Rc Beam Design2 (cantilever)

  • June 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Rc Beam Design2 (cantilever) as PDF for free.

More details

  • Words: 617
  • Pages: 6
Proj. Name: Location: Client: Designer: Date:

2 - Storey Resd'l. Lolita Village, Brgy. Caibaan, Tac. City Pitao BL Pitao BL 2/7/2008

General Description: Cantililever Beam 1.5 m span

DOUBLE REINFORCED CANTILEVER BEAM (WSD) AT END - SPAN NEGATIVE MOMENT DESIGN DATA FOR CONCRETE BEAMS: 13.79 ITEM fc' = 2,000.00 fc = .45fc' 6.21 Es 200,000.00 17,564.80 Ec = 4730√fc' n = Es/Ec 11.00 k = n/(n+fs/fc) 0.2481 j = 1 - k/3 0.92 Given: fc': 3,000.00 psi fc = 1,350.00 psi 9.308 mpa fs = 30,000.00 psi 206.85 mpa Concrete Covering: Top = 35 Bottom = 25

17.2 2,500.00 7.74 200,000.00 19,616.67 10.00 0.2723 0.91 Span L: Beam Section: b d Slab Thickness: Slab Width : Wall Ht. : Wall Thk.:

20.7 3,000.00 9.32 200,000.00 21,520.20 9.00 0.2884 0.90 1.5 150 250 0.1 3 1 0.13

mpa psi mpa mpa

meters mm mm meters meters meters meters

DEADLOAD: 1/2L

BEAM : SLAB : WALL : SIESMIC:

LIVELOAD: TOTAL LOAD: W =

1.94

DESIGN MOMENT: Md =

0.883 Kn / m 3.546 Kn / m 1.530 Kn / m 0.877 Kn / m 5.82 Kn / m 12.657 Kn / m WL^2/2

14.239

Kn - m

IF: M1 < Md: THEREFORE : PROVIDE COMPRESION BARS IF: fs' < fs USE: COMPUTED fs' TRY: Tension Compression

No. of Bars 2.00 1.00 2.00 -

Bar Diameter 16 12 16 12

va
Unit mm mm mm mm

Area 201.06 113.10 201.06 113.10

sq.mm. sq.mm. sq.mm. sq.mm.

Total Area 402.12 113.10 402.12 -

SPACING, S =

2Avfv/v'b

3,147.55

ACI CODE: MAX. SPACING, Sm = IF: S>Sm : USE ACI CODE: Sm = D/2

mm 125

mm

125.00

mm

2.00 pcs. 1.00 pcs.

16 mm. dia. RC Bars 12 mm. dia. RC Bars

250 mm 10 mm dia. Stirrups sp. @ 125 mm. o.c.

2.00 pcs. - pcs. 150 mm.

@ End - span

Total Area 515.22 OK, SAFE Kana BAY!!!! 402.12 OK, SAFE Kana BAY!!!!

16 mm. dia. RC Bars 12 mm. dia. RC Bars

Proj. Name: Location: Client: Designer: Date:

2 - Storey Resd'l. Bldg. Lolita Villaga, Brgy./ Caibaan, Tac. City Pitao BL Pitao BL 2/7/2008

General Description: Cantilever Beam 1.5 m span

INVESTIGATION OF DOUBLE REINF. BEAM AT END - SPAN NEGATIVE MOMENT DESIGN DATA FOR CONCRETE BEAMS: 13.79 ITEM fc' = 2,000.00 fc = .45fc' 6.21 Es 200,000.00 17,564.80 Ec = 4730√fc' n = Es/Ec 11.00 k = n/(n+fs/fc) 0.2481 j = 1 - k/3 0.92 Given: fc': 3,000.00 psi fc = 1,350.00 psi 9.308 mpa fs = 30,000.00 psi 206.85 mpa Concrete Covering: Top = 35 Bottom = 25 DEADLOAD: BEAM : 1/2L SLAB : WALL : SIESMIC: LIVELOAD: 1.94 TOTAL LOAD: W = DESIGN MOMENT: Md =

17.2 2,500.00 7.74 200,000.00 19,616.67 10.00 0.2723 0.91 Span L: Beam Section: b d Slab Thickness: Slab Width : Wall Ht. : Wall Thk.:

20.7 3,000.00 9.32 200,000.00 21,520.20 9.00 0.2884 0.90 1.5 150 250 0.1 3 1 0.13

mpa psi mpa mpa

meters mm mm meters meters meters meters

0.883 Kn / m 3.546 Kn / m 1.530 Kn / m 0.877 Kn / m 5.82 Kn / m 12.657 Kn / m WL^2/2

14.239

Kn - m

TRIAL BARS: Tension Tension Compression

No. of Bars 2 1 2

Diameter 12 12 12

mm. mm. mm.

As = As = As' =

Area,mm^2 226.2 IF: Mc > Md : SAFE, KAAYO BAY !!! 113.10 IF: Ms > Md: SAFE, G'YUD NA BAY !!! 226.20

2 pcs. 1 pcs.

12 mm. dia. RC Bars 12 mm. dia. RC Bars

2.00 pcs.

12 mm. dia. RC Bars

250 mm

Md : SAFE, KAAYO BAY !!! Md: SAFE, G'YUD NA BAY !!!

150 mm.

@ End - span

Related Documents