Test Report

  • Uploaded by: Cory Brown
  • 0
  • 0
  • July 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Test Report as PDF for free.

More details

  • Words: 1,122
  • Pages: 5
TEST REPORT

NUMBER : TRPT09042571 DATE : 02-Dec-2009

Applicant: S.R.P FASHIONS 5/77, S.R.P GARDEN, AVINASHILINGAM PALAYAM,,TIRUPUR ROAD.,AVINASHI,INDIA,Attn : Jeena, Ms.Aarthi, P.MURUGAN. Tested On Behalf Of S.R.P FASHIONS To BHS Standard (CH 09) By Intertek India Private Limited, Laboratory Cerificate Number 2004/050 Sample Identification : Buyer :BHS/UK Style No./CAT No.

:BHS 4278

Fabric Supplier : S.R.P FASHIONS Fabric Quality Colour

: :WHITE ,

Description : FOUR PIECES OF SUBMITTED KNITTE ROUND NECK TOP SAMPLE WITH PRINT AND BOW AT FRONT, RIB AROUND NECK, PIPING ALONG BACK NECK, MARKED AS WHITE. Date Received :02- Dec- 2009 Date Completed :02- Dec- 2009 Date Test Started :02- Dec- 2009 Applicant Provided Wash Care Instruction:-

Ref.:

Order No. : 36970 Agent's Name : PRAMOD KNIT FASHION [LDL] Manufacturer's Name: S.R.P FASHIONS

PREPARED & CHECKED BY : FOR INTERTEK INDIA PRIVATE LIMITED [TIRUPUR]

ASHOK L LAB MANAGER TEX-130

Intertek India Private Limited

Page 1 of 5

Aristo International Building,No.10, Mahaveer Colony,Sababathipuram, Tirupur-641601. Tel : 91-421- 430 6600, Fax : 91-421-223 2800 Registered Office : G3, Ground Floor, Akruti Corporate Park, LBS Marg, Opp: Naval Civilian Housing Colony, Kanjurmarg (West), Mumbai – 400 079 Tel : +91-22-67976900., Fax : 91-22-5503 1087 Web site : www.intertek-labtest.com.

TEST REPORT

NUMBER : TRPT09042571 DATE : 02-Dec-2009

Test Requested : As requested by the applicant, selected test(s) to the standard were conducted. For details please see the following page(s). Fibre Content : Fibre Content : Comments On Test Results : THE SUBMITTED SAMPLE FAILS TO MEET THE BUYER'S REQUIREMENT IN DURABILITY WASH, GARMENT CLEANSING, MULTIPLE WASH OF GARMENTS AND SECURITY OF ATTACHMENT

TEX-130

Intertek India Private Limited

Page 2 of 5

Aristo International Building,No.10, Mahaveer Colony,Sababathipuram, Tirupur-641601. Tel : 91-421- 430 6600, Fax : 91-421-223 2800 Registered Office : G3, Ground Floor, Akruti Corporate Park, LBS Marg, Opp: Naval Civilian Housing Colony, Kanjurmarg (West), Mumbai – 400 079 Tel : +91-22-67976900., Fax : 91-22-5503 1087 Web site : www.intertek-labtest.com.

TEST REPORT

NUMBER : TRPT09042571

TEST CONDUCTED (AS REQUESTED BY THE APPLICANT) Bhs Test No Test Garment Cleansing Test 9P (WASCATOR WASHING MACHINE-FRONT-LOADING HORIZONTAL ROTATING DRUM TYPE, TEST NO.6A, AT 40ºC, 48g OF IEC REFERENCE DETERGENT AND 12g OF SODIUM PERBORATE SOLUTION FOLLOWED BY LINE DRY WITH COOL IRON) Base/Rib COLOUR CHANGE [WITHOUT SUPPRESSOR] COLOUR CHANGE [WITH SUPPRESSOR] MULTIFIBRE STAINING SELF STAINING OBSERVATION . . . . . . . . . . . .

4 MIN 4-5 4-5 4-5

4-5 MIN NO OTHER SIGNIFICANT CHANGE

Slight Colour Change Of Base/Rib Was Observed On The Washed Garment. Slight Fuzzing Effect Was Observed. No Pilling Was Found. Slight Seam Puckers Were Observed On The Washed Garment. No Side Seam Distortion And 0° Spirality Was Observed No Detachment Of Decorative Stones/Bow Was Observed No Seam Opening/Breakage Was Observed. Noticeable Fraying Of Applique Was Observed On The Washed On The Raw Edges Around The Applique No Removal/Cracking Of Other Print Was Observed On The Washed Garment Moderate Removal Of Foil Print Was observed Moderate Loss Of Glossy Effect Was Observed On The Foil Print No Obvious Shape Deterioration Was Observed On The Washed Garment

Print/Applique/Piping/Bow COLOUR CHANGE [WITHOUT SUPPRESSOR] COLOUR CHANGE [WITH SUPPRESSOR]

TEX-130

REQUIREMENT

4-5

REQUIREMENT

4 4 MIN 4

Intertek India Private Limited

Page 3 of 5

Aristo International Building,No.10, Mahaveer Colony,Sababathipuram, Tirupur-641601. Tel : 91-421- 430 6600, Fax : 91-421-223 2800 Registered Office : G3, Ground Floor, Akruti Corporate Park, LBS Marg, Opp: Naval Civilian Housing Colony, Kanjurmarg (West), Mumbai – 400 079 Tel : +91-22-67976900., Fax : 91-22-5503 1087 Web site : www.intertek-labtest.com.

TEST REPORT

NUMBER : TRPT09042571

TEST CONDUCTED (AS REQUESTED BY THE APPLICANT) Bhs Test No Test MULTIPLE WASH OF GARMENTS WITH EMBLISHMENT: [12F] BHS TEST METHOD 12F (WASCATOR WASHING MACHINE-FRONT-LOADING HORIZONTAL ROTATING DRUM TYPE, TEST NO.6A, AT 40ºC, WITH 2KG LOAD, IN 160g OF IEC REFERENCE DETERGENT AND 40g OF SODIUM PERBORATE SOLUTION FOLLOWED BY FLAT DRY WITH COOL IRONING) Base/Rib COLOUR CHANGE SELF STAINING OBSERVATION . . . . . . . . . . . . . . . .

4-5 4-5

SATISFACTORY

No Yellowing Effect Of Base/Rib Was Observed Noticeable Colour Change Of Red Print Was Observed Moderate Colour Change Of Print (Others) Was Observed Slight Colour Change Of Piping/Applique/Bow Was Observed On The Washed Garment Slight Fuzzing Effect Was Observed No Pilling Was Found. Slight Seam Puckers Were Observed On The Washed Garment. Slight Spirality Was Observed. No Detachment Of Bow Was Observed No Seam Opening/Breakage Was Observed. Severe Fraying Was Observed On The Untrimmed Raw Edges Around The Applique No Detachment Of Decorative Stones Was Observed Red Print Has Been Washed Off Noticeably Print (Others) Has Been Washed Off Moderately Complete Removal Of Foil Print Was Observed No Obvious Shape Deterioration Was Observed On The Washed Garment Print (Red)

COLOUR CHANGE

REQUIREMENT

REQUIREMENT

3 SATISFACTORY Print (Others)

COLOUR CHANGE

REQUIREMENT

3-4 SATISFACTORY Piping/Applique/Bow

COLOUR CHANGE

REQUIREMENT

4 SATISFACTORY

TEX-130

Intertek India Private Limited

Page 4 of 5

Aristo International Building,No.10, Mahaveer Colony,Sababathipuram, Tirupur-641601. Tel : 91-421- 430 6600, Fax : 91-421-223 2800 Registered Office : G3, Ground Floor, Akruti Corporate Park, LBS Marg, Opp: Naval Civilian Housing Colony, Kanjurmarg (West), Mumbai – 400 079 Tel : +91-22-67976900., Fax : 91-22-5503 1087 Web site : www.intertek-labtest.com.

TEST REPORT

NUMBER : TRPT09042571

TEST CONDUCTED (AS REQUESTED BY THE APPLICANT) Bhs Test No Test DURABILITY WASH [ DURAWASH AT 50°C, FOLLOWED BY FLAT DRY] Base/Rib SATISFACTORY COLOUR CHANGE SELF STAINING . . . . . . . . . . .

4-5 4-5 No Yellowing Effect Of Base/Rib Was Observed Noticeable Colour Change Of Print (Red) Was Observed Moderate Colour change Of Print (Others) Was Observed Slight Colour Change Of Piping/Applique/Bow/Print (Pink) Was Observed Severe Fraying Of Applique Was Observed On The Untrimmed Raw Edges Around The Applique Print (Red) Has Been Washed Off Noticeably Print (Others) Has Been Washed Off Moderately No Removal/Cracking Of Print (Pink) Was Observed Complete Removal Of Foil Print Was Observed Slight Self Staining Was Observed No Detachment Of Bow/Decorative Stones Was Observed Piping/Applique/Bow/Print (Pink) SATISFACTORY

COLOUR CHANGE

4 Print (Others) SATISFACTORY

COLOUR CHANGE

3-4 Print (Red) SATISFACTORY

COLOUR CHANGE

3

SECURITY OF ATTACHMENT TEST METHOD 17 SPECIMEN NO. 1. 2. 3. 4. 5. 6.

INDIVIDUAL READINGS 85.9 N [FR]* 84.2 N [FR]** 80.5 N [FR]** 72.3 N [FR]** 81.1 N [FR]** 84.2 N [FR]**

90 N

REMARK: FR = Fabric Rupture * Garment Front ** Mock Up Sample ## END OF THE TEST REPORT ##

TEX-130

Intertek India Private Limited

Page 5 of 5

Aristo International Building,No.10, Mahaveer Colony,Sababathipuram, Tirupur-641601. Tel : 91-421- 430 6600, Fax : 91-421-223 2800 Registered Office : G3, Ground Floor, Akruti Corporate Park, LBS Marg, Opp: Naval Civilian Housing Colony, Kanjurmarg (West), Mumbai – 400 079 Tel : +91-22-67976900., Fax : 91-22-5503 1087 Web site : www.intertek-labtest.com.

Related Documents

Test Report
June 2020 9
Test Report
June 2020 4
Test Report
July 2020 7
Test Report
October 2019 19
Test Report
May 2020 3
Bs Oil Test Report
June 2020 7

More Documents from "viswam"