Accessibility Survey Americans with Disabilities Act And Title 24 of the California Building Code

San Joaquin County Fairgrounds Prepared By Disability Access Consultants, Inc. (800) 743-7067

WORKING DRAFT 1658 S. Airport Way Stockton, CA

Facility Name: San Joaquin Fairgrounds Programs, Services, and Activities Finding:

The San Joaquin Fairgrounds, located at 1658 South Airport Way in Stockton California, was inspected by Disability Access Consultants, Inc., on May 8 and 9, 2006.

Alternative Rec: (Where Available)

*

Full Rec

Any renovation or new construction that occurred after January 26, 1992, is subject to meet full code specifications for the California Building Code and ADAAG requirements. All recommendations in this report are based on ADAAG and CBC title 24 requirements. Consult with your design professional to determine which elements are affected by these requirements. It is recommended that Disability Access Consultants, Inc. is consulted for inspection of any new construction or renovation at the facility.

Citation

ADAAG 4.1.2; ADAAG 4.1.3; ADAAG 4.1.5; ADAAG 4.1.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number Priority:

0 103

Parking Finding:

There are seven parking lots provided at the facility. The paved parking lots are located outside of the main entrance gate, outside of the Winners Gaming and Sports Emporium, outside of Buildings 1, 2, 4 and 6 thru 8, outside of Flates BBQ, next to the Horse Barns, next to the soccer field and outside of the Maintenance Shop.

Alternative Rec: (Where Available)

*

Full Rec

Accessible paved parking spaces shall be located on the shortest accessible route of travel to the facility and shall coincide with the primary route and primary entrances used by the general public (see CBC 1129B.4, ADAAG 4.3.2(1) and ADAAG 4.14.1).

Citation

CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.14.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 104

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 1 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

Parking is provided off-street to the public and/or employees outside of Buildings 1, 2, 4 and 6 thru 8, though no marked spaces are provided.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec

Stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6. Accessible parking spaces shall be located on the shortest accessible route of travel to the facility for which it serves and shall coincide with the primary route and entrances used by the general public (see CBC 1129B and ADAAG 4.3.2(1). The access aisle and route to the primary facility entrance shall also be of an accessible surface.

Citation

CBC 1129B; ADAAG 4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

113

Priority:

Parking Finding:

Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec

Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The van-accessible parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 114

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 2 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

150

Maximum Estimated Cost:

150

Record Number

115

Priority:

Parking Finding:

Paved parking is provided outside of Flats BBQ. There are no accessible parking spaces designated out of 17 total parking spaces provided in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Flats BBQ Full Rec

One out of the 17 total number of marked parking spaces is required to be designated exclusively for accessible parking, as required by CBC 1129B and ADAAG. Create one vanaccessible parking space measuring at least 108 inches wide and 216 inches long with an access aisle measuring at least 96 inches wide (8 feet) located on the passenger side (right side) of the parking space (see CBC 1129B). Add the words NO PARKING in 12 inch high white letters at the entrance to the accessible parking access aisle.

Citation

CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.6.2; ADAAG 4.1.2(5)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

270 270 116

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 3 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

The designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Flats BBQ Full Rec

Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from the accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

150

Maximum Estimated Cost:

150

Record Number

117

Priority:

Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of Flats BBQ Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 118

Priority:

Page 4 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

Alternative Rec: (Where Available)

There are 14 accessible parking spaces provided. Each accessible parking space provided measures at least 108 inches wide and 216 inches long. The two van-accessible parking spaces each provide an access aisle, located on the passenger side of the parking space, measuring 96 inches wide. Two of the standard accessible parking spaces provide an adjacent access aisle measuring 95 inches wide. There is no access aisle provided adjacent to ten of the standard accessible parking spaces. The access aisles do not contain "NO PARKING" in 12" high white letters *

Parking Lot Outside of the Main Entrance Gate Full Rec

Fourteen parking spaces meets the number required to be designated exclusively for accessible parking according to ADAAG and CBC 1129B. Restripe the designated accessible parking spaces to create two van-accessible and 12 standard accessible parking space, each measuring at least 108 inches wide and 216 inches long. The van-accessible spaces shall provide an access aisle measuring at least 96 inches wide (8 feet) on the passenger side (right side) of the vehicle space (see CBC 1129B). The additional parking spaces shall each provide an access aisle measuring at least 60 inches wide, that may be shared. Add the words NO PARKING in 12 inch high white letters at the entrance to each accessible parking access aisle.

Citation

CBC 1129B; ADAAG 4.6; ADAAG A4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

270

Maximum Estimated Cost:

270

Record Number

106

Priority:

Parking Finding:

There is no crosswalk provided on the path of travel from the accessible parking spaces to the facility. The required accessible route crosses a vehicular way.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Main Entrance Gate Full Rec

Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.

Citation

ADAAG 4.7.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

100 100 107

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 5 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

There is no vertically-mounted signage at the designated accessible parking spaces in the parking lot showing the International Symbol of Accessibility. There is no additional signage marked "van-accessible" at the van-accessible parking spaces.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Main Entrance Gate Full Rec

Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

150

Maximum Estimated Cost:

150

Record Number

108

Priority:

Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Main Entrance Gate Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 109

Priority:

Page 6 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

Parking is provided off-street to the public and/or employees outside of the Maintenance Shop, though the parking lot surface is gravel and nonaccessible.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Maintenance Shop Full Rec

Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.

Citation

CBC 1129B; ADAAG 4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

125

Priority:

Parking Finding:

There is signage designating one nonaccessible parking space as accessible. The designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Maintenance Shop Full Rec

Remove the signage designating the nonaccessible parking space as accessible. Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from the accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The van-accessible parking space shall provide an additional sign marked "vanaccessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 126

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 7 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Maintenance Shop Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 127

Priority:

Parking Finding:

There are 12 accessible parking spaces out of 344 parking spaces which is sufficient in number as required for compliance.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec

Twelve out of the 344 total number of marked parking spaces meets the number required to be designated exclusively for accessible parking according to ADAAG and CBC 1129B.

Citation

CBC 1129B; ADAAG 4.6; ADAAG A4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 110

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 8 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

Alternative Rec: (Where Available)

Parking Continued: Two of the accessible parking spaces measure less than 108 inches wide and at least 216 inches long. Ten of the accessible parking spaces measure at least 108 inches wide and 216 inches long. The van-accessible parking space provides an access aisle, located on the passenger side of the vehicle space, measuring at least 96 inches wide. Each standard accessible parking space provides an adjacent access aisle measuring 60 inches wide. The access aisles do not contain "NO PARKING" in 12" high white letters *

Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec

Restripe the designated accessible parking spaces to create one van-accessible and one standard accessible parking space, each measuring at least 108 inches wide and 216 inches long with an access aisle measuring at least 96 inches wide (8 feet) shared between the two accessible parking spaces (see CBC 1129B). The accessible parking space with the access aisle to the right of the space shall be designated "van-accessible." Add the words NO PARKING in 12 inch high white letters at the entrance to each accessible parking access aisle.

Citation

CBC 1129B; ADAAG 4.6; ADAAG A4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

270 270 111

Priority:

Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 112

Priority:

Page 9 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

Parking is provided off-street to the public next to the Horse Barns, though the parking lot surface is gravel and nonaccessible. The parking lot can provide approximately 40 parking spaces.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Horse Barns Full Rec

Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.

Citation

CBC 1129B; ADAAG 4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

119

Priority:

Parking Finding:

Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Horse Barns Full Rec

Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 120

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 10 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Horse Barns Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

150

Maximum Estimated Cost:

150

Record Number

121

Priority:

Parking Finding:

Parking is provided off-street to the public next to the soccer field, though the parking lot surface is gravel and nonaccessible. The parking lot can provide approximately 66 parking spaces.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Soccer Field Full Rec

Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.

Citation

CBC 1129B; ADAAG 4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 122

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 11 of 542

Facility Name: San Joaquin Fairgrounds Parking Finding:

There is signage designating two of the nonaccessible parking spaces as accessible. Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Soccer Field Full Rec

Remove the signage designating the nonaccessible parking spaces. Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "vanaccessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).

Citation

CBC 1129B.5; ADAAG 4.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

150

Maximum Estimated Cost:

150

Record Number

123

Priority:

Parking Finding:

There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.

Alternative Rec: (Where Available)

*

RV Parking Lot Next to the Soccer Field Full Rec

Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

150 150 124

Priority:

Page 12 of 542

Facility Name: San Joaquin Fairgrounds Passenger Loading Zones Finding:

There is no required striped access aisle adjacent to the passenger loading zone. There is no signage designating accessibility posted at the passenger loading zone.

Alternative Rec: (Where Available)

*

Passenger Loading Zone Outside of the Winners Emporium Full Rec

Stripe an access aisle at least 5 feet (60 inches) wide and 20 feet (240 inches) long adjacent and parallel to the vehicle pull-up space. The access aisle striping for the passenger loading zone shall provide immediate access to the adjacent curb ramp. Post signage designating the passenger loading zone as accessible (see CBC 1131B and ADAAG 4.1.2(7)(b)). The sign should contain the International Symbol of Accessibility.

Citation

CBC 1131B; ADAAG 4.6.6; ADAAG 4.1.2(7)(b)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

300 300 128

Priority:

Curb Ramps Finding:

The slope of the top landing is greater than 2%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.

Alternative Rec: (Where Available)

*

Curb Ramp at the Winners Gaming and Sports Emporium Main Entrance Full Rec

Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).

Citation

CBC 1127B.5.3; ADAAG 4.7.2 & 4.29

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1033

Maximum Estimated Cost:

1033

Record Number

131

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 13 of 542

Facility Name: San Joaquin Fairgrounds Curb Ramps Finding:

The built-up curb ramp projects into vehicular traffic and interferes with individuals entering or exiting parked or standing vehicles. The slope of the curb ramp is greater than 8.33%. The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.

Alternative Rec: (Where Available)

*

Curb Ramp Outside of Flats BBQ Full Rec

Remove the asphalt built-up curb ramp and install a compliant curb-cut ramp that provides a slope no greater than 8.33% and complies with CBC 1127B; ADAAG 4.7. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).

Citation

CBC 1127B; ADAAG 4.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1400

Maximum Estimated Cost:

1400

Record Number

129

Priority:

Curb Ramps Finding:

The slope of each side of the concrete sidewalk curb ramp is greater than 8.33%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.

Alternative Rec: (Where Available)

*

Curb Ramp Outside of the Winners Gaming and Sports Emporium Full Rec

Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).

Citation

CBC 1127B.5.3; ADAAG 4.7.2 & 4.29

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1033

Maximum Estimated Cost:

1033

Record Number

134

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 14 of 542

Facility Name: San Joaquin Fairgrounds Curb Ramps Finding:

The slope of the curb ramp is greater than 8.33%. The slope of the side flares is greater than 10%. The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.

Alternative Rec: (Where Available)

*

Curb Ramp to the Women's Showers Full Rec

Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).

Citation

CBC 1127B.5.3; ADAAG 4.7.2 & 4.29

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1033

Maximum Estimated Cost:

1033

Record Number

133

Priority:

Curb Ramps Finding:

The built-up curb ramps provided at the accessible parking spaces outside of the Winners Gaming and Sports Emporium project into an access aisle and interfere with individuals entering or exiting parked or standing vehicles. The slope of the side flares is greater than 10%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.

Alternative Rec: (Where Available)

*

Curb Ramps at the Accessible Parking Spaces Full Rec

Remove each built-up curb ramp and install a compliant curbcut ramp that provides a slope no greater than 8.33% and complies with CBC 1127B; ADAAG 4.7. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).

Citation

CBC 1127B; ADAAG 4.7

Minimum Quantity

1

Maximum Quantity:

7

Unit:

Each

Minimum Estimated Cost:

1400

Maximum Estimated Cost:

9800

Record Number

132

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 15 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is no accessible route from the public right of way off of B Street to the accessible entrance of the facility. The accessible route crosses vehicular traffic.

Alternative Rec: (Where Available)

Post directional signage.

Accessible Route from the Public Right of Way Full Rec

Provide at least one accessible route from the public right of way to the accessible entrance of the facility. Make certain to post signage indicating the direction to accessible building entrances at every major junction along the accessible route. Signs shall include the International Symbol of Accessibility.

Citation

CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3; ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

107

Maximum Estimated Cost:

0

Record Number

202

Priority:

Path of Travel Finding:

There is no crosswalk provided on the path of travel from the public right of way off of B Street to Flats BBQ. The required accessible route crosses a vehicular way.

Alternative Rec: (Where Available)

*

Accessible Route from the Public Right of Way Full Rec

Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance of the facility. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.

Citation

ADAAG 4.7.9 ADAAG 4.2.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

100 100 203

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 16 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is no accessible route from the public right of way off of South 8th Street to the accessible entrance of the facility. The accessible route crosses vehicular traffic.

Alternative Rec: (Where Available)

Post directional signage.

Accessible Route from the Public Right of Way Full Rec

Provide at least one accessible route from the public right of way to the accessible entrance of the facility. Make certain to post signage indicating the direction to accessible building entrances at every major junction along the accessible route. Signs shall include the International Symbol of Accessibility.

Citation

CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3; ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

107

Maximum Estimated Cost:

0

Record Number

221

Priority:

Path of Travel Finding:

There is no crosswalk provided on the path of travel from the public right of way off of South 8th Street to the facility. The required accessible route crosses a vehicular way.

Alternative Rec: (Where Available)

*

Accessible Route from the Public Right of Way Full Rec

Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance of the facility. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.

Citation

ADAAG 4.7.9 ADAAG 4.2.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

100 100 222

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 17 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are only stairs to the primary functions provided on the stage in Building 2, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Building 2 Full Rec

Install a vertical platform lift to provide a direct path between the stage and level seating area in Building 2, allowing individuals with mobility impairments to participate in programs, services and activities provided by the facility on the stage. The ADA mandates accessibility to programs, services and activities which serve the public.

Citation

CBC 1114B.1.2; ADAAG 4.3.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

0 8210 189

Priority:

Path of Travel Finding:

The width of the gate next to the reception counter in Building 7 is less than 32 inches making the area nonaccessible to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

Modify or replace the gate, to provide at least 32 inches in width (see CBC 1133B.1.1.1.4; ADAAG 4.13.3). Make certain the gate provides level and clear landings on each side of the gate and that each landing provides the minimum maneuvering clearances required. The gate shall provide accessible hardware.

Citation

CBC 1133B.1.1.1.4; CBC 1133B.1.1.1.1; ADAAG 4.13.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 137

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 18 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The mat does not adhere to the underlying floor surface and creates a hazardous path of travel.

Alternative Rec: (Where Available)

*

Building 7 Main Entrance Full Rec

Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.

Citation

CBC 1124B.3; ADAAG 4.5.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

659

Maximum Estimated Cost:

659

Record Number

136

Priority:

Path of Travel Finding:

There is grating outside of Building 6 with elongated openings greater than 1/2 inch running the along the direction of travel.

Alternative Rec: (Where Available)

*

Drainage Grate Full Rec

Replace the grating with a grating that provides openings equal to or less than 1/2 inch wide. If the grating has elongated openings, the grating shall be set where the elongated openings are perpendicular to the dominant direction of travel (see CBC 1133B.7.2 and ADAAG 4.5.4).

Citation

CBC 1133B.7.2; ADAAG 4.5.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

588 588 148

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 19 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

Lockers are a service provided for public use in the exercise room at the Stable Office. The lockers have hardware which requires tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Lockers Full Rec

When an individual with a disability has need for the locker service, modify a locker as needed or provide equivalent facilitation upon request.

Citation

CBC 1105.4.3; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

159

Priority:

Path of Travel Finding:

The mat at the south entrance to the Main Building does not adhere to the underlying floor surface and creates a hazardous path of travel.

Alternative Rec: (Where Available)

*

Main Building (South Entrance) Full Rec

Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.

Citation

CBC 1124B.3; ADAAG 4.5.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

659 659 166

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 20 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are open tree wells along the path of travel in Building 6 with a change in elevation greater than 1/2 inch, creating a tripping hazard.

Alternative Rec: (Where Available) Open Tree Wells Full Rec

Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).

Citation

ADAAG 4.3.8; CBC 1133B.7.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

70

Maximum Estimated Cost:

70

Record Number

149

Priority:

Path of Travel Finding:

There are open tree wells along the path of travel next to L-4 and L-5 with a change in elevation greater than 1/2 inch, creating a tripping hazard.

Alternative Rec: (Where Available) Open Tree Wells Full Rec

Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).

Citation

ADAAG 4.3.8; CBC 1133B.7.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

70 70 152

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 21 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are open tree wells along the path of travel south of L-5 with a change in elevation greater than 1/2 inch, creating a tripping hazard.

Alternative Rec: (Where Available) Open Tree Wells Full Rec

Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).

Citation

ADAAG 4.3.8; CBC 1133B.7.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

70

Maximum Estimated Cost:

70

Record Number

213

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel between Buildings 5 and 6.

Alternative Rec: (Where Available)

*

Path of Travel Between Buildings 5 and 6 Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

175

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 22 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is a change in elevation greater than 1/2 inch on the primary path of travel between L-4 and L-5.

Alternative Rec: (Where Available)

*

Path of Travel Between L-4 and L-5 Full Rec

Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).

Citation

CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

212

Priority:

Path of Travel Finding:

The walkway serves as a primary path of travel. The width of the bridge is less than 48 inches in width. There are slopes greater than 8.33% on the primary path of travel on the walkway.

Alternative Rec: (Where Available)

*

Path of Travel in Building 6 Full Rec

Modify the exterior primary path of travel by extending the width of the walkway to at least 48 inches (see CBC 1118B.2 and ADAAG 4.3.3). Since the accessible route is less than 60 inches in width, provide passing spaces at least 60 inches by 60 inches at reasonable intervals every 200 feet. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1; CBC 1133B.2.3; CBC 1118B.2; ADAAG 4.1.3(16); ADAAG 4.3.3; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 197

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 23 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The width of the interior path of travel behind the counter in L-1 is less than 36 inches.

Alternative Rec: (Where Available)

*

Path of Travel in L-1 Full Rec

Modify the interior path of travel to provide at least 36 inches in width. If the interior path of travel includes 180-degree turn around an object, the clear width shall be at least 42 inches (see CBC 1118B.1, CBC 1118B.3 and ADAAG 4.3.3).

Citation

CBC 1118B.1; CBC 1118B.3; ADAAG 4.3.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 141

Priority:

Path of Travel Finding:

The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.

Alternative Rec: (Where Available)

*

Path of Travel in L-1 Full Rec

Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).

Citation

CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

200

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 24 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public. There are cross slopes greater than 2% on the primary path of travel.

Alternative Rec: (Where Available)

*

Path of Travel in L-4 Full Rec

Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5). Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

211

Priority:

Path of Travel Finding:

There is a change in elevation greater than 1/2 inch on the primary path of travel.

Alternative Rec: (Where Available)

*

Path of Travel in the FFA Office Full Rec

Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).

Citation

CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

172

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 25 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel at the west end of the Linden Lions Building.

Alternative Rec: (Where Available)

*

Path of Travel in the West End of the Linden Lions Building Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

153

Priority:

Path of Travel Finding:

The typical paths of travel throughout Building 6 is gravel, preventing access to individuals with mobility impairments. The width of typical walkways is less than 48 inches in width.

Alternative Rec: (Where Available)

*

Path of Travel Throughout Building 6 Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

198

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 26 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.

Alternative Rec: (Where Available)

*

Path of Travel Throughout L-2 Full Rec

Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).

Citation

CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

169

Priority:

Path of Travel Finding:

The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.

Alternative Rec: (Where Available)

*

Path of Travel Throughout L-3 Full Rec

Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).

Citation

CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

170

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 27 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The path of travel from the parking lot to Building 4 is gravel, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to Building 4 Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

151

Priority:

Path of Travel Finding:

The surface of the primary accessible path of travel from Building 6 to Building 5 is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.

Alternative Rec: (Where Available)

*

Path of Travel to Building 5 Full Rec

Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).

Citation

CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

196

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 28 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The path of travel to the north entrance of Building 5 is grass, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to Building 5 (North Entrance) Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

215

Priority:

Path of Travel Finding:

The path of travel to the south entrance to Building 6 is grass, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to Building 6 (South Entrance) Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

214

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 29 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is a step on the primary path of travel to Building 8, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to Building 8 Full Rec

Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.

Citation

CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

9515

Maximum Estimated Cost:

9515

Record Number

135

Priority:

Path of Travel Finding:

The path of travel is to L-6 grass, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to L-6 Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

143

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 30 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The path of travel to the annex next to the Jockey's Quarters is dirt, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Annex Next to the Jockey's Quarters Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

259

Priority:

Path of Travel Finding:

There are only stairs to the primary functions provided, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Annex Next to the Jockey's Quarters Full Rec

Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.

Citation

CBC 1133B.5; ADAAG 4.3.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

9515

Maximum Estimated Cost:

9515

Record Number

260

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 31 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the bleachers at the Delta Speedway.

Alternative Rec: (Where Available)

*

Path of Travel to the Bleachers at the Delta Speedway Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

178

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel between the men's and women's restroom at the Grandstand.

Alternative Rec: (Where Available)

*

Path of Travel to the Bleachers at the Grandstand Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

145

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 32 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is a change in elevation greater than 1/2 inch on the primary path of travel.

Alternative Rec: (Where Available)

*

Path of Travel to the Building 5 Main Entrance Full Rec

Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).

Citation

CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

150

Priority:

Path of Travel Finding:

There are slopes greater than 8.33% on the primary path of travel on the walkway to the concession stand at the south east end of the Grandstand.

Alternative Rec: (Where Available)

*

Path of Travel to the Concession Stand Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Otherwise, install a ramp that does not exceed a slope greater than 8.33% and complies with CBC 1133B.5 and ADAAG 4.8.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

144

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 33 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the concession stand at the Delta Speedway.

Alternative Rec: (Where Available)

*

Path of Travel to the Concession Stand at the Delta Speedway Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

177

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel from the restrooms to the concession stand at the Delta Speedway.

Alternative Rec: (Where Available)

*

Path of Travel to the Concession Stand at the Delta Speedway Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

179

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 34 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 8.33% on the primary path of travel on the walkway from Charter Way to the Delta Speedway.

Alternative Rec: (Where Available)

*

Path of Travel to the Delta Speedway Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Otherwise, install a ramp that does not exceed a slope greater than 8.33% and complies with CBC 1133B.5 and ADAAG 4.8.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

201

Priority:

Path of Travel Finding:

There is a step on the primary path of travel to the First Aid Room in the Maintenance Building, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the First Aid Room Full Rec

Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.

Citation

CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

9515

Maximum Estimated Cost:

9515

Record Number

193

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 35 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The path of travel to Horse Barns A thru U, excluding Horse Barn S, is dirt, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Horse Barns Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

176

Priority:

Path of Travel Finding:

The path of travel from the Stable Office to the Horse Barns is a combination of dirt, gravel and asphalt, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Horse Barns Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

204

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 36 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The path of travel to the north entrance of the Jockey's Quarters is dirt, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Jockey's Quarters (North Entrance) Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

205

Priority:

Path of Travel Finding:

The path of travel to the Linden Lions Building is grass, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Linden Lions Building Full Rec

Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.

Citation

CBC 1114B.1.2; ADAAG 4.3.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

154

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 37 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the men's restroom next to Horse Barn N.

Alternative Rec: (Where Available)

*

Path of Travel to the Men's Restroom Next to Horse Barn N Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

130

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the men's restroom next to Horse Barn Q.

Alternative Rec: (Where Available)

*

Path of Travel to the Men's Restroom Next to Horse Barn Q Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

305

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 38 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5%, due to an asphalt build-up, on the primary path of travel to the men's showers next to the Livestock Office.

Alternative Rec: (Where Available)

*

Path of Travel to the Men's Showers Next to the Livestock Office Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

713

Priority:

Path of Travel Finding:

There is a step on the primary path of travel to the milk parlor, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Milk Parlor Full Rec

Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.

Citation

CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

9515

Maximum Estimated Cost:

9515

Record Number

199

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 39 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the press box at the Delta Speedway.

Alternative Rec: (Where Available)

*

Path of Travel to the Pressbox at the Delta Speedway Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

1440 1440 1178

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the second level of the Grandstands.

Alternative Rec: (Where Available)

*

Path of Travel to the Second Level of the Grandstands Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

147

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 40 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are only stairs to the primary functions provided, preventing access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Path of Travel to the Stockton Motorplex Office Full Rec

Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.

Citation

CBC 1133B.5; ADAAG 4.3.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

9515

Maximum Estimated Cost:

9515

Record Number

164

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the women's restroom at the Grandstand.

Alternative Rec: (Where Available)

*

Path of Travel to the Women's Restroom at the Grandstand Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

167

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 41 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There are slopes greater than 5%, due to an asphalt build-up, on the primary path of travel to the women's restroom at the soccer field.

Alternative Rec: (Where Available)

*

Path of Travel to the Women's Restroom at the Soccer Field Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

896

Priority:

Path of Travel Finding:

There are slopes greater than 5% on the primary path of travel to the women's restroom next to horse barn 4.

Alternative Rec: (Where Available)

*

Path of Travel to the Women's Restroom Next to Horse Barn 4 Full Rec

Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.

Citation

CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

467

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 42 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

There is no accessible route to the picnic tables in the outdoor dining area east of Building 6.

Alternative Rec: (Where Available)

*

Picnic Tables East of Building 6 Full Rec

Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.

Citation

ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

194

Priority:

Path of Travel Finding:

The knee space at the tables in the outdoor dining area is less than 27 inches high.

Alternative Rec: (Where Available)

*

Picnic Tables East of Building 6 Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 195

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 43 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The leading edge of the wall-mounted storage compartments in the Jockey's Quarters is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Object Full Rec

Install side extensions, modify, relocate, or lower the storage compartments so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).

Citation

CBC 1121B.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost:

640

Maximum Estimated Cost:

640

Record Number

157

Priority:

Path of Travel Finding:

The leading edge of the wall-mounted box outside of the Livestock Office is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Object Full Rec

Install side extensions, modify, relocate, or lower the box so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).

Citation

CBC 1121B.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 640 171

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 44 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The leading edge of the fire extinguisher at the north end of the Grandstands, Building 6, at the north entrance to Building 3, the east entrance to Building 5, in the Stable Office, the break room in the Administration Building and in Building 4 is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Object Full Rec

Consult with the local fire marshal to determine the feasibility of moving the fire extinguishers to new locations (such as in a corner) to eliminate the protrusion into the primary path of travel. Otherwise, install side extensions or wing walls on each fire extinguisher throughout the facility so that the leading edges are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).

Citation

CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

173

Priority:

Path of Travel Finding:

The leading edge of the wall-mounted counter in the Grandstands is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Object Full Rec

Install side extensions, modify, relocate, or lower the counter so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).

Citation

CBC 1121B.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 640 1177

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 45 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The beams throughout the Grandstand protrude into the primary path of travel by providing a hazardous height range greater than 27 inches and less than 80 inches from the floor.

Alternative Rec: (Where Available)

*

Protruding Objects Full Rec

Install side extensions or other permanent devices that extend lower than 27 inches from the floor surface to prevent it from protruding into the primary path of travel.

Citation

CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 640 146

Priority:

Path of Travel Finding:

The leading edge of each display case in the Winners Gaming and Sports Emporium is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Objects Full Rec

Install side extensions or wing walls on each display case so that its leading edge is less than 27 inches from the floor.

Citation

CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

4

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 2560 165

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 46 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The leading edge of the electrical outlets in L-2 and L-3 is more than 4 inches from the wall and less than 80 inches above the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Objects Full Rec

Modify or relocate the electrical outlets so that the leading edge protrudes less than 4 inches from the wall and is at least 80 inches above the floor (see CBC 1121B.1 and ADAAG 4.4).

Citation

CBC 1121B.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 640 168

Priority:

Path of Travel Finding:

The leading edge of the display cases in Building 6 is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.

Alternative Rec: (Where Available)

*

Protruding Objects Full Rec

Install side extensions or wing walls on the display case so that its leading edge is less than 27 inches from the floor.

Citation

CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

640 640 218

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 47 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The sink in Building 7 is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in Building 7 Full Rec

Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

420 420 138

Priority:

Path of Travel Finding:

The pipes under the sink in Building 7 do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in Building 7 Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 139

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 48 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The faucet controls on the sink in Building 7 require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Sink in Building 7 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in Building 7. Lever-operated, pushtype, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 140

Priority:

Path of Travel Finding:

The sink in Building 8 is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in Building 8 Full Rec

Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

420 420 185

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 49 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The pipes under the sink in Building 8 do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in Building 8 Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 186

Priority:

Path of Travel Finding:

The faucet controls on the sink in Building 8 require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Sink in Building 8 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in Building 8. Lever-operated, pushtype, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 187

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 50 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The sink in the Administration Office is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in the Administration Office Full Rec

Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

420

Maximum Estimated Cost:

420

Record Number

182

Priority:

Path of Travel Finding:

The pipes under the sink in the Administration Building do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in the Administration Office Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 183

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 51 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The sink in the Jockey's Quarters is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in the Jockeys Quarters Full Rec

Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

420

Maximum Estimated Cost:

420

Record Number

155

Priority:

Path of Travel Finding:

The pipes under the sink in the Jockey's Quarters do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in the Jockeys Quarters Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 156

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 52 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The knee clearance space under the sink designated to be accessible in the Jockey's Quarters is less than 27 inches.

Alternative Rec: (Where Available)

*

Sink in the Jockey's Quarters Full Rec

Raise or replace the sink designated to be accessible in the restroom to provide at least 27 inches of clear knee space and a minimum of nine inches clear toe space.

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

206

Priority:

Path of Travel Finding:

The faucet controls on the sink in the Jockey's Quarters require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Sink in the Jockey's Quarters Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Jockey's Quarters. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 207

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 53 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The height of the counter surface of the sink designated to be accessible in the Linden Lions Building is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in the Linden Lion's Building Full Rec

Relocate the sink designated to be accessible in the room to provide a maximum counter surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

208

Priority:

Path of Travel Finding:

The pipes under the sink in the Linden Lion's Building do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in the Linden Lion's Building Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 209

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 54 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The faucet controls on the sink in the Linden Lion's Building require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Sink in the Linden Lion's Building Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Linden Lion's Building. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

210

Priority:

Path of Travel Finding:

The knee clearance space under the sink designated to be accessible in the Maintenance Building is less than 27 inches.

Alternative Rec: (Where Available)

*

Sink in the Maintenance Building (East End) Full Rec

Raise or replace the sink designated to be accessible to provide at least 27 inches of clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

161

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 55 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The height of the counter surface of the sink designated to be accessible in the Maintenance Building is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in the Maintenance Building (East End) Full Rec

Relocate the sink designated to be accessible in the room to provide a maximum counter surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

162

Priority:

Path of Travel Finding:

The faucet controls on the sink in the Maintenance Building require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Sink in the Maintenance Building (East End) Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Maintenance Building. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 163

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 56 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The sink in the Maintenance Office is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Sink in the Maintenance Office Full Rec

Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

420

Maximum Estimated Cost:

420

Record Number

191

Priority:

Path of Travel Finding:

The pipes under the sink in the Maintenance Office do not provide protection against contact.

Alternative Rec: (Where Available)

*

Sink in the Maintenance Office Full Rec

Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 192

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 57 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The mat at the east entrance to the Stable Office does not adhere to the underlying floor surface and creates a hazardous path of travel.

Alternative Rec: (Where Available)

*

Stable Office (East Entrance) Full Rec

Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.

Citation

CBC 1124B.3; ADAAG 4.5.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

659

Maximum Estimated Cost:

659

Record Number

160

Priority:

Path of Travel Finding:

The mat at the entrance to the Stable Office does not adhere to the underlying floor surface and creates a hazardous path of travel.

Alternative Rec: (Where Available)

*

Stable Office Main Entrance Full Rec

Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.

Citation

CBC 1124B.3; ADAAG 4.5.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

659 659 158

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 58 of 542

Facility Name: San Joaquin Fairgrounds Path of Travel Finding:

The knee space at the tables in the gambling area is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Modify or replace one of the tables in the gambling area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

174

Maximum Estimated Cost:

174

Record Number

1160

Priority:

Path of Travel Finding:

The knee space at the tables in the Champion's Section is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Modify or replace one of the tables in the Champion's Section to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1168

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 59 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The slope of the ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to Building 7 Full Rec

Modify the run of the ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

225

Priority:

Ramps Finding:

The width of the run of the ramp is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to Building 7 Full Rec

Widen the run of the ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).

Citation

CBC 1133B.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

7500

Maximum Estimated Cost:

7500

Record Number

226

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 60 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

There is only one handrail provided on the ramp. There are no 12-inch extensions beyond the top and bottom of the ramp.

Alternative Rec: (Where Available)

*

Exterior Ramp to Building 7 Full Rec

Install a handrail on each side of the ramp that provide a continuous and smooth gripping surface diameter between 1 1/4 inches to 1 7/8 inches, mounted at a height between 34 inches and 38 inches and shall be at a distance no less than 1 1/2 inches from the adjacent wall. The ends of the handrail shall extend 12 inches in a parallel height from the top and bottom of the ramp and return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1200

Maximum Estimated Cost:

1200

Record Number

227

Priority:

Ramps Finding:

The slope of the concrete ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Grandstands Full Rec

Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

223

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 61 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The ends of the handrails end abruptly.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Grandstands Full Rec

Replace the handrails on each side of the ramp that return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

1320

Maximum Estimated Cost:

1320

Record Number

224

Priority:

Ramps Finding:

The slope of the bottom run of the metal ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec

Modify the bottom run of the metal ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

238

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 62 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The width of the run of each run of the metal ramp is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec

Widen each run of the metal ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).

Citation

CBC 1133B.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

7500

Maximum Estimated Cost:

7500

Record Number

239

Priority:

Ramps Finding:

The ramp changes direction more than 30 degrees. The length of the intermediate turn landing on the ramp is less than 72 inches. The width of the intermediate landing is less than 60 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec

Modify or replace the intermediate turn landing on the ramp to provide at least 72 inches in length in the direction of the run of the ramp and 60 inches in width (see CBC 1133B.5.4.6 and ADAAG 4.8.4).

Citation

CBC 1133B.5.4; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

0 1872 240

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 63 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The handrails are mounted at a height less than 34 inches. There are no 12-inch extensions beyond the top and bottom right of the ramp. The gripping surface of the handrails are interrupted by posts.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec

Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

1320

Maximum Estimated Cost:

1320

Record Number

241

Priority:

Ramps Finding:

The slope of the bottom run of the metal ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec

Modify the bottom run of the metal ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

242

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 64 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The width of the run of the metal ramp is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec

Widen the run of the metal ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).

Citation

CBC 1133B.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

7500

Maximum Estimated Cost:

7500

Record Number

243

Priority:

Ramps Finding:

The ramp changes direction more than 30 degrees. The length of the intermediate turn landing on the ramp is less than 72 inches. The width of the intermediate landing is less than 60 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec

Modify or replace the intermediate turn landing on the ramp to provide at least 72 inches in length in the direction of the run of the ramp and 60 inches in width (see CBC 1133B.5.4.6 and ADAAG 4.8.4).

Citation

CBC 1133B.5.4; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

0 1872 244

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 65 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The handrails are mounted at a height less than 34 inches. There are no 12-inch extensions beyond the top and bottom right of the ramp. The gripping surface of the handrails are interrupted by posts.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec

Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

1320

Maximum Estimated Cost:

1320

Record Number

245

Priority:

Ramps Finding:

The slope of the concrete ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Milk Parlor Full Rec

Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

235

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 66 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

There is no top landing on the ramp.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Milk Parlor Full Rec

Modify or replace the ramp so that it has a top landing complying with CBC 1133B.4.1 and ADAAG 4.8.4.

Citation

CBC 1133B.4.1; ADAAG 4.8.4(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost:

1872

Record Number

236

Priority:

Ramps Finding:

The handrails are mounted at a height greater than 38 inches. There are no 12-inch extensions beyond the top right and bottom of the ramp. The gripping surface of the right handrail is interrupted by a post.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Milk Parlor Full Rec

Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

1320

Maximum Estimated Cost:

1320

Record Number

237

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 67 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The slope of the concrete ramp is greater than 8.33%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec

Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).

Citation

CBC 1133B.5.3; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

4920

Maximum Estimated Cost:

4920

Record Number

228

Priority:

Ramps Finding:

The distance between the latch side of the door on a side approach from the top landing is less than 42 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec

Modify or replace the top landing on the ramp to provide at least 42 inches distance between the latch side of the door and the side of the landing to accommodate the required side approach to the entrance door (see CBC 1133B.5.4.2 and ADAAG 4.8.4(2)).

Citation

CBC 1133B.4.2; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

48 Square Feet

Minimum Estimated Cost:

1872

Maximum Estimated Cost:

1872

Record Number

229

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 68 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

There are no 12-inch extensions beyond the top right and bottom of the ramp. The ends of the right handrail end abruptly.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec

Weld pipe extensions on the handrails of the ramp so that they continue 12 inches beyond the end of the ramp parallel to the ground surface and return smoothly to the post or wall (see CBC 1133B.5.5 and ADAAG 4.8.5).

Citation

CBC 1133B.5.5; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

2400

Maximum Estimated Cost:

2400

Record Number

230

Priority:

Ramps Finding:

The width of the run of the wood ramp is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec

Widen the run of the wood ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).

Citation

CBC 1133B.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

8383

Maximum Estimated Cost:

8383

Record Number

231

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 69 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The length of the top landing on the ramp is less than 60 inches.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec

Modify or replace the top landing on the ramp to provide a top landing that exceeds 60 inches in length (see CBC 1133B.5.4.2 and ADAAG 4.8.4(2)).

Citation

CBC 1133B.4.2; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

48 Square Feet

Minimum Estimated Cost:

1872

Maximum Estimated Cost:

1872

Record Number

232

Priority:

Ramps Finding:

The slope of the bottom landing is greater than 2%.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec

Resurface the bottom landing of the ramp to provide a level surface not exceeding a slope greater than 2% (see CBC 1133B.5.4.5).

Citation

CBC 1133B.4.5; ADAAG 4.8

Minimum Quantity

1

Maximum Quantity:

1

Unit:

48 Square Feet

Minimum Estimated Cost:

1872

Maximum Estimated Cost:

1872

Record Number

233

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 70 of 542

Facility Name: San Joaquin Fairgrounds Ramps Finding:

The handrails are mounted at a height less than 34 inches. The 12-inch extensions beyond the bottom of the ramp are not parallel to the ground surface.

Alternative Rec: (Where Available)

*

Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec

Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.

Citation

CBC 1133B.5.5; ADAAG 4.8.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

60 Linear Feet

Minimum Estimated Cost:

1320

Maximum Estimated Cost:

1320

Record Number

234

Priority:

Platform Lifts Finding:

There is a platform lift at the Grandstands. The platform lift provides accessible vertical path of travel to the bleachers. The platform lift is capable of providing independent operation.

Alternative Rec: (Where Available)

*

Platform Lift at the Grandstands Full Rec

Platform lifts must be capable of independent operation. Platform lifts shall not modified in any manner or serve as an accessible means of egress. Platform lifts shall comply with CBC 1105.3, CBC 1104.1.4, ADAAG 4.11 and ASME A17.1 Safety Code for Elevators and Escalators, Section XX, 1990.

Citation

CBC 1105.3; CBC 1104.1.4; ADAAG 4.11

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 246

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 71 of 542

Facility Name: San Joaquin Fairgrounds Platform Lifts Finding:

There is no level landing provided at the entrance to the platform lift.

Alternative Rec: (Where Available)

*

Platform Lift at the Grandstands Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

247

Priority:

Stairs Finding:

There is no detectable striping on each tread of the exterior stairway.

Alternative Rec: (Where Available)

*

Exterior Stairs to Building 7 Full Rec

Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.

Citation

CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

144 144 255

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 72 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

The width of the exterior stairway is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Stairs to Building 7 Full Rec

Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).

Citation

CBC 1006.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4672

Maximum Estimated Cost:

4672

Record Number

256

Priority:

Stairs Finding:

There is only one handrail on the stairway. The handrail does not provide 12-inch extensions beyond the top treads.

Alternative Rec: (Where Available)

*

Exterior Stairs to Building 7 Full Rec

Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.

Citation

CBC 1133B.4.2; ADAAG 4.9.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

24 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

528 528 257

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 73 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

The top riser on the stairway is open.

Alternative Rec: (Where Available)

*

Exterior Stairs to Building 7 Full Rec

Close the riser openings on the stairway (see CBC 1006.16.3 and ADAAG 4.9.2). Open risers are not permitted.

Citation

CBC 1133B.4.5.3; ADAAG 4.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

480 480 258

Priority:

Stairs Finding:

There is no detectable striping on each tread of the exterior stairway.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec

Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.

Citation

CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

144 144 261

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 74 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

The width of the exterior stairway is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec

Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).

Citation

CBC 1006.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4672

Maximum Estimated Cost:

4672

Record Number

262

Priority:

Stairs Finding:

The handrails do not provide 12-inch extensions beyond the top and bottom treads. The diameter of the gripping surface is greater than 1 7/8 inches. The handrails are mounted at a height less than 34 inches.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec

Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.

Citation

CBC 1133B.4.2; ADAAG 4.9.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

24 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

528 528 263

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 75 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

Detectable striping is provided on the top two and bottom two treads only.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Grandstands Full Rec

Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.

Citation

CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5

Minimum Quantity

1

Maximum Quantity:

6

Unit:

Each

Minimum Estimated Cost:

144

Maximum Estimated Cost:

864

Record Number

252

Priority:

Stairs Finding:

The handrails do not provide 12-inch extensions beyond the top and bottom treads.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Grandstands Full Rec

Install handrails on each side of stairway that provide 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall.

Citation

CBC 1133B.4.2; ADAAG 4.9.4

Minimum Quantity

1

Maximum Quantity:

6

Unit:

24 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

528 3168 253

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 76 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

Two of the exterior stairways do not provide handrails on each side of the bottom run of the stairway.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Grandstands Full Rec

Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.

Citation

CBC 1133B.4.2; ADAAG 4.9.4

Minimum Quantity

1

Maximum Quantity:

2

Unit:

24 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost:

528 1056

Record Number

254

Priority:

Stairs Finding:

There is no detectable striping on each tread of the exterior stairway.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Office at the Stockton Motorplex Full Rec

Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.

Citation

CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

144 144 248

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 77 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

The width of the exterior stairway is less than 48 inches.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Office at the Stockton Motorplex Full Rec

Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).

Citation

CBC 1006.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4672

Maximum Estimated Cost:

4672

Record Number

249

Priority:

Stairs Finding:

The handrails do not provide 12-inch extensions beyond the bottom treads. The handrails are mounted at a height greater than 38 inches.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Office at the Stockton Motorplex Full Rec

Install handrails on each side of stairway that provide 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.

Citation

CBC 1133B.4.2; ADAAG 4.9.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

24 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

528 528 250

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 78 of 542

Facility Name: San Joaquin Fairgrounds Stairs Finding:

The risers on the stairway are open.

Alternative Rec: (Where Available)

*

Exterior Stairs to the Office at the Stockton Motorplex Full Rec

Close the riser openings on the stairway (see CBC 1006.16.3 and ADAAG 4.9.2). Open risers are not permitted.

Citation

CBC 1133B.4.5.3; ADAAG 4.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

480 480 251

Priority:

Doors Finding:

The bottom 10 inches of the door from the lobby to the east wing does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Administration Office Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 264

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 79 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

There is less than 12 inches of latch side clearance from the push side of the entrance door to the office at the south east end of the Administration Office.

Alternative Rec: (Where Available)

*

Administration Office Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

265

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 1 (East Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 268

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 80 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 1 (East Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

269

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 1 (North Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 266

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 81 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 1 (North Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

267

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 1 (South Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 332

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 82 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 1 (South Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

333

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 1 (West Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 270

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 83 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 1 (West Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 271

Priority:

Doors Finding:

The interior passage door next to the restrooms in Building 2 has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Building 2 Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 285

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 84 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door to the restrooms in Building 2 does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 2 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

286

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 2 (North Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 336

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 85 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stops.

Alternative Rec: (Where Available)

*

Building 2 (North Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

337

Priority:

Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 2 (South Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 338

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 86 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 3 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 324

Priority:

Doors Finding:

The bottom 10 inches of the exterior doors at Building 4 do not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 4 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 298

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 87 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the exterior doors at Building 5 do not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 5 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 295

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 6 Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 292

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 88 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Building 6 (East Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 327

Priority:

Doors Finding:

Exterior passage doors have round doorknobs, which require twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

834 834 279

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 89 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 280

Priority:

Doors Finding:

The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Building 8 Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

834 834 272

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 90 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Building 8 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 273

Priority:

Doors Finding:

There is less than 12 inches of clearance on the latch side of the exterior entrance door.

Alternative Rec: (Where Available)

*

Building 8 Full Rec

Provide at least 12 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 276

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 91 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The landing at the entrance door does not provide sufficient clear floor space.

Alternative Rec: (Where Available)

*

Door at L-1 Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

142

Priority:

Doors Finding:

The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Exterior Door to the Gym at the Stable Office Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

834 834 314

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 92 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Exterior Door to the North West Office Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 331

Priority:

Doors Finding:

The height of the threshold at the entrance door is greater than 1/2 inch.

Alternative Rec: (Where Available)

*

FFA Office Full Rec

Modify or replace the threshold to provide a smooth transition. The threshold should not exceed a beveled 1/2 inch. Provide a 60 inch level landing in the direction of the door swing.

Citation

CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2500

Maximum Estimated Cost:

2500

Record Number

290

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 93 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

There is less than 24 inches of clearance on the latch side of the exterior entrance door.

Alternative Rec: (Where Available)

*

Flats BBQ Full Rec

Provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 319

Priority:

Doors Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 322

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 94 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

323

Priority:

Doors Finding:

The interior passage door to the employee restroom has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Interior Door at the South End of the Grandstands Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 291

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 95 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Interior Door in Building 8 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 277

Priority:

Doors Finding:

The interior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Interior Door in Building 8 Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 278

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 96 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The interior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Interior Door in L-1 Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

287

Priority:

Doors Finding:

There is less than 18 inches of latch side clearance from the pull side of the interior entrance door from the restrooms to the east wing.

Alternative Rec: (Where Available)

*

Interior Door in the Stable Office Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door from the pull side (see ADAAG 4.13.6 and Figure 25).

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 318

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 97 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Interior Door to the Gym in the Stable Office Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

312

Priority:

Doors Finding:

There is less than 18 inches of latch side clearance from the pull side of the interior entrance door.

Alternative Rec: (Where Available)

*

Interior Door to the Gym in the Stable Office Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door from the pull side (see ADAAG 4.13.6 and Figure 25).

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 313

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 98 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The interior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Interior Door to the Laundry Room in the Jockey's Quarters Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 328

Priority:

Doors Finding:

The bottom 10 inches of the interior doors in the Jockey's Quarters does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 299

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 99 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The exterior door is set in an alcove. There is less than 24 inches of clearance on the latch side of the exterior entrance door.

Alternative Rec: (Where Available)

Install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.

Jockey's Quarters Full Rec

Povide at least 24 inches between the latch side of the door and the side wall of the alcove at the primary entrance. Otherwise install a compliant automatic door opening device.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1921

Maximum Estimated Cost:

0

Record Number

329

Priority:

Doors Finding:

The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Jockey's Quarters (North Entrance) Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

834 834 300

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 100 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

There is less than 24 inches of clearance on the latch side of the exterior entrance door.

Alternative Rec: (Where Available)

*

Jockey's Quarters (North Entrance) Full Rec

Provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 303

Priority:

Doors Finding:

The interior passage door has a round doorknob, which requires twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Livestock Office Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 288

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 101 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Livestock Office Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

289

Priority:

Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Main Office (South Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 321

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 102 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

Interior passage doors have round doorknobs, which require twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Maintenance Office Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 330

Priority:

Doors Finding:

Exterior passage doors at each entrance to the Stable Office have round doorknobs, which require twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

834 834 306

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 103 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 307

Priority:

Doors Finding:

The height of the threshold at the entrance door is greater than 1/2 inch.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Modify or replace the threshold to provide a smooth transition. The threshold should not exceed a beveled 1/2 inch. Provide a 60 inch level landing in the direction of the door swing.

Citation

CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2500

Maximum Estimated Cost:

2500

Record Number

310

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 104 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

Interior passage doors have round doorknobs, which require twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

311

Priority:

Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Stable Office (East Entrance) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 317

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 105 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

Exterior passage doors have round doorknobs, which require twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Stable Office (West Entrance) Full Rec

Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

834

Maximum Estimated Cost:

834

Record Number

315

Priority:

Doors Finding:

The landing at the entrance door does not provide sufficient clear floor space.

Alternative Rec: (Where Available)

*

Stable Office (West Entrance) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 316

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 106 of 542

Facility Name: San Joaquin Fairgrounds Doors Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Winners Gaming and Sports Emporium Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

320

Priority:

Counters Finding:

The height of the Administration Office reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Administration Office Full Rec

Lower at least a 36 inch wide portion of the Administration Office reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 339

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 107 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the Building 3 reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Building 3 Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

343

Priority:

Counters Finding:

The height of the Building 7 reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 357

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 108 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the counter at the scale shop is greater than 34 inches.

Alternative Rec: (Where Available)

*

Delta Speedway Full Rec

Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

341

Priority:

Counters Finding:

The height of the Fitness Center reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Fitness Center (West Entrance) Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 361

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 109 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the Fitness Center reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Fitness Center in the Stable Office Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

349

Priority:

Counters Finding:

The height of the betting counter at the south end of the Grandstands is greater than 34 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 359

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 110 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the betting counters is greater than 34 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower at least a 36 inch wide portion of the counters to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

362

Priority:

Counters Finding:

The height of the reception counter in L-1 is greater than 34 inches.

Alternative Rec: (Where Available)

*

L-1 Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 354

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 111 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the exterior counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Livestock Office Full Rec

Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

344

Priority:

Counters Finding:

The height of the Security Office reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Security Office Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 356

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 112 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the reception counter at the east entrance to the Stable Office is greater than 34 inches.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Lower at least a 36 inch wide portion of the sales counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

348

Priority:

Counters Finding:

The height of the Stable Office reception counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 350

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 113 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the ticket counters at the main entrance to the Fairgrounds is greater than 36 inches.

Alternative Rec: (Where Available)

*

Ticket Counters at the Main Entrance Full Rec

Lower one of the ticket counters to a height no greater than 36 inches above the ground (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost:

129

Maximum Estimated Cost:

129

Record Number

190

Priority:

Counters Finding:

The height of the change counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Winners Gaming and Sports Emporium Full Rec

Lower at least a 36 inch wide portion of the change counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 340

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 114 of 542

Facility Name: San Joaquin Fairgrounds Counters Finding:

The height of the Champions counters is greater than 34 inches.

Alternative Rec: (Where Available)

*

Winners Gaming and Sports Emporium Full Rec

Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).

Citation

CBC 1122B.4; ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 345

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Administration Office Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 366

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 115 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Administration Office Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 367

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 1 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 334

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 116 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 1 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 335

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 2 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 283

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 117 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 2 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 284

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 3 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 325

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 118 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 3 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 326

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 4 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 370

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 119 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 4 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 371

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 5 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 216

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 120 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 5 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 217

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 6 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 293

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 121 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 6 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 294

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 281

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 122 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 7 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 282

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Building 8 Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 274

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 123 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Building 8 Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

275

Priority:

Visual and Audible Communications Finding:

There is no directional signage to the accessible entrance from the public right of way or other common use areas.

Alternative Rec: (Where Available)

*

Directional Signage Full Rec

Install directional signage to each common area complying with CBC 1117B.5 and ADAAG 4.30.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 379

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 124 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

FFA Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

368

Priority:

Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

FFA Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 369

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 125 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Flats BBQ Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

374

Priority:

Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Flats BBQ Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 375

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 126 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

301

Priority:

Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 302

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 127 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Linden Lions Building Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

372

Priority:

Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Linden Lions Building Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 373

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 128 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Main Office Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

376

Priority:

Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Main Office Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 377

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 129 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There are four pay telephones at the facility, located in the Winners Gaming and Sports Emporium, outside of the men's restroom next to the Livestock area, next to the Stable Office and at the west entrance of Building 2.

Alternative Rec: (Where Available)

*

Pay Telephone Full Rec

Contact the telephone company that owns the pay telephone regarding following items that do not comply with ADA requirements. The telephone company is responsible for ADA compliance, if the facility has no ownership in the pay telephone.

Citation

CBC 1117B.2.1; ADAAG 4.31

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

363

Priority:

Visual and Audible Communications Finding:

There is no electrical outlet within or adjacent to the telephone enclosure.

Alternative Rec: (Where Available)

*

Pay Telephone at the West Entrance to Building 2 Full Rec

Electrical outlets within or adjacent to the telephone enclosure are required at pay telephones designed to accommodate a portable text telephone.

Citation

CBC 1117B.2.9; ADAAG 4.31

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 365

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 130 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

There is no electrical outlet within or adjacent to the telephone enclosure.

Alternative Rec: (Where Available)

*

Pay Telephone Outside of the Men's Restroom at the Livestock Area Full Rec

Electrical outlets within or adjacent to the telephone enclosure are required at pay telephones designed to accommodate a portable text telephone.

Citation

CBC 1117B.2.9; ADAAG 4.31

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

364

Priority:

Visual and Audible Communications Finding:

There is no directional signage to the accessible restrooms outside of Building 1.

Alternative Rec: (Where Available)

*

Restrooms Outside of Building 1 Full Rec

Install directional signage to the accessible restrooms outside of Building 1 complying with CBC 1117B.5 and ADAAG 4.30.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 188

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 131 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

Rooms do not have accessible signage mounted on the wall adjacent to the latch side of the doors.

Alternative Rec: (Where Available)

*

Room Signage Full Rec

Install accessible signage identifying each room on the wall adjacent to the latch side of the doorway centered at 60 inches above the finished floor. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door. Signs shall include raised UPPERCASE letters/numbers between 5/8 inch and 2 inches in height and Grade 2 Braille characters. Color and finish shall comply with CBC 1117B.5 and ADAAG 4.30.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 378

Priority:

Visual and Audible Communications Finding:

The contact device in the Winners Gaming and Sports Emporium does not have accessible signage mounted on the wall adjacent to the device.

Alternative Rec: (Where Available)

*

Service Bell in the Winners Gaming and Sports Emporium Full Rec

Install compliant informational signage on the wall adjacent to the contact device complying with CBC 1117B.5 and ADAAG 4.30.5.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 180

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 132 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The height of the service bell is greater than 48 inches above the floor for an accessible forward approach reach height.

Alternative Rec: (Where Available)

*

Service Bell in the Winners Gaming and Sports Emporium Full Rec

Lower the service bell to provide an accessible forward approach reach height no greater than 48 inches above the finished floor.

Citation

CBC 1118B.5; ADAAG 4.2.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 181

Priority:

Visual and Audible Communications Finding:

There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).

Citation

CBC 1117B.5.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 308

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 133 of 542

Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:

The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.

Alternative Rec: (Where Available)

*

Stable Office Full Rec

Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.

Citation

CBC 1117B.5; ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

309

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 624

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 134 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

625

Priority:

Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

626

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 135 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

627

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

628

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 136 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

629

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 630

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 137 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

631

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

632

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 138 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

633

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 634

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 139 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

635

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

636

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 140 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

637

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 638

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 141 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

639

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 640

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 142 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 852

Priority:

Restrooms Finding:

The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 853

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 143 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bar in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

854

Priority:

Restrooms Finding:

The location of the toilet paper dispenser in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Remount the toilet paper dispenser in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 855

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 144 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

856

Priority:

Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 857

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 145 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.

Citation

CBC 1115B.9.4; ADAAG 4.18.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 858

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

859

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 146 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

860

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Faculty Unisex Restroom at the Grandstands (South End) Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 861

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 147 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

773

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 774

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 148 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

775

Priority:

Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 776

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 149 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are six stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

777

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

778

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 150 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

779

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 780

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 151 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

781

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 783

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 152 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

784

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

785

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 153 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

786

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 787

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 154 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

788

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 2 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 789

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 155 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

520

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 521

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 156 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 12 inches of latch side clearance from the push side of the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

522

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 523

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 157 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

524

Priority:

Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 525

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 158 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

526

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 527

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 159 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

528

Priority:

Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 529

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 160 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

530

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is nonaccessible and requires the use of foot controls to operate.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 531

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 161 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

532

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 533

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 162 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

534

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

535

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 163 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

536

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 537

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 164 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

538

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 4 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 539

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 165 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

961

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 962

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 166 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

963

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 964

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 167 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor. The flush control valve on the urinal is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

965

Priority:

Restrooms Finding:

There is less than 30 inches by 48 inches of clear floor space provided in front of the urinal in the restroom to allow an accessible forward approach.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

The minimum clear floor space in front of the urinal designated to be accessible in the restroom shall be at least 30 inches by 48 inches to provide an accessible forward approach (see CBC 1115B.9.4 and ADAAG 4.18.3). Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the urinal.

Citation

CBC 1115B.9.4; ADAAG 4.18.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 966

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 168 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The latch side approach to the stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

967

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

968

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 169 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

969

Priority:

Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 970

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 170 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

971

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

973

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 171 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no clear floor space provided in front of the seat cover dispenser.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

974

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 975

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 172 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Building 5 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

976

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 431

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 173 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The door opening force for the interior entrance door to the restroom is greater than 5 pounds.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Adjust the closer on the interior entrance door to the restroom to a maximum door opening force of 5 pounds (see CBC 1133B.2.5.1 and ADAAG 4.13.11).

Citation

CBC 1133B.2.5.1; ADAAG 4.13.11

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

5

Maximum Estimated Cost:

5

Record Number

432

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

433

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 174 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

434

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 435

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 175 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

436

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

437

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 176 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no clear floor space provided in front of the seat cover dispenser.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

438

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

439

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 177 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Flats BBQ Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

440

Priority:

Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 559

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 178 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

560

Priority:

Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 561

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 179 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

562

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 563

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 180 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

564

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

565

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 181 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

566

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 567

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 182 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

568

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 569

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 183 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

570

Priority:

Restrooms Finding:

There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn 2 Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

571

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 184 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

1043

Priority:

Restrooms Finding:

The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

1024 1024 1044

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 185 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1045

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1046

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 186 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

1047

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost: Record Number

1707 1049

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 187 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1050

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1051

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 188 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

1052

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 1053

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 189 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

1054

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1055

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 190 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1056

Priority:

Restrooms Finding:

The men's restroom provides two private shower stalls. There are no accessible shower stalls provided in the men's restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the men's restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost: Record Number

2853 1057

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 191 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

1058

Priority:

Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the showers from the pull side.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn N Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1059

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 192 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

1060

Priority:

Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 1061

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 193 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1062

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1063

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 194 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

1064

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost: Record Number

1707 1066

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 195 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1067

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1068

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 196 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

1069

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 1070

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 197 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1071

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1072

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 198 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The women's restroom provides two private shower stalls. There are no accessible shower stalls provided in the women's restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the women's restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

1101

Priority:

Restrooms Finding:

The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1102

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 199 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the showers in the restroom from the pull side.

Alternative Rec: (Where Available)

*

Men's Restroom at Horse Barn Q Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

1103

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 687

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 200 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

688

Priority:

Restrooms Finding:

The door opening force for the exterior door is greater than 5 pounds of force.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).

Citation

CBC 1133B.2.5; ADAAG 4.13.11

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

5

Maximum Estimated Cost: Record Number

5 689

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 201 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

690

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 691

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 202 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

692

Priority:

Restrooms Finding:

The distance from the end of the side grab bars to the back wall in the stall designated to be accessible in the restroom is greater than 12 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 693

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 203 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

694

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

695

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 204 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

696

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 697

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 205 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

698

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at Livestock Building 1 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 699

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 206 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage indicating accessibility on the latch side of the entry door of the restroom does not include Braille or raised lettering and is not centered at 60 inches above the floor surface. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

842

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 843

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 207 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

844

Priority:

Restrooms Finding:

The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 845

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 208 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

846

Priority:

Restrooms Finding:

The distance from the end of the side grab bar to the back wall in the stall designated to be accessible in the restroom is greater than 12 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 847

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 209 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

849

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 850

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 210 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Carnival Area Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

851

Priority:

Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 1104

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 211 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are 12 stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost: Record Number

4000 1105

Priority:

Restrooms Finding:

The latch side approach to the stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1106

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 212 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1107

Priority:

Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 1108

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 213 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost: Record Number

448 1109

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 1110

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 214 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost: Record Number

1143 1112

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1113

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 215 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost: Record Number

1286 1114

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 1115

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 216 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1116

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1117

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 217 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the hand dryer in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Delta Speedway (West End) Full Rec

Relocate the hand dryer in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1118

Priority:

Restrooms Finding:

There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 862

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 218 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

863

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 864

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 219 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

865

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

866

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 220 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

867

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 868

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 221 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the right grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Remount the right grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

869

Priority:

Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 870

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 222 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

871

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

872

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 223 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

873

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 874

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 224 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (East End) Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

875

Priority:

Restrooms Finding:

There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

The restroom is designated accessible and should be made accessible for the facility Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 876

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 225 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 24 inches of clearance on the latch side of the exterior entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

877

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 878

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 226 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no level landing provided at the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Provide a level and clear landing at least 60 inches in length in the direction of the door swing.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

879

Priority:

Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall. The flush control valve on the urinal is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 880

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 227 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The length of the back grab bar in the stall designated to be accessible of the restroom is less than 36 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Replace the back grab bar in the stall designated to be accessible of the restroom with a 36-inch back grab bar complying with ADAAG 4.26 and CBC 1115B.8. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

881

Priority:

Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 882

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 228 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

883

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 884

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 229 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

885

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 886

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 230 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Grandstands (North End) Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

887

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface and does not include the ISA symbol.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 1084

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 231 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

1085

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 1086

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 232 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

1087

Priority:

Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1088

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 233 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

1089

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost: Record Number

4000 1090

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 234 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

1091

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost: Record Number

1707 1093

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 235 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1094

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1095

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 236 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

1096

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 1097

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 237 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

1098

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1099

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 238 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Maintenance Facility Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1100

Priority:

Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 583

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 239 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The door opening force for the exterior door is greater than 5 pounds of force.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).

Citation

CBC 1133B.2.5; ADAAG 4.13.11

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

5

Maximum Estimated Cost:

5

Record Number

584

Priority:

Restrooms Finding:

The height of the side and back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 585

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 240 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

586

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

587

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 241 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the RV Park Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

588

Priority:

Restrooms Finding:

There is signage indicating accessibility on the entry door to the restroom. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1127

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 242 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost: Record Number

951 1128

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost: Record Number

4000 1129

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 243 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost: Record Number

1143 1130

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1131

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 244 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

1132

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 494

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 245 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

750

Maximum Estimated Cost:

750

Record Number

495

Priority:

Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 496

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 246 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

497

Priority:

Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

498

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 247 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

499

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically. The inside handle on the stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

500

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 248 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

501

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

502

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 249 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

503

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

504

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 250 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

505

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 506

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 251 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

507

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in Building 3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 508

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 252 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

380

Priority:

Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

381

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 253 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

382

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 383

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 254 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor. The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

384

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 385

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 255 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

386

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 387

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 256 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

388

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in the Administration Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 389

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 257 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is signage indicating accessibility on the entry door to the restroom. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1119

Priority:

Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 1120

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 258 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1121

Priority:

Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1122

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 259 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost: Record Number

1143 1123

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1124

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 260 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1125

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom in the Winner's Building (Champions Section) Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 1126

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 261 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

901

Priority:

Restrooms Finding:

The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

951 951 902

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 262 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

903

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 904

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 263 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

905

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

907

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 264 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

908

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 909

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 265 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

910

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 911

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 266 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

912

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 913

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 267 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

914

Priority:

Restrooms Finding:

The clear opening width of the entrance to the showers in the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Widen the entrance doorway to the showers in the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 915

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 268 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

916

Priority:

Restrooms Finding:

Showering facilities are provided, though are not required. The restroom provides two private shower stalls. There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn C Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

917

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 269 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

935

Priority:

Restrooms Finding:

The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

269 269 936

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 270 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.

Citation

CBC 1115B.9.4; ADAAG 4.18.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

937

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 938

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 271 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

939

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

941

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 272 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

942

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

943

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 273 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

944

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 945

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 274 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

946

Priority:

Restrooms Finding:

The soap dish in the shower compartment designated to be accessible in the restroom is mounted at a height greater than 40 inches above the shower floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to Horse Barn K Full Rec

Relocate the soap dish mounted in the shower compartment designated to be accessible in the restroom so that it is mounted on the same wall as the water controls at a maximum height of 40 inches above the shower floor (see CBC 1115B.6.2.4.6).

Citation

CBC 1115B.6.2.4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1200

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 275 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

700

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 701

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 276 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The urinal in the restroom is floor mounted and does not provide a tapered, elongated rim.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

702

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

703

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 277 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

704

Priority:

Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 705

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 278 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

706

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

707

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 279 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

708

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

709

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 280 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

710

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 711

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 281 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Next to the Livestock Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 712

Priority:

Restrooms Finding:

There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 888

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 282 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

889

Priority:

Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 890

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 283 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 891

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

892

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 284 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

893

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

894

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 285 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

895

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 649

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 286 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

128 Sq Ft

Minimum Estimated Cost:

1024

Maximum Estimated Cost:

1024

Record Number

650

Priority:

Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

651

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 287 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

652

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

653

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 288 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

654

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 655

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 289 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

656

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

657

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 290 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

658

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 659

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 291 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

660

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 661

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 292 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

662

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 2 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 663

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 293 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage on the entrance door is not mounted at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

509

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 510

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 294 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

511

Priority:

Restrooms Finding:

The door to the stall designated to be accessible in the restroom does not close automatically. The inside handle on the stall door designated to be accessible.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

269 269 512

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 295 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

513

Priority:

Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 514

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 296 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

515

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 516

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 297 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

517

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 518

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 298 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Restroom Outside of Building 3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

519

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 714

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 299 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

715

Priority:

Restrooms Finding:

The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1097

Maximum Estimated Cost:

1097

Record Number

716

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 300 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).

Citation

ADAAG 4.18.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

717

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

718

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 301 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

719

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 720

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 302 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

721

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

722

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 303 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

723

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

724

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 304 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

725

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 726

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 305 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

727

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 728

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 306 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no accessible showers provided.

Alternative Rec: (Where Available)

*

Men's Showers Next to the Livestock Office Full Rec

Since open showers are provided in the restroom, at least one accessible shower is required. Install an accessible shower in one of the corners with L-shaped grab bars extending along the two walls with a folding seat adjacent to the shower controls in the restroom (see CBC 1115B.6.3 and ADAAG 4.21).

Citation

CBC 1115B.6.3; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

3260

Maximum Estimated Cost:

3260

Record Number

729

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 947

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 307 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

750

Maximum Estimated Cost:

750

Record Number

948

Priority:

Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 949

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 308 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the threshold at the entrance door to the restroom is greater than 1/2 inch.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Install a ramp or threshold treatment ramp with a slope no greater than 8.33% to the entrance of the restroom complying with CBC 1133B.5 and ADAAG 4.8 when technically infeasible to modify the threshold.

Citation

ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2500

Maximum Estimated Cost:

2500

Record Number

950

Priority:

Restrooms Finding:

This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.

Citation

CBC 1115B.7.2; ADAAG 4.16.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 951

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 309 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the restroom.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

952

Priority:

Restrooms Finding:

The height of the toilet seat in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Remove or modify the toilet in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

954

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 310 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

955

Priority:

Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 956

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 311 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The lavatory in the restroom is in an enclosed cabinet, thereby preventing an accessible forward approach. The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Lavatories in restrooms must provide clear floor space in front of the lavatory for an accessible forward approach and shall provide at least 29 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the lavatory cabinet and replace with an accessible wallmounted lavatory unit.

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

420

Maximum Estimated Cost:

420

Record Number

957

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 958

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 312 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

959

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 6 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 960

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 313 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

677

Priority:

Restrooms Finding:

The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 678

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 314 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bar in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

679

Priority:

Restrooms Finding:

The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 680

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 315 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the restroom is greater than 19 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Remove or modify the toilet in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

681

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

682

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 316 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

683

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 684

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 317 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

685

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 7 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 686

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 318 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

665

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 666

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 319 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

667

Priority:

Restrooms Finding:

This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.

Citation

CBC 1115B.7.2; ADAAG 4.16.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 668

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 320 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the restroom.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

669

Priority:

Restrooms Finding:

The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 670

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 321 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

671

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 672

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 322 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

673

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 674

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 323 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

675

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 676

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 324 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

759

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 760

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 325 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

761

Priority:

Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 762

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 326 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the restroom.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

763

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

765

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 327 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

766

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 767

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 328 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

768

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 769

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 329 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

770

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 771

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 330 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at Building 8 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

772

Priority:

Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 609

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 331 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 30 inches by 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

610

Priority:

Restrooms Finding:

The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 611

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 332 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

Remount the back grab bar in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

612

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

613

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 333 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the First Aid Building Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

614

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 1030

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 334 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1031

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 1032

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 335 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

1034

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost: Record Number

1707 1035

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 336 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1036

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1037

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 337 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

1038

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 1039

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 338 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

1040

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1041

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 339 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Jockey's Quarters Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1042

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 790

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 340 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

791

Priority:

Restrooms Finding:

The location of the toilet paper dispenser in the restroom is not within 12 inches of the front edge of the toilet seat. t.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Remount the toilet paper dispenser in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 792

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 341 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

793

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

794

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 342 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

795

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 796

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 343 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom at the Livestock Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

797

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 442

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 344 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

750

Maximum Estimated Cost:

750

Record Number

443

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

444

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 345 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

445

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 446

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 346 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

447

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

448

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 347 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

449

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 450

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 348 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

451

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 452

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 349 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

453

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Unisex Restroom in the Stable Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 454

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 350 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

743

Priority:

Restrooms Finding:

The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 744

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 351 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

745

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 746

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 352 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

747

Priority:

Restrooms Finding:

The height of the left grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor. The height of the right grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 748

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 353 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The right grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

749

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

751

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 354 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

752

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 753

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 355 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

754

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 755

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 356 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

756

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 757

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 357 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 1 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

758

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door to the restroom and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 730

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 358 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are eight stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

731

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

732

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 359 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

733

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 734

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 360 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

735

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

736

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 361 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

737

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

738

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 362 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

739

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 740

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 363 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

741

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 2 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 742

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 364 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and does not include the International Symbol of Accessibility.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

977

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 978

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 365 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

979

Priority:

Restrooms Finding:

The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 980

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 366 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

981

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 982

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 367 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

983

Priority:

Restrooms Finding:

The height of the left grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor. The height of the right grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 984

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 368 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

985

Priority:

Restrooms Finding:

The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Remount or replace the toilet paper dispenser so that it does not encroach more than four inches from the face of the wall. Make sure it does not interfere with the use of the side grab bar (see ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and be mounted within 12" in front of the water closet.

Citation

DSA Access Policy 99-07

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 986

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 369 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet. The flush controls are nonaccessible and requires the use of foot controls to operate.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

987

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

988

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 370 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

989

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 990

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 371 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

991

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

992

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 372 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

993

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 994

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 373 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 4 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

995

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 540

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 374 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

750

Maximum Estimated Cost:

750

Record Number

541

Priority:

Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 542

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 375 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

543

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

544

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 376 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

545

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 546

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 377 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

547

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 548

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 378 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Building 5 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

549

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include Braille or the ISA symbol.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 1073

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 379 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1074

Priority:

Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 1075

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 380 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

1076

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 1078

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 381 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

1079

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost: Record Number

1143 1080

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 382 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1081

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost: Record Number

1286 1082

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 383 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The controls and operating mechanisms on the paper towel dispenser in the restroom require tight grasping, pinching, or twisting of the wrist and the use of two hands to operate. The height of the operating controls on the dispenser is at a height greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Flat's BBQ Full Rec

Modify or replace the paper towel dispenser in the restroom so that its controls and operating mechanisms can be operated with one hand and comply with ADAAG 4.27.4 and CBC 1117B.6.4. Make certain that the force to activate the operating controls shall be no greater than 5 pounds and that the height shall be no greater than 40 inches above the finished floor.

Citation

ADAAG 4.27.4, CBC 1117B.6.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

1083

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 572

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 384 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

573

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 574

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 385 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

575

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

576

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 386 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

577

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 578

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 387 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

579

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 580

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 388 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

581

Priority:

Restrooms Finding:

There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 1 Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

582

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 389 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage indicating accessibility at the entry to the restroom is not mounted on the latch side of the entrance door and is not centered at 60 inches above the floor surface. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

550

Priority:

Restrooms Finding:

The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

269 269 551

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 390 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

552

Priority:

Restrooms Finding:

There is less than 48 inches of clear floor space provided in front of the toilet in the restroom to allow an accessible forward approach.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

The minimum clear floor space in front of the toilet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach (see CBC 1115B.9.4 and ADAAG 4.18.3). Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the toilet.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 553

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 391 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

554

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

555

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 392 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

556

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 557

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 393 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

558

Priority:

Restrooms Finding:

The hand-held sprayer unit is mounted at a height greater than 48 inches above the finished floor. The length of the hose for the hand-held sprayer unit is less than 60 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Install a hand-held sprayer unit in the shower compartment designated to be accessible in the restroom with a hose at leapt 60 inches in length. The centerline of the hand-held sprayer unit shall be mounted within 27 inches from the rear seat edge and at a height no greater than 48 inches from the finished floor (see CBC 1115B.6.2.4.2).

Citation

ADAAG 4.21.6; CBC 1115B.6.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

385 385 1201

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 394 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

829

Priority:

Restrooms Finding:

There is less than 12 inches of latch side clearance from the push side of the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 830

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 395 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

831

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 832

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 396 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

833

Priority:

Restrooms Finding:

The left grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 834

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 397 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

835

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 836

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 398 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

837

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 838

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 399 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the rim surface of the lavatory designated to be accessible in the restroom is greater than 34 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate or replace the lavatory designated to be accessible in the restroom to provide a maximum rim surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

839

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 840

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 400 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at L-1 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

841

Priority:

Restrooms Finding:

The signage indicating accessibility on the latch side of the entry door of the restroom does not include Braille or raised lettering and is not centered at 60 inches above the floor surface. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 641

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 401 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

642

Priority:

Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 643

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 402 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

644

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

645

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 403 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

646

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 647

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 404 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Carnival Area Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

648

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 403

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 405 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are 14 stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

404

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

405

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 406 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

406

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 407

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 407 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

408

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

409

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 408 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

410

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 411

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 409 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

412

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the hand dryer in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the Delta Speedway Full Rec

Relocate the hand dryer in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 413

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 410 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage indicating accessibility at the entry door of the restroom is not mounted on the latch side of the entrance door and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

The restroom is designated accessible and should be made accessible for the facility, incorporating children's height standards set forth in the Final Rule amending ADAAG, January 13, 1998. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 615

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 616

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 411 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The door to the alternate stall designated to be accessible in the restroom does not close automatically or have accessible hardware. The inside handle on the standard stall door designated to be accessible in the restroom is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

269 269 617

Priority:

Restrooms Finding:

The height of the side grab bar in the standard stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 618

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 412 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the standard stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 619

Priority:

Restrooms Finding:

The side grab bars in the standard stall and the alternate stall designated to be accessible in the restroom do not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 620

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 413 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the standard stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

621

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 622

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 414 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom at the First Floor of the Grandstands Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

623

Priority:

Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom at the Soccer Field Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 897

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 415 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 12 inches of clearance on the latch side of the exterior entrance door from the push side.

Alternative Rec: (Where Available)

*

Women's Restroom at the Soccer Field Full Rec

Provide at least 12 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.

Citation

ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

898

Priority:

Restrooms Finding:

The door opening force for the exterior door is greater than 5 pounds of force.

Alternative Rec: (Where Available)

*

Women's Restroom at the Soccer Field Full Rec

Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).

Citation

CBC 1133B.2.5; ADAAG 4.13.11

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

5

Maximum Estimated Cost: Record Number

5 899

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 416 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface and does not include Braille or the ISA symbol.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

996

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 997

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 417 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

998

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 999

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 418 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The inside handle on the stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Install a loop or U-shaped handle immediately below the latch hardware on the door to the stall designated to be accessible in the restroom (see CBC 1115B.7.1.3 and ADAAG 4.13.9). Leveroperated or push-type mechanisms may also be used. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting.

Citation

CBC 1115B.7.1.3; ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

189

Maximum Estimated Cost:

189

Record Number

1000

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1001

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 419 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

1002

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 1003

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 420 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1004

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 1005

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 421 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

1006

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost: Record Number

1143 1007

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 422 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no clear floor space provided in front of the seat cover dispenser.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1008

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 1009

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 423 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

1010

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 1011

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 424 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

1012

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1013

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 425 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in Building 3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1014

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 480

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 426 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

481

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. There is no door on the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

482

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 427 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

483

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

484

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 428 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

485

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 486

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 429 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

392

Maximum Estimated Cost:

392

Record Number

487

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

488

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 430 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

489

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 490

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 431 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

491

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 492

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 432 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Jockey Annex Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

493

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include Braille or the ISA symbol.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 1133

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 433 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1134

Priority:

Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1135

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 434 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

1136

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 1137

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 435 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Remount or replace the toilet paper dispenser so that it does not encroach more than four inches from the face of the wall. Make sure it does not interfere with the use of the side grab bar (see ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and be mounted within 12" in front of the water closet.

Citation

DSA Access Policy 99-07

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1138

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost: Record Number

1707 1139

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 436 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1140

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost: Record Number

1286 1141

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 437 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Main Office Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1142

Priority:

Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 414

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 438 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

750

Maximum Estimated Cost:

750

Record Number

415

Priority:

Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

204 204 416

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 439 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The urinal in the restroom is floor mounted and does not provide a tapered, elongated rim. The flush control valve on the urinal is greater than 44 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.

Citation

ADAAG 4.18.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

951

Maximum Estimated Cost:

951

Record Number

417

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

418

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 440 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost:

531

Record Number

419

Priority:

Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 420

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 441 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

421

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

422

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 442 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

423

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 424

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 443 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

425

Priority:

Restrooms Finding:

The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 426

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 444 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

427

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 428

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 445 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

429

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 430

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 446 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no accessible shower stall provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the Maintenance Shop Full Rec

Since a shower stall is provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

441

Priority:

Restrooms Finding:

There is signage indicating accessibility on the entry door to the restroom in the San Joaquin Room at the Winners Gaming and Sports Emporium. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 390

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 447 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There are eight stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

391

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

392

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 448 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

393

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 394

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 449 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom in the San Joaquin Room Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

395

Priority:

Restrooms Finding:

The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 396

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 450 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

397

Priority:

Restrooms Finding:

The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 398

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 451 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost: Record Number

277 399

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

400

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 452 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

401

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom in the Winners Gaming and Sports Emporium Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 402

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 453 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage indicating accessibility is not mounted on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

468

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

469

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 454 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

470

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 471

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 455 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

127

Maximum Estimated Cost:

127

Record Number

472

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

473

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 456 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

474

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 475

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 457 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

476

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 477

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 458 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

478

Priority:

Restrooms Finding:

A showering facility is provided, though is not required. There is no accessible shower stall provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 4 Full Rec

Since a shower stall is provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

479

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 459 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage indicating accessibility is not mounted on the latch side of the entry door to the restroom. The gender use signage on the entrance door is not mounted at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

455

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

456

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 460 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

457

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 458

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 461 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

459

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

460

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 462 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

461

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 462

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 463 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

463

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 464

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 464 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

465

Priority:

Restrooms Finding:

Showering facilities are provided, though are not required. There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn 5 Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

466

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 465 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage is not mounted on the entrance door and does not include Braille or raised lettering.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

918

Priority:

Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

919

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 466 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

920

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 921

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 467 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

923

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

924

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 468 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

925

Priority:

Restrooms Finding:

The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

926

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 469 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

927

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 928

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 470 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

929

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 930

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 471 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The women's restroom provides two private shower stalls. There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the women's restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

931

Priority:

Restrooms Finding:

The clear opening width of the entrance to the showers in the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Widen the entrance doorway to the showers in the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 932

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 472 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is less than 18 inches on the latch side of the entrance door to the showers in the restroom from the pull side.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.

Citation

ADAAG 4.13.6; CBC 1133B.2.4.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

933

Priority:

Restrooms Finding:

The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.

Alternative Rec: (Where Available)

*

Women's Restroom Next to Horse Barn G Full Rec

Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.

Citation

CBC 1115B.7.1.3; ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 934

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 473 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

814

Priority:

Restrooms Finding:

The clear opening width of the entrance doorway to the restroom is less than 32 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).

Citation

ADAAG 4.13.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

750 750 815

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 474 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.

Citation

ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

204

Maximum Estimated Cost:

204

Record Number

816

Priority:

Restrooms Finding:

There are seven stalls located in the multiple accommodation restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.

Citation

CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

817

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 475 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

818

Priority:

Restrooms Finding:

There is no back grab bar in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 819

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 476 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the left grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Remount the left grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

820

Priority:

Restrooms Finding:

The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 821

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 477 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

822

Priority:

Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

823

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 478 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

824

Priority:

Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 825

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 479 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

826

Priority:

Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

39 39 827

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 480 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Next to L-2 and L-3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

828

Priority:

Restrooms Finding:

The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 598

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 481 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The door to the stall designated to be accessible in the restroom does not close automatically.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

269

Maximum Estimated Cost:

269

Record Number

599

Priority:

Restrooms Finding:

The height of the coat hook on the standard stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 600

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 482 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the side grab bar in the standard stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

601

Priority:

Restrooms Finding:

The side grab bar in the standard stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 602

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 483 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the standard stall and the alternate stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

603

Priority:

Restrooms Finding:

The flush control on the toilet in the alternate stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 604

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 484 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the standard stall and the alternate stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

605

Priority:

Restrooms Finding:

The seat cover dispenser in the standard stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 606

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 485 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

607

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom on the Second Floor of the Grandstands Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 608

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 486 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage is not mounted outside of the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

1015

Priority:

Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1016

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 487 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the standard stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Modify or replace the standard stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wallmounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

1017

Priority:

Restrooms Finding:

The door to the alternate stall designated to be accessible in the restroom does not close automatically or have accessible hardware. The inside handle on the standard stall door is not mounted immediately below the latch.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).

Citation

ADAAG A4.17.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

269 269 1018

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 488 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the standard stall door and alternate stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

1019

Priority:

Restrooms Finding:

The height of the side grab bars in the standard stall and the alternate stall designated to be accessible of the restroom is less than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Remount the side grab bars in the standard stall and alternate stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 1020

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 489 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

ADAAG 4.26; CBC 1115B.8.1

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

448

Maximum Estimated Cost:

448

Record Number

1021

Priority:

Restrooms Finding:

The distance from the end of the side grab bars to the back wall in the alternate stall designated to be accessible in the restroom is greater than 12 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Remount the side grab bars in the alternate stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 1022

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 490 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The location of the toilet paper dispenser in the standard stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser in the alternate stall designated to be accessible in the restroom protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Remount the toilet paper dispenser in the standard stall and alternate stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.

Citation

CBC 1115B.9.3; ADAAG 4.16.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1023

Priority:

Restrooms Finding:

The flush control on the toilet in the alternate stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Relocate the flush control on the toilet in the alternate stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.

Citation

ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

127 127 1024

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 491 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the standard stall and alternate stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the standard stall and alternate stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

1025

Priority:

Restrooms Finding:

The seat cover dispenser in the standard stall and alternate stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1026

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 492 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

291

Maximum Estimated Cost:

291

Record Number

1027

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1028

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 493 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of Building 3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 1029

Priority:

Restrooms Finding:

The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

58 58 589

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 494 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.

Citation

CBC 1133B.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 590

Priority:

Restrooms Finding:

The door in the standard stall designated to be accessible in the restroom does not have appropriate accessible hardware.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting.

Citation

CBC 1115B.7.1.3; ADAAG 4.13.9

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

189 189 591

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 495 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the coat hook on the standard stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 592

Priority:

Restrooms Finding:

The height of the side grab bars in the alternate stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

448 448 593

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 496 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The side grab bars in the standard stall and the alternate stall designated to be accessible in the restroom does not extend 54 inches from the back wall.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8.1; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

531

Maximum Estimated Cost: Record Number

531 594

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the standard stall designated to be accessible in the restroom is greater than 18 inches. The distance from the center of the toilet to the nearest side wall in the alternate stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

595

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 497 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

596

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Restroom Outside of the Grandstands (North End) Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 597

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 498 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.

Citation

CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

58

Maximum Estimated Cost:

58

Record Number

798

Priority:

Restrooms Finding:

This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.

Citation

CBC 1115B.7.2; ADAAG 4.16.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 799

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 499 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not have accessible hardware.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.

Citation

CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

4000

Maximum Estimated Cost:

4000

Record Number

800

Priority:

Restrooms Finding:

There are no grab bars in the stall designated to be accessible in the restroom.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.

Citation

CBC 1115B.8; ADAAG 4.26

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

531 531 801

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 500 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).

Citation

ADAAG 4.16.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1707

Maximum Estimated Cost:

1707

Record Number

803

Priority:

Restrooms Finding:

The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.

Citation

CBC 1115B.7.1.3 ADAAG 4.17.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1143

Maximum Estimated Cost:

1143

Record Number

804

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 501 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.

Citation

CBC 1115B.9.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

805

Priority:

Restrooms Finding:

The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.

Citation

ADAAG 4.19.5

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

392 392 806

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 502 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).

Citation

ADAAG 4.19.3

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost:

0

Record Number

807

Priority:

Restrooms Finding:

The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).

Citation

ADAAG 4.19.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

1286

Maximum Estimated Cost:

1286

Record Number

808

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 503 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The pipes under the lavatory in the restroom do not provide protection against contact.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.

Citation

ADAAG 4.19.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

39

Maximum Estimated Cost:

39

Record Number

809

Priority:

Restrooms Finding:

The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.

Citation

ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

291 291 810

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 504 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

811

Priority:

Restrooms Finding:

The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

277 277 812

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 505 of 542

Facility Name: San Joaquin Fairgrounds Restrooms Finding:

The women's restroom provides four private shower stalls. There are no accessible shower stalls provided in the restroom.

Alternative Rec: (Where Available)

*

Women's Showers Next to L-2 and L-3 Full Rec

Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.

Citation

CBC 1115B.6.2; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2853

Maximum Estimated Cost:

2853

Record Number

813

Priority:

Drinking Fountains Finding:

There are 13 drinking fountains on primary paths of travel.

Alternative Rec: (Where Available)

*

Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirement. Fountains not located in alcoves need side rails or wing walls on both sides.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1143

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 506 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height. The drinking fountain does not have accessible fountain controls and requires the use of foot controls to operate.

Alternative Rec: (Where Available)

*

Drinking Fountain at the West Entrance of Building 2 Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost:

2216

Record Number

664

Priority:

Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The water trajectory is diagonal to the front of the unit.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 1 (East Entrance) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The spout shall direct the water flow at least 4 inches high and in a trajectory that is parallel or nearly parallel to the front of the drinking fountain.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1145

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 507 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 1 (North Entrance) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost:

2216

Record Number

1153

Priority:

Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 2 (North Entrance) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1152

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 508 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 2 (South Entrance) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost:

2216

Record Number

1151

Priority:

Drinking Fountains Finding:

The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height. The drinking fountain is not a "high-low" design.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 2 (West Entrance) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1144

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 509 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height. The drinking fountain is not a "high-low" design.

Alternative Rec: (Where Available)

*

Drinking Fountain in Building 6 Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost:

2216

Record Number

1147

Priority:

Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.

Alternative Rec: (Where Available)

*

Drinking Fountain in the Grandstands (East End) Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1150

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 510 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The faucet controls require tight grasping or pinching of the wrist to operate.

Alternative Rec: (Where Available)

*

Drinking Fountain in the Jockey's Quarters Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. Fountain controls shall be accessible.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1146

Priority:

Drinking Fountains Finding:

The drinking fountain is not a "high-low" design.

Alternative Rec: (Where Available)

*

Drinking Fountain Next to the Restrooms in the Winner's Building Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. Provide at least 30 inches in width and 48 inches in depth in front of the drinking fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. The spout shall direct the water flow at least 4 inches high and in a trajectory that is parallel or nearly parallel to the front of the drinking fountain. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

2216 1149

Priority:

Page 511 of 542

Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:

The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.

Alternative Rec: (Where Available)

*

Drinking Fountains Next to the Restrooms in the Grandstands Full Rec

Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.

Citation

CBC 1117B.1; ADAAG 4.15

Minimum Quantity

1

Maximum Quantity:

2

Unit:

Each

Minimum Estimated Cost:

2216

Maximum Estimated Cost: Record Number

4432 1148

Priority:

Commons or Lunch Area Finding:

The height of the tray slides is greater than 34 inches.

Alternative Rec: (Where Available)

*

Building 2 Kitchen Full Rec

Lower the tray slides to a height no greater than 34 inches above the finished floor (see CBC 1104B.5.5 and ADAAG 5.5).

Citation

CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3); ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

30 Linear Feet

Minimum Estimated Cost:

2400

Maximum Estimated Cost:

2400

Record Number

355

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 512 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the concession counter at the north end of the Grandstand is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter at the Grandstand (North End) Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost:

129

Maximum Estimated Cost: Record Number

129 1165

Priority:

Commons or Lunch Area Finding:

The height of the concession counter at the north end of the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter at the Granstands (North End) Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1171

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 513 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the concession counter on the north end of the second level of the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter at the Granstands (North End) Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost:

129

Maximum Estimated Cost: Record Number

129 1172

Priority:

Commons or Lunch Area Finding:

The height of the concession counter at the south end of the second level in the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter in the Grandstands (South End) Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

2

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 258 1175

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 514 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the concession counter outside of Building 2 is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter Outside of Building 2 (South End) Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost:

129

Maximum Estimated Cost:

129

Record Number

1156

Priority:

Commons or Lunch Area Finding:

The height of the concession counter outside of the FFA Office is greater than 36 inches.

Alternative Rec: (Where Available)

*

Concession Counter Outside of the FFA Office Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1166

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 515 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The table top height is greater than 34 inches.

Alternative Rec: (Where Available)

*

Dining Area in the Grandstands Full Rec

Modify or replace one of the tables in the cafeteria to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1174

Priority:

Commons or Lunch Area Finding:

The height of the sales counter in Flats BBQ is greater than 34 inches.

Alternative Rec: (Where Available)

*

Flats BBQ Full Rec

Lower the sales counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).

Citation

CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 342

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 516 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the food service counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Food Service Counter in Building 2 (South End) Full Rec

Lower the food service counter to a height no greater than 34 inches above the finished floor (see CBC 1104B.5.5 and ADAAG 5.5).

Citation

CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3); ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

30 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

2400 2400 1154

Priority:

Commons or Lunch Area Finding:

The height of the north west concession counter at the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 352

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 517 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

There is no level landing provided at the concession counter.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Provide a level and clear landing at least 60 inches in length at the concession counter.

Citation

CBC 1133B.2.4.2; ADAAG 4.13.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 353

Priority:

Commons or Lunch Area Finding:

The height of the south east concession counter in the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 358

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 518 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the north east concession counter in the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost:

129

Maximum Estimated Cost:

129

Record Number

360

Priority:

Commons or Lunch Area Finding:

The height of the bar counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Grandstands (Second Level) Full Rec

Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).

Citation

CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 1173

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 519 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the concession counter in the Linden Lions Building is greater than 36 inches.

Alternative Rec: (Where Available)

*

Linden Lions Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 351

Priority:

Commons or Lunch Area Finding:

The knee space at the tables is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Lyndon Lions Building Full Rec

Modify or replace one of the tables to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1170

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 520 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the concession counter at the Lyndon Lions Club is greater than 36 inches.

Alternative Rec: (Where Available)

*

Lyndon Lions Club Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1164

Priority:

Commons or Lunch Area Finding:

The knee space at the tables in the outdoor dining area at Building 2 is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Outdoor Dining Area Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1155

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 521 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

There is no accessible route to the picnic tables in the outdoor dining area outside of Flat's BBQ. The surface under and around the outdoor dining area picnic tables is dirt, preventing access of individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Outdoor Dining Area Outside of Flats BBQ Full Rec

Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.

Citation

ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

1162

Priority:

Commons or Lunch Area Finding:

The knee space at the tables in the outdoor dining area is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Outdoor Dining Area Outside of Flats BBQ Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1163

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 522 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The knee space at the tables in the outdoor dining area outside of the Champion's Room at the Winner's Gaming and Sports Emporium is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Outdoor Dining Area Outside of the Champion's Room Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

174

Maximum Estimated Cost:

174

Record Number

1167

Priority:

Commons or Lunch Area Finding:

The knee space at the table in the outdoor dining area is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Picnic Table South of the Administration Office Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 1157

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 523 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The picnic tables are nonaccessible by design.

Alternative Rec: (Where Available)

*

Picnic Tables in the Grandstands Full Rec

Modify or replace one of the tables in the Grandstands to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

174

Maximum Estimated Cost:

174

Record Number

1176

Priority:

Commons or Lunch Area Finding:

There is no accessible route to the picnic tables in the outdoor dining area next to L-1.

Alternative Rec: (Where Available)

*

Picnic Tables Next to L-1 Full Rec

Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.

Citation

ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

4' x 60'

Minimum Estimated Cost:

1440

Maximum Estimated Cost:

1440

Record Number

219

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 524 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The tables at the outdoor dining area next to L-1 are nonaccessible by design.

Alternative Rec: (Where Available)

*

Picnic Tables Next to L-1 Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

174 174 220

Priority:

Commons or Lunch Area Finding:

The height of the concession counter at the east end of the Stockton Motorplex is greater than 36 inches.

Alternative Rec: (Where Available)

*

Stockton Motorplex Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 347

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 525 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The height of the bar counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Winners Gaming and Sports Emporium Full Rec

Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).

Citation

CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

348

Maximum Estimated Cost:

348

Record Number

346

Priority:

Commons or Lunch Area Finding:

The height of the bar counter in the Champion's Room at the Winner's Gaming and Sports Emporium is greater than 34 inches.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).

Citation

CBC 1122B.4; ADAAG 4.32.4; ADAAG 5.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 1158

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 526 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

The knee space at the tables in the outdoor dining area is less than 19 inches deep.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

174

Maximum Estimated Cost:

174

Record Number

1159

Priority:

Commons or Lunch Area Finding:

The height of the grill food service counter is greater than 34 inches.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Lower the food service counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).

Citation

CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

348 348 1161

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 527 of 542

Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:

There are no compliant accessible seating areas.

Alternative Rec: (Where Available)

*

Winner's Gaming and Sports Emporium Full Rec

Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.

Citation

CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

237

Maximum Estimated Cost:

237

Record Number

1169

Priority:

Assembly Areas Finding:

There is no compliant wheelchair seating at the Speedway bleachers.

Alternative Rec: (Where Available)

*

Delta Speedway Full Rec

Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.

Disability Access Consultants, Inc.

(800) 743-7067

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1180

Priority:

Page 528 of 542

Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:

The width of the benches in each locker room is less then 24 inches. The length of the benches in each locker room is less then 48 inches. The height of the benches in each locker room is greater than 19 inches.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

Install at least one bench with dimensions of 24 inches in width by 48 inches in length fixed to the wall along the longer dimension in each locker room. Mount the bench 17 inches to 19 inches above the finished floor with ADAAG 4.35.4 in each locker room. Provide sufficient clear floor space alongside the bench to allow a person using a wheelchair to make a parallel transfer onto the bench.

Citation

ADAAG 4.35.4

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

500

Maximum Estimated Cost:

500

Record Number

1198

Priority:

Locker Rooms Finding:

The height of the coat hooks in the locker room is greater than 54 inches above the floor surface.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

Remount the coat hooks to a maximum height of 54 inches above the floor surface.

Citation

CBC 1115B.9.2; ADAAG A4.27

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1199

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 529 of 542

Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:

Showers are provided, there are no accessible showers in the Jockey's Quarters.

Alternative Rec: (Where Available)

*

Jockey's Quarters Full Rec

Since open showers are provided in the locker room, at least one accessible shower is required. Install an accessible shower in one of the corners with L-shaped grab bars extending along the two walls with a folding seat adjacent to the shower controls in the locker room (see CBC 1115B.6.3 and ADAAG 4.21).

Citation

CBC 1115B.6.3; ADAAG 4.21

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

3260

Maximum Estimated Cost:

3260

Record Number

1204

Priority:

Locker Rooms Finding:

This sauna is not accessible and cannot be easily altered. There is not sufficient clear floor space in the sauna to accommodate an individual in a wheelchair.

Alternative Rec: (Where Available)

*

Sauna in the Jockey's Quarters Full Rec

Consult a design professional to modify the sauna. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the sauna to accommodate an individual in a wheelchair.

Citation

CBC 1115B.7.2; ADAAG 4.16.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1203

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 530 of 542

Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:

The soap dish is mounted at a height greater than 40 inches above the shower floor.

Alternative Rec: (Where Available)

*

Women's Restroom at Horse Barn 3 Full Rec

Relocate the soap dish mounted in the shower compartment designated to be accessible in the restroom so that it is mounted on the same wall as the water controls at a maximum height of 40 inches above the shower floor (see CBC 1115B.6.2.4.6).

Citation

CBC 1115B.6.2.4.6

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

277

Maximum Estimated Cost:

277

Record Number

1202

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

Bleachers Between L-2 and L-3 Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1187

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 531 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

Bleachers Next to L-1 Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1194

Priority:

Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

Bleachers Next to L-1 Full Rec

Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

107 107 1195

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 532 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

Bleachers South of L-5 Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1192

Priority:

Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter at L-5 indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

Bleachers South of L-5 Full Rec

Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

107 107 1193

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 533 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter at the Delta Speedway or the Grandstands indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

Delta Speedway Full Rec

Post signage at each ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

107 107 1179

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The height of the concession counter at the east end of the Delta Speedway is greater than 36 inches.

Alternative Rec: (Where Available)

*

Delta Speedway Full Rec

Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1181

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 534 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

The height of the ticket counter at the west end of the Delta Speedway is greater than 36 inches. The counter is a protruding object.

Alternative Rec: (Where Available)

*

Delta Speedway Full Rec

Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1182

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The press box above the stadium is stair-access only and is not accessible to individuals with mobility impairments.

Alternative Rec: (Where Available)

There are ways to provide access to the programs, services and activities at the press box without installing accessible vertical means to the press box area, to include electronic relay devices with electronic visual components (video camera or television) that offer the equivalent sight line provided from inside the press box. The electronic relays may be cabled to an accessible location where individuals with mobility impairments can access.

Full Rec

In most instances, press boxes are built and used by volunteers and the public, which mandates that access for individuals with disabilities be provided. This is difficult in most situations with the location of the press box usually located high above the assembly area. Vertical access may include installing an exterior enclosed platform lift or installing an equivalent press box at ground level with electronic relay devices and equipment that would provide the same line of sight viewing capability as that in the elevated press box.

Delta Speedway Citation Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1208

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 535 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

The height of the ticket counter at the entrance to the Grandstands is greater than 36 inches.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1184

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The press box above the stadium is stair-access only and is not accessible to individuals with mobility impairments.

Alternative Rec: (Where Available)

There are ways to provide access to the programs, services and activities at the press box without installing accessible vertical means to the press box area, to include electronic relay devices with electronic visual components (video camera or television) that offer the equivalent sight line provided from inside the press box. The electronic relays may be cabled to an accessible location where individuals with mobility impairments can access.

Full Rec

In most instances, press boxes are built and used by volunteers and the public, which mandates that access for individuals with disabilities be provided. This is difficult in most situations with the location of the press box usually located high above the assembly area. Vertical access may include installing an exterior enclosed platform lift or installing an equivalent press box at ground level with electronic relay devices and equipment that would provide the same line of sight viewing capability as that in the elevated press box.

Grandstands Citation Minimum Quantity

1

Maximum Quantity:

1

Unit:

Custom

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1196

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 536 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

There is no compliant accessable seating areas at the Grandstand Bleachers.

Alternative Rec: (Where Available)

*

Grandstands Full Rec

Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

237

Maximum Estimated Cost:

237

Record Number

1197

Priority:

Outdoor Sports Areas and Playgrounds Finding:

There is stair access only to the bleachers. The surface under the bleachers is concrete. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

L-1 Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1188

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 537 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter at L-1 indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

L-1 Full Rec

Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost:

107

Maximum Estimated Cost:

107

Record Number

1189

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The surface under the bleachers is concrete. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

L-3 Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1185

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 538 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter at L-3 indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

L-3 Full Rec

Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

107 107 1186

Priority:

Outdoor Sports Areas and Playgrounds Finding:

The grass surface of the soccer field at the facility prevents access to individuals with mobility impairments.

Alternative Rec: (Where Available)

*

Soccer Field Full Rec

Provide an accessible route to the soccer field area where programs, services and activities are provided. The minimum width of the path of travel is 48 inches with 60 inch by 60 inch passing spaces provided every 200 feet. No protruding objects are permitted on the accessible path of travel. Accessible surfaces shall be firm, stable and slip resistant.

Citation

CBC 1104B.1.2; CBC 1124B.1; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

30 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

360 360 1205

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 539 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

There is stair access only to the bleachers. The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.

Alternative Rec: (Where Available)

*

Stockton Motorplex Full Rec

Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.

Citation

CBC 1104B.4; ADAAG 4.33

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

237 237 1190

Priority:

Outdoor Sports Areas and Playgrounds Finding:

There is no signage at the ticket counter at the Stockton Motorplex indicating the availability of accessible seating.

Alternative Rec: (Where Available)

*

Stockton Motorplex Full Rec

Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).

Citation

CBC 1104B.3.4.1; ADAAG 4.1.3(19)

Minimum Quantity

1

Maximum Quantity:

1

Unit:

Each

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

107 107 1191

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 540 of 542

Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:

The height of the ticket counter next to Buildings 2 and 3 is greater than 36 inches.

Alternative Rec: (Where Available)

*

Ticket Counter Next to Buildings 2 and 3 Full Rec

Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).

Citation

ADAAG 7.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

3 Linear Feet

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

129 129 1183

Priority:

Emergency Warning Systems Finding:

The facility shall have a fire and life safety emergency plan that specifically addresses the evacuation of individuals with disabilities.

Alternative Rec: (Where Available)

*

Full Rec

A fire and life safety emergency plan that specifically addresses the evacuation of individuals with disabilities must comply with CFC Part 9 and CBC 1114B.2 for areas of rescue assistance.

Citation

CFC Part 9 & CBC 1114B.2

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost:

0

Maximum Estimated Cost: Record Number

0 1206

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 541 of 542

Facility Name: San Joaquin Fairgrounds Emergency Warning Systems Finding:

There are visual warning devices in the Winners Gaming and Sports Emporium, though no visual warning devices are located elsewhere in the facility.

Alternative Rec: (Where Available)

Altering a facility's programs, or addressing higher priority barriers can reduce or eliminate the need for an area of rescue assistance, such as making certain that an individual with a disability participates in programs located near an already accessible exit. Otherwise creating an accessible exit can provide an acceptable alternative to providing an area of rescue assistance.

Full Rec

Install visual warning devices integrated with the facility's alarm system complying with CBC 1114B.2.5, ADAAG 4.1.3(14) and ADAAG 4.28 throughout the facility.

Citation

CBC 1114B.2.4; ADAAG 4.1.3(14); ADAAG 4.28

Minimum Quantity

1

Maximum Quantity:

1

Unit:

None Selected

Minimum Estimated Cost: Maximum Estimated Cost: Record Number

0 288 1207

Priority:

Disability Access Consultants, Inc.

(800) 743-7067

Page 542 of 542