CONCRETE FOR COLUMNS by VOLUME METHO LEVEL Ground Floor

COLUMNS

WIDTH(m)

1C-1

LENGTH(m) 0.3

0.3

CONCRETE FOR BEAMS AND GIRDERS by VOLUME M LEVEL Ground Floor Roof

BEAMS and GIRDERS TB-1 RB-1

WIDTH(m)

HEIGHT(m) 0.2 0.2

0.4 0.4

CONCRETE FOR SLABS by VOLUME METHOD LEVEL Ground Floor

AREA OF SLAB and BEAMS

AREA OF BEAMS

AREA OF SLAB

R COLUMNS by VOLUME METHOD (CLASS "A" MIXTURE) HEIGHT(m)

UNIT 2.7

43

VOLUME(m^3) CEMENT(40kg/Bag) 10.449 94.041

SAND(cu.m.) 5.2245

MS AND GIRDERS by VOLUME METHOD (CLASS "A" MIXTURE) TOTAL LENGTH(m) 231.15 231.15

VOLUME(m^3) CEMENT(40kg/Bag) 18.492 166.428 18.492 166.428

SAND(cu.m.) 9.246 9.246

GRAVEL(cu.m.) 18.492 18.492

SAND(cu.m.)

GRAVEL(cu.m.)

OR SLABS by VOLUME METHOD (CLASS "A" MIXTURE) THICKNESS OF SLAB

VOLUME(m^3)

CEMENT(40kg/Bag) 0 0

0

0

GRAVEL(cu.m.) 10.449

QUANTITY OF CHB BY AREA METHOD (4`` by 8`` by 16`` CHB) LEVEL Ground Floor

Area of doors, AREA of (Hw) HEIGHT OF (Lw) TOTAL NET windows and WALL,doors,window WALL(m) LENGTH OF WALL(m) columns (m^2) s,andcolumns (m^2) 2.7 243.57 657.639 96.4

QUANTITY OF CEMENT MORTAR BY AREA METHOD (4`` by 8`` by 16`` CHB)(Cla LEVEL Ground Floor

AREA OF CEMENT(40kg/Bag) WALL(m^2) 561.239 445

SAND(cu.m.) 24.4138965

QUANTITY OF CEMENT MORTAR FOR PLASTERING BY AREA METHOD (4`` by 8`` by mixture)(25mm plaster) LEVEL Ground Floor

AREA OF 2 SIDES CEMENT(40kg/Bag) OF WALL(m^2) 1122.478 506

SAND(cu.m.) 28.06195

CONCRETE HOLLOW BLOCK FOOTING BY VOLUME METHOD (4`` by 8`` by 16`` CHB) LEVEL Ground Floor

(Lw) TOTAL NET LENGTH OF WALL(m) 243.57

VOLUME(m^3) 24.357

CEMENT(40kg/Bag) 220

SAND(cu.m.) 12.1785

(4`` by 8`` by 16`` CHB) AREA OF WALL(m^2) 561.239

no. of CHB per sq. m.

Quantity of CHB(pieces)

12.5

7016

`` by 8`` by 16`` CHB)(Class ``A`` mixture)

A METHOD (4`` by 8`` by 16`` CHB)(Class ``A`` ster)

D (4`` by 8`` by 16`` CHB)(Class ``A`` mixture) GRAVEL(cu.m.) 24.357

FORMS FOR COLUMN (1/4'' by 4' by 8' Plywood and 2" b LEVEL

Ground Floor

LEVEL Ground Floor Roof

COLUMN

WIDTH (m)

1C-1

LENGTH (m)

0.3

0.3

HEIGHT (m)

2.7

FORMS FOR BEAMS AND GIRDERS (1/4'' by 4' by 8' Plywood an

BEAMS and GIRDERS TB-1 RB-1

WIDTH(m)

HEIGHT(m)

0.2 0.2

PERIMETER(m) 0.4 0.9 0.4 0.9

' by 4' by 8' Plywood and 2" by 2'' lumber) PERIMETER (m)

No. of Columns

1.2

43

Area (m^2)

Quantity of Plywood (pieces)

139.32

S (1/4'' by 4' by 8' Plywood and 2" by Quantity 2'' lumber) of TOTAL LENGTH (m)

AREA (m^2)

0 0

Plywood (pieces) 0 0

49

Quantity of Wood Frame(board 0 foot) 0

Quantity of Wood Frame(board foot) 1454

NOTE: Phenolic

NOTE: Phenolic Board ang mas magandang gamitin para maulit Ilang ulit gagamitin ang Phenolic board? Bale ang mga nacompute na forms ay madidivide pa, sa anong number ididivide?

QUANTITY of MATERIALS for ROOFING ANGLE BARS L-2"x2"X1/4" TRUSS TYPE 1 2 3 4 5 6 7 BRACING

L-1"x1"x1/4"

LENGTH (m) 303.76 36.8 38.94

LENGTH (m) 321.04 27.44 30.54

37.6

47.12

TURNBUCKLE

12mm Diameter LENGTH (m)

QUANTITY (pcs.)

C-PURLINS 100mm by 50mm by 1.6mm LENGTH (m)

SAGRODS 10mm diameter LENGTH (m)

OOFING

MATERIALS DUPLEX CONVENIENCE OUTLET AIRCON OUTLET AIR HANDLING UNIT EXHAUST FAN FLUORESCENT INCANDESCENT PANELBOARD CIRCUIT BREAKER PINLIGHTS TWO GANG SWITCH SINGLE GANG SWITCH WIRE

QUANTITY (pcs) 68 9 2 4 45 9 1 34 19

QUANTITY OF GYMPSUM BOARD INSIDE THE BUILDING (1/4" by 4" by 8") LEVEL

GROUND FLOOR

AREA OF THE CEILING (m^2)

AREA OF 1 BOARD QUANTITY OF GYMPSUM (m^2) BOARD (pieces) 2.88 0

4" by 4" by 8")

QUANTITY OF TILES AND CEMENT MORTAR by FUNDAMENTAL MET

CEMENT MORTAR

TILES

LEVEL

GROUND FLOOR G.F. COMFORT ROOMS SECOND FLOOR S.F. COMFORT ROOMS

FLOOR AREA (m^2)

WIDTH (m)

LENGTH (m)

QUANTITY OF TILES (PIECES)

0.6

AREA OF TILES (m^2) 0.6 0.36

0.6

0 0.36

#DIV/0! 0

0

#DIV/0!

0.6

0

FUNDAMENTAL METHOD CEMENT MORTAR CEMENT(40kg/B ag)

WHITE CEMENT JOINT FILLER (kg) 4 0.18

TILE ADHESIVE (40kg/Bag) 0.0396

0 4

0 0.18

0 0.0396

0

0

0

AREA of Concrete to be painted

Primer (Acrytex Primer 1705)

Putty(Spot) (Boysen Acrytex Cast #1701)

Topcoat (Boysen Wallguard)

mm^2 760

Liters 122

Liters 122

Liters 203

AREA of Ceiling to be painted m^2

DV 1360

DV 1000

Interior Primer & Sealer

Prolux Glazing Putty (full putty)

Liters

Liters

DV 400 Quick Gloss-It Drying Enamel(White) - 2 Coats

Liters

Thinning Solvent for Putty (Boysen Acrytex Reducer #1750)

Liters 16

Thinning Solvent for Primer (Boysen Acrytex Reducer #1750)

Liters 31

Related Documents

Sdec Estimate.xlsx
October 2019 14

More Documents from "Scott Cobb"

Sdec Estimate.xlsx
October 2019 14
Boys Dorm Estimate.xlsx
October 2019 18
Function Hall Estimate.xlsx
October 2019 15
Sadac Estimate.xlsx
October 2019 10
Girls Dorm Estimate.xlsx
October 2019 11