Special Purpose Fuses Special Purpose Fuses European Fuses Residential Fuses gF/gG
Reference Numbers, Ratings – gF/gG (Optional Blown-Fuse Indicator) Size Rated In Rated (mm x mm) Current (A) Voltage
J218186
X213092
V214608
Q222953
D215122
W217162
w/Indicator
6kA - 250V FR623GF25V2 FR623GF25V4 FR623GF25V6 FR623GF25V10
N213590 Q214098 T214607 D215628
2 4 8.5 X 23 6 NF 10* 15
250V
10213 10219 10223 10231 10235
12213 12219 12223 12231 12235
K216140 H216644 V217161 J218186 K219222
6 10 16*
250V
10423 10431 10435
12423 12431 12435
M219753 S214100 6kA - 250V FR1025GF25V6 FR1025GF25V6I FR1025GF25V10 FR1025GF25V10I V222198 W214609 FR1025GF25V16 FR1025GF25V16I Q222953 D215122
0.5 1 2 4 6 8.5 x 31.5 8 10 12 16 NF 20* 25
380V
10609 10611 10613 10619 10623 10627 10631 10633 10635 10637 10639
12609 12611 12613 12619 12623 12627 12631 12633 12635 12637 12639
N201285 Y201800 V211020 M211542 T212054 L212576 W213091 P213591 R214099 V214608 E215629
16 20 25*
380V
10835 10837 10839
12835 12837 12839
L216141 A201802 20kA - 400V FR1031GF38V16 FR1031GF38V16I FR1031GF38V20 FR1031GF38V20I J216645 X211022 FR1031GF38V25 FR1031GF38V25I W217162 P211544
2 4 6 10 16 20 25 32
380V
11013 11019 11023 11031 11035 11037 11039 11043
13013 13019 13023 13031 13035 13037 13039 13043
A217672 K218187 Y218705 L219223 N219754 W222199 R222954 A200744
25 32*
380V
11239 11243
13239 13243
P201286 L216647 20kA - 400V FR1038GF38V25 FR1038GF38V25I Z201801 Y217164 FR1038GF38V32 FR1038GF38V32I
6 X 23
NF
10.3 X 25.8
10.3 x 31.5
Z201801
10.3 x 38
4 5 6 7
Catalog Number w/o Indicator
-
8.5 x 36
Ceramic body Sand Indicator contact Lower contact Contact ring Melting element Indicator
Breaking capacity
10013 10019 10023 10031
P211544
1 2 3
w/Indicator
250V
NF
Y217164
Reference Number
w/Indicator w/o Indicator
2 4 6* 10
NF
B200745
Previous Ref. w/o Indicator
NF
-
N211543 6kA - 250V V212055 M212577 X213092 Q213592
K216646 X217163 B217673 L218188 Z218706 M219224 X222200 B200745 Q201287
FR823GF25V2 FR823GF25V4 FR823GF25V6 FR823GF25V10 FR823GF25V16
20kA - 400V FR831GF38V0.5 FR831GF38V1 FR831GF38V2 FR831GF38V4 FR831GF38V6 FR831GF38V8 FR831GF38V10 FR831GF38V12 FR831GF38V16 FR831GF38V20 FR831GF38V25
N212578 20kA - 400V Y213093 R213593 T214101 X214610 E215123 G215631 N216143
FR836GF38V2 FR836GF38V4 FR836GF38V6 FR836GF38V10 FR836GF38V16 FR836GF38V20 FR836GF38V25 FR836GF38V32
FR823GF25V2I FR823GF25V4I FR823GF25V6I FR823GF25V10 IFR823GF25V16I
FR831GF38V2I FR831GF38V4I FR831GF38V6I FR831GF38V8I FR831GF38V10I FR831GF38V12I FR831GF38V16I FR831GF38V20I FR831GF38V25I
FR836GF38V2I FR836GF38V4I FR836GF38V6I FR836GF38V10I FR836GF38V16I FR836GF38V20I FR836GF38V25I FR836GF38V32I
* Produits homologués Packaging: 10 pieces
Dimensions Fuze Size (mm x mm) 6.3 8.5 10.3 8.5 10.3 8.5 10.3
x x x x x x x
23 23 25.8 31.5 31.5 36 38
A
B
C
6.3 8.5 10.3 8.5 10.3 8.5 10.3
23 23 25.8 31.5 31.5 36 38
5 5 6.3 6.3 10 6.3 10
Blown-Fuse Indicator
Before SP2
After 12/04
Special Purpose Fuses Special Purpose Fuses European Fuses Residential Fuses gF/gG
TIME IN SECONDS
MELTING TIME - CURRENT DATA – 2-16 AMPERES, 250V
CURRENT IN AMPERES
TIME IN SECONDS
MELTING TIME - CURRENT DATA – 2-32 AMPERES, 380V
CURRENT IN AMPERES
12/04
SP3
Special Purpose Fuses Special Purpose Fuses European Fuses Residential Fuses aD
A B C
Size
In (A)
10 x 38 10,3 38 10,5
Previous Ref
14 x 51 14,3 51 13,8
22 x 58 22,2 58 16,2
Ref. Number
Icc-Vn
Pack.
Cat. Number
AD: In max: 90A; Vn max: 440V
K201305
10 x 38
AD 15
16134
V216149
20KA-440V
10
10AD44V15
14 x 51
AD 15 AD 30
17134 17141
E222966 M200755
32KA-440V 32KA-440V
10
14AD44V15 14AD44V30
AD AD AD AD
15 30 45 60
18134 18141 18149 18153
M222973 V200762 K201305 T201819
32KA-440V
10
22AD44V15 22AD44V30 22AD44V45 22AD44V60
AD AD AD AD AD
15 30 45 60 90
37134 37141 37149 37153 37161
J223430 P223435 X223442
32KA-440V
10
00AD44V45 00AD44V60 00AD44V90
19100
R211569 L228032 M228033
10
FRN1038 FRN1451 FRN2258
W216058
10
NH00NEUTRAL
22 x 58
Neutral 00
P223435 10 x 38 14 x 51 22 x 58 00
Standards: EDF HN 62-S-83
SP4
12/04
Special Purpose Fuses Special Purpose Fuses European Fuses Residential Fuses Disconnector MSD Disconnector 78 59
5
45
78
• Blown-fuse indicator (120/690V) • Cable size: - Unipolar: 1 x 16 mm 2 - Unipolar + neutral: 1 x 10 mm 2 • IP20
2,5 12,5
42,5 17,5
MSD: in maxi. 32A - Vn maxi. 400 V Previous Ref. Size
Poles
1
1+N (1 mod.)
8 x 23 10 x 25 8 x 31 10 x 31 10 x 38 N 8 x 23 10 x 25 8 x 31 10 x 31 10 x 38
Reference Number
+ + Standard Indicator Standard Indicator
13502 13602 13702 13802 13902 14000 13506 13606 13706 13806 13906
13504 13604 13704 13804 13904 13508 13608 13708 13808 13908
Catalog Number In-Vn Standard
C217674 A218707 10A-250V MSD8231 R201288 Y211023 16A-250V MSD10251 V214102 F215124 20A-400V MSD8311 N218190 P219226 25A-400V MSD10311 S201289 Z211024 32A-400V MSD10381 MSDN W214103 N219225 T222956 10A-250V MSD8231N Q211545 Z213094 16A-250V MSD10251N H215632 Z217165 20A-400V MSD8311N R219757 V222957 25A-400V MSD10311N R211546 A213095 32A-400V MSD10381N
+ Indicator
MSD823I MSD10251I MSD831I MSD1031I MSD1038I MSD8231NI MSD10251NI MSD8311NI MSD10311NI MSD10381NI
P219226
N219225
Packaging: 12 pieces
Assembly pin N. Mod.
Previous Ref.
Reference Number
Catalog Number
2 3 4
14030 14031 14032
G215125 Q216145 A217166
MSCMSDMAASS2 MSCMSDMAASS3 MSCMSDMAASS4 J225707
Packaging: 10 pieces
Approvals: IEC 269-3-1, NFC 61.201 Approvals: NF/USE (MSD)
12/04
SP5
Special Purpose Fuses Special Purpose Fuses European Fuses DIN Forklift Fuses CNN DIN, CNL
Ferraz Shawmut is launching a brand-new range of fuses for protecting batteries. It had been developed for meeting very severe uses. These fuses are packaged by 5 in carton box. They can be fitted on FBT fuse bases as per DIN 43 560 fuse dimensions Voltage (V)
32VAC/DC Breaking capacity = 2500A
Current (A) 35 40 50 60 80 100 125 130 150 175 200 225 250 275 300 325 350 400 500
Reference Number T216332 L217360 A218385 E219424 Y219947 K201995 K211218 A211738 J212252 W212769 J213287 A213785 J214299 J214805 L215313 P215822 X216841 T217873 Q218905 A092092
Catalog Number CNL35 DIN CNL40 DIN CNL50 DIN CNL60 DIN CNL80 DIN CNL100 DIN CNL125 DIN CNL130 DIN CNL150 DIN CNL175 DIN CNL200 DIN CNL225 DIN CNL250 DIN CNL275 DIN CNL300 DIN CNL325 DIN CNL350 DIN CNL400 DIN CNL500 DIN SFBT
Rating (A) 10 35 40 50 60 80 90 100 125 150 175 180 200 225 250 275 300 325 350 400 500 600 700 800
Reference Number E228831 F228832 G228833 H228834 J228835 K228836 L228837 M228838 N228839 P228840 Q228841 N229874 R228842 S228843 T228844 V228845 W228846 X228874 Y228848 Z228849 A228850 B228851 C228852 D228853 A092092
Catalog Number CNN10 DIN CNN35 DIN CNN40 DIN CNN50 DIN CNN60 DIN CNN80 DIN CNN90 DIN CNN100 DIN CNN125 DIN CNN150 DIN CNN175 DIN CNN180 DIN CNN200 DIN CNN225 DIN CNN250 DIN CNN275 DIN CNN300 DIN CNN325 DIN CNN350 DIN CNN400 DIN CNN500 DIN CNN600 DIN CNN700 DIN CNN800 DIN SFBT
Fuse base Voltage (V)
130VAC/AC 75VAC/DC Breaking capacity = 2600A@75VAC DC
130VAC/AC 48VAC/DC Breaking capacity = 2600A@48VAC DC Fuse base
A
Dimensions CNLDIN CNNDIN
A mm
B mm
C mm
D mm
E mm
82
60
23 max
20
11
D
E
B
* Thickness: 11 mm max
SP6
12/04
Special Purpose Fuses Special Purpose Fuses European Fuses DIN Forklift Fuses CNN DIN, CNL
TIME IN SECONDS
MELTING TIME – CURRENT DATA – CNL35–500
CURRENT IN AMPERES
TIME IN SECONDS
MELTING TIME – CURRENT DATA – CNN10–800
CURRENT IN AMPERES 12/04
SP7
Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses
PROTECTION AGAINST LOW VOLTAGE ARRESTER FAILURE When an arrester fails (it can no longer contain overvoltage and thus short circuits), a fuse is needed to prevent its explosion. If the fuse is equipped with a trip-indicator, the user will be aware that the arrester must be replaced. In order to match a wider market demand, Ferraz-SHAWMUT also offers the fuse alone plus its corresponding accessories, holder and microswitch which allows a remote signalling. The attached list provides a selection of “Isolating fuses” able to withstand once the max peak permissible current Imax. As a matter of principle the selected fuse automatically withstands 20 times the lower peak current I2(and 3 times the I3, former lower peak current in old standards).
PROTECTION CIRCUIT
A
Fuse Supply
Load
ZnO
DEFINITION OF THE STANDARD 8/20MS WAVE
Sometimes the fuse could also be located in A. In this case verify that the load current is compatible with the fuse current rating.
SP8
12/04
Special Purpose Fuses Special Purpose Fuses European Fuses Surge Suppression Fuses
Isolating fuse list Imax (kA) one pulse
Designation
Reference Number
Voltage rating (V)
Current rating (A)
Breaking capacity
1 1 2.5 2.5 3 4.5 4.5 5 5 6.5 6.5 8-10 8-10 8-10 15 15 15 20 20 25 25 35-40 35-40 50-60 50-60 65 65 65 75-100 75-100 75-100 75-100 75-100 120 120 120 120 120
250V FC 6,3A - 5x20 250V FC 6,3A - 5x20 AL 250V FC 10A - 5x20 250V FC 10A - 5x20 AL 250V SA 20A - 6x32 Fus. cil. ind. GI 10x38 S/I 20A 6,921 Cp gRC 14x51 - 50A Fus. cil. ind. GI 10x38 S/I 25A 621 Cp URC 14x51-63A Fus. cil. ind. GI 10x38 S/I 32A 6,921 Cp gRC 22x58-80 Fus. cil. ind. GI 14x51 S/I 32A Fus. Cp 14x51 GGP 32A 6,921 Cp gRC 22x58-100 Fus. cil. ind. GI 14x51 S/I 40A Fus. Cp 14x51 GGP 40A 621 Cp URD 22x58-135 Fus. cil. ind. GI 22x58 S/I 63A Fus. Cp 22x58 GGP 63A Fus. cil. ind. GI 22x58 S/I 80A Fus. Cp 22x58 GGP 80A Fus. cil. ind. GI 22x58 S/I 100A Fus. Cp 22x58 GGP 100A Fus. cil. ind. GI 22x58 S/I 125A Fus. Cp 22x58 GGP 125 gG 00 L 160 gG 1/160 P Fus. GI NH1 C/P 160A gG 0 L/200 gG 1/200P Fus. GI NH1 C/P 200A 6,9 URD 32 TTF 0900 6,9 URD 32 D11A 0900 gG 1 L/250 gG 1/250 P Fus. GI NH2 C/P 250A 6,9 URD 32 TTF 1000 6,9 URD 32 D11A 1000
E 205 785 Z 205 044 T 205 683 B 205 046 J 084 418 D211028 N 220 950 E 213099 V 220 910 A 214107 X 220 820 W 216656 P 200757 C 220 917 X 218198 P 201815 B 220 709 Y 215646 S 214629 Q 217180 F 216159 E 218 205 T 217183 J 219773 H 218208 D 098 305 G 095 594 Z 222478 H 095 020 H 095 595 R 223000 Q 300 072 X 300 193 Z 095 035 K 095 597 T 214147 S 300 074 Y 300 194
250 250 250 250 250 500 690 500 600 400 690 500 500 690 500 500 600 690 500 690 500 500 500 400 400 500 500 690 500 500 690 690 690 500 500 690 690 690
6.3 6.3 10 10 20 20 50 25 63 32 80 32 32 100 40 40 135 63 63 80 80 100 100 125 125 160 160 160 200 200 200 900 900 250 250 250 1,000 1,000
250V-6kA 250V-6kA 250V-6kA 250V-6kA 250V-200kA 500V-120kA 690V-300kA 500V-120kA 600V-100kA 400V-120kA 690V-300kA 500V-120kA 500V-120kA 690V-300kA 500V-120kA 500V-120kA 600V-300kA 690V-80kA 500V-120kA 690V-80kA 500V-120kA 500V-120kA 500V-120kA 400V-100kA 400V-120kA 500V-100kA 500V-100kA 690V-80kA 500V-100kA 500V-100kA 690V-80kA 690V-200kA 690V-200kA 500V-100kA 500V-100kA 690V-80kA 690V-200kA 690V-200kA
12/04
SP9
Catalog Number
MI5FC 25V 6,3 MI5FCP 25V 6,3 MI5FC 25V 10 MI5FCP 25V 10 MI6SA 25V 20 FR10GG 50V 20 FR14GC 69V 50T FR10GG 50V 25 FR14UC 60V 63T FR10GG 40V 32 FR22GC 69V 80T FR14GG 50V 32 FR14GG 50V 32P FR22GC 69V 100T FR14GG 50V 40 FR14GG 50V 40P FR22UD 60V 135T FR22GG 69V 63 FR22GG 50V 63P FR22GG 69V 80 FR22GG 50V 80P FR22GG 50V 100 FR22GG 50V 100P FR22GG 40V 125 FR22GG 40V 125P NH00GG 50V 160-3 NH1GG 50V 160-4 NH1GG 69V 160P-2 NH0GG 50V 200-3 NH1GG 50V 200-4 NH1GG 69V 200P-2 PC32UD 69V 900TF PC32UD 69V 900 D 1A NH1GG 50V 250-3 NH1GG 50V 250-4 NH2GG 69V 250P-2 PC32UD 69V 1000 TF PC32 UD 69V 10CD 1A
Special Purpose Fuses Special Purpose Fuses European Fuses Rotating Fuses C1G Range
Ferraz Shawmut rotating fuses are specially designed for with standing very high mechanical accelerations, up to 6000g. They are perfectly suited to protecting rectifying diodes used in rotating excitors of power producing alternators. Ferraz Shawmut provides every type of mechanical connection required by worldwide manufacturers of rotating excitors.
Features / Benefits • Glass fiber body for reinforced mechanical withstand and stable dimensions. • Internal reinforcement by alumina spacer for withstanding very high accelerations. • Fuse elements are selected to comply with different turbogenerator applications (DSS - WSS - MSS).
Voltage
Ratings
300 V 400 V 500 V 600 V 700 V 750 V 800 V 850 V 1000 V
200 to 550 A 1000 A 400 A 250 A to 950 A 400 A to 950 A 610 A to 800 A 500 A to 1200 A 500 A to 1340 A 15 A to 400 A
Ask us for further details
SP10
12/04
Special Purpose Fuses Special Purpose Fuses European Fuses CV4 Flat Fuses 250V to 7.2kVDC - 3.6kV to 10kVAC
Ferraz Shawmut FLAT FUSE range High technology Ultra Fast fuses for protection of: • Voltage commutated inverters (UPS and drives) (from 250 Vdc to 7200 Vdc) • Medium Voltage drives or softstarters (from 3.6 kVac to 10 kVac)
Flat fuse bodies offer you: • A wide range of rated voltages: these flat body fuse links are available in various body sizes providing protection for high power semiconductors such as diodes, thyristors, GTOs, IGBTs, built into various devices. Thanks to their long flat bodies, nominal voltage can reach 10 kVac (CV4 technology size "2 x 15 x 27"). This is a very good solution for Medium Voltage drive or softstarter protection. Flat fuses have been designed to provide protection solutions for difficult applications (these flat fuses give low I2t responses and have extremely high breaking capacities). • Easy assembly of several bodies connected in parallel to reach a sufficient rating. for example: 325A (one body "2x15x27" 5kV CV4) / 1800A (6 bodies "2x15x27" 5kV CV4 in parallel) 250A (one body "2x15x27" 7.2KV CV4) / 1190A (5 bodies "2x15x27" 7.2KV CV4 in parallel) • Significant improvement of the current carrying capability of the fuse thanks to the possibility of forced air cooling. • Low circuit inductance: (from 10 to 50 nH depending on shape and mounting)
Electrical benefits In nominal conditions, Flat Fuses add a minimum inductance (necessary in a fast switching converter: they can be used in Voltage commutated inverters). In case of a fault, the Flat Fuses are able to ensure total protection of a GTO or rupturing case protection of an IGBT (Flat Fuses avoid IGBT case explosion and keep the busbar safe). Also, they are able to ensure quick disconnection of a damaged module in an inverter.
Mechanical benefits They are easy to install on a busbar and maintenance is also easy. This is only an outline of the Ferraz Shawmut Flat Fuse's possibilities. Technical Support helps you make the best choice both technically and economically speaking. For more information on Flat Fuse range, please contact Ferraz Shawmut Technical Support.
SP12
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Ferraz Shawmut CP Cable Protectors are special purpose limiters which are crimped or bolted to cables to clear and isolate faults quickly, increasing the reliability of service entrance and distribution runs. They are current limiting with a 200,000A interrupting rating, yet will carry low cable overloads which are handled by standard protective devices. Cable Protectors are rated in terms of cable size and material (Al or Cu). Heavier duty CPH Cable Protectors are available on special order. Heat shrinkable (HS) tubing can be specified for field installation. Refer to the Application Information Section for more information.
Reference Numbers Description
Copper
Type
Termination
Cable size*
1
Cable to cable
3
Cable to offset bus
5
Straight bus to offset bus
6
Mole to cable
8
Mole to offset bus
2 1/0 2/0 4/0 250kcmil 350kcmil 500kcmil 750kcmil 2 1/0 2/0 4/0 250kcmil 350kcmil 400kcmil 500kcmil 750kcmil 4/0 250kcmil 350kcmil 500kcmil 750kcmil 4/0 250kcmil 350kcmil 500kcmil 750kcmil 4/0 250kcmil 350kcmil 500kcmil 750kcmil
Catalog Number CP2C1 CP1/0C1 CP2/0C1 CP4/0C1 CP250C1 CP350C1 CP500C1 CP750C1 CP2C3 CP1/0C3 CP2/0C3 CP4/0C3 CP250C3 CP350C3 CP400C3 CP500C3 CP750C3 CP4/0C5 CP250C5 CP350C5 CP500C5 CP750C5 CP4/0C6 CP250C6 CP350C6 CP500C6 CP750C6 CP4/0C8 CP250C8 CP350C8 CP500C8 CP750C8
* kcmil = MCM
Catalog Number CP4/0A1 CP250A1 CP350A1 CP500A1 CP750A1 CP4/0A3 CP250A3 CP350A3 CP500A3 CP750A3 CP4/0C5 CP250C5 CP350C5 CP500C5 CP750C5 CP4/0A6 CP250A6 CP350A6 CP500A6 CP750A6 CP4/0C8 CP250C8 CP350C8 CP500C8 CP750C8
Reference Number N212716 R211684 C218847 D218848 A212198 Y213231 X212195 R219366 S219367 A214245 K216278 Z214750 Z211162 Z214244 T218333 P213729 M212715 E222575 F222576 G215769 F217815 K216784 Y212196 L216279 V219369
Features/Benefits
Catalog Numbering System CP
500 C
Standard Duty CP Heavy Duty CPH Conductor Size Cable Material Copper Aluminum
Aluminium Reference Number E217814 B200883 A201940 Y214243 X213230 W223096 D200885 M216280 Q218330 N201423 Y211161 E215261 X214242 P201424 R218331 T211686 D217307 K216278 Z214750 Z211162 Z214244 T218333 B217305 E215767 S211685 F215262 F218850 F217815 K216784 Y212196 L216279 V219369
C A
Termination Type
Approvals •Ferraz Shawmut Certified
3
•Fiberglass bodies for dimensional stability in harsh environments •Catalog number stamped into terminal for permanent identification •Crimp terminals for aluminum cable include oxide inhibitor •Molded rubber boots or heat shrinkable tubing available for insulation and protection
Ratings •Sizes: #2 to 750kcmil copper 4/0 to 750kcmil aluminium 600VAC, 200kA I.R. SP14
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
TYPE 1 - Cable to cable TYPE 3 - Cable to offset bus TYPE 5 - Bus to offset bus
Type C1 – Dimensions Catalog Number
CP2C1
Reference Number
E217814
CP1/0C1 B200883 CP2/0C1 A201940 CP4/0C1
Y214243
CP250C1 X213230 CP350C1 W223096 CP500C1 D200885 CP750C1 M216280
Type C3 Catalog Number CP2C3 CP1/0C3 CP2/0C3 CP4/0C3 CP250C3 CP350C3 CP400C3 CP500C3 CP750C3
Cable* size
#2 1/0 2/0 4/0 250kcmil 350kcmil 500kcmil 750kcmil
TYPE 6 - Mole to cable
A
7.12 (180) 7.12 (180) 7.12 (180) 7.12 (180) 7.38 (188) 7.62 (194) 9.38 (238) 9.51 (242)
Dimensions-Inches (mm) B D E J
1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
.42 (11) .52 (13) .56 (14) .68 (17) .75 (19) .88 (22) 1.05 (27) 1.32 (34)
1.75 (44) 1.75 (44) 1.75 (44) 1.75 (44) 1.88 (48) 2.00 (51) 2.88 (73) 2.88 (73)
TYPE 8 - Mole to offset bus N
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
.31 (7.9) .39 (9.9) .44 (11) .55 (14) .62 (16) .71 (18) .85 (22) 1.06 (27)
Type C1
Type C3
– Dimensions Reference Number Q218330 N201423 Y211161 E215261 X214242 P201424 R218331 T211686 D217307
Cable* size #2 1/0 2/0 4/0 250kcmil 350kcmil 400kcmil 500kcmil 750kcmil
A 8.87 (225) 8.87 (225) 8.87 (225) 8.87 (225) 9.00 (229) 9.12 (232) 9.12 (232) 10 .00 (254) 10.13 (257)
B 1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 1.44 (37) 1.62 (41) 1.62 (41) 1.88 (48) 2.50 (64)
D 1.12 (28) 1.12 (28) 1.12 (28) 1.12 (28) 1.12 (28) 1.12 (28) 1.12 (28) 1.62 (41) 2.00 (51)
Dimensions-Inches (mm) E J L 1.75 (44) 3.62 (92) .96 (24) 1.75 (44) 3.62 (92) .96 (24) 1.75 (44) 3.62 (92) .96 (24) 1.75 (44) 3.62 (92) .96 (24) 1.88 (48) 3.62 (92) .96 (24) 2.00 (51) 3.62 (92) .96 (24) 2.00 (51) 3.62 (92) .96 (24) 2.88 (73) 3.62 (92) 1.19 (30) 2.88 (73) 3.75 (95) 1.31 (33)
N .31 (7.9) .39 (9.9) .44 (11) .55 (14) .62 (16) .71 (18) .75 (19) .85 (22) 1.06 (27)
1
Type C5 – Dimensions Catalog Number
Reference Number
Cable* size
CP4/0C5
K216278
4/0
CP250C5
Z214750
250kcmil
CP350C5
Z211162
350kcmil
CP500C5
Z214244
500kcmil
CP750C5
T218333
750kcmil
A
10.37 (263) 10.37 (263) 10.37 (263) 10.37 (263) 10.50 (267)
Type C5
Dimensions-Inches (mm) B D J L
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
1.12 (28) 1.12 (28) 1.12 (28) 1.62 (41) 2.00 (51)
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
M
.96 (24) .96 (24) .96 (24) 1.19 (30) 1.31 (33)
1.12 (28) 1.12 (28) 1.12 (28) 1.50 (38) 2.00 (51)
* kcmil = MCM 12/04
SP15
R .42 (11) .52 (13) .56 (14) .68 (17) .75 (19) .88 (22) .88 (22) 1.05 (27) 1.32 (34)
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Type C6
Type C6 – Dimensions Catalog Number
Reference Number
CP4/0C6
B217305
CP250C6
E215767
CP350C6
S211685
CP500C6
F215262
CP750C6
F218850
Type C8 Catalog Number
Cable* size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
Dimensions-Inches (mm) J M
A
B
E
7.87 (200) 8.00 (203) 8.12 (206) 9 .38 (238) 9.51 (427)
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
1.75 (44) 1.88 (48) 2.00 (51) 2.88 (73) 2.88 (73)
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
2.50 (64) 2.50 (64) 2.50 (64) 2.88 (73) 2.88 (73)
N
P
.55 (14) .62 (16) .71 (18) .85 (22) 1.06 (27)
.52 (13) .58 (14) .68 (17) .81 (21) 1.00 (25)
R
.68 (17) .75 (19) .88 (22) 1.05 (27) 1.32 (34)
Type C8
– Dimensions Reference Number
size
CP4/0C8
F217815
4/0
CP250C8
K216784
250kcmil
CP350C8
Y212196
350kcmil
CP500C8
L216279
500kcmil
CP750C8
V219369
750kcmil
A
B
D
9.62 (244) 9.62 (244) 9.62 (244) 10.00 (254) 10.13 (257)
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
1.12 (28) 1.12 (28) 1.12 (28) 1.62 (41) 2.00 (51)
Cable* Dimensions-Inches (mm) J L M
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
.96 (24) .96 (24) .96 (24) 1.19 (30) 1.31 (33)
2.50 (64) 2.50 (64) 2.50 (64) 2.88 (73) 2.88 (73)
N
.52 (13) .58 (14) .68 (17) .81 (21) 1.00 (25)
* kcmil = MCM
SP16
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Type A1 – Dimensions Type A1 Catalog Number
Reference Number
Cable* size
CP4/0A1
N212716
4/0
CP250A1
R211684
250kcmil
CP350A1
C218847
350kcmil
CP500A1
D218848
500kcmil
CP750A1
A212198
750kcmil
Dimensions-Inches (mm) B J N Q
A
13.88 (353) 13.88 (353) 13.88 (353) 15.38 (391) 15.50 (394)
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
3.62 .55 (92) (14) 3.62 .59 (92) (15) 3.62 .71 (92) (18) 3.62 .85 (92) (22) 3.75 1.06 (95) (27)
R
2.50 .85 (64) (22) 2.50 .94 (64) (24) 2.50 1.13 (64) (29) 2.88 1.33 (73) (34) 2.88 1.62 (73) (41)
Thick Wall Copper Tube Hex/Circular Crimp Aluminium Sleeve
Typical Terminal Assembly Details
Type A3 – Dimensions Catalog Number
Reference Number
Type A3 Cable* size
CP4/0A3
Y213231
4/0
CP250A3
X212195
250kcmil
CP350A3
R219366
350kcmil
CP500A3
S219367
500kcmil
CP750A3
A214245
750kcmil
A
B
D
12.25 (311) 12.25 (311) 12.25 (311) 13.00 (330) 13.12 (333)
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
1.12 (28) 1.12 (28) 1.12 (28) 1.62 (41) 2.00 (51)
Dimensions-Inches (mm) J L
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
.96 (24) .96 (24) .96 (24) 1.19 (30) 1.31 (33)
Type A6 – Dimensions
Q
2.50 (64) 2.50 (64) 2.50 (64) 2.88 (73) 2.88 (73)
R
.85 (22) .94 (24) 1.13 (29) 1.33 (34) 1.62 (41)
Type A6
Catalog Number
Reference Number
Cable* size
CP4/0A6
P213729
4/0
CP250A6
M212715
250kcmil
CP350A6
E222575
350kcmil
CP500A6
F222576
500kcmil
CP750A6
G215769
750kcmil
A
B
E
11.25 (286) 11.25 (286) 11.25 (286) 12.38 (314) 12.50 (318)
1.44 (37) 1.44 (37) 1.62 (41) 1.88 (48) 2.50 (64)
2.50 (64) 2.50 (64) 2.50 (64) 2.88 (73) 2.88 (73)
* kcmil = MCM Note: Inside surface of sleeve ends is coated with oxide inhibitor and capped. 12/04
N
.55 (14) .59 (15) .71 (18) .85 (22) 1.06 (27)
SP17
Dimensions-Inches (mm) J N
3.62 (92) 3.62 (92) 3.62 (92) 3.62 (92) 3.75 (95)
.55 (14) .59 (15) .71 (18) .85 (22) 1.06 (27)
P
Q
.52 (13) .58 (14) .68 (17) .81 (21) 1.00 (25)
2.50 (64) 2.50 (64) 2.50 (64) 2.88 (73) 2.88 (73)
R
.85 (22) .94 (24) 1.13 (29) 1.33 (34) 1.59 (41)
Type 5 – Use Copper Cable Protectors Type C5 Type 8 – Use Copper Cable Protectors Type C8
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Copper Cable Protectors with Heat Shrinkable Tubing*
Type C1
Type C3
Type C1, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A Inches mm
7.12 7.38 7.62 9.38 9.51
(180) (188) (194) (238) (242)
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
CP4/0C1-HS CP250C1-HS CP350C1-HS CP500C1-HS CP750C1-HS
Type C3, Copper Cable – Dimensions Cable size
A Inches mm
4/0 8.87 (225) 250kcmil 9.00 (229) 350kcmil 9.12 (232) 500kcmil 10.00 (254) 750kcmil 10.13 (257)
A214751 N213728 C200884 C201942 N216787
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
CP4/0C3-HS CP250C3-HS CP350C3-HS CP500C3-HS CP750C3-HS
Type C5
Type C6
Type C5, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A Inches mm
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
10.37 10.37 10.37 10.37 10.50
CP4/0C5-HS CP250C5-HS CP350C5-HS CP500C5-HS CP750C5-HS
(263) (263) (263) (263) (267)
Z230367 L230355 B201941 P212717 H217817
Type C6, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A230368 D215260 R230360 B214752 Q230382
A Inches mm
7.87 8.00 8.12 9.38 9.51
(200) (203) (206) (238) (242)
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
CP4/0C6-HS CP250C6-HS CP350C6-HS CP500C6-HS CP750C6-HS
B230369 M230356 S230361 L230378 R230383
Type C8
Type C8, Copper Cable – Dimensions Cable size
A Inches mm
4/0 9.62 (244) 250kcmil 9.62 (244) 350kcmil 9.62 (244) 500kcmil 10.00 (254) 750kcmil 10.13 (257)
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
CP4/0C8-HS CP250C8-HS CP350C8-HS CP500C8-HS CP750C8-HS
C230370 A217304 V230363 M216786 S230384
* Transparent heat shrinkable tubing is supplied separately with -HS Catalog No. Maximum curing conditions: 5 seconds at 450˚F.
SP18
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Aluminum Cable Protectors with Heat Shrinkable Tubing*
Type A1
Type A1, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A Inches mm
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
13.88 13.88 13.88 15.38 15.50
CP4/0A1-HS CP250A1-HS CP350A1-HS CP500A1-HS CP750A1-HS
(353) (353) (353) (391) (394)
W230364 G230351 N230357 F230373 Q212718
Type A3
Type A3, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A Inches mm
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
12.25 12.25 12.25 13.00 13.12
CP4/0A3-HS CP250A3-HS CP350A3-HS CP500A3-HS CP750A3-HS
(311) (311) (311) (330) (333)
X230365 H230352 N219892 G230374 N230380
Type A6
Type A6, Copper Cable – Dimensions Cable size
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A Inches mm
Cable protector with heat shrinkable tubing Cat. Number Ref. Number
11.25 11.25 11.25 12.38 12.50
CP4/0A6-HS CP250A6-HS CP350A6-HS CP500A6-HS CP750A6-HS
(286) (286) (286) (314) (318)
Type 5 – Use Copper Cable Protectors Type C5 Type 8 – Use Copper Cable Protectors Type C8
Y230366 J230353 P230358 H230375 P230381
* Transparent heat shrinkable tubing is supplied separately with -HS Catalog Numbers. Maximum curing conditions: 5 seconds at 450˚F.
Molded Rubber Insulating Sleeves** For Type C1 Copper Cable Protectors – Dimensions Catalog Number
Reference Number
Cable* size
4/0CCR
D213236
4/0
500CCR
E214755
A
10.44 (265) 500kcmil 14.19 (360)
B
Dimensions-Inches (mm) C D E F
3.69 3.38 .83 1.33 1.50 (94) (86) (21) (33) (38) 3.69 5.25 1.31 1.81 1.94 (94) (133) (33) (46) (49)
G
2.00 (51) 2.44 (62)
For Type C3 Copper Cable Protectors – Dimensions Catalog Number
Reference Number
Cable* size
4/0CBR
D212201
4/0
500CBR
V213734
A
7.06 (179) 500kcmil 8.94 (227)
B
Dimensions-Inches (mm) C D E F
3.69 3.38 .83 1.33 1.50 (94) (86) (21) (33) (38) 3.69 5.25 1.31 1.81 1.94 (94) (133) (33) (46) (49)
G
2.00 (51) 2.44 (62)
** Molded rubber insulating sleeves are ordered by their own catalog numbers, and not as suffixes to the cable protector catalog numbers. Neoprene coated except as noted. 12/04
SP19
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
CURRENT IN AMPERES
MELTING TIME - CURRENT DATA, 600V FUSES
Copper & Aluminum Cable Protectors - #2-750kcmil
TIME IN SECONDS
MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES
Peak Let-Thru Current Data Copper & Aluminum Cable Protectors - #2-750kcmil - 600V
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES
SP20
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Cable Protectors CP & CPH
Recommended Tooling For Installing CP Cable Protectors on Copper & Aluminum Cables Circular Crimp – Copper Cable Cable** Size
Burndy Hypress & Die Set Y34A Y35 Y39 Y46*
Y48B
4/0 250kcmil 350kcmil 500kcmil 750kcmil
A28R A29R A31R A34R -
C28R C29R C31R C34R C39R
U28RT U29RT U31RT U34RT -
U28RT U29RT U31RT U34RT U39RT
U28RT U29RT U31RT U34RT U39RT
Circular Crimp – Aluminum Cable 4/0 250kcmil 350kcmil 500kcmil 750kcmil
-
U28ART U29ART U31ART U34ART -
U28ART U29ART U31ART U34ART U39ART
U28ART U29ART U31ART U34ART U39ART
C28AR C29AR C31AR C34AR C39AR
Hex/Circular Crimp – Copper Cable Cable** Size
TBMB Tool Die Cat. Number
4/0 250kcmil 350kcmil 500kcmil 750kcmil
T & B Installing Tools 13642 Head Die Cat. Number Code Number
13463 13463 13466 13468 -
11740 11771 11743 11746 11749
TBM 15 Head Die Cat. Number Code Number
54 62 71H 87H 106H
15511 15510 15514 15506 15515
54H 62 71H 87H 106H
66H 71H 87H 106H -
15534 15514 15506 15515 15603
66 71H 87H 106H 125H
Hex/Circular Crimp – Aluminum Cable 4/0 250kcmil 350kcmil 500kcmil 750kcmil
13465 13466 13468 -
11742 11743 11746 11749 -
Hex/Circular Crimp – Copper Cable Note: Crimping tools suitable for standard splicing sleeves are also suitable for CP cable protectors for copper and aluminum cables because Ferraz Shawmut uses standard commercial dimensions on both inside and outside diameters.
Homac Tools UT 15 Head Die
Cable** Size Cat. Number
Code. Number
15511 15510 15514 15587 15500
54H 62 71H 87H 106H
4/0 250kcmil 350kcmil 500kcmil 750 kcmil
Hex/Circular Crimp – Aluminum Cable 4/0 250kcmil 350kcmil 500kcmil 750 kcmil
15534 15514 15506 15515 15603
66 71H 87H 106H 125H
* with adapter P-U-ADP ** kcmil = MCM 12/04
SP21
Special Purpose Fuses Special Purpose Fuses American Fuses Welder Protectors A4BX
WELDER PROTECTORS Ferraz Shawmut Welder Protectors are special purpose limiters used to provide isolation of faulted welding equipment and protection for the cable drop supplying the welder. Welder Protectors have a high thermal capacity and are less affected by high ambient temperatures and extended weld times than similar size Class J or K fuses*. Welder Protectors should only be applied for isolation of short circuited welding circuits. Overload protection must be provided for by other means. * Contact us for Class L sizes and rating
Standard Fuse Ampere Ratings, Reference Numbers Ampere Rating
Catalog Number Class K Class J Dimension Dimension
Reference Number Class K Class J Dimension Dimension
100 125 150 200 225
A4BX100-150 A4BX125-150 A4BX150-150 A4BX200-150 A4BX225-150
A4BX200-150J -
J218876 D212224 S212743 H217334 G211192
M217844 -
300 400 500 600
A4BX300-150 A4BX400-150 A4BX500-150 A4BX600-150
A4BX300-150J A4BX400-150J -
J215288 N217845 M222605 F201968
K215795 Y218360 -
Ratings
Approvals
• 600VAC, 200kA I.R.
• Ferraz Shawmut Certified
CLASS K
CLASS J
A4BX ( ) - 150; Class K Dimensions Ampere Rating
A
B
C
D
Inches E
F
G
H
100 125-200 225-400 500-600
7-7/8 9-5/8 11-5/8 13-3/8
1 1-1/2 2 2-1/2
1/8 3/16 1/4 1/4
23/32 1-1/8 1-5/8 2
2-5/8 3-7/16 4-7/16 5-5/16
-
-
-
1-1/2 2-3/16
4-3/8 5-1/4
3/8 17/32
9/32 13/32
A4BX ( ) - 150J; Class J Dimensions 125-200 225-400
5-3/4 7-1/8
1-1/2 2
3/16 1/4
1-1/8 1-5/8
SP22
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Welder Protectors A4BX
CURRENT IN AMPERES
MELTING TIME - CURRENT DATA, 600V FUSES
A4BX100 to 600 Types 150, 150J
TIME IN SECONDS
MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES
Peak Let-Thru Current Data – A4BX100 to 600, 600 Volts AC
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES
12/04
SP23
Special Purpose Fuses Special Purpose Fuses American Fuses Form 600 A2Y, A6Y
FORM 600 FUSES Ferraz Shawmut Form 600 fuses were the original current-limiting fuses, pre-dating all the standards. Their 500V DC rating (through 600A) is a useful feature for special applications. Form 600 fuses provide a high degree of current limitation in AC and DC applications. Types 1 and 3 are dimensionally interchangeable with Class H and K fuses. Types 4 and 5 have unique rejection dimensions and are not interchangeable.
Ratings
Approvals
• AC: A2Y 1-600A 250VAC, 200kA I.R. A6Y 10-8A 500VAC, 200kA I.R. A6Y 10-1200A 600VAC, 200kA I.R. • DC: A2Y 1-600A 500VDC, 100kA I.R. A6Y 1-8A 500VDC, 100kA I.R. A6Y 10-600A 500VDC, 100kA I.R.
• AC: Guide No. JFHR2 (1-600A) • DC Tested to UL198L Parameters (1-600A) • UL Recognized Component File E60314
Ref. Number
Cat. Number
Ref. Number
Cat. Number
Ref. Number
Ampere Rating
Cat. Number
Ampere Rating
Ref. Number
Ampere Rating
Cat. Number
Ampere Rating
Ampere Rating
A2Y –Standard Fuse Ampere Ratings, Reference Numbers Cat. Number
Ref. Number
1 2 3 5 6
A2Y1-1 A2Y2-1 A2Y3-1 A2Y5-1 A2Y6-1
W222613 P201976 P212234 R215295 Y216313
30 35 40 45 50
A2Y30-1 A2Y35-1 A2Y40-1 A2Y45-1 A2Y50-1
N213268 E213766 N214280 N214786 T215803
80 90 90 100 100
A2Y80-4 A2Y90-3 A2Y90-4 A2Y100-3 A2Y100-4
F218367 H219404 C219928 S218884 F219402
175 200 200 250 250
A2Y175-4 A2Y200-3 A2Y200-4 A2Y250-3 A2Y250-4
B212751 L213266 D213765 Q215294 S215802
400 450 450 500 500
A2Y400-4 A2Y450-3 A2Y450-4 A2Y500-3 A2Y500-4
B219927 V222612 J223131 R200920 E201461
8 10 15 20 25
A2Y8-1 A2Y10-1 A2Y15-1 A2Y20-1 A2Y25-1
G218368 K223132 F201462 Q211200 G211721
60 70 70 70 80
A2Y60-1 A2Y70-3 A2Y70-4 A2Y70-5 A2Y80-3
B216822 C212752 M213267 M214279 X217853
125 125 150 150 175
A2Y125-3 A2Y125-4 A2Y150-3 A2Y150-4 A2Y175-3
Q200919 D201460 M201974 N211198 M212232
300 300 350 350 400
A2Y300-3 A2Y300-4 A2Y350-3 A2Y350-4 A2Y400-3
A216821 R217342 W217852 T218885 G219403
500 600 600 600
A2Y500-5 A2Y600-3 A2Y600-4 A2Y600-5
N201975 P211199 F211720 N212233
Cat. Number
Ref. Number
Cat. Number
Ref. Number
Ampere Rating
Ref. Number
Ampere Rating
Cat. Number
Ampere Rating
Ampere Rating
A6Y –Standard Fuse Ampere Ratings, Reference Numbers Cat. Number
Ref. Number
1 2 3 5 6 8
A6Y1-1 A6Y2-1 A6Y3-1 A6Y5-1 A6Y6-1 A6Y8-1
H216828 Z200927 W214793 R219412 A200928 Q211729
70 80 80 90 90 100
A6Y70-4 A6Y80-3 A6Y80-4 A6Y90-3 A6Y90-3 A6Y100-4
J212758 L213772 V214286 A215809 A215809 Z222616
200 200 225 225 225 250
A6Y200-4 A6Y200-5 A6Y225-3 A6Y225-4 A6Y225-5 A6Y250-3
N223135 W200924 V211204 T212238 G212756 S213272
450 450 500 500 500 600
A6Y450-4 A6Y450-5 A6Y500-3 A6Y500-4 A6Y500-5 A6Y600-3
X215300 Z215808 X217347 M218373 B218892 Q223137
10 15 20 25 30
A6Y10-1 A6Y15-1 A6Y20-1 A6Y25-1 A6Y30-1
N218374 K219935 Y211207 W213275 F216320
100 125 125 125 150
A6Y100-3 A6Y125-4 A6Y125-3 A6Y125-5 A6Y150-3
F219931 F212755 S212237 R213271 R214283
250 250 300 300 300
A6Y250-4 A6Y250-5 A6Y300-3 A6Y300-4 A6Y300-5
S214284 S214790 Y215807 F216826 W217346
600 600 650 650 800
A6Y600-4 A6Y600-5 A6Y650-4 A6Y650-4 A6Y800-4
L201467 W201982 X211206 X211206 V214792
35 40 45 50 60 70
A6Y35-1 A6Y40-1 A6Y45-1 A6Y50-1 A6Y60-1 A6Y70-3
F217861 P218375 D218894 S223139 Z211208 W212240
150 150 175 175 175 200
A6Y150-4 A6Y150-5 A6Y175-3 A6Y175-4 A6Y175-5 A6Y200-3
R214789 V215298 B217857 K218371 Z218890 A222617
350 350 400 400 400 450
A6Y350-3 A6Y350-4 A6Y400-3 A6Y400-4 A6Y400-5 A6Y450-3
A218891 H219933 W211205 V212239 H212757 T214791
800 1000 1000 1200 1200
A6Y800-5 A6Y1000-4 A6Y1000-5 A6Y1200-4 A6Y1200-5
Y215301 M223134 V200923 T211203 K211724
SP24
A
B
Type 1, 1-60 Amperes Class K Dimensions Ampere Rating
Inches A
B
A2Y - 1-60A 1-30 2 9/16 35-60 3 13/16 A6Y - 1-60A 1-30 35-60
5 13/16 5-1/2 1-1/16 12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Form 600 A2Y, A6Y
Type 3, 70-600 Amperes, Class K Ampere Rating
- Dimensions
Inches A
B
C
D
E
J
250 VAC/500 VDC - A2Y (Amp) - 3 70-100 125-200 225-400 450-600
5-7/8 7-1/8 8-5/8 10-3/8
1 1-1/2 2 2-1/2
1/8 3/16 1/4 1/4
23/32 1-5/8 2-21/32 1-1/8 2-3/16 2-25/32 1-5/8 2-15/16 2-25/32 2 3-13/16 2-25/32
600 VAC/500 VDC - A6Y (Amp) - 3 70-100 110-200 225-400 450-600
7-7/8 9-5/8 11-5/8 13-3/8
1 1-1/2 2 2-1/2
1/8 3/16 1/4 1/4
23/32 1-1/8 1-5/8 2
2-5/8 3-7/16 4-7/16 5-5/16
Type 3
2-21/32 2-25/32 2-25/32 2-25/32
70-600A
Type 4, 70-600 Amperes – Dimensions Ampere Rating
A
B
C
D
Inches E
F
H
J
P
4-7/8 5-3/4 6-3/4 8-1/8
13/64 17/64 21/64 25/64
2-21/32 1/2 2-25/32 11/16 2-25/32 15/16 2-25/32 1-1/8
6-7/8 8-1/4 9-3/4 11-1/8
13/64 17/64 21/64 25/64
2-21/32 1/2 2-25/32 11/16 2-25/32 15/16 2-25/32 1-1/8
250 VAC/500 VDC - A2Y (Amp) - 4 70-100 125-200 225-400 450-600
5-7/8 7-1/8 8-5/8 10-3/8
1 1-1/2 2 2-1/2
1/8 3/16 1/4 1/4
23/32 1-5/8 1-1/8 2-3/16 1-5/8 2-15/16 2 3-13/16
600 VAC/500 VDC - A6Y (Amp) - 4 70-100 125-200 225-400 450-600
7-7/8 9-5/8 11-5/8 13-3/8
1 1-1/2 2 2-1/2
1/8 3/16 1/4 1/4
23/32 1-1/8 1-5/8 2
2-5/8 3-7/16 4-7/16 5-5/16
Type 4
70-600A
1/4
Type 4, 650-1200 Amperes Ampere Rating
A
B
Inches E F
D
- Dimensions
J
K
Q
3-3/4
1-5/16
5/8
600 VAC only - A6Y (Amp) - 4 650-1200
10-1/2
3
2
3-3/8
7-7/8
Type 4
650-1200A
Type 5, 125-600 Amperes/Hinge Disconnect type – Dimensions Ampere Rating
A
B
C
D
Inches E
F
G
3-7/16 4-7/16 5-5/16
8-1/4 9-3/4 11-1/8
3/4 7/8 1
H
J
P
600 VAC/500 VDC - A6Y (Amp) - 5 125-200 225-400 450-600
10-3/4 1-1/2 13-1/4 2 15-3/16 2-1/2
3/16 1/4 1/4
1-1/8 1-5/8 2
17/64 2-25/32 11/16 21/64 2-25/32 15/16 25/64 2-25/32 1
Type 5
125-600A
Type 5, 650-1200 Amperes/Hinge Disconnect Type – Dimensions 1/4
Ampere Rating
A
B
D
Inches E F
1/2
1
J
K
Q
3-3/4
1-5/16
5/8
Dia
600 VAC only - A6Y (Amp) - 5 650-1200
12-1/8
3
2
3-3/8
7-7/8
Type 5
12/04
SP25
650-1200A
Special Purpose Fuses Special Purpose Fuses American Fuses Form 600 A2Y, A6Y
1-600 Amperes, 250 or 600 Volts - Types 1, 3 or 5 800-1200 Amperes, 600 Volts - Types 4 or 5 MELTING TIME - CURRENT DATA
DC Capability Cat No. Prefix
Ampere Rating
DC Voltage Rating*
A2Y A6Y
1-600 1-600
500 500
TIME IN SECONDS
*Consult factory for specifics regarding circuit time constants and DC interrupting rating.
Recommended Fuse Blocks With Box Connectors For Form 600 Types 1 & 3 Fuses Ampere
250V
Rating 1 Pole Catalog Number
600V
3 pole
1 Pole
3 pole 60308
1-30
20306
20308
60306
31-60
20606
20608
60606
60608
61-100
21036
21038
61036
61038
101-200
22001
22003
62001
62003
201-400
24001
24003
64001
64003
401-600
2631
2633
6631
6633
Reference Number CURRENT IN AMPERES
10-600 Amperes, 250 or 600 Volts 800-1200 Amperes, 600 Volts only PEAK LET-THRU CURRENT DATA
1-30
Z212381 F215446 V211871
X213920
31-60
N211865 C214431 X211873
Z213922
61-100
S201105 Q211867 K201627
S211363
101-200
Y213415 E214433 M212393
H213424
201-400
T219046
H218530
T219575
401-600
F214434 K215450 Z216475
-
W217507
MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES
A variety of pole configurations and termination provisions is available. Refer to Fuse Blocks and Fuse Holders section for details.
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES SP26
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Plug Fuses
PLUG FUSES: G/GP/TD/GW /GTL/GT/GSL Ferraz Shawmut Plug Fuses are for industrial and residential applications. Standard non-time delay fuses are for receptacle and lighting circuits. Standard time delay fuses are for motor loads. For Canadian requirements, a type “P” fuse is used for non-motor loads and type “D” fuses are used for electric heating and cycling loads circuits. Both fuses have low melting-point temperature elements. Low-Temp time delay plug fuses have thermal sensitivity are also for cycling loads and motor circuits. Type “S” plug fuses are time delay and tamper-resistant.
Ratings
Approvals
• 125V AC, 10kA I.R. • 3 to 30 Amperes • Choice of Edison Base, Types “P”, “D”, or “S”
• UL Listed Guide JEFV, File E76208 • CSA Certified Class 142301, File 15525
Plug Fuses – Standard Fuse Ampere Ratings, Reference Numbers Ampere Rating
Edison Base Time “P” Type Non Delay Time-Delay UL CSA
Non-Time Delay UL
Non-Time Delay CSA
GW3 GW6 GW10 GW15 GW20 GW25 GW30
G3 G6 G10 -
GTL15 GTL20 GTL25 GTL30
G214389 K215404 K212345 V212860 D213374 X213874 G214895
V218472 N218995 N217960 -
K219521 N222721 T201060 B203804
low-Temp Time-Delay UL
“D” Type Time-Delay CSA
Type S rejection* Time-Delay UL
GP15 GP20 GP25 GP30
GT15 GT20 GT25 GT30
TD15 TD20 TD25 TD30
GSL15 GSL20 GSL25 GSL30
Y223236 F211306 T212859
K217451 T217965 A218477 S218999
P201056 R211822 T213871 H215908
C213373 F214388 J215403 Q216421
Catalog Number
3 6 10 15 20 25 30 Reference Number
3 6 10 15 20 25 30
* Must be used with an SAG adaptator to fit an Edison base fuse holder
FR15, FR20 Rejector Rings FRW Rejection tool
Type S Plug Fuses adaptators Cat. Number/Rating
ref Number
Fuse range - amps
SAG3-2/10 SAG6-1/4 SAG6-3/10 SAG15 SAG20 SAG30
Z216935 P230427 V217966 M215912 R216422 L217452
1-8/10 - 3-2/10 3-1/2 - 6-1/4 2-1/2 - 6-1/4 7 - 15 20 25 - 30
Type S adaptors screw into the Edison base and allow Type S fuses to be installed. Type S adaptors prevent the wrong ampere size fuse from being used. 12/04
SP27
Special Purpose Fuses Special Purpose Fuses American Fuses In line Fuse SLR - SMF - SHR
Ferraz Shawmut SLR and SMF in-line fuses are used to protect fluorescent lighting fixtures and ballasts. The SLR is a fast-acting fuse. SMF is a time-delay fuse. Both used to protect individual 300V fixtures. Ferraz Shawmut SHR fuse holder has an integral clip for panel mounting to meet this requirement. The holder fits into a standard 7/8” knock-out or keyhole punch that provides anti-rotation. The SHR is available in a single or double wire version. The single wire version (SHR-1) allows insertion of #18 AWG ballast leads directly into the holder.
SLR FUSES Ratings
SMF FUSES Ratings
SHR FUSE HOLDERS Ratings
• 300VAC, 100A I.R. 125VAC, 10kA I.R. 1/2 to 15A
• 300VAC, 100A I.R. 125VAC, 10kA I.R. 3/10 to 10A
• 300VAC: 15A Withstand Rating: 10kA I.R. Dielectric Strength: 2,000 V
Approvals
Approvals
Approvals
• UL Listed File No. E10480 CSA Certified
• UL Listed File No. E10480 CSA Certified
• UL Recognized Component Guide IZLT2, UL File No. E52283
Highlights:
Highlights:
Highlights:
• Fast Acting • Integral fuse & insulating cap
• Time-Delay • Integral fuse & insulating cap • Designed specifically to handle ballast inrush currents
• Superior wire retention • Thermoplastic Insulator - 150º C RTI • Single and two wire versions • Two load plug-in ports available • Integral mounting clip - 0.062” thick panel • Integral wire retention clip to hold #18 wire • Tin plated, insulated #18 solid copper wire leads, 6” length
SP28
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses In line Fuse SLR - SMF - SHR
Ampere Ratings, Reference Numbers Ampere Rating
Catalog Number
300mA 500mA 600mA 800mA 1A 1-1/4A 1-1/2A 1-6/10A 2A 2-1/2A 2-8/10A 3A 3-2/10A 4A 5A 6A 61/4A 7A 8A 9A 10A 12A 15A
Reference Number
SMF3/10 SMF1/2 SMF6/10 SMF8/10 SMF1 SMF1-1/4
SLR1/2
SLR1 SLR1-1/2 SLR1-6/10 SLR2 SLR2-1/2
M215521
Q211936 C212453 T213986 Q217571 X218083
SMF1-6/10 SMF2 SMF2-1/2 SMF2-8/10 SMF3 SMF3-2/10 SMF4 SMF5
SLR3 SLR4 SLR5 SLR6
P211429 D212454 M212968 W213482 V213987 D214501
A218592 T219115 P219640 A222088
SMF61/4 SMF7 SMF8
SLR7 SLR8 SLR9 SLR10 SLR12 SLR15
R211937 E215008 R216537 Y201685 P205702
N222836 A223353 T201175 V216034 Q216536 F217056
SMF10
Fuse Holders
.26 7.0 mm
Single wire
Two wire
SHR-1
SHR
.25 6.35 mm
Note: Both holders are compatible with all fluorescent light fuses
.5
load wire load(Black) wire
.5 .5 Stripped
12.8 mm
.13 .13
(Black)
.19
wire length Stripped wire length
.5 .5 Stripped
wire length Stripped wire length
48 mm
load wire load(red) wire 6(red)
6
5.1 5.1
2.32 2.32
.28 .28
.670 Grips onto .18 AWG wire
.202 Note: SHR1, line wire only
Ø.875 12/04
SP29
Special Purpose Fuses Special Purpose Fuses American Fuses Surge Suppresion Fuses VSP
Ferraz Shawmut surge suppression fuses are specially designed to address the protection of TVSS systems. Surge suppression fuses have been specially designed to withstand 8x20 mSec surge pulses without opening, allowing the TVSS system to react to the surge. All surge suppression fuses have a 8x20 mSec surge rating, not a continuous current rating. Under AC short circuit conditions these surge suppression fuses are very current limiting.
Features/Benefits • • • •
VSP fuses rated 600 VAC, 200kA I.R. Surge Ratings of 5-100kA 8x20 µ sec capacity Designed to help meet UL1449 Second Edition Requirements Various Mounting Configurations: ferrules, blade, bolt-in, pc board mount
Ratings
Approvals
Aplications:
• 5-100 kA 8x20 µSec Weveform 600 VAC, 200 kA I.R.
• UL Recognized Component • File E60314, Vol.3 Special Purpose MOV Protector
• Protection of TVSS Devices • Coordination with other protection devices
Catalog Number
Reference Number
Voltage Rating (AC)
VSP5-2,R,-H,-S VSP10-2,R,-H,-S VSP15-2,R,-H,-SVSP20-2,R,-H,-S VSP30-2 VSP40-2 VSP50-2 VSP60-2 VSP70-2 VSP80-2 VSP90-2 VSP100-2 VSP100-XL
G219886 X217807 L227572 W218841 X230457 J211677 W232250 F212709 G213722 S214744 X232251 F201416 L230447
600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 600V 480V 600V
8x20 µsec Surge Rating 5,000 10,000 15,000 20,000 30,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 100,000
Melting I2t (A2S)
Clearing I2t (A2S)
Ipeak@ 100KA (60 Hz (A)
341 1,541 3,072 4,992 12,507 19,543 32,020 42,808 61,152 79,872 99,000 121,500 121,500
936 3,744 8,424 14,400 33,696 59,904 93,600 134,784 183,456 239,616 303,264 374,400 374,400
3,652 5,794 7,591 9,194 12,044 14,588 16,925 19,110 21,176 23,146 25,034 26,854 26,854
Recommended Fuse Blocks for VSP Fuses VSP(5-20)-2 Catalog Number Number of poles
Adder 1 2 3
Box
Screw
Pressure plate
30310 30311 30312 30313
30320 30321 30322 30323
30350 30351 30352 30353
VSP(30-100)-2 Catalog Number Number of poles
Adder 1 2 3
VSP(5-20)-2 Reference Number Number of poles Adder 1 2 3
Box
Screw
N211888 A212405 E214456 F214963
S218033 Y218544 K222787 B201642
Box
Screw
Pressure plate
60305J 60306J 60307J 60308J
60315J 60316J 60317J 60318J
60325J 60326J 60327J 60328J
VSP(30-100)-2 Reference Number
Pressure plate F214457 G214964 L216486 Z217004
Number of poles
Adder 1 2 3
SP30
Box
Screw
K204893 N218029 J211884 P219065 S213433 Y222040 A214452 V223302
Pressure plate
Y212403 T213434 B214453 F215469
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Surge Suppresion Fuses VSP
Dimensions VSP (30-100)-2
VSP (5-20)-2,R,H,S
-2 1-1/2” (38.1 mm)
13/32” (10.3mm)
.81” (20.6 mm)
2.25” (57.2 mm)
VSP30-100
PC BOARD MOUNTING 2XR .128 FULL RADIUS
.50 (12.8) .08 (1.8)
1.53 (30.9)
-R
.28 (7.2) 10.5 MAX. REF
.04 (1.0)
MOUNTING HOLE DETAIL
.334 .816
.12 (3.0)
.02 (.4)
.04 (1.0)
.256 .12 (3.0)
.080
FOR .062(1.6) NOMINAL CIRCUIT BOARD THICKNESS
.483
2.250 3.040 3.592
.500
VSP100-XL DOUBLE HOLE MOUNT (ROUND HOLES)
.38 (9.7)
.50 (12.6)
-H .03 (1.3) 4 PLCS
1.53±.01 (30.9)
.03 (.8) .20 (5.1)
MOUNTING HOLE DETAIL
.28 .75 (7.1) (19.0)
.05 (1.4) .15 (3.8) .05 (1.2) .41 (10.5)
2.62 (66.5) 3.62 (91.9) 4.62 (117.3)
.20 (5.1)
MAX REF FOR .062 (1.6) NOMINAL CIRCUIT BOARD THICKNESS
.12 (3.0) .50 (12.7)
1.12 (28.4)
SURFACE (SCREW) MOUNT .17 (4.2)
2.36 (59.9) 1.96 (49.9)
.20 (5.0) .35 (10.0)
-S 1.50 (38.1)
.17 (4.2)
.4 (10.5)
.46 (11.7) .03 (.8)
MAXIMUM RECOMMENDED SCREW SIZE #6 (3.5mm)
MAXIMUM INSTANTANEOUS PEAK LET-THRU AMPERES
Peak Let-Thru Current data
AVAILABLE CURRENT IN RMS SYMMETRICAL AMPERES
12/04
SP31
Special Purpose Fuses Special Purpose Fuses American Fuses Surge Suppresion Fuses TPMOV
Thermally protected mov The Ferraz Shawmut Thermally Protected MOV has been developed to assist in eliminating the failure characteristics of Metal-Oxide-Varistors. The TPMOV is a fail-safe device. It is composed of a voltage clamping device and a disconnecting apparatus that monitors the status of the metaloxide disk. In the event that the disk is approaching breakdown it is effectively disconnected from system power. The TPMOV is rated for 40ka of 8/20us surge current. The TPMOV ratings are available from 150V to 550V. The TPMOV has been designed with two built in isolated indicating features. The first is a visual indicator. When the unit has disconnected from system power, two isolated pins will be noticed atop the TPMOV enclosure. The second feature is a remote indicator composed of a N/O microswitch. In the event that the TPMOV has disconnected system power the switch will change status. These features lower costly engineering time that would be required for traditional MOV products.
Ratings • 150V to 550VAC/100KA I.R. • 40ka 8/20µs Withstand
Approvals • UL 1449 2nd Edition Recognized
Layout
Features/Benefits • • • •
The TPMOV footings are similar* to that of equivalent voltage ratings of traditional 25 to 40mm MOV's. The TPMOV can be utilized on existing systems that utilize traditional MOV’s without costly board redesigns.
High Energy Capacity Consistent footprint with 25–40mm MOV’s Built-In Visual/Remote Indication Fail-Safe Operation
*refer to dimensional drawings on next page.
Application: • • • • • • • •
Transient Voltage Surge Suppressors AC/DC Distribution Systems High Voltage Power Supplies Telecommunications Equipment Motor Control Systems Computer Related Products PLC Applications Power Transfer Switches
Typical Application
Source
SP32
Load
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Surge Suppresion Fuses TPMOV
Dimensions
12/04
Reference Number
catalog Number
safety standards Recognition
X230595 Z230597 A230598 B230599 C230600 D230601
150TPMOV 250TPMOV 270TPMOV 320TPMOV 420TPMOV 510TPMOV 550TPMOV
UL1449 UL1449 UL1449 UL1449 UL1449 UL1449 UL1449
maximum rating AC DC
150V 250V 270V 320V 420V 510V 550V
SP33
200V 330V 360V 420V 550V 675V 700V
peak current 1 pulse 8/20us
40,000A 40,000A 40,000A 40,000A 40,000A 40,000A 40,000A
TPMOV voltage @ 1mA Vmin Vmax
212V 354V 382V 453V 594V 722V 778V
259V 432V 466V 553V 725V 881V 950V
Special Purpose Fuses Special Purpose Fuses American Fuses Forklift Fuses ACK, ACL, ALS
FORKLIFT TRUCK FUSES Ferraz Shawmut forklift truck and battery isolator fuses are specially designed for the heavy duty loads associated with DC battery powered equipment such as forklift trucks, hand trucks, motorized work platforms, and other DC battery operated systems. Rugged construction and stud mounted bolt-in design assure long life in adverse conditions for these fuses.This expanded line of Forklift Truck Fuses can fulfill virtually all of your heavy duty circuit protection needs up to 125V AC or DC. The round body ACK, ACL and ALS fuses combine higher voltage ratings and more ampere ratings with higher breaking capacity. The flat CNL and CNN style fuses have a lower voltage rating but are also AC and DC, more space saving and have visual “see-thru” indication to show when they have operated.
Features/Benefits
Approvals
• • • •
• UL Recognized Components (All Products) File E60314
All fuses are AC and DC rated Expanded Ampere Ratings Time Delay and General Purpose types Link is visible through window (CNL/CNN)
Ratings
Highlights:
Applications:
• • • • •
• Forklift Trucks • Battery Hand Trucks • Motorized Work Platforms • Battery Systems
AC/DC Ratings Embossed Catalog Nos. Stud Mounted Time Delay - ACK General Purpose - ACL,ALS
Forklift Truck Fuse - Cross Reference Part Number
Competitor name
Gould
ACK ACL ALS ANL ANN AOK CCK CCL ECK ECL ENLE ENNE
Bussmann Bussmann Bussmann Bussmann Bussmann Edison Littelfuse Litttelfuse Edison Edison Edison Edison
ACK ACL ALS CNL CNN ALS ACK ACL ACK ACL CNL CNN
• ACK: 1-400 Amperes 125VAC, 10kA I.R. 125VDC, 10kA I.R. • ACL: 30-120 Amperes 125VAC, 10kA I.R. 125VDC, 10kA I.R. • ALS: 100-500 Amperes 125VAC, 10kA I.R. 125VDC, 10kA I.R. • CNL* • CNN* *see section “European DIN forklift fuses
Forklift Truck Fuse - Fuse Blocks
SP34
Fuse
Fuse Block
ACK(70-100) ACL(70-120)
P243C P243E
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Forklift Fuses ACK, ACL, ALS
ACK1 ACK2 ACK3 ACK5 ACK6 ACK10 ACK15
B219421 G212250 J215311 Y218383 C219422 V219944 Y201478
Ref. Number
20A 25A 30A 35A 40A 50A 60A
ACK20 ACK25 ACK30 ACK35 ACK40 ACK50 ACK60
T212767 G214297 M215820 V216839 J217358 N218903 W219945
70A 80A 90A 100A 120A 140A 150A
ACK70 ACK80 ACK90 ACK100 ACK120 ACK140 ACK150
Ref. Number
P222630 Z201479 J201994 N222629 C223148 J200936 H201993
160A 175A 200A 225A 250A 300A 400A
Ref. Number
W216840 K217359 S217872 Z218384 P218904 D219423
Cat. Number
Ref. Number
ACK160 ACK175 ACK200 ACK225 ACK250 ACK300 ACK400
H211216 Y211736 G213285 Y213783 G214803 R216330 R217871
Cat. Number
Ref. Number
300A 350A 400A 450A 500A –
ALS300 ALS350 ALS400 ALS450 ALS500 –
Ref. Number
30A 35A 40A 50A 60A
ACL30 ACL35 ACL40 ACL50 ACL60
H212251 V212768 H213286 Z213784 H214298
Cat. Number
Ref. Number
70A 80A 90A 100A 120A
ACL70 ACL80 ACL90 ACL100 ACL120
H214804 N215821 S216331 J211217 Z211737
Ampere Rating
Cat. Number
Ampere Rating
ALS Fuse
Ampere Rating
ACL Fuse
Cat. Number
Ampere Rating
1A 2A 3A 5A 6A 10A 15A
Cat. Number
Ampere Rating
Ref. Number
Ampere Rating
Cat. Number
Ampere Rating
Ampere Rating
ACK Fuse
Cat. Number
100A 150A 175A 200A 225A 250A
ALS100 ALS150 ALS175 ALS200 ALS225 ALS250
X219946 Q222631 E223150 K200937 A201480 –
Dimensions Catalog Number
ACK 1-30 ACK 35-60 ACK 70-100 ACK 120-200 ACK 225-400 ACL 30-60 ACL 70-120 ALS 100-500
12/04
Outline Figure
1 1 1 1 1 1 1 1
A
B
C
D
E
F
G
In. (mm) 3.07 (77.9) 3.74 (95) 4.46 (113.4) 4.72 (119.8) 4.71 (119.7) 3.07 (77.9) 3.49 (88.6) 4.71 (119.7)
In. (mm) 2.5 (63.5) 3 (76.2) 3.5 (88.9) 3.75 (95.4) 3.75 (95.4) 2.5 (63.5) 2.75 (69.9) 3.75 (95.4)
In. (mm) .56 (14.3) .81 (20.6) 1.06 (26.9) 1.06 (26.9) 1.06 (26.9) .56 (14.3) .81 (20.6) 1.06 (26.9)
In. (mm) .5 (12.7) .75 (19.1) 1 (25.4) 1 (25.4) 1 (25.4) .5 (12.7) .75 (19.1) 1 (25.4)
In. (mm) .28 (7.1) .34 (8.7) .38 (9.5) .38 (9.5) .38 (9.5) .28 (7.1) .34 (8.7) .38 (9.5)
In. (mm) .593 (15) .86 (21.8) 1.12 (28.5) 1.12 (28.5) 1.12 (28.5) .593 (15) .86 (21.8) 1.12 (28.5)
In. (mm) .03 (.8) .047 (1.2) .06 (1.6) .06 (1.6) .06 (1.6) .03 (.8) .047 (1.2) .06 (1.6)
SP35
Special Purpose Fuses Special Purpose Fuses American Fuses Forklift Fuses ACK, ACL, ALS
MELTING TIME – CURRENT DATA – ACK70–400
CURRENT IN AMPERES
CURRENT IN AMPERES
MELTING TIME – CURRENT DATA – ACL30–120
MELTING TIME – CURRENT DATA – ALS100–500
TIME IN SECONDS
TIME IN SECONDS
TIME IN SECONDS
TIME IN SECONDS
MELTING TIME – CURRENT DATA – ACK1–60
CURRENT IN AMPERES
CURRENT IN AMPERES SP36
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses 70 series
70 SERIES • Color Coded tip • Rated 125V AC, 300V DC • UL Recognized 125 VAC, 1000A I.R.; 300V DC, 1000A I.R. Guide JDYX2, File E39265 • Continuous rated current is 80% of 10 minute rating (shown in table). 100% rating 10 minutes minimum
70 series alarm indicating telecommunications fuses Ferraz Shawmut 70 Series Alarm Indicating fuses are used in telecommunications equipment. Each ampere rating has aspecific color-coded tip for easy visual identification.
Reference Numbers, Ampere Ratings, Certifications 10 minute Ampere Rating
Catalog Number
Reference Number
Color Code
100mA 150mA 180mA 200mA 250mA 250mA 350mA 500mA 750mA 1.33A 2A 3A 3.5A 5A 8A 10A
70P 70R 70E 70X 70F 70K 70S 70G 70H 70A 70B 70C 70J 70D 70M 70N
G201555 R203404 Z217947 D211810 E218458 T222703 T211295 X218980 P219502 R215893 W216403 D216916 L221960 R217434 J223223 A201043
Gray-White Red-White Yellow Black Violet Violet-White Gray Red Brown White Orange Blue Black-White Green-Black Tan-White Yellow-Purple
SP38
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses GMS
GMS/GMSC/GMSD • • • • • •
Safety Covers Color Coded Lubricated Ryton Body Material Rated 125V AC, 125V DC UL Recognized 125 V AC, 300A I.R.; 125V DC, 300A I.R. Guide JDYX2, File E39265 • Carry 100% load - 10 minutes, min. clear 150% load - 5 minutes, max.
GMS series alarm indicating telecommunications fuses Ferraz Shawmut GMS Series Alarm Indicating fuses are used in telecommunications equipment or other applications. A color coded flag indicates a circuit problem which caused the fuse to blow. Nineteen ampere ratings/colors fill every replacement need. GMS: Alarm indicating telecommunications fuse GMSC: Safety cover for GMS fuse (not shown) GMSD: Dummy fuse to protect unused circuits
GMSD
Reference Numbers, Ampere Ratings, Certifications
12/04
Ampere Rating
Catalog Number
Reference Number
Volts
Color Code
180mA 200mA 250mA 500mA 650mA 750mA
GMS 18/100 GMS2/10 GMS1/4 GMS1/2 GMS65/100 GMS3/4
Z215509 S217044 S212444 E211926 F211927 N218581
125 125 125 125 125 125
Yellow Black-Red Violet Red Black Brown
1A 1.33A 1.5A 2A 2.5A 3A
GMS1 GMS1-1/3 GMS1-1/2 GMS2 GMS2-1/2 GMS3
L201674 C211418 V205477 G216022 C216524 C217559
125 125 125 125 125 125
Gray White White-Yellow Orange White-Orange Blue
3.5A 4A 5A 7.5A 10A 12A 15A
GMS3-1/2 GMS4 GMS5 GMS7-1/2 GMS10 GMS12 GMS15
J218071 B219628 R222080 T212445 C212959 G213975 S214491
125 125 125 125 125 125 125
White-Blue White-Brown Green Black-White Red-White Yellow-Green Red-Blue
SP39
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses TGL - TGN - TGS
Ferraz Shawmut telecommunications fuses are specially designed for the protection of telecommunications equipment which includes telephone switching equipment, rectifiers, distribution switching panels, battery back-up modules, power supplies and switching sub-stations. The telecom fuses are available from 1 to 800 amperes rated at 170VDC with an interrupting rating of 100,000 amps to fulfill your circuit protection needs. The telecom fuses have high current limiting capabilities to provide a better degree of circuit protection to traditional telecommunications equipment. These fuses consist of a blue and white label for easy identification of their DC voltage capability.
Features/Benefits • • • •
All fuses rated 170VDC, 100kA I.R. Extremely current limiting Blue & white labels for easy identification Various mounting configurations
Highlights
Applications
Ratings
Approvals
• DC Rated • Highly Current Limiting • Fast Acting • Rejection Style
• • • • •
• TGL: 70-800 A 170VDC, 100kA I.R. • TGN: 1-600 A 170VDC, 100kA I.R. • TGS: 1-70 A 170VDC, 100kA I.R.
• UL Recognized Components File #E60314
Distribution Switching Panels Battery Back-up Systems Power Supplies Switching Substations Telephone Switching Rectifiers
Telecom fuse Cross Reference Competitor Part Number
Ferraz Part Number
TPL TPN TPS
TGL TGN TGS
Recommended Fuse Holder Reference Number
Recommended Fuse Holder Catalog Number Fuse
TGL TGN
TGS
Ampere
1 Pole
70-250 300-800 0-30 31-60 61-100 101-200 201-400 401-600 0-70A
P243D P243G 20306R 20606R 21036R 22001R 24001R 2631R 30656T
3 Pole
Fuse
TGL 20308R 20608R 21038R 22003R 24003R 2633R 30658T
TGN
TGS
SP40
Ampere
1 Pole
3 Pole
70-250 300-800 0-30 31-60 61-100 101-200 201-400 401-600 0-70A
C219560 H222762 T213411 B213383 D201621 R213915 J219566 H214942 X219049
K215956 E214939 M212899 G214941 D222022 P215960 G222 025
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses TGL - TGN - TGS
TGN Catalog Numbers, Standard Ampere Rating Catalog Number
Reference Number
Ampere rating
Catalog Number
Reference Number
Ampere rating
Catalog Number
Reference Number
Ampere rating
TGN1 TGN3 TGN5 TGN6 TGN10 TGN15 TGN20 TGN25 TGN30 TGN35
F216849 X211229 Z215831 X217370 W217369 B218915 B222641 M201491 M211749 G212779
1A 3A 5A 6A 10A 15A 20A 25A 30A 35A
TGN40 TGN45 TGN50 TGN60 TGN70 TGN80 TGN90 TGN100 TGN110 TGN150
M213796 S214813 D216341 F217884 C218916 R219435 K219958 E217883 L218395 Q219434
40A 45A 50A 60A 70A 80A 90A 100A 110A 150A
TGN175 TGN200 TGN225 TGN250 TGN300 TGN350 TGN400 TGN450 TGN500 TGN600
J219957 P223159 W200947 Q202161 W212263 V213297 V214309 W215322 G216850 M218396
175A 200A 225A 250A 300A 350A 400A 450A 500A 600A
Melting Time - Current Data
Dimensions
TIME IN SECONDS
A 0-60A
170 VDC TGN Fuses Ampere Rating
A In.
0-30 2 31-60 3 61-100 5-7/8 101-200 7-1/8 201-400 8-5/8 401-60010-3/8
CURRENT IN AMPERES
12/04
B
SP41
B mm
In.
51 9/16 76 13/16 149 1-1/16 181 1-9/16 219 2-1/16 264 2-9/16
C mm
In.
14 21 27 1/8 40 3/16 53 1/4 66 1/4
D mm
In.
3 5 6 6
3/4 3/4 1-5/8 2
E mm
In.
mm
19 1 25 19 1-3/8 35 41 1-7/8 48 51 2-1/4 57
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses TGL - TGN - TGS
TGL Catalog Numbers, Standard Ampere Rating Catalog Number
Reference Number
Ampere rating
Catalog Number
Reference Number
Ampere rating
TGL-BA TGL-BB TGL-BC TGL-BD TGL-BE TGL-BF TGL-BG TGL-BH TGL-BK
A218914 P219433 H219956 A222640 N223158 V200946 L201490 T202118 W211228
70A 80A 90A 100A 125A 150A 175A 200A 225A
TGL-BL TGL-CN TGL-CO TGL-CR TGL-CU TGL-CV TGL-CZ TGL-CZH
L211748 V212262 T213296 L213795 T214308 R214812 V215321 Y215830
250A 300A 350A 400A 450A 500A 600A 800A
Dimensions .31 (7.9)
.13 (3.2)
.25 (6.4)
.41 (10.4) 1.00 (25,4)
1.00 (25.4)
1.25 (31.0)
1.16 (29.4)
2.13 (54.1)
1.88 (47.5)
ø 1.50 (38.1)
2.75 (69.9)
2.19 (55.6) 2.66 (67.5)
Fig. 1 BA(70A) – BL(250A)
3.50 (88.9)
Fig. 2 CN(300A) – CZH(800A)
TIME IN SECONDS
Melting Time - Current Data
CURRENT IN AMPERES SP42
12/04
Special Purpose Fuses Special Purpose Fuses American Fuses Telecom Fuses TGL - TGN - TGS
TGS Catalog Numbers, Standard Ampere Rating Catalog Number
Reference Number
Ampere rating
Catalog Number
Reference Number
Ampere rating
TGS1 TGS2 TGS3 TGS5 TGS6 TGS10 TGS15
C222642 N201492 N211750 W213298 W214310 Q223160 X200948
1A 2A 3A 5A 6A 10A 15A
TGS20 TGS25 TGS30 TGS40 TGS50 TGS60 TGS70
D202173 Y211230 X212264 H212780 N213797 T214814 X215323
20A 25A 30A 40A 50A 60A 70A
Dimensions
.88 ± .02 [22.35± .5mm]
ø .566± .006 [14.3± .015mm]
Melting Time - Current Data
TIME IN SECONDS
MAXIMUM INSTANTANEOUS PEAK LET - THRU AMPERES
Peak Let - Thru Current Data
AVAILABLE DC CURRENT IN AMPERES (10 MS TIME CONSTANT )
CURRENT IN AMPERES
12/04
SP43