Water Treatment Plant Activated Carbon Filter Material of Construction: Carbon Steel Filtering Media: Activated Carbon Operating Conditions Regeneration: Every 24 hours Replacement of Filtering Media: Every 120 days Turbidity< 5 NTU Diameter = 4 m Volumetric Flow Rate = 188.65 m3/hr 𝑉 = 𝜋(𝐷2 /4)(𝐻) 188.65 m3= 𝜋(42 /4)(𝐻) H= 15.01 m Softening Unit Material of Construction: Carbon Steel Resin: Tulsion T-40 Polymer matrix: Polystyrene copolymer Physical form: Moist spherical beads Ionic form: Na+ Operating Conditions Hardness: 5ppm CaCO3 maximum Diameter = 5 m Volumetric Flow Rate = m3/hr 𝑉 = 𝜋(𝐷2 /4)(𝐻) 135.33 m3= 𝜋(52 /4)(𝐻) H= 6.89 m