For Salmonella enteritidis Results Negative

Positive

Intended Use

Product Specifications

The Reveal for Salmonella enteritidis (Se) Test System provides for the rapid recovery of Salmonella enterica serovar enteritidis in food, layer or broiler house environments and animal feed, allowing detection and presumptive indentification of the target organism.

Sensitivity:

1-10 CFU/25 g

Testing time:

15 minutes (after 48 hour enrichment)

Tests per kit:

20

The Test

Materials Required But Not Provided

To perform the test, a portion (120 µL) of the enrichment culture is placed into the sample port of the test device. The sample flows through the lateral flow device, providing distinct, visible results. If a line develops only in the control zone, the sample is negative for Salmonella enteritidis. If lines are present in the control and test zones, the sample is presumptively positive for Salmonella enteritidis.

Available from Neogen* 1. Two incubators or water baths capable of maintaining 35°C ± 1° and 42°C ± 0.2°. 2. Weigh scale 3. Timer 4. Stomacher®-type bags 5. Pipette pump or bulb 6. 10 mL pipettes 7. Heating source 8. Disposable glass tubes

Test Procedure 1. 2.

Pre-enrich sample. After incubation, transfer 1 mL of the pre-enrichment into 10 mL of Tetrathionate Broth (TT Broth). 3. Transfer 0.1 mL of the pre-enrichment to 10 mL of RappaportVassilliadis Medium (RV Medium). 4. Incubate the TT Broth and the RV medium 24 ± 2 hours at 42°C ± 0.2°. 5. Remove liquid samples from each tube and cool to room temperature. 6. Place 5 free falling drops (120 µL) from each sample into the sample ports of their corresponding test devices (one for each). 7. Read and record results after 15 minutes. 8. If one or both test devices display positive results, then the test is presumptively positive for Salmonella enteritidis. See package insert for complete instructions

Not available from Neogen 1. Brilliant green dye 2. Iodine 3. Stomacher 400 machine or equivalent * See Equipment and Accessories, pages 91–95

Ordering Information Prod.# 9719

52

9590

Product description Reveal for Salmonella enteritidis (Se) Test System contains 20 Reveal for Se test devices and 20 disposable transfer pipettes. Reveal® AccuScan™ Reader

7241

Tetrathionate (TT) Broth Base

7411

Rappaport-Vassilliadis (RV) Medium

Sales & Service: 800/234-5333 (USA/Canada) or 517/372-9200 • Fax: 517/372-2006 • www.neogen.com