Integrated Variable Refrigerant Flow AHU/PAU (R410A)
CONTENTS
Features of VRF AHU/PAU
2
WELAIRE i-GT Concept
9
VRF Outdoor Unit Performance Data
10
Drawings & Performance Data
12
Dimensions 13
Notes 14
Features of VRF AHU/PAU Designing of air conditioning system is simple, no water pump, no cooling tower and no cooling / chilled water piping Simple control system, built-in controls for VRF outdoor unit plus field installed LMCP for AHU/PAU Integrated package with VRF system Easy installation and maintenance Simple cable and refrigerant piping connection Max 224kW (80HP) cooling capacity Built-in backup, interlock and heat pump operation Long pipe run available for greater design flexibility Excellent full load COP for VRF outdoor unit (10HP) is 3.6, 50% COP is 4.3 Custom design of AHU/PAU arrangement to improve IAQ
Flexible Design Exhaust Air Fan
EX
Heat Wheel or Heat Pipe (Optional) Filter Supply Air Fan VRF AHU/PAU
OA
EEV Control Unit
RA
SA
Filter
Humidifier (Optional)
Variable Refrigerant Flow Outdoor Unit
Re-heat DX Coil (Optional)
A pair of Refrigerant Tube
one
eZ rvic
Sup
Se ply
Air
Retu r
DX Cooling Coil Variable Refrigerant Flow Outdoor Unit
n Ai
r 2
Simple Installation Compare VRF AHU to chiller plant system VRF AHU/PAU system PAU
Chiller system Pump PAU
om Machine Ro Chiller Water Tank
VRF AHU/PAU Simple Design
√
Easy Installation
√
Easy Maintenance
√
Low Running Cost
√
System Integration
√
Chiller System
Better Fresh Air Treatment Compare Custom made VRF PAU to VRF Conventional Fresh Air Pre-treated Unit
3
VRF PAU system
Traditional VRF System for Fresh Air
Up to 6,000 l/s or even more
Small air flow rate (Max. 1800l/s)
Large cooling capacity (up to 80HP)
Small cooling capacity (Max. 20HP)
Large external static pressure provided (up to 1,800Pa)
Limited external static pressure (Max. 150Pa)
Lots of IAQ options (Eg. dehumidifier, UV light, PCO, Heat pipe or heat wheel)
No space to install IAQ components
Excellent Energy Saving Compare VRF AHU to Traditional DX AHU Y SAVING ● RG E NE
3.0
with "ON/OFF" control
2.0
g
SAVING ● RGY E NE
VRF Outdoor (10HP) Outdoor with 2 scroll compressor (10HP)
4.0
gy Ener in
Sav
SAVING ● GY E ER
5.0
Y SAVING ● E RG N NE
COP
Custeosmign D
1.0 0
100%
Load %
Part Load (50%)
on & stallati ce n I y s a E nan Mainte
Comfort Temperature Control Compare VRF AHU to Traditional DX AHU - Preventive of temperature hunting Temp. Zone Temperature
Temp.
Supply air temperature is closer to setpoint Zone temperature is kept tightly near setpoint at all times by continuous load-matching operation.
Zone Temperature
Supply air temperature will be colder than needed due to excess capacity Zone setpoint is maintained by on-off cycling
Setpoint
Setpoint Time
With VRF compressor
With Scroll compressor
Time
Post-cooling unit - Improve the existing chiller plant
NEW
60mm thick double skin casing DX Cooling Coil
OLD 12°C
16°C Duct
Post-Cooling Section or Heat mode is standard provision for heating or dehumidifying
AHU
Chiller JJ JJ JJ JJ JJ JJ JJ JJ JJ JJ
r
ller system with g ch i n i t s i ooling capacity Ex ient c c i f f insu
4
Control System Compare VRF AHU to Traditional DX system - Interlock function - Duty and Standby function When AHU started operation, it If the duty AHU have fault, the activates PAU to run automatically standby AHU will be cut-in with simple wiring connection automatically in 30 seconds
AHU "ON" Automatic Mode
PAU "ON"
Alarm occured (Duty Unit)
Duty & Standby Mode
Unit "ON" (Standby unit)
AHU/PAU Timer wired remote controller
-Function ON/OFF - Mode setting - Temperature setting (AHU only) - Weekly program - Alarm history
NEW
System Controller Individual control is possible for Max. 32 AHUs. Control of 32 AHUs / PAUs individually into 4 zones. (One zone can have up to 8 units) Control is possible for ON/OFF, operation mode, operation monitoring, alarm monitoring, remote controller local operation prohibition, etc…
Serial Interface for LonWorks Network
LonWorks Interface Board
5
This interfaces is a communication converter for connecting LonWorks to the control network. From the host connected to LonWorks, basic settings of status monitoring is possible for up to 32 no. of AHU/PAU.
Simple Wiring Requirement
LonWorks Interface LON
Center Control Device (Field Supply)
LonWorks Communication Line
System Controller (Max. 64nos. AHU/PAU)
System Overview B
K C
A
A
J
Expansion valve
Remote control can be easily installed on the AHU Kit box. Remote control must be purchase separately.
Thermistor x2 (Refrigerant: E1, E3)
Thermistor x2 (x1 in PACi) (Air: Tf, Tb)
www.eggeassociats.net
AIR HANDLING UNIT KIT TO CONNECT TO YOUR VENTILATION SYSTEM 5-25 kW FOR PACi 28 kW AND 56 kW FOR ECOi AND GHP AHU CONNECTION KIT
PCB, Power trans, Terminal block
Optional parts: Following functions are available by using different type of control accessories: CZ-RTC2 Wired remote controller · Operation-ON/OFF · Mode select · Temperature setting
F
* Fan operation signal can be
without the express authorisation of Panasonic UK Ltd. warning in order to improve the product. The total or partial reproduction of this catalogue is prohibited typographic errors, and may be subject to minor modifications by the manufacturer without prior Due to the ongoing innovation of our products, the specifications of this catalogue are valid barring
taken from the PCB.
CZ-T10 terminal · Input signal= Operation ON/OFF · Remote controller prohibition · Output signal= Operating-ON status · Alarm output (by DC12 V)
G
OPTIONAL REMOTE CONTROLLER
Standard wired remote controller.
CZ-RTC2
PAW-OCT, DC12 V outlet. Option terminal · Output signal= Cool / Heat/Fan status · Defrost · Thermostat-ON CZ-CAPBC2 Mini seri-para I/O unit · Temperature setting by 0-10 V or 0-140 Ω input signal · Room (inlet air) temp outlet by 4-20 mA · Mode select or/and ON/OFF control · Fan operation control · Operation status output/ Alarm output
PRO Club Calculation software is available on www.panasonicproclub.com Or connect simply with your Smartphone to the PRO Club using this QR.
SYSTEM & REGULATIONS. SYSTEM OVERVIEW A: AHU Kit controller box (with control PCB) B: AHU Kit equipment (Field supplied) C: AHU Kit system controller (Field supplied) D: Outdoor unit F: Gas piping (Field supplied)
G: Liquid piping (Field supplied) H: Electronic expansion valve I: Thermistor for Gas pipe J: Thermistor for Liquid pipe K: Thermister for Suction air L: Thermistor for Discharge air
Technical Zoom · Maximum capacity: 60 HP (168 kW) · Maximum piping length: 180 m · Maximum total piping: 210 m · Elevation difference (in/out): 50 m (outdoor unit above) · Elevation difference (in/in): 4 m · In/Out capacity ratio: 50~100%. Maximum indoor units number: 2 units · Available temperature range in Heating: -15~15.5 °C · Available temperature range for the suction air at AHU Kit: Cool: 15~24 °C / Heat: 10~30 °C CZ-280PAH1 // CZ-280MAH1 // CZ-560MAH1 · The system controlled by the suction air (or return air from room) temperature as same as standard indoor unit. (Selectable mode: Automatic / Cooling / Heating / Fan / Dry (but same as Cool) · The discharge air temperature is also controlled to prevent too-low air discharge in Cooling or too-high air discharge in Heating. (in case · Demand control (Forcible thermostat-OFF of VRF system) control by operating current) · Defrost operation signal, Thermo-ON/OFF states output · Drain pump control (Drain-pump and the float switch to be supplied in local) · External target temperature setting via Indoor/Outdoor signal interface is available with CZ-CAPBC2. (Ex. 0 – 10 V) · Connectable with P-LINK system · Fan control signal from the PCB can be used for control the air volume (High/Mid/Low and LL for Th-off)
H
Cooling G capacity Nominal kW CZ-280MAH1 28.0 CZ-560MAH1 56.0 CZ-280MAH1 + CZ-560MAH1 84.0 CZ-560MAH1 x2 112.0 CZ-560MAH1 x2 + CZ-280MAH1 140.0 CZ-560MAH1 x3 168.0 AHU Connection Kit / System
Heating capacity Nominal kW 31.5 63.0 95.0 127.0 155.0 189.0
PACi 2-PIPE ECOi 6N SERIES
ECO G AND ECO G MULTI
To find out how Panasonic cares
28 kW (10 HP) 56 kW (20 HP) 84 kW (30 HP) 112 kW (40 HP) 140 kW (50 HP) 168 kW (60 HP) 56 kW (20 HP)
A
HP 10 20 30 40 50 60
B
E
A
L J
I K
Horsepower Cooling Airflow Bypass Factor
Dimensions of the box High / Low HxWxD m³/min mm 5,000 / 3,500 0.9 (recommended) 420 x 280 x 160 10,000 / 7,000 0.9 (recommended) 420 x 280 x 160 15,000 / 10,500 0.9 (recommended) 420 x 280 x 160 20,000 / 14,000 0.9 (recommended) 420 x 280 x 160 25,000 / 17,500 0.9 (recommended) 420 x 280 x 160 30,000 / 21,000 0.9 (recommended) 420 x 280 x 160
Combination Capacity (HP) All capacities
C E
L H
AHU CONNECTION KIT, 28 kW AND 56 kW FOR ECOi AND ECO
I
C B
H
F D G
J
I K
F D G
Piping length Elevation Pipe Diameters Intake temperature of Ambient diff. (in/out) temperature AHU Kit of outdoor unit Max Liquid pipe Gas pipe Min / Max Min / Max m Inch (mm) Inch (mm) °C °C 10 3/8 (9.52) 7/8 (22.22) Cooling:18 - 32DB Cooling: -5 - 43 DB / 10 5/8 (15.88) 1 1/8 (28.58) (13 - 23 WB) / Heating: -15 - 15.5 WB 10 3/4 (19.05) 1 1/4 (31.75) Heating:16 - 30 DB 10 3/4 (19.05) 1 1/2 (38.15) 10 3/4 (19.05) 1 1/2 (38.15) 10 3/4 (19.05) 1 1/2 (38.15)
Min / Max m 10 / 100 10 / 100 10 / 100 10 / 100 10 / 100 10 / 100
Outdoor unit combination Common use for all outdoor units Standard and Elite U-10ME1E81 U-20ME1E81 U-16ME1E81 U-14ME1E81 U-20ME1E81 U-20ME1E81 U-18ME1E81 U-16ME1E81 U-16ME1E81 U-20ME1E81 U-20ME1E81 U-20ME1E81 U-20GE2E5
AHU kit combination CZ-280PAH1 (Only 1 by 1 connection is allowed) CZ-280MAH1 CZ-560MAH1 CZ-560MAH1 CZ-280MAH1 CZ-560MAH1 CZ-560MAH1 CZ-560MAH1 CZ-560MAH1 CZ-560MAH1 CZ-560MAH1 CZ-560MAH1
E
CZ-280MAH1 CZ-560MAH1
for you, log on to: www.aircon.panasonic.e
Contact Details: Telephone: 01344 853182 Address: Panasonic Air Conditioning: / www.aircon.panasonic.eu Panasonic House // Willoughby Road // Bracknell // Berkshire // RG12 8FP
u
D
A : AHU kit controller box (with control PCB) B : AHU unit C : VRF outdoor unit D : Gas piping (field supplied) E : Liquid piping (field supplied) F : Electronic expansion valve G : Thermistor for gas pipe H : Thermistor for liquid pipe I : Thermistor for suction air J : Thermistor for discharge air K : Fan local control panel (optional)
Flexible Refrigerant piping design
Level difference between PAU/AHU & outdoor unit 50M (Outdoor unit above) 40M (Outdoor unit below) Equivalent tubing length available up to 120M
6
Optional - EC Plug Fan Transformation of Power
Comparison level for ηe(s)
Po
Features of EC Plug Fan - Compact design - Integrated assembly - Built in control - Infinitely variable speed settings - Control signal 0-10 V DC and MODBUS - Compatible with existing BMS - High energy saving potential Maintenance Aspect between Centrifugal Fan & EC Plug Fan
Centrifugal Fan
Fan Bearing Fan Shaft Belt Pulley
7
Regular greasing Potential breakage Alignment, wear & tear Alignment
EC Plug Fan
None None None None
Other Features A. Operating Range - Cooling & Heat pump mode Heating operation range: Extended heating operation range enables heating even when the outdoor temperature is as low as -25°C. Using a wired remote control, indoor heating temperature range can be set from 16°C to 30°C*.
Outside air temperature (°C WB)
-25 -20
-15
-10
-5
0
5
10
1518
Outside air temperature (°C DB)
Cooling operation range: -10°C DB to +52°C DB
-10
* Depending on the type of remote controller
-5
0
5
10
15
20
25
30
35
40
52
B. Extended compressor life by uniform compressor operation time The total run-time of compressors are monitored by a built-in microcomputer, which ensures that operation times of all compressors within the same refrigerant circuit are balanced.
Compressors with histories showing shorter run times are selected first, ensuring equal wear and tear across all units and extended the working life of the system.
System example A,C : DC inverter compressor B,D : Constant speed compressor
A B
C D
Load increase
A B
C D
Load increase
A B
C D
Load increase
C D
A B
* Depending on accumulated operation time of each compressor * Compressor priority has possibility to be changed (e.g) Case1: AACABAD, Case2: CAAADAB, Case3: AACADAB, Case 4: CAAABAD * Also other cases available
C. Automatic backup operation in the case of compressor failure or outdoor unit malfuction (Except for single unit installation) Backup operation allows uninterrupted cooling or heating to continue whist waiting for service. Users should contact their authorized service centre as soon as fault occurs.
Even if fan motor or sensor fail
X X NEW function
Even if a whole outdoor unit fails
X The other outdoor unit can keep running
Even if a compressor in a single system fails
X The other compressor can keep running
Automatic backup operation.
8
Innovative
CONCEPT
y Solution Green & Technolog
VRF Dual Coil (CHW+DX) Package Air Handling Unit Internal lining EC plug fan
DX cooling coil
Chilled water coil
Features of Dual coil design - Back-up function - Post cooling function - Dehumidity function - Light-load function
Slim Type VRF Dual Coil (CHW+DX) Package Air Handling Unit (Slim VDC AHU)
Y
DC V m
F
AHU
EC Plug Fan (Multi-fans for Water Coil Filter section standby/duty C/W 2-way (Optional) function) valve
Sli
Height in mm =650
- mini shop - Server room Length in mm = 1450(+250) Width in mm = 900
9
DX Coil C/W variable flow electrical expansion valve
VRF Outdoor Unit Performance Data (Standard Series)
HP
10
20
30
40
50
60
70
80
U-10ME2H7
U-20ME2H7
U-16ME2H7 U-14ME2H7
U-20ME2H7 U-20ME2H7
U-20ME2H7 U-16ME2H7 U-14ME2H7
U-20ME2H7 U-20ME2H7 U-20ME2H7
U-20ME2H7 U-20ME2H7 U-20ME2H7 U-10ME2H7
U-20ME2H7 U-20ME2H7 U-20ME2H7 U-20ME2H7
Model Name
380 / 400 / 415V-3-phase / 50Hz ; 380 / 400V / 3-phase / 60Hz
Power Supply kW
28
56
85
113
140
168
196
224
BTU/h
95,600
191,100
290,100
385,700
477,800
573,400
668,900
764,500
W/W
5.03
3.76
4.31
3.74
4.09
3.76
3.90
3.76
Height
mm
1,842
1,842
1,842
1,842
1,842
1,842
1,842
1,842
Width
mm
770
1,540
2,420
3,140
4,020
4,740
5,570
6,340
Depth
mm
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
Net Weight
kg
210
375
630
750
1,005
1,125
1,335
1,500
Electrical RatingsCooling
A
9.6/ 9.1/ 8.8
24.6/ 23.4/ 22.5
33.6/ 31.9/ 30.8
49.9/ 47.4/ 45.7
57.7/ 54.8/ 52.9
73.8/ 70.1/ 67.6
84.0/ 79.8/ 76.9
98.4/ 93.5/ 90.1
kW
5.57
14.90
19.70
30.20
34.20
44.70
50.30
59.6
A
1
2
4
4
6
6
7
8
m3/h
13,440
24,300
27,840
48,600
52,140
72,900
86,340
97,200
Refrigerant Amount at shipping
kg
5.6
9.5
16.6
19.0
26.1
28.5
34.1
38.0
External Static Pressure
Pa
80
80
80
80
80
80
80
80
mm
Ø22.22
Ø28.58
Ø31.75
Ø38.10
Ø38.10
Ø38.10
Ø41.28
Ø44.45
mm
Ø9.52
Ø15.88
Ø19.05
Ø19.05
Ø19.05
Ø19.05
Ø22.22
Ø22.22
mm
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Cooling Capacity
COP-Cooling
Dimension
Power Input Starting Current Airflow Rate
Gas Pipe Piping Liquid Connections Pipe Balance Pipe Ambient Temperature Operation Range Sound Pressure Level Normal Mode Sound Power Level Normal mode
Cooling : -10°C (DB)~+52°C (DB), Heating: -25°C (WB)~+18°C (WB) dB(A)
56.0
59.0
63.0
62.0
64.5
64.0
64.5
65.0
dB
77.0
80.0
84.0
83.0
85.5
85.0
85.5
86.0
10
VRF Outdoor Unit Performance Data (High Efficiency Series)
HP
10 U-10ME2H7
20 U-20ME2H7HE
30 U-30ME2H7
40 U-40ME2H7HE
50 U-50ME2H7HE
60 U-60ME2H7HE
U-10ME2H7
U-10ME2H7 U-10ME2H7
U-14ME2H7 U-16ME2H7
U-12ME2H7 U-12ME2H7 U-16ME2H7
U-10ME2H7 U-12ME2H7 U-12ME2H7 U-16ME2H7
U-12ME2H7 U-16ME2H7 U-16ME2H7 U-16ME2H7
Model Name
Power Supply
380 / 400 / 415V-3-phase / 50Hz ; 380 / 400V / 3-phase / 60Hz kW
28
56
85
113
140
168
BTU/h
95,600
191,100
290,100
385,700
477,800
573,400
W/W
5.03
5.05
4.31
4.45
4.58
4.24
Height
mm
1,842
1,842
1,842
1,842
1,842
1,842
Width
mm
770
1,600
2,420
3,660
4,490
4,900
Depth
mm
1,000
1,000
1,000
1,000
1,000
1,000
Net Weight
kg
210
420
630
855
1,065
1,215
Electrical RatingsCooling
A
9.6/9.1/8.8
19.2/18.2/17.5
33.6/31.9/30.8
42.4/40.3/38.8
51.7/49.1/47.3
66.9/63.5/61.2
kW
5.57
11.10
19.70
25.40
30.60
39.60
A
1
2
4
4
5
7
m3/h
13,440
26,880
27,840
41,760
55,200
55,680
Refrigerant Amount at shipping
kg
5.6
11.2
16.6
24.9
30.5
33.2
External Static Pressure
Pa
80
80
80
80
80
80
mm
Ø22.22
Ø28.58
Ø31.75
Ø38.10
Ø38.10
Ø38.10
mm
Ø9.52
Ø15.88
Ø19.05
Ø19.05
Ø19.05
Ø19.05
mm
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Ø6.35
Cooling Capacity
COP-Cooling
Dimension
Power Input Starting Current Airflow Rate
Gas Pipe Piping Liquid Connections Pipe Balance Pipe Ambient Temperature Operation Range
11
Cooling : -10°C (DB)~+46°C (DB), Heating: -25°C (WB)~+15°C (WB)
Sound Pressure Level Normal Mode
dB(A)
53.0
59.0
63.0
63.5
64.5
66.5
Sound Power Level Normal mode
dB
74.0
80.0
84.0
84.5
85.5
87.5
Drawings
H W
L
Performance Data AHU Performance Data AHU Model No.
A1-1170H-1050W A1-1450H-1350W A1-1770H-1650W A1-1770H-1950W A1-1930H-2250W
A1-2250H-2250W
VRF Outdoor Model No.
U-10ME2H7 U-20ME2H7 U-16ME2H7 U-14ME2H7 U-20ME2H7 U-20ME2H7 U-20ME2H7 U-16ME2H7 U-14ME2H7 U-20ME2H7 U-20ME2H7 U-20ME2H7
3
m /s
mm
mm
mm
°C/%
°C
System Cooling Capacity kW
1.49 2.90
1,210 1,550
1,050 1,350
1,595 1,595
25/55 25/55
12.5 12.5
28 56
4.47
1,870
1,500
1,595
25/55
12.5
85
5.92
1,870
1,950
1,900
25/55
12.5
113
7.45
2,030
2,250
2,205
25/55
12.5
140
8.94
2,250
2,250
2,205
25/55
12.5
168
On Coil
Off Coil
DB/RH
DB
AHU Air flow rate
Standard Unit Dimensions Height
Width
Length
On Coil
Off Coil
DB/RH
DB
PAU Performance Data PAU Model No.
A1-830H-1050W A1-850H-1050W A1-1170H-1050W A1-1170H-1350W A1-1330H-1350W
A1-1330H-1650W
VRF Outdoor Model No.
U-10ME2H7 U-20ME2H7 U-16ME2H7 U-14ME2H7 U-20ME2H7 U-20ME2H7 U-20ME2H7 U-16ME2H7 U-14ME2H7 U-20ME2H7 U-20ME2H7 U-20ME2H7
3
m /s
mm
mm
mm
°C/%
°C
System Cooling Capacity kW
0.50 1.00
950 950
985 985
1,595 1,595
35/70 35/70
15 15
28 56
1.50
1,430
985
1,595
35/70
15
85
2.00
1,430
1,290
1,595
35/70
15
113
2.50
2,030
1,290
1,900
35/70
15
140
3.00
2,030
1,595
2,205
35/70
15
168
AHU Air flow rate
Standard Unit Dimensions Height
Width
Length
Remarks: 1. Height does not include the unit base 100mm* 2. Standard length include coil and fan, external mounted per filter is 50mm** 3. Specifications are subjected to change without prior notice.
12
Dimensions (Standard Series) 10 HP U-10ME2H7 Air Outlet Installation anchor hole 8-15x21 elongated holes
A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch) 1842 953
A:964 18
B: 730
740 770
C:730
Air intake
Air intake
1000
Air intake
15
Top View
Front View
14-16 HP U-14ME2H7 U-16ME2H7
According to the installation site, you may choose the setting positionin the depth direction of the anchor bolt from A, B or C.
Air Outlet
Installation anchor hole 8-15x21 elongated holes
A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch)
1150 1180
1842 953
C:730 Air intake B: 730 18 A:964
1000 Air intake
Air intake
15
Top View
Front View
20 HP U-20ME2H7 Air Outlet
1510 1540 Top View
According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C.
1842
A: (Installation hole pitch) For removing tube forward B: (Installation hole pitch) For removing tube downward C: (Installation hole pitch) 953
C:730 Air intake B:730 A:964 18
1000
Air intake
Installation anchor hole 8-15x21 elongated holes Air intake Air intake 740
15
According to the installation site, you may choose the setting positionin the depth direction of the anchor bolt from A, B or C.
Front View
Unit in mm 13
Dimensions (High Efficiency Series) 10 HP U-10ME2H7 According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A (Installation hole pitch) For removing tube forward B (Installation hole pitch) For removing the downward C (Installation hole pitch) Top view
Front view
Installation anchor hole, 8-15x21 elongated holes Air Intake
Air outlet
B:730
1000
A:964 C:730
Air Intake
Air Intake
15
740 770
18
1842 953
12/14/16 HP U-12ME2H7 U-14ME2H7 U-16ME2H7 According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C. A (Installation hole pitch) For removing tube forward B (Installation hole pitch) For removing the downward Air outlet C (Installation hole pitch) Installation anchor hole, 8-15x21 elongated holes Air Intake
Air Intake B:730 1000
C:730
A:964 Air Intake
1842 953
15
1150
18
1180
Top view
Front view Unit in mm 14
SAIVER S.R.L
Via M. da Besozzo, 16 20052 Monza (Milan) Italy. Tel : +39. 039. 282 831 Fax : +39. 039. 202 5668 E-mail :
[email protected] Website: www.saiver.com 219mmx64mm
SAIVER – Pantone: 2925C