Guangzhou Kangzhen Medical Equipment Co., Ltd http://www.kzmedical.com
1. INTRODUCTIONS OF THE PRODUCTS 1) The Whole Computer Controlled Ozone Disinfector THEME BASIS Keeping the hospital environment infection free is a prime concern of any
conscientious hospital management. Preventing contamination and spread of infection is an assigned responsibility of the doctors and nurses, which can never be compromised. The most common cause of high internal rate of infection in a hospital is the poor sanitization of the beddings (sheets, pillows, mattresses etc) and the clothing used by the patients. Till now, the most commonly used methods of sanitizing bed sheets , mattresses ,
pillows ,
etc. have been ultra-violet radiation and
utilization of highly compressed steam. These methods can, at best, disinfect the surfaces but have not been so effective in eradicating the deep rooted pathogens. Guangzhou Kangzhen Medical Appliance Co. Ltd., following many years of extensive research, has developed KZ-X-DLI model of fully computer controlled ozone disinfector. This disinfector can be an excellent facility for cross-infection control and sanitization. It can root-out infection most
economically and effectively prevent the spread of diseases in a hospital environment. The ozone disinfector is the latest equipment of its kind and has been listed in the Disinfection Technical Standards published by the Department of Health in 2002. This ozone disinfection is now the only assigned method of sterilization.
PRODUCT FEATURES 1.
Safe, reliable, efficient and effective in disinfection.
2. Kill bacterium and vermin eggs etc. just in2-6minutes normally. 3.
Excellent effect of deodorization, gout and stain elimination.
4.
Can dispel inorganic and organic pollutants, as well as toxicant.
5.
Small size, easy to operate, convenient to move, and it can be put beside the sickbed and disinfect the beddings and the air of the room directly.
6 . With vacuum disinfecting and ozone decomposing functions, the equipment can disinfect more effectively, which has been granted by the national patent. 7 . It has adopted the most advanced technology of BNP titanium-ceramic structured ozone generator, which can generate large amount of ozone, and the lowest output of ozone can reach 7g/h, and its working life is as 3 times as the other average ozone generators. In addition, this ozone disinfector carries a 10-year warranty.
8.The interior of the disinfector has a huge powerful stainless steel electromagnetic valve which mean reduced equipment downtime. 9 . Fully sealed model which prevent any ozone leakage from the equipment can ensure the safety of both patient and hospital staff. 10 . The additional ozone degradation function, which has been granted structure patent can decompose the ozone remained, which can prevent the pollution of environment. 11 . It is unique in China that can disinfect 3 beds at the same time, which has increase the efficiency of bedding disinfection, and solve out the problem of bed shortage in hospital obviously. 12. It can apply to the clothing sterilization of staff in operating rooms other than bedding disinfection. 13. It is unique in China that has total digital command and automatic function. The whole operation process is just to press one key, and then it would enter four disinfection
steps:
vacuum,
disposal-ozone
,generating-maintain,ozone
decomposition. It is easy to use and no need to watch for.
INDICATION The ozone disinfecting equipment can be applied to the bedding disinfection in hospitals and hotels, which includes the disinfection of mattresses; bed clothes,
carpet, pillow fillers and bed sheets and so on. In addition, it can also be applied for air sterilization in office; laboratory, meeting room, etc.
DIRECTION 1. Put the mattresses, bed clothes, bed sheets, pillows, etc. into the sealed plastic disinfection bags and then connect the gas transport pipes. 2.
Turn on the power button ON. Then choose the disinfecting time, from 20 to 30 minutes. Last, press the thin film switch ON, and then the equipment would begin to work. Count down the time, and when the clock reaches 00, the disinfecting operation has finished.
3.
After finishing the disinfecting operation, the equipment would ring. After that, take off the gas transport pipes, and insert the plug of the disinfection cover, and keep the ozone in the disinfection cover for around 30 minutes.
Technology Criteria
1. Minimum ozone working concentration: 2. Minimum ozone generated: 3. Noise:
7g/h
<40db
4. Operation voltage:
220V 50Hz
800mg/m3
5. Rating power:
200W
6. Output pressure: 6kpa
Clinical Trial Virus & bacteria genus Candida albicans
killing rate 99.96%
Staphylococcus aureus
99.97%
Pseudomonas aeruginosa Escherichia coli
99.98% 99.97%
Organism influence test: Colibacillus
99.97%
HBsAG breaking test
negative
SPECIFICATION Size (mm)
Weigh
Noise
Minimum Ozone Output
length*width*height
36 kg
< 40 db
7 g/h
433*442*1040
Minimum Ozone Working Concentration 800 mg/m3
Pattern
KZ-X-DL1 Vacuum ozone decompositio n type
Disinfection Methods Sealed Disinfecti on Bag mode.
Main Function
*Adaptable to thorough disinfection of beddings; *No ozone leakage; *With decomposition of remaining ozone function, and do not pollute the environment.
MAJOR TECHNOLOGY CRITERIA Comparing with other internal and external similar advanced technology
KangZhen product technology
Other products technology
KZ. Whole Computer Controlled Ozone Disinfector 1. With vacuum disinfection function, the ozone disinfector can disinfect beddings thoroughly and effectively. 2. The disinfector has adopted the most advanced technology of BNP titanium-ceramic structured ozone generator, and the lowest ozone output can reach 7g/h, whose working life is as 3 times as the other average ozone generators. 3. Fully sealed model which prevent any ozone leakage from the equipment can ensure the safety of both patients and hospital staff.
Ozone Disinfector Without vacuum disinfection function, ozone can not penetrate through the beddings, which can only disinfect the surface. Adopted the general porcelain mode of ozone generator, short working life, and must be replaced after working for 5 000 hours. The lowest ozone output is about 3g/h, and its working life is about 3 years Only adopt the piece mode disinfecting bed cover to disinfect beddings, which is only semi-sealed. So there will be ozone leakage from the bed, which will influence the patients and staff around. No such function.
4. The additional ozone degradation function, which has been granted structure patent can decompose the ozone remained, which can prevent the pollution of environment. 5. It can apply to the clothing sterilization of staff Only disinfect the surface of beddings. in hospital other than bedding disinfection. 6. It is unique in China that can disinfect 3 beds at Only can disinfect 2 beds at the same time. the same time, which has increase the efficiency of bedding disinfection, and solve out the problem of bed shortage in hospital obviously. 7. The interior of the disinfector has a huge Adopt the copper electromagnetic valve powerful stainless steel electromagnetic valve interior only, which can be easily etched by the which mean reduced equipment downtime. ozone, and must be replaced after one year. 8. It is unique in China that has total digital The whole disinfection process just includes command and automatic function. The whole two steps: ozone generating & maintain, which operation process is just to press one key, and can only disinfect the surfaces. Moreover, there then it would enter four disinfection steps: will be ozone leakage during the disinfecting vacuum disposal-ozone generating-remain-ozone process, which will etch the oxygen pipes in decomposition. the ward, and influence the patients and staff around.
2. The National & International Ozone Disinfection Clinical Trial Data Ozone Concentration
Disinfecting
Species
Time
(virus &
Reduction in number of live microorganisms
pathogen) 10mg/m3 0.5ppm 0.13mg/L 40µg/L 0.25mg/L 4mg/L 8mg/ m3
20 min 5 min 30 seconds 20 seconds 1 min 3 min 10 min
HbsAg Influenza A virus PV1 Coli Phage ms2 SA-H HIV Mycoplasma, Chlamydia & any other pathogens
99.99% 99% 100% 98% 99.60% 100% 99.85%
3. OZONE DISFINFECTION MECHANISM The disinfection function of ozone belongs to a biochemistry oxidization reaction. Because of its high oxidation potential, ozone oxidizes cell components of the bacterial cell wall. This is a consequence of cell wall penetration. Once ozone has entered the cell, it oxidizes all essential components (enzymes, proteins, DNA, RNA). When the cell membrane is damaged during this process, the cell will fall apart. This is called lysis,
see
figure
1
below.
The above-mentioned mechanism differs from that of halogens (such as chlorine), which are usually applied. Chlorine is known to penetrate cells by diffusion. Within the cell, chlorine affects several enzyme types.
Figure 1: Bacterial lysis by ozone in 6 steps (see below)
Ozone disinfection steps: 1 – Computer animation of a bacterial cell 2 – Close-up of an ozone molecule on the bacterial cell wall 3 – Ozone penetrates the cell wall and causes corrosion 4 – Close-up of the effect of ozone on the cell wall 5 – Bacterial cell after it has come in contact with a number of ozone molecules 6 – Cell destruction (lysis) 4. SAFETY OF OZONE DISINFECTION Ozone is a safe gas that treats the environment friendly. And its only
toxicity is from its high oxidation potential. When the ozone concentration reaches 1.55ppm or up, people should not be allowed to stay around, because ozone is injurious to the breathing system of human body when it’s serious. Therefore, the ozone industrial associations have set health standard as follows:
International Ozone Association:
0.11ppm—approach—10 hours
United States of America:
0.1ppm—approach—8 hours
Germany/France/Japan, etc:
0.1ppm—approach—10 hours
China:
0.15ppm—approach—8 hours
Above are standards for keeping people in an ozone environment safely. Ozone concentration multiplied by its approach time can be seen as its standard point. As it’s reported that when ozone concentration reaches to 0.02ppm, people with sensitive smell can perceive it, which is called felling edge point; when the ozone concentration reaches to 0.15ppm, it’s called smell edge point, at which the ozone can be smelt by average people, and it is also known as the healthy standard point; in addition, when the ozone concentration reaches 1-10ppm, it is called the stimulation scope; when the concentration is above 10ppm, it is the point of poisonous edge. In fact, applying ozone appropriately can prevent
people from suffering. Instead, it is good for human when the ozone concentration is less than 0.1ppm in an environment. Ozone has been applied for more than 100 years. So far, there’s no one case reported that somebody was poisoned by ozone.