Accessibility Survey Americans with Disabilities Act And Title 24 of the California Building Code
San Joaquin County Fairgrounds Prepared By Disability Access Consultants, Inc. (800) 743-7067
WORKING DRAFT 1658 S. Airport Way Stockton, CA
Facility Name: San Joaquin Fairgrounds Programs, Services, and Activities Finding:
The San Joaquin Fairgrounds, located at 1658 South Airport Way in Stockton California, was inspected by Disability Access Consultants, Inc., on May 8 and 9, 2006.
Alternative Rec: (Where Available)
*
Full Rec
Any renovation or new construction that occurred after January 26, 1992, is subject to meet full code specifications for the California Building Code and ADAAG requirements. All recommendations in this report are based on ADAAG and CBC title 24 requirements. Consult with your design professional to determine which elements are affected by these requirements. It is recommended that Disability Access Consultants, Inc. is consulted for inspection of any new construction or renovation at the facility.
Citation
ADAAG 4.1.2; ADAAG 4.1.3; ADAAG 4.1.5; ADAAG 4.1.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number Priority:
0 103
Parking Finding:
There are seven parking lots provided at the facility. The paved parking lots are located outside of the main entrance gate, outside of the Winners Gaming and Sports Emporium, outside of Buildings 1, 2, 4 and 6 thru 8, outside of Flates BBQ, next to the Horse Barns, next to the soccer field and outside of the Maintenance Shop.
Alternative Rec: (Where Available)
*
Full Rec
Accessible paved parking spaces shall be located on the shortest accessible route of travel to the facility and shall coincide with the primary route and primary entrances used by the general public (see CBC 1129B.4, ADAAG 4.3.2(1) and ADAAG 4.14.1).
Citation
CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.14.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 104
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 1 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
Parking is provided off-street to the public and/or employees outside of Buildings 1, 2, 4 and 6 thru 8, though no marked spaces are provided.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec
Stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6. Accessible parking spaces shall be located on the shortest accessible route of travel to the facility for which it serves and shall coincide with the primary route and entrances used by the general public (see CBC 1129B and ADAAG 4.3.2(1). The access aisle and route to the primary facility entrance shall also be of an accessible surface.
Citation
CBC 1129B; ADAAG 4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
113
Priority:
Parking Finding:
Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec
Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The van-accessible parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 114
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 2 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8 Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
150
Maximum Estimated Cost:
150
Record Number
115
Priority:
Parking Finding:
Paved parking is provided outside of Flats BBQ. There are no accessible parking spaces designated out of 17 total parking spaces provided in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Flats BBQ Full Rec
One out of the 17 total number of marked parking spaces is required to be designated exclusively for accessible parking, as required by CBC 1129B and ADAAG. Create one vanaccessible parking space measuring at least 108 inches wide and 216 inches long with an access aisle measuring at least 96 inches wide (8 feet) located on the passenger side (right side) of the parking space (see CBC 1129B). Add the words NO PARKING in 12 inch high white letters at the entrance to the accessible parking access aisle.
Citation
CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.6.2; ADAAG 4.1.2(5)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
270 270 116
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 3 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
The designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Flats BBQ Full Rec
Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from the accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
150
Maximum Estimated Cost:
150
Record Number
117
Priority:
Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of Flats BBQ Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 118
Priority:
Page 4 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
Alternative Rec: (Where Available)
There are 14 accessible parking spaces provided. Each accessible parking space provided measures at least 108 inches wide and 216 inches long. The two van-accessible parking spaces each provide an access aisle, located on the passenger side of the parking space, measuring 96 inches wide. Two of the standard accessible parking spaces provide an adjacent access aisle measuring 95 inches wide. There is no access aisle provided adjacent to ten of the standard accessible parking spaces. The access aisles do not contain "NO PARKING" in 12" high white letters *
Parking Lot Outside of the Main Entrance Gate Full Rec
Fourteen parking spaces meets the number required to be designated exclusively for accessible parking according to ADAAG and CBC 1129B. Restripe the designated accessible parking spaces to create two van-accessible and 12 standard accessible parking space, each measuring at least 108 inches wide and 216 inches long. The van-accessible spaces shall provide an access aisle measuring at least 96 inches wide (8 feet) on the passenger side (right side) of the vehicle space (see CBC 1129B). The additional parking spaces shall each provide an access aisle measuring at least 60 inches wide, that may be shared. Add the words NO PARKING in 12 inch high white letters at the entrance to each accessible parking access aisle.
Citation
CBC 1129B; ADAAG 4.6; ADAAG A4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
270
Maximum Estimated Cost:
270
Record Number
106
Priority:
Parking Finding:
There is no crosswalk provided on the path of travel from the accessible parking spaces to the facility. The required accessible route crosses a vehicular way.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Main Entrance Gate Full Rec
Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.
Citation
ADAAG 4.7.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
100 100 107
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 5 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
There is no vertically-mounted signage at the designated accessible parking spaces in the parking lot showing the International Symbol of Accessibility. There is no additional signage marked "van-accessible" at the van-accessible parking spaces.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Main Entrance Gate Full Rec
Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
150
Maximum Estimated Cost:
150
Record Number
108
Priority:
Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Main Entrance Gate Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 109
Priority:
Page 6 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
Parking is provided off-street to the public and/or employees outside of the Maintenance Shop, though the parking lot surface is gravel and nonaccessible.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Maintenance Shop Full Rec
Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.
Citation
CBC 1129B; ADAAG 4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
125
Priority:
Parking Finding:
There is signage designating one nonaccessible parking space as accessible. The designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Maintenance Shop Full Rec
Remove the signage designating the nonaccessible parking space as accessible. Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from the accessible parking space (see CBC 1129B.5). The bottom edge of the sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The van-accessible parking space shall provide an additional sign marked "vanaccessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 126
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 7 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Maintenance Shop Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 127
Priority:
Parking Finding:
There are 12 accessible parking spaces out of 344 parking spaces which is sufficient in number as required for compliance.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec
Twelve out of the 344 total number of marked parking spaces meets the number required to be designated exclusively for accessible parking according to ADAAG and CBC 1129B.
Citation
CBC 1129B; ADAAG 4.6; ADAAG A4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 110
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 8 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
Alternative Rec: (Where Available)
Parking Continued: Two of the accessible parking spaces measure less than 108 inches wide and at least 216 inches long. Ten of the accessible parking spaces measure at least 108 inches wide and 216 inches long. The van-accessible parking space provides an access aisle, located on the passenger side of the vehicle space, measuring at least 96 inches wide. Each standard accessible parking space provides an adjacent access aisle measuring 60 inches wide. The access aisles do not contain "NO PARKING" in 12" high white letters *
Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec
Restripe the designated accessible parking spaces to create one van-accessible and one standard accessible parking space, each measuring at least 108 inches wide and 216 inches long with an access aisle measuring at least 96 inches wide (8 feet) shared between the two accessible parking spaces (see CBC 1129B). The accessible parking space with the access aisle to the right of the space shall be designated "van-accessible." Add the words NO PARKING in 12 inch high white letters at the entrance to each accessible parking access aisle.
Citation
CBC 1129B; ADAAG 4.6; ADAAG A4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
270 270 111
Priority:
Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
Parking Lot Outside of the Winners Gaming and Sports Emporium Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 112
Priority:
Page 9 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
Parking is provided off-street to the public next to the Horse Barns, though the parking lot surface is gravel and nonaccessible. The parking lot can provide approximately 40 parking spaces.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Horse Barns Full Rec
Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.
Citation
CBC 1129B; ADAAG 4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
119
Priority:
Parking Finding:
Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Horse Barns Full Rec
Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "van-accessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 120
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 10 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Horse Barns Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
150
Maximum Estimated Cost:
150
Record Number
121
Priority:
Parking Finding:
Parking is provided off-street to the public next to the soccer field, though the parking lot surface is gravel and nonaccessible. The parking lot can provide approximately 66 parking spaces.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Soccer Field Full Rec
Pave the parking lot and stripe parking spaces with an appropriate number of accessible parking spaces designated to comply with CBC 1129B and ADAAG 4.6.
Citation
CBC 1129B; ADAAG 4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 122
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 11 of 542
Facility Name: San Joaquin Fairgrounds Parking Finding:
There is signage designating two of the nonaccessible parking spaces as accessible. Each designated accessible parking space required in the parking lot shall provide a post-mounted sign showing the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Soccer Field Full Rec
Remove the signage designating the nonaccessible parking spaces. Install a permanently posted reflectorized sign measuring 70 square inches that includes an ISA symbol adjacent to and visible from each accessible parking space (see CBC 1129B.5). The bottom edge of each sign must be mounted 80 inches from the ground surface so that it cannot be obscured by a parked vehicle (see CBC 1129B.5). The "vanaccessible" parking space shall provide an additional sign marked "van-accessible" mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4).
Citation
CBC 1129B.5; ADAAG 4.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
150
Maximum Estimated Cost:
150
Record Number
123
Priority:
Parking Finding:
There is no warning signage posted at the entrance to the parking lot regarding unauthorized use of accessible parking spaces in the parking lot.
Alternative Rec: (Where Available)
*
RV Parking Lot Next to the Soccer Field Full Rec
Post a sign in a conspicuous place to the entrance of the parking lot, or immediately adjacent to and visible from each accessible parking space. The warning sign shall measure at least 17 inches by 22 inches in size and consist of lettering at least 1 inch in height that clearly and conspicuously states the following; "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at ____ or by telephoning ___ ." Fill in the blank spaces with appropriate information as a permanent part of the sign and maintain the currency of the information (see CBC 1129B.5).
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
150 150 124
Priority:
Page 12 of 542
Facility Name: San Joaquin Fairgrounds Passenger Loading Zones Finding:
There is no required striped access aisle adjacent to the passenger loading zone. There is no signage designating accessibility posted at the passenger loading zone.
Alternative Rec: (Where Available)
*
Passenger Loading Zone Outside of the Winners Emporium Full Rec
Stripe an access aisle at least 5 feet (60 inches) wide and 20 feet (240 inches) long adjacent and parallel to the vehicle pull-up space. The access aisle striping for the passenger loading zone shall provide immediate access to the adjacent curb ramp. Post signage designating the passenger loading zone as accessible (see CBC 1131B and ADAAG 4.1.2(7)(b)). The sign should contain the International Symbol of Accessibility.
Citation
CBC 1131B; ADAAG 4.6.6; ADAAG 4.1.2(7)(b)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
300 300 128
Priority:
Curb Ramps Finding:
The slope of the top landing is greater than 2%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.
Alternative Rec: (Where Available)
*
Curb Ramp at the Winners Gaming and Sports Emporium Main Entrance Full Rec
Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).
Citation
CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1033
Maximum Estimated Cost:
1033
Record Number
131
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 13 of 542
Facility Name: San Joaquin Fairgrounds Curb Ramps Finding:
The built-up curb ramp projects into vehicular traffic and interferes with individuals entering or exiting parked or standing vehicles. The slope of the curb ramp is greater than 8.33%. The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.
Alternative Rec: (Where Available)
*
Curb Ramp Outside of Flats BBQ Full Rec
Remove the asphalt built-up curb ramp and install a compliant curb-cut ramp that provides a slope no greater than 8.33% and complies with CBC 1127B; ADAAG 4.7. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).
Citation
CBC 1127B; ADAAG 4.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1400
Maximum Estimated Cost:
1400
Record Number
129
Priority:
Curb Ramps Finding:
The slope of each side of the concrete sidewalk curb ramp is greater than 8.33%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.
Alternative Rec: (Where Available)
*
Curb Ramp Outside of the Winners Gaming and Sports Emporium Full Rec
Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).
Citation
CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1033
Maximum Estimated Cost:
1033
Record Number
134
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 14 of 542
Facility Name: San Joaquin Fairgrounds Curb Ramps Finding:
The slope of the curb ramp is greater than 8.33%. The slope of the side flares is greater than 10%. The curb ramp does not provide a grooved border along the top and sides of the ramp at the level of the sidewalk. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.
Alternative Rec: (Where Available)
*
Curb Ramp to the Women's Showers Full Rec
Replace the curb ramp with a compliant curb ramp at least 48 inches in width that provides a slope no greater than 8.33%. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).
Citation
CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1033
Maximum Estimated Cost:
1033
Record Number
133
Priority:
Curb Ramps Finding:
The built-up curb ramps provided at the accessible parking spaces outside of the Winners Gaming and Sports Emporium project into an access aisle and interfere with individuals entering or exiting parked or standing vehicles. The slope of the side flares is greater than 10%. The concrete curb ramp does not provide a detectable warning surface which includes truncated domes.
Alternative Rec: (Where Available)
*
Curb Ramps at the Accessible Parking Spaces Full Rec
Remove each built-up curb ramp and install a compliant curbcut ramp that provides a slope no greater than 8.33% and complies with CBC 1127B; ADAAG 4.7. Install a detectable warning surface which extends the full length and width of the concrete curb ramp and its side flares with truncated domes that contrast visually by either light on dark or dark on light which is an integral part of the concrete curb ramp. The truncated domes may be cast in place or stamped or of a prefabricated surface treatment (see CBC 1127B.5.8).
Citation
CBC 1127B; ADAAG 4.7
Minimum Quantity
1
Maximum Quantity:
7
Unit:
Each
Minimum Estimated Cost:
1400
Maximum Estimated Cost:
9800
Record Number
132
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 15 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is no accessible route from the public right of way off of B Street to the accessible entrance of the facility. The accessible route crosses vehicular traffic.
Alternative Rec: (Where Available)
Post directional signage.
Accessible Route from the Public Right of Way Full Rec
Provide at least one accessible route from the public right of way to the accessible entrance of the facility. Make certain to post signage indicating the direction to accessible building entrances at every major junction along the accessible route. Signs shall include the International Symbol of Accessibility.
Citation
CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3; ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
107
Maximum Estimated Cost:
0
Record Number
202
Priority:
Path of Travel Finding:
There is no crosswalk provided on the path of travel from the public right of way off of B Street to Flats BBQ. The required accessible route crosses a vehicular way.
Alternative Rec: (Where Available)
*
Accessible Route from the Public Right of Way Full Rec
Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance of the facility. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.
Citation
ADAAG 4.7.9 ADAAG 4.2.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
100 100 203
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 16 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is no accessible route from the public right of way off of South 8th Street to the accessible entrance of the facility. The accessible route crosses vehicular traffic.
Alternative Rec: (Where Available)
Post directional signage.
Accessible Route from the Public Right of Way Full Rec
Provide at least one accessible route from the public right of way to the accessible entrance of the facility. Make certain to post signage indicating the direction to accessible building entrances at every major junction along the accessible route. Signs shall include the International Symbol of Accessibility.
Citation
CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3; ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
107
Maximum Estimated Cost:
0
Record Number
221
Priority:
Path of Travel Finding:
There is no crosswalk provided on the path of travel from the public right of way off of South 8th Street to the facility. The required accessible route crosses a vehicular way.
Alternative Rec: (Where Available)
*
Accessible Route from the Public Right of Way Full Rec
Stripe a crosswalk not less than 48 inches wide on the path of travel to the accessible entrance of the facility. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Detectable warnings should be placed at the entrance and exit of the crosswalk.
Citation
ADAAG 4.7.9 ADAAG 4.2.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
100 100 222
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 17 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are only stairs to the primary functions provided on the stage in Building 2, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Building 2 Full Rec
Install a vertical platform lift to provide a direct path between the stage and level seating area in Building 2, allowing individuals with mobility impairments to participate in programs, services and activities provided by the facility on the stage. The ADA mandates accessibility to programs, services and activities which serve the public.
Citation
CBC 1114B.1.2; ADAAG 4.3.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
0 8210 189
Priority:
Path of Travel Finding:
The width of the gate next to the reception counter in Building 7 is less than 32 inches making the area nonaccessible to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
Modify or replace the gate, to provide at least 32 inches in width (see CBC 1133B.1.1.1.4; ADAAG 4.13.3). Make certain the gate provides level and clear landings on each side of the gate and that each landing provides the minimum maneuvering clearances required. The gate shall provide accessible hardware.
Citation
CBC 1133B.1.1.1.4; CBC 1133B.1.1.1.1; ADAAG 4.13.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 137
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 18 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The mat does not adhere to the underlying floor surface and creates a hazardous path of travel.
Alternative Rec: (Where Available)
*
Building 7 Main Entrance Full Rec
Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.
Citation
CBC 1124B.3; ADAAG 4.5.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
659
Maximum Estimated Cost:
659
Record Number
136
Priority:
Path of Travel Finding:
There is grating outside of Building 6 with elongated openings greater than 1/2 inch running the along the direction of travel.
Alternative Rec: (Where Available)
*
Drainage Grate Full Rec
Replace the grating with a grating that provides openings equal to or less than 1/2 inch wide. If the grating has elongated openings, the grating shall be set where the elongated openings are perpendicular to the dominant direction of travel (see CBC 1133B.7.2 and ADAAG 4.5.4).
Citation
CBC 1133B.7.2; ADAAG 4.5.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
588 588 148
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 19 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
Lockers are a service provided for public use in the exercise room at the Stable Office. The lockers have hardware which requires tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Lockers Full Rec
When an individual with a disability has need for the locker service, modify a locker as needed or provide equivalent facilitation upon request.
Citation
CBC 1105.4.3; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
159
Priority:
Path of Travel Finding:
The mat at the south entrance to the Main Building does not adhere to the underlying floor surface and creates a hazardous path of travel.
Alternative Rec: (Where Available)
*
Main Building (South Entrance) Full Rec
Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.
Citation
CBC 1124B.3; ADAAG 4.5.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
659 659 166
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 20 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are open tree wells along the path of travel in Building 6 with a change in elevation greater than 1/2 inch, creating a tripping hazard.
Alternative Rec: (Where Available) Open Tree Wells Full Rec
Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Citation
ADAAG 4.3.8; CBC 1133B.7.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
70
Maximum Estimated Cost:
70
Record Number
149
Priority:
Path of Travel Finding:
There are open tree wells along the path of travel next to L-4 and L-5 with a change in elevation greater than 1/2 inch, creating a tripping hazard.
Alternative Rec: (Where Available) Open Tree Wells Full Rec
Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Citation
ADAAG 4.3.8; CBC 1133B.7.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
70 70 152
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 21 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are open tree wells along the path of travel south of L-5 with a change in elevation greater than 1/2 inch, creating a tripping hazard.
Alternative Rec: (Where Available) Open Tree Wells Full Rec
Install edge protection on each side of the open tree well consisting of 3-inch high guide curb above the surface of the path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Citation
ADAAG 4.3.8; CBC 1133B.7.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
70
Maximum Estimated Cost:
70
Record Number
213
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel between Buildings 5 and 6.
Alternative Rec: (Where Available)
*
Path of Travel Between Buildings 5 and 6 Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
175
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 22 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is a change in elevation greater than 1/2 inch on the primary path of travel between L-4 and L-5.
Alternative Rec: (Where Available)
*
Path of Travel Between L-4 and L-5 Full Rec
Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).
Citation
CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
212
Priority:
Path of Travel Finding:
The walkway serves as a primary path of travel. The width of the bridge is less than 48 inches in width. There are slopes greater than 8.33% on the primary path of travel on the walkway.
Alternative Rec: (Where Available)
*
Path of Travel in Building 6 Full Rec
Modify the exterior primary path of travel by extending the width of the walkway to at least 48 inches (see CBC 1118B.2 and ADAAG 4.3.3). Since the accessible route is less than 60 inches in width, provide passing spaces at least 60 inches by 60 inches at reasonable intervals every 200 feet. Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1; CBC 1133B.2.3; CBC 1118B.2; ADAAG 4.1.3(16); ADAAG 4.3.3; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 197
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 23 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The width of the interior path of travel behind the counter in L-1 is less than 36 inches.
Alternative Rec: (Where Available)
*
Path of Travel in L-1 Full Rec
Modify the interior path of travel to provide at least 36 inches in width. If the interior path of travel includes 180-degree turn around an object, the clear width shall be at least 42 inches (see CBC 1118B.1, CBC 1118B.3 and ADAAG 4.3.3).
Citation
CBC 1118B.1; CBC 1118B.3; ADAAG 4.3.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 141
Priority:
Path of Travel Finding:
The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.
Alternative Rec: (Where Available)
*
Path of Travel in L-1 Full Rec
Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).
Citation
CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
200
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 24 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public. There are cross slopes greater than 2% on the primary path of travel.
Alternative Rec: (Where Available)
*
Path of Travel in L-4 Full Rec
Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5). Provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
211
Priority:
Path of Travel Finding:
There is a change in elevation greater than 1/2 inch on the primary path of travel.
Alternative Rec: (Where Available)
*
Path of Travel in the FFA Office Full Rec
Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).
Citation
CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
172
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 25 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel at the west end of the Linden Lions Building.
Alternative Rec: (Where Available)
*
Path of Travel in the West End of the Linden Lions Building Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
153
Priority:
Path of Travel Finding:
The typical paths of travel throughout Building 6 is gravel, preventing access to individuals with mobility impairments. The width of typical walkways is less than 48 inches in width.
Alternative Rec: (Where Available)
*
Path of Travel Throughout Building 6 Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
198
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 26 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.
Alternative Rec: (Where Available)
*
Path of Travel Throughout L-2 Full Rec
Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).
Citation
CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
169
Priority:
Path of Travel Finding:
The surface of the primary accessible path of travel is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.
Alternative Rec: (Where Available)
*
Path of Travel Throughout L-3 Full Rec
Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).
Citation
CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
170
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 27 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The path of travel from the parking lot to Building 4 is gravel, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to Building 4 Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
151
Priority:
Path of Travel Finding:
The surface of the primary accessible path of travel from Building 6 to Building 5 is rough and uneven, providing a hazardous surface for individuals with mobility impairments and the general public.
Alternative Rec: (Where Available)
*
Path of Travel to Building 5 Full Rec
Resurface the path of travel to provide a smooth, firm, stable and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and ADAAG 4.5).
Citation
CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
196
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 28 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The path of travel to the north entrance of Building 5 is grass, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to Building 5 (North Entrance) Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
215
Priority:
Path of Travel Finding:
The path of travel to the south entrance to Building 6 is grass, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to Building 6 (South Entrance) Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
214
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 29 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is a step on the primary path of travel to Building 8, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to Building 8 Full Rec
Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.
Citation
CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
9515
Maximum Estimated Cost:
9515
Record Number
135
Priority:
Path of Travel Finding:
The path of travel is to L-6 grass, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to L-6 Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
143
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 30 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The path of travel to the annex next to the Jockey's Quarters is dirt, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Annex Next to the Jockey's Quarters Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
259
Priority:
Path of Travel Finding:
There are only stairs to the primary functions provided, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Annex Next to the Jockey's Quarters Full Rec
Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.
Citation
CBC 1133B.5; ADAAG 4.3.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
9515
Maximum Estimated Cost:
9515
Record Number
260
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 31 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the bleachers at the Delta Speedway.
Alternative Rec: (Where Available)
*
Path of Travel to the Bleachers at the Delta Speedway Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
178
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel between the men's and women's restroom at the Grandstand.
Alternative Rec: (Where Available)
*
Path of Travel to the Bleachers at the Grandstand Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
145
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 32 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is a change in elevation greater than 1/2 inch on the primary path of travel.
Alternative Rec: (Where Available)
*
Path of Travel to the Building 5 Main Entrance Full Rec
Bevel the area or resurface the area to provide a smooth and level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and ADAAG 4.5.2).
Citation
CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
150
Priority:
Path of Travel Finding:
There are slopes greater than 8.33% on the primary path of travel on the walkway to the concession stand at the south east end of the Grandstand.
Alternative Rec: (Where Available)
*
Path of Travel to the Concession Stand Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Otherwise, install a ramp that does not exceed a slope greater than 8.33% and complies with CBC 1133B.5 and ADAAG 4.8.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
144
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 33 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the concession stand at the Delta Speedway.
Alternative Rec: (Where Available)
*
Path of Travel to the Concession Stand at the Delta Speedway Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
177
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel from the restrooms to the concession stand at the Delta Speedway.
Alternative Rec: (Where Available)
*
Path of Travel to the Concession Stand at the Delta Speedway Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
179
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 34 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 8.33% on the primary path of travel on the walkway from Charter Way to the Delta Speedway.
Alternative Rec: (Where Available)
*
Path of Travel to the Delta Speedway Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%. Otherwise, install a ramp that does not exceed a slope greater than 8.33% and complies with CBC 1133B.5 and ADAAG 4.8.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
201
Priority:
Path of Travel Finding:
There is a step on the primary path of travel to the First Aid Room in the Maintenance Building, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the First Aid Room Full Rec
Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.
Citation
CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
9515
Maximum Estimated Cost:
9515
Record Number
193
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 35 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The path of travel to Horse Barns A thru U, excluding Horse Barn S, is dirt, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Horse Barns Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
176
Priority:
Path of Travel Finding:
The path of travel from the Stable Office to the Horse Barns is a combination of dirt, gravel and asphalt, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Horse Barns Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
204
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 36 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The path of travel to the north entrance of the Jockey's Quarters is dirt, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Jockey's Quarters (North Entrance) Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
205
Priority:
Path of Travel Finding:
The path of travel to the Linden Lions Building is grass, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Linden Lions Building Full Rec
Install an accessible route to where programs, services and activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2). The minimum width of the path of travel shall be 48 inches with a firm, stable and slip-resistant surface. No protruding objects are permitted on the accessible path of travel and slopes shall not exceed 5% in the direction of travel.
Citation
CBC 1114B.1.2; ADAAG 4.3.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
154
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 37 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the men's restroom next to Horse Barn N.
Alternative Rec: (Where Available)
*
Path of Travel to the Men's Restroom Next to Horse Barn N Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
130
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the men's restroom next to Horse Barn Q.
Alternative Rec: (Where Available)
*
Path of Travel to the Men's Restroom Next to Horse Barn Q Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
305
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 38 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5%, due to an asphalt build-up, on the primary path of travel to the men's showers next to the Livestock Office.
Alternative Rec: (Where Available)
*
Path of Travel to the Men's Showers Next to the Livestock Office Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
713
Priority:
Path of Travel Finding:
There is a step on the primary path of travel to the milk parlor, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Milk Parlor Full Rec
Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.
Citation
CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
9515
Maximum Estimated Cost:
9515
Record Number
199
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 39 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the press box at the Delta Speedway.
Alternative Rec: (Where Available)
*
Path of Travel to the Pressbox at the Delta Speedway Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
1440 1440 1178
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the second level of the Grandstands.
Alternative Rec: (Where Available)
*
Path of Travel to the Second Level of the Grandstands Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
147
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 40 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are only stairs to the primary functions provided, preventing access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Path of Travel to the Stockton Motorplex Office Full Rec
Since programs, services and activities to staff and the public (volunteers, etc.) are provided in this location, those programs, services and activities are required to be made accessible. It is recommended that a ramp be installed or other means of vertical access.
Citation
CBC 1133B.5; ADAAG 4.3.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
9515
Maximum Estimated Cost:
9515
Record Number
164
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the women's restroom at the Grandstand.
Alternative Rec: (Where Available)
*
Path of Travel to the Women's Restroom at the Grandstand Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
167
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 41 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There are slopes greater than 5%, due to an asphalt build-up, on the primary path of travel to the women's restroom at the soccer field.
Alternative Rec: (Where Available)
*
Path of Travel to the Women's Restroom at the Soccer Field Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
896
Priority:
Path of Travel Finding:
There are slopes greater than 5% on the primary path of travel to the women's restroom next to horse barn 4.
Alternative Rec: (Where Available)
*
Path of Travel to the Women's Restroom Next to Horse Barn 4 Full Rec
Resurface the path of travel to provide a level surface that does not exceed a slope greater than 5%. Cross slopes shall not exceed 2%.
Citation
CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
467
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 42 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
There is no accessible route to the picnic tables in the outdoor dining area east of Building 6.
Alternative Rec: (Where Available)
*
Picnic Tables East of Building 6 Full Rec
Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.
Citation
ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
194
Priority:
Path of Travel Finding:
The knee space at the tables in the outdoor dining area is less than 27 inches high.
Alternative Rec: (Where Available)
*
Picnic Tables East of Building 6 Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 195
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 43 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The leading edge of the wall-mounted storage compartments in the Jockey's Quarters is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Object Full Rec
Install side extensions, modify, relocate, or lower the storage compartments so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).
Citation
CBC 1121B.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost:
640
Maximum Estimated Cost:
640
Record Number
157
Priority:
Path of Travel Finding:
The leading edge of the wall-mounted box outside of the Livestock Office is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Object Full Rec
Install side extensions, modify, relocate, or lower the box so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).
Citation
CBC 1121B.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 640 171
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 44 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The leading edge of the fire extinguisher at the north end of the Grandstands, Building 6, at the north entrance to Building 3, the east entrance to Building 5, in the Stable Office, the break room in the Administration Building and in Building 4 is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Object Full Rec
Consult with the local fire marshal to determine the feasibility of moving the fire extinguishers to new locations (such as in a corner) to eliminate the protrusion into the primary path of travel. Otherwise, install side extensions or wing walls on each fire extinguisher throughout the facility so that the leading edges are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).
Citation
CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
173
Priority:
Path of Travel Finding:
The leading edge of the wall-mounted counter in the Grandstands is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Object Full Rec
Install side extensions, modify, relocate, or lower the counter so that the leading edge protrudes less than 4 inches from the wall, or are less than 27 inches from the floor (see CBC 1121B.1 and ADAAG 4.4).
Citation
CBC 1121B.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 640 1177
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 45 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The beams throughout the Grandstand protrude into the primary path of travel by providing a hazardous height range greater than 27 inches and less than 80 inches from the floor.
Alternative Rec: (Where Available)
*
Protruding Objects Full Rec
Install side extensions or other permanent devices that extend lower than 27 inches from the floor surface to prevent it from protruding into the primary path of travel.
Citation
CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 640 146
Priority:
Path of Travel Finding:
The leading edge of each display case in the Winners Gaming and Sports Emporium is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Objects Full Rec
Install side extensions or wing walls on each display case so that its leading edge is less than 27 inches from the floor.
Citation
CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
4
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 2560 165
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 46 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The leading edge of the electrical outlets in L-2 and L-3 is more than 4 inches from the wall and less than 80 inches above the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Objects Full Rec
Modify or relocate the electrical outlets so that the leading edge protrudes less than 4 inches from the wall and is at least 80 inches above the floor (see CBC 1121B.1 and ADAAG 4.4).
Citation
CBC 1121B.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 640 168
Priority:
Path of Travel Finding:
The leading edge of the display cases in Building 6 is more than 4 inches from the wall and greater than 27 inches from the floor and protrudes into the primary path of travel.
Alternative Rec: (Where Available)
*
Protruding Objects Full Rec
Install side extensions or wing walls on the display case so that its leading edge is less than 27 inches from the floor.
Citation
CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
640 640 218
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 47 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The sink in Building 7 is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in Building 7 Full Rec
Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
420 420 138
Priority:
Path of Travel Finding:
The pipes under the sink in Building 7 do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in Building 7 Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 139
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 48 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The faucet controls on the sink in Building 7 require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Sink in Building 7 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in Building 7. Lever-operated, pushtype, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 140
Priority:
Path of Travel Finding:
The sink in Building 8 is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in Building 8 Full Rec
Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
420 420 185
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 49 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The pipes under the sink in Building 8 do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in Building 8 Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 186
Priority:
Path of Travel Finding:
The faucet controls on the sink in Building 8 require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Sink in Building 8 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in Building 8. Lever-operated, pushtype, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 187
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 50 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The sink in the Administration Office is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in the Administration Office Full Rec
Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
420
Maximum Estimated Cost:
420
Record Number
182
Priority:
Path of Travel Finding:
The pipes under the sink in the Administration Building do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in the Administration Office Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 183
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 51 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The sink in the Jockey's Quarters is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in the Jockeys Quarters Full Rec
Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
420
Maximum Estimated Cost:
420
Record Number
155
Priority:
Path of Travel Finding:
The pipes under the sink in the Jockey's Quarters do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in the Jockeys Quarters Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 156
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 52 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The knee clearance space under the sink designated to be accessible in the Jockey's Quarters is less than 27 inches.
Alternative Rec: (Where Available)
*
Sink in the Jockey's Quarters Full Rec
Raise or replace the sink designated to be accessible in the restroom to provide at least 27 inches of clear knee space and a minimum of nine inches clear toe space.
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
206
Priority:
Path of Travel Finding:
The faucet controls on the sink in the Jockey's Quarters require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Sink in the Jockey's Quarters Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Jockey's Quarters. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 207
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 53 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The height of the counter surface of the sink designated to be accessible in the Linden Lions Building is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in the Linden Lion's Building Full Rec
Relocate the sink designated to be accessible in the room to provide a maximum counter surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
208
Priority:
Path of Travel Finding:
The pipes under the sink in the Linden Lion's Building do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in the Linden Lion's Building Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 209
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 54 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The faucet controls on the sink in the Linden Lion's Building require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Sink in the Linden Lion's Building Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Linden Lion's Building. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
210
Priority:
Path of Travel Finding:
The knee clearance space under the sink designated to be accessible in the Maintenance Building is less than 27 inches.
Alternative Rec: (Where Available)
*
Sink in the Maintenance Building (East End) Full Rec
Raise or replace the sink designated to be accessible to provide at least 27 inches of clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
161
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 55 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The height of the counter surface of the sink designated to be accessible in the Maintenance Building is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in the Maintenance Building (East End) Full Rec
Relocate the sink designated to be accessible in the room to provide a maximum counter surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
162
Priority:
Path of Travel Finding:
The faucet controls on the sink in the Maintenance Building require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Sink in the Maintenance Building (East End) Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the sink designated to be accessible in the Maintenance Building. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 163
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 56 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The sink in the Maintenance Office is in an enclosed cabinet, thereby preventing an accessible forward approach. The height of the counter surface is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Sink in the Maintenance Office Full Rec
Sinks in rooms must provide clear floor space in front of the sink for an accessible forward approach and shall provide at least 27 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the sink cabinet and replace with an accessible wall-mounted sink unit.
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
420
Maximum Estimated Cost:
420
Record Number
191
Priority:
Path of Travel Finding:
The pipes under the sink in the Maintenance Office do not provide protection against contact.
Alternative Rec: (Where Available)
*
Sink in the Maintenance Office Full Rec
Insulate or otherwise configure pipes under the sink designated to be accessible in the room to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the sink.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 192
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 57 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The mat at the east entrance to the Stable Office does not adhere to the underlying floor surface and creates a hazardous path of travel.
Alternative Rec: (Where Available)
*
Stable Office (East Entrance) Full Rec
Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.
Citation
CBC 1124B.3; ADAAG 4.5.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
659
Maximum Estimated Cost:
659
Record Number
160
Priority:
Path of Travel Finding:
The mat at the entrance to the Stable Office does not adhere to the underlying floor surface and creates a hazardous path of travel.
Alternative Rec: (Where Available)
*
Stable Office Main Entrance Full Rec
Securely fasten the mats or replace with a mat that grips to the underlying floor surface to provide a firm, stable, continuous and relatively smooth path of travel surface (see CBC 1124B.3 and ADAAG 4.5.3). Mats along the primary path of travel shall provide beveled edges on all sides to prevent roll over.
Citation
CBC 1124B.3; ADAAG 4.5.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
659 659 158
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 58 of 542
Facility Name: San Joaquin Fairgrounds Path of Travel Finding:
The knee space at the tables in the gambling area is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Modify or replace one of the tables in the gambling area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
174
Maximum Estimated Cost:
174
Record Number
1160
Priority:
Path of Travel Finding:
The knee space at the tables in the Champion's Section is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Modify or replace one of the tables in the Champion's Section to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1168
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 59 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The slope of the ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to Building 7 Full Rec
Modify the run of the ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
225
Priority:
Ramps Finding:
The width of the run of the ramp is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to Building 7 Full Rec
Widen the run of the ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).
Citation
CBC 1133B.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
7500
Maximum Estimated Cost:
7500
Record Number
226
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 60 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
There is only one handrail provided on the ramp. There are no 12-inch extensions beyond the top and bottom of the ramp.
Alternative Rec: (Where Available)
*
Exterior Ramp to Building 7 Full Rec
Install a handrail on each side of the ramp that provide a continuous and smooth gripping surface diameter between 1 1/4 inches to 1 7/8 inches, mounted at a height between 34 inches and 38 inches and shall be at a distance no less than 1 1/2 inches from the adjacent wall. The ends of the handrail shall extend 12 inches in a parallel height from the top and bottom of the ramp and return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1200
Maximum Estimated Cost:
1200
Record Number
227
Priority:
Ramps Finding:
The slope of the concrete ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Grandstands Full Rec
Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
223
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 61 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The ends of the handrails end abruptly.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Grandstands Full Rec
Replace the handrails on each side of the ramp that return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
1320
Maximum Estimated Cost:
1320
Record Number
224
Priority:
Ramps Finding:
The slope of the bottom run of the metal ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec
Modify the bottom run of the metal ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
238
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 62 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The width of the run of each run of the metal ramp is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec
Widen each run of the metal ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).
Citation
CBC 1133B.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
7500
Maximum Estimated Cost:
7500
Record Number
239
Priority:
Ramps Finding:
The ramp changes direction more than 30 degrees. The length of the intermediate turn landing on the ramp is less than 72 inches. The width of the intermediate landing is less than 60 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec
Modify or replace the intermediate turn landing on the ramp to provide at least 72 inches in length in the direction of the run of the ramp and 60 inches in width (see CBC 1133B.5.4.6 and ADAAG 4.8.4).
Citation
CBC 1133B.5.4; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
0 1872 240
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 63 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The handrails are mounted at a height less than 34 inches. There are no 12-inch extensions beyond the top and bottom right of the ramp. The gripping surface of the handrails are interrupted by posts.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (East End) Full Rec
Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
1320
Maximum Estimated Cost:
1320
Record Number
241
Priority:
Ramps Finding:
The slope of the bottom run of the metal ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec
Modify the bottom run of the metal ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
242
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 64 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The width of the run of the metal ramp is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec
Widen the run of the metal ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).
Citation
CBC 1133B.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
7500
Maximum Estimated Cost:
7500
Record Number
243
Priority:
Ramps Finding:
The ramp changes direction more than 30 degrees. The length of the intermediate turn landing on the ramp is less than 72 inches. The width of the intermediate landing is less than 60 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec
Modify or replace the intermediate turn landing on the ramp to provide at least 72 inches in length in the direction of the run of the ramp and 60 inches in width (see CBC 1133B.5.4.6 and ADAAG 4.8.4).
Citation
CBC 1133B.5.4; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
0 1872 244
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 65 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The handrails are mounted at a height less than 34 inches. There are no 12-inch extensions beyond the top and bottom right of the ramp. The gripping surface of the handrails are interrupted by posts.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Bleachers at the Speedway (West End) Full Rec
Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
1320
Maximum Estimated Cost:
1320
Record Number
245
Priority:
Ramps Finding:
The slope of the concrete ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Milk Parlor Full Rec
Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
235
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 66 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
There is no top landing on the ramp.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Milk Parlor Full Rec
Modify or replace the ramp so that it has a top landing complying with CBC 1133B.4.1 and ADAAG 4.8.4.
Citation
CBC 1133B.4.1; ADAAG 4.8.4(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost:
1872
Record Number
236
Priority:
Ramps Finding:
The handrails are mounted at a height greater than 38 inches. There are no 12-inch extensions beyond the top right and bottom of the ramp. The gripping surface of the right handrail is interrupted by a post.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Milk Parlor Full Rec
Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The gripping surface shall be smooth and free from interruptions. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
1320
Maximum Estimated Cost:
1320
Record Number
237
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 67 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The slope of the concrete ramp is greater than 8.33%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec
Modify the run of the concrete ramp to provide a slope no greater than 8.33% with a cross slope not exceeding 2% (see CBC 1133B.5.3 and ADAAG 4.8.2).
Citation
CBC 1133B.5.3; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
4920
Maximum Estimated Cost:
4920
Record Number
228
Priority:
Ramps Finding:
The distance between the latch side of the door on a side approach from the top landing is less than 42 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec
Modify or replace the top landing on the ramp to provide at least 42 inches distance between the latch side of the door and the side of the landing to accommodate the required side approach to the entrance door (see CBC 1133B.5.4.2 and ADAAG 4.8.4(2)).
Citation
CBC 1133B.4.2; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
48 Square Feet
Minimum Estimated Cost:
1872
Maximum Estimated Cost:
1872
Record Number
229
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 68 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
There are no 12-inch extensions beyond the top right and bottom of the ramp. The ends of the right handrail end abruptly.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (East Side) Full Rec
Weld pipe extensions on the handrails of the ramp so that they continue 12 inches beyond the end of the ramp parallel to the ground surface and return smoothly to the post or wall (see CBC 1133B.5.5 and ADAAG 4.8.5).
Citation
CBC 1133B.5.5; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
2400
Maximum Estimated Cost:
2400
Record Number
230
Priority:
Ramps Finding:
The width of the run of the wood ramp is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec
Widen the run of the wood ramp so that it has a minimum clear width of 48 inches (see CBC 1133B.5.2.2).
Citation
CBC 1133B.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
8383
Maximum Estimated Cost:
8383
Record Number
231
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 69 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The length of the top landing on the ramp is less than 60 inches.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec
Modify or replace the top landing on the ramp to provide a top landing that exceeds 60 inches in length (see CBC 1133B.5.4.2 and ADAAG 4.8.4(2)).
Citation
CBC 1133B.4.2; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
48 Square Feet
Minimum Estimated Cost:
1872
Maximum Estimated Cost:
1872
Record Number
232
Priority:
Ramps Finding:
The slope of the bottom landing is greater than 2%.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec
Resurface the bottom landing of the ramp to provide a level surface not exceeding a slope greater than 2% (see CBC 1133B.5.4.5).
Citation
CBC 1133B.4.5; ADAAG 4.8
Minimum Quantity
1
Maximum Quantity:
1
Unit:
48 Square Feet
Minimum Estimated Cost:
1872
Maximum Estimated Cost:
1872
Record Number
233
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 70 of 542
Facility Name: San Joaquin Fairgrounds Ramps Finding:
The handrails are mounted at a height less than 34 inches. The 12-inch extensions beyond the bottom of the ramp are not parallel to the ground surface.
Alternative Rec: (Where Available)
*
Exterior Ramp to the Restrooms at the Speedway (West Side) Full Rec
Replace the handrails on each side of the ramp to provide a height between 34 inches and 38 inches. The handrails shall provide 12-inch extensions, extending beyond the top and bottom of the ramp, that are parallel to the ground surface and return smoothly to the post or wall.
Citation
CBC 1133B.5.5; ADAAG 4.8.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
60 Linear Feet
Minimum Estimated Cost:
1320
Maximum Estimated Cost:
1320
Record Number
234
Priority:
Platform Lifts Finding:
There is a platform lift at the Grandstands. The platform lift provides accessible vertical path of travel to the bleachers. The platform lift is capable of providing independent operation.
Alternative Rec: (Where Available)
*
Platform Lift at the Grandstands Full Rec
Platform lifts must be capable of independent operation. Platform lifts shall not modified in any manner or serve as an accessible means of egress. Platform lifts shall comply with CBC 1105.3, CBC 1104.1.4, ADAAG 4.11 and ASME A17.1 Safety Code for Elevators and Escalators, Section XX, 1990.
Citation
CBC 1105.3; CBC 1104.1.4; ADAAG 4.11
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 246
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 71 of 542
Facility Name: San Joaquin Fairgrounds Platform Lifts Finding:
There is no level landing provided at the entrance to the platform lift.
Alternative Rec: (Where Available)
*
Platform Lift at the Grandstands Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
247
Priority:
Stairs Finding:
There is no detectable striping on each tread of the exterior stairway.
Alternative Rec: (Where Available)
*
Exterior Stairs to Building 7 Full Rec
Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.
Citation
CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
144 144 255
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 72 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
The width of the exterior stairway is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Stairs to Building 7 Full Rec
Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).
Citation
CBC 1006.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4672
Maximum Estimated Cost:
4672
Record Number
256
Priority:
Stairs Finding:
There is only one handrail on the stairway. The handrail does not provide 12-inch extensions beyond the top treads.
Alternative Rec: (Where Available)
*
Exterior Stairs to Building 7 Full Rec
Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.
Citation
CBC 1133B.4.2; ADAAG 4.9.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
24 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
528 528 257
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 73 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
The top riser on the stairway is open.
Alternative Rec: (Where Available)
*
Exterior Stairs to Building 7 Full Rec
Close the riser openings on the stairway (see CBC 1006.16.3 and ADAAG 4.9.2). Open risers are not permitted.
Citation
CBC 1133B.4.5.3; ADAAG 4.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
480 480 258
Priority:
Stairs Finding:
There is no detectable striping on each tread of the exterior stairway.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec
Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.
Citation
CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
144 144 261
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 74 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
The width of the exterior stairway is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec
Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).
Citation
CBC 1006.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4672
Maximum Estimated Cost:
4672
Record Number
262
Priority:
Stairs Finding:
The handrails do not provide 12-inch extensions beyond the top and bottom treads. The diameter of the gripping surface is greater than 1 7/8 inches. The handrails are mounted at a height less than 34 inches.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Annex Next to the Jockey's Quarters Full Rec
Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.
Citation
CBC 1133B.4.2; ADAAG 4.9.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
24 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
528 528 263
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 75 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
Detectable striping is provided on the top two and bottom two treads only.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Grandstands Full Rec
Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.
Citation
CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
Minimum Quantity
1
Maximum Quantity:
6
Unit:
Each
Minimum Estimated Cost:
144
Maximum Estimated Cost:
864
Record Number
252
Priority:
Stairs Finding:
The handrails do not provide 12-inch extensions beyond the top and bottom treads.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Grandstands Full Rec
Install handrails on each side of stairway that provide 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall.
Citation
CBC 1133B.4.2; ADAAG 4.9.4
Minimum Quantity
1
Maximum Quantity:
6
Unit:
24 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
528 3168 253
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 76 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
Two of the exterior stairways do not provide handrails on each side of the bottom run of the stairway.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Grandstands Full Rec
Install handrails on each side of stairway that provide a gripping surface between 1 1/4 to 1 7/8 inches with 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.
Citation
CBC 1133B.4.2; ADAAG 4.9.4
Minimum Quantity
1
Maximum Quantity:
2
Unit:
24 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost:
528 1056
Record Number
254
Priority:
Stairs Finding:
There is no detectable striping on each tread of the exterior stairway.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Office at the Stockton Motorplex Full Rec
Affix detectable contrasting striping to each tread of the stairway that clearly contrasts in color from the tread and is at least 2 inches in width placed no more than 1 inch from the tread nose or landing.
Citation
CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
144 144 248
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 77 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
The width of the exterior stairway is less than 48 inches.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Office at the Stockton Motorplex Full Rec
Install an exterior stairway with a minimum width of 48 inches (see CBC 1006.2).
Citation
CBC 1006.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4672
Maximum Estimated Cost:
4672
Record Number
249
Priority:
Stairs Finding:
The handrails do not provide 12-inch extensions beyond the bottom treads. The handrails are mounted at a height greater than 38 inches.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Office at the Stockton Motorplex Full Rec
Install handrails on each side of stairway that provide 12-inch top and bottom handrail extensions that extend beyond the top and bottom treads of the stairway which are parallel to the ground surface and return smoothly to the post or wall. Handrails shall be mounted at a height between 34 and 38 inches at a distance no less than 1 1/2 inches from the adjacent wall.
Citation
CBC 1133B.4.2; ADAAG 4.9.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
24 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
528 528 250
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 78 of 542
Facility Name: San Joaquin Fairgrounds Stairs Finding:
The risers on the stairway are open.
Alternative Rec: (Where Available)
*
Exterior Stairs to the Office at the Stockton Motorplex Full Rec
Close the riser openings on the stairway (see CBC 1006.16.3 and ADAAG 4.9.2). Open risers are not permitted.
Citation
CBC 1133B.4.5.3; ADAAG 4.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
480 480 251
Priority:
Doors Finding:
The bottom 10 inches of the door from the lobby to the east wing does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Administration Office Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 264
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 79 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
There is less than 12 inches of latch side clearance from the push side of the entrance door to the office at the south east end of the Administration Office.
Alternative Rec: (Where Available)
*
Administration Office Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
265
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 1 (East Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 268
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 80 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 1 (East Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
269
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 1 (North Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 266
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 81 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 1 (North Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
267
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 1 (South Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 332
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 82 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 1 (South Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
333
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 1 (West Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 270
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 83 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 1 (West Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 271
Priority:
Doors Finding:
The interior passage door next to the restrooms in Building 2 has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Building 2 Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 285
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 84 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door to the restrooms in Building 2 does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 2 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
286
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 2 (North Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 336
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 85 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stops.
Alternative Rec: (Where Available)
*
Building 2 (North Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
337
Priority:
Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 2 (South Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 338
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 86 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 3 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 324
Priority:
Doors Finding:
The bottom 10 inches of the exterior doors at Building 4 do not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 4 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 298
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 87 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the exterior doors at Building 5 do not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 5 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 295
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 6 Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 292
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 88 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Building 6 (East Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 327
Priority:
Doors Finding:
Exterior passage doors have round doorknobs, which require twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
834 834 279
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 89 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 280
Priority:
Doors Finding:
The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Building 8 Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
834 834 272
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 90 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Building 8 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 273
Priority:
Doors Finding:
There is less than 12 inches of clearance on the latch side of the exterior entrance door.
Alternative Rec: (Where Available)
*
Building 8 Full Rec
Provide at least 12 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 276
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 91 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The landing at the entrance door does not provide sufficient clear floor space.
Alternative Rec: (Where Available)
*
Door at L-1 Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
142
Priority:
Doors Finding:
The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Exterior Door to the Gym at the Stable Office Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
834 834 314
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 92 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Exterior Door to the North West Office Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 331
Priority:
Doors Finding:
The height of the threshold at the entrance door is greater than 1/2 inch.
Alternative Rec: (Where Available)
*
FFA Office Full Rec
Modify or replace the threshold to provide a smooth transition. The threshold should not exceed a beveled 1/2 inch. Provide a 60 inch level landing in the direction of the door swing.
Citation
CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2500
Maximum Estimated Cost:
2500
Record Number
290
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 93 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
There is less than 24 inches of clearance on the latch side of the exterior entrance door.
Alternative Rec: (Where Available)
*
Flats BBQ Full Rec
Provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 319
Priority:
Doors Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 322
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 94 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
323
Priority:
Doors Finding:
The interior passage door to the employee restroom has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Interior Door at the South End of the Grandstands Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 291
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 95 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Interior Door in Building 8 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 277
Priority:
Doors Finding:
The interior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Interior Door in Building 8 Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 278
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 96 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The interior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Interior Door in L-1 Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
287
Priority:
Doors Finding:
There is less than 18 inches of latch side clearance from the pull side of the interior entrance door from the restrooms to the east wing.
Alternative Rec: (Where Available)
*
Interior Door in the Stable Office Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door from the pull side (see ADAAG 4.13.6 and Figure 25).
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 318
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 97 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Interior Door to the Gym in the Stable Office Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
312
Priority:
Doors Finding:
There is less than 18 inches of latch side clearance from the pull side of the interior entrance door.
Alternative Rec: (Where Available)
*
Interior Door to the Gym in the Stable Office Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door from the pull side (see ADAAG 4.13.6 and Figure 25).
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 313
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 98 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The interior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Interior Door to the Laundry Room in the Jockey's Quarters Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 328
Priority:
Doors Finding:
The bottom 10 inches of the interior doors in the Jockey's Quarters does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 299
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 99 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The exterior door is set in an alcove. There is less than 24 inches of clearance on the latch side of the exterior entrance door.
Alternative Rec: (Where Available)
Install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.
Jockey's Quarters Full Rec
Povide at least 24 inches between the latch side of the door and the side wall of the alcove at the primary entrance. Otherwise install a compliant automatic door opening device.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1921
Maximum Estimated Cost:
0
Record Number
329
Priority:
Doors Finding:
The exterior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Jockey's Quarters (North Entrance) Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
834 834 300
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 100 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
There is less than 24 inches of clearance on the latch side of the exterior entrance door.
Alternative Rec: (Where Available)
*
Jockey's Quarters (North Entrance) Full Rec
Provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 303
Priority:
Doors Finding:
The interior passage door has a round doorknob, which requires twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Livestock Office Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 288
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 101 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Livestock Office Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
289
Priority:
Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Main Office (South Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 321
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 102 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
Interior passage doors have round doorknobs, which require twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Maintenance Office Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 330
Priority:
Doors Finding:
Exterior passage doors at each entrance to the Stable Office have round doorknobs, which require twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
834 834 306
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 103 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 307
Priority:
Doors Finding:
The height of the threshold at the entrance door is greater than 1/2 inch.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Modify or replace the threshold to provide a smooth transition. The threshold should not exceed a beveled 1/2 inch. Provide a 60 inch level landing in the direction of the door swing.
Citation
CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2500
Maximum Estimated Cost:
2500
Record Number
310
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 104 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
Interior passage doors have round doorknobs, which require twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Interior door hardware (doorknobs) should be changed to accessible lever-handled lockset hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
311
Priority:
Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Stable Office (East Entrance) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 317
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 105 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
Exterior passage doors have round doorknobs, which require twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Stable Office (West Entrance) Full Rec
Replace the existing door hardware with accessible hardware (see ADAAG 4.13.9).
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
834
Maximum Estimated Cost:
834
Record Number
315
Priority:
Doors Finding:
The landing at the entrance door does not provide sufficient clear floor space.
Alternative Rec: (Where Available)
*
Stable Office (West Entrance) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 316
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 106 of 542
Facility Name: San Joaquin Fairgrounds Doors Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Winners Gaming and Sports Emporium Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
320
Priority:
Counters Finding:
The height of the Administration Office reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Administration Office Full Rec
Lower at least a 36 inch wide portion of the Administration Office reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 339
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 107 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the Building 3 reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Building 3 Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
343
Priority:
Counters Finding:
The height of the Building 7 reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 357
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 108 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the counter at the scale shop is greater than 34 inches.
Alternative Rec: (Where Available)
*
Delta Speedway Full Rec
Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
341
Priority:
Counters Finding:
The height of the Fitness Center reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Fitness Center (West Entrance) Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 361
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 109 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the Fitness Center reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Fitness Center in the Stable Office Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
349
Priority:
Counters Finding:
The height of the betting counter at the south end of the Grandstands is greater than 34 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 359
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 110 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the betting counters is greater than 34 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower at least a 36 inch wide portion of the counters to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
362
Priority:
Counters Finding:
The height of the reception counter in L-1 is greater than 34 inches.
Alternative Rec: (Where Available)
*
L-1 Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 354
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 111 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the exterior counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Livestock Office Full Rec
Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
344
Priority:
Counters Finding:
The height of the Security Office reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Security Office Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 356
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 112 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the reception counter at the east entrance to the Stable Office is greater than 34 inches.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Lower at least a 36 inch wide portion of the sales counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
348
Priority:
Counters Finding:
The height of the Stable Office reception counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Lower at least a 36 inch wide portion of the reception counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 350
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 113 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the ticket counters at the main entrance to the Fairgrounds is greater than 36 inches.
Alternative Rec: (Where Available)
*
Ticket Counters at the Main Entrance Full Rec
Lower one of the ticket counters to a height no greater than 36 inches above the ground (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost:
129
Maximum Estimated Cost:
129
Record Number
190
Priority:
Counters Finding:
The height of the change counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Winners Gaming and Sports Emporium Full Rec
Lower at least a 36 inch wide portion of the change counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 340
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 114 of 542
Facility Name: San Joaquin Fairgrounds Counters Finding:
The height of the Champions counters is greater than 34 inches.
Alternative Rec: (Where Available)
*
Winners Gaming and Sports Emporium Full Rec
Lower at least a 36 inch wide portion of the counter to a maximum height between 28 and 34 inches (see CBC 1122B.4).
Citation
CBC 1122B.4; ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 345
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Administration Office Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 366
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 115 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Administration Office Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 367
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 1 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 334
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 116 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 1 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 335
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 2 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 283
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 117 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 2 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 284
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 3 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 325
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 118 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 3 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 326
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 4 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 370
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 119 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 4 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 371
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 5 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 216
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 120 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 5 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 217
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 6 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 293
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 121 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 6 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 294
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 281
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 122 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 7 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 282
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Building 8 Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 274
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 123 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Building 8 Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
275
Priority:
Visual and Audible Communications Finding:
There is no directional signage to the accessible entrance from the public right of way or other common use areas.
Alternative Rec: (Where Available)
*
Directional Signage Full Rec
Install directional signage to each common area complying with CBC 1117B.5 and ADAAG 4.30.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 379
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 124 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
FFA Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
368
Priority:
Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
FFA Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 369
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 125 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Flats BBQ Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
374
Priority:
Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Flats BBQ Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 375
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 126 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
301
Priority:
Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 302
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 127 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Linden Lions Building Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
372
Priority:
Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Linden Lions Building Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 373
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 128 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Main Office Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
376
Priority:
Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Main Office Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 377
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 129 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There are four pay telephones at the facility, located in the Winners Gaming and Sports Emporium, outside of the men's restroom next to the Livestock area, next to the Stable Office and at the west entrance of Building 2.
Alternative Rec: (Where Available)
*
Pay Telephone Full Rec
Contact the telephone company that owns the pay telephone regarding following items that do not comply with ADA requirements. The telephone company is responsible for ADA compliance, if the facility has no ownership in the pay telephone.
Citation
CBC 1117B.2.1; ADAAG 4.31
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
363
Priority:
Visual and Audible Communications Finding:
There is no electrical outlet within or adjacent to the telephone enclosure.
Alternative Rec: (Where Available)
*
Pay Telephone at the West Entrance to Building 2 Full Rec
Electrical outlets within or adjacent to the telephone enclosure are required at pay telephones designed to accommodate a portable text telephone.
Citation
CBC 1117B.2.9; ADAAG 4.31
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 365
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 130 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
There is no electrical outlet within or adjacent to the telephone enclosure.
Alternative Rec: (Where Available)
*
Pay Telephone Outside of the Men's Restroom at the Livestock Area Full Rec
Electrical outlets within or adjacent to the telephone enclosure are required at pay telephones designed to accommodate a portable text telephone.
Citation
CBC 1117B.2.9; ADAAG 4.31
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
364
Priority:
Visual and Audible Communications Finding:
There is no directional signage to the accessible restrooms outside of Building 1.
Alternative Rec: (Where Available)
*
Restrooms Outside of Building 1 Full Rec
Install directional signage to the accessible restrooms outside of Building 1 complying with CBC 1117B.5 and ADAAG 4.30.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 188
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 131 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
Rooms do not have accessible signage mounted on the wall adjacent to the latch side of the doors.
Alternative Rec: (Where Available)
*
Room Signage Full Rec
Install accessible signage identifying each room on the wall adjacent to the latch side of the doorway centered at 60 inches above the finished floor. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door. Signs shall include raised UPPERCASE letters/numbers between 5/8 inch and 2 inches in height and Grade 2 Braille characters. Color and finish shall comply with CBC 1117B.5 and ADAAG 4.30.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 378
Priority:
Visual and Audible Communications Finding:
The contact device in the Winners Gaming and Sports Emporium does not have accessible signage mounted on the wall adjacent to the device.
Alternative Rec: (Where Available)
*
Service Bell in the Winners Gaming and Sports Emporium Full Rec
Install compliant informational signage on the wall adjacent to the contact device complying with CBC 1117B.5 and ADAAG 4.30.5.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 180
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 132 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The height of the service bell is greater than 48 inches above the floor for an accessible forward approach reach height.
Alternative Rec: (Where Available)
*
Service Bell in the Winners Gaming and Sports Emporium Full Rec
Lower the service bell to provide an accessible forward approach reach height no greater than 48 inches above the finished floor.
Citation
CBC 1118B.5; ADAAG 4.2.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 181
Priority:
Visual and Audible Communications Finding:
There is no signage with the International Symbol of Accessibility on the entrance door to the facility designating it as accessible.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
The International Symbol of Accessibility shall be the standard used to identify facilities that are accessible to and usable by physically disabled persons (see CBC 1117B.5.1). All building entrances that are accessible to and usable by persons with disabilities shall be identified with an ISA symbol (see CBC 1117B.5.7).
Citation
CBC 1117B.5.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 308
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 133 of 542
Facility Name: San Joaquin Fairgrounds Visual and Audible Communications Finding:
The main entrance does not have accessible signage mounted on the wall adjacent to the latch side of the door.
Alternative Rec: (Where Available)
*
Stable Office Full Rec
Install signage centered at 60 inches above the finished floor on the wall adjacent to the latch side of the entry doorway stating ENTRANCE from the outside and EXIT from the inside, with raised UPPERCASE letters between 5/8 inch and 2 inches in height and Grade 2 Braille characters. The sign shall comply with the finish and contrast requirements set forth in CBC 1117B.5 and ADAAG 4.30.5. Signage should be located where a person may approach within three inches of the sign without encountering protruding objects or standing within the swing of the door.
Citation
CBC 1117B.5; ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
309
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 624
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 134 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
625
Priority:
Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
626
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 135 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
627
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
628
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 136 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
629
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 630
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 137 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
631
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
632
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 138 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
633
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 634
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 139 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
635
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
636
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 140 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
637
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 638
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 141 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
639
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 640
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 142 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 852
Priority:
Restrooms Finding:
The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 853
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 143 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bar in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
854
Priority:
Restrooms Finding:
The location of the toilet paper dispenser in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Remount the toilet paper dispenser in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 855
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 144 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
856
Priority:
Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 857
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 145 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.
Citation
CBC 1115B.9.4; ADAAG 4.18.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 858
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
859
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 146 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
860
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Faculty Unisex Restroom at the Grandstands (South End) Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 861
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 147 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
773
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 774
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 148 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
775
Priority:
Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 776
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 149 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are six stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
777
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
778
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 150 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
779
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 780
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 151 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
781
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 783
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 152 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
784
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
785
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 153 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
786
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 787
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 154 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
788
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 2 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 789
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 155 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
520
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 521
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 156 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 12 inches of latch side clearance from the push side of the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
522
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 523
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 157 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
524
Priority:
Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 525
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 158 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
526
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 527
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 159 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
528
Priority:
Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 529
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 160 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
530
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is nonaccessible and requires the use of foot controls to operate.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 531
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 161 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
532
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 533
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 162 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
534
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
535
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 163 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
536
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 537
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 164 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
538
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 4 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 539
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 165 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
961
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 962
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 166 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
963
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 964
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 167 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor. The flush control valve on the urinal is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
965
Priority:
Restrooms Finding:
There is less than 30 inches by 48 inches of clear floor space provided in front of the urinal in the restroom to allow an accessible forward approach.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
The minimum clear floor space in front of the urinal designated to be accessible in the restroom shall be at least 30 inches by 48 inches to provide an accessible forward approach (see CBC 1115B.9.4 and ADAAG 4.18.3). Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the urinal.
Citation
CBC 1115B.9.4; ADAAG 4.18.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 966
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 168 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The latch side approach to the stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
967
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
968
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 169 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
969
Priority:
Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 970
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 170 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
971
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
973
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 171 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no clear floor space provided in front of the seat cover dispenser.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
974
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 975
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 172 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Building 5 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
976
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 431
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 173 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The door opening force for the interior entrance door to the restroom is greater than 5 pounds.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Adjust the closer on the interior entrance door to the restroom to a maximum door opening force of 5 pounds (see CBC 1133B.2.5.1 and ADAAG 4.13.11).
Citation
CBC 1133B.2.5.1; ADAAG 4.13.11
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
5
Maximum Estimated Cost:
5
Record Number
432
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
433
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 174 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
434
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 435
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 175 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
436
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
437
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 176 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no clear floor space provided in front of the seat cover dispenser.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
438
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
439
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 177 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Flats BBQ Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
440
Priority:
Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 559
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 178 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
560
Priority:
Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 561
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 179 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
562
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 563
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 180 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
564
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
565
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 181 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
566
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 567
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 182 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
568
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 569
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 183 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
570
Priority:
Restrooms Finding:
There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn 2 Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
571
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 184 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
1043
Priority:
Restrooms Finding:
The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
1024 1024 1044
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 185 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1045
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1046
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 186 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
1047
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost: Record Number
1707 1049
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 187 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1050
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1051
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 188 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
1052
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 1053
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 189 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
1054
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1055
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 190 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1056
Priority:
Restrooms Finding:
The men's restroom provides two private shower stalls. There are no accessible shower stalls provided in the men's restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the men's restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost: Record Number
2853 1057
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 191 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
1058
Priority:
Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the showers from the pull side.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn N Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1059
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 192 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
1060
Priority:
Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 1061
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 193 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1062
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1063
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 194 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
1064
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost: Record Number
1707 1066
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 195 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1067
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1068
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 196 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
1069
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 1070
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 197 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1071
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1072
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 198 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The women's restroom provides two private shower stalls. There are no accessible shower stalls provided in the women's restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the women's restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
1101
Priority:
Restrooms Finding:
The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1102
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 199 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the showers in the restroom from the pull side.
Alternative Rec: (Where Available)
*
Men's Restroom at Horse Barn Q Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
1103
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 687
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 200 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
688
Priority:
Restrooms Finding:
The door opening force for the exterior door is greater than 5 pounds of force.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).
Citation
CBC 1133B.2.5; ADAAG 4.13.11
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
5
Maximum Estimated Cost: Record Number
5 689
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 201 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
690
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 691
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 202 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
692
Priority:
Restrooms Finding:
The distance from the end of the side grab bars to the back wall in the stall designated to be accessible in the restroom is greater than 12 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 693
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 203 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
694
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
695
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 204 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
696
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 697
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 205 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
698
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at Livestock Building 1 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 699
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 206 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage indicating accessibility on the latch side of the entry door of the restroom does not include Braille or raised lettering and is not centered at 60 inches above the floor surface. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
842
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 843
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 207 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
844
Priority:
Restrooms Finding:
The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 845
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 208 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
846
Priority:
Restrooms Finding:
The distance from the end of the side grab bar to the back wall in the stall designated to be accessible in the restroom is greater than 12 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 847
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 209 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
849
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 850
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 210 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Carnival Area Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
851
Priority:
Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 1104
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 211 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are 12 stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost: Record Number
4000 1105
Priority:
Restrooms Finding:
The latch side approach to the stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1106
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 212 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1107
Priority:
Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 1108
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 213 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost: Record Number
448 1109
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 1110
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 214 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost: Record Number
1143 1112
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1113
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 215 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost: Record Number
1286 1114
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 1115
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 216 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1116
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1117
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 217 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the hand dryer in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Delta Speedway (West End) Full Rec
Relocate the hand dryer in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1118
Priority:
Restrooms Finding:
There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 862
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 218 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
863
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 864
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 219 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
865
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
866
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 220 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
867
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 868
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 221 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the right grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Remount the right grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
869
Priority:
Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 870
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 222 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
871
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
872
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 223 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
873
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 874
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 224 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (East End) Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
875
Priority:
Restrooms Finding:
There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
The restroom is designated accessible and should be made accessible for the facility Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 876
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 225 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 24 inches of clearance on the latch side of the exterior entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 24 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
877
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 878
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 226 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no level landing provided at the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Provide a level and clear landing at least 60 inches in length in the direction of the door swing.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
879
Priority:
Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall. The flush control valve on the urinal is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 880
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 227 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The length of the back grab bar in the stall designated to be accessible of the restroom is less than 36 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Replace the back grab bar in the stall designated to be accessible of the restroom with a 36-inch back grab bar complying with ADAAG 4.26 and CBC 1115B.8. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
881
Priority:
Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 882
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 228 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
883
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 884
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 229 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
885
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 886
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 230 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Grandstands (North End) Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
887
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface and does not include the ISA symbol.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 1084
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 231 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
1085
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 1086
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 232 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
1087
Priority:
Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1088
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 233 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
1089
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost: Record Number
4000 1090
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 234 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
1091
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost: Record Number
1707 1093
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 235 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1094
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1095
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 236 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
1096
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 1097
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 237 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
1098
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1099
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 238 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Maintenance Facility Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1100
Priority:
Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 583
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 239 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The door opening force for the exterior door is greater than 5 pounds of force.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).
Citation
CBC 1133B.2.5; ADAAG 4.13.11
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
5
Maximum Estimated Cost:
5
Record Number
584
Priority:
Restrooms Finding:
The height of the side and back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 585
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 240 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
586
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
587
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 241 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the RV Park Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
588
Priority:
Restrooms Finding:
There is signage indicating accessibility on the entry door to the restroom. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1127
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 242 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost: Record Number
951 1128
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost: Record Number
4000 1129
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 243 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost: Record Number
1143 1130
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1131
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 244 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom at the Winner's Gaming and Sports Emporium Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
1132
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 494
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 245 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
750
Maximum Estimated Cost:
750
Record Number
495
Priority:
Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 496
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 246 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
497
Priority:
Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
498
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 247 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
499
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically. The inside handle on the stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
500
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 248 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
501
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
502
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 249 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
503
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
504
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 250 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
505
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 506
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 251 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
507
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in Building 3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 508
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 252 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
380
Priority:
Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
381
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 253 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
382
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 383
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 254 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor. The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
384
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 385
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 255 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
386
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 387
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 256 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
388
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in the Administration Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 389
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 257 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is signage indicating accessibility on the entry door to the restroom. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1119
Priority:
Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 1120
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 258 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1121
Priority:
Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1122
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 259 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost: Record Number
1143 1123
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1124
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 260 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1125
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom in the Winner's Building (Champions Section) Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 1126
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 261 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
901
Priority:
Restrooms Finding:
The urinal in the restroom does not extend at least 14 inches from the back wall. The height of the urinal rim is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
951 951 902
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 262 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
903
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 904
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 263 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
905
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
907
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 264 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
908
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 909
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 265 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
910
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 911
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 266 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
912
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 913
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 267 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
914
Priority:
Restrooms Finding:
The clear opening width of the entrance to the showers in the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Widen the entrance doorway to the showers in the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 915
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 268 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Consult a design professional to provide a latch-side approach to the stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
916
Priority:
Restrooms Finding:
Showering facilities are provided, though are not required. The restroom provides two private shower stalls. There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn C Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
917
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 269 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
935
Priority:
Restrooms Finding:
The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
269 269 936
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 270 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.
Citation
CBC 1115B.9.4; ADAAG 4.18.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
937
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 938
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 271 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
939
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
941
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 272 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
942
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
943
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 273 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
944
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 945
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 274 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
946
Priority:
Restrooms Finding:
The soap dish in the shower compartment designated to be accessible in the restroom is mounted at a height greater than 40 inches above the shower floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to Horse Barn K Full Rec
Relocate the soap dish mounted in the shower compartment designated to be accessible in the restroom so that it is mounted on the same wall as the water controls at a maximum height of 40 inches above the shower floor (see CBC 1115B.6.2.4.6).
Citation
CBC 1115B.6.2.4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1200
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 275 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
700
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 701
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 276 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The urinal in the restroom is floor mounted and does not provide a tapered, elongated rim.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
702
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
703
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 277 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
704
Priority:
Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 705
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 278 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
706
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
707
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 279 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
708
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
709
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 280 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
710
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 711
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 281 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Next to the Livestock Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 712
Priority:
Restrooms Finding:
There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 888
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 282 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
889
Priority:
Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 890
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 283 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 891
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
892
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 284 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
893
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
894
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 285 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
895
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 649
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 286 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
128 Sq Ft
Minimum Estimated Cost:
1024
Maximum Estimated Cost:
1024
Record Number
650
Priority:
Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
651
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 287 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
652
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
653
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 288 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
654
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 655
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 289 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
656
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
657
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 290 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
658
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 659
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 291 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
660
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 661
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 292 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
662
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 2 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 663
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 293 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage on the entrance door is not mounted at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
509
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 510
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 294 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
511
Priority:
Restrooms Finding:
The door to the stall designated to be accessible in the restroom does not close automatically. The inside handle on the stall door designated to be accessible.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
269 269 512
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 295 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
513
Priority:
Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 514
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 296 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
515
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 516
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 297 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
517
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 518
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 298 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Restroom Outside of Building 3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
519
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 714
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 299 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
715
Priority:
Restrooms Finding:
The height of the urinal rim in the restroom is greater than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Lower the urinal designated to be accessible in the restroom so that the rim height is not more than 17 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1097
Maximum Estimated Cost:
1097
Record Number
716
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 300 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the urinal flush control in the restroom is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Lower the flush control valve on the urinal designated to be accessible in the restroom to a height not greater than 44 inches above the finished floor (see ADAAG 4.18.4).
Citation
ADAAG 4.18.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
717
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
718
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 301 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
719
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 720
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 302 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
721
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
722
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 303 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
723
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
724
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 304 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
725
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 726
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 305 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
727
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 728
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 306 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no accessible showers provided.
Alternative Rec: (Where Available)
*
Men's Showers Next to the Livestock Office Full Rec
Since open showers are provided in the restroom, at least one accessible shower is required. Install an accessible shower in one of the corners with L-shaped grab bars extending along the two walls with a folding seat adjacent to the shower controls in the restroom (see CBC 1115B.6.3 and ADAAG 4.21).
Citation
CBC 1115B.6.3; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
3260
Maximum Estimated Cost:
3260
Record Number
729
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 947
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 307 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
750
Maximum Estimated Cost:
750
Record Number
948
Priority:
Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 949
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 308 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the threshold at the entrance door to the restroom is greater than 1/2 inch.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Install a ramp or threshold treatment ramp with a slope no greater than 8.33% to the entrance of the restroom complying with CBC 1133B.5 and ADAAG 4.8 when technically infeasible to modify the threshold.
Citation
ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2500
Maximum Estimated Cost:
2500
Record Number
950
Priority:
Restrooms Finding:
This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.
Citation
CBC 1115B.7.2; ADAAG 4.16.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 951
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 309 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the restroom.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
952
Priority:
Restrooms Finding:
The height of the toilet seat in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Remove or modify the toilet in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
954
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 310 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
955
Priority:
Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 956
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 311 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The lavatory in the restroom is in an enclosed cabinet, thereby preventing an accessible forward approach. The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Lavatories in restrooms must provide clear floor space in front of the lavatory for an accessible forward approach and shall provide at least 29 inches clear knee space and a minimum of nine inches clear toe space (see ADAAG 4.19.2). If neither clear floor space and knee and toe clearance can be provided, remove the lavatory cabinet and replace with an accessible wallmounted lavatory unit.
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
420
Maximum Estimated Cost:
420
Record Number
957
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 958
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 312 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
959
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 6 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 960
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 313 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
677
Priority:
Restrooms Finding:
The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 678
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 314 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bar in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
679
Priority:
Restrooms Finding:
The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 680
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 315 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the restroom is greater than 19 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Remove or modify the toilet in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
681
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
682
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 316 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
683
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 684
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 317 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
685
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 7 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 686
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 318 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
665
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 666
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 319 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
667
Priority:
Restrooms Finding:
This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.
Citation
CBC 1115B.7.2; ADAAG 4.16.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 668
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 320 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the restroom.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
669
Priority:
Restrooms Finding:
The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 670
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 321 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
671
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 672
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 322 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
673
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 674
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 323 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
675
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 676
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 324 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
759
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 760
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 325 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
761
Priority:
Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the restroom from the pull side.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 762
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 326 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the restroom.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
763
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
765
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 327 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
766
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 767
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 328 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
768
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 769
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 329 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
770
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 771
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 330 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at Building 8 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
772
Priority:
Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 609
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 331 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 48 inches of clear floor space provided in front of the water closet in the restroom to allow an accessible forward approach.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
The minimum clear floor space in front of the water closet designated to be accessible in the restroom shall be at least 30 inches by 48 inches to provide an accessible forward approach. Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the water closet.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
610
Priority:
Restrooms Finding:
The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 611
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 332 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
Remount the back grab bar in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
612
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
613
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 333 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the First Aid Building Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
614
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 1030
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 334 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1031
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 1032
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 335 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
1034
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost: Record Number
1707 1035
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 336 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1036
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1037
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 337 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
1038
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 1039
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 338 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
1040
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1041
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 339 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Jockey's Quarters Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1042
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 790
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 340 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Remount the side grab bar in the restroom so that the height of the gripping surface is centered at 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
791
Priority:
Restrooms Finding:
The location of the toilet paper dispenser in the restroom is not within 12 inches of the front edge of the toilet seat. t.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Remount the toilet paper dispenser in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 792
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 341 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Relocate the flush control on the toilet in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
793
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Relocate the toilet so that the distance from the centerline of the toilet to the nearest side wall in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
794
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 342 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Relocate the seat cover dispenser in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
795
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 796
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 343 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom at the Livestock Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
797
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 442
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 344 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
750
Maximum Estimated Cost:
750
Record Number
443
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
444
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 345 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
445
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 446
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 346 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
447
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
448
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 347 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
449
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 450
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 348 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
451
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 452
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 349 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
453
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Unisex Restroom in the Stable Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 454
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 350 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
743
Priority:
Restrooms Finding:
The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 744
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 351 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
745
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 746
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 352 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
747
Priority:
Restrooms Finding:
The height of the left grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor. The height of the right grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Remount the side and back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 748
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 353 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The right grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
749
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
751
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 354 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
752
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 753
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 355 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
754
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 755
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 356 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
756
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 757
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 357 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 1 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
758
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door to the restroom and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 730
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 358 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are eight stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
731
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
732
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 359 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
733
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 734
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 360 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
735
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
736
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 361 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
737
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
738
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 362 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
739
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 740
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 363 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
741
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 2 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 742
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 364 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and does not include the International Symbol of Accessibility.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
977
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 978
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 365 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
979
Priority:
Restrooms Finding:
The privacy partition at the entrance limits the minimum clear width of the accessible route into the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Modify or remove the privacy partition at the entrance to the restroom to provide a width of at least 60 inches in the direction of the door swing and at least 48 inches in the opposite direction of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and ADAAG Figure 25).
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 980
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 366 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
981
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 982
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 367 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
983
Priority:
Restrooms Finding:
The height of the left grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor. The height of the right grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 984
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 368 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
985
Priority:
Restrooms Finding:
The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Remount or replace the toilet paper dispenser so that it does not encroach more than four inches from the face of the wall. Make sure it does not interfere with the use of the side grab bar (see ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and be mounted within 12" in front of the water closet.
Citation
DSA Access Policy 99-07
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 986
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 369 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet. The flush controls are nonaccessible and requires the use of foot controls to operate.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
987
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
988
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 370 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
989
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 990
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 371 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
991
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
992
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 372 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
993
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 994
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 373 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 4 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
995
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 540
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 374 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
750
Maximum Estimated Cost:
750
Record Number
541
Priority:
Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 542
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 375 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
543
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
544
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 376 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
545
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 546
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 377 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
547
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 548
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 378 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Building 5 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
549
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include Braille or the ISA symbol.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 1073
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 379 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1074
Priority:
Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 1075
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 380 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
1076
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 1078
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 381 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
1079
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost: Record Number
1143 1080
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 382 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1081
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost: Record Number
1286 1082
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 383 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The controls and operating mechanisms on the paper towel dispenser in the restroom require tight grasping, pinching, or twisting of the wrist and the use of two hands to operate. The height of the operating controls on the dispenser is at a height greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Flat's BBQ Full Rec
Modify or replace the paper towel dispenser in the restroom so that its controls and operating mechanisms can be operated with one hand and comply with ADAAG 4.27.4 and CBC 1117B.6.4. Make certain that the force to activate the operating controls shall be no greater than 5 pounds and that the height shall be no greater than 40 inches above the finished floor.
Citation
ADAAG 4.27.4, CBC 1117B.6.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
1083
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 572
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 384 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
573
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 574
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 385 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
575
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
576
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 386 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
577
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 578
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 387 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
579
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 580
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 388 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
581
Priority:
Restrooms Finding:
There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 1 Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
582
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 389 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage indicating accessibility at the entry to the restroom is not mounted on the latch side of the entrance door and is not centered at 60 inches above the floor surface. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
550
Priority:
Restrooms Finding:
The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
269 269 551
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 390 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
552
Priority:
Restrooms Finding:
There is less than 48 inches of clear floor space provided in front of the toilet in the restroom to allow an accessible forward approach.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
The minimum clear floor space in front of the toilet designated to be accessible in the restroom shall be at least 48 inches to provide an accessible forward approach (see CBC 1115B.9.4 and ADAAG 4.18.3). Consult a design professional to determine if elements or walls need to be removed to provide sufficient clear floor space in front of the toilet.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 553
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 391 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
554
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
555
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 392 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
556
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 557
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 393 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
558
Priority:
Restrooms Finding:
The hand-held sprayer unit is mounted at a height greater than 48 inches above the finished floor. The length of the hose for the hand-held sprayer unit is less than 60 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Install a hand-held sprayer unit in the shower compartment designated to be accessible in the restroom with a hose at leapt 60 inches in length. The centerline of the hand-held sprayer unit shall be mounted within 27 inches from the rear seat edge and at a height no greater than 48 inches from the finished floor (see CBC 1115B.6.2.4.2).
Citation
ADAAG 4.21.6; CBC 1115B.6.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
385 385 1201
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 394 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
829
Priority:
Restrooms Finding:
There is less than 12 inches of latch side clearance from the push side of the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 12 inches of latch side clearance at the entrance door from the push side (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device to the primary entrance complying with ADAAG 4.13.12 and ANSI/BHMA A156.10, 1985, standards.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 830
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 395 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The inside handle on the stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
831
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 832
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 396 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bars in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
833
Priority:
Restrooms Finding:
The left grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 834
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 397 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
835
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 836
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 398 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
837
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 838
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 399 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the rim surface of the lavatory designated to be accessible in the restroom is greater than 34 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate or replace the lavatory designated to be accessible in the restroom to provide a maximum rim surface height of no greater than 34 inches above the finished floor (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
839
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 840
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 400 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at L-1 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
841
Priority:
Restrooms Finding:
The signage indicating accessibility on the latch side of the entry door of the restroom does not include Braille or raised lettering and is not centered at 60 inches above the floor surface. The gender use signage on the entrance door is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 641
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 401 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
642
Priority:
Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 643
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 402 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
644
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
645
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 403 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
646
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 647
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 404 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Carnival Area Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
648
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 403
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 405 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are 14 stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
404
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
405
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 406 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
406
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 407
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 407 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
408
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
409
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 408 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
410
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 411
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 409 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
412
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the hand dryer in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the Delta Speedway Full Rec
Relocate the hand dryer in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 413
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 410 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage indicating accessibility at the entry door of the restroom is not mounted on the latch side of the entrance door and is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
The restroom is designated accessible and should be made accessible for the facility, incorporating children's height standards set forth in the Final Rule amending ADAAG, January 13, 1998. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 615
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 616
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 411 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The door to the alternate stall designated to be accessible in the restroom does not close automatically or have accessible hardware. The inside handle on the standard stall door designated to be accessible in the restroom is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
269 269 617
Priority:
Restrooms Finding:
The height of the side grab bar in the standard stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 618
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 412 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the standard stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 619
Priority:
Restrooms Finding:
The side grab bars in the standard stall and the alternate stall designated to be accessible in the restroom do not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 620
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 413 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the standard stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
621
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 622
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 414 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom at the First Floor of the Grandstands Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
623
Priority:
Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom at the Soccer Field Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 897
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 415 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 12 inches of clearance on the latch side of the exterior entrance door from the push side.
Alternative Rec: (Where Available)
*
Women's Restroom at the Soccer Field Full Rec
Provide at least 12 inches of latch side clearance at the entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise, install an automatic door opening device.
Citation
ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
898
Priority:
Restrooms Finding:
The door opening force for the exterior door is greater than 5 pounds of force.
Alternative Rec: (Where Available)
*
Women's Restroom at the Soccer Field Full Rec
Adjust the closers on all exterior doors to a maximum door opening force of 5 pounds of force (see ADAAG 4.13.11 and CBC 1133B.2.5).
Citation
CBC 1133B.2.5; ADAAG 4.13.11
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
5
Maximum Estimated Cost: Record Number
5 899
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 416 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door is not centered at 60 inches above the floor surface and does not include Braille or the ISA symbol.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
996
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 997
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 417 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
998
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 999
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 418 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The inside handle on the stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Install a loop or U-shaped handle immediately below the latch hardware on the door to the stall designated to be accessible in the restroom (see CBC 1115B.7.1.3 and ADAAG 4.13.9). Leveroperated or push-type mechanisms may also be used. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting.
Citation
CBC 1115B.7.1.3; ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
189
Maximum Estimated Cost:
189
Record Number
1000
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1001
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 419 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the back grab bar in the stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
1002
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 1003
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 420 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1004
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 1005
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 421 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
1006
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost: Record Number
1143 1007
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 422 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no clear floor space provided in front of the seat cover dispenser.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1008
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 1009
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 423 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
1010
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 1011
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 424 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
1012
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1013
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 425 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in Building 3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1014
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 480
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 426 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
481
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. There is no door on the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
482
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 427 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
483
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
484
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 428 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
485
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 486
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 429 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
392
Maximum Estimated Cost:
392
Record Number
487
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
488
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 430 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
489
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 490
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 431 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
491
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 492
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 432 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Jockey Annex Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
493
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage on the entrance door does not include Braille or the ISA symbol.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 1133
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 433 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1134
Priority:
Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1135
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 434 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
1136
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 1137
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 435 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The toilet paper dispenser protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Remount or replace the toilet paper dispenser so that it does not encroach more than four inches from the face of the wall. Make sure it does not interfere with the use of the side grab bar (see ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and be mounted within 12" in front of the water closet.
Citation
DSA Access Policy 99-07
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1138
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is greater than 19 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost: Record Number
1707 1139
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 436 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1140
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost: Record Number
1286 1141
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 437 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Main Office Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1142
Priority:
Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 414
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 438 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
750
Maximum Estimated Cost:
750
Record Number
415
Priority:
Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
204 204 416
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 439 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The urinal in the restroom is floor mounted and does not provide a tapered, elongated rim. The flush control valve on the urinal is greater than 44 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Replace the urinal designated to be accessible in the restroom with a wall-mounted or stall-type tapered, elongated rim unit complying with ADAAG 4.18.2. The height of the rim surface of the urinal designated to be accessible shall not exceed 17 inches above the finished floor and the flush control valve shall not exceed a height of 44 inches above the finished floor.
Citation
ADAAG 4.18.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
951
Maximum Estimated Cost:
951
Record Number
417
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
418
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 440 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost:
531
Record Number
419
Priority:
Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 420
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 441 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
421
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
422
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 442 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
423
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 424
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 443 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
425
Priority:
Restrooms Finding:
The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 426
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 444 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
427
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 428
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 445 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
429
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 430
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 446 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no accessible shower stall provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the Maintenance Shop Full Rec
Since a shower stall is provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
441
Priority:
Restrooms Finding:
There is signage indicating accessibility on the entry door to the restroom in the San Joaquin Room at the Winners Gaming and Sports Emporium. The signage is centered 60 inches above the floor on the latch side of the entrance door and includes Braille and raised lettering, gender use symbol and the ISA symbol.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
The restroom is designated accessible and should be made an accessible restroom for the facility. Monitor signage for continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e)) and ADAAG 4.30.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 390
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 447 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There are eight stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
391
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
392
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 448 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
393
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 394
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 449 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom in the San Joaquin Room Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
395
Priority:
Restrooms Finding:
The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 396
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 450 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
397
Priority:
Restrooms Finding:
The side grab bar in the stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 398
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 451 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost: Record Number
277 399
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
400
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 452 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
401
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom in the Winners Gaming and Sports Emporium Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 402
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 453 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage indicating accessibility is not mounted on the latch side of the entry door of the restroom. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
468
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
469
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 454 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
470
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 471
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 455 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The flush control on the toilet in the stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
127
Maximum Estimated Cost:
127
Record Number
472
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
473
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 456 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
474
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 475
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 457 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
476
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 477
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 458 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
478
Priority:
Restrooms Finding:
A showering facility is provided, though is not required. There is no accessible shower stall provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 4 Full Rec
Since a shower stall is provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
479
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 459 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage indicating accessibility is not mounted on the latch side of the entry door to the restroom. The gender use signage on the entrance door is not mounted at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
455
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
456
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 460 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
457
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 458
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 461 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
459
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
460
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 462 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
461
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 462
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 463 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
463
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 464
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 464 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
465
Priority:
Restrooms Finding:
Showering facilities are provided, though are not required. There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn 5 Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
466
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 465 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage is not mounted on the entrance door and does not include Braille or raised lettering.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
918
Priority:
Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
919
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 466 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
920
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 921
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 467 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
923
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
924
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 468 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
925
Priority:
Restrooms Finding:
The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Raise or replace the lavatory designated to be accessible in the restroom to provide at least 27 inches at 8 inches under the apron. Make sure to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron and a rim surface height no greater than 34 inches (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
926
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 469 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
927
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 928
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 470 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
929
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 930
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 471 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The women's restroom provides two private shower stalls. There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the women's restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
931
Priority:
Restrooms Finding:
The clear opening width of the entrance to the showers in the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Widen the entrance doorway to the showers in the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 932
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 472 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is less than 18 inches on the latch side of the entrance door to the showers in the restroom from the pull side.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Consult a design professional to determine if it is technically feasible to provide at least 18 inches of latch side clearance at the entrance door to the restroom from the pull side (see ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door opening device may be required to provide an accessible entrance.
Citation
ADAAG 4.13.6; CBC 1133B.2.4.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
933
Priority:
Restrooms Finding:
The latch side approach to the shower stall designated to be accessible in the restroom is less than 44 inches wide.
Alternative Rec: (Where Available)
*
Women's Restroom Next to Horse Barn G Full Rec
Consult a design professional to provide a latch-side approach to the shower stall designated to be accessible with a clear, unobstructed access width of 44 inches with the space immediately in front of the stall door at 48 inches in width. All other approaches require 48 inches of clear, unobstructed access to and in front of the stall designated to be accessible in the restroom.
Citation
CBC 1115B.7.1.3; ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 934
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 473 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
814
Priority:
Restrooms Finding:
The clear opening width of the entrance doorway to the restroom is less than 32 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Widen the entrance doorway to the restroom to provide a clear opening width of at least 32 inches when the door is open 90 degrees (see ADAAG 4.13.5).
Citation
ADAAG 4.13.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
750 750 815
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 474 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The entrance door to the restroom has a round doorknob that requires tight grasping or twisting of the wrist to operate.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Replace the door hardware mounted on the restroom complying with ADAAG 4.13.9. Make certain accessible door hardware is mounted no higher than 48 inches above the finished floor.
Citation
ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
204
Maximum Estimated Cost:
204
Record Number
816
Priority:
Restrooms Finding:
There are seven stalls located in the multiple accommodation restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Create an accessible 36-inch wide alternate stall in addition to the required accessible standard stall in the multiple accommodation restroom. The accessible 36-inch wide alternate stall shall include an outward swinging, self-closing door and parallel side grab bars and shall provide at least 66 inches in length for a stall with a wall-mounted toilet or at least 69 inches in length for a stall with a floor-mounted toilet.
Citation
CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG 4.22.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
817
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 475 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The door to the stall designated to be accessible in the restroom does not close automatically or have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
818
Priority:
Restrooms Finding:
There is no back grab bar in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Install a 36-inch back grab bar at a height of 33 inches above the finished floor in the stall designated to be accessible of the restroom. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 819
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 476 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the left grab bar in the stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Remount the left grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
820
Priority:
Restrooms Finding:
The side grab bars in the stall designated to be accessible in the restroom do not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 821
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 477 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat and does not encroach more than four inches from the face of the wall (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
822
Priority:
Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
823
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 478 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is greater than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
824
Priority:
Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 825
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 479 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
826
Priority:
Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
39 39 827
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 480 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Next to L-2 and L-3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
828
Priority:
Restrooms Finding:
The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 598
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 481 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The door to the stall designated to be accessible in the restroom does not close automatically.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
269
Maximum Estimated Cost:
269
Record Number
599
Priority:
Restrooms Finding:
The height of the coat hook on the standard stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 600
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 482 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the side grab bar in the standard stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Remount the side grab bar in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
601
Priority:
Restrooms Finding:
The side grab bar in the standard stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
The front end of the grab bar shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 602
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 483 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the standard stall and the alternate stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Remount the toilet paper dispenser in the stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
603
Priority:
Restrooms Finding:
The flush control on the toilet in the alternate stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the flush control on the toilet in the stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 604
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 484 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the standard stall and the alternate stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
605
Priority:
Restrooms Finding:
The seat cover dispenser in the standard stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 606
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 485 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
607
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom on the Second Floor of the Grandstands Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 608
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 486 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The signage on the latch side of the entry door of the restroom does not include the International Symbol of Accessibility. The gender use signage is not mounted outside of the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
1015
Priority:
Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the doorstop.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1016
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 487 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the standard stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Modify or replace the standard stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wallmounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
1017
Priority:
Restrooms Finding:
The door to the alternate stall designated to be accessible in the restroom does not close automatically or have accessible hardware. The inside handle on the standard stall door is not mounted immediately below the latch.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Provide an automatic door closer, spring hinge, pull bar or accessible handle mounted on the inside of the stall door to the stall designated to be accessible in the restroom (see ADAAG A4.17.5). Accessible hardware on the inside and outside of the stall designated to be accessible door shall be equipped with a loop or U-shaped handle mounted immediately below the latch. The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting. Make certain that the inside and outside door hardware is mounted no more than 48 inches above the finished floor (see CBC 115B.7.1.3 and ADAAG 4.13.9).
Citation
ADAAG A4.17.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
269 269 1018
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 488 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the standard stall door and alternate stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
1019
Priority:
Restrooms Finding:
The height of the side grab bars in the standard stall and the alternate stall designated to be accessible of the restroom is less than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Remount the side grab bars in the standard stall and alternate stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 1020
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 489 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the end of the back grab bar to the nearest side wall in the stall designated to be accessible of the restroom is greater than 6 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Remount the back grab bar in the stall designated to be accessible in the restroom so that it is not more than 6 inches from the nearest side wall (see ADAAG 4.26 and CBC Figure 11B.1A-1C). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
ADAAG 4.26; CBC 1115B.8.1
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
448
Maximum Estimated Cost:
448
Record Number
1021
Priority:
Restrooms Finding:
The distance from the end of the side grab bars to the back wall in the alternate stall designated to be accessible in the restroom is greater than 12 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Remount the side grab bars in the alternate stall designated to be accessible in the restroom so that it is not more than 12 inches from the back wall (see ADAAG Figure 29 and CBC 1115B.8). Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 1022
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 490 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The location of the toilet paper dispenser in the standard stall designated to be accessible in the restroom is not within 12 inches of the front edge of the toilet seat. The toilet paper dispenser in the alternate stall designated to be accessible in the restroom protrudes more than 4 inches from the side wall and interferes with the clear floor space of the water closet.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Remount the toilet paper dispenser in the standard stall and alternate stall designated to be accessible in the restroom so that it is within 12 inches from the front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper dispensers must allow continuous paper flow and shall not interfere with the use of the side grab bar.
Citation
CBC 1115B.9.3; ADAAG 4.16.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1023
Priority:
Restrooms Finding:
The flush control on the toilet in the alternate stall designated to be accessible in the restroom is not on the wide (approach) side of the toilet.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Relocate the flush control on the toilet in the alternate stall designated to be accessible in the restroom so that it is on the wide (approach) side of the toilet area (see ADAAG 4.16.5). Flush controls shall be hand-operated or automatic mechanisms.
Citation
ADAAG 4.16.5; ADAAG 4.27.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
127 127 1024
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 491 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the standard stall and alternate stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the standard stall and alternate stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
1025
Priority:
Restrooms Finding:
The seat cover dispenser in the standard stall and alternate stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1026
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 492 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
291
Maximum Estimated Cost:
291
Record Number
1027
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1028
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 493 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of Building 3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 1029
Priority:
Restrooms Finding:
The signage indicating accessibility on the latch side of the entry door of the restroom is not centered at 60 inches above the floor surface. There is no Title 24 gender use signage on the entrance door.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
58 58 589
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 494 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The bottom 10 inches of the door does not provide a smooth, uninterrupted surface, or panel to allow the door to be opened by a wheelchair footrest without creating a trap or hazardous condition, due to the door stop.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Install a panel or replace the door to provide a smooth, uninterrupted surface for the bottom 10 inches of the door.
Citation
CBC 1133B.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 590
Priority:
Restrooms Finding:
The door in the standard stall designated to be accessible in the restroom does not have appropriate accessible hardware.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
The latch shall be flip-over style, sliding or other hardware not requiring grasping or twisting.
Citation
CBC 1115B.7.1.3; ADAAG 4.13.9
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
189 189 591
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 495 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the coat hook on the standard stall door designated to be accessible in the restroom is greater than 48 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Remount the coat hook on the stall door designated to be accessible in the restroom to a maximum height of 48 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 592
Priority:
Restrooms Finding:
The height of the side grab bars in the alternate stall designated to be accessible of the restroom is greater than 33 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Remount the side grab bars in the stall designated to be accessible in the restroom so that the height of the gripping surface is centered at 33 inches above finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
448 448 593
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 496 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The side grab bars in the standard stall and the alternate stall designated to be accessible in the restroom does not extend 54 inches from the back wall.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
The front end of the grab bars shall extend at least 54 inches from the back wall and the back end of the grab bar shall be mounted within 12 inches from the back wall. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8.1; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
531
Maximum Estimated Cost: Record Number
531 594
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the standard stall designated to be accessible in the restroom is greater than 18 inches. The distance from the center of the toilet to the nearest side wall in the alternate stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
595
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 497 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
596
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Restroom Outside of the Grandstands (North End) Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 597
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 498 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is no signage indicating accessibility on the latch side of the entry door of the restroom. The gender use signage is not mounted on the entrance door and is not centered at 60 inches above the floor surface.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
The restroom is designated accessible and should be made accessible for the facility. Post signage centered 60 inches above the ground surface on the latch side of the entrance door identifying the restroom as accessible upon completion of the following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Signage shall include Braille and raised lettering, the gender or unisex use symbol and the ISA symbol. Post Title 24 gender use signage on the door @ 60" o.c. a.f.f.
Citation
CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7)); ADAAG 4.1.6(3)(e); ADAAG 4.30
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
58
Maximum Estimated Cost:
58
Record Number
798
Priority:
Restrooms Finding:
This restroom is not accessible and cannot be easily altered. There is not sufficient clear floor space in the restroom to accommodate an individual in a wheelchair.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Consult a design professional to modify the restroom. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the restroom to accommodate an individual in a wheelchair.
Citation
CBC 1115B.7.2; ADAAG 4.16.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 799
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 499 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
There is insufficient clear floor space in the stall designated to be accessible in the restroom. The stall door to the stall designated to be accessible in the restroom swings inward limiting the clear floor space in the stall designated to be accessible. The door to the stall designated to be accessible in the restroom does not have accessible hardware.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Modify or replace the stall designated to be accessible in the restroom so that it complies with ADAAG 4.17.3, CBC 1115B and CBC Figures 11B-1A and 1B. Standard accessible stalls require 60 inches in width with 56 inches depth for wall-mounted toilets or 59 inches depth for floor-mounted toilets to accommodate individuals in wheelchairs. The minimum width of a front-approach doorway shall provide at least 32 inches and a side-approach doorway shall provide at least 34 inches. The door shall swing outward, close automatically and provide accessible hardware.
Citation
CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
4000
Maximum Estimated Cost:
4000
Record Number
800
Priority:
Restrooms Finding:
There are no grab bars in the stall designated to be accessible in the restroom.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Install one 36-inch back grab bar and one 42/48-inch side grab bar in the stall designated to be accessible in the restroom. Grab bars shall be mounted at a height of 33 inches above the finished floor. Grab bars must be able to support a point load of at least 250 pounds and shall be less than the allowable shear stress of the grab bar material.
Citation
CBC 1115B.8; ADAAG 4.26
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
531 531 801
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 500 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the toilet seat in the stall designated to be accessible in the restroom is less than 17 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Remove or modify the toilet in the stall designated to be accessible in the restroom so that the seat height is between 17 inches and 19 inches above the finished floor (see ADAAG 4.16.3).
Citation
ADAAG 4.16.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1707
Maximum Estimated Cost:
1707
Record Number
803
Priority:
Restrooms Finding:
The distance from the center of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Relocate the toilet or stall side wall so that the distance from the centerline of the toilet to the nearest side wall in the stall designated to be accessible in the restroom is exactly 18 inches (see ADAAG Figure 28.
Citation
CBC 1115B.7.1.3 ADAAG 4.17.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1143
Maximum Estimated Cost:
1143
Record Number
804
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 501 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The seat cover dispenser in the stall designated to be accessible in the restroom is mounted at a height greater than 40 inches and there is no clear floor space.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Relocate the seat cover dispenser in the stall designated to be accessible in the restroom so that the height is no greater than 40 inches above the finished floor (see CBC 1115B.9.2). Make certain that the location of the seat cover dispenser does not interfere with the use of a grab bar and provides sufficient clear floor space.
Citation
CBC 1115B.9.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
805
Priority:
Restrooms Finding:
The faucet controls on the lavatory in the restroom require tight grasping, pinching, or twisting of the wrist and are not accessible.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Install faucet controls complying with ADAAG 4.19.5 on the lavatory designated to be accessible in the restroom. Leveroperated, push-type, touch-type or electronically controlled mechanisms are acceptable elements (see ADAAG 4.19.5). If self-closing valves are used the faucet shall remain open for at least 10 seconds.
Citation
ADAAG 4.19.5
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
392 392 806
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 502 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The distance from the center of the lavatory to the adjacent side wall in the restroom is less than 18 inches.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Relocate the lavatory to provide a centerline of at least 18 inches. Make sure to provide at least 30 inches in width and 48 inch length of clear floor space to allow an accessible forward approach (see ADAAG 4.19.3).
Citation
ADAAG 4.19.3
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost:
0
Record Number
807
Priority:
Restrooms Finding:
The knee clearance space under the lavatory designated to be accessible in the restroom is less than 29 inches. The knee depth space under the lavatory designated to be accessible in the restroom is less than 27 inches at 8 inches under the lavatory apron.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Replace the lavatory designated to be accessible in the restroom to provide at least 29 inches of clear knee space between the finished floor and bottom of the lavatory apron. Make sure to provide at least 27 inches at 8 inches under the apron (see ADAAG 4.19.2).
Citation
ADAAG 4.19.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
1286
Maximum Estimated Cost:
1286
Record Number
808
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 503 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The pipes under the lavatory in the restroom do not provide protection against contact.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Insulate or otherwise configure pipes under the lavatory designated to be accessible in the restroom to protect against contact (see ADAAG 4.19.4). Make certain there are no sharp or abrasive surfaces under the lavatory.
Citation
ADAAG 4.19.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
39
Maximum Estimated Cost:
39
Record Number
809
Priority:
Restrooms Finding:
The bottom edge of the reflecting surface of the mirror in the restroom is greater than 40 inches above the finished floor.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Lower the mirror in the restroom so that the bottom edge of the reflecting surface is no higher than 40 inches above the finished floor and the topmost portion of the reflecting surface extends at least 74 inches above the finished floor (see ADAAG A4.19.6). A single, full-length mirror is recommended since it can accommodate all people. Make certain to provide a minimum clear floor space in front of the mirror of 30 inches in width and 48 inches in length.
Citation
ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG 4.19.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
291 291 810
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 504 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The height of the controls and operating mechanisms for the soap dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Relocate the soap dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
811
Priority:
Restrooms Finding:
The height of the controls and operating mechanisms for the paper towel dispenser in the restroom is greater than 40 inches.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Relocate the paper towel dispenser in the restroom to a maximum height of 40 inches for all the controls and operating mechanisms (see CBC 1115B.9.2).
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
277 277 812
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 505 of 542
Facility Name: San Joaquin Fairgrounds Restrooms Finding:
The women's restroom provides four private shower stalls. There are no accessible shower stalls provided in the restroom.
Alternative Rec: (Where Available)
*
Women's Showers Next to L-2 and L-3 Full Rec
Since shower stalls are provided in the restroom, at least one accessible shower stall is required. Install an accessible shower stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the restroom.
Citation
CBC 1115B.6.2; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2853
Maximum Estimated Cost:
2853
Record Number
813
Priority:
Drinking Fountains Finding:
There are 13 drinking fountains on primary paths of travel.
Alternative Rec: (Where Available)
*
Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirement. Fountains not located in alcoves need side rails or wing walls on both sides.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1143
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 506 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height. The drinking fountain does not have accessible fountain controls and requires the use of foot controls to operate.
Alternative Rec: (Where Available)
*
Drinking Fountain at the West Entrance of Building 2 Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost:
2216
Record Number
664
Priority:
Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The water trajectory is diagonal to the front of the unit.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 1 (East Entrance) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The spout shall direct the water flow at least 4 inches high and in a trajectory that is parallel or nearly parallel to the front of the drinking fountain.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1145
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 507 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 1 (North Entrance) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost:
2216
Record Number
1153
Priority:
Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 2 (North Entrance) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1152
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 508 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 2 (South Entrance) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost:
2216
Record Number
1151
Priority:
Drinking Fountains Finding:
The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height. The drinking fountain is not a "high-low" design.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 2 (West Entrance) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1144
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 509 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The spout outlet height is greater than 36 inches. The faucet controls require the use of foot controls to operate. There is less than 27 inches knee clearance height. The drinking fountain is not a "high-low" design.
Alternative Rec: (Where Available)
*
Drinking Fountain in Building 6 Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost:
2216
Record Number
1147
Priority:
Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.
Alternative Rec: (Where Available)
*
Drinking Fountain in the Grandstands (East End) Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1150
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 510 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The faucet controls require tight grasping or pinching of the wrist to operate.
Alternative Rec: (Where Available)
*
Drinking Fountain in the Jockey's Quarters Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. Fountain controls shall be accessible.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1146
Priority:
Drinking Fountains Finding:
The drinking fountain is not a "high-low" design.
Alternative Rec: (Where Available)
*
Drinking Fountain Next to the Restrooms in the Winner's Building Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. Provide at least 30 inches in width and 48 inches in depth in front of the drinking fountain. The height of the spout outlet shall not exceed 36 inches in height. Fountain controls shall be accessible. The spout shall direct the water flow at least 4 inches high and in a trajectory that is parallel or nearly parallel to the front of the drinking fountain. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
2216 1149
Priority:
Page 511 of 542
Facility Name: San Joaquin Fairgrounds Drinking Fountains Finding:
The drinking fountain is not a "high-low" design. The spout outlet height is greater than 36 inches. There is less than 27 inches knee clearance height.
Alternative Rec: (Where Available)
*
Drinking Fountains Next to the Restrooms in the Grandstands Full Rec
Fifty percent of the drinking fountains on primary paths of travel shall be accessible (see CBC 1117B.1 and ADAAG 4.15). Install a "high-low" fountain design to comply with both state and federal requirements and install a side rail or wing wall next to each side of the fountain. The height of the spout outlet shall not exceed 36 inches in height. Wall-mounted drinking fountains shall provide a minimum knee clearance height of 27 inches, 30 inches in width and between 18 inches and 19 inches in fountain depth.
Citation
CBC 1117B.1; ADAAG 4.15
Minimum Quantity
1
Maximum Quantity:
2
Unit:
Each
Minimum Estimated Cost:
2216
Maximum Estimated Cost: Record Number
4432 1148
Priority:
Commons or Lunch Area Finding:
The height of the tray slides is greater than 34 inches.
Alternative Rec: (Where Available)
*
Building 2 Kitchen Full Rec
Lower the tray slides to a height no greater than 34 inches above the finished floor (see CBC 1104B.5.5 and ADAAG 5.5).
Citation
CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3); ADAAG A4.2.5; ADAAG A4.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
30 Linear Feet
Minimum Estimated Cost:
2400
Maximum Estimated Cost:
2400
Record Number
355
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 512 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the concession counter at the north end of the Grandstand is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter at the Grandstand (North End) Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost:
129
Maximum Estimated Cost: Record Number
129 1165
Priority:
Commons or Lunch Area Finding:
The height of the concession counter at the north end of the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter at the Granstands (North End) Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1171
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 513 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the concession counter on the north end of the second level of the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter at the Granstands (North End) Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost:
129
Maximum Estimated Cost: Record Number
129 1172
Priority:
Commons or Lunch Area Finding:
The height of the concession counter at the south end of the second level in the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter in the Grandstands (South End) Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
2
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 258 1175
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 514 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the concession counter outside of Building 2 is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter Outside of Building 2 (South End) Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost:
129
Maximum Estimated Cost:
129
Record Number
1156
Priority:
Commons or Lunch Area Finding:
The height of the concession counter outside of the FFA Office is greater than 36 inches.
Alternative Rec: (Where Available)
*
Concession Counter Outside of the FFA Office Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1166
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 515 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The table top height is greater than 34 inches.
Alternative Rec: (Where Available)
*
Dining Area in the Grandstands Full Rec
Modify or replace one of the tables in the cafeteria to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1174
Priority:
Commons or Lunch Area Finding:
The height of the sales counter in Flats BBQ is greater than 34 inches.
Alternative Rec: (Where Available)
*
Flats BBQ Full Rec
Lower the sales counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).
Citation
CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 342
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 516 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the food service counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Food Service Counter in Building 2 (South End) Full Rec
Lower the food service counter to a height no greater than 34 inches above the finished floor (see CBC 1104B.5.5 and ADAAG 5.5).
Citation
CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3); ADAAG A4.2.5; ADAAG A4.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
30 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
2400 2400 1154
Priority:
Commons or Lunch Area Finding:
The height of the north west concession counter at the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 352
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 517 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
There is no level landing provided at the concession counter.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Provide a level and clear landing at least 60 inches in length at the concession counter.
Citation
CBC 1133B.2.4.2; ADAAG 4.13.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 353
Priority:
Commons or Lunch Area Finding:
The height of the south east concession counter in the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 358
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 518 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the north east concession counter in the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost:
129
Maximum Estimated Cost:
129
Record Number
360
Priority:
Commons or Lunch Area Finding:
The height of the bar counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Grandstands (Second Level) Full Rec
Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).
Citation
CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 1173
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 519 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the concession counter in the Linden Lions Building is greater than 36 inches.
Alternative Rec: (Where Available)
*
Linden Lions Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 351
Priority:
Commons or Lunch Area Finding:
The knee space at the tables is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Lyndon Lions Building Full Rec
Modify or replace one of the tables to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1170
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 520 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the concession counter at the Lyndon Lions Club is greater than 36 inches.
Alternative Rec: (Where Available)
*
Lyndon Lions Club Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1164
Priority:
Commons or Lunch Area Finding:
The knee space at the tables in the outdoor dining area at Building 2 is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Outdoor Dining Area Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1155
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 521 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
There is no accessible route to the picnic tables in the outdoor dining area outside of Flat's BBQ. The surface under and around the outdoor dining area picnic tables is dirt, preventing access of individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Outdoor Dining Area Outside of Flats BBQ Full Rec
Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.
Citation
ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
1162
Priority:
Commons or Lunch Area Finding:
The knee space at the tables in the outdoor dining area is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Outdoor Dining Area Outside of Flats BBQ Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1163
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 522 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The knee space at the tables in the outdoor dining area outside of the Champion's Room at the Winner's Gaming and Sports Emporium is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Outdoor Dining Area Outside of the Champion's Room Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
174
Maximum Estimated Cost:
174
Record Number
1167
Priority:
Commons or Lunch Area Finding:
The knee space at the table in the outdoor dining area is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Picnic Table South of the Administration Office Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 1157
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 523 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The picnic tables are nonaccessible by design.
Alternative Rec: (Where Available)
*
Picnic Tables in the Grandstands Full Rec
Modify or replace one of the tables in the Grandstands to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
174
Maximum Estimated Cost:
174
Record Number
1176
Priority:
Commons or Lunch Area Finding:
There is no accessible route to the picnic tables in the outdoor dining area next to L-1.
Alternative Rec: (Where Available)
*
Picnic Tables Next to L-1 Full Rec
Install a 48-inch wide path to the picnic tables in the outdoor dining area that provides a smooth, stable, firm and slip resistant surface. Provide a maneuvering space sufficient to provide a 60-inch diameter turning radius adjacent to at least one of the picnic tables in the outdoor dining area.
Citation
ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
4' x 60'
Minimum Estimated Cost:
1440
Maximum Estimated Cost:
1440
Record Number
219
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 524 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The tables at the outdoor dining area next to L-1 are nonaccessible by design.
Alternative Rec: (Where Available)
*
Picnic Tables Next to L-1 Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
174 174 220
Priority:
Commons or Lunch Area Finding:
The height of the concession counter at the east end of the Stockton Motorplex is greater than 36 inches.
Alternative Rec: (Where Available)
*
Stockton Motorplex Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 347
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 525 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The height of the bar counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Winners Gaming and Sports Emporium Full Rec
Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).
Citation
CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
348
Maximum Estimated Cost:
348
Record Number
346
Priority:
Commons or Lunch Area Finding:
The height of the bar counter in the Champion's Room at the Winner's Gaming and Sports Emporium is greater than 34 inches.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Lower the bar counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).
Citation
CBC 1122B.4; ADAAG 4.32.4; ADAAG 5.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 1158
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 526 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
The knee space at the tables in the outdoor dining area is less than 19 inches deep.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Modify or replace one of the tables in the outdoor dining area to provide knee clearance of at least 27 inches in height, 30 inches in width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure 45). The table top height shall not exceed 34 inches above the finished floor.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
174
Maximum Estimated Cost:
174
Record Number
1159
Priority:
Commons or Lunch Area Finding:
The height of the grill food service counter is greater than 34 inches.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Lower the food service counter to a height between 28 inches and 34 inches from the finished floor (see CBC 1122B.4 and ADAAG 4.32.4).
Citation
CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
348 348 1161
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 527 of 542
Facility Name: San Joaquin Fairgrounds Commons or Lunch Area Finding:
There are no compliant accessible seating areas.
Alternative Rec: (Where Available)
*
Winner's Gaming and Sports Emporium Full Rec
Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.
Citation
CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
237
Maximum Estimated Cost:
237
Record Number
1169
Priority:
Assembly Areas Finding:
There is no compliant wheelchair seating at the Speedway bleachers.
Alternative Rec: (Where Available)
*
Delta Speedway Full Rec
Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.
Disability Access Consultants, Inc.
(800) 743-7067
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1180
Priority:
Page 528 of 542
Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:
The width of the benches in each locker room is less then 24 inches. The length of the benches in each locker room is less then 48 inches. The height of the benches in each locker room is greater than 19 inches.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
Install at least one bench with dimensions of 24 inches in width by 48 inches in length fixed to the wall along the longer dimension in each locker room. Mount the bench 17 inches to 19 inches above the finished floor with ADAAG 4.35.4 in each locker room. Provide sufficient clear floor space alongside the bench to allow a person using a wheelchair to make a parallel transfer onto the bench.
Citation
ADAAG 4.35.4
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
500
Maximum Estimated Cost:
500
Record Number
1198
Priority:
Locker Rooms Finding:
The height of the coat hooks in the locker room is greater than 54 inches above the floor surface.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
Remount the coat hooks to a maximum height of 54 inches above the floor surface.
Citation
CBC 1115B.9.2; ADAAG A4.27
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1199
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 529 of 542
Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:
Showers are provided, there are no accessible showers in the Jockey's Quarters.
Alternative Rec: (Where Available)
*
Jockey's Quarters Full Rec
Since open showers are provided in the locker room, at least one accessible shower is required. Install an accessible shower in one of the corners with L-shaped grab bars extending along the two walls with a folding seat adjacent to the shower controls in the locker room (see CBC 1115B.6.3 and ADAAG 4.21).
Citation
CBC 1115B.6.3; ADAAG 4.21
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
3260
Maximum Estimated Cost:
3260
Record Number
1204
Priority:
Locker Rooms Finding:
This sauna is not accessible and cannot be easily altered. There is not sufficient clear floor space in the sauna to accommodate an individual in a wheelchair.
Alternative Rec: (Where Available)
*
Sauna in the Jockey's Quarters Full Rec
Consult a design professional to modify the sauna. One or more walls may need to be moved to provide sufficient clear floor space to inscribe a 60-inch diameter turning radius in the sauna to accommodate an individual in a wheelchair.
Citation
CBC 1115B.7.2; ADAAG 4.16.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1203
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 530 of 542
Facility Name: San Joaquin Fairgrounds Locker Rooms Finding:
The soap dish is mounted at a height greater than 40 inches above the shower floor.
Alternative Rec: (Where Available)
*
Women's Restroom at Horse Barn 3 Full Rec
Relocate the soap dish mounted in the shower compartment designated to be accessible in the restroom so that it is mounted on the same wall as the water controls at a maximum height of 40 inches above the shower floor (see CBC 1115B.6.2.4.6).
Citation
CBC 1115B.6.2.4.6
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
277
Maximum Estimated Cost:
277
Record Number
1202
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
Bleachers Between L-2 and L-3 Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1187
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 531 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
Bleachers Next to L-1 Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1194
Priority:
Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
Bleachers Next to L-1 Full Rec
Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
107 107 1195
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 532 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
Bleachers South of L-5 Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1192
Priority:
Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter at L-5 indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
Bleachers South of L-5 Full Rec
Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
107 107 1193
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 533 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter at the Delta Speedway or the Grandstands indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
Delta Speedway Full Rec
Post signage at each ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
107 107 1179
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The height of the concession counter at the east end of the Delta Speedway is greater than 36 inches.
Alternative Rec: (Where Available)
*
Delta Speedway Full Rec
Lower the concession counter to a height between 28 inches and 36 inches above the ground level (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1181
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 534 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
The height of the ticket counter at the west end of the Delta Speedway is greater than 36 inches. The counter is a protruding object.
Alternative Rec: (Where Available)
*
Delta Speedway Full Rec
Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1182
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The press box above the stadium is stair-access only and is not accessible to individuals with mobility impairments.
Alternative Rec: (Where Available)
There are ways to provide access to the programs, services and activities at the press box without installing accessible vertical means to the press box area, to include electronic relay devices with electronic visual components (video camera or television) that offer the equivalent sight line provided from inside the press box. The electronic relays may be cabled to an accessible location where individuals with mobility impairments can access.
Full Rec
In most instances, press boxes are built and used by volunteers and the public, which mandates that access for individuals with disabilities be provided. This is difficult in most situations with the location of the press box usually located high above the assembly area. Vertical access may include installing an exterior enclosed platform lift or installing an equivalent press box at ground level with electronic relay devices and equipment that would provide the same line of sight viewing capability as that in the elevated press box.
Delta Speedway Citation Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1208
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 535 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
The height of the ticket counter at the entrance to the Grandstands is greater than 36 inches.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1184
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The press box above the stadium is stair-access only and is not accessible to individuals with mobility impairments.
Alternative Rec: (Where Available)
There are ways to provide access to the programs, services and activities at the press box without installing accessible vertical means to the press box area, to include electronic relay devices with electronic visual components (video camera or television) that offer the equivalent sight line provided from inside the press box. The electronic relays may be cabled to an accessible location where individuals with mobility impairments can access.
Full Rec
In most instances, press boxes are built and used by volunteers and the public, which mandates that access for individuals with disabilities be provided. This is difficult in most situations with the location of the press box usually located high above the assembly area. Vertical access may include installing an exterior enclosed platform lift or installing an equivalent press box at ground level with electronic relay devices and equipment that would provide the same line of sight viewing capability as that in the elevated press box.
Grandstands Citation Minimum Quantity
1
Maximum Quantity:
1
Unit:
Custom
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1196
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 536 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
There is no compliant accessable seating areas at the Grandstand Bleachers.
Alternative Rec: (Where Available)
*
Grandstands Full Rec
Provide compliant accessible wheelchair seating that will provide viewing positions with a line of sight comparable to those of the general public (see ADAAG 4.1.3(19) and ADAAG 4.33.2). At least one companion fixed seat complying with ADAAG 4.33.3 should be provided next to each wheelchair seating space. Readily removable seats may be installed in wheelchair spaces when the spaces are not required to accommodate wheelchair users (see CBC 1104B.3.7 and ADAAG 4.1.3(19). Where total seating capacity exceeds 300, accessible wheelchair seating spaces shall be provided in more than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Each accessible seat shall be marked as accessible.
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
237
Maximum Estimated Cost:
237
Record Number
1197
Priority:
Outdoor Sports Areas and Playgrounds Finding:
There is stair access only to the bleachers. The surface under the bleachers is concrete. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
L-1 Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1188
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 537 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter at L-1 indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
L-1 Full Rec
Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost:
107
Maximum Estimated Cost:
107
Record Number
1189
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The surface under the bleachers is concrete. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
L-3 Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1185
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 538 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter at L-3 indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
L-3 Full Rec
Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
107 107 1186
Priority:
Outdoor Sports Areas and Playgrounds Finding:
The grass surface of the soccer field at the facility prevents access to individuals with mobility impairments.
Alternative Rec: (Where Available)
*
Soccer Field Full Rec
Provide an accessible route to the soccer field area where programs, services and activities are provided. The minimum width of the path of travel is 48 inches with 60 inch by 60 inch passing spaces provided every 200 feet. No protruding objects are permitted on the accessible path of travel. Accessible surfaces shall be firm, stable and slip resistant.
Citation
CBC 1104B.1.2; CBC 1124B.1; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
30 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
360 360 1205
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 539 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
There is stair access only to the bleachers. The surface under the bleachers is asphalt. No wheelchair seating is provided next to the bleachers.
Alternative Rec: (Where Available)
*
Stockton Motorplex Full Rec
Provide accessible wheelchair seating areas adjacent to the bleachers with equivalent line of sight as provided to members of the general public, if technically feasible; otherwise provide accessible wheelchair seating areas adjacent to the bleachers where unobstructed sight lines can be provided (see CBC 1104B.4 and ADAAG 4.33.3). The wheelchair seating area should be outlined, and have the International Symbol of Accessibility to reserve it for wheelchair users.
Citation
CBC 1104B.4; ADAAG 4.33
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
237 237 1190
Priority:
Outdoor Sports Areas and Playgrounds Finding:
There is no signage at the ticket counter at the Stockton Motorplex indicating the availability of accessible seating.
Alternative Rec: (Where Available)
*
Stockton Motorplex Full Rec
Post signage at the ticket counter indicating the availability and location of accessible seating areas (see CBC 1104B.3.4.1).
Citation
CBC 1104B.3.4.1; ADAAG 4.1.3(19)
Minimum Quantity
1
Maximum Quantity:
1
Unit:
Each
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
107 107 1191
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 540 of 542
Facility Name: San Joaquin Fairgrounds Outdoor Sports Areas and Playgrounds Finding:
The height of the ticket counter next to Buildings 2 and 3 is greater than 36 inches.
Alternative Rec: (Where Available)
*
Ticket Counter Next to Buildings 2 and 3 Full Rec
Lower the ticket counter to a height no greater than 36 inches above the floor/ground (see ADAAG 7.2).
Citation
ADAAG 7.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
3 Linear Feet
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
129 129 1183
Priority:
Emergency Warning Systems Finding:
The facility shall have a fire and life safety emergency plan that specifically addresses the evacuation of individuals with disabilities.
Alternative Rec: (Where Available)
*
Full Rec
A fire and life safety emergency plan that specifically addresses the evacuation of individuals with disabilities must comply with CFC Part 9 and CBC 1114B.2 for areas of rescue assistance.
Citation
CFC Part 9 & CBC 1114B.2
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost:
0
Maximum Estimated Cost: Record Number
0 1206
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 541 of 542
Facility Name: San Joaquin Fairgrounds Emergency Warning Systems Finding:
There are visual warning devices in the Winners Gaming and Sports Emporium, though no visual warning devices are located elsewhere in the facility.
Alternative Rec: (Where Available)
Altering a facility's programs, or addressing higher priority barriers can reduce or eliminate the need for an area of rescue assistance, such as making certain that an individual with a disability participates in programs located near an already accessible exit. Otherwise creating an accessible exit can provide an acceptable alternative to providing an area of rescue assistance.
Full Rec
Install visual warning devices integrated with the facility's alarm system complying with CBC 1114B.2.5, ADAAG 4.1.3(14) and ADAAG 4.28 throughout the facility.
Citation
CBC 1114B.2.4; ADAAG 4.1.3(14); ADAAG 4.28
Minimum Quantity
1
Maximum Quantity:
1
Unit:
None Selected
Minimum Estimated Cost: Maximum Estimated Cost: Record Number
0 288 1207
Priority:
Disability Access Consultants, Inc.
(800) 743-7067
Page 542 of 542