 22

5

6

13

14

23

24

33

34

43

44

A1

-25K7

A2

-25K2

A1

Drawing no: 0-xxxx-xxxxx /3-32

A1

D

-25K7

A2

C

2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

I 7.5

23

MGOP2

21

/27.3

FOP2 Standby fault

14

E

11

/104.5 12 24

21

22

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 25

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 25

0-8100-100454-14-3

MGO pump 2 5

=BCC

6

7

75 8

sh.

1

2

/20.8

3

4

5

6

7

8

Abo

Abo

A

A common alarmcomb air

alarm

A.0

alarm

( ECR ) O0.6

( ECR )O2.0

-15A1 A.6

/13.2

-13A1 A.3

/15.1

A.7

/13.2

-15A1 A.1

/13.2

DO

A.3

A.0

-13A1

DO

DO A.6

DO

14

12

alarm ( ECR )O1.1

-13A1

/13.2

/5.2

alarm ( boiler cabinet ) O0.7

A.0

/15.1

DO

DO A.0

-13A1

11

-5F2

low (ECR ) O2.3

A.1

O1.0

shut down

flame failure

A.7

accoustic com alarm

common

B 18

B

E

1 2 19

C

-X11

11 14

/22.7 12

feed water

24

/20.2

pump 2

-22K7

23

pump 1

-20K2

/7.8

N4

N4

/35.1

/25.8

14

11

24

flame failure

alarm

(ECR)

24

/5.2 22 34

accoustic com

11

12

21

22

31

A1 A2

N2

14

/5.2 12

A1

N2

chemical dosing pump in operation

-27K8

A2

-27K7

A2

-27K6

A2

-27K5

A1

A1

A1

-27K4

A2

A2

-27K3

A2

-27K2

A1

A1

D

all lines without indication of cross section are

D

+CC_D

Chemikaliendosierpumpe

feed water

C

-27S2

chemical dosing pump

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-X11

14

11

24 22

14

11

/102.5 12

/102.4 12 21

alarm comb.air low ( ECR)

21

24

alarm ( cabinet)

14

11

21

22

24 22

common

alarm ( ECR )

shut down alarm ( cabinet)

14

11

/100.4 12

/92.7 12 21

/32.2

common

24

14

E

11

/100.4 12 21

22

24

21

22

/90.5 32 44

41

/101.5 42

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 27

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 27

0-8100-100454-14-3

dosing pump 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

-5Q4

/54.3

13

A54

/5.4

B

E

/5.6

43

43

C 44

fuel oil

pump 1

pump 2

/18.2 44

/5.5

A27

A28

A1

D

A2

-28K4

all lines without indication of cross section are

D

-18K2

/17.2

fuel oil

C

-17K2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

14

B

/25.6

N

N

/30.2

E electrical preheater

/5.4 /5.4 /5.4 /92.6

1

2

3

4

5

6

13

14

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 28

replaced for

3

replaced by

electrical preheater

4

5

0-8100-100454-14 /3-32

=BCC +CC_M sheet 28

0-8100-100454-14-3 6

7

75 8

sh.

1

6

7

8

43

B

/12.2 12

44

14

12

11

-12K2

/9.6

14

-9K7

/9.7 34

24

22

11

-9K8

/5.4

/5.2 14

33

-5Q4

21

-5F2

A

/55.2

/13.4

DI

-13A1.1 /13.4

E.0

-13A1.1

E.1

DI

/13.4

E.2

-13A1.1 /13.4

DI

-13A1.1 /13.4

E.3

DI

-13A1

DI

/13.2

E.4

E.0

E.5

E.4

E.3

E.2

DI

E.5

overload

overload combustion air

overload

overload chemical

overload

reset

rotary cup

fan

ignition oil

dosing pump

preheater

I 1.5

I 2.0

I2.1

pump

I2.3

I2.4

-13A1 /13.2

E.1

-13A1.1

E.1

E.0

C

DI

-14A1.1

DI

/14.4

E.0

voltage alive ( I 0.0)

E.1

fault F-OSA I 6.1

D

I2.2

all lines without indication of cross section are

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

/2.4 14

/2.6 14

B

-2Q3

13

-2Q5

/2.2

D

5

as

-2Q2

C

4

as

13

/25.3

3

13

A

2

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 29

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 29

0-8100-100454-14-3

common inputs 5

=BCC

6

7

75 8

sh.

1

2

/12.2 A

3

Abn

Abn

5

6

7

8

/31.1 A

14

-46K6

4

20

13

/46.6

2/4

-X11 -30S2

/9.7

ST

ST

/32.7

B

/48.6

-10A2

DO

/10.2

Q4

22

24

Q3:1

-10A2

I2

DI

Q4

/10.2

DO

I10

Q4:2

Q3

/10.3

ZP

C

/37.3

Q3

/10.2

-2Q3

34

33

-2Q5

33

-2Q2

33

Q3:2

DO

/2.2

/2.4 34

34

/2.6

36

D

-X11

+CC_D

A2

N

N

/2.6 /2.6 /2.6 /92.5

/101.3 /32.5

R. modification

1

1

2

3

4

5

6

13

14

21

22

33

34

43

drawn

ROS

check

ROS

date

name standard

/2.2 /92.4

/32.5

1

2

3

4

5

6

13

14

21

22

33

34

43

44

/2.4 /2.4 /2.4 /92.4

1

2

3

4

5

6

13

14

21

22

33

34

43

44 F

2012-01-30

ROS

/2.2

44

date

30.01.2012

/2.2

E

/33.4

ignition oil pump

rotary cup atomizer

combustion air fan

as built

-30K6

BbnT2

Drehzerstäuber

/28.8

/7.8

h

A1

-30K4

A2

A1

-30P5

A2

30K2

F

0

-10A3

-10A2

rotary cup atomizer

E

DO

/10.2

all lines without indication of cross section are

D

/32.6

A1

C

-10A2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-X11

-32K6

21

42

22

21

-48K6

Q4:1

combustion air fan

41

+CC_D

3

B

1

A0 M

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 30

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 30

0-8100-100454-14-3

burner motor control 5

=BCC

6

7

75 8

sh.

1

2

/30.2

3

Abn

Abn

4

5

6

7

8

/36.6

high

61

62

13

windbox

C 62

12

/34.6 ESS

/59.4

mode

H1

-34K6

/32.2

14

11

HFO /MDO

14

61

13 14 14

-34K6 -59K4

in

/34.6 13

ESS

13

mode

-50K6

D

/50.6 HFO_T_low

14

protection note according to ISO 16016 consider!

temp

F1

/34.6

all lines without indication of cross section are

D

MDO

/48.6

flue gas/53.6

/57.6

13

B

fire

H07Z-K 1,5mm²

C

-53K6

14

/52.6

press.

-48K6 -57K6

13

13

steam

14

24

-52K6

oil pressure /49.6

MGO

/59.7 14

B

-49K6

14

/56.6 62

HFO

-59K7

13

-56K6

23

A

61

A

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 31

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 31

0-8100-100454-14-3

safety interlock circuit 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

-30K2

comb.air fan

/30.2 44

H1

13

-69K5

LLW1

/69.5 14

-30K4

44

/31.7

43

A

rotary cup

/30.4 B

43

B

LLW2

E

14

33

12

comb.air

/45.4

33

ST

C

33

11 I4

14

/10.2

I3

/10.2

I4

/33.4

A2

-32K6

N2

N2 combustion air fan

14

DI

/34.3

A1

N1

/27.8

-10A2

D M1

-32K2

DI

A1

Ess-mode

/34.6

-10A2

34

DO

71

-34K6

Q1:2

Q5

Q5

72

23

/10.3

DO

I3

Q1:1

24

-10A3

ESS mode /34.6

6 12

2

-32K6

14

33

-32K2

12

/44.4

-34K6

/35.6

primary air 11

34

-44K4

ST

34

/30.4

SW burner

/46.6

all lines without indication of cross section are

D

-45K4

A2

C

-46K6

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

/70.4

34

11

-70K5

rotary cup atomizer

11

14

7 12

/35.5 E

11

8 12

24

21

24

22

21

/30.4 22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 32

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 32

0-8100-100454-14-3

safety interlock circuit 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

/32.5

N1

B

41

33

23

13

S13

S10

A1

-33K4

SR3C AC230V K1 K2 K2 K1

/30.8

42

/54.6

34

24

N

/42.2

14 /35.2

S14

S12

S21

S11

D

N

/34.3

safety interlock circuit

all lines without indication of cross section are

D

C

A2

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 33

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 33

0-8100-100454-14-3

safety interlock circuit 5

=BCC

6

7

75 8

sh.

2

3

4

5

6

7

-38K2

aSC

aSC

/35.7

A

14

/11.4 12

A

8

/38.2 11

-34K6

43

1

23

-13A1.1 23

23

ZV

/13.4

DI

E.5

/37.2 C

5

6

10

GNYE

4

N

1

3

2

/33.5

9

6

7

-BCC_2005

8

-X1

/31.5

F1

F1

/35.3

M16G1,5

14

14

24

A2

21

/61.6 22

Notbetriebskasten 19.00

21

-S4

13

X2

X1

-H1

ignition

oil valves

flame

Zündung

Ölventile

Flamme

/31.4 /32.2 /32.5 8

21

-S3

/54.5 /31.4 /32.5 *)

A1

N emergency operation

14 22

-S2

11

/61.6 12

13

-S1

22 14

emergency operation box

13

+BN

13

14

/37.2

-34K7

A2

A2

-34K6 BBW1

*)

A1

-16K1

/61.6 194

190

189

200

199

191

-X8

198

196

197

195

DEC

A1

/61.6

193

INC

16

PE

9

6

8

7

-X1.1

10

D +BW

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

/38.1

/40.3

emergency operation (I 2.5)

all lines without indication of cross section are

E

OV

B /39.2

E.5

-40K3

/39.3

D

24

FL

-39K3

C

13

M1 24

/32.5

24

B

7 14

/40.3 14

/39.3

-34K7

14

-40K3

13

-39K3

13

44

6

wire jumper has to be

13

14

23

24

33

34

43

44

53

54

61

62

71

72

81

82

emergency operation

5 5 /37.3 /42.6 /39.3 /40.3 /42.6 /38.6

13

14

23

24

33

34

43

44

51

52

61

62

71

72

81

82

/35.2 E

arranged during commissioning

19.00 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 34

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 34

0-8100-100454-14-3

emergency operation 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

common safety interlock circuit

-12A3

X3:16

0VAC

X4:35

controlled shut-down

X2:12

X3:18

X3:21

-33K4

13

/12.3

14

/33.4

E

14

12

/47.7

11

-35K2 2 22

11

2 14

14

ST

-35K2

/63.3

-X11

ST

12

26

2- emergency operation / Notbetrieb

27

0- off / Aus

F1 E.0

I5

-35K6

/34.7 /27.2

N4

N4 burner start

14

N

/42.2

/32.6

-14A1

/10.2

I5

/14.1

DI

E.0

burner start

burner start ( I4.0)

N2

N2 burner

/36.1 E

stand by

11

14

11

/92.2 12 21

24

7 22 34

DI

/39.3

6 12 24

-10A2

A2

N

D

A1

A1

-35K2

/36.7

21

/32.8

-63K3

1- automatic / Automatik

aSC

C

1

3

Brenner Betriebsart +CC_D

aSC

24

12

fault

/34.8

1 0 2

burner mode

/34.7

11

25

/43.2

2/4

-35S5

all lines without indication of cross section are

D

-43K2 burner

A2

C

B

-X11

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

21

/100.3 22 31

/23.6 32 44

41

42

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 35

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 35

0-8100-100454-14-3

burner start 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

A

7

Abn

/31.3

purge position

-12A3

X4:24

ignition position

X1:3

X4:31

Abn

8

A

/39.3

reset

X3:15

X4:30

X4:40

X1:5

/12.3

11 14

11 14

12

C

24

E.3

+CC_D reset burner

13

-36S5

2

14

61

-X11

-13A1

-X11

/13.2

DI

E.3

purge position ( I 1.3)

-36K7

/35.8

A2

-36K3

A1

D

N2

N2

all lines without indication of cross section are

purge position

E

B

-36K3

23

21

11

62

14 13

/47.5

A1

D

purge position

/37.6

6

A2

C

-47K5

/47.5

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-47K5

aSC

22

-36K7

6

24

12

14

12

24

-36K7

aSC

/35.7

/42.5 22

ignit.position

14

12

B

-42K5

/47.6

12

/47.6

21

-47K6

11

11

-47K6

14

11

14

7 12 24

/37.7

reset

11

4 12 21

24

22

21

E

5 22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 36

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 36

0-8100-100454-14-3

burner reset 5

=BCC

6

7

75 8

sh.

2

3

4

5

6

A

/36.8

ignition transformer

-12A3

7

8

aSC

aSC

/41.6

A

general ignition valves

X3:22

X4:34

-37K7

/12.3

11

1

/30.7

ZP B

E.6

B

14

12

7

33 34

ignition ( I 7.6)

ZV

8

C

-BCC_2005

1

-BCC_2005

-X1

M16G1,5

2

-X1

M16G1,5

13

12

11

10

9

-X8

+BN

+BN

+BN

-37K7 /38.6

/36.8

PE

2

-2Y3 1

PE

2

-2Y2 1

PE

2

-2Y1 1

-2T1

BBW1

A1

8

7

-X8

BBW1

PE

/34.6

-X8

A2

-X8

6

5

4

2

-X1.1

3

-X1.1

+BW

2

1

D

A2

E

E.6

7

/34.2

all lines without indication of cross section are

D

DI

/34.7

A1

C

/14.4

-34K7

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-14A1.1

+BN

N2

N2 ignition

14

/38.1 E

11

7 12 24

21

/54.6 22 ignition transformer

ignition oil valve 1

ignition oil valve 2

ignition oil relief valve

Zündtrafo

Zündölventil 1

Zündölventil 2

Zündölentlastungsventil

13.01

13.03

13.09

13.11

13.01

13.03

13.09

13.11

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 37

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 37

0-8100-100454-14-3

ignition system 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

oil valves

-12A3

X4:36

/12.3

82

-BCC_2005

3

-X1

M16G1,5

-X8

Gleichrichter

21

31

30

29

PE

2

E

+BN A4

+BN

/61.7

V

U

1

PE

2

1

-3Y5

rectifier

A3

+BN

BBW1

-3A1

-3Y2

A2

11

/34.4 12 24

-3Y1

-X8

BBW1

L+

L-

14

/41.5

PE

N2 oil valves

2

N2

16

-X8 /37.6

1

/37.7

15

14

22

21

20

19

18

17

A1

-X8

A2

-38K2

3

D

-X1.1

+BW

A1

E

C

OV

9

/34.5

all lines without indication of cross section are

D

/34.7

H07Z-K 1,5mm²

C

-34K7

81

B

protection note according to ISO 16016 consider!

B

/54.6 22 main oil valve 1

main oil valve 2

main oil relief valve

Hauptölventil 1

Hauptölventil 2

Hauptölentlastungsventil

06.01.01

06.01.02

06.10

06.01.01

06.01.02

06.10

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 38

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 38

0-8100-100454-14-3

oil valves 5

=BCC

6

7

75 8

sh.

1

2

FL

4

Abn

/36.7

5

Abn

6

7

8

/40.3

28

/34.5

3

A

A

-34K7

2/4

-39S2

/34.7

1 2

52

3 30

emergency operation

1

+CC_D

29

selection flame scanner

51

-X11

-X11 FL2

/40.3

9

10

7-

8+

15

B 11

B

6

1

2

3

4

5

13

14

5

4

3

2

1

6

5

4

3

2

1

S

C

-X3

-BCC_4001 M5X0,75SH

5

4

3

2

1

6

502

503

504

505

506

-39K3

-X3.1

A1

+BW

501

D

-X8

/34.4 /41.4 /41.4

-40B1

13

14

23

24

33

34

43

44

53

54

61

62

flame scanner 1

71

72

Flammenfühler 1

83

84

+BN

E YE

/34.4

/40.3

WH

N flame signal 1

GN

N

RD

/35.3

BU

E

12

PE

all lines without indication of cross section are

D

flame detector 1 Flammenwächter 1

A2

C

Saacke, FLUS 06 UV

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-39A3

Die Verlegung der Fühlerleitung muß räumlich getrennt von Netz- und

Saacke FLS 09 UV

Steuerleitungen sowie energiereichen Starkstromleitungen bzw.- einrichtungen (z.B. Zündleitungen, Zündtrafos, Elektromotoren, Schütze) erfolgen. Eine parallele Leitungsführung zu Netzleitungen in Kabelkanälen ist nicht zulässig.

The installing of the probe line must be separate from the supply and control mains as well as from the power lines and high voltage systems (e.g. ignition lines, ignition transformers, electric motors, contactors). A parallel line arrangement to the supply lines in the

14.02

cable ducts is not admissible.

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 39

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 39

0-8100-100454-14-3

flame detection 1 5

=BCC

6

7

75 8

sh.

1

2

3

4

Abn

/39.4

5

Abn

6

7

8

/42.6 A

-34K7

61

A

62

/34.7

/39.2

FL2

9

10

7-

8+

15

B 11

B

6

1

2

3

4

5

13

14

11

10

9

8

7

12

5

4

3

2

1

S

C

-X3

-BCC_4002 M5X0,75SH

5

4

3

2

1

6

508

509

510

511

512

-40K3

-X3.2

A1

+BW

507

D

-X8

/34.4 /41.4 /41.4

-40B2

13

14

23

24

33

34

43

44

53

54

61

62

flame scanner 2

71

72

Flammenfühler 2

83

84

+BN

E YE

/34.4

/54.7

WH

N flame signal 2

GN

N

RD

/39.4

BU

E

12

PE

all lines without indication of cross section are

D

flame detector 2 Flammenwächter 2

A2

C

Saacke, FLUS 06 UV

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-40A3

Die Verlegung der Fühlerleitung muß räumlich getrennt von Netz- und

Saacke FLS 09 UV

Steuerleitungen sowie energiereichen Starkstromleitungen bzw.- einrichtungen (z.B. Zündleitungen, Zündtrafos, Elektromotoren, Schütze) erfolgen. Eine parallele Leitungsführung zu Netzleitungen in Kabelkanälen ist nicht zulässig.

The installing of the probe line must be separate from the supply and control mains as well as from the power lines and high voltage systems (e.g. ignition lines, ignition transformers, electric motors, contactors). A parallel line arrangement to the supply lines in the

14.02

cable ducts is not admissible.

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 40

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 40

0-8100-100454-14-3

flame detection 2 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A /37.8

aSC

aSC

/42.7

flame signal

-12A3

X3:20

X3:14

/12.3

B

B 11

-41K5

E

14

43

33

C

43

44

34 34

-39K3

33

44

E.5

/39.3

/47.5

/14.1

E.5

reached

D

33

24

22

purge

purge pos.

/42.2 14

/42.2

-47K5

DI

flame signal ( I5.5)

A2

-41K5

A1

-42K2

21

11

-42K2

34

-14A1

all lines without indication of cross section are

D

/40.3

12

C

-40K3

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

12

5

/38.2

N2

N2 ignition

14

/42.2

11 E

6 12 24

21

22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 41

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 41

0-8100-100454-14-3

flame detection 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

/40.4

Abn

7

Abn

8

/61.4

A

A

-12A3

purge

end of purge

release monitoring flame

burner fires

X4:26

X4:29

X3:23

X4:27

aSC

/41.7

aSC

/43.5

/12.3

34

32

14

12 43

71

E.4

E.4

44

72

34

-13A1.1

DI

/13.4

E.4

DI

E.4

C

31

/14.1

-X11

release

purge ( I 3.4)

-42S6

1

+CC_D

2

flame signal ( I 5.4)

release

32

load control

/35.2

/41.5

/7.8

N2

N2 purge

14

11

/41.2 12 24

release flame scanner

14

11

/43.6 12 21

/41.2 22 34

end of purge

14

11

7 12

24

21

22

14

11

24

21

22

24

24

21

34

34

31

44

/61.3 42

E

21

31

/61.5 32

/92.3 32 41

11

/61.2 22

/43.7 22

31

/43.2

/61.2 12

/36.6 12

8 32 44

control

burner fires

14

N4_N

A2

-42K6

D

A1

A1

A2

-42K5

A2

-42K4 A2

N4

A1

-42K3

A1

-42K2

A1

-X11

A2

protection note according to ISO 16016 consider!

E

ESS-Mode

-14A1

all lines without indication of cross section are

D

/34.7

/33.4

H07Z-K 1,5mm²

C

33

-34K7

B

2

4

-33K4

31

-42K2

11

-42K4

B

44

41

41

42

/100.2 42

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 42

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 42

0-8100-100454-14-3

firing sequence control 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

external trouble

fault

-12A3

shut-down

X4:28

X1:4

/12.3

B

B

E

/13.2

E.7

DI

21 24

22

C

E.7

-14A1.1 /14.4

E.4

DI

E.7

burner fires( I7.7)

end of purge( I1.4)

D

A1

burner fault ( I5.7)

-43K2

14

12 E.4

24

22

/14.1

-13A1

DI

/44.2

/42.5

/42.3

E.7

-14A1

-42K5

11

21

-42K3

2

all lines without indication of cross section are

D

aSC

A2

C

aSC

-43K2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

/42.8

N2

/42.6

N2

/74.6 E

fault

14

11

/35.5 12 24

21

5 22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 43

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 43

0-8100-100454-14-3

firing sequence control 5

=BCC

6

7

75 8

sh.

1

2

/43.7

3

4

5

6

7

8

aSC

A

A

-44K4

/45.7

23

aSC

24

4

E

E.3

B

DI

E.3 C

7

8

1

2

primary air failure (I5.3)

41

33

23

13

S13

-44K4

M12X1,5

A1

-BCC_3005

S10

-X2

D K1

PE

-X2.1

2

+BW

1

SR3C AC/DC24V

K2

42

34

24

14

7

/32.5

/45.2

S12

S21

S14

aBW

A2

-X8

S11

K1

203

202

K2

PE

C

+BN

NO

-17F1

all lines without indication of cross section are

D

/14.1

201

C

-14A1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

/15.8

ΔP

bS

bS

primary air failure

/45.4 E

> min.

atomizing air diff. pressure monitor Zerstäuberluftdifferenzdruckwächter 04.04

04.04 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 44

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 44

0-8100-100454-14-3

primary air pressure 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

aSC

-45K4

aSC

/46.7

23

/44.8

24

4

E

E.2

B

DI

E.2 C

9

combustion air failure (I 5.2)

41

33

23

13

S13

-45K4

M12X1,5

A1

3

-BCC_3005

S10

-X2

3

SR3C AC/DC24V

-X2.1

+BW

D K1

K2

42

34

24

14

7

/32.5

/46.2

S12

S21

aBW

S14

-X8

S11

206

K1

A2

aBW

/44.3

205

K2

PE

C

+BN

NO

-17F2

all lines without indication of cross section are

D

/14.1

204

C

-14A1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

/44.4

P

bS

bS

/46.6

combustion air failure

E

> min.

combustion air pressure monitor Verbrennungsluftdruckwächter 04.03

04.03 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 45

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 45

0-8100-100454-14-3

combustion air pressure 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A aSC

-46K6

aSC

/48.7

23

/45.8

24

6

E

DI

/14.1

E.1

burner swung out ( I5.1

10

C

41

33

23

13

S13

-46K6

M12X1,5

A1

8

-BCC_3005

S10

-X2

SR3C AC/DC24V

D

8

K1

+BW

-X2.1

K2

PE

C

NO

A2

-19S1 +BN

/45.4

bS

bS

burner swung out

/47.5

A1

42

-46K8

/32.2

34

24

14 /30.2

/47.2

7

S12

S21

S11

aBW

A2

-X8

S14

K1

227

225

aBW

/45.3

226

K2

all lines without indication of cross section are

D

-14A1

H07Z-K 1,5mm²

C

E.1

B

protection note according to ISO 16016 consider!

B

/11.7

bS2

bS2

/55.5 E

burner swung out

14

11

/102.7 12 24 limit switch rotary cup atomizer

21

22

Endschalter Drehzerstäuber 04.40

04.40 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 46

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 46

0-8100-100454-14-3

burner swung out 5

=BCC

6

7

75 8

sh.

4

5

6

7

A /35.6

8

ST

-47K5

A

ST

-47K6

31

3

6 24

32

5

34

2

23

1

E

I6

DI

-10A2

DI

/10.2

I7

/10.2

I6

12

11

-BCC_3005

9

10

233

-X8

aBW

/48.2

-47K5

-47K6 A2

PE

NO

-S4

C

PE

NO

-S3

C

-6Y1 +BN

A1

-X8

/46.6

6Y1

/61.6

A2

aBW

D

A1

/46.3

-X2.1

229

228

-X2.1

231

+BW

M12X1,5

9

M12X1,5

232

-BCC_3005

-X2 10

-X2

all lines without indication of cross section are

D

-10A2

C

H07Z-K 1,5mm²

C

I7

B

protection note according to ISO 16016 consider!

B

bS

bS

purge position

/36.2 7

/48.6

/51.6

bS4

bS4

13

14

14

23

24

/36.2 12

33

34

24

43

44

/36.4 22

limit switch compund regulator

limit switch compound regulator

in ignition position

in purge position

Endschalter Verbungregler

Endschalter Verbundregler

53

54

34

in Zündstellung

in Lüftstellung

61

62

8 32

08.02

08.02

71

72

44

83

84

42

08.02

/41.4

/36.4

/11.7 E

ignition position

11

21

31

41

08.02

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 47

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 47

0-8100-100454-14-3

limit switch compund regulator 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

/46.8

8

aSC

aSC

/49.8 A

-48K6

23

A

24

6

B E.0

B

-14A1

E

41

33

23

13

S13

A1

-48K6

S10

13

-X2

SR3C AC/DC24V

6

-BCC_3005

K1 K2

M12X1,5

K2

D

aBW

/47.4

aBW

/49.2 /47.5

-18F3

/30.3

42

24

34

14

S12

S21

S14

S11

bS

/49.6

PE

NC

fire in the windbox

C

+BN

bS

7

-X8

/31.7

217

A2

-X2.1

218

+BW

6

K1

all lines without indication of cross section are

D

C

216

C

E.0

fire in the windbox ( I5.0)

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

/14.1

DI

θ

E

< max.

windbox temperature monitor Luftkastentemperaturwächter 04.09

04.09 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 48

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 48

0-8100-100454-14-3

fire in windbox 5

=BCC

6

7

75 8

sh.

2

3

4

5

6

7

8

A /48.7

aSC

-49K6

aSC

A /50.6

23

1

24

6

B

E.7

B

too high ( I4.7)

14

C

E

41

33

23

13

S13

-49K6

M12X1,5

A1

7

-BCC_3005

S10

-X2

SR3C AC/DC24V

D

-X2.1

7

K1

+BW

K2

PE

C

+BN

NC

/48.6

P

bS

bS

oil pressure too high

42

24

34

14

/102.4

-18F4

8

/50.2

S12

S21

S14

aBW

S11

224

-X8

A2

aBW

K1

/31.4

/48.3

223

K2

all lines without indication of cross section are

D

E.7

oil press

222

C

DI

/14.1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-14A1

/50.6 E

< max.

oil pressure monitor Öldruckwächter 06.04.07

06.04.07 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 49

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 49

0-8100-100454-14-3

oil pressure 5

=BCC

6

7

75 8

sh.

5

6

/49.8

8

aSC

-57K6

aSC

-59K4

-50K6

/59.4 24

/51.7

6 22

/57.6

A

33

A

7

34

4

21

3

24

2

23

1

B

E

DI

E.5

HFO temp too low (I 4.5 )

15

C

41

33

23

13

S13

-50K6

M12X1,5

A1

4

-BCC_3005

S10

-X2

SR3C AC/DC24V

D

4

K1

+BW

-X2.1

K2

PE

C

NO

θ

+BN

/49.6

bS

bS

42 /54.3

8

34

24 /102.3

-18F1

14

/51.2

S12

S21

S14

aBW

S11

212

-X8

A2

aBW

K1

/31.2

/49.3

211

K2

all lines without indication of cross section are

D

/14.1

210

C

-14A1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

E.5

B

/52.6

HFO temperature too low

E

> min.

heavy fuel oil temperature monitor Schweröltemperaturwächter 06.36

06.36 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 50

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 50

0-8100-100454-14-3

HFO temperature 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

/50.8

aSC

aSC

11

-51K6

/52.2

B

B

E

14

E.6

DI

E.6

C

16

HFO temperature high ( I4.6 )

-X2

5

-BCC_3005 M12X1,5

-X8 -51K6

A1

aBW

A2

/50.3

214

-X2.1

215

5

D +BW

PE

C

NC

-18F2

all lines without indication of cross section are

D

/14.1

213

C

-14A1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

12

6

θ

+BN

/47.6

bS4

bS4

/70.4 E

HFO temperature high

14

< max.

11

7 12 24 heavy fuel oil temperature monitor

21

/54.3 22

Schweröltemperaturwächter

34

06.35

31

/102.8 32 44

41

42 06.36

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 51

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 51

0-8100-100454-14-3

HFO temperature high 5

=BCC

6

7

75 8

sh.

1

2

/51.8

3

4

5

6

7

8

aSC

aSC

/53.2 A

-52K6

23

A

24

6

B

E.1

B

E

E.1

17

18 2

C

41

33

23

13

S13

-52K6

M2X1,5

A1

-BCC_3006

S10

-X2

SR3C AC/DC24V

D K1

K2 K2

PE

C

+BO

NC

/50.6

P

bS

bS

42

24 7

34

14 /31.7

/100.7

-52F2

S12

S21

S14

A2

S11

K1

all lines without indication of cross section are

D

DI

steam pressure too high ( I4.1)

1

C

/14.1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-14A1

/53.6

steam pressure too high

E

< max.

steam pressure monitor Dampfdruckwächter BO 034

BO 034 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 52

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 52

0-8100-100454-14-3

steam pressure 5

=BCC

6

7

75 8

sh.

1

2

/52.8

3

4

5

6

7

8

aSC

aSC

/55.7 A

-53K6

23

A

24

6

B

E

DI

E.2

flue gas temperature

19

20 2

too high ( I 4.2 )

C

41

33

23

13

S13

-53K6

M2X1,5

A1

-BCC_3007

S10

-X2

SR3C AC/DC24V

D K1

K2 K2

PE

C

NC

θ

+BO

/52.6

bS

bS

flue gas temperature too high

42

/100.8

24 8

-53F2

34

14 /31.4

S12

S21

S14

A2

S11

K1

all lines without indication of cross section are

D

/14.1

1

C

-14A1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

E.2

B

/56.6 E

< max.

flue gas temperature monitor Rauchgastemperaturwächter BO 041

BO 041 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 53

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 53

0-8100-100454-14-3

flue gas temperature 5

=BCC

6

7

75 8

sh.

1

2

4

5

6

7

8

Ath

* Heating only required for

/34.6

53

-56K6 HFO

-33K4

ESS-mode

A operation

heater has to be disconnected !

/33.4 24

61

-34K6

23

In case of MGO ( HEL )

MGO /59.7

53

A

MDO operation of igniter.

54

-59K7

62

/8.4

3

safety

54

/56.6

21

-37K7

B

24

/38.2 21

-56K6

/50.6

/56.6 HFO

20

N

15

N

19

43

/40.4

18

17

16

41

low

C

14

HFO

44 71

-50K6

42

/59.7

/68.2

13

-BCC_2005

12

11

-X1

107

15 106

*

+BN

PE

N

L

PE

N

-9E2 L

PE

14

50

49

48

47

46

L

PE

+BN

D

-X8

-5E2 N

-5E1 N

+BN

-X8

105

11 45

62

61

60

59 PE

+BN

-X1.1

-X8

-5E6 N

PE

N

N

+BN

-X8

-5E5 L

-5E4 PE

-5E3

-X8

L

-X8

58

57

56

55

-X1.1

L

-X8

+BN

13 54

53

-X1.1 52

-X1.1

51

+BW

12

M16G1,5

L

E

/28.5

-59K7

all lines without indication of cross section are

D

A54

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

oil valves

72

22

22

-38K2

/51.6

high

24

HFO

C

B

21

-51K6

24

22

ignition /37.7

+BN

E

burner heater

ESV valve heater

oil block heater

oil feed hinge heater

oil distributor heater 1

oil distributor heater 2

igniter heater

Brennerheizung

ESV-Ventilbeheizung

Ölblockbeheizung

Ölscharnierbeheizung

Ölverteilerbeheizung 1

Ölverteilerbeheizung 2

Zünderbeheizung

01.06.11

06.01.22

06.49

01.06.10

01.06.10

12.17

(OPTION) 01.06.11

06.01.22

06.49

01.06.10

12.17

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 54

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 54

0-8100-100454-14-3

heating tracer 5

=BCC

6

7

75 8

sh.

1

2

/29.8

3

4

as

as

5

6

7

8

/56.2

A

A /53.8

aSC

aSC

11

-55K6

/56.8

14

12

6

B

E

DI

E.3

oil return

C

23

24 4

-BCC_3008

2

-BCC_3008

-X2

1

-X2

3

22

21

to tank ( I3.3)

M4X1,5

M4X1,5

A2

PE

NO

C

PE

+F

A1

-55K6

A2

-55K5

-55S3 NO

-55S2

A1

D

all lines without indication of cross section are

D

/13.4

C

C

-13A1.1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

E.3

B

+F /46.8

bS2

bS2

fuel oil circulating to pump

14

11

limit switch 3-way-valve

return line in tank position

return line in pump position

Endschalter 3-Wege-Ventil

Endschalter 3-Wege-Ventil

Rückleitung in Tankstellung

Rückleitung in Pumpenstellung

FO 003

FO 003

FO 003

FO 003

24

14

E

11

7 12

/57.6 12

limit switch 3-way-valve

/59.4

fuel oil circulating to tank

21

24

21

22

22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 55

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 55

0-8100-100454-14-3

selection fuel 5

=BCC

6

7

75 8

sh.

1

2

/55.4

3

as

as

4

5

6

7

/57.2

8

/55.8

aSC

aSC

/57.8 A

-56K6

13

A

14

6

E

E.6

B

DI

E.6 C HFO

27

28 2

-BCC_3012

2

-BCC_3010

-X2

1

-X2

1

26

25

operation ( I2.6)

M4X1,5

M4X1,5

-56K6

+F

A2

PE

NO

C

PE

-56S3 NO

-56S2

A1

D

all lines without indication of cross section are

D

/13.4

C

C

-13A1.1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

+F /53.7

bS

bS

/57.6

HFO operation selected

8 limit switch 3-way-valve

limit switch 3-way-valve

/31.2

pre line in heavy fuel oil position

pressure controller in heavy fuel oil position

Endschalter 3-Wege-Ventil

Endschalter 3-Wege-Ventil

/54.6

Zuleitung in Schwerölstellung

Druckregler in Schwerölstellung

/54.3

FO 002

BN 010

/31.2

/100.2

/102.3 FO 002

/102.3

BN 010

13

14

23

24

33

34

43

44

53

54

61

62

71

72

83

84

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 56

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 56

0-8100-100454-14-3

selection fuel 5

=BCC

6

7

75 8

sh.

1

2

/56.2

3

as

as

4

5

6

7

/59.2

8

/56.8

aSC

aSC

/59.8 A

-57K6

33

A

34

6

/13.4

E

DI

E.7 C MDO

-X2

-55K5

11

-X2

32

31

30

29

operation ( I2.7)

14

12

4

3

-BCC_3012

4

-BCC_3010

3

/55.5

M4X1,5

M4X1,5

-57K6

+F

A2

PE

NO

C

PE

NO

-57S3 C

-57S2

A1

D

all lines without indication of cross section are

D

-13A1.1

H07Z-K 1,5mm²

C

E.7

B

protection note according to ISO 16016 consider!

B

+F /56.6

bS

bS

/59.7 E

MDO selected

/31.2 limit switch 3-way-valve

limit switch 3-way-valve

pre line in light fuel oil position

pressure controller in light fuel oil position

/50.6

Endschalter 3-Wege-Ventil

Endschalter 3-Wege-Ventil

Zuleitung in Leichtölstellung

Druckregler in Leichtölstellung

FO 002

8 /100.3

BN 010

FO 002

/31.2

13

14

23

24

33

34

43

44

53

54

61

62

71

72

83

84

BN 010

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 57

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 57

0-8100-100454-14-3

selection fuel 5

=BCC

6

7

75 8

sh.

1

2

/57.2

3

4

5

6

as

as

7

8

/61.2

/57.8

aSC

aSC

/63.7

A

A

43

-59K7

44

7

E

DI

/14.4

E.7 C MGO

42

bS2

selection HFO / MDO

14 limit switch 3 way -valve

limit switch 3 way -valve

to HFO / MDO position

toHFO / MDO position

bS2

+F

A2

PE

NO

C

PE

NO

+F /55.6

-59K7

-59S6 +F

/61.2 /57.6

/50.6 22

bS

/31.2 21

limit switch 3 way -valve

limit switch 3 way -valve

to MGO position

to MGO position

/104.5

8

/54.3 /54.6 GO 015

GO 016 GO 015

bS

MGO operation

11

/31.2 12 24

A1

A1

D

C

PE

NO

C

PE

NO

C

4

M4X1,5

-59S5

A2

-59K4

-59S3

+F

41

4

-BCC_3021

M4X1,5

-59S2

3

40

39 3

-BCC_3020

M4X1,5

M4X1,5

-X2

2

-X2

1

-BCC_3021

2

-BCC_3020

-X2

1

-X2

38

37

36

35

operation ( I6.7 )

all lines without indication of cross section are

D

-14A1.1

H07Z-K 1,5mm²

C

E.7

B

protection note according to ISO 16016 consider!

B

13

14

23

24

33

34

43

44

53

54

61

62

71

72

83

84

/70.1

E

GO 016

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 59

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 59

0-8100-100454-14-3

selection fuel oil MGO 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

DIP - Switches /11.7

aT1

aT1

spare spare

/63.2

AI1

AI0

A

A off

on

B

E

2

0VDC/ N

3

PE

-60N3 +CC_D 5

SAACKE,

4

RSE-P II ENGLISCH

2

3

1

9 8 7 6

/64.3

4

0VDC

/64.2

5

+24VDC

/62.2

6

I0

AQ 0+

31

/64.5

7

I1

AQ 0-

32

/64.5

8

I0/I1 GND

AI 0+

33

/62.3

AI 0-

34

/62.3

AI 1+

35

/64.3

/62.3

/63.3

9

Rel 0

AI 1-

36

/64.3

/63.4

10

Rel 1

DI 0

37

/64.6

/63.3

11

Rel

DI 1

38

/64.6

/61.3

12

Y+

DI 2

39

/64.6

/61.3

13

Y

DI GND

40

/64.7

/61.4

14

Y-

C

D

Program: RSEP01_2MpaRev1

/11.7

all lines without indication of cross section are

D

+24VDC/ L1

PE

H07Z-K 1,5mm²

C

1

RS232 Interface

protection note according to ISO 16016 consider!

B

bT1

bT1

/90.1

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 60

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 60

0-8100-100454-14-3

load control 5

=BCC

6

7

75 8

sh.

1

2

/59.5

as

3

as

4

/63.5

5

/42.6

6

7

8

Abn

A

A

/60.3

21

11

-42K6

13

12

14

Y

Y+

Y-

34

32

control

4 12

+CC_D

14

-60N3

/42.6 11

-61K4

31

-42K6

25

-61K2

-X12

B

11

24

23

24

22

14

control

12

burner /42.6

B

12

14

21

-61K3

11

3

E

22

24

12

14 Q2:1

11 5 5

-BCC_2005 M16G1,5

bS2

14

22

increase burner load

11

5 12 24

14

11

4 12 21

24

decrease burner load

14

21

24

66

65

64

PE

E

/63.3

M

11

4 12

5 22

1

+BN

2

A1

-6Y1

bS2

boiler purge

DEC

A2

-61K4

A2

A2

/59.4

A1

A1

/34.5

/38.7

D

BBW1

3

INC

-X8 22

/34.5

-61K3

63

/34.5

-X8

-61K2

21

67

-16K1

24

-X1.1

12

+BW

DO

14

pos.

11

44

42

purge

Q6

68

/10.3

10

-42K2 /42.2

-10A3

4

Q6

4

/10.3

-X1 41

DO

all lines without indication of cross section are

D

-10A3

C

Q2:2

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

3

-M

21 /47.4

22

1~

6Y1

6Y1

/62.2

servo motor compound regulator Stellmotor Verbundregler 08.02 08.02

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 61

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 61

0-8100-100454-14-3

load control 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

-60N3 +CC_D /60.3

6

33

34

8

I0

AI0+

AI0-

GND

E

14

15

2

3

SW

2

3

4

GND

13 1 1

-X3 -BCC_4011 M3X0,75SH

+BW

-X3.3

516

515

514

513

D

-X8

E

G

B

-6Y1 +BN

all lines without indication of cross section are

D

C

H07Z-K 1,5mm²

C

GND

B

protection note according to ISO 16016 consider!

B

E

-R1

Ω

300 /61.8

6Y1

servo motor compound regulator Stellmotor Verbundregler 08.02

08.02 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 62

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 62

0-8100-100454-14-3

load control 5

=BCC

6

7

75 8

sh.

1

2

/60.2

aT1

3

4

5

6

aT1

/61.2

as

as

7

8

/70.1

A

A

REL1

24

REL0

22

REL

/59.8

aSC

aSC

/69.7

29

10

28

/60.3

9

27

+CC_D

3 11

26

-60N3

21

-63K3

-X12

B

E

14

12 E.6

12 E.5

24

22

14

12

/13.4

-13A1.1

DI

/13.4

E.5

C

DI

E.6

steam pressure

steam pressure

low ( I3.5 )

high ( I3.6 )

/61.4

A1 A2

-63K6

A2

-63K5

A1

A1

A2

-63K4

A2

-63K3

A1

D

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-13A1.1

all lines without indication of cross section are

D

5 14

6

4

C

-63K5

11

-63K6

11

11

-63K4

21

B

bS2

E

controlled shut-down

14

11

/35.4 12 24 6 22

steam pressure low/high

14

11

5 12 21

steam pressure high

14

steam pressure low

11

14

8 12

24

21

6 22

11

/11.7

bS2_b

7 12

24

21

/103.6 22

24

21

/103.5 22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 63

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 63

0-8100-100454-14-3

alarm steam pressure 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

-60N3 +CC_D /60.3

5

35

36

4

31

32

37

38

39

40

+24V

AI1+

AI1-

0VDC

AQ0+

Aq0-

DI0

DI1

DI2

DIGND

B

E

GND 2 2

GND

1

-X6 -BCC_6001

S

2

-BCC_4000

1

GND

19

18

17

16

-X3

M2X0,75SH

M5X0,75SH

D

all lines without indication of cross section are

+BO

-

+ECR

+

+

-64B2 -

D

C

1

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

GND

B

E

P/I 0...16bar = 4...20mA

steam pressure transmitter

steam pressure

Dampfdruckmeßumformer

Dampfdruck

BO 033

4...20mA = 0...16bar

CS 080

BO 033 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 64

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 64

0-8100-100454-14-3

steam pressure 5

=BCC

6

7

75 8

sh.

1

2

A

Abo1

/8.4

3

Abo1

4

5

fwl+

/73.2

/70.2 /70.2

GND

fwl-

B

/73.2

N

/54.8

N

/69.2

24 S

25

23

22

21

2

-BCC_4005

M3G1,5

GND

31 GNYE

-BCC_2006

1

-X1

-X3

1

30 2

29

20

C

M2X0,75SH D

2+

PE

5

+BO

3

-68B2

1-

all lines without indication of cross section are

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

GND

fcl-

E

8

A

fcl+

D

7

/69.2

B

C

6

supply unit

L/I

230V/AC

0...100% = 4...20mA

E

boiler water level transmitter Kesselwasserstandsmeßumformer BO 021

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 68

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 68

0-8100-100454-14-3

boiler water level 5

=BCC

6

7

75 8

sh.

2

/68.2

A

3

4

5

Abo1

Abo1

6

7

/76.4

A

/63.8

aSC

-69K5

34

26

24

B

E.3

27

1

2

3

4

5

N 17

-14A1

30

29

28

27

26

/14.1

DI C

E.3

-X3 4

3

1

-BCC_4003

2

boiler water level 1 too low ( I4.3) S

3

41

33

23

13

K1 K2 K2

Gestra NRG 16-50

N

42

/102.2

34

24

7

14

BO 022 N

/32.2

boiler water level electrode

S14

S12

S21

S11

A2

K1

Kesselwasserstandselektrode

/68.2

S13

D

SR3C AC230V

2

GND

+BO

A1

-69K5

-69B3

S10

M4X0,75SH

1

protection note according to ISO 16016 consider!

E

/70.7

Gestra NRS 1-50s

Niveauschalter

all lines without indication of cross section are

D

level limit switch

aSC

5

L

H07Z-K 1,5mm²

C

23

16

B

-69A2

8

33

1

/76.4 E

boiler water level 1 too low

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 69

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 69

0-8100-100454-14-3

low low water 1 5

=BCC

6

7

75 8

sh.

1

2

/63.6

as

3

as

4

5

6

7

8

/73.1 /69.7

A

aSC

aSC

A

31

-70K5

/76.8

34

32

4

B

E.4

B

boiler water level 2 too low ( I4.4 )

33+

PR electronics input

24 V DC

31

42-

OPTION

4 - 20 mA

43+

24

23

22

12+

21

Configuration

GND

/68.4

-70K5

fwl-

-BCC_6001

/51.6 /11.7

GND

A1

fwl+

-X6 3

/68.4

4

/73.1

CURR

4-20mA

UNIT

%

DECP

111.1

DISP

Lo

0.0

DISP

Hi

100.0

REL UNIT

M5X0,75SH

NC

R1 SETP

65%

bS4

ACT DIR R1 Hyst

ON

11

R2 FUNC = SETP R2 CONT

+ECR

R2 SETP

-

21

/102.2 22

ACT DIR R2 Hyst

31

NO

E

10 % INC 0.1%

ERR ACT No

8 32 44

DEL 10 sec.

OFF DEL 5 sec.

/32.2 12

34

Incr 5%

ERR ACT No

boiler water level 2 too low

24

PERC

R1 CONT

bS4_b

14

D

R1 FUNC = SETP

4

bS

3

bS

C

11-

GND

+

E

output

PReasy 4116

4 - 20 mA

/59.8

E.4

<10% delay 10 sec.

all lines without indication of cross section are

D

-70A2

A2

C

DI

/14.1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-14A1

ON

41

DEL 5 sec.

OFF DEL 10 sec.

42

boiler water level ANA OUT = CURR

Kesselwasserniveau

O Range O ERR

4...20mA = 0...100%

4-20mA 23mA

CS 081 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 70

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 70

0-8100-100454-14-3

low low water 2 5

=BCC

6

7

75 8

sh.

1

2

/70.2

3

4

5

6

7

8

as

A

A

Configuration

CURR

4-20mA

UNIT

%

DECP

111.1

DISP

Lo

0.0

DISP

Hi

100.0

REL UNIT

PERC

R1 FUNC = SETP R1 CONT

NC

R1 SETP

85%

ACT DIR

B

R1 Hyst

Incr

B

5%

ERR ACT No ON

DEL 30 sec.

OFF DEL 5 sec.

-73A2

low <18% delay 30 sec. 33+

E

high >85% delay 30 sec.

31

42-

Inc

R2 Hyst

0.1%

43+

24

23

output

C

4 - 20 mA

12+

21

22

DEL 5 sec.

OFF DEL 30 sec.

0-10V

PReasy 4116

4 - 20 mA

18 %

ACT DIR

ON

14 +

input

24 V DC

NO

ERR ACT No

PR electronics

ANA OUT = Volt O Range 0-10V

11-

GND

/13.4

/11.7

GND

A+

bS /13.4 analog

bS_b

M D

input water level /68.4 /68.4

fcl+

0-10 V

fcl-

-13A1.1 /13.4

DI

E.0

boiler water level low ( 3.0 )

E.1

/70.2

all lines without indication of cross section are

D

R2 SETP

E.0

C

R2 CONT

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

R2 FUNC = SETP

-13A1.1 /13.4

DI

E.1

boiler water level high ( I 3.1 ) E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 73

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 73

0-8100-100454-14-3

alarms control boiler level 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

Flt high water

Flt low water O2.4

-15A1

-15A1 A.4

/15.1

A.5

/15.1

DO

A.4

A.5

DO

E

/43.3

A2

A1

-74K7 A2

-74K6

A1

D

all lines without indication of cross section are

D

B

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

C

O2.5

N2

N2

low water alarm

14

high water alarm

11

14

/101.2 12 24

/76.4

E

11

/101.3 12 21

24

22

21

22

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 74

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 74

0-8100-100454-14-3

alarms control boiler level 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

Abo1

/69.5

Abo1

6

7

8

/77.2

A /70.8

aSC

aSC

/77.7

11

-76K5

A

14

12

5

B

N

E.2

A2

N

14

/77.2

-13A1.1

/77.2

/13.4

DI

11

E.2

21

conductivity high ( I3.2)

8 12 24

C

32

33

34

35

1

2

GNYE

3

/100.6 22

-X1

-BCC_2009 M4G1,5

8

PE

2

1

9

+F

16-

-76A3

15+

D

11

12

13

14

2

3

4

Unisafe SL 6005

1

E conductivity monitoring GND

-BCC_4099 M4X0,75SH

Leitfähigkeitsüberwachung FW 007

4

+F

3

-76B3 2

E

N2

conductivity high

all lines without indication of cross section are

D

N2

/69.5

1

C

/74.8

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-76K5

A1

B

conductance probe Leitfähigkeitssonde

FW 007

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 76

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 76

0-8100-100454-14-3

conductivity minitoring 5

=BCC

6

7

75 8

sh.

1

2

/76.5

3

4

5

6

7

8

Abo1

A

A

/76.8

aSC

11

-77K4

B

E

N2_N

14

E.6

oil turbidity

N

11

-14A1

8 12

N_N

24

21

/14.1

/100.6 22

DI

E.6 C

37

38

39

2

4

3

40

36 1

oil detector ( I5.6 )

-X1 -BCC_2008 M4G1,5

D

NC

NO

C

PE

+F

N

-77A2 L

protection note according to ISO 16016 consider!

/7.8

all lines without indication of cross section are

D

/76.6

N2

H07Z-K 1,5mm²

C

/7.8

B

A2

-77K4

/76.6

14

A1

12

4

E Mobrey MCU201

oil turbidity monitoring Öltrübungsüberwachung CO 011

CO 011 F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 77

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 77

0-8100-100454-14-3

oil monitoring 5

=BCC

6

7

75 8

sh.

1

/11.7

2

3

4

5

6

7

8

aT1sch

A

A

11

-7K5

14

12

/7.5

/25.2 24

32

24

22

33

31

/24.2

/27.2

34

-25K2

LT

WH

+CC_D

+CC_D

-90H4 GN

+CC_D

+CC_D

+CC_D

GN

+CC_D

LT

LT

10 10

LT

LT

9 9

LT

LT

8

-90H7

8

LT

7

LT

6

-90H6 GN

LT

LT

7

6

-90H5 GN

C

-90H8 GN

+CC_D

1. control

fuel oil

fuel oil

feed water

feed water

chemical

MGO

MGO

voltage

pump 1

pump 2

pump 1

pump 2

dosing

pump 1

pump 2

selected

/60.2

LT

LT

5 5

LT

LT

4

-90H3 GN

4

LT

LT

3 3

LT

2

LT LT

1

protection note according to ISO 16016 consider!

-90H2

+CC_D

GN

pump

bT1 D

/11.7

bT1_b

all lines without indication of cross section are

D

-90H1

B

/92.1

H07Z-K 1,5mm²

C

LT

1

2

B

-X19

/92.6

34

/22.7

-24K2

23

21

-27K2

34

/20.2

/18.2 34

14

/17.2

-22K7

34

/1.3

-18K2

33

-17K2

33

-1K3

13

-20K2

33

1K6

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 90

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 90

0-8100-100454-14-3

ilumination door 1 ( left) 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

A

A

5

4

3

/11.7

aT2sch

-X12

13

11 14

12

lamp test

14

14

B

Lampenprüfung

18

LT LT

18

LT LT

17

LT

16

LT

17

16 LT LT

15

LT LT

14

LT LT

13

LT LT

15

14

13

12 12

LT LT

+CC_D

/27.6

14

14

14

13

13

13

13

/1.6

/28.4

/30.2

/30.6 14

34

32

14

12 11

protection note according to ISO 16016 consider!

/30.4

-92S7 -27K6

-92H2 +CC_D burner standby

-92H4

-92H3 YE

+CC_D

GN

+CC_D rotary cup

burner in operation

-92H5 GN

+CC_D

-92H6 GN

+CC_D

ignition

comb.air

oil pump

fan

-92H7 GN

+CC_D preheater

-92H9

-92H8 GN

+CC_D 2. control

WH

+CC_D

RD

alarm

voltage selected

D

/13.8

/11.7

bT2

bT2_b

all lines without indication of cross section are

D

-30K2

C

H07Z-K 1,5mm²

C

-30K6

-28K4

LT 11

/90.8

-30K4

/42.5

/35.5 B

-1K6

31

-42K5

11

-35K6

13

/90.8

1K6

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 92

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 92

0-8100-100454-14-3

ilumination door 2 ( right) 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

7

8

Wiring color = orange

VOLT FREE CONTACTS ECR A

A

21

19

17

-X

-X

-X

21

19

17

11

13

-X

15

-X

-X

9

15

13

11

9

7

-X

7

-X

5

-X

3

-BCC_6010

-X

1

-X

5

3

1

+ECR

E

17

-X4

-X4

33

D

22

24

C

-X4

-X4

-X4

20

18

14

16

44

22

34

34

/53.6

22

21

21 24

-53K6

/52.6

/77.4

/76.5

/1.6 44

12

43

43

11 14 12

-X4

-X4

-X4

salt

oil

steam

temp

alarm

shut

fault

contaminated

detected

press

flue gas

too high

too high 22

14

alarm

12

10

down

20

power

18

common

16

common

M24X1,5

-X

-X

-X

-X

-X

-X

20

18

16

14

10

8

-X

22

-X

12

-X

6

burner

4

+ECR

-1K6

/1.3

12

14 10

22

24 8

standby

-1K3

/27.8

-X4

8

service

6

burner

11

21

43

-X4

MDO

-27K8

/27.7

44

-X4

4

operation

service

2

HFO

-27K7

/35.5

6

34

-X4

burner in

-35K6

/57.6

4

44

2

42

/56.6

-X4

-BCC_6010

-57K6

33

41

/42.5

-56K6

-77K4

33

24

34

22

/7.5

-76K5 -42K5

B

-X4

21

-7K5

-X4

21

-X4

-X4

19

-X4

15

13

11

9

7

5

-X4

-52K6

all lines without indication of cross section are

D

-X4

/9.4

2

C

-X4

-9K5

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-X4

33

B

3

1

M24X1,5

-X

-X

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 100

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 100

0-8100-100454-14-3

volt free contacts 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

VOLT FREE CONTACTS ECR

7

8

Wiring color = orange

+ECR

41

39

-X

17

13

9

-X

15

-X

-X

11

-X

7

37

35

-X

5

3

33

31

29

25

41

39

-18K8

-X4

-X4

-X4

42

40

38

C

-X4

FOP 1

FOP 1

level low

level high

fan on

FOP 2

pump 1 on

pump 2 on

dosing

over

over

stand

stand

pump

load

load

by fault

by fault

12

10

8

6

2

-X

-X

-X

-X

-X

42

40

38

36

-X

34

-X

-X

32

-X

30

24

+ECR

28

M24X1,5

26

M24X1,5

on

D

18

chemical

16

fuel oil

FOP 2

14

fuel oil

4

comb.air

24

water

-BCC_6011

14

12

14

12

/18.8

water

-BCC_6010

B

11

11

-17K8

44

44

-X4

/17.8

/3.4

36

44

42

-X4

-X4

43

-3Q3

/3.2

34

-X4

37

35

-3Q2

43

41

-27K2

14

30

28

-X4

-X4

-X4

/27.2

/18.2 14

34

/17.2

-X4

33

31

-18K2

-X4

13

13

-17K2

-X4

32

-X4

14

12 26

14

12

/30.2

24

-X4

-X4

33

11

/74.7

-30K2

29

27

25

23 11

-74K7

/74.7

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

E

-X4

-X4

-74K6

all lines without indication of cross section are

D

-X

M24X1,5

-X4

C

1

-BCC_6011

M24X1,5

B

-X

-X

23

-X

-BCC_6010

27

A

23

A

-X E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 101

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 101

0-8100-100454-14-3

volt free contacts 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

VOLT FREE CONTACTS ECR

7

8

Wiring color = orange 65

63

-X

13

17

-X

15

61

59

9

7

-X

-X

11

57

55

53

-X4

-X4

-X4

-X4

65

63

61

59

57

-X4

-X4

-X4 B

23

-X4

55

53

51

49

45

43

47

-X4

-X4

31

23

34

32

24

14

12

43

44

14

C

66

64

62

60

58

-X4

-X4 D

Flame

comb.air

comb.air

rotary

burner not

emergency

failure

press low

fan

cup

in pos.

stop

over load

over load

fuel oil temp.

14

18

high 16

56

54

-X4

-X4

12

24

-BCC_6012

-X4

10

too low

too high

-X4

8

pressure

M24X1,5

-X

-X

-X

-X

-X

-X

-X

-X

66

64

62

60

56

54

-X

58

-X

52

48

-X

50

M18X1,5

46

+ECR

52

50

temp.

22

-BCC_6011

20

too low

fuel oil

-X4

6

level 2

too low

fuel oil

-X4

4

water

level 1

-X4

-X4

water

/51.6

/9.6

/2.2

2

-X4

-51K6

84 48

46

44

-X4

-9K6

/46.7

-2Q2

/56.6 HFO

11

-46K8

/2.6 12

14

12

43

11

11

33

-2Q5

44

83

HFO

-27K5 /27.5

/27.4

/49.6

/56.6

-56K6

-27K4

34

24

22

71

21

-56K6

/70.4

24

-49K6

72

/69.5

24

23

-70K5

44

protection note according to ISO 16016 consider!

E

-X

/50.6

-69K5

all lines without indication of cross section are

D

-X4

-50K6

H07Z-K 1,5mm²

C

-X

M18X1,5

-X4

B

-X

5

23

-BCC_6012

M24X1,5

-X

3

-X

-X 21

19

-BCC_6011

-X

1

-X

47

45

43

+ECR

51

A

49

A

-X E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 102

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 102

0-8100-100454-14-3

volt free contacts 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

VOLT FREE CONTACTS ECR

7

8

Wiring color = orange

A

A

83

81

79

-X

17

13

-X

15

-X

-X

11

-X

9

5

77

75

73

-X

7

-X

3

-BCC_6013

-X

1

-X

71

69

67

+ECR

E

21 24

24

22

14

12

22

11

21

/63.5

/63.6

-X4

-X4

-X4

feed water

steam

steam

pump 1 on

pump 2 on

pump 1

pump 2

pump 1

pump 2

press.

press.

overload

overload

stand by fault

stand by fault

low

high

12

14

feed water

10

feed water

8

feed water

6

feed water

4

84

82

80

78

-X4

-X4

D

18

-X4

16

-X4

76

72

-X4

2

B

-X4

-63K5

feed water

-BCC_6013

83

81

79

-X4

-63K6

/22.2 12

24

-22K3

14

/20.3 22

44

11

21

-20K3

/22.8

34

77

75

73

71 31

-22K8

-X4

-X4

C

70

32

-X4

74

43 68

-X4

-X4

/4.2

/22.7 44

/20.2

-X

-X

-X

-X

-X

-X

-X

84

82

80

78

76

74

+ECR

72

M18X1,5

70

all lines without indication of cross section are

D

-X4

-22K7

68

C

-X4

-4Q2 -20K2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-X4

43

B

69

67

M18X1,5

-X

-X

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 103

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 103

0-8100-100454-14-3

volt free contacts 5

=BCC

6

7

75 8

sh.

1

2

3

4

5

6

VOLT FREE CONTACTS ECR

7

8

Wiring color = orange

A

A

101

99

-X

15

13

-X

17

97

-X

-X

11

-X

9

5

95

93

91

-X

7

-X

3

-BCC_6014

-X

1

-X

89

87

85

+ECR

E

MGO

pump 1

pump 2

overload

overload

stand by fault

stand by fault

101

99

97 23 24

-X4

102

98

100

C

-X4

D

MGO

18

service 16

8

14

12

MGO

pump 2

10

MGO

pump 1

6

MGO

pump 2 on

4

MGO

2

-X4

-X4

pump 1 on

B

-X4

/59.7

96

-X4

MGO

-BCC_6014

11

11 14

12 94

-X4

-X4

14

-X4

-59K7

/25.8

44

/24.8

92

90

-X4

-25K8

12

/3.7

-X4

-X4

-24K8

14 88

86

-X4

95

93

-X4

43

43

-3Q7

44

13

-X4

/3.5

/25.2 14

91

89

-X4

-3Q5 -25K2

/24.2

-X

-X

-X

-X

-X

-X

-X

-X

102

100

98

96

94

92

+ECR

90

M18X1,5

88

all lines without indication of cross section are

D

-X4

86

C

-24K2

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-X4

13

B

87

85

M18X1,5

-X

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

circuit diagram / Stromlaufplan 104

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC_M sheet 104

0-8100-100454-14-3

volt free contacts 5

=BCC

6

7

75 8

sh.

R. modification

cable external

free

date date 25.07.2011

drawn ROS

check ROS

name standard

0 -BCC_1005 M4G1,5

origin 1 2 3 GNYE

0 -BCC_1006 M4G2,5

0 -BCC_1010 M4G1,5

0 -BCC_1011 M4G1,5

replaced for 1 2

0 -BCC_2020 M3G1,5

Control Cabinet Boiler

replaced by

PE

+FWP1-4M2 +FWP1-4M2

1 2 3 GNYE

1

V PE L1 L2 L3 PE

+BN-5E3-X +BN-5E3-X +BN-5E3-X +BN-5E3-X

3 GNYE

+FW-5M2

0 -BCC_1012 M4G4 +FW-5M2

U

V W

+FWP1-4M2

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

/5.4

/5.4

/5.4

/5.4

/5.2

/5.2

/5.2

/4.2

/4.2

/4.2

+CC_MPE

-28K4

-28K4

-28K4

+CC_MPE

-27K2

-27K2

+CC_MPE

-20K1

-20K1

-20K1

+CC_MPE /4.2

-18K2 /3.4

-18K2

-18K2

+CC_MPE

-17K2

-17K2

-17K2

+CC_MPE

-30K2

-30K2

-2T5

+CC_MPE

-30K6

-30K6

-30K6

+CC_MPE

-30K4

-30K4

/3.4

/3.4

/3.4

/3.2

/3.2

/3.2

/3.2

/2.6

/2.6

/2.6

/2.6

/2.4

/2.4

/2.4

/2.4

/2.3

/2.3

/2.2

internal

target sign

6

4

2

6

4

2

6

4

2

6

4

L

6

4

2

6

4

6

4

2

24

14

terminal

+FW-5M2

U

W

+FOP2-3M3

PE

V

+FOP2-3M3

+FWP1-4M2

U

+FOP2-3M3

+FOP2-3M3

W

3 GNYE

PE

2

+FOP1-3M2

1

+FOP1-3M2

V

PE

+BN-2M5

3 GNYE

U

W

+BN-2M5

2

+FOP1-3M2

V

+BN-2M5

1

+FOP1-3M2

U

+BN-2M5

PE

+F-2M3

3 GNYE

V

2

W

1

+F-2M3

U

3

2

/2.2

item

+F-2M3

660

0 -BCC_1004 M4G2,5 +F-2M3

0 -BCC_1003 M4G4 +BW-X8

item 658

terminal 656

type

+BW-X8

lace connection

number of terminals : 47

comment

+BW-X8

terminal number 1

wire connection

strip : -X0

presentation

654

terminal block

free

+BW-X8

external

target sign

protection note according to ISO 16016 consider! cable internal

0

0

0

0

1 2 3 GNYE

2 GNYE

terminalblock diagram / Klemmenplan 1

=BCC+CC_M-X0

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 1 31 sh.

R. modification

cable external

free

terminal

item

0 -BCC_1008 M4G1,5

date name standard 1

date 25.07.2011

drawn ROS

check ROS 2

0 -BCC_1009 M4G1,5 1

origin 2

4 -BCC_1000 M4G25 5

+CC_D-1Q2

4 -BCC_1001 M4G35

replaced for

5

+CC_D-1Q5 -2PE

-2L3

-2L2

-2L1

/1.5

/1.5

/1.5

/1.5

+CC_MPE

+MSB2-X

+MSB2-X

+MSB2-X

2L3

2L2

2L1

2

2PE

3

1

+MSB2-X

1

+CC_D-1Q5

1L3 +CC_MPE

+MSB1-X /1.2

1L2 /1.2

1L1 +MSB1-X

+MSB1-X /1.2

0 -BCC_1001 M4G35

+CC_D-1Q5

-1PE

-1L3

-1L2

-1L1

/1.2

6

4

6

4

2

1PE

3

+CC_MPE /3.8

-25K2

-25K2

+CC_MPE

-24K2

-24K2

2

1

+MSB1-X

1

39

/3.7

/3.7

/3.7

/3.6

/3.5

/3.5

-24K2

terminal

+CC_D-1Q2

PE

+MGOP2-3M7

38

37

36

35

34

33

/3.5

internal

target sign

0 -BCC_1000 M4G25

+CC_D-1Q2

V W

U

+MGOP2-3M7

+MGOP2-3M7

PE

+MGOP1-3M5

+MGOP2-3M7

V

type

W

lace connection

+MGOP1-3M5

comment

number of terminals : 47

presentation

+MGOP1-3M5

terminal number 32

wire connection

strip : -X0

item

U

terminal block

free

+MGOP1-3M5

external

target sign

protection note according to ISO 16016 consider! cable internal

0

3

3

GNYE GNYE

3 GNYE

0 3 GNYE

Control Cabinet Boiler terminalblock diagram / Klemmenplan 2

replaced by

=BCC+CC_M-X0

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 2 31 sh.

cable external

free

R. modification date

16 -BCC_2005 M16G1,5

date 25.07.2011

drawn ROS

check ROS

name standard 7 8 9

origin 10

4 5 12 01 02 05 PE

+BW-X1.1 +BW-X1.1 -X1 +BN-5E3 +BN-5E3 +BN-5E3 +BN-5E3

4 5

0 -BCC_2022 M4G1,5 1

replaced for 2 11 12 13

0 -BCC_3014 M2X1,5

0 -BCC_3016 M2X1,5

Control Cabinet Boiler

replaced by 14

1 1

14

+FW005-19F7

2 GNYE

0 -BCC_2009 M4G1,5

=BCC+CC_M-X1 1

terminalblock diagram / Klemmenplan 3

8 L N PE NC

+F-77A2 +F-77A2 +F-77A2

+F-76A3

+F-77A2

0 -BCC_2008 M4G1,5 +F-76A3

2 PE

+F-76A3

1

1

+F-76A3

PE

13

+FW005-19F7

+BO-68B2

14

+FO 006-16F7

5

13

+FO 006-16F7

+BO-68B2

0 -BCC_2006 M3G1,5 3

15

+BO-68B2

15

14

11

13

+BW-X1.1

+BW-X1.1

+BW-X1.1

+BW-X1.1

12

12

3

+BW-X1.1

3

+BW-X1.1

11

2

+BW-X1.1

2

22

/19.8

28

/77.3 /77.3

40

/77.3

/77.2

/77.2

/76.5

/76.5

/76.5

/76.4

/68.2

/68.2

39

38

37

36

35

34

33

32

31

30

/68.2

/19.8

27

29

/19.7

/19.7

/16.7

26

25

24

/16.7

/5.6

21

23

/5.6

20

/54.7

/54.6

/54.3

/54.2

/5.5

/5.5

/5.5

/5.5

/61.5

/61.5

/38.6

/37.3

/37.2

/34.4

/34.4

/34.4

/34.3

/34.2

/54.8

19

18

17

16

15

14

13

10

9

8

7

1

+BW-X1.1

6

5

4

3

PE

GNYE 1

+BW-X1.1

10

6

+BW-X1.1

9

terminal

+BW-X1.1

item 2

type

8

lace connection

7

/34.3

presentation

+BW-X1.1

comment

number of terminals : 42

12

15

-77K4

-X11

-76K5

-69K5

-69A2

A1

10

A1

A2

23

17

16

-69A2 -69A2

2

3

A1

-8F4

-X30

-19K7

-X11

A1

-X11 -16K7

3

14

21

44

42

21

A1

7

44

12

12

14

82

34

-X20

-40A3

-38K2

-56K6

-50K6

-51K6

-28K4

-X11

-18K2

-X1

-61K2

-61K2

-34K7

-34K7

33

A2

-33K4

-34K7

A2

24

14

34

-34K6

-39K3

-38K2

-34K6

item

+BW-X1.1

terminal number 1

wire connection

strip : -X1

internal

target sign

terminal

6

terminal block

free

+BW-X1.1

external

target sign

protection note according to ISO 16016 consider!

0

0

1 2 4 3

3 GNYE 2 GNYE 3

2 2

0

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 3 31 sh.

cable internal

cable internal

33 -X11

lace connection

type

14

0 -BCC_3018 M2X1,5

1

2

cable external

free

+GO 006-23F7

item

13

external

terminal

+GO 006-23F7

41

terminal number

42

wire connection

/23.7

/23.7

strip : -X1

terminal block

comment

number of terminals : 42

presentation

-23K7

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

A1

3 -X40

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 4

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X1

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 4 31

sh.

cable external

free

R. modification

terminal

item

0 -BCC_3001 M2X1,5

date date 25.07.2011

drawn ROS

check ROS

name standard origin

2 3 8 9

+BW-X2.1 +BW-X2.1 +BW-X2.1

2

+BW-X2.1

1

1

2 -BCC_3005 M12X1,5 1 2 3 8 9

replaced for

4

+BW-X2.1

5

0 -BCC_3012 M4X1,5

Control Cabinet Boiler

replaced by

NO C NO

+F-57S3 +F-57S3

1

+F-57S2

2

C

1

+F-57S2

4

C

+F-56S2

3

NO

+F-56S2

2

+F-56S3

C NO

+F-55S3

1

+F-56S3

C NO

+F-55S3

0 -BCC_3010 M4X1,5 C

0 -BCC_3008 M4X1,5 NO

2

+F-55S2

NC

+BO-53F2

1

+F-55S2

C

2

NC

1

+BO-53F2

0 -BCC_3007 M2X1,5 +BO-52F2

5

7

+BW-X2.1

4

C

6

7

+BO-52F2

10

+BW-X2.1

6

+BW-X2.1

0 -BCC_3006 M2X1,5 10

+BW-X2.1

/9.3

6

3 4 3 4

2

=BCC+CC_M-X2

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

/57.4

/57.3

/57.2

/57.2

/56.4

/56.3

/56.2

/56.2

/55.4

/55.3

/55.2

/55.2

/53.2

/53.2

/52.2

/52.2

/51.2

/50.2

/49.2

/48.2

/47.4

/47.2

/46.2

/45.2

/44.2

/44.2

/9.3

7

/9.3

5

/9.3

/9.2

4

3

2

/9.2

23

-55K5

-56K6

-55K5

-55K6

-12K2

11

A1

A1

A1

11

A1

-52K6 -53K6

23

-53K6

A1

23

-52K6 -52K6

11

A1

22

A1

A1

A1

A1

A1

A1

-51K6

-51K6

-59K4

-49K6

-48K6

-47K5

-47K6

-46K8

-45K4

A1

23

-44K4 -44K4

21

S12

2

-42K5

-9K5

-X12

internal

target sign

terminal

+BW-X2.1

NC

0 -BCC_3002 M2X1,5 +F-9S3

2

C

1

NC

type

+F-9S3

lace connection

number of terminals : 40

comment

+F-9S2

terminal number 1

wire connection

strip : -X2

presentation

C

terminal block

item

+F-9S2

external

target sign

protection note according to ISO 16016 consider! free

0

terminalblock diagram / Klemmenplan 5

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 5 31 sh.

cable internal

cable internal

A1 -59K7 /59.7

/59.6

/59.5

-42K6 /59.5

/59.3

4

42 NO +F-59S6

3

41 C

40 NO

+F-59S6

2

+F-59S5

1

39 C +F-59S5

37

38 NO +F-59S3

2

3

4

external

item free

36

1

terminal

C

C +F-59S2

35

terminal number

NO

type

+F-59S3

lace connection

+F-59S2

wire connection

/59.2

/59.2

strip : -X2

terminal block

comment

number of terminals : 40

presentation

/59.3

-59K4

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

11

A1

0

free

0 -BCC_3020 M4X1,5

cable external

0 -BCC_3021 M4X1,5

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 6

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X2

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 6 31

sh.

cable external

free

R. modification date date 25.07.2011

drawn ROS

check ROS

name standard

6 -BCC_4002 M5X0,75SH

origin 1 2 3 4 5

0 -BCC_4011 M3X0,75SH

replaced for

0 -BCC_4005 M2X0,75SH

1 2

6 1 2

+BW-X3.2 +BW-X3.3 +BW-X3.3

Control Cabinet Boiler

replaced by

/64.3

18

6

24

2 3

+BO-69B3 +BO-69B3

S 1 2 3 4

30

29

28

GND

+BO-69B3

/69.4

/69.4

/69.3

/69.3

/69.3

/68.4

/68.4

23

25

/68.4

22

-69A2

-69A2

-69A2

-69A2

-69A2

1

2

3

4

5

42-

43+

-70A2 /68.4

-70A2

42-

-73A2 /68.4

21

43+

35

5

34

33

/68.3

-73A2

+CC_D-60N3

+CC_D-60N3

+CC_D-60N3

+CC_D-60N3

+CC_D-60N3

20

/64.3

/64.3

17

19

/64.2

/62.3

/62.3

/62.2

6

5 -40A3

-40A3 /40.6

4 /40.5

3 -40A3

-40A3 /40.5

2

-40A3

1

6

5

4

3

2

1

/40.6

-40A3

-39A3

-39A3

-39A3

-39A3

-39A3

-39A3

/40.6

/40.6

/39.6

/39.5

/39.5

/39.6

/39.6

16

15

14

13

12

11

10

9

8

7

6

5

4

27

2

26

1

1

2

+BO-69B3

1

-SH

1-

0 -BCC_4003 M4X0,75SH +BO-68B2

S

2+

5

+BW-X3.2

S

+BO-68B2

4

+BW-X3.2

5

-

3

+BW-X3.2

4

+BO-64B2

2

+BW-X3.2

3

3

1

+BW-X3.2

2

+

6

+BW-X3.1

1

+BO-64B2

5

3

2

/39.6

internal

target sign

terminal

+BW-X3.3

4

6 -BCC_4001 M5X0,75SH +BW-X3.1

0 -BCC_4000 M2X0,75SH +BW-X3.1

item 3

terminal 2

type

+BW-X3.1

lace connection

number of terminals : 30

comment

+BW-X3.1

terminal number 1

wire connection

strip : -X3

presentation

1

terminal block

item

+BW-X3.1

external

target sign

protection note according to ISO 16016 consider! free

0

3

terminalblock diagram / Klemmenplan 7

=BCC+CC_M-X3

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 7 31 sh.

cable internal

cable external

free

R. modification date date 25.07.2011

drawn ROS

check ROS

name standard

6 7 8 9

+ECR-X +ECR-X +ECR-X +ECR-X

2 3 4 5 6 7 8 9

origin 10 11 12

replaced for 13 14 15 16 17 18 19

Control Cabinet Boiler

replaced by 20 21 22 23

27 28 29 30 31 32 33

+ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X

2 3 4 5 6 7 8 9

=BCC+CC_M-X4 10 11 12 13

terminalblock diagram / Klemmenplan 8 14 15 16 17 18 19 20 21 22 23

51 52 53 54 55 56 57

+ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X

2 3 4 5 6 7 8 9

0-8100-100454-14 /3-32

10

0-8100-100454-14-3

11 12 13 14 15

31

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

64

63

62

61

60

59

58

50

1

+ECR-X

49 +ECR-X

47

46

45

44

43

42

41

40

39

38

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

37

36

35

48

24

+ECR-X

0 -BCC_6012 M18X1,5 +ECR-X

+ECR-X

+ECR-X

+ECR-X

34

26

1

+ECR-X

25 +ECR-X

23

22

21

+ECR-X

+ECR-X

+ECR-X

+ECR-X

20

19

18

17

16

15

14

13

12

11

24

24

+ECR-X

0 -BCC_6011 M24X1,5 +ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

10

5

1

+ECR-X

4

0 -BCC_6010 M24X1,5 +ECR-X

item +ECR-X

terminal 3

64

63

62

61

60

59

58

57

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

type

2

lace connection

+ECR-X

comment

number of terminals : 102

/102.8

/102.8

/102.7

/102.7

/102.7

/102.7

/102.6

/102.6

/102.6

/102.6

/102.5

/102.5

/102.4

/102.4

/102.4

/102.4

/102.3

/102.3

/102.2

/102.2

/102.2

/102.2

/101.8

/101.8

/101.7

/101.7

/101.6

/101.6

/101.6

/101.6

/101.5

/101.5

/101.5

/101.5

/101.4

/101.4

/101.3

/101.3

/101.3

/101.3

/101.2

/101.2

/100.8

/100.8

/100.7

/100.7

/100.6

/100.6

/100.6

/100.6

/100.5

/100.5

/100.4

/100.4

/100.4

/100.4

/100.3

/100.3

/100.3

/100.3

/100.2

/100.2

/100.2

/100.2

presentation

+ECR-X

terminal number 1

wire connection

strip : -X4

-9K6

-9K6

-46K8

-46K8

-2Q2

-2Q2

-2Q5

-2Q5

-27K5

-27K5

-27K4

-27K4

-49K6

-49K6

-56K6

-56K6

-70K5

-70K5

-69K5

-69K5

-18K8

-18K8

-17K8

-17K8

-3Q3

-3Q3

-3Q2

-3Q2

-27K2

-27K2

-18K2

-18K2

-17K2

-17K2

-30K2

-30K2

-74K7

-74K7

-74K6

-74K6

-53K6

-53K6

-52K6

-52K6

-77K4

-77K4

-76K5

24

23

14

11

44

43

44

43

14

11

14

11

34

33

84

71

24

21

24

23

14

11

14

11

34

33

34

33

44

41

14

13

14

13

34

33

14

11

14

11

34

33

34

33

24

21

24

21

44 -76K5

-1K6

21

14

11

14

11

24

21

44

43

34

33

44

41

44

internal

target sign

-1K3

-7K5

-27K8

-27K8

-27K7

-27K7

-35K6

-35K6

-57K6

-57K6

-56K6

-9K5

-42K5

-42K5

item

1

terminal block

terminal

+ECR-X

external

target sign

protection note according to ISO 16016 consider! free

0

16

=BCC

+CC_M sheet 8 sh.

cable internal

cable external

free

R. modification

item

date

terminal

18 -BCC_6012 M18X1,5

name standard 17

date 25.07.2011

drawn ROS

check ROS

70 71 72 73 74 75

+ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X

2 3 4 5 6 7 8 9

origin 10

replaced for 11 12 13 14 15 16 17

87 88 89 90 91 92 93

+ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X +ECR-X

2 3 4 5 6 7 8 9

Control Cabinet Boiler

replaced by 10 11 12

=BCC+CC_M-X4 13 14 15 16 17

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

102

101

100

99

98

97

96

95

94

86

+ECR-X

1

+ECR-X

85

83

82

81

80

79

78

77

+ECR-X

0 -BCC_6014 M18X1,5 84

18

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

+ECR-X

76

69

1

+ECR-X

68

+ECR-X

18

+ECR-X

0 -BCC_6013 M18X1,5 102

101

100

99

98

97

96

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

79

78

77

76

75

74

73

72

71

70

69

68

67

type

66

lace connection

67

comment

number of terminals : 102

/104.6

/104.6

/104.6

/104.6

/104.5

/104.5

/104.5

/104.5

/104.4

/104.4

/104.3

/104.3

/104.3

/104.3

/104.2

/104.2

/104.1

/104.1

/103.6

/103.6

/103.6

/103.6

/103.5

/103.5

/103.5

/103.5

/103.4

/103.4

/103.3

/103.3

/103.3

/103.3

/103.2

/103.2

/103.2

/103.2

/102.8

/102.8

presentation

66

terminal number 65

wire connection

strip : -X4

-59K7

-59K7

-25K8

-25K8

-24K8

-24K8

-3Q7

-3Q7

-3Q5

-3Q5

-25K2

-25K2

-24K2

-24K2

-63K5

-63K5

-63K6

-63K6

-22K2

-22K2

-20K2

-20K2

-22K8

-22K8

-4Q2

-4Q2

-22K7

-22K7

-20K1

-20K1

-51K6

-51K6

item

+ECR-X

65

terminal block internal

target sign

24

23

14

11

14

11

44

43

44

43

14

13

14

13

22

21

22

21

14

11

14

11

24

21

44

43

34

31

44

43

34

31

terminal

+ECR-X

+ECR-X

external

target sign

protection note according to ISO 16016 consider! free

0

18

terminalblock diagram / Klemmenplan 9

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 9 31 sh.

cable internal

cable internal

11-70A2

32

12+ -70A2

+CC_D-60N3

+

-

+

-

+ECR-X

+ECR-X

+ECR-X

+ECR-X

1

terminal number

4

type

3

lace connection

2

wire connection

/70.7

/64.5

strip : -X6

terminal block

comment

number of terminals : 4

presentation

/70.6

+CC_D-60N3

internal

item

1

2

3

4

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

/64.5

31

0

free

item 2 -BCC_6001 M5X0,75SH

cable external

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 10

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X6

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 10 31

sh.

cable internal

0 l

free

terminal number

-2T5 2

type

+CC_D-2P5

lace connection

1

wire connection

+CC_D-2P5

strip : -X10

terminal block

comment

number of terminals : 2

/2.5

presentation

/2.6

+CC_MPE

internal

item

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

item 0

cable external

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 11

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X10

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 11 31

sh.

cable external

free

R. modification date date 25.07.2011

drawn ROS

check ROS

name standard origin replaced for

Control Cabinet Boiler

replaced by

7 7 1 2

2/4 1

+CC_D-19S3 +CC_D-19S4 +CC_D-27S2 +CC_D-27S2

+CC_D-30S2 +CC_D-30S2

terminalblock diagram / Klemmenplan 12

=BCC+CC_M-X11

3 1 2/4 1 3 1 2 8

7 7

+CC_D-35S5 +CC_D-35S5 +CC_D-35S5 +CC_D-39S2 +CC_D-39S2 +CC_D-39S2 +CC_D-42S6 +CC_D-42S6 +CC_D-23S3

+CC_D-23S3 +CC_D-23S4 +CC_D-30P5

14 2/4

+CC_D-36S5

3

8

13

8

+CC_D-19S3 +CC_D-19S4

+CC_D-36S5

7

+CC_D-30S2

7

+CC_D-16S4

14

+CC_D-9S8

+CC_D-16S3

A2

-77K4

8

37

-X1

+CC_D-16S3

A2

-42K6

item 13

terminal 36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

/30.5

/23.5

/23.3

/23.4

-30K4

-25K7

A1

14

14

-X1 -24K7

2L 41

-15A1.1

A1

72 -42K6

-34K7 /42.6

62 /42.6

52 -34K7

-34K7 /39.2

24

-34K7

11

A1

X3:18

A1

12

33

Q3:1

/39.2

-63K3

-34K7

-12A3

-36K7

-42K5

-2Q5

-10A2

/39.2

/35.4

/35.4

/35.4

/36.6

/36.6

/30.2

/30.2

14

23

-20K1 -46K6

11

-22K7

/30.2

14 /27.2

11 -5F2

-22K6 /27.2

A.2

-13A1

25

3

14

/19.5

-X1

-X21

-18K7

14

23 -17K7

34 -X1

A1 -9K7

-9K8

/19.3

/19.4

/16.5

/16.3

/16.5

/9.7

A2

A2 -27K2

-9K8

10

/7.6

/7.6

9

6

-8B6 /7.6

A2

8

-7K5

+CC_D-30P5

13

1

Q4:1

/7.6

/7.6

6

+CC_D-9S8

-8F6

-10A3

internal

target sign

7

/7.6

/7.6

5

4

/7.6

/7.6

2 3

/7.6

terminal number

-X1

type

0V

lace connection

number of terminals : 36

comment

1

presentation

A1

wire connection

strip : -X11

item

-7T2

terminal block

terminal

-7K5

external

target sign

protection note according to ISO 16016 consider! free

0

0

0

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 12 31 sh.

cable internal

cable external

free

R. modification

terminal

item

date date 25.07.2011

drawn ROS

check ROS

name standard origin replaced for

16

-X12

Control Cabinet Boiler

replaced by

6 13 12 14 9 10

2

6 6

+CC_D-60N3 +CC_D-60N3 +CC_D-60N3 +CC_D-60N3

+CC_D-23S3

+CC_D-23S3 +CC_D-23S4

6

+CC_D-19S3

+CC_D-60N3

2

+CC_D-19S3

+CC_D-19S4

6

+CC_D-16S4

19

6

-X12

+CC_D-16S3

E.3

-13A1

11

=BCC+CC_M-X12

terminalblock diagram / Klemmenplan 13

32

31

/23.4

/23.3

31

-14A1.1

E.5

E.4

-35K2 -14A1.1

13

29

-3Q7

/63.4

28

/23.3

A1

-63K4 /63.4

27

30

A1

A1

A1

24

E.1

-63K3

-61K4

-61K3

-42K6

-13A1

E.0

-22K8 -13A1

11

19 -19K7

-X12

E.4

13

-3Q3

-13A1

11

-16K7

/63.4

/61.4

/61.3

/61.3

/19.4

/19.3

/19.3

/16.4

/16.3

/16.3

31

16

A2

A2

/63.3

26

25

24

23

22

21

20

19

18

17

16

-X12

2

+CC_D-90H8

+CC_D-16S3

-73A2 16

-X12

-47K6

-X12

/11.6

/11.6

-46K8

+CC_MPE

+CC_D-92H9

16

15

A2

-63K6

/11.6

/11.6

12

14

/11.6

11

13

1M

-13A1 /11.6

A2

11

-35K6 /11.6

10

L+

11

2

11

1

61

/11.6

-15A1

-7K5

-11F5

-27K6

-X2

-9K6

internal

target sign

9

-70K5

E.7

/11.6

/11.6

6

8

/92.8

5

/11.6

/92.8

4

7

/92.8

/9.2

/9.2

3

2

+CC_D-60N3

-13A1.1

+CC_D-60N3

13

type

22

lace connection

+CC_D-92S7

comment

number of terminals : 32

presentation

+CC_D-9S1

terminal number 1

wire connection

strip : -X12

item

21

terminal block

terminal

+CC_D-9S1

external

target sign

protection note according to ISO 16016 consider! free

0

0

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 13 31 sh.

cable internal

cable external

free

R. modification

terminal

date

14

lace connection

type

terminal number

item

date 25.07.2011

drawn ROS

check ROS

name standard origin replaced for

14 15 16 17 18

+CC_D-92H6 +CC_D-92H7 +CC_D-92H8 +CC_D-92S7 +CC_D-92H9

13

10

+CC_D-92H5

9

+CC_D-92H4

8

+CC_D-90H8

12

7

+CC_D-90H7

+CC_D-92H3

LT

6

+CC_D-90H6

11

LT

5

+CC_D-90H5

+CC_D-92H2

LT

4

+CC_D-90H4

LT

LT

LT

LT

LT

LT

LT

LT

LT

LT

LT

LT

3

LT

LT

LT

+CC_D-90H3

2

comment

number of terminals : 18

/92.7

/92.6

/92.6

/92.5

/92.4

/92.4

/92.3

/92.2

/90.8

/90.7

/90.6

/90.6

/90.5

/90.5

/90.4

/90.3

/90.3

/90.2

presentation

+CC_D-90H2

wire connection

strip : -X19

-27K6

-1K6

-28K4

-30K2

-30K6

-30K4

-42K5

-35K6

-25K2

-24K2

-27K2

-22K7

-20K1

-18K2

-17K2

-1K3

item

1

terminal block internal

target sign

12

14

14

14

14

14

34

14

24

24

34

24

34

24

24

14

terminal

+CC_D-90H1

external

target sign

protection note according to ISO 16016 consider! free

0

0

Control Cabinet Boiler terminalblock diagram / Klemmenplan 14

replaced by

=BCC+CC_M-X19

0-8100-100454-14 /3-32 =BCC

+CC_M

0-8100-100454-14-3 sheet 14 31 sh.

cable internal

cable internal

A2

A2

-17K2

-18K2

3 -X21

A1

23

24

+CC_MPE /17.6

/17.6

-17K7 /17.5

-17K2

1

2

5

+FOP1-X1

+FOP1-X1

+FOP1-X1

1

2

3

4

5

6 6

3 +FOP1-X1

5

4 +FOP1-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/17.5

/17.4

strip : -X20

terminal block

comment

number of terminals : 6

presentation

/17.4

-17K7

internal

item

item 1 -BCC_2120 M7G1,5

GNYE

cable external

free

+FOP1-X1

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

-X1

11

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 15

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X20

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 15 31

sh.

cable internal

A2

A2

-18K2

-20K1

15 -X11

A1

3

24

+CC_MPE /18.6

/18.6

-18K7 /18.5

-18K2

1

2

5

+FOP2-X1

+FOP2-X1

+FOP2-X1

1

2

3

4

5

6 6

3 +FOP2-X1

5

4 +FOP2-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/18.5

/18.4

strip : -X21

terminal block

comment

number of terminals : 6

presentation

/18.4

-18K7

internal

item

item 1 -BCC_2121 M7G1,5

GNYE

cable external

free

+FOP2-X1

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

-X20

11

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 16

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X21

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 16 31

sh.

cable internal

A2

A2

-20K1

-24K2

11 -5F2

A1

27

14

+CC_MPE /20.6

/20.6

-20K7 /20.6

-20K1

1

2

5

+FWP1-X1

+FWP1-X1

+FWP1-X1

1

2

3

4

5

6 6

3 +FWP1-X1

5

4 +FWP1-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/20.5

/20.4

strip : -X30

terminal block

comment

number of terminals : 6

presentation

/20.5

-20K7

internal

item

item 1 -BCC_2220 M7G1,5

GNYE

cable external

free

+FWP1-X1

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

-X1

11

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 17

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X30

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 17 31

sh.

cable internal

A2

11

-22K6 /21.8

/21.8

-22K1

-22K6 /21.7

/21.6

11

12

+BCCFWP2-X1

+BCCFWP2-X1

+BCCFWP2-X1

7

9

10

+BCCFWP2-X1

2

3

4

5

6 GNYE

cable external

0 -BCC_2222 M7G1,5

6

8 +BCCFWP2-X1

external

item

5

7 +BCCFWP2-X1

1

terminal

free

A1

14 -22K1

-22K8

6 +BCCFWP2-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/21.6

/21.4

strip : -X31

terminal block

comment

number of terminals : 7

presentation

/21.5

-22K7

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

A1

A1

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 18

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X31

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 18 31

sh.

cable internal

A2

A2

-24K2

-25K2

3 -X41

A1

41

24

+CC_MPE /24.6

/24.6

-24K7 /24.5

-24K2

1

2

5

+MGOP1-X1

+MGOP1-X1

+MGOP1-X1

1

2

3

4

5

6 6

3 +MGOP1-X1

5

4 +MGOP1-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/24.5

/24.4

strip : -X40

terminal block

comment

number of terminals : 6

presentation

/24.4

-24K7

internal

item

item 1 -BCC_2122 M7G1,5

GNYE

cable external

free

+MGOP1-X1

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

-X1

11

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 19

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X40

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 19 31

sh.

cable internal

A2

A2 -28K4

A1

-25K2

3

-25K7

+CC_MPE /25.6

/25.6

/25.5

-X40

-25K2

1

2

5

+MGOP2-X1

+MGOP2-X1

+MGOP2-X1

1

2

3

4

5

6 6

3 +MGOP2-X1

5

4 +MGOP2-X1

1

terminal number

4

type

3

lace connection

2

wire connection

/25.5

/25.4

strip : -X41

terminal block

comment

number of terminals : 6

presentation

/25.4

-25K7

internal

item

item 1 -BCC_2123 M7G1,5

GNYE

cable external

free

+MGOP2-X1

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

24

11

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 20

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X41

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 20 31

sh.

cable internal

4

6

0

free

N +CC_D-8M6

external

terminal

item

+CC_MPE

0

cable external

free

/8.6

-8B6

L +CC_D-8M6

1

terminal number

3

type

2

lace connection

PE

wire connection

+CC_D-8M6

strip : -X111

terminal block

comment

number of terminals : 3

/8.6

presentation

/8.6

-8B6

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 21

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X111

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 21 31

sh.

cable internal

0

free

/1.8

/1.8

/1.8

PE

PE

/1.8

PE

type

PE

lace connection

/1.8

wire connection

number of terminals : 5

comment strip : -XPE

terminal block

presentation

PE

+CC_MPE

internal

item

terminal number

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

item

cable external

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 22

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-XPE

0-8100-100454-14 /3-32

=BCC +CC_M

0-8100-100454-14-3

sheet 22 31

sh.

cable external

free

R. modification date date 25.07.2011

drawn ROS

check ROS

name standard origin

1 2 3 4

+CC_M-X1 +CC_M-X1 +CC_M-X1 +CC_M-X1

1 2 3 4 5 6 7 8 9 10 13 11

replaced for 12 14

20 6

+CC_M-X1

19

17

16

18

+CC_M-X1

+CC_M-X1

+CC_M-X1

+CC_M-X1

+CC_M-X1

5

11

Zündventile oil valves 13.01

ignition Zündtrafo valves

PE

15

14

13

12

11

10

9

8

7

6

5

12.17

Zünderbeheizung 06.01.22/06.49

igniter Heizungen 01.06.11 heater

Brennerheizung 01.06.10 heaters

Ölverteilerbeheizung burner heater

oil distributor heater

Flamme

Ölventile flame

oil Zündung valves

Notbetriebskasten ignition

emergency operation 08.02 box

Stellmotor06.01.xx/06.10 Verbundregler

servo 4 motor compound 13.03/13.09/13.11 regulator Ölventile

3

2

ignition transformer

/34.4

/54.8

/54.7

/54.3

/54.2

/54.6

/34.4

/34.4

/34.3

/34.2

/34.3

/61.5

/61.5

/38.6

/37.3

/37.2

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

internal

target sign

5

2

200

106

105

54

51

45

199

198

197

195

196

68

67

14

terminal

+CC_M-X1

10

+CC_M-X1

0 -BCC_2005 M16G1,5 +CC_M-X1

item 9

terminal 8

type

+CC_M-X1

lace connection

number of terminals : 16

comment

+CC_M-X1

terminal number 1

wire connection

strip : -X1.1

presentation

7

terminal block

item

+CC_M-X1

external

target sign

protection note according to ISO 16016 consider! free

0

15 GNYE

Control Cabinet Boiler terminalblock diagram / Klemmenplan 23

replaced by

=BCC+BW-X1.1

0-8100-100454-14 /3-32 =BCC

+BW

0-8100-100454-14-3 sheet 23 31 sh.

cable internal

cable external

free

R. modification

terminal number

date name standard

wire connection

lace connection

comment

type

date 25.07.2011

drawn ROS

check ROS

10 11

+CC_M-X2 +CC_M-X2

4 5 6 7 8 9

origin

12

14

+CC_M-X2

3

+CC_M-X2

13

+CC_M-X2

2

Luftkastentemperaturwächter oil pressure monitor 06.35

203

-X8

PE

replaced for

08.02

in Zündstellung 08.02

Endschalterin Verbungregler Zündstellung

Endschalter in purge Verbungregler position

232 /44.3

229

226

223

217

214

211

205

202

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

-X8

201

/47.4

/47.2

/46.2

/49.2

/48.2

/51.2

/50.2

/45.2

/44.2

-X8

internal

target sign

10 limit switch compound in ignitionregulator position 04.40

9 limit Endschalter switch compund Drehzerstäuber regulator 06.04.07

8limit switch rotary Öldruckwächter cup atomizer 04.09

7

windbox Schweröltemperaturwächter temperature monitor 06.36

16heavy 5 fuel Schweröltemperaturwächter oil temperature monitor 04.03

+CC_M-X2

1

6

15heavy 4 Verbrennungsluftdruckwächter fuel oil temperature monitor 04.04

+CC_M-X2

2 -BCC_3005 M12X1,5 8atomizing 2 air diff. pressure monitor

item Zerstäuberluftdifferenzdruckwächter 9 3 combustion air pressure monitor

terminal

+CC_M-X2

/44.2

presentation

+CC_M-X2

number of terminals : 11

strip : -X2.1

item

7

1

terminal block

terminal

+CC_M-X2

external

target sign

protection note according to ISO 16016 consider! free

0

10

Control Cabinet Boiler terminalblock diagram / Klemmenplan 24

replaced by

=BCC+BW-X2.1

0-8100-100454-14 /3-32 =BCC

+BW

0-8100-100454-14-3 sheet 24 31 sh.

cable internal

cable internal

506

501

502

503

-X8 /39.6

-X8

-X8 /39.5

/39.5

-X8 3

4

5

6

+CC_M-X3

+CC_M-X3

+CC_M-X3

+CC_M-X3

6

2 +CC_M-X3

5

-X8 /39.6

/39.6

14.02

1 +CC_M-X3

1

terminal number

4

type

Flammenfühler 1

lace connection

3

/39.6

wire connection

flame scanner 1

strip : -X3.1

terminal block

comment

number of terminals : 6

presentation

2

-X8

internal

item

1

2

3

4

5

S

external

terminal

target sign

protection note according to ISO 16016 consider!

target sign

terminal

504

505

0

free

item 6 -BCC_4001 M5X0,75SH

cable external

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 25

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+BW-X3.1

0-8100-100454-14 /3-32

=BCC +BW

0-8100-100454-14-3

sheet 25 31

sh.

cable internal

507

512 -X8 /40.6

-X8

-X8 /40.5

11

12

+CC_M-X3

+CC_M-X3

6

10 +CC_M-X3

2

3

4

5

S

cable external

6 -BCC_4002 M5X0,75SH

/40.5

9 +CC_M-X3

external

item

5

8 +CC_M-X3

1

terminal

free

508

509 -X8

-X8 /40.6

/40.6

14.02

7 +CC_M-X3

1

terminal number

4

type

Flammenfühler 2

lace connection

3

/40.6

wire connection

flame scanner 2

strip : -X3.2

terminal block

comment

number of terminals : 6

presentation

2

-X8

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

510

511

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 26

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+BW-X3.2

0-8100-100454-14 /3-32

=BCC +BW

0-8100-100454-14-3

sheet 26 31

sh.

cable internal

516

515

-X8 /62.3

-X8

1

2

3

4 +CC_MGND

-X8 /62.3

/62.3

08.02

Stellmotor Verbundregler

15

0 -BCC_4011 M3X0,75SH

SW

cable external

free

14

item

+CC_M-X3

external

terminal

+CC_M-X3

terminal number

3

/62.2

type

number of terminals : 4

lace connection

servo 1 motor compound regulator

wire connection

13

strip : -X3.3

terminal block

comment

+CC_M-X3

presentation

2

-X8

internal

item

target sign

protection note according to ISO 16016 consider!

target sign

terminal

514

513

0

free

R. modification

date

date

25.07.2011

drawn

ROS

check

ROS

name standard

terminalblock diagram / Klemmenplan 27

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+BW-X3.3

0-8100-100454-14 /3-32

=BCC +BW

0-8100-100454-14-3

sheet 27 31

sh.

cable external

free

R. modification

terminal

item

date date 25.07.2011

drawn ROS

check ROS

name standard origin replaced for

PE 1 2 PE

+BN-2Y2 +BN-2Y3 +BN-2Y3 +BN-2Y3

Control Cabinet Boiler

replaced by

1 2 PE L

+BN-3Y2 +BN-3Y5 +BN-3Y5 +BN-3Y5 +BN-5E1

=BCC+BW-X8

PE L

+BN-5E3 +BN-5E3 +BN-5E4

terminalblock diagram / Klemmenplan 28

12 22

-16K1 -16K1

0-8100-100454-14 /3-32 0-8100-100454-14-3

+BN-H1

Ölscharnierbeheizung

oil feed hinge heater

06.49

Ölblockbeheizung

oil block heater

06.01.22

ESV-Ventilbeheizung

ESV valve heater

01.06.11

Brennerheizung

burner heater

01.06.10

Ölverteilerbeheizung 2

oil distributor heater 2

01.06.10

Ölverteilerbeheizung 1

oil distributor heater 1

06.10

Hauptölentlastungsventil

main oil relief valve

06.01.02

Hauptölventil 2

main oil valve 2

06.01.01

Hauptölventil 1

08.02

Stellmotor Verbundregler

Flamme

199

31

0

=BCC

+BW sheet 28 sh.

04.04

PE Zerstäuberluftdifferenzdruckwächter 203

NO Differenzdruckwächter atomizing 202 air diff. pressure Zerstäuberluft monitor +BN-17F1

differential C 201 pressure monitor atomizing air +BN-17F1

200

Ölventile flame

Notbetriebskasten oil valves

emergency operation Zündung box

ignition

12.17

Zünderbeheizung 08.02

Stellmotor Verbundregler igniter heater 08.02

198

197

196

195

194

193

191

190

189

107

106

105

servo 68 motor Stellmotor compound Verbundregler regulator

servo 67 motor compound regulator

66

65

64

servo 63 motor compound regulator

62

61

60

59

58

57

56

55

54

53

52

51

50

49

48

47

46

45

31

30

29

22

21

20

19

18

+BN-17F1

+BN-H1

14 X1

+BN-S2

13

+BN-S1

+BN-S3

14

21

+BN-S

X2

21

+BN-S4

+BN-H1

13

+BN-9E2

+BN-S1

N PE

+BN-9E2

L

PE

+BN-6Y1-M

+BN-9E2

1

+BN-5E6

3

+BN-5E6

+BN-6Y1-M

N PE

+BN-5E6

+BN-6Y1-M

L

+BN-5E5

2

PE

+BN-5E5

+BN-6Y1-M

L N

+BN-5E5

N

N

+BN-5E3

PE

L

+BN-5E2

+BN-5E4

PE

+BN-5E2

+BN-5E4

L N

+BN-5E2

N

PE

+BN-3Y2

PE

2

+BN-3Y2

+BN-5E1

1

+BN-3Y1

main oil valve 1

06.01.01/06.01.02

16 17

Ölventile

oil valves

13.03/13.09/13.11

Zündventile

ignition valves

13.03/13.09/13.11

Zündventile

ignition valves

13.03/13.09/13.11

Zündventile

ignition valves

13.01

Zündtrafo

15

14

13

12

11

10

9

8

7

6

5

4

3

ignition transformer

5

/44.3

/44.2

/44.2

/34.4

/34.4

/34.4

/34.3

-X2.1

-X2.1

-X2.1

-X1.1

-X1.1

-X1.1

-X1.1

PE

2

1

PE

10

9

8

6

7 -X1.1

-X1.1 /34.3

A2 /34.2

A1 -16K1

-16K1 /34.5

16

-X

24

14

15

14

/34.5

-16K1

-16K1

-X1.1

-X1.1

-X1.1

4

/34.4

/34.5

/34.4

/54.8

/54.8

/54.7

/61.5

/61.5

/61.8

-X1.1

21

-16K1 /61.8

11

-16K1

13

12

11

3

2

1

/61.7

-X1.1

-X1.1

-X1.1

-X1.1

-X1.1

-X1.1

/61.7

/54.5

/54.5

/54.5

/54.4

/54.4

/54.4

/54.3

/54.3

/54.3

/54.2

/54.2

/54.2

/54.7

/54.7

/54.6

/54.6

/54.6

/54.6

/38.7

/38.7

/38.7

/38.4

/38.4

/38.4

/38.3

/38.3

/38.3

/38.6

/38.6

/38.6

/37.6

/37.5

/37.5

/37.5

/37.4

/37.4

/37.4

/37.3

/37.3

/37.3

/37.2

/37.2

internal

target sign

terminal

+BN-5E1

2 PE

+BN-3Y1

1

2

+BN-2Y2

+BN-3Y1

1

+BN-2Y2

V

PE

+BN-2Y1

U

2

+BN-2Y1

-3A1

1

+BN-2Y1

-3A1

PE

A2

type

+BN-2T1

lace connection

number of terminals : 108

comment

+BN-2T1

terminal number 2

wire connection

strip : -X8

presentation

A1

terminal block

item

+BN-2T1

external

target sign

protection note according to ISO 16016 consider! free

0

cable internal

cable external

free

R. modification

terminal block

wire connection

lace connection

date name standard

comment

type

date 25.07.2011

drawn ROS

check ROS

PE

origin

C

+BN-18F1

C

replaced for

Öldruckwächter

Control Cabinet Boiler

replaced by

/47.4 /47.4

+BN-6Y1-S4 limit switch compound C 231 regulator inin ignition purge position +BN-6Y1-S4

=BCC+BW-X8

terminalblock diagram / Klemmenplan 29

654 2 3 4

+CC_M-X0 +CC_M-X0 +CC_M-X0

1 2 3 GNYE

660

658

656

516 1

+CC_M-X0

0 -BCC_1004 M4G2,5 -SH

515

08.02

Stellmotor Verbundregler E

514

G +BN-6Y1-R1

Flammenfühler 2

flame scanner 2

+BN-6Y1-R1

511

510

512

+BN-40B2

servo 513 motor compound regulator 14.02

YE

+BN-40B2

509

14.02

B

WH

+BN-40B2

508

+BN-6Y1-R1

GN

+BN-40B2

Flammenfühler 1

flame scanner 1

08.02

in Zündstellung

Endschalter Verbungregler 08.02

inin purge Zündstellung position

-SH

BU RD

+BN-40B2

507

505 506

YE

+BN-40B1

504

503

502

501

233

-SH

GN WH

+BN-40B1

+BN-40B1 +BN-40B1

BU RD

+BN-40B1

PE

+BN-6Y1-S4

/2.3

/2.3

/2.2

/2.2

/62.3

/62.3

/62.3

+BN-2M2

+BN-2M2

+BN-2M2

+BN-2M2

-X3.3

-X3.3

-X3.3

PE

W

V

U

4

3

2

1

6 -X3.3

-X3.2 /62.2

1 /40.6

2 -X3.2

-X3.2 /40.6

3

-X3.2

4

5

6

1

2

3

4

5

10

9

/40.6

-X3.2

-X3.2

-X3.1

-X3.1

-X3.1

-X3.1

-X3.1

-X3.1

-X2.1

-X2.1

8

7

6

5

4

3

/40.6

/40.5

/40.5

/39.6

/39.6

/39.6

/39.6

/39.5

/39.5

/47.4

/47.2

Endschalter NO 229 limit Verbundregler switch compund in Zündstellung regulator

+BN-6Y1-S3

-X2.1

-X2.1

-X2.1

-X2.1

-X2.1

-X2.1

internal

target sign

terminal

Endschalter NO 232 limit Verbundregler switch Endschalter compound in Verbungregler Lüftstellung regulator

/47.2

+BN-6Y1-S3limit switch compound C 228 regulator in ignition position 04.40

/46.2 /46.3

PE

/46.2

/49.3

/49.2

/49.2

/48.3

/48.2

/48.2

/51.3

/51.2

/51.2

/50.3

/50.2

/50.2

227 Endschalter Drehzerstäuber

+BN-19S1

Endschalter NO 226 limit Drehzerstäuber switch rotary ausgeschwenkt cup atomizer

224

+BN-19S1

PE

oil pressure Druckwächter monitor Öl

pressure monitor 04.09 oil

limit switch C 225 rotary cup atomizer swung 06.04.07 out

+BN-18F4

223

222

218Luftkastentemperaturwächter

217 Temperaturwächter windbox temperature Luftkasten monitor

216 temperature monitor windbox 06.35

+BN-19S1

C

PE

+BN-18F3

NC

NC

+BN-18F3

+BN-18F4

C

+BN-18F3

+BN-18F4

PE

+BN-18F2

215 Schweröltemperaturwächter

NCheavy 214Temperaturwächter fuel oil temperatureSchweröl monitor

temperature monitor06.36 HFO

+BN-18F2

213

212 Schweröltemperaturwächter

PE

+BN-18F2

temperature monitor04.03 HFO

+BN-18F1

210

NOheavy 211Temperaturwächter fuel oil temperatureSchweröl monitor

+BN-18F1

/45.3

/45.2

/45.2

item

206 Verbrennungsluftdruckwächter

NO Differenzdruckwächter 205 combustion air pressure Zerstäuberluft monitor

item +BN-17F2

terminal

+BN-17F2

terminal number

differential C 204 pressure monitor atomizing air

number of terminals : 108

strip : -X8

presentation

+BN-17F2

external

target sign

protection note according to ISO 16016 consider! free

0

0

0-8100-100454-14 /3-32 =BCC

+BW

0-8100-100454-14-3 sheet 29 31 sh.

cable internal

cable external

free

R. modification date date 25.07.2011

drawn ROS

check ROS

name standard

6 7 8 9

+CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4

2 3 4 5 6 7 8 9

origin 10 11 12

replaced for 13 14 15 16 17 18 19 20

Control Cabinet Boiler

replaced by 21 22 23

27 28 29 30 31 32 33

+CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4

2 3 4 5 6 7 8 9

=BCC+ECR-X 10 11 12 13 14

terminalblock diagram / Klemmenplan 30 15 16 17 18 19 20 21 22 23

51 52 53 54 55 56 57

+CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4

2 3 4 5 6 7 8 9

0-8100-100454-14 /3-32

10 11

0-8100-100454-14-3

12 13 14 15 16

31

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

65

64

63

62

61

60

59

58

50

+CC_M-X4

1

+CC_M-X4

49

47

46

45

44

43

42

41

40

39

48

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

38

37

36

35

+CC_M-X4

24

+CC_M-X4

0 -BCC_6012 M18X1,5 +CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

34

26

+CC_M-X4

1

+CC_M-X4

25

23

22

24

+CC_M-X4

+CC_M-X4

21

20

19

18

17

16

15

14

13

12

11

+CC_M-X4

24

+CC_M-X4

0 -BCC_6011 M24X1,5 +CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

+CC_M-X4

10

5

+CC_M-X4

1

+CC_M-X4

4

+CC_M-X4

0 -BCC_6010 M24X1,5 3

item 2

terminal

+CC_M-X4

65

64

63

62

61

60

59

58

57

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

type number of terminals : 106

lace connection

+CC_M-X4

terminal number 1

wire connection strip : -X

comment

1

terminal block

/102.8

/102.8

/102.8

/102.7

/102.7

/102.7

/102.7

/102.6

/102.6

/102.6

/102.6

/102.5

/102.5

/102.4

/102.4

/102.4

/102.4

/102.3

/102.3

/102.2

/102.2

/102.2

/102.2

/101.8

/101.8

/101.7

/101.7

/101.6

/101.6

/101.6

/101.6

/101.5

/101.5

/101.5

/101.5

/101.4

/101.4

/101.3

/101.3

/101.3

/101.3

/101.2

/101.2

/100.8

/100.8

/100.7

/100.7

/100.6

/100.6

/100.6

/100.6

/100.5

/100.5

/100.4

/100.4

/100.4

/100.4

/100.3

/100.3

/100.3

/100.3

/100.2

/100.2

/100.2

/100.2

presentation

+CC_M-X4

external

target sign

protection note according to ISO 16016 consider!

internal

target sign

free

terminal

item

17

=BCC

+ECR sheet 30 sh.

cable internal

cable external

free

R. modification

18 -BCC_6012 M18X1,5

0 -BCC_6013 M18X1,5

date date 25.07.2011

drawn ROS

check ROS

name standard 1

origin 2 3 4 5 6 7 8 9 10 11

0 -BCC_6014 M18X1,5

replaced for 12 13 14 15 16 17 1

Control Cabinet Boiler

replaced by 2 3 4 5 6 7 8 9 10 11 12

=BCC+ECR-X 13 14 15 16 17

77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101

+CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4 +CC_M-X4

4

76

+CC_M-X4

+CC_M-X6

75

+CC_M-X4

2

74

+CC_M-X4

3

73

+CC_M-X4

+CC_M-X6

72

+CC_M-X4

+CC_M-X6

71

+CC_M-X4

1

70

+CC_M-X4

102

69

+CC_M-X4

+CC_M-X6

2 -BCC_6001 M5X0,75SH +CC_M-X4

68

item 67

terminal

+CC_M-X4

terminalblock diagram / Klemmenplan 31

-

-

+

+

102

101

100

99

98

97

96

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

79

78

77

76

75

74

73

72

71

70

69

68

67

type Kesselwasserniveau

boilerDampfdruck water level

steam pressure

number of terminals : 106

lace connection

+CC_M-X4

terminal number 66

wire connection strip : -X

comment

66

terminal block

/70.7

/64.5

/70.6

/64.5

/104.6

/104.6

/104.6

/104.6

/104.5

/104.5

/104.5

/104.5

/104.4

/104.4

/104.3

/104.3

/104.3

/104.3

/104.2

/104.2

/104.1

/104.1

/103.6

/103.6

/103.6

/103.6

/103.5

/103.5

/103.5

/103.5

/103.4

/103.4

/103.3

/103.3

/103.3

/103.3

/103.2

/103.2

/103.2

/103.2

/102.8

presentation

+CC_M-X4

external

target sign

protection note according to ISO 16016 consider!

internal

target sign

free

terminal

item

18 1 3 2 4

18 18

0-8100-100454-14 /3-32 =BCC

+ECR

0-8100-100454-14-3 sheet 31 31 sh.

cable internal

R. modification date name standard date 07.12.2011

drawn ROS

check ROS

origin replaced for

M M M

3~ 3~ 3~ 3~ 3~ 1~

Control Cabinet Boiler

replaced by

M

3~ 3~

=BCC+CC_M-X0

terminal connection diagram / Anschlussplan 1

+MSB2-X

+CC_D

-1Q5

+MSB1-X

+CC_D

2PE

1PE

M -1Q2

+MGOP2

-3M7

+MGOP1

PE

L3

L2

L1

M

-3M5

660

658

656

654

M

+BN-5E3-X

+FW

-5M2

+FWP1

-4M2

+FOP2

-3M3

+FOP1

-3M2

+BN

-2M5

+F

-2M3

+BW-X8

GNYE

PE

GNYE

PE

5

33

3

23

1

13

5

33

3

23

1

GNYE

H07Z-K

H07Z-K

H07Z-K

GNYE

H07Z-K

H07Z-K

H07Z-K

3

W

13

2

GNYE

PE

V

3

W

1

2

V

U

1

GNYE

3

M4G35

-BCC_1001

M4G25

-BCC_1000

M4G1,5

-BCC_1009

M4G1,5

-BCC_1008

M4G4

GNYE

H07Z-K

H07Z-K

H07Z-K

GNYE

H07Z-K

H07Z-K

H07Z-K

GNYE

3

2

1

GNYE

3

2

1

GNYE

3

2

2

GNYE

2

1

GNYE

3

2

1

GNYE

3

2

1

GNYE

3

2

1

GNYE

3

2

1

GNYE

3

2

1

-BCC_1012

M3G1,5

-BCC_2020

M4G2,5

-BCC_1006

M4G1,5

-BCC_1011

M4G1,5

-BCC_1010

M4G4

-BCC_1003

M4G1,5

-BCC_1005

1

GNYE

3

1

2

U

V

1

3

W

U

2

V

GNYE

PE 1

3

W

U

2

V

GNYE

PE 1

3

W

U

2

V

GNYE

PE 1

3

W

U

2

GNYE

PE

V

3

W

1

2

V

U

1

U

GNYE

M4G2,5

2

2 3

1

1

-BCC_1004

protection note according to ISO 16016 consider!

M

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 1 19 sh.

/2.6

9

/3.2

13

/3.4

17

/4.2

21

/3.7

36

-2PE

-2L3

-2L2

-2L1

-1PE

-1L3

-1L2

/1.5

/1.5

/1.5

/1.5

/1.2

/1.2

/1.2

/1.2

/3.8

39

-1L1

/3.7

38

/3.7

/3.6

35

37

/3.5

34

/3.5

/3.5

32 33

/5.4

/5.4

/5.4

31

30

29

/5.4

/5.2

27 28

/5.2

26

/5.2

/4.2

24 25

/4.2

23

/4.2

/3.4

20

22

/3.4

19

/3.4

/3.2

16

18

/3.2

15

/3.2

/2.6

12

14

/2.6

11

/2.6

/2.4

8

10

/2.4

7

/2.4

/2.4 6

/2.3 5

/2.3

/2.2

/2.2

4

3

2

1

Klemmen-Anzahl : 47

-X0

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 2

replaced by

=BCC+CC_M-X1

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 2 19 sh.

06.01.22/06.49

Heizungen

heaters

01.06.11

Brennerheizung

burner heater

+BW-X1.1

+BN

-5E3

-X1

08.02

Stellmotor Verbundregler

servo motor compound regulator

06.01.xx/06.10

Ölventile

oil valves

13.03/13.09/13.11

Zündventile

ignition valves

13.01

Zündtrafo

ignition transformer

Flamme

flame

Ölventile

oil valves

Zündung

ignition

Notbetriebskasten

emergency operation box

+BW-X1.1

13

12

12

5

4

3

2

1

PE

10

9

8

7

6

2 3 GNYE

02 05 PE

12

11

1

01

H07Z-K

5

4

3

2

1

GNYE

10

9

8

7

6

M16G1,5

-BCC_2005

M4G1,5

-BCC_2022

M16G1,5

-BCC_2005

protection note according to ISO 16016 consider!

12

11

GNYE

3

2

1

H07Z-K

5

4

3

2

1

GNYE

10

9

8

7

6

/5.5

17

/54.3

/54.2

15 16

/5.5

/5.5

/5.5

/61.5

/61.5

/38.6

/37.3

/37.2

/34.4

/34.4

/34.4

/34.3

/34.2

/34.3

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Klemmen-Anzahl : 42

-X1

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 3

replaced by

=BCC+CC_M-X1

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 3 19 sh.

PE

Öltrübungsüberwachung

+GO 006

-23F7

NC

N

oil turbidity monitoring

3

8

1 2

13 14

3

4

2

1

GNYE

PE

GNYE

2

2

L

CO 011

2

14

2

+F-77A2

FW 007

Leitfähigkeitsüberwachung

conductivity monitoring

+F-76A3

1

13

1

PE

Kesselwasserstandsmeßumformer

2

14

1

1

13

15

14

1

5

boiler water level transmitter

BO 021

3

15

14

11

+BO-68B2

+FW005

-19F7

+FO 006

-16F7

12.17

Zünderbeheizung

igniter heater

01.06.10

Ölverteilerbeheizung

oil distributor heater

+BW-X1.1

13

M2X1,5

-BCC_3018

M4G1,5

-BCC_2008

M4G1,5

-BCC_2009

M3G1,5

-BCC_2006

M2X1,5

-BCC_3016

M2X1,5

-BCC_3014

M16G1,5

-BCC_2005

protection note according to ISO 16016 consider!

2

1

3

4

2

1

3

GNYE

2

1

GNYE

2

1

2

1

2

1

15

14

13

/5.6

22

/77.3

40

42

/23.7

/23.7

/77.3

39

41

/77.3

/77.2 38

37

/77.2

/76.5

35

36

/76.5

/76.5

/76.4

34

33

32

/68.2

/68.2

29

/68.2

/19.8

28

31

/19.8

27

30

/19.7

/19.7

/16.7

26

25

24

/16.7

/5.6

21

23

/54.8

/54.7

/54.6

20

19

18

Klemmen-Anzahl : 42

-X1

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 4

replaced by

=BCC+CC_M-X2

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 4 19 sh.

BO 041

Rauchgastemperaturwächter

flue gas temperature monitor

+BO-53F2

BO 034

Dampfdruckwächter

steam pressure monitor

+BO-52F2

06.35

Schweröltemperaturwächter

heavy fuel oil temperature monitor

06.36

Schweröltemperaturwächter

heavy fuel oil temperature monitor

06.04.07

Öldruckwächter

oil pressure monitor

04.09

Luftkastentemperaturwächter

windbox temperature monitor

08.02

in Zündstellung

Endschalter Verbungregler

in purge position

limit switch compound regulator

08.02

in Zündstellung

Endschalter Verbungregler

in ignition position

limit switch compund regulator

04.40

Endschalter Drehzerstäuber

limit switch rotary cup atomizer

04.03

Verbrennungsluftdruckwächter

combustion air pressure monitor

04.04

Zerstäuberluftdifferenzdruckwächter

atomizing air diff. pressure monitor

+BW-X2.1

Fluchtweg

Not-Stop 2

escape route

emergency stop 2

+F-9S3

Fluchtweg

Not-Stop 1

escape route

emergency stop 1

+F-9S2

5

4

7

6

10

9

8

3

2

1

2

NC

2

2

NC PE

1

C

PE

1

C NC

5

4

7

6

10

9

8

3

2

1

2

NC PE

1

C

PE

1

C

M2X1,5

-BCC_3007

M2X1,5

-BCC_3006

M12x1,5

-BCC_3005

M2X1,5

-BCC_3002

M2X1,5

-BCC_3001

protection note according to ISO 16016 consider!

2

1

2

1

5

4

7

6

10

9

8

3

2

1

2

1

2

1

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

/53.2

/53.2

/52.2

/52.2

/51.2

/50.2

/49.2

/48.2

/47.4

/47.2

/46.2

/45.2

/44.2

/44.2

/9.3

/9.3

/9.3

/9.3

/9.2

/9.2

Klemmen-Anzahl : 40

-X2

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 5

replaced by

=BCC+CC_M-X2

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 5 19 sh.

to MGO

limit switch 3 way -valve

+F-59S6

to MGO

limit switch 3 way -valve

+F-59S5

toHFO

limit switch 3 way -valve

+F-59S3

to HFO

limit switch 3 way -valve

+F-59S2

BN 010

Druckregler in Leichtölstellung

Endschalter 3-Wege-Ventil

pressure controller in light fuel oil position

limit switch 3-way-valve

+F-57S3

FO 002

Zuleitung in Leichtölstellung

Endschalter 3-Wege-Ventil

pre line in light fuel oil position

limit switch 3-way-valve

+F-57S2

BN 010

Druckregler in Schwerölstellung

Endschalter 3-Wege-Ventil

pressure controller in heavy fuel oil position

limit switch 3-way-valve

+F-56S3

FO 002

Zuleitung in Schwerölstellung

Endschalter 3-Wege-Ventil

pre line in heavy fuel oil position

limit switch 3-way-valve

+F-56S2

FO 003

Rückleitung in Pumpenstellung

Endschalter 3-Wege-Ventil

return line in pump position

limit switch 3-way-valve

+F-55S3

C

2

NO

4

NO

4

2

2

NO

4

NO

4 PE

3

C NO

PE

3

C

PE

1

C

PE

1

C NO

PE

3

C NO

PE

3

C

PE

1

2

C

PE

NO

1

4

NO PE

3

C

M4x1,5

-BCC_3021

M4x1,5

-BCC_3020

M4x1,5

-BCC_3021

M4x1,5

-BCC_3020

M4x1,5

-BCC_3012

M4x1,5

-BCC_3010

M4x1,5

-BCC_3012

M4x1,5

-BCC_3010

M4x1,5

Rückleitung in Tankstellung FO 003

-BCC_3008

PE

2

NO

Endschalter 3-Wege-Ventil

return line in tank position

limit switch 3-way-valve

+F-55S2

1

C

protection note according to ISO 16016 consider!

4

3

4

3

2

1

2

1

4

3

4

3

2

1

2

1

4

3

2

1

42

41

40

39

38

37

36

35

32

31

30

29

28

27

26

25

24

/59.7

/59.6

/59.5

/59.5

/59.3

/59.3

/59.2

/59.2

/57.4

/57.3

/57.2

/57.2

/56.4

/56.3

/56.2

/56.2

/55.4

/55.3

/55.2

22

23

/55.2

21

Klemmen-Anzahl : 40

-X2

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 6

replaced by

=BCC+CC_M-X3

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 6 19 sh.

08.02

Stellmotor Verbundregler

servo motor compound regulator

+BW-X3.3

14.02

Flammenfühler 2

flame scanner 2

+BW-X3.2

14.02

Flammenfühler 1

flame scanner 1

+BW-X3.1

2

1

6

5

4

3

2

1

6

5

4

3

2

1

2

M3x0,75SH 2

1

1

-BCC_4011

S

5

5

S

4

3

4

3

M5x0,75SH

1

1

-BCC_4002

S

S

2

5

5

2

4

M5x0,75SH

-BCC_4001

3

2

1

4

3

2

1

protection note according to ISO 16016 consider!

14

13

12

11

10

9

8

7

6

5

4

3

2

1

/62.3

/62.2

/40.6

/40.5

/40.5

/40.6

/40.6

/40.6

/39.6

/39.5

/39.5

/39.6

/39.6

/39.6

Klemmen-Anzahl : 30

-X3

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 7

replaced by

=BCC+CC_M-X3

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 7 19 sh.

1 GND 2 3

+BO-69B3 boiler water level electrode Kesselwasserstandselektrode BO 022

BO 021

Kesselwasserstandsmeßumformer

1-

4

3

2

1

S

2

M4x0,75SH

-BCC_4003

M2x0,75SH

4

3

2

1

S

2

1

boiler water level transmitter

-BCC_4005

1

+BO-68B2

M2x0,75SH

-BCC_4000

3

2

1

2

1

M3x0,75SH

-BCC_4011

BO 033

2+

-

steam pressure transmitter Dampfdruckmeßumformer

+

3

+BO-64B2

+BW-X3.3

3

protection note according to ISO 16016 consider!

/64.3

19

/68.4 /68.4 /68.4 /69.3

23 24 25 26

/69.3 /69.4 /69.4

28 29 30

/69.3

/68.4

22

27

/68.4

21

/68.3

/64.3

20

/64.3 18

/64.2

/62.3

17

16

15

Klemmen-Anzahl : 30

-X3

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 8

replaced by

=BCC+CC_M-X4

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 8 19 sh.

+ECR-X

73

72

71

70

69

68

67

66

65

64

63

62

61

60

59

58

57

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

12

12

19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12

19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12

19 20 21 22 23 24 1 2 3 4 5 6 7 8 9

19 20 21 22 23 24 1 2 3 4 5 6 7 8 9

16 17 18 1

16 17 18 1

7

7

5 6

M18x1,5

5

4

6

-BCC_6013 4

3

15

15

3

14

14

2

13

13

2

12

11 12

11

10

18

18

M18x1,5

17

17

-BCC_6012

16

16

10

15

14 15

14

13

18

18

M24x1,5

17

17

13

16

16

-BCC_6011

15

14

15

14

M24x1,5

11

11

13

10

10

13

9

9

8

8

5

5

7

4

4

7

3

3

6

2

2

6

1

1

-BCC_6010

protection note according to ISO 16016 consider!

73

72

71

70

69

68

67

66

65

64

63

62

61

60

59

58

57

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

/103.3

/103.3

/103.3

/103.2

/103.2

/103.2

/103.2

/102.8

/102.8

/102.8

/102.8

/102.7

/102.7

/102.7

/102.7

/102.6

/102.6

/102.6

/102.6

/102.5

/102.5

/102.4

/102.4

/102.4

/102.4

/102.3

/102.3

/102.2

/102.2

/102.2

/102.2

/101.8

/101.8

/101.7

/101.7

/101.6

/101.6

/101.6

/101.6

/101.5

/101.5

/101.5

/101.5

/101.4

/101.4

/101.3

/101.3

/101.3

/101.3

/101.2

/101.2

/100.8

/100.8

/100.7

/100.7

/100.6

/100.6

/100.6

/100.6

/100.5

/100.5

/100.4

/100.4

/100.4

/100.4

/100.3

/100.3

/100.3

/100.3

/100.2

/100.2

/100.2

/100.2

Klemmen-Anzahl : 102

-X4

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 9

replaced by

=BCC+CC_M-X4

0-8100-100454-14 /3-32 =BCC.

+CC_M

0-8100-100454-14-3 sheet 9 19 sh.

+ECR-X

102

101

100

99

98

97

96

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

79

78

77

76

75

74

-BCC_6014

8 9

8 9

12 13 14 15 16 17 18

13 14 15 16 17 18

11

12

11

M18x1,5

7

7

10

6

6

10

5

5

2

2

4

1

1

4

18

18

3

17

17

3

16

15

14

16

15

M18x1,5

12

12

14

11

11

13

10

10

-BCC_6013

9

9

13

8

8

protection note according to ISO 16016 consider!

102

101

100

99

98

97

96

95

94

93

92

91

90

89

88

87

86

85

84

83

82

81

80

79

78

77

76

75

74

/104.6

/104.6

/104.6

/104.6

/104.5

/104.5

/104.5

/104.5

/104.4

/104.4

/104.3

/104.3

/104.3

/104.3

/104.2

/104.2

/104.1

/104.1

/103.6

/103.6

/103.6

/103.6

/103.5

/103.5

/103.5

/103.5

/103.4

/103.4

/103.3

Klemmen-Anzahl : 102

-X4

date

/70.7 4

4

/70.6

4 boiler water level

07.12.2011

drawn

ROS

check

ROS

name standard

Kesselwasserniveau

+

-

3

M5x0,75SH

2 Dampfdruck

steam pressure

+ECR-X

+

-

1

-BCC_6001

3

3

/64.5 2

2

/64.5 1

Klemmen-Anzahl : 4

1

-X6 protection note according to ISO 16016 consider! R. modification

date

terminal connection diagram / Anschlussplan 10

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X6

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 10 19

sh.

/17.6 6 GNYE

/17.6 5

/17.5 4

5

4

GNYE 6

5

5

M7G1,5

4

-BCC_2120 1

3

4

+FOP1-X1

2

/17.4

/17.5 3

3 3

2

/17.4

2 2

Klemmen-Anzahl : 6

1 1 1

-X20 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 11

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X20

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 11 19

sh.

/18.6 6 GNYE

/18.6 5

/18.5 4

5

4

GNYE 6

5

5

M7G1,5

4

-BCC_2121 1

3

4

+FOP2-X1

2

/18.4

/18.5 3

3 3

2

/18.4

2 2

Klemmen-Anzahl : 6

1 1 1

-X21 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 12

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X21

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 12 19

sh.

/20.6 6 GNYE

/20.6 5

/20.6 4

5

4

GNYE 6

5

5

M7G1,5

4

-BCC_2220 1

3

4

+FWP1-X1

2

/20.5

/20.5 3

3 3

2

/20.4

2 2

Klemmen-Anzahl : 6

1 1 1

-X30 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 13

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X30

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 13 19

sh.

/21.8

/21.8 7

6

GNYE GNYE 12

11

/21.6

/21.7

6

6

5

4

5 M7G1,5 5

9

10

/21.5

/21.6

-BCC_2222 4

4

3

3

8

+BCCFWP2-X1

7

3

2

/21.4 1

2 2

Klemmen-Anzahl : 7

6

1 1

-X31 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 14

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X31

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 14 19

sh.

/24.6 6 GNYE

/24.6 5

/24.5 4

5

4

GNYE 6

5

5

M7G1,5

4

-BCC_2122 1

3

4

+MGOP1-X1

2

/24.4

/24.5 3

3 3

2

/24.4

2 2

Klemmen-Anzahl : 6

1 1 1

-X40 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 15

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X40

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 15 19

sh.

/25.6 6 GNYE GNYE 6

/25.5

/25.6 5

4

5 M7G1,5 5 5

2

/25.4

/25.5

-BCC_2123 4

4

3

3

1

+MGOP2-X1

3

3

2

/25.4 1

2 2

Klemmen-Anzahl : 6

4

1 1

-X41 protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 16

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-X41

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 16 19

sh.

/1.8

/1.8

/1.8

/1.8

/1.8

PE

PE

PE

PE

PE

Klemmen-Anzahl : 5

-XPE protection note according to ISO 16016 consider! R. modification

date

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 17

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+CC_M-XPE

0-8100-100454-14 /3-32

=BCC. +CC_M

0-8100-100454-14-3

sheet 17 19

sh.

/4.5 -1PE 1PE

GNYE

/4.4

/4.5

GNYE

-1L3

-1L2

3

M4G4

3

1L2

GNYE PE

2

3 W

1

2 V

1L1

1L3

/4.4

-BCC_1002

2

/4.6

-1L1

4

1

/4.6

1 U

M4G2,5

GNYE

/4.6

3

3

2

/4.6 1

-BCC_1007

2

Klemmen-Anzahl : 8

1 date

+BCCFWP2+MSB2-X

-4M3

3~ +BCCFWP2+FWP2

-X0 protection note according to ISO 16016 consider! R. modification

M

date

07.12.2011

drawn

ROS

check

ROS

name standard

terminal connection diagram / Anschlussplan 18

Control Cabinet Boiler origin

replaced for

replaced by

=BCC+BCCFWP2-X0

0-8100-100454-14 /3-32

=BCC. +BCCFWP2

0-8100-100454-14-3

sheet 18 19

sh.

R. modification date date 07.12.2011

drawn ROS

check ROS

name standard

Control Cabinet Boiler

origin replaced for

terminal connection diagram / Anschlussplan 19

replaced by

=BCC+BCCFWP2-X1

0-8100-100454-14 /3-32 =BCC.

+BCCFWP2

0-8100-100454-14-3 sheet 19 19 sh.

+FWP2-X1

+CC_M-X31

+FWP2-X1

6

7

6

5

4

3

2

1

5

2

1

3

4

GNYE

GNYE

6

5

M7G1,5

-BCC_2221

M7G1,5

3

3

GNYE

GNYE

6

5

4

2

2

4

1

5

4

3

1

-BCC_2222

M7G1,5

4 5

-BCC_2221

2

2 3

1

1

protection note according to ISO 16016 consider!

13

12

11

10

9

8

7

6

5

4

3

2

1

/21.4

/21.8

/21.8

/21.7

/21.6

/21.6

/21.5

/21.4

/21.3

/21.2

/21.2

/21.3

/21.3

Klemmen-Anzahl : 13

-X1

1

2

3

4

5

6

Cabinet 1800 x 1600 x 400

7

8

Schaltschrankfarbe: Color of control cabinet:

TS 8884.500

A

A

Munsell 7,5 BG 7/2 1600

56

SAACKE SAACKE

SAACKE SAACKE

SAACKE SAACKE

58 B

99

Feed water pump 2

E

20

21

22

23

26

30

31

32

33

36

MSB 2 2

1

24

34

3

4

5

6

7

8

9

10

11

12

13

14

15

16

C

25

35

46

48

49 60

60

57

57 47

45

D

all lines without indication of cross section are

D

54

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

50

C

B

99

98

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 1

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 1

0-8100-100454-14-3

front view / Frontansicht 5

=BCC

6

7

19 8

sh.

F

1

2

No.

Name

Hole

3

Color

4

Equipment

Function

No.

0 A

2P5

Z

2

30P5

P

3

92H9

R

4

92H7

R

5

36S5

R

9S8

R

C

E

51

Hour meter

rotary cup

52

red

Lamp

alarm

53

green

Lamp

preheater on

54

black

Push Button

reset burner

55

black

Push Button

release / reset

56

Push Button

lamptest

57

burner in operation

58

7

92S7

R

black

8

92H3

R

green

Lamp

9

92H2

R

yellow

Lamp

burner stand by

59

10

92H4

R

green

Lamp

rotary cup on

60

11

92H5

R

green

12

92H6

R

13

35S5

R

14

30S2

15

42S6

16

39S2

green

Lamp

ignition oil pump on

Lamp

combustion air fan on

Switch

1 firing - 0 - 2 emergency mode

R

Switch

combustion air fan

R

Switch

Equipment

Q

Function load controller

Controller

A

13A5

X

Monitoring

Alarm monitoring Aluminium plate SAACKE Type

Resopal

plate 25x100mm

label: Resopal

BOILER CONTROL CABINET CS 010 Voltage 440V / 60Hz

plate 25x100mm

FEED WATER PUMP 2 CONTROL BOX CS 010

Warning: 2 FEEDING CIRCUITS. B

R

Switch

64

release load control

65

preselection flame scanner

66

68 69

20

90H4

R

green

Lamp

feed water pump 1 on

21

90H5

R

green

Lamp

feed water pump 2 on

71 72

70

22

90H2

R

green

Lamp

fuel oil pump 1 on

23

90H3

R

green

Lamp

fuel oil pump 2 on

73

24

90H7

R

green

Lamp

MGO pump 1 on

74

25

90H8

R

green

Lamp

MGO pump 2 on

75

chemical dosing pump on

76

90H6

R

green

Lamp

27

77

28

78 73

29

79 19S3

R

Switch

feed water pump 1

80

Switch

feed water pump 2

81

fuel oil Pump 1

82

31

19S4

R

32

16S3

R

33

16S4

R

Switch

fuel oil Pump2

83

34

23S3

R

Switch

MGO Pump 1

84

35

23S4

R

Switch

MGO Pump2

85

Switch

chemical dosing pump

86

27S2

Switch

R

37

87

38

88

39

89

40

90

41

91

42

92

43

93

44 45

60N3

Color

8

BEFORE OPENING CABINET

67

36

Hole

7

SWITCH OFF BOTH SUPPLIES

18

30

6

label:

17

26

all lines without indication of cross section are

D

current monitoring

combustion air fan

19

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

50

1

6

5

C

D

E

94 1Q2

46

90H1

47

1Q5

R

white

Main Switch

main switch

Lamp

1. control voltage selected

Main Switch

48

92H8

R

49

9S1

R

white

main switch

Lamp

1

95 96

2

97

2. control voltage selected

Push Button

boiler stop

98

8M6

fan cabinet

99

8M6

outlet strainer cabinet

F

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 2

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 2

0-8100-100454-14-3

legend door 2 / Legende Tür 2 5

=BCC

6

7

19 8

sh.

1

2

3

4

5

6

7

8

A

A

400

1600

B

D

all lines without indication of cross section are

D

C

1800

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

E 100

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 3

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 3

0-8100-100454-14-3

control cabinet / Schaltschrank 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

Control cabinet bottom A

A

Schaltschrankboden

(dimension without side walls) (for cabinets in 1200mm width) 1135

(dimension without side walls) B

B 797

E

~ 140

C

expanded rubber 240

275

for sealing cable entry

bottom plate 2

cable entry

140 ~

bottom plate 3

Ф 16

D

78,5

640

all lines without indication of cross section are

D

bottom plate 1

405

C

back plane

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

675

78,5

E

bottom plate 1+3 are fixed bottom plate 2 is adjustable

scale : 1:5 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 4

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 4

0-8100-100454-14-3

control cabinet / Schaltschrank 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

Kupferschiene

5

6

7

8

für Erdungsanschlüsse

A

A

Copper rail to fix earth potential connections

B

C

D

all lines without indication of cross section are

D

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 5

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 5

0-8100-100454-14-3

base control cabinet / Sockel Schaltschrank 5

=BCC

6

7

19 8

sh.

1

2

3

4

5

A Bohrung / Bore hole: R

6

7

M =

Name plate of control cabinet

N =

Name plate of control cabinet

8

A

Bohrung / Bore hole: P

12,7

3

22,5

45

E

Bohrung / Bore hole: X

Bohrung / Bore hole: D

Bohrung / Bore hole: D1

C

142

Bohrung / Bore hole: Q

68

92

199

177

124

D Bohrung / Bore hole: Y

Bohrung / Bore hole: W

Bohrung / Bore hole: S

+0,8

177²

22,5

185²

all lines without indication of cross section are

D

B

92

C

Bohrung / Bore hole: Z

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

45

+0,3

22,2

E

φ

4,5

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 8

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 8

0-8100-100454-14-3

bore holes / Bohrungen 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

Sockel TS / socket TS Stahlblech / sheet steel

A

A

32,5

Sockel / socket 100mm hoch / high

100

62,5

18 x 14

80

17,5

62,5

30

47,5

14 92,5

B

B

C

E

T4

T3

T2

T1

C

Sockel-Element, vorn/hinten socket-element, front/behind

Sockel-Element, seitlich

mm

mm

socket-element, sidewise

B4

B1

B2

B3

B4

T1

T2

T3

T4

B3

-

-

-

-

269

235

175

144

B2

400

335

275

215

369

335

275

244

B1

500

435

375

315

469

435

375

344

600

535

475

415

569

535

475

444

800

735

675

615

769

735

675

644

850

785

725

665

-

-

-

-

1000

935

875

815

869

835

775

744

1100

1035

975

915

-

-

-

-

1200

1135

1075

1015

969

935

875

844

Für die Verschraubung am Boden können alle Bohrungen (B2-B4 / T2-T4) genutzt werden.

all lines without indication of cross section are

D

30

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

15 x 10

D

For floor connection all holes (B2-B4 / T2-T4) could be used

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 9

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 9

0-8100-100454-14-3

base control cabinet / Sockel Schaltschrank 5

=BCC

6

7

19 8

sh.

4

5

6

105

0 70

140

210

210

105 140

70

0

70

140

A

40

40

210

A

8

800

0

105

800

7

140

3

70

2

0

1

0 155

M

N

D1

330

D1

B

B

Q

X

E

500

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R

R R

R

R

R

R

R

R

R

R

R

R

R

580 660 740

C

820

R

900

R

R

980

200

1060 1140

M

M

600

D

D 250

all lines without indication of cross section are

D

P

1800

C

Z

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

400

E 0

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

23.07.2011

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 10

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 10

0-8100-100454-14-3

bore holes / Bohrungen 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

B

B

internal

-43K2 -42K4

E

-22K7

-8B6

-41K5 -39K3

-38K2

-7Q2

-22K6

-X1

-36K7 -5Q4

-36K3 -X111

-42K6

-32K2 -27K8

-9K7

-42K3

-27K6

-35K2

-27K5

-9K6

-8F2

-27K4

-7F5

-3Q7

-25K2

-3Q5

-24K2

-27K2

-27K3

-7F4

-20K2

-42K5

-27K7

-8F3

-4Q2

external

-32K6

-8F5 -8F4

-28K4

-35K6

-34K6

-8F6

C

-7T2

-5F2

-25K8

-3Q3

-18K2

-3Q2

-17K2

-25K7 -24K8

-77K4

-24K7

-76K5

-23K7

-74K7

-22K3

-2T5

-74K6

-22K2

D

-1F6

-20K7 -2Q5

-20K3

-1F3

-30K2

-19K7 -18K8

-1K6

-18K7

-X11

-17K8

-69K5 -X10

-2Q3

-30K6

-2Q2

-30K4

-17K7 -16K7

-33K4

-12K2

-1K3

-X0

-9K8

-9K5

all lines without indication of cross section are

D

-42K3

-34K7

698

C

-22K8

-37K7

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

-40K3

-7K5

E

1699

scale : 1:5 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 11

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 11

0-8100-100454-14-3

mounting plate / Montageplatte 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

1698

-X20

-X31

-X40

-X41

-40A3 -39A3

-47K6

-73A2

XPE -70A2

C -X4

-69A2

698

-15A1 -59K7

-14A1.1

internal

-57K6

-56K6

-63K5

-50K6

-63K4

-61K4

-13A1.1

-48K6

-13A1

external

-61K3

-10A3

-61K2

-47K5

H07Z-K 1,5mm²

D

-63K3

-49K6

-59K4 -58K6

-46K6

-10A2

-X3

-63K6

-52K6

-X19

-X6

-53K6

-11G2

-X2

-14A1

55K6 -45K4

-55K5

-X12

-8X8

-46K8

-44K4

all lines without indication of cross section are

D

spare place PLC

-51K6

-151.1

protection note according to ISO 16016 consider!

-11F4

C

-70K5

-12A3

-11F5

-X21

B

-X30

B

E

E

scale : 1:5

100

scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 11.1

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 11.1

0-8100-100454-14-3

mounting plate / Montageplatte 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

B

B

C

C

S-Nr.: 0-8100-100454-14 /3-32 A-Nr.: 100454 HN: 0108216 Baujahr: 2012 UN

= 440V

f = 60 Hz

IN

=

PN = D

SAACKE BREMEN GERMANY

all lines without indication of cross section are

D

Typ: Control Cabinet Boiler

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

A

E

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 12

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 12

0-8100-100454-14-3

lables / Schilder 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

Starter box feed water pump A

A

AE1380.500

380 x 380 x 210 mm

Schaltschrankfarbe: Color of control cabinet: color : Munsel 7,5 BG 7/2

B

C

M/ M1

2

C

3

6 XC

XC

XD

XD

D

all lines without indication of cross section are

D

0

SAACKE SAACKE

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

B

E

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 20

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+BCCFWP2 sheet 20

0-8100-100454-14-3

front view / Frontansicht Starterbox FWP2 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

no.

name

0

device

function Alu label SAACKE

-

1 B

colour

-

2

H2

RD

lamp

feed water pump

failed

3

H1

GN

lamp

feed water pump

in operation

S1

-

switch

feed water pump

B

4 5

C

8 9 10

C

D

all lines without indication of cross section are

D

7

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

6

E

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 21

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 21

0-8100-100454-14-3

lables Starterbox FWP 2 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

Starter box feed water pump 2 A

A

AE1380.500

B

380 x 380 x 210 mm

C

D

all lines without indication of cross section are

D

380

C

B

210

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

380

E

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 22

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 22

0-8100-100454-14-3

front view / Frontansicht Starterbox FWP 2 5

=BCC

6

7

19 8

sh.

F

1

2

3

4

5

6

7

8

B

40

0

0

N C

100

200

R

R

R

280

D

all lines without indication of cross section are

D

40

H07Z-K 1,5mm²

C

60

B

60

A

protection note according to ISO 16016 consider!

A

E

E

scale : 1:10 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 23

replaced for

3

replaced by

4

0-8100-100454-14 /3-32 6

+CC sheet 23

0-8100-100454-14-3

bore holes / Bohrungen Feed water pump 2 5

=BCC

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

B

B

-Q1

-K2

-F1

-Q2 -K1

-XPE

-X1

C

D

all lines without indication of cross section are

D

-X0

C

-T1

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

334

E

E

scale : 1:5 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 24

replaced for

3

replaced by

4

0-8100-100454-14 /3-32 6

+CC sheet 24

0-8100-100454-14-3

mounting plate / Montageplatte FW pump 2 5

=BCC

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

Bohrung / Bore hole: XA

Bohrung / Bore hole: XB

Bohrung / Bore hole: XC

(M16 x 1,5)

(M20 x 1,5)

(M25 x 1,5)

Bohrung / Bore hole: XD

Bohrung / Bore hole: XE

(M32 x 1,5)

(M40 x 1,5)

protection note according to ISO 16016 consider!

40,3

32,3

25,5

Kabelverschraubungen /

Kabelverschraubungen /

Kabelverschraubungen /

Kabelverschraubungen /

high-strength cable gland

high-strength cable gland

high-strength cable gland

high-strength cable gland

51,20 40,50 32,50

C

27,30 22,70

SW 20

SW 36

SW 28

SW 24

SW 45

D

all lines without indication of cross section are

D

Kabelverschraubungen / high-strength cable gland

H07Z-K 1,5mm²

C

20,3

B 16,3

B

E

E

scale : 1:5 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 25

replaced for

3

replaced by

4

0-8100-100454-14 /3-32 6

+CC sheet 25

0-8100-100454-14-3

mounting plate / Montageplatte FW pump 2 5

=BCC

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

A

bore holes flansh plate

240 200 B

B

150

100

XB

XB

XC

C

D

all lines without indication of cross section are

D

XC

90

C

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

50

E

E

scale : 1:5 scale unit : mm

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 26

replaced for

3

replaced by

4

0-8100-100454-14 /3-32 6

+CC sheet 26

0-8100-100454-14-3

mounting plate / Montageplatte FW pump 2 5

=BCC

7

19 8

sh.

F

1

2

3

4

5

6

7

8

A

B

B

Schaltkastenrückseite mit Wandbefestigung

Wandbefestigungshalter

20

59 20

15

12

10,2

3

7

8,5

C

54

36

18

18

30

12

D

all lines without indication of cross section are

D

wall mounting bracket

D

C

control box back side with wall mountig bracket

H07Z-K 1,5mm²

protection note according to ISO 16016 consider!

A

E

E

F

F

0

as built

R. modification

1

date

2012-01-30

drawn

ROS

check

ROS

30.01.2012

ROS

date

name standard

Control Cabinet Boiler origin

2

layout diagram / Aufbauplan 27

replaced for

3

replaced by

4

0-8100-100454-14 /3-32

+CC sheet 27

0-8100-100454-14-3

wall mountig holders Starterbox FWP 2 5

=BCCz72

6

7

19 8

sh.

item list no.

1

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

260739

Filterlüfter

strainer fan

=BCC+CC_D-8M6 fan cabinet

RITTAL

=BCC/8.6 2

SK 3323.107

=BCC+CC_D-8M6

604351

Austrittsfilter

fan cabinet =BCC/8.6 3

SK 3322.207

=BCC+CC_D-90H1

613315

Meldeleuchte weiß

1. control voltage selected

CL-502W

=BCC+CC_D-90H2

613312

Meldeleuchte grün

fuel oil pump 1

CL-502G

=BCC+CC_D-90H3

613312

Meldeleuchte grün

fuel oil pump 2

CL-502G

=BCC+CC_D-90H4

613312

Meldeleuchte grün

feed water pump 1

protection note according to DIN 34 consider !

CL-502G

=BCC+CC_D-90H5

613312

Meldeleuchte grün

feed water pump 2

CL-502G

=BCC+CC_D-90H6

613312

Meldeleuchte grün

chemical dosing pump

CL-502G

=BCC+CC_D-90H7

613312

Meldeleuchte grün

MGO pump 1

CL-502G

=BCC+CC_D-90H8

613312

Meldeleuchte grün

MGO pump 2

CL-502G

=BCC+CC_D-92H2

613313

Meldeleuchte gelb

burner standby

CL-502Y

=BCC+CC_D-92H3

613312

Meldeleuchte grün

burner in operation

CL-502G

=BCC+CC_D-92H4

613312

Meldeleuchte grün

rotary cup

CL-502G

=BCC+CC_D-92H5

613312

Meldeleuchte grün

ignition oil pump

CL-502G

=BCC+CC_D-92H6

613312

Meldeleuchte grün

comb.air fan

CL-502G

=BCC+CC_D-92H7

613312

Meldeleuchte grün

preheater

CL-502G

=BCC+CC_D-92H8

613315

Meldeleuchte weiß

2. control voltage selected

CL-502W

=BCC+CC_D-92H9

613311

Meldeleuchte rot

alarm

CL-502R

=BCC+CC_D-1Q2

634179

Lasttrennschalter Frontmontage schwarz

main switch Hauptschalter

switch disconnector front mounting black

ABB

=BCC/1.2 20

lamp red

ABB

=BCC/92.7 19

lamp white

ABB

=BCC/92.6 18

lamp green

ABB

=BCC/92.6 17

lamp green

ABB

=BCC/92.5 16

lamp green

ABB

=BCC/92.4 15

lamp green

ABB

=BCC/92.4 14

lamp green

ABB

=BCC/92.3 13

lamp yellow

ABB

=BCC/92.2 12

lamp green

ABB

=BCC/90.6 11

lamp green

ABB

=BCC/90.6 10

lamp green

ABB

=BCC/90.5 9

lamp green

ABB

=BCC/90.5 8

lamp green

ABB

=BCC/90.4 7

lamp green

ABB

=BCC/90.3 6

lamp green

ABB

=BCC/90.3 5

lamp white

ABB

=BCC/90.2 4

discharge strainer

RITTAL

OT100ET3HS7ST4

=BCC+CC_D-1Q2

634180

Lasttrennschalter Frontmontage schwarz

main switch Hauptschalter

switch disconnector front mounting black

ABB

=BCC/1.2

OT100ET3HS7ST4

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 1

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 1 25

sh.

item list no.

21

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

634181

Lasttrennschalter Frontmontage schwarz

switch disconnector front mounting black

=BCC+CC_D-1Q2 main switch Hauptschalter

ABB

=BCC/1.2 22

OT100ET3HS7ST4

=BCC+CC_D-1Q5

634179

Lasttrennschalter Frontmontage schwarz

main switch Hauptschalter =BCC/1.5 23

OT100ET3HS7ST4

=BCC+CC_D-1Q5

634180

Lasttrennschalter Frontmontage schwarz

main switch Hauptschalter

OT100ET3HS7ST4

=BCC+CC_D-1Q5

634181

Lasttrennschalter Frontmontage schwarz

main switch Hauptschalter

OT100ET3HS7ST4

=BCC+CC_D-2P5

606022

Strommesser

combustion air fan

EQ 72s 20/5A

=BCC+CC_D-2P5

510651

Gummidichtung

combustion air fan

protection note according to DIN 34 consider !

72x72mm

=BCC+CC_D-9S1

614546

NOT-AUS-TASTER

boiler stop Kessel Stop

CE4T-10R-02

=BCC+CC_D-9S8

613304

DRUCKTASTER SCHWARZ

reset emergency stop Reset Not-Stop

CP1-10B-11

=BCC+CC_D-16S3

012095

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-16S3

012102

BETAETIGUNGSVORSATZ

mode Betriebsart

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-16S3

145542

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-16S4

012095

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-16S4

012102

BETAETIGUNGSVORSATZ

mode Betriebsart

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-16S4

145542

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-19S3

012095

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-19S3

012102

BETAETIGUNGSVORSATZ

mode Betriebsart

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-19S3

145542

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-19S4

012095

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-19S4

012102

BETAETIGUNGSVORSATZ

mode Betriebsart

CONTROL HEAD

TELEMECANIQUE

=BCC/19.5 40

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/19.5 39

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/19.3 38

CONTROL HEAD

TELEMECANIQUE

=BCC/19.3 37

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/19.3 36

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/16.4 35

CONTROL HEAD

TELEMECANIQUE

=BCC/16.4 34

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/16.4 33

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/16.3 32

CONTROL HEAD

TELEMECANIQUE

=BCC/16.3 31

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/16.3 30

PUSHBUTTON BLACK

ABB

=BCC/9.7 29

IP54

EMERGENCY-STOP

ABB

=BCC/9.2 28

grommet

CELSA

=BCC/2.5 27

AMMETER

Celsa

=BCC/2.5 26

switch disconnector front mounting black

ABB

=BCC/1.5 25

switch disconnector front mounting black

ABB

=BCC/1.5 24

switch disconnector front mounting black

ABB

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-19S4

145542

STEUERSCHALTER

mode Betriebsart

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/19.5

K1D 002U

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 2

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 2 25

sh.

item list no.

41

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

012095

STEUERSCHALTER

CHANGE-OVER SWITCH

=BCC+CC_D-23S3 mode Betriebsart

TELEMECANIQUE

=BCC/23.3 42

K1D 002U

=BCC+CC_D-23S3

012102

BETAETIGUNGSVORSATZ

mode Betriebsart =BCC/23.3 43

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-23S3

145542

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-23S4

012095

STEUERSCHALTER

mode Betriebsart

K1D 002U

=BCC+CC_D-23S4

012102

BETAETIGUNGSVORSATZ

mode Betriebsart

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-23S4

145542

STEUERSCHALTER

mode Betriebsart

protection note according to DIN 34 consider !

K1D 002U

=BCC+CC_D-27S2

012093

STEUERSCHALTER

chemical dosing pump Chemikaliendosierpumpe

K1A 001A

=BCC+CC_D-27S2

012102

BETAETIGUNGSVORSATZ

chemical dosing pump Chemikaliendosierpumpe

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-27S2

145541

STEUERSCHALTER

chemical dosing pump Chemikaliendosierpumpe

K1A 001A

=BCC+CC_D-30P5

011566

Betriebsstundenzähler

rotary cup atomizer Drehzerstäuber

631.2/879-220V/60Hz

=BCC+CC_D-30S2

012094

STEUERSCHALTER

combustion air fan

K1B 001U

=BCC+CC_D-30S2

012102

BETAETIGUNGSVORSATZ

combustion air fan

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-30S2

146120

STEUERSCHALTER

combustion air fan

K1B 001U

=BCC+CC_D-35S5

012094

STEUERSCHALTER

burner mode Brenner Betriebsart

K1B 001U

=BCC+CC_D-35S5

012102

BETAETIGUNGSVORSATZ

burner mode Brenner Betriebsart

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-35S5

145542

STEUERSCHALTER

burner mode Brenner Betriebsart

K1B 001U

=BCC+CC_D-36S5

613304

DRUCKTASTER SCHWARZ

reset burner

CP1-10B-11

=BCC+CC_D-39S2

012098

STEUERSCHALTER

selection flame scanner emergency operation

K1B 011U

=BCC+CC_D-39S2

012102

BETAETIGUNGSVORSATZ

selection flame scanner emergency operation

CONTROL HEAD

TELEMECANIQUE

=BCC/39.2 60

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/39.2 59

PUSHBUTTON BLACK

ABB

=BCC/36.6 58

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/35.4 57

CONTROL HEAD

TELEMECANIQUE

=BCC/35.4 56

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/35.4 55

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/30.2 54

CONTROL HEAD

TELEMECANIQUE

=BCC/30.2 53

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/30.2 52

operation recorder

Bauser

=BCC/30.5 51

START SWITCH

TELEMECANIQUE

=BCC/27.2 50

CONTROL HEAD

TELEMECANIQUE

=BCC/27.2 49

START SWITCH

TELEMECANIQUE

=BCC/27.2 48

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/23.4 47

CONTROL HEAD

TELEMECANIQUE

=BCC/23.4 46

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/23.4 45

CHANGE-OVER SWITCH

TELEMECANIQUE

=BCC/23.3 44

CONTROL HEAD

TELEMECANIQUE

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-39S2

145547

STEUERSCHALTER

selection flame scanner emergency operation

CHANGE OVER SWITCH

TELEMECANIQUE

=BCC/39.2

K1B 011U

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 3

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 3 25

sh.

item list no.

61

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

012093

STEUERSCHALTER

START SWITCH

=BCC+CC_D-42S6 release load control

TELEMECANIQUE

=BCC/42.6 62

K1A 001A

=BCC+CC_D-42S6

012102

BETAETIGUNGSVORSATZ

release load control =BCC/42.6 63

KBC 1B-MIT BEZEICHNU

=BCC+CC_D-42S6

145541

STEUERSCHALTER

release load control

START SWITCH

TELEMECANIQUE

=BCC/42.6 64

CONTROL HEAD

TELEMECANIQUE

K1A 001A

=BCC+CC_D-60N3

528974

REGLER, PRORAMMIERBAR

CONTROLLER, PROGRAMABLE

SAACKE =BCC/60.3 65

RSE-P II ENGLISCH

=BCC+CC_D-60N3

RSEP01

Programm Lastregelung w=8bar

PROGRAM LOAD CONTROL SP=8BAR

Saacke =BCC/60.3 66

RSE-PII

=BCC+CC_D-92S7

613304

DRUCKTASTER SCHWARZ

lamp test Lampenprüfung

protection note according to DIN 34 consider !

=BCC/92.8 67

PUSHBUTTON BLACK

ABB CP1-10B-11

=BCC+CC_M-1F3

610118

Sicherungsautomat

automatic circuit breaker

ABB =BCC/1.3 68

S 202-C 1

=BCC+CC_M-1F6

610118

Sicherungsautomat

automatic circuit breaker

ABB =BCC/1.6 69

S 202-C 1

=BCC+CC_M-1K3

635662

LEISTUNGSSCHUETZ

power supply 1 =BCC/1.3 70

1 SBL 371 001 R 86

=BCC+CC_M-1K3

635663

Löschglied

power supply 1

SBN 0500 10R 1003

=BCC+CC_M-1K6

635662

LEISTUNGSSCHUETZ

power supply 2

1 SBL 371 001 R 86 2

=BCC+CC_M-1K6

635663

Löschglied

power supply 2

SBN 0500 10R 1003

=BCC+CC_M-2Q2

529941

Motorschutzschalter

rotary cup atomizer

MS 325-4

=BCC+CC_M-2Q2

622058

Hilfsschalter

rotary cup atomizer

HKF-20

=BCC+CC_M-2Q2

603281

Hilfsschalter

rotary cup atomizer

HK-11

=BCC+CC_M-2Q3

529940

Motorschutzschalter

ignition oil pump

MS 325-1

=BCC+CC_M-2Q3

622058

Hilfsschalter

ignition oil pump

HKF-20

=BCC+CC_M-2Q3

603281

Hilfsschalter

ignition oil pump

HK-11

=BCC+CC_M-2Q5

531353

Motorschutzschalter

combustion air fan

motor protection switch

ABB

=BCC/2.6 80

auxiliary contact

ABB

=BCC/2.4 79

MOTOR PROTECTION SWITCH

ABB

=BCC/2.4 78

motor protection switch

ABB

=BCC/2.4 77

auxiliary contact

ABB

=BCC/2.2 76

MOTOR PROTECTION SWITCH

ABB

=BCC/2.2 75

motor protection switch

ABB

=BCC/2.2 74

RV5 / 440

ABB

=BCC/1.6 73

ABB

ABB

=BCC/1.6 72

RV5 / 440

ABB

=BCC/1.3 71

A-63-30-22

ABB

MS 325-20

=BCC+CC_M-2Q5

622058

Hilfsschalter

combustion air fan

MOTOR PROTECTION SWITCH

ABB

=BCC/2.6

HKF-20

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 4

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 4 25

sh.

item list no.

81

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

603281

Hilfsschalter

auxiliary contact

=BCC+CC_M-2Q5 combustion air fan

ABB

=BCC/2.6 82

HK-11

=BCC+CC_M-2T5

613399

Stromwandler Kl. 1

combustion air fan =BCC/2.6 83

WST40 (20/5A)

=BCC+CC_M-3Q2

529940

Motorschutzschalter

fuel oil pump 1

MS 325-1

=BCC+CC_M-3Q2

622058

Hilfsschalter

fuel oil pump 1

HKF-20

=BCC+CC_M-3Q2

603281

Hilfsschalter

fuel oil pump 1

HK-11

=BCC+CC_M-3Q3

529940

Motorschutzschalter

fuel oil pump 2

protection note according to DIN 34 consider !

MS 325-1

=BCC+CC_M-3Q3

622058

Hilfsschalter

fuel oil pump 2

HKF-20

=BCC+CC_M-3Q3

603281

Hilfsschalter

fuel oil pump 2

HK-11

=BCC+CC_M-3Q5

529940

Motorschutzschalter

MGO pump 1

MS 325-1

=BCC+CC_M-3Q5

622058

Hilfsschalter

MGO pump 1

HKF-20

=BCC+CC_M-3Q5

603281

Hilfsschalter

MGO pump 1

HK-11

=BCC+CC_M-3Q7

529940

Motorschutzschalter

MGOpump 2

MS 325-1

=BCC+CC_M-3Q7

622058

Hilfsschalter

MGOpump 2

HKF-20

=BCC+CC_M-3Q7

603281

Hilfsschalter

MGOpump 2

HK-11

=BCC+CC_M-4Q2 feed water

603279

Motorschutzschalter

pump 1

MS 325-6,3

=BCC+CC_M-4Q2 feed water

622058

Hilfsschalter

pump 1

HKF-20

=BCC+CC_M-4Q2 feed water

603281

Hilfsschalter

pump 1

HK-11

=BCC+CC_M-5F2

610107

Sicherungsautomat

chemical dosing pump

S 201-C 1

=BCC+CC_M-5F2

610117

Hilfsschalter (1 W)

chemical dosing pump

auxiliary switch (1 CO)

ABB

=BCC/5.2 100

automatic circuit breaker

ABB

=BCC/5.2 99

auxiliary contact

ABB

=BCC/4.2 98

MOTOR PROTECTION SWITCH

ABB

=BCC/4.2 97

motor protection switch

ABB

=BCC/4.2 96

auxiliary contact

ABB

=BCC/3.7 95

MOTOR PROTECTION SWITCH

ABB

=BCC/3.7 94

motor protection switch

ABB

=BCC/3.7 93

auxiliary contact

ABB

=BCC/3.5 92

MOTOR PROTECTION SWITCH

ABB

=BCC/3.5 91

motor protection switch

ABB

=BCC/3.5 90

auxiliary contact

ABB

=BCC/3.4 89

MOTOR PROTECTION SWITCH

ABB

=BCC/3.4 88

motor protection switch

ABB

=BCC/3.4 87

auxiliary contact

ABB

=BCC/3.2 86

MOTOR PROTECTION SWITCH

ABB

=BCC/3.2 85

motor protection switch

ABB

=BCC/3.2 84

CURRENT TRANSFORMER CL. 1

Celsa

S2C-H6R

=BCC+CC_M-5Q4

603728

Motorschutzschalter

electrical preheater

motor protection switch

ABB

=BCC/5.4

MS325-16

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 5

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 5 25

sh.

item list no.

101

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

622058

Hilfsschalter

MOTOR PROTECTION SWITCH

=BCC+CC_M-5Q4 electrical preheater

ABB

=BCC/5.4 102

HKF-20

=BCC+CC_M-5Q4

603281

Hilfsschalter

electrical preheater =BCC/5.4 103

HK-11

=BCC+CC_M-7F3

610113

Sicherungsautomat

24V AC supply

S 201-C 4

=BCC+CC_M-7F4

610113

Sicherungsautomat

230V AC supply

S 201-C 4

=BCC+CC_M-7K5

515358

RELAIS

power fault

40.52.8.230

=BCC+CC_M-7K5

629903

RELAIS

power fault

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-7K5

515355

SCHRAUBFASSUNG BLAU

power fault

95.95.1

=BCC+CC_M-7K5

515356

Haltebügel blau

power fault

095.91

=BCC+CC_M-7Q2

603279

Motorschutzschalter

control voltage

MS 325-6,3

=BCC+CC_M-7T2

511024

TRANSFORMATOR

440V/230V 1600VA control transformer

TRANSFORMER

BLOCK

=BCC/7.2 111

motor protection switch

ABB

=BCC/7.2 110

hold-down clip blue

FINDER

=BCC/7.5 109

SOCKET BLUE

FINDER

=BCC/7.5 108

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/7.5 107

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/7.5 106

automatic circuit breaker

ABB

=BCC/7.4 105

automatic circuit breaker

ABB

=BCC/7.3 104

auxiliary contact

ABB

STU 1600/2x115

=BCC+CC_M-8B6 Thermostat =BCC/8.6

112

SK 3110000

=BCC+CC_M-8B6

250222

TEMPERATUR-REGLER

Thermostat =BCC/8.6 113

SK 3110000

=BCC+CC_M-8F2

610112

Sicherungsautomat

power supply burner equipment

S 201-C 2

=BCC+CC_M-8F3

610114

Sicherungsautomat

power supply heating tracer

S 201-C 6

=BCC+CC_M-8F4

610114

Sicherungsautomat

power supply boiler equipment

S 201-C 6

=BCC+CC_M-8F5

610112

Sicherungsautomat

power supply MGO pumps

S 201-C 2

=BCC+CC_M-8F6

610112

Sicherungsautomat

fan socket 230V

automatic circuit breaker

ABB

=BCC/8.6 118

automatic circuit breaker

ABB

=BCC/8.5 117

automatic circuit breaker

ABB

=BCC/8.4 116

automatic circuit breaker

ABB

=BCC/8.3 115

automatic circuit breaker

ABB

=BCC/8.2 114

TEMPERATURE CONTROLLER

RITTAL

S 201-C 2

=BCC+CC_M-8X8

524473

STECKDOSE FUER SCHALTSCHRANKEINBAU

PLUG FOR PANEL MOUNTING

HAGER =BCC/8.8 119

SN016

=BCC+CC_M-8X8

1

STECKDOSE FUER SCHALTSCHRANKEINBAU

PLUG FOR PANEL MOUNTING

HAGER =BCC/8.8 120

SN016

=BCC+CC_M-9K5

634413

Sicherheits-Schaltgerät

emergency stop

safety device

H.Zander GmbH & Co.K

=BCC/9.4

SR3C AC230V

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 6

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 6 25

sh.

item list no.

121

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

510035

Hilfsschütz

auxiliary contactor

=BCC+CC_M-9K6 emergency stop

ABB

=BCC/9.6 122

N 40 E

=BCC+CC_M-9K6

526164

Löschglied

emergency stop

suppressor

ABB

=BCC/9.6 123

RC 5-1/250

=BCC+CC_M-9K6

603271

Hilfskontakt

emergency stop

auxiliary contact

ABB

=BCC/9.6 124

CA 5-10

=BCC+CC_M-9K6

603272

Hilfskontakt

emergency stop

auxiliary contact

ABB

=BCC/9.6 125

CA 5-01

=BCC+CC_M-9K7

510035

Hilfsschütz

emergency stop

auxiliary contactor

ABB

=BCC/9.6 126

N 40 E

=BCC+CC_M-9K7

526164

Löschglied

emergency stop

suppressor

ABB

protection note according to DIN 34 consider !

=BCC/9.6 127

RC 5-1/250

=BCC+CC_M-9K7

603271

Hilfskontakt

emergency stop

auxiliary contact

ABB

=BCC/9.6 128

CA 5-10

=BCC+CC_M-9K7

603272

Hilfskontakt

emergency stop

auxiliary contact

ABB

=BCC/9.6 129

CA 5-01

=BCC+CC_M-9K8

515358

RELAIS

reset emergency stop

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/9.7 130

40.52.8.230

=BCC+CC_M-9K8

629903

RELAIS

reset emergency stop

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/9.7 131

40.52.8.230

=BCC+CC_M-9K8

515355

SCHRAUBFASSUNG BLAU

reset emergency stop

SOCKET BLUE

FINDER

=BCC/9.7 132

95.95.1

=BCC+CC_M-9K8

515356

Haltebügel blau

reset emergency stop

hold-down clip blue

FINDER

=BCC/9.7 133

095.91

=BCC+CC_M-10A2

601264

PROGRAMMIERBARE STEUERUNG

PROGRAMMABLE CONTROL

SAACKE =BCC/10.2 134

LOGO 230 RCO

=BCC+CC_M-10A2

LOGO39

PROGRAMMIERBARE STEUERUNG

PROGRAMMABLE CONTROL

SAACKE =BCC/10.2 135

LOGO 230 RCO

=BCC+CC_M-10A3

601265

PROGRAMMIERBARE STEUERUNG ERWEITERUNG

PROGRAMMABLE CONTROL ADDITIONAL MODULE

SAACKE =BCC/10.3 136

LOGO DM 8 230R

=BCC+CC_M-10R2

627467

Metalloxid-Varistor S10K275

metal oxide varistor S10K275

Schuricht =BCC/10.2 137

B722110S271K101

=BCC+CC_M-10R3

627467

Metalloxid-Varistor S10K275

metal oxide varistor S10K275

Schuricht =BCC/10.3 138

B722110S271K101

=BCC+CC_M-11F4

610107

Sicherungsautomat

safety devices =BCC/11.4 139

S 201-C 1

=BCC+CC_M-11F5

610113

Sicherungsautomat

24V DC supply

automatic circuit breaker

ABB

=BCC/11.5 140

automatic circuit breaker

ABB

S 201-C 4

=BCC+CC_M-11G2

629443

GLEICHSTROMVERSORGUNG

power supply 230VAC/24VDC 5A

DIRECT CURRENT SUPPLY

Weidmüller

=BCC/11.2

STN 120 W 5A

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 7

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 7 25

sh.

item list no.

141

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

143200

FEUERUNGSAUTOMAT OEL

FIRING SEQUENCE CONTROL SYSTEM

=BCC+CC_M-12A3

SAACKE =BCC/12.3 142

F-OSA

=BCC+CC_M-12K2

515358

RELAIS

fault F-OSA

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/12.2 143

40.52.8.230

=BCC+CC_M-12K2

629903

RELAIS

fault F-OSA

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/12.2 144

40.52.8.230

=BCC+CC_M-12K2

515355

SCHRAUBFASSUNG BLAU

fault F-OSA =BCC/12.2 145

95.95.1

=BCC+CC_M-12K2

515356

Haltebügel blau

fault F-OSA

hold-down clip blue

FINDER

=BCC/12.2 146

SOCKET BLUE

FINDER

095.91

=BCC+CC_M-13A1

633897

CPU224XP

14DE, 10DA

CPU224XP

14DI, 10DO

SIEMENS

protection note according to DIN 34 consider !

=BCC/13.2 147

6ES7 214-2BD23-0XB0

=BCC+CC_M-13A1.1

632133

Digital Input 16 x 24VDC

Digital Input 16 x 24VDC

SIEMENS =BCC/13.4 148

6ES7- 221-1BH22-0XA0

=BCC+CC_M-13A5

632135

Operator Panel TP177micro

Blue Mode-LC-Display

SIEMENS =BCC/13.5 149

6AV6640-0CA11-0AX1

=BCC+CC_M-13A5

632136

Operator Panel TP177micro

Blue Mode-LC-Display

SIEMENS =BCC/13.5 150

6AV6640-0CA11-0AX1

=BCC+CC_M-14A1

632133

Digital Input 16 x 24VDC

Digital Input 16 x 24VDC

SIEMENS =BCC/14.1 151

6ES7 221-1BH22-0XA0

=BCC+CC_M-14A1.1

632133

Digital Input 16 x 24VDC

Digital Input 16 x 24VDC

SIEMENS =BCC/14.4 152

6ES7 221-1BH22-0XA0

=BCC+CC_M-15A1

632137

Digital Outut 8x Relay

Digital Outut 8x Relay

SIEMENS =BCC/15.1 153

6ES7 222-1HF22-0XA0

=BCC+CC_M-15A1.1

632137

Digital Outut 8x Relay

Digital Outut 8x Relay

SIEMENS =BCC/15.3 154

6ES7 222-1HF22-0XA0

=BCC+CC_M-16K7

515358

RELAIS

press. switch FOP =BCC/16.7 155

40.52.8.230

=BCC+CC_M-16K7

629903

RELAIS

press. switch FOP

40.52.8.230

=BCC+CC_M-16K7

515355

SCHRAUBFASSUNG BLAU

press. switch FOP

95.95.1

=BCC+CC_M-16K7

515356

Haltebügel blau

press. switch FOP

095.91

=BCC+CC_M-17K2

527018

Leistungsschütz

oil pump 1

A9-30-10

=BCC+CC_M-17K2

526164

Löschglied

oil pump 1

suppressor

ABB

=BCC/17.2 160

power contactor

ABB

=BCC/17.2 159

hold-down clip blue

FINDER

=BCC/16.7 158

SOCKET BLUE

FINDER

=BCC/16.7 157

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/16.7 156

PRINT RELAY,2-CHANGER,230 VAC

FINDER

RC 5-1/250

=BCC+CC_M-17K2

603271

Hilfskontakt

oil pump 1

auxiliary contact

ABB

=BCC/17.2

CA 5-10

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 8

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 8 25

sh.

item list no.

161

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

603282

Adapter

adapter

=BCC+CC_M-17K2 oil pump 1

ABB

=BCC/17.2 162

BEA 16/325

=BCC+CC_M-17K7

515358

RELAIS

local / remote =BCC/17.7 163

40.52.8.230

=BCC+CC_M-17K7

629903

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-17K7

515355

SCHRAUBFASSUNG BLAU

local / remote

95.95.1

=BCC+CC_M-17K7

515356

Haltebügel blau

local / remote

095.91

=BCC+CC_M-17K8

515358

RELAIS

FOP1 Standby fault

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-17K8

629903

RELAIS

FOP1 Standby fault

40.52.8.230

=BCC+CC_M-17K8

515355

SCHRAUBFASSUNG BLAU

FOP1 Standby fault

95.95.1

=BCC+CC_M-17K8

515356

Haltebügel blau

FOP1 Standby fault

095.91

=BCC+CC_M-18K2

527018

Leistungsschütz

oil pump 2

A9-30-10

=BCC+CC_M-18K2

526164

Löschglied

oil pump 2

RC 5-1/250

=BCC+CC_M-18K2

603271

Hilfskontakt

oil pump 2

CA 5-10

=BCC+CC_M-18K2

603282

Adapter

oil pump 2

BEA 16/325

=BCC+CC_M-18K7

515358

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-18K7

629903

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-18K7

515355

SCHRAUBFASSUNG BLAU

local / remote

95.95.1

=BCC+CC_M-18K7

515356

Haltebügel blau

local / remote

095.91

=BCC+CC_M-18K8

515358

RELAIS

FOP1 Standby fault

40.52.8.230

=BCC+CC_M-18K8

629903

RELAIS

FOP1 Standby fault

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/18.8 180

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/18.8 179

hold-down clip blue

FINDER

=BCC/18.7 178

SOCKET BLUE

FINDER

=BCC/18.7 177

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/18.7 176

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/18.7 175

adapter

ABB

=BCC/18.2 174

auxiliary contact

ABB

=BCC/18.2 173

suppressor

ABB

=BCC/18.2 172

power contactor

ABB

=BCC/18.2 171

hold-down clip blue

FINDER

=BCC/17.8 170

SOCKET BLUE

FINDER

=BCC/17.8 169

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/17.8 168

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/17.8 167

hold-down clip blue

FINDER

=BCC/17.7 166

SOCKET BLUE

FINDER

=BCC/17.7 165

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/17.7 164

PRINT RELAY,2-CHANGER,230 VAC

FINDER

40.52.8.230

=BCC+CC_M-18K8

515355

SCHRAUBFASSUNG BLAU

FOP1 Standby fault

SOCKET BLUE

FINDER

=BCC/18.8

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 9

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 9 25

sh.

item list no.

181

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-18K8 FOP1 Standby fault

FINDER

=BCC/18.8 182

095.91

=BCC+CC_M-19K7

515358

RELAIS

press.switch FWP =BCC/19.7 183

40.52.8.230

=BCC+CC_M-19K7

629903

RELAIS

press.switch FWP

40.52.8.230

=BCC+CC_M-19K7

515355

SCHRAUBFASSUNG BLAU

press.switch FWP

95.95.1

=BCC+CC_M-19K7

515356

Haltebügel blau

press.switch FWP

095.91

=BCC+CC_M-20K2

527018

Leistungsschütz

feed water pump 1

protection note according to DIN 34 consider !

A9-30-10

=BCC+CC_M-20K2

526164

Löschglied

feed water pump 1

RC 5-1/250

=BCC+CC_M-20K2

603271

Hilfskontakt

feed water pump 1

CA 5-10

=BCC+CC_M-20K2

603282

Adapter

feed water pump 1

BEA 16/325

=BCC+CC_M-20K3

515358

RELAIS

FWP1 Standby fault

40.52.8.230

=BCC+CC_M-20K3

629903

RELAIS

FWP1 Standby fault

40.52.8.230

=BCC+CC_M-20K3

515355

SCHRAUBFASSUNG BLAU

FWP1 Standby fault

95.95.1

=BCC+CC_M-20K3

515356

Haltebügel blau

FWP1 Standby fault

095.91

=BCC+CC_M-20K7

515358

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-20K7

629903

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-20K7

515355

SCHRAUBFASSUNG BLAU

local / remote

95.95.1

=BCC+CC_M-20K7

515356

Haltebügel blau

local / remote

095.91

=BCC+CC_M-22K2

515358

RELAIS

feed water pump 2 on

40.52.8.230

=BCC+CC_M-22K2

629903

RELAIS

feed water pump 2 on

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.2 200

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.2 199

hold-down clip blue

FINDER

=BCC/20.7 198

SOCKET BLUE

FINDER

=BCC/20.7 197

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/20.7 196

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/20.7 195

hold-down clip blue

FINDER

=BCC/20.3 194

SOCKET BLUE

FINDER

=BCC/20.3 193

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/20.3 192

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/20.3 191

adapter

ABB

=BCC/20.2 190

auxiliary contact

ABB

=BCC/20.2 189

suppressor

ABB

=BCC/20.2 188

power contactor

ABB

=BCC/20.2 187

hold-down clip blue

FINDER

=BCC/19.7 186

SOCKET BLUE

FINDER

=BCC/19.7 185

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/19.7 184

PRINT RELAY,2-CHANGER,230 VAC

FINDER

40.52.8.230

=BCC+CC_M-22K2

515355

SCHRAUBFASSUNG BLAU

feed water pump 2 on

SOCKET BLUE

FINDER

=BCC/22.2

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 10

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 10 25

sh.

item list no.

201

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-22K2 feed water pump 2 on

FINDER

=BCC/22.2 202

095.91

=BCC+CC_M-22K3

515358

RELAIS

FWP2 Standbyfault =BCC/22.2 203

40.52.8.230

=BCC+CC_M-22K3

629903

RELAIS

FWP2 Standbyfault

40.52.8.230

=BCC+CC_M-22K3

515355

SCHRAUBFASSUNG BLAU

FWP2 Standbyfault

95.95.1

=BCC+CC_M-22K3

515356

Haltebügel blau

FWP2 Standbyfault

095.91

=BCC+CC_M-22K6

515358

RELAIS

local stop

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-22K6

629903

RELAIS

local stop

40.52.8.230

=BCC+CC_M-22K6

515355

SCHRAUBFASSUNG BLAU

local stop

95.95.1

=BCC+CC_M-22K6

515356

Haltebügel blau

local stop

095.91

=BCC+CC_M-22K7

526294

RELAIS

feed water pump 2 in operation

55.34.8.230.00.40

=BCC+CC_M-22K7

629903

RELAIS

feed water pump 2 in operation

40.52.8.230

=BCC+CC_M-22K7

526291

SCHRAUBFASSUNG BLAU

feed water pump 2 in operation

94.84.03

=BCC+CC_M-22K7

526292

Haltebügel blau

feed water pump 2 in operation

094.91

=BCC+CC_M-22K8

515358

RELAIS

feed water pump 2 overload

40.52.8.230

=BCC+CC_M-22K8

629903

RELAIS

feed water pump 2 overload

40.52.8.230

=BCC+CC_M-22K8

515355

SCHRAUBFASSUNG BLAU

feed water pump 2 overload

95.95.1

=BCC+CC_M-22K8

515356

Haltebügel blau

feed water pump 2 overload

095.91

=BCC+CC_M-23K7

515358

RELAIS

press. switch MGO

40.52.8.230

=BCC+CC_M-23K7

629903

RELAIS

press. switch MGO

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/23.7 220

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/23.7 219

hold-down clip blue

FINDER

=BCC/22.8 218

SOCKET BLUE

FINDER

=BCC/22.8 217

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.8 216

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.8 215

hold-down clip blue

FINDER

=BCC/22.7 214

SOCKET BLUE

FINDER

=BCC/22.7 213

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.7 212

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/22.7 211

hold-down clip blue

FINDER

=BCC/22.6 210

SOCKET BLUE

FINDER

=BCC/22.6 209

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.6 208

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.6 207

hold-down clip blue

FINDER

=BCC/22.2 206

SOCKET BLUE

FINDER

=BCC/22.2 205

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/22.2 204

PRINT RELAY,2-CHANGER,230 VAC

FINDER

40.52.8.230

=BCC+CC_M-23K7

515355

SCHRAUBFASSUNG BLAU

press. switch MGO

SOCKET BLUE

FINDER

=BCC/23.7

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 11

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 11 25

sh.

item list no.

221

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-23K7 press. switch MGO

FINDER

=BCC/23.7 222

095.91

=BCC+CC_M-24K2

527018

Leistungsschütz

MGO pump 1 =BCC/24.2 223

A9-30-10

=BCC+CC_M-24K2

526164

Löschglied

MGO pump 1

RC 5-1/250

=BCC+CC_M-24K2

603271

Hilfskontakt

MGO pump 1

CA 5-10

=BCC+CC_M-24K2

603282

Adapter

MGO pump 1

BEA 16/325

=BCC+CC_M-24K7

515358

RELAIS

local / remote

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-24K7

629903

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-24K7

515355

SCHRAUBFASSUNG BLAU

local / remote

95.95.1

=BCC+CC_M-24K7

515356

Haltebügel blau

local / remote

095.91

=BCC+CC_M-24K8

515358

RELAIS

FOP1 Standby fault

40.52.8.230

=BCC+CC_M-24K8

629903

RELAIS

FOP1 Standby fault

40.52.8.230

=BCC+CC_M-24K8

515355

SCHRAUBFASSUNG BLAU

FOP1 Standby fault

95.95.1

=BCC+CC_M-24K8

515356

Haltebügel blau

FOP1 Standby fault

095.91

=BCC+CC_M-25K2

527018

Leistungsschütz

MGO pump 2

A9-30-10

=BCC+CC_M-25K2

526164

Löschglied

MGO pump 2

RC 5-1/250

=BCC+CC_M-25K2

603271

Hilfskontakt

MGO pump 2

CA 5-10

=BCC+CC_M-25K2

603282

Adapter

MGO pump 2

BEA 16/325

=BCC+CC_M-25K7

515358

RELAIS

local / remote

40.52.8.230

=BCC+CC_M-25K7

629903

RELAIS

local / remote

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/25.7 240

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/25.7 239

adapter

ABB

=BCC/25.2 238

auxiliary contact

ABB

=BCC/25.2 237

suppressor

ABB

=BCC/25.2 236

power contactor

ABB

=BCC/25.2 235

hold-down clip blue

FINDER

=BCC/24.8 234

SOCKET BLUE

FINDER

=BCC/24.8 233

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/24.8 232

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/24.8 231

hold-down clip blue

FINDER

=BCC/24.7 230

SOCKET BLUE

FINDER

=BCC/24.7 229

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/24.7 228

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/24.7 227

adapter

ABB

=BCC/24.2 226

auxiliary contact

ABB

=BCC/24.2 225

suppressor

ABB

=BCC/24.2 224

power contactor

ABB

40.52.8.230

=BCC+CC_M-25K7

515355

SCHRAUBFASSUNG BLAU

local / remote

SOCKET BLUE

FINDER

=BCC/25.7

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 12

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 12 25

sh.

item list no.

241

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-25K7 local / remote

FINDER

=BCC/25.7 242

095.91

=BCC+CC_M-25K8

515358

RELAIS

FOP2 Standby fault =BCC/25.8 243

40.52.8.230

=BCC+CC_M-25K8

629903

RELAIS

FOP2 Standby fault

40.52.8.230

=BCC+CC_M-25K8

515355

SCHRAUBFASSUNG BLAU

FOP2 Standby fault

95.95.1

=BCC+CC_M-25K8

515356

Haltebügel blau

FOP2 Standby fault

095.91

=BCC+CC_M-27K2

526294

RELAIS

chemical dosing pump in operation

protection note according to DIN 34 consider !

55.34.8.230.00.40

=BCC+CC_M-27K2

629903

RELAIS

chemical dosing pump in operation

40.52.8.230

=BCC+CC_M-27K2

526291

SCHRAUBFASSUNG BLAU

chemical dosing pump in operation

94.84.03

=BCC+CC_M-27K2

526292

Haltebügel blau

chemical dosing pump in operation

094.91

=BCC+CC_M-27K3

515358

RELAIS

accoustic com alarm

40.52.8.230

=BCC+CC_M-27K3

629903

RELAIS

accoustic com alarm

40.52.8.230

=BCC+CC_M-27K3

515355

SCHRAUBFASSUNG BLAU

accoustic com alarm

95.95.1

=BCC+CC_M-27K3

515356

Haltebügel blau

accoustic com alarm

095.91

=BCC+CC_M-27K4

515358

RELAIS

flame failure (ECR)

40.52.8.230

=BCC+CC_M-27K4

629903

RELAIS

flame failure (ECR)

40.52.8.230

=BCC+CC_M-27K4

515355

SCHRAUBFASSUNG BLAU

flame failure (ECR)

95.95.1

=BCC+CC_M-27K4

515356

Haltebügel blau

flame failure (ECR)

095.91

=BCC+CC_M-27K5

515358

RELAIS

alarm comb.air low ( ECR)

40.52.8.230

=BCC+CC_M-27K5

629903

RELAIS

alarm comb.air low ( ECR)

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.5 260

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.5 259

hold-down clip blue

FINDER

=BCC/27.4 258

SOCKET BLUE

FINDER

=BCC/27.4 257

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.4 256

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.4 255

hold-down clip blue

FINDER

=BCC/27.3 254

SOCKET BLUE

FINDER

=BCC/27.3 253

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.3 252

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.3 251

hold-down clip blue

FINDER

=BCC/27.2 250

SOCKET BLUE

FINDER

=BCC/27.2 249

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.2 248

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/27.2 247

hold-down clip blue

FINDER

=BCC/25.8 246

SOCKET BLUE

FINDER

=BCC/25.8 245

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/25.8 244

PRINT RELAY,2-CHANGER,230 VAC

FINDER

40.52.8.230

=BCC+CC_M-27K5

515355

SCHRAUBFASSUNG BLAU

alarm comb.air low ( ECR)

SOCKET BLUE

FINDER

=BCC/27.5

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 13

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 13 25

sh.

item list no.

261

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-27K5 alarm comb.air low ( ECR)

FINDER

=BCC/27.5 262

095.91

=BCC+CC_M-27K6

515358

RELAIS

alarm ( cabinet) =BCC/27.6 263

40.52.8.230

=BCC+CC_M-27K6

629903

RELAIS

alarm ( cabinet)

40.52.8.230

=BCC+CC_M-27K6

515355

SCHRAUBFASSUNG BLAU

alarm ( cabinet)

95.95.1

=BCC+CC_M-27K6

515356

Haltebügel blau

alarm ( cabinet)

095.91

=BCC+CC_M-27K7

515358

RELAIS

common alarm ( ECR )

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-27K7

629903

RELAIS

common alarm ( ECR )

40.52.8.230

=BCC+CC_M-27K7

515355

SCHRAUBFASSUNG BLAU

common alarm ( ECR )

95.95.1

=BCC+CC_M-27K7

515356

Haltebügel blau

common alarm ( ECR )

095.91

=BCC+CC_M-27K8

515358

RELAIS

common shut down alarm ( cabinet)

40.52.8.230

=BCC+CC_M-27K8

629903

RELAIS

common shut down alarm ( cabinet)

40.52.8.230

=BCC+CC_M-27K8

515355

SCHRAUBFASSUNG BLAU

common shut down alarm ( cabinet)

95.95.1

=BCC+CC_M-27K8

515356

Haltebügel blau

common shut down alarm ( cabinet)

095.91

=BCC+CC_M-28K4

534245

Leistungsschütz

electrical preheater

A16-30-10

=BCC+CC_M-28K4

526164

Löschglied

electrical preheater

RC 5-1/250

=BCC+CC_M-28K4

603282

Adapter

electrical preheater

BEA 16/325

=BCC+CC_M-30K2

603730

Leistungsschütz

combustion air fan

A26-30-10

=BCC+CC_M-30K2

526164

Löschglied

combustion air fan

RC 5-1/250

=BCC+CC_M-30K2

603271

Hilfskontakt

combustion air fan

auxiliary contact

ABB

=BCC/30.2 280

suppressor

ABB

=BCC/30.2 279

power contactor

ABB

=BCC/30.2 278

adapter

ABB

=BCC/28.4 277

suppressor

ABB

=BCC/28.4 276

power contactor

ABB

=BCC/28.4 275

hold-down clip blue

FINDER

=BCC/27.8 274

SOCKET BLUE

FINDER

=BCC/27.8 273

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.8 272

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.8 271

hold-down clip blue

FINDER

=BCC/27.7 270

SOCKET BLUE

FINDER

=BCC/27.7 269

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.7 268

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.7 267

hold-down clip blue

FINDER

=BCC/27.6 266

SOCKET BLUE

FINDER

=BCC/27.6 265

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/27.6 264

PRINT RELAY,2-CHANGER,230 VAC

FINDER

CA 5-10

=BCC+CC_M-30K2

603272

Hilfskontakt

combustion air fan

auxiliary contact

ABB

=BCC/30.2

CA 5-01

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 14

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 14 25

sh.

item list no.

281

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

603640

Adapter

adapter

=BCC+CC_M-30K2 combustion air fan

ABB

=BCC/30.2 282

BEA 26/325

=BCC+CC_M-30K4

527018

Leistungsschütz

rotary cup atomizer =BCC/30.4 283

A9-30-10

=BCC+CC_M-30K4

526164

Löschglied

rotary cup atomizer

RC 5-1/250

=BCC+CC_M-30K4

603271

Hilfskontakt

rotary cup atomizer

CA 5-10

=BCC+CC_M-30K4

603272

Hilfskontakt

rotary cup atomizer

CA 5-01

=BCC+CC_M-30K4

603282

Adapter

rotary cup atomizer

protection note according to DIN 34 consider !

BEA 16/325

=BCC+CC_M-30K6

527018

Leistungsschütz

ignition oil pump

A9-30-10

=BCC+CC_M-30K6

526164

Löschglied

ignition oil pump

RC 5-1/250

=BCC+CC_M-30K6

603271

Hilfskontakt

ignition oil pump

CA 5-10

=BCC+CC_M-30K6

603272

Hilfskontakt

ignition oil pump

CA 5-01

=BCC+CC_M-30K6

603282

Adapter

ignition oil pump

BEA 16/325

=BCC+CC_M-32K2

515358

RELAIS

combustion air fan

40.52.8.230

=BCC+CC_M-32K2

629903

RELAIS

combustion air fan

40.52.8.230

=BCC+CC_M-32K2

515355

SCHRAUBFASSUNG BLAU

combustion air fan

95.95.1

=BCC+CC_M-32K2

515356

Haltebügel blau

combustion air fan

095.91

=BCC+CC_M-32K6

515358

RELAIS

rotary cup atomizer

40.52.8.230

=BCC+CC_M-32K6

629903

RELAIS

rotary cup atomizer

40.52.8.230

=BCC+CC_M-32K6

515355

SCHRAUBFASSUNG BLAU

rotary cup atomizer

95.95.1

=BCC+CC_M-32K6

515356

Haltebügel blau

rotary cup atomizer

hold-down clip blue

FINDER

=BCC/32.6 300

SOCKET BLUE

FINDER

=BCC/32.6 299

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/32.6 298

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/32.6 297

hold-down clip blue

FINDER

=BCC/32.2 296

SOCKET BLUE

FINDER

=BCC/32.2 295

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/32.2 294

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/32.2 293

adapter

ABB

=BCC/30.6 292

auxiliary contact

ABB

=BCC/30.6 291

auxiliary contact

ABB

=BCC/30.6 290

suppressor

ABB

=BCC/30.6 289

power contactor

ABB

=BCC/30.6 288

adapter

ABB

=BCC/30.4 287

auxiliary contact

ABB

=BCC/30.4 286

auxiliary contact

ABB

=BCC/30.4 285

suppressor

ABB

=BCC/30.4 284

power contactor

ABB

095.91

=BCC+CC_M-33K4

634413

Sicherheits-Schaltgerät

safety interlock circuit

safety device

H.Zander GmbH & Co.K

=BCC/33.4

SR3C AC230V

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 15

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 15 25

sh.

item list no.

301

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

510035

Hilfsschütz

auxiliary contactor

=BCC+CC_M-34K6 emergency operation

ABB

=BCC/34.6 302

N 40 E

=BCC+CC_M-34K6

526164

Löschglied

emergency operation =BCC/34.6 303

RC 5-1/250

=BCC+CC_M-34K6

603271

Hilfskontakt

emergency operation

CA 5-10

=BCC+CC_M-34K6

603272

Hilfskontakt

emergency operation

CA 5-01

=BCC+CC_M-34K6

603272

Hilfskontakt

emergency operation

CA 5-01

=BCC+CC_M-34K7

510036

HILFSSCHUETZ

emergency operation

protection note according to DIN 34 consider !

N 44E

=BCC+CC_M-34K7

526164

Löschglied

emergency operation

RC 5-1/250

=BCC+CC_M-35K2

526294

RELAIS

burner start

55.34.8.230.00.40

=BCC+CC_M-35K2

629903

RELAIS

burner start

40.52.8.230

=BCC+CC_M-35K2

526291

SCHRAUBFASSUNG BLAU

burner start

94.84.03

=BCC+CC_M-35K2

526292

Haltebügel blau

burner start

094.91

=BCC+CC_M-35K6

515358

RELAIS

burner stand by

40.52.8.230

=BCC+CC_M-35K6

629903

RELAIS

burner stand by

40.52.8.230

=BCC+CC_M-35K6

515355

SCHRAUBFASSUNG BLAU

burner stand by

95.95.1

=BCC+CC_M-35K6

515356

Haltebügel blau

burner stand by

095.91

=BCC+CC_M-36K3

515358

RELAIS

purge position

40.52.8.230

=BCC+CC_M-36K3

629903

RELAIS

purge position

40.52.8.230

=BCC+CC_M-36K3

515355

SCHRAUBFASSUNG BLAU

purge position

95.95.1

=BCC+CC_M-36K3

515356

Haltebügel blau

purge position

hold-down clip blue

FINDER

=BCC/36.2 320

SOCKET BLUE

FINDER

=BCC/36.2 319

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/36.2 318

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/36.2 317

hold-down clip blue

FINDER

=BCC/35.5 316

SOCKET BLUE

FINDER

=BCC/35.5 315

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/35.5 314

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/35.5 313

hold-down clip blue

FINDER

=BCC/35.2 312

SOCKET BLUE

FINDER

=BCC/35.2 311

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/35.2 310

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/35.2 309

suppressor

ABB

=BCC/34.7 308

AUXILIARY CONTACTOR

ABB

=BCC/34.7 307

auxiliary contact

ABB

=BCC/34.6 306

auxiliary contact

ABB

=BCC/34.6 305

auxiliary contact

ABB

=BCC/34.6 304

suppressor

ABB

095.91

=BCC+CC_M-36K7

515358

RELAIS

reset

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/36.6

40.52.8.230

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 16

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 16 25

sh.

item list no.

321

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

629903

RELAIS

PRINT RELAY,2-CHANGER,230 VAC

=BCC+CC_M-36K7 reset

FINDER

=BCC/36.6 322

40.52.8.230

=BCC+CC_M-36K7

515355

SCHRAUBFASSUNG BLAU

reset =BCC/36.6 323

95.95.1

=BCC+CC_M-36K7

515356

Haltebügel blau

reset

095.91

=BCC+CC_M-37K7

515358

RELAIS

ignition

40.52.8.230

=BCC+CC_M-37K7

629903

RELAIS

ignition

40.52.8.230

=BCC+CC_M-37K7

515355

SCHRAUBFASSUNG BLAU

ignition

protection note according to DIN 34 consider !

95.95.1

=BCC+CC_M-37K7

515356

Haltebügel blau

ignition

095.91

=BCC+CC_M-38K2

515358

RELAIS

oil valves

40.52.8.230

=BCC+CC_M-38K2

629903

RELAIS

oil valves

40.52.8.230

=BCC+CC_M-38K2

515355

SCHRAUBFASSUNG BLAU

oil valves

95.95.1

=BCC+CC_M-38K2

515356

Haltebügel blau

oil valves

095.91

=BCC+CC_M-39A3

602164

FLAMMENWAECHTER

flame detector 1 Flammenwächter 1

FLUS 06 UV

=BCC+CC_M-39K3

510037

HILFSSCHUETZ

flame signal 1

N 62E

=BCC+CC_M-39K3

526164

Löschglied

flame signal 1

RC 5-1/250

=BCC+CC_M-40A3

602164

FLAMMENWAECHTER

flame detector 2 Flammenwächter 2

FLUS 06 UV

=BCC+CC_M-40K3

510037

HILFSSCHUETZ

flame signal 2

N 62E

=BCC+CC_M-40K3

526164

Löschglied

flame signal 2

RC 5-1/250

=BCC+CC_M-41K5

515358

RELAIS

ignition

40.52.8.230

=BCC+CC_M-41K5

629903

RELAIS

ignition

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/41.5 340

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/41.5 339

suppressor

ABB

=BCC/40.3 338

AUXILIARY CONTACTOR

ABB

=BCC/40.3 337

FLAME DETECTOR

SAACKE

=BCC/40.3 336

suppressor

ABB

=BCC/39.3 335

AUXILIARY CONTACTOR

ABB

=BCC/39.3 334

FLAME DETECTOR

SAACKE

=BCC/39.3 333

hold-down clip blue

FINDER

=BCC/38.2 332

SOCKET BLUE

FINDER

=BCC/38.2 331

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/38.2 330

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/38.2 329

hold-down clip blue

FINDER

=BCC/37.7 328

SOCKET BLUE

FINDER

=BCC/37.7 327

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/37.7 326

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/37.7 325

hold-down clip blue

FINDER

=BCC/36.6 324

SOCKET BLUE

FINDER

40.52.8.230

=BCC+CC_M-41K5

515355

SCHRAUBFASSUNG BLAU

ignition

SOCKET BLUE

FINDER

=BCC/41.5

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 17

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 17 25

sh.

item list no.

341

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-41K5 ignition

FINDER

=BCC/41.5 342

095.91

=BCC+CC_M-42K2

526294

RELAIS

purge =BCC/42.2 343

55.34.8.230.00.40

=BCC+CC_M-42K2

629903

RELAIS

purge

40.52.8.230

=BCC+CC_M-42K2

526291

SCHRAUBFASSUNG BLAU

purge

94.84.03

=BCC+CC_M-42K2

526292

Haltebügel blau

purge

094.91

=BCC+CC_M-42K3

515358

RELAIS

end of purge

protection note according to DIN 34 consider !

40.52.8.230

=BCC+CC_M-42K3

629903

RELAIS

end of purge

40.52.8.230

=BCC+CC_M-42K3

515355

SCHRAUBFASSUNG BLAU

end of purge

95.95.1

=BCC+CC_M-42K3

515356

Haltebügel blau

end of purge

095.91

=BCC+CC_M-42K4

515358

RELAIS

release flame scanner

40.52.8.230

=BCC+CC_M-42K4

629903

RELAIS

release flame scanner

40.52.8.230

=BCC+CC_M-42K4

515355

SCHRAUBFASSUNG BLAU

release flame scanner

95.95.1

=BCC+CC_M-42K4

515356

Haltebügel blau

release flame scanner

095.91

=BCC+CC_M-42K5

526294

RELAIS

burner fires

55.34.8.230.00.40

=BCC+CC_M-42K5

629903

RELAIS

burner fires

40.52.8.230

=BCC+CC_M-42K5

526291

SCHRAUBFASSUNG BLAU

burner fires

94.84.03

=BCC+CC_M-42K5

526292

Haltebügel blau

burner fires

094.91

=BCC+CC_M-42K6

526294

RELAIS

control

55.34.8.230.00.40

=BCC+CC_M-42K6

629903

RELAIS

control

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.6 360

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/42.6 359

hold-down clip blue

FINDER

=BCC/42.5 358

SOCKET BLUE

FINDER

=BCC/42.5 357

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.5 356

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/42.5 355

hold-down clip blue

FINDER

=BCC/42.4 354

SOCKET BLUE

FINDER

=BCC/42.4 353

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.4 352

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.4 351

hold-down clip blue

FINDER

=BCC/42.3 350

SOCKET BLUE

FINDER

=BCC/42.3 349

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.3 348

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.3 347

hold-down clip blue

FINDER

=BCC/42.2 346

SOCKET BLUE

FINDER

=BCC/42.2 345

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/42.2 344

MINIATURE-RELAY 4CHANGE-OVER

FINDER

40.52.8.230

=BCC+CC_M-42K6

526291

SCHRAUBFASSUNG BLAU

control

SOCKET BLUE

FINDER

=BCC/42.6

94.84.03

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 18

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 18 25

sh.

item list no.

361

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

526292

Haltebügel blau

hold-down clip blue

=BCC+CC_M-42K6 control

FINDER

=BCC/42.6 362

094.91

=BCC+CC_M-43K2

515358

RELAIS

fault =BCC/43.2 363

40.52.8.230

=BCC+CC_M-43K2

629903

RELAIS

fault

40.52.8.230

=BCC+CC_M-43K2

515355

SCHRAUBFASSUNG BLAU

fault

95.95.1

=BCC+CC_M-43K2

515356

Haltebügel blau

fault

095.91

=BCC+CC_M-44K4

634414

Sicherheits-Schaltgerät

primary air failure

protection note according to DIN 34 consider !

SR3C AC/DC24V

=BCC+CC_M-45K4

634414

Sicherheits-Schaltgerät

combustion air failure

SR3C AC/DC24V

=BCC+CC_M-46K6

634414

Sicherheits-Schaltgerät

burner swung out

SR3C AC/DC24V

=BCC+CC_M-46K8

515357

RELAIS

burner swung out

40.52.9.024

=BCC+CC_M-46K8

515359

LED-Anzeige rot

burner swung out

LED-ANZEIGE

=BCC+CC_M-46K8

515355

SCHRAUBFASSUNG BLAU

burner swung out

95.95.1

=BCC+CC_M-46K8

515356

Haltebügel blau

burner swung out

095.91

=BCC+CC_M-47K5

622489

HILFSSCHUETZ

purge position

NL 40E

=BCC+CC_M-47K5

615592

Löschglied

purge position

RT 5/32

=BCC+CC_M-47K5

603271

Hilfskontakt

purge position

CA 5-10

=BCC+CC_M-47K5

603272

Hilfskontakt

purge position

CA 5-01

=BCC+CC_M-47K6

526293

RELAIS

ignition position

55.34.9.024.00.40

=BCC+CC_M-47K6

515359

LED-Anzeige rot

ignition position

LED-ANZEIGE

=BCC+CC_M-47K6

526291

SCHRAUBFASSUNG BLAU

ignition position

SOCKET BLUE

FINDER

=BCC/47.6 380

LED indication red

FINDER

=BCC/47.6 379

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/47.6 378

auxiliary contact

ABB

=BCC/47.5 377

auxiliary contact

ABB

=BCC/47.5 376

suppressor

ABB

=BCC/47.5 375

AUXILIARY CONTACTOR

ABB

=BCC/47.5 374

hold-down clip blue

FINDER

=BCC/46.7 373

SOCKET BLUE

FINDER

=BCC/46.7 372

LED indication red

FINDER

=BCC/46.7 371

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/46.7 370

safety device

H.Zander GmbH & Co.K

=BCC/46.6 369

safety device

H.Zander GmbH & Co.K

=BCC/45.4 368

safety device

H.Zander GmbH & Co.K

=BCC/44.4 367

hold-down clip blue

FINDER

=BCC/43.2 366

SOCKET BLUE

FINDER

=BCC/43.2 365

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/43.2 364

PRINT RELAY,2-CHANGER,230 VAC

FINDER

94.84.03

=BCC+CC_M-47K6

526292

Haltebügel blau

ignition position

hold-down clip blue

FINDER

=BCC/47.6

094.91

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 19

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 19 25

sh.

item list no.

381

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

634414

Sicherheits-Schaltgerät

safety device

=BCC+CC_M-48K6 fire in the windbox

H.Zander GmbH & Co.K

=BCC/48.6 382

SR3C AC/DC24V

=BCC+CC_M-49K6

634414

Sicherheits-Schaltgerät

oil pressure too high =BCC/49.6 383

SR3C AC/DC24V

=BCC+CC_M-50K6

634414

Sicherheits-Schaltgerät

HFO temperature too low

SR3C AC/DC24V

=BCC+CC_M-51K6

526293

RELAIS

HFO temperature high

55.34.9.024.00.40

=BCC+CC_M-51K6

515359

LED-Anzeige rot

HFO temperature high

LED-ANZEIGE

=BCC+CC_M-51K6

526291

SCHRAUBFASSUNG BLAU

HFO temperature high

protection note according to DIN 34 consider !

94.84.03

=BCC+CC_M-51K6

526292

Haltebügel blau

HFO temperature high

094.91

=BCC+CC_M-52K6

634414

Sicherheits-Schaltgerät

steam pressure too high

SR3C AC/DC24V

=BCC+CC_M-53K6

634414

Sicherheits-Schaltgerät

flue gas temperature too high

SR3C AC/DC24V

=BCC+CC_M-55K5

515357

RELAIS

fuel oil circulating to pump

40.52.9.024

=BCC+CC_M-55K5

515359

LED-Anzeige rot

fuel oil circulating to pump

LED-ANZEIGE

=BCC+CC_M-55K5

515355

SCHRAUBFASSUNG BLAU

fuel oil circulating to pump

95.95.1

=BCC+CC_M-55K5

515356

Haltebügel blau

fuel oil circulating to pump

095.91

=BCC+CC_M-55K6

515357

RELAIS

fuel oil circulating to tank

40.52.9.024

=BCC+CC_M-55K6

515359

LED-Anzeige rot

fuel oil circulating to tank

LED-ANZEIGE

=BCC+CC_M-55K6

515355

SCHRAUBFASSUNG BLAU

fuel oil circulating to tank

95.95.1

=BCC+CC_M-55K6

515356

Haltebügel blau

fuel oil circulating to tank

095.91

=BCC+CC_M-56K6

622489

HILFSSCHUETZ

HFO operation selected

NL 40E

=BCC+CC_M-56K6

615592

Löschglied

HFO operation selected

suppressor

ABB

=BCC/56.6 400

AUXILIARY CONTACTOR

ABB

=BCC/56.6 399

hold-down clip blue

FINDER

=BCC/55.6 398

SOCKET BLUE

FINDER

=BCC/55.6 397

LED indication red

FINDER

=BCC/55.6 396

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/55.6 395

hold-down clip blue

FINDER

=BCC/55.5 394

SOCKET BLUE

FINDER

=BCC/55.5 393

LED indication red

FINDER

=BCC/55.5 392

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/55.5 391

safety device

H.Zander GmbH & Co.K

=BCC/53.6 390

safety device

H.Zander GmbH & Co.K

=BCC/52.6 389

hold-down clip blue

FINDER

=BCC/51.6 388

SOCKET BLUE

FINDER

=BCC/51.6 387

LED indication red

FINDER

=BCC/51.6 386

MINIATURE-RELAY 4CHANGE-OVER

FINDER

=BCC/51.6 385

safety device

H.Zander GmbH & Co.K

=BCC/50.6 384

safety device

H.Zander GmbH & Co.K

RT 5/32

=BCC+CC_M-56K6

603271

Hilfskontakt

HFO operation selected

auxiliary contact

ABB

=BCC/56.6

CA 5-10

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 20

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 20 25

sh.

item list no.

401

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

603272

Hilfskontakt

auxiliary contact

=BCC+CC_M-56K6 HFO operation selected

ABB

=BCC/56.6 402

CA 5-01

=BCC+CC_M-57K6

622489

HILFSSCHUETZ

MDO selected =BCC/57.6 403

NL 40E

=BCC+CC_M-57K6

615592

Löschglied

MDO selected

RT 5/32

=BCC+CC_M-57K6

603271

Hilfskontakt

MDO selected

CA 5-10

=BCC+CC_M-57K6

603272

Hilfskontakt

MDO selected

CA 5-01

=BCC+CC_M-59K4

515357

RELAIS

selection HFO / MDO

protection note according to DIN 34 consider !

40.52.9.024

=BCC+CC_M-59K4

515359

LED-Anzeige rot

selection HFO / MDO

LED-ANZEIGE

=BCC+CC_M-59K4

515355

SCHRAUBFASSUNG BLAU

selection HFO / MDO

95.95.1

=BCC+CC_M-59K4

515356

Haltebügel blau

selection HFO / MDO

095.91

=BCC+CC_M-59K7

622489

HILFSSCHUETZ

MGO operation

NL 40E

=BCC+CC_M-59K7

615592

Löschglied

MGO operation

RT 5/32

=BCC+CC_M-59K7

603271

Hilfskontakt

MGO operation

CA 5-10

=BCC+CC_M-59K7

603272

Hilfskontakt

MGO operation

CA 5-01

=BCC+CC_M-61K2

515357

RELAIS

boiler purge

40.52.9.024

=BCC+CC_M-61K2

515359

LED-Anzeige rot

boiler purge

LED-ANZEIGE

=BCC+CC_M-61K2

515355

SCHRAUBFASSUNG BLAU

boiler purge

95.95.1

=BCC+CC_M-61K2

515356

Haltebügel blau

boiler purge

095.91

=BCC+CC_M-61K3

515357

RELAIS

increase burner load

40.52.9.024

=BCC+CC_M-61K3

515359

LED-Anzeige rot

increase burner load

LED indication red

FINDER

=BCC/61.3 420

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/61.3 419

hold-down clip blue

FINDER

=BCC/61.3 418

SOCKET BLUE

FINDER

=BCC/61.3 417

LED indication red

FINDER

=BCC/61.3 416

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/61.3 415

auxiliary contact

ABB

=BCC/59.7 414

auxiliary contact

ABB

=BCC/59.7 413

suppressor

ABB

=BCC/59.7 412

AUXILIARY CONTACTOR

ABB

=BCC/59.7 411

hold-down clip blue

FINDER

=BCC/59.4 410

SOCKET BLUE

FINDER

=BCC/59.4 409

LED indication red

FINDER

=BCC/59.4 408

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/59.4 407

auxiliary contact

ABB

=BCC/57.6 406

auxiliary contact

ABB

=BCC/57.6 405

suppressor

ABB

=BCC/57.6 404

AUXILIARY CONTACTOR

ABB

LED-ANZEIGE

=BCC+CC_M-61K3

515355

SCHRAUBFASSUNG BLAU

increase burner load

SOCKET BLUE

FINDER

=BCC/61.3

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 21

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 21 25

sh.

item list no.

421

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-61K3 increase burner load

FINDER

=BCC/61.3 422

095.91

=BCC+CC_M-61K4

515357

RELAIS

decrease burner load =BCC/61.4 423

40.52.9.024

=BCC+CC_M-61K4

515359

LED-Anzeige rot

decrease burner load

LED-ANZEIGE

=BCC+CC_M-61K4

515355

SCHRAUBFASSUNG BLAU

decrease burner load

95.95.1

=BCC+CC_M-61K4

515356

Haltebügel blau

decrease burner load

095.91

=BCC+CC_M-63K3

515357

RELAIS

controlled shut-down

protection note according to DIN 34 consider !

40.52.9.024

=BCC+CC_M-63K3

515359

LED-Anzeige rot

controlled shut-down

LED-ANZEIGE

=BCC+CC_M-63K3

515355

SCHRAUBFASSUNG BLAU

controlled shut-down

95.95.1

=BCC+CC_M-63K3

515356

Haltebügel blau

controlled shut-down

095.91

=BCC+CC_M-63K4

515357

RELAIS

steam pressure low/high

40.52.9.024

=BCC+CC_M-63K4

515359

LED-Anzeige rot

steam pressure low/high

LED-ANZEIGE

=BCC+CC_M-63K4

515355

SCHRAUBFASSUNG BLAU

steam pressure low/high

95.95.1

=BCC+CC_M-63K4

515356

Haltebügel blau

steam pressure low/high

095.91

=BCC+CC_M-63K5

515357

RELAIS

steam pressure high

40.52.9.024

=BCC+CC_M-63K5

515359

LED-Anzeige rot

steam pressure high

LED-ANZEIGE

=BCC+CC_M-63K5

515355

SCHRAUBFASSUNG BLAU

steam pressure high

95.95.1

=BCC+CC_M-63K5

515356

Haltebügel blau

steam pressure high

095.91

=BCC+CC_M-63K6

515357

RELAIS

steam pressure low

40.52.9.024

=BCC+CC_M-63K6

515359

LED-Anzeige rot

steam pressure low

LED indication red

FINDER

=BCC/63.6 440

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/63.6 439

hold-down clip blue

FINDER

=BCC/63.5 438

SOCKET BLUE

FINDER

=BCC/63.5 437

LED indication red

FINDER

=BCC/63.5 436

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/63.5 435

hold-down clip blue

FINDER

=BCC/63.4 434

SOCKET BLUE

FINDER

=BCC/63.4 433

LED indication red

FINDER

=BCC/63.4 432

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/63.4 431

hold-down clip blue

FINDER

=BCC/63.3 430

SOCKET BLUE

FINDER

=BCC/63.3 429

LED indication red

FINDER

=BCC/63.3 428

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

=BCC/63.3 427

hold-down clip blue

FINDER

=BCC/61.4 426

SOCKET BLUE

FINDER

=BCC/61.4 425

LED indication red

FINDER

=BCC/61.4 424

PRINT RELAY, 2-CHANGER, 24VDC

FINDER

LED-ANZEIGE

=BCC+CC_M-63K6

515355

SCHRAUBFASSUNG BLAU

steam pressure low

SOCKET BLUE

FINDER

=BCC/63.6

95.95.1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 22

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 22 25

sh.

item list no.

441

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515356

Haltebügel blau

hold-down clip blue

=BCC+CC_M-63K6 steam pressure low

FINDER

=BCC/63.6 442

095.91

=BCC+CC_M-69A2

635419

GRENZWERTSCHALTER, NIVEAU

level limit switch Niveauschalter =BCC/69.2 443

NRS 1-50s , 15sek.Tr

=BCC+CC_M-69K5

634413

Sicherheits-Schaltgerät

boiler water level 1 too low

safety device

H.Zander GmbH & Co.K

=BCC/69.5 444

limit switch, level

GESTRA

SR3C AC230V

=BCC+CC_M-70A2

629178 PR electronics

=BCC/70.2 445

PReasy 4116

=BCC+CC_M-70A2

629183 PR electronics

=BCC/70.2 446

PReasy 4116

=BCC+CC_M-70K5

526293

RELAIS

boiler water level 2 too low

protection note according to DIN 34 consider !

=BCC/70.4 447

55.34.9.024.00.40

=BCC+CC_M-70K5

515359

LED-Anzeige rot

boiler water level 2 too low

LED-ANZEIGE

=BCC+CC_M-70K5

526291

SCHRAUBFASSUNG BLAU

boiler water level 2 too low

94.84.03

=BCC+CC_M-70K5

526292

Haltebügel blau

boiler water level 2 too low

hold-down clip blue

FINDER

=BCC/70.4 450

SOCKET BLUE

FINDER

=BCC/70.4 449

LED indication red

FINDER

=BCC/70.4 448

MINIATURE-RELAY 4CHANGE-OVER

FINDER

094.91

=BCC+CC_M-73A2

629178 PR electronics

=BCC/73.2 451

PReasy 4116

=BCC+CC_M-73A2

629183 PR electronics

=BCC/73.2 452

PReasy 4116

=BCC+CC_M-74K6

515358

RELAIS

low water alarm =BCC/74.7 453

40.52.8.230

=BCC+CC_M-74K6

629903

RELAIS

low water alarm

40.52.8.230

=BCC+CC_M-74K6

515355

SCHRAUBFASSUNG BLAU

low water alarm

95.95.1

=BCC+CC_M-74K6

515356

Haltebügel blau

low water alarm

095.91

=BCC+CC_M-74K7

515358

RELAIS

high water alarm

40.52.8.230

=BCC+CC_M-74K7

629903

RELAIS

high water alarm

40.52.8.230

=BCC+CC_M-74K7

515355

SCHRAUBFASSUNG BLAU

high water alarm

95.95.1

=BCC+CC_M-74K7

515356

Haltebügel blau

high water alarm

hold-down clip blue

FINDER

=BCC/74.7 460

SOCKET BLUE

FINDER

=BCC/74.7 459

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/74.7 458

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/74.7 457

hold-down clip blue

FINDER

=BCC/74.7 456

SOCKET BLUE

FINDER

=BCC/74.7 455

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/74.7 454

PRINT RELAY,2-CHANGER,230 VAC

FINDER

095.91

=BCC+CC_M-76K5

515358

RELAIS

conductivity high

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/76.5

40.52.8.230

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 23

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 23 25

sh.

item list no.

461

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515360

R/C-KOMBINATION

RC_MODULE

=BCC+CC_M-76K5 conductivity high

FINDER

=BCC/76.5 462

99.80.0230.09

=BCC+CC_M-76K5

515355

SCHRAUBFASSUNG BLAU

conductivity high =BCC/76.5 463

95.95.1

=BCC+CC_M-76K5

515356

Haltebügel blau

conductivity high

095.91

=BCC+CC_M-77K4

515358

RELAIS

oil turbidity

40.52.8.230

=BCC+CC_M-77K4

515360

R/C-KOMBINATION

oil turbidity

99.80.0230.09

=BCC+CC_M-77K4

515355

SCHRAUBFASSUNG BLAU

oil turbidity

protection note according to DIN 34 consider !

SOCKET BLUE

FINDER

=BCC/77.4 467

RC_MODULE

FINDER

=BCC/77.4 466

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/77.4 465

hold-down clip blue

FINDER

=BCC/76.5 464

SOCKET BLUE

FINDER

95.95.1

=BCC+CC_M-77K4

515356

Haltebügel blau

oil turbidity

hold-down clip blue

FINDER

=BCC/77.4

095.91

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 24

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 24 25

sh.

item list no.

481

item Betriebsmittel

part number

identifier 1 + 2

comment

additional info 1

producer

kind

presentation

additional info 2

odering number

type

515360

R/C-KOMBINATION

RC_MODULE

=BCC+CC_M-76K5 conductivity high

FINDER

=BCC/76.5 482

99.80.0230.09

=BCC+CC_M-76K5

515355

SCHRAUBFASSUNG BLAU

conductivity high =BCC/76.5 483

95.95.1

=BCC+CC_M-76K5

515356

Haltebügel blau

conductivity high

095.91

=BCC+CC_M-77K4

515358

RELAIS

oil turbidity

40.52.8.230

=BCC+CC_M-77K4

515360

R/C-KOMBINATION

oil turbidity

99.80.0230.09

=BCC+CC_M-77K4

515355

SCHRAUBFASSUNG BLAU

oil turbidity

protection note according to DIN 34 consider !

SOCKET BLUE

FINDER

=BCC/77.4 487

RC_MODULE

FINDER

=BCC/77.4 486

PRINT RELAY,2-CHANGER,230 VAC

FINDER

=BCC/77.4 485

hold-down clip blue

FINDER

=BCC/76.5 484

SOCKET BLUE

FINDER

95.95.1

=BCC+CC_M-77K4

515356

Haltebügel blau

oil turbidity

hold-down clip blue

FINDER

=BCC/77.4

095.91

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

item list / Geräte-Stückliste 25

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32

= +

0-8100-100454-14-3

sheet 25 25

sh.

cable list no.

1

item

number of wire

cablerun

kind of cable

comment

wires width

destination 1

identifier 1

reserve wires

cable type

cable length

destination 2

identifier 2

free wires

25

=BCC+CC_M-X0

Marine- cable

1.00

=BCC+MSB1-X

-BCC_1000

4

M4G25 2

-BCC_1001

3

-BCC_1002

4

-BCC_1003

5

-BCC_1004

-BCC_1005

protection note according to ISO 16016 consider!

-BCC_1006

-BCC_1007

-BCC_1008

10

-BCC_1009

-BCC_1010

-BCC_1011

-BCC_1012

-BCC_2005

15

-BCC_2006

-BCC_2008

-BCC_2009

-BCC_2020

-BCC_2022

20

4

2,5

=BCC+CC_M-X0

1.00

=BCC+BW-X8

Marine- cable

-BCC_2120

4

1,5

=BCC+CC_M-X0

1.00

=BCC+F-2M3

Marine- cable

0 0 4

2,5

=BCC+CC_M-X0

1.00

=BCC+FWP1-4M2

Marine- cable

0 0 4

2,5

=BCC+CC_M-X0

1.00

=BCC+FWP2-4M3

Marine- cable

0 0 4

1,5

=BCC+CC_M-X0

1.00

=BCC+MGOP1-3M5

Marine- cable

0 0 4

1,5

=BCC+CC_M-X0

1.00

=BCC+MGOP2-3M7

Marine- cable

0 0 4

1,5

=BCC+CC_M-X0

1.00

=BCC+FOP1-3M2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X0

1.00

=BCC+FOP2-3M3

Marine- cable

0 0 4

4

=BCC+CC_M-X0

1.00

=BCC+BN-X

Marine- cable

0 0 16

1,5

=BCC+CC_M-X1

1.00

=BCC+BW-X1.1

Marine- cable

0 0 3

1,5

=BCC+CC_M-X1

1.00

=BCC+BO-68B2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X1

1.00

=BCC+F-77A2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X1

1.00

=BCC+F-76A3

Marine- cable

0 0 3

1,5

=BCC+CC_M-X0

1.00

=BCC+FW-5M2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X1

1.00

=BCC+BN-X

Marine- cable

0 0

7

M7G1,5

0 0

4

M4G1,5

0 0

3

M3G1,5 19

=BCC+BN-2M5

4

M4G1,5 18

1.00

Marine- cable

4

M4G1,5 17

=BCC+CC_M-X0

3

M3G1,5 16

4

4

16

M16G1,5

0 0

4

M4G4 14

=BCC+FWP2-X0

4

M4G1,5 13

1.00

Marine- cable

4

M4G1,5 12

=BCC+FWP2+MSB2-X

4

M4G1,5 11

4

4

4

M4G1,5

0 0

4

M4G2,5 9

=BCC+MSB2-X

4

M4G2,5 8

1.00

Marine- cable

4

M4G1,5 7

=BCC+CC_M-X0

4

M4G2,5 6

4

35

4

M4G4

0 0

4

M4G4

proved wires

4

4

M4G35

laying system

6

1,5

=BCC+CC_M-X20

1.00

=BCC+FOP1-S3

Marine- cable

0 1

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

cable list / Kabelliste 1

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32 0-8100-100454-14-3

sheet 1 3

sh.

cable list no.

21

item

number of wire

cablerun

kind of cable

comment

wires width

destination 1

identifier 1

reserve wires

cable type

cable length

destination 2

identifier 2

free wires

1,5

=BCC+CC_M-X21

Marine- cable

1.00

=BCC+FOP2-S3

-BCC_2121

7

M7G1,5 22

-BCC_2122

23

-BCC_2123

24

-BCC_2220

25

-BCC_2221

-BCC_2222

protection note according to ISO 16016 consider!

-BCC_3001

-BCC_3002

-BCC_3005

30

-BCC_3006

-BCC_3007

-BCC_3008

-BCC_3010

-BCC_3012

35

-BCC_3014

-BCC_3016

-BCC_3018

-BCC_3020

-BCC_3021

40

6

1,5

=BCC+BCCFWP2-X1

1.00

=BCC+FWP2-S1

Marine- cable

-BCC_4000

7

1,5

=BCC+CC_M-X31

1.00

=BCC+BCCFWP2-X1

Marine- cable

0 0 2

1,5

=BCC.+CC-X2

1.00

=BCC.+F-9S2

Marine- cable

0 0 2

1,5

=BCC.+CC-X2

1.00

=BCC.+F-9S3

Marine- cable

0 0 10

1,5

=BCC+CC_M-X2

1.00

=BCC+BW-X2.1

Marine- cable

0 2 2

1,5

=BCC+CC_M-X2

1.00

=BCC+BO-52F2

Marine- cable

0 0 2

1,5

=BCC+CC_M-X2

1.00

=BCC+BO-53F2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X2

1.00

=BCC+F-55S2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X2

1.00

=BCC+F-56S2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X2

1.00

=BCC+F-56S3

Marine- cable

0 0 2

1,5

=BCC+CC_M-X1

1.00

=BCC+F-16F7

Marine- cable

0 0 2

1,5

=BCC+CC_M-X1

1.00

=BCC+FW-19F7-19F1

Marine- cable

0 0 2

1,5

=BCC+CC_M-X1

1.00

=BCC+GO 006-23F7

Marine- cable

0 0 4

1,5

=BCC+CC_M-X2

1.00

=BCC+F-59S2

Marine- cable

0 0 4

1,5

=BCC+CC_M-X2

1.00

=BCC+F-59S3

Marine- cable

0 0

3

M2x0,75SH

0 1

4

M4x1,5

0 1

4

M4x1,5 39

=BCC+FWP1-S3

2

M2X1,5 38

1.00

Marine- cable

2

M2X1,5 37

=BCC+CC_M-X30

2

M2X1,5 36

6

1,5

4

M4x1,5

0 1

4

M4x1,5 34

=BCC+MGOP2-S3

4

M4x1,5 33

1.00

Marine- cable

2

M2X1,5 32

=BCC+CC_M-X41

2

M2X1,5 31

6

1,5

12

M12x1,5

0 1

2

M2X1,5 29

=BCC+MGOP1-S3

2

M2X1,5 28

1.00

Marine- cable

7

M7G1,5 27

=BCC+CC_M-X40

7

M7G1,5 26

6

1,5

7

M7G1,5

0 1

7

M7G1,5

proved wires

6

7

M7G1,5

laying system

3

0,75

=BCC+CC_M-X3

1.00

=BCC+BO-64B2

Marine- cable screened

0 0

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

cable list / Kabelliste 2

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32 0-8100-100454-14-3

sheet 2 3

sh.

cable list no.

41

item

number of wire

cablerun

kind of cable

comment

wires width

destination 1

identifier 1

reserve wires

cable type

cable length

destination 2

identifier 2

free wires

0,75

=BCC+CC_M-X3

Marine- cable screened

1.00

=BCC+BW-X3.1

-BCC_4001

6

M5x0,75SH 42

-BCC_4002

43

-BCC_4003

44

-BCC_4005

45

-BCC_4011

-BCC_4099

protection note according to ISO 16016 consider!

-BCC_6001

-BCC_6010

-BCC_6011

50

-BCC_6012

-BCC_6013

1.00

-SH

Marine- cable screened

-BCC_6014

3

0,75

=BCC+CC_M-X3

1.00

=BCC+BO-68B2

Marine- cable screened

0 0 4

0,75

=BCC+CC_M-X3

1.00

=BCC+BW-X3.3

Marine- cable screened

0 0 4

0,75

=BCC+F-76A3

1.00

=BCC+F-86B3

Marine- cable screened

0 1 4

0,75

=BCC+CC_M-X6

1.00

=ECR+.-X

Marine- cable screened

0 2 24

1,5

=BCC+CC_M-X4

1.00

=BCC+ECR-X

Marine- cable

0 0 24

1,5

=BCC+CC_M-X4

1.00

=BCC+ECR-X

Marine- cable

0 0 18

1,5

=BCC+CC_M-X4

1.00

=BCC+ECR-X

Marine- cable

0 0 18

1,5

=BCC+CC_M-X4

1.00

=BCC+ECR-X

Marine- cable

0 0

18

M18x1,5

0 0

18

M18x1,5 52

=BCC+CC_M-X3

18

M18x1,5 51

5

0,75

24

M24x1,5

0 0

24

M24x1,5 49

=BCC+BW-X3.2

6

M5x0,75SH 48

1.00

Marine- cable screened

5

M4x0,75SH 47

=BCC+CC_M-X3

4

M3x0,75SH 46

6

0,75

3

M2x0,75SH

0 0

5

M4x0,75SH

proved wires

6

6

M5x0,75SH

laying system

18

1,5

=BCC+CC_M-X4

1.00

=BCC+ECR-X

Marine- cable

0 0

remark :

R. modification

date

date

2012-01-30

drawn

ROS

check

ROS

name standard

cable list / Kabelliste 3

Control Cabinet Boiler origin

replaced for

replaced by

0-8100-100454-14 /3-32 0-8100-100454-14-3

sheet 3 3

sh.