PARC IV & PARC V CONDOMINIUMS Houston, Texas

MTEC Exhibit E01 – 26Mar09 Parc IV Condominium Tower SW Corner – Looking NE

MTEC Exhibit E03 – 26Mar09 Parc V Condominium Tower West Elevation – Looking East

Moisture Technology Corporation

M\TEC Project 09495.01 Page 01 of 18

MTEC Exhibit E02 – 26Mar09 Parc IV Condominium Tower SE Corner – Looking NW

MTEC Exhibit E04 – 26Mar09 Parc V Condominium Tower NE Corner – Looking SW

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 01Page of 1002 of 18

MTEC Exhibit E05 – 20Mar09 Parc IV Condominium Tower Main Roof Level North End – Looking West

MTEC Exhibit E06 – 20Mar09 Parc IV Condominium Tower Main Roof Level East Side – Looking North Moisture Technology Corporation

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 01Page of 1003 of 18

MTEC Exhibit E07 – 20Mar09 Parc IV Condominium Tower Main Roof Level East Side – Looking South

MTEC Exhibit E08 – 20Mar09 Parc IV Condominium Tower Main Roof Level West Side – Looking South Moisture Technology Corporation

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 04 of 18

MTEC Exhibit E09 – 26Mar09 Parc IV Condominium Tower South End – Looking East

MTEC Exhibit E10 – 26Mar09 Roof Patch made with Felt Paper and ColdProcess Adhesive with Coating. South End of Main Roof Level Moisture Technology Corporation

MTEC Exhibit E11 – 26Mar09 M\TEC Sample No. IV-04 at Roof Patch made with Felt Paper and Cold-Process Adhesive. South End of Main Roof Level Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 05 of 18

MTEC Exhibit E12 – 26Mar09 Parc IV Cooling Tower West Side – Looking South

MTEC Exhibit E13 – 26Mar09 Water perpetually stands on Main Roof Level at Parc IV Cooling Tower Moisture Technology Corporation

MTEC Exhibit E14 – 26Mar09 Water perpetually stands on Main Roof Level at Parc IV Cooling Tower Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 01Page of 1006 of 18

MTEC Exhibit E15 – 20Mar09 Parc IV Condominium Tower Penthouse Roof Level North End – Looking North

MTEC Exhibit E16 – 20Mar09 Parc IV Condominium Tower Penthouse Roof Level South End – Looking South Moisture Technology Corporation

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 07 of 18

MTEC Exhibit E17 – 26Mar09 Parc IV Condominium Penthouse Roof Level Note loose Vent Stack to the left which represents probable wind damage.

MTEC Exhibit E18 – 26Mar09 Parc IV Condominium Penthouse Roof Level Note missing Hood which represents probable wind damage.

MTEC Exhibit E19 – 26Mar09 Parc IV Condominium Penthouse Roof Level M\TEC Core Sample No. IV-05 – Note interply delamination and presence of water.

MTEC Exhibit E20 – 26Mar09 Parc IV Condominium Penthouse Roof Level M\TEC Core Sample No. IV-05 – Note interply delamination and water on concrete deck.

Moisture Technology Corporation

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 08 of 18

MTEC Exhibit E21 – 26Mar09 Parc IV Condominium Main Roof Level Childress Engineering Wind-uplift Test 01 is location for M\TEC Core Sample No. IV-01.

MTEC Exhibit E22 – 26Mar09 M\TEC Core Sample No. IV-01 Lamination to Concrete Deck and Interply Lamination are acceptable.

MTEC Exhibit E23 – 26Mar09 Parc IV Condominium Main Roof Level Childress Engineering Wind-uplift Test 02 is location for M\TEC Core Sample No. IV-02.

MTEC Exhibit E24 – 26Mar09 M\TEC Core Sample No. IV-02 Lamination to Concrete Deck is marginally acceptable and Interply Lamination is acceptable.

Moisture Technology Corporation

Copyright March 2009

PARC IV & PARC V CONDOMINIUMS Houston, Texas

M\TEC Project 09495.01 Page 09 of 18

MTEC Exhibit E25 – 26Mar09 M\TEC Core Sample No. IV-03 Lamination to Concrete Deck is marginally acceptable and Interply Lamination is acceptable.

MTEC Exhibit E26 – 26Mar09 Finished M\TEC Core Sample No. IV-03 at East Side of Main Roof Level.

MTEC Exhibit E27 – 26Mar09 M\TEC Core Sample No. IV-04 Lamination to Concrete Deck is questionable and Interply Delamination is present. acceptable.

MTEC Exhibit E28 – 26Mar09 Finished M\TEC Core Sample No. IV-04 at South End of Main Roof Level.

Moisture Technology Corporation

Copyright March 2009