SPECIFICATION N O 1.
2.
ELEMENTS Substructure Work Below Lowest Floor Finish Superstructure Frame Roof External wall Window and external door Internal wall and partition Internal door
3.
Finishes Internal wall finishes Internal floor External finishes
4. 5.
Fittings and furnishing Services Electrical installation Plumbing installation Sanitary Appliances
6.
Fire protection External work Timber decking Steps
SPECIFICATION Pad footings, pile cap, column stump, RC grade 30 ground beams, ground floor slab, water proofing membrane, formwork RC grade 30 columns, beams and roof beams Timber roof trusses and clay roof tiles with layer of insulation and sisalation soil, gutter and RWDP, fascia board. Generally 115mm thick half brickwall, plastered with cement and sand, damp proof course Solid timber flush door, decorative timber flush door, sliding door, timber casement window with timber louvers with full sets of ironmongeries Generally 115mm thick half brickwall, plastered with cement and sand Solid timber flush door complete with sets of ironmongeries, PVC door Cement and sand plastering with emulsion paint generally 1.8m high glazed ceramic tiles to toilet, timber wall finishes Timber strips or unglazed ceramic tiles, homogenous tiles to toilet, cement and sand paving. Weather shield paint, timber coat and varnish. Referred to Interior Design’s works Electrical supply and fittings Soil, waste, and ventilation pipe system, cold water services storage water tank. Water closet; wash basin and other sanitary ware Fire extinguishers Timber decks Timber steps
7. 8.
Landscape Preliminaries
Referred to Landscape Architect’s Drawings Referred to Landscape Architect’s Drawings